• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 88
  • 68
  • 16
  • 8
  • 7
  • 5
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 208
  • 59
  • 26
  • 26
  • 22
  • 22
  • 20
  • 19
  • 19
  • 19
  • 18
  • 18
  • 17
  • 17
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Repercussões oxi-hemodinâmicas do banho no paciente adulto internado em estado crítico: evidências pela revisão sistemática de literatura / Oxy-hemodynamic effects of bath in adult patients hospitalized in critical condition: evidence for the systematic review of literature

Dalmo Valério Machado de Lima 04 March 2009 (has links)
O banho do paciente em estado crítico constitui uma atividade que exige ordenamento das diversas etapas, dadas as características e peculiaridades. O aparato tecnológico peculiar das unidades de alta complexidade permite a monitoração, mas dificulta o acesso e mobilização do paciente. As repercussões oxi-hemodinâmicas do banho no paciente adulto internado em estado crítico no contexto relativo à etiologia/dano foram investigadas por meio dessa revisão sistemática de literatura, que objetivou identificar a existência de evidências científicas sobre as referidas repercussões naquela população e; verificar a possibilidade de estabelecimento de critérios para indicação do banho em diferentes situações clínicas. Foram considerados estudos primários e secundários com metodologia explícita, sem recorte temporal ou idiomas predeterminados. Os critérios de inclusão envolveram a mensuração de variável hemodinâmica ou oximétrica no decurso do banho de adultos críticos internados em meio hospitalar. Foi utilizada uma adaptação da estratégia PICO, o PIO, donde: P (pacientes, problema) = \"Intensive Care Units\" e variações; I (intervenção) = banho e variações; O (desfecho) = \"Hemodynamic Phenomena\" / \"Oxygen Consumption\" e variações. Foram pesquisadas: as bases eletrônicas CINAHL, DEDALUS; EMBASE, COCHRANE, LILACS, PubMed/MEDLINE; manualmente as bibliotecas das Escolas de Enfermagem da Universidade Federal Fluminense e Federal do Rio de Janeiro; referências cruzadas das publicações e; artigos relacionados do Pubmed e ISI. Os 44597 resultados iniciais das bases eletrônicas foram exportados para um programa de gerenciamento de referências, submetidos a filtros sucessivos, resultando em 23 publicações que, somadas a duas monografias obtidas em bibliotecas convencionais, perfez 25 referências. Após leitura na íntegra e reuniões de consenso foram descartadas 19, totalizando uma amostra de 6 publicações. Resultados explicitaram a baixa publicação sobre a temática, com predomínio de estudos nacionais. Dada a heterogeneidade e fragilidade dos estudos não foi possível um mapeamento consistente de todas as respostas oximéricas e hemodimâmicas importantes para os pacientes em questão. Os desfechos mais abordados foram a saturação venosa mista de oxigênio e o índice cardíaco, representantes respectivos dos segmentos. À exceção da saturação, não se identificaram diferenças importantes quando comparadas aos baselines. A saturação declinou durante o banho e se restabeleceu 30 minutos ao término. Conclui-se que medidas operacionais parecem atuar como fatores de risco: banho em menos de 4 h após a cirurgia cardíaca, posicionamento prolongado em decúbito lateral e tempo de banho superior a 20 minutos ou; fator de proteção: manutenção da temperatura da água em 40°C. Quanto à evidência dos achados, por derivarem de quase-experimentos, foram qualificados em nível C por Oxford e pontuados entre 11 e 18 pelo check list de Downs & Black que, mostrou associação entre maiores pontuações e melhores controles de validades internas. Sugere-se a utilização de estratégias que maximizem os indícios de proteção e de outras que minimizem os indícios de risco / The bath of the patient in critical state is an activity that requires several stages of planning, because of the characteristics and peculiarities. The peculiar technological apparatus of high complexity units allow for monitoring, but difficult access and mobilization of the patient. The oxy-hemodynamic effects of bath in adult patients hospitalized in critical condition in context on etiology / damage were investigated by this systematic review of literature, which aimed to identify the existence of scientific evidence about these impacts on that population and; to verify the possibility of establishment of criteria for baths indication in different clinical situations. Primary and secondary studies with explicit methodology, without clipping on languages or predetermined time were considered. The inclusion criteria involved the measurement of hemodynamic or oxymetric variable during the bath of adults hospitalized in critical care units. It was used an adaptation of the PICO strategy, the PIO, where: P (patients, problem) = \"Intensive Care Units\" and variations, I (intervention) = bath and variations, O (outcome) = \"Hemodynamic Phenomena\" / \"Oxygen Consumption \"and variations. Were investigated: the electronic databases CINAHL, DEDALUS, EMBASE, Cochrane Library, LILACS, PubMed / MEDLINE; manually the libraries of the Nursing Schools of Universidade Federal Fluminense and Universidade Federal do Rio de Janeiro; cross references of publications and; related articles of Pubmed and ISI. The 44,597 initial results of the electronic databases were exported to a program for managing references, submitted to successive filters, resulting in 23 publications which, added to two monographs obtained in conventional libraries, totalize 25 references. After reading full publications and having consensus meetings, 19 studies were discarded, totalizing a sample of 6 publications. Results explained the low publication on the subject, with a predominance of national studies. In view of the fragility and heterogeneity of the studies, it was not possible to do a consistent mapping of all the important oximetric and hemodynamic answers for these patients. The further discussed outcomes were the mixed venous oxygen saturation and heart rate, representatives of the respective segments. With the exception of saturation, it was not identified important differences when compared to the baselines. The saturation declined during the bath and was restored 30 minutes at the end. It is concluded that operational measures seem act as risk factors: bath in less than 4 hours after cardiac surgery, prolonged positioning in lateral decubitus and showers time over 20 minutes or; a protective factor: maintenance of water temperature at 40 ° C. As the findings were derived from quasi-experiments, their evidences were qualified to level C for Oxford and scored between 11 and 18 by the check list of Downs & Black, that showed an association between higher scores and better control of internal validity. It is suggested the use of strategies that maximize the indications of protection and other that minimize the indications of risk
142

Hipotensão pós-exercício resistido em idosos: caracterização e mecanismos / Post-resistance exercise hypotension in elderly

Queiroz, Andreia Cristiane Carrenho 11 February 2010 (has links)
O treinamento resistido (TR) de alta intensidade tem sido recomendado para reverter as alterações musculares promovidas pelo envelhecimento. Porém, o envelhecimento também se associa de aumento da pressão arterial (PA). Uma sessão de TR promove hipotensão pós-exercício em jovens, mas este efeito não está claro em idosos, sendo este o objetivo dessa dissertação. 16 idosos participaram, após 10-12 semanas de TR, de 2 sessões realizadas em ordem aleatória: Controle-C (repouso) e Exercício-E (3 séries, 8 RM, 7 exercícios). A PA, o débito cardíaco (DC), a freqüência cardíaca (FC), a modulação autonômica cardiovascular foram medidos pré e 60 min pós-intervenções e a PA ambulatorial foi medida por 24 h. A PA sistólica e média aumentaram na sessão C e não se modificaram na E, resultando num efeito hipotensor de -6,4±1,9 e -2,9±0,2 mmHg. A PA diastólica e a resistência vascular periférica (RVP) aumentaram de forma similar nas 2 sessões (+2,0±0,7 mmHg e +3,8±0,7 mmHg.min/l), enquanto que o DC e o volume sistólico (VS) diminuíram, e a FC, o duplo produto (DP) e a razão entre as bandas de baixa e alta freqüência da variabilidade do intervalo R-R aumentaram na sessão E (-0,5±0,1 l/min, -9,3±2,0 ml, +3,8±1,6 bpm, +579,3±164,1 mmHg/bpm e +0,71±0,35). Não houve diferença na PA de 24h, mas a FC e o DP permaneceram aumentados por 5,5 h pós-exercício. Assim, uma sessão de TR de alta intensidade teve efeito hipotensor em idosos treinados, que foi mediado pela redução do DC, promovida pela diminuição do VS, que não foi compensada apesar do aumento da FC, induzida pelo aumento da modulação simpática para o coração. O efeito hipotensor não perdurou pelas demais horas, mas o trabalho cardíaco ficou aumentado por até 5,5 h pós-exercício / High-intensity resistance training (RT) is recommended to delay the effects of aging on skeletal muscle. However, aging is also accompanied by blood pressure (BP) increases. Its known that each RT session promotes post-exercise hypotension in young, but this effect wasnt clear in elderly. Thus, this was the aim of the present study. 16 elderly subjects, who were already participating in a RT program, underwent, in a random order, 2 sessions: Control (C) remained seated and Exercise (E) 7 resistance exercises, 3 sets, 8 RM. BP, cardiac output (CO), heart rate (HR) and cardiovascular autonomic regulation were measured before and 60 min after interventions, while ambulatory BP was measured for 24 h. Systolic and mean BP increased in the C, but did not change in the E, resulting in a hypotensive effects of -6.4±1.9 and -2.9±0.2 mmHg, respectively. Diastolic BP and systemic vascular resistance (SVR) increased similarly in both sessions (+2.0±0.7 mmHg and +3.8±0.7 mmHg.min/l), while CO and stroke volume (SV) decreased, and HR, rate-pressure product (RPP) and low to high-frequency ratio of the R-R interval variability only increased in the E (-0.5±0.1l/min, -9.3±2.0ml/beat, +3.8±1.6beat/min, +579.3±164.1 mmHg/beat/min and +0.71±0.35). Ambulatory BP was similar in both sessions, but HR and RPP were increased for 5,5 h after exercise. In conclusion, a session of high-intensity RT promoted post-exercise hypotensive effects in trained elderly. This effect was mediated by a decrease in CO, produced by a reduction in SV that was not compensated besides the increase in HR, promoted by an increase in sympathetic modulation to the heart. The hypotensive effect was not sustained during daily activities, and cardiac work was kept sustained elevated for 5,5 h post-exercise
143

Repercussões oxi-hemodinâmicas do banho no paciente adulto internado em estado crítico: evidências pela revisão sistemática de literatura / Oxy-hemodynamic effects of bath in adult patients hospitalized in critical condition: evidence for the systematic review of literature

Lima, Dalmo Valério Machado de 04 March 2009 (has links)
O banho do paciente em estado crítico constitui uma atividade que exige ordenamento das diversas etapas, dadas as características e peculiaridades. O aparato tecnológico peculiar das unidades de alta complexidade permite a monitoração, mas dificulta o acesso e mobilização do paciente. As repercussões oxi-hemodinâmicas do banho no paciente adulto internado em estado crítico no contexto relativo à etiologia/dano foram investigadas por meio dessa revisão sistemática de literatura, que objetivou identificar a existência de evidências científicas sobre as referidas repercussões naquela população e; verificar a possibilidade de estabelecimento de critérios para indicação do banho em diferentes situações clínicas. Foram considerados estudos primários e secundários com metodologia explícita, sem recorte temporal ou idiomas predeterminados. Os critérios de inclusão envolveram a mensuração de variável hemodinâmica ou oximétrica no decurso do banho de adultos críticos internados em meio hospitalar. Foi utilizada uma adaptação da estratégia PICO, o PIO, donde: P (pacientes, problema) = \"Intensive Care Units\" e variações; I (intervenção) = banho e variações; O (desfecho) = \"Hemodynamic Phenomena\" / \"Oxygen Consumption\" e variações. Foram pesquisadas: as bases eletrônicas CINAHL, DEDALUS; EMBASE, COCHRANE, LILACS, PubMed/MEDLINE; manualmente as bibliotecas das Escolas de Enfermagem da Universidade Federal Fluminense e Federal do Rio de Janeiro; referências cruzadas das publicações e; artigos relacionados do Pubmed e ISI. Os 44597 resultados iniciais das bases eletrônicas foram exportados para um programa de gerenciamento de referências, submetidos a filtros sucessivos, resultando em 23 publicações que, somadas a duas monografias obtidas em bibliotecas convencionais, perfez 25 referências. Após leitura na íntegra e reuniões de consenso foram descartadas 19, totalizando uma amostra de 6 publicações. Resultados explicitaram a baixa publicação sobre a temática, com predomínio de estudos nacionais. Dada a heterogeneidade e fragilidade dos estudos não foi possível um mapeamento consistente de todas as respostas oximéricas e hemodimâmicas importantes para os pacientes em questão. Os desfechos mais abordados foram a saturação venosa mista de oxigênio e o índice cardíaco, representantes respectivos dos segmentos. À exceção da saturação, não se identificaram diferenças importantes quando comparadas aos baselines. A saturação declinou durante o banho e se restabeleceu 30 minutos ao término. Conclui-se que medidas operacionais parecem atuar como fatores de risco: banho em menos de 4 h após a cirurgia cardíaca, posicionamento prolongado em decúbito lateral e tempo de banho superior a 20 minutos ou; fator de proteção: manutenção da temperatura da água em 40°C. Quanto à evidência dos achados, por derivarem de quase-experimentos, foram qualificados em nível C por Oxford e pontuados entre 11 e 18 pelo check list de Downs & Black que, mostrou associação entre maiores pontuações e melhores controles de validades internas. Sugere-se a utilização de estratégias que maximizem os indícios de proteção e de outras que minimizem os indícios de risco / The bath of the patient in critical state is an activity that requires several stages of planning, because of the characteristics and peculiarities. The peculiar technological apparatus of high complexity units allow for monitoring, but difficult access and mobilization of the patient. The oxy-hemodynamic effects of bath in adult patients hospitalized in critical condition in context on etiology / damage were investigated by this systematic review of literature, which aimed to identify the existence of scientific evidence about these impacts on that population and; to verify the possibility of establishment of criteria for baths indication in different clinical situations. Primary and secondary studies with explicit methodology, without clipping on languages or predetermined time were considered. The inclusion criteria involved the measurement of hemodynamic or oxymetric variable during the bath of adults hospitalized in critical care units. It was used an adaptation of the PICO strategy, the PIO, where: P (patients, problem) = \"Intensive Care Units\" and variations, I (intervention) = bath and variations, O (outcome) = \"Hemodynamic Phenomena\" / \"Oxygen Consumption \"and variations. Were investigated: the electronic databases CINAHL, DEDALUS, EMBASE, Cochrane Library, LILACS, PubMed / MEDLINE; manually the libraries of the Nursing Schools of Universidade Federal Fluminense and Universidade Federal do Rio de Janeiro; cross references of publications and; related articles of Pubmed and ISI. The 44,597 initial results of the electronic databases were exported to a program for managing references, submitted to successive filters, resulting in 23 publications which, added to two monographs obtained in conventional libraries, totalize 25 references. After reading full publications and having consensus meetings, 19 studies were discarded, totalizing a sample of 6 publications. Results explained the low publication on the subject, with a predominance of national studies. In view of the fragility and heterogeneity of the studies, it was not possible to do a consistent mapping of all the important oximetric and hemodynamic answers for these patients. The further discussed outcomes were the mixed venous oxygen saturation and heart rate, representatives of the respective segments. With the exception of saturation, it was not identified important differences when compared to the baselines. The saturation declined during the bath and was restored 30 minutes at the end. It is concluded that operational measures seem act as risk factors: bath in less than 4 hours after cardiac surgery, prolonged positioning in lateral decubitus and showers time over 20 minutes or; a protective factor: maintenance of water temperature at 40 ° C. As the findings were derived from quasi-experiments, their evidences were qualified to level C for Oxford and scored between 11 and 18 by the check list of Downs & Black, that showed an association between higher scores and better control of internal validity. It is suggested the use of strategies that maximize the indications of protection and other that minimize the indications of risk
144

Comparação da variação da pressão sistólica e de pulso nas ventilações com pressão e volume controlados: estudo experimental em coelhos / Comparison of systolic and pulse pressure variation during pressure and volume controlled ventilation. Experimental study in rabbits

Fonseca, Eliana Bonetti 07 December 2006 (has links)
Introdução: A Variação da Pressão Sistólica (VPS) e da Pressão de Pulso (VPP) têm sido propostas como métodos efetivos para monitoração hemodinâmica, em predizer a resposta à reposição da volemia durante a ventilação mecânica. A primeira é calculada pela diferença entre a pressão sistólica máxima e mínima em um ciclo respiratório, e composta pela somatória dos componentes delta up e delta down; e a VPP obtida pela diferença entre a pressão sistólica e diastólica também em um ciclo respiratório. O objetivo deste estudo foi avaliar a VPS e seus componentes, e a VPP durante a ventilação com volume (VCV) e pressão (PCV) controlados, em coelhos normovolêmicos ou submetidos à hemorragia controlada. Método: Trinta e dois coelhos foram distribuídos de forma aleatória em quatro grupos: G1-ConPCV, G2-HemPCV, G3-ConVCV e G4-HemVCV. Foram ventilados em PCV ou VCV, com volume corrente entre 10 e 12 ml.kg-1 e freqüência respiratória para manter normocapnia. Nos grupos controle (G1-ConPCV e G3-ConVCV), sangue não foi retirado, e cada momento foi avaliado por 30 minutos (M0, M1 e M2); nos grupos com hemorragia (G2-HemPCV e G4-HemVCV), não houve perda sangüínea em M0, em M1 retirou-se 15% da volemia estimada, assim como em M2, de forma gradual. Os dados foram submetidos à análise de variância para medidas repetidas (ANOVA), sendo considerados significativos para um valor de p<0,05, e apresentados na forma de média e desvio-padrão. Resultados: Não houve diferença em M0 entre os grupos estudados. Em M1, os grupos com perda sanguínea apresentaram maiores variações na VPS, em seu componente delta down e na VPP, diferindo significativamente apenas dos grupos controle. Quando a volemia foi reduzida em 30% (M2), G4-HemVCV apresentou maior variação na pressão sistólica, no componente delta down e na pressão de pulso; bem como ambos grupos submetidos à hemorragia apresentaram valores significativamente maiores do que os grupos controle. O débito cardíaco não apresentou variação significativa (p>0,05) entre os momentos e grupos estudados. Conclusões: Em coelhos normovolêmicos ou com hipovolemia leve, ambos modos de ventilação se comportam de forma semelhante sobre as variáveis estudadas, ao passo que na hipovolemia moderada pôde-se observar menor comprometimento hemodinâmico durante a PCV / Rationale: Systolic pressure variation (SPV) and pulse pressure variation (PPV) indices have been proposed as effective methods of hemodynamic monitoring to predict fluid responsiveness during mechanical ventilation. SPV is calculated by the difference between the maximum and minimum values of systolic blood pressure following a single positive pressure breath, and it is made up of the sum of their components delta up and delta down; PPV is obtained by the difference between systolic and diastolic blood pressure also in a single positive pressure breath. The purpose of this study was to evaluate SPV and its components, and PPV during volume (VCV) and pressure (PCV) controlled ventilation in normovolemic rabbits or ones submitted to graded hemorrhage. Method: Thirty two rabbits were randomly allocated in four groups: G1- ConPCV, G2-HemPCV, G3-ConVCV and G4-HemVCV. They were ventilated in PCV or VCV; tidal volume was fixed between 10 to 12 mL.kg-1 and respiratory rate was monitored in order to maintain normocapnia. In control groups (G1- ConPCV and G3-ConVCV) blood was not withdrawn and each moment was evaluated for 30 minutes (M0, M1 and M2); in hemorrhage groups (G2-HemPCV and G4-HemVCV) there was no blood loss in M0; in M1 and M2 15% of estimated volemia was graded withdrawn. Data were submitted to analysis of variance for repeated measures (ANOVA); significance level was p<0,05 and results were expressed as mean ± standard deviation. Results: In M0, no significant differences were observed among all groups. Hemorrhagic groups (G2-HemPCV and G4-HemVCV) presented higher SPV, delta down and PPV in M1, differing significantly (p<0,05) only from control groups. When 30% of estimated blood volume was removed, higher SPV, delta down and PPV were observed mainly in G4-HemVCV. Cardiac output did not vary significantly (p>0,05) among groups and moments. Conclusions: In rabbits with normovolemia or slight hemorrhage, both modes of ventilation had similar behavior over studied parameters, while in the ones undergoing moderate hemorrhage PCV determined less hemodynamic compromising
145

Design and evaluation of a portable device for the measurement of bio-impedance cardiography

Shi, Qinghai, Heinig, Andreas, Kanoun, Olfa 29 March 2011 (has links) (PDF)
Electrical impedance of biological matter is known as electrical bio-impedance or simply as bio-impedance. Bio-impedance devices are of great value for monitoring the pathological and physiological status of biological tissues in clinical and home environments. The technological progress in instrumentation has significantly contributed to the progress that has been observed during the last past decades in impedance spectroscopy and electrical impedance cardiograph. Although bio-impedance is not a physiological parameter, the method enables tissue characterization and functional monitoring and can contribute to the monitoring of the health status of a person. In this paper an inexpensive portable multi frequency impedance cardiograph device based on impedance spectroscopy technique has been developed. By means of this system the basic thoracic impedance range and the heart-action-caused changes of impedance can be measured and the hemodynamic parameters of the heart function can be determined. This system has small size and low current consumption. The impedance cardiograph signals of the electrodes configuration by Sramek, Penney and Qu in this work was measured; compared and summarized. The differences of the measuring method, the schematic circuit diagram, the measurement results and area of application between impedance cardiograph and impedance spectroscopy were discussed and compared. The performance of this sensor-system was evaluated.
146

Identification de facteurs de risque d'insuffisance rénale en trauma

Morris, Judy 04 1900 (has links)
Contexte: la survenue d’IRA chez les patients ayant subi un traumatisme est une problématique qui a été peu étudiée jusqu’à ce jour. La présence de cette atteinte rénale a été démontrée comme étant associée à un risque accru de morbidités et de mortalité chez les sujets atteints. Objectifs: identifier les facteurs prédictifs d’insuffisance rénale ou plus récemment appelée atteinte rénale dans cette population particulière et tenter de trouver des facteurs qui peuvent être mesurés dans les premières heures de la prise en charge du patient. Aussi, nous avons cherché à savoir si l’injection de produit de contraste est associée à un risque accru d’insuffisance rénale aiguë dans cette population. Méthodes et résultats: la recherche a eu lieu à l’Hôpital du Sacré-Coeur de Montréal, un centre de traumatologie tertiaire en milieu urbain. Nous avons utilisé le registre des patients hospitalisés en traumatologie dans notre centre hospitalier entre 2002 et mars 2007 de même que les banques de données de laboratoire et de radiologie pour obtenir les données sur la créatinine et les examens avec produits de contraste. Finalement, une revue de dossiers structurée fut conduite pour recueillir le reste de l’information requise. L’incidence d’IRA dans la population étudiée est estimée à environ 5 %. Une analyse cas témoins fut conduite pour identifier les facteurs prédictifs d’IRA. Quarante-neuf cas d’IRA diagnostiqués par le médecin traitant et 101 témoins sélectionnés au hasard ont été analysés. Les facteurs prédictifs suivants ont été identifiés à l’analyse univariée : la première valeur de créatinine obtenue (p<0,001), l’instabilité hémodynamique (p<0,001), les antécédents d’insuffisance rénale chronique tels que notés dans le dossier par le médecin traitant (p=0,009), une maladie cardiaque (p=0,007), une chirurgie dans les 48 premières heures suivant le traumatisme (p=0,053), le niveau de gravité du traumatisme (Injury Severity Score) (p=0,046) et l’injection de produit de contraste au cours des 48 heures suivant le trauma (p=0,077). Parmi ces facteurs, deux ont été identifiés comme prédicteurs indépendants d’IRA à l’analyse multivariée. Une des valeurs était la première valeur de créatinine obtenue RC = 6,17 (p<0,001, IC95 % 2,81 – 13,53) pour chaque augmentation de 0.5mg/dL de créatinine. L’autre facteur était la présence d’instabilité hémodynamique RC 11,61 (p<0,001, IC95 % 3,71 – 36,29). Conclusion: des informations obtenues tôt dans la prise en charge du patient permettent de prédire le risque d’IRA chez ces patients. L’administration de contraste (intraveineuse ou intra-artérielle) ne s’est pas avérée un facteur indépendant de prédiction d’insuffisance rénale aiguë dans cette population dans le modèle multivarié. / Background: acute kidney injury (AKI) has important mortality and morbidity complications. Few studies have looked at predictors of acute renal failure in a trauma patient population. Objectives: we sought to identify factors associated with AKI that can be assessed in the early hospital stay of trauma patients. We also specifically assessed if the administration of radiological contrast was a predictor of AKI. Methods: we conducted a nested case-control study from the trauma registry of an urban Level I trauma center which includes data on more than 6 000 subjects. The cases consisted of 49 patients with a diagnosis of AKI by their treating physician in the first 7 days following their trauma between 2002 and 2007 (March 2007). The controls were randomly selected for a 1:2 case to control ratio. Data were retrieved from the prospective trauma registry database. Additional data were also obtained via the hospital laboratory and radiology databases. Finally, a structured chart review was conducted to obtain the remaining information. Univariate analyses were conducted. Elements with a significance level of <0.1 were included in a multivariate logistic regression model. Results: predictors identified in the univariate analysis were: the first creatinine value obtained (p<0,001), hemodynamic instability (p<0,001), history of coronary artery disease (p=0,007), history of chronic renal insufficiency as per physician’s diagnosis in the chart (p=0,009), surgery in the 48 hours following the trauma (p=0,053), and, injection of contrast in the 48 hours following the trauma (p=0,077). In the final multivariate model, two factors were statistically significant. One factor was the first creatinine value p<0,001, OR 6,17 CI95 % (2,81 – 13,53) for each increase of creatinine by 0,5mg/dL. The other factor was the presence of hemodynamic instability p<0,001 OR 11,61 CI95 % (3,71 – 36,29). Conclusion: easily obtained information in the emergency department can aid in predicting the risk of AKI in a trauma population. Early administration of radiological contrast was not an independant predictor of AKI in this population.
147

Hemodynamická optimalizace u jaterních resekcí / Hemodynamic optimalization in hepatic recection

Zatloukal, Jan January 2017 (has links)
Lowering of central venous pressure in hepatic surgery is nowadays widely recommended and used procedure. Low central venous pressure anesthesia is associated with decreased blood loss and improved clinical outcome. There are several approaches how to reach low central venous pressure. Till now none of them is recommended as superior in terms of patient safety and clinical outcome. Concurrently there is still debate if to use the low central venous pressure anesthesia principle or if it could be replaced with a principle of anesthesia with high stroke volume variation (or another dynamic preload parameter) with the use of a more sophisticated hemodynamic monitoring method. Results of our study didn't show any significant difference between two approaches used for reduction of central venous pressure, but suggest that the principle of low central venous pressure anesthesia could be possibly replaced by the principle of high stroke volume variation anesthesia which presumes the use of advanced hemodynamic monitoring. KEYWORDS Hepatic resection, central venous pressure, Pringle maneuver, hemodynamics, hemodynamic monitoring, fluid therapy, anesthesia
148

Efeitos hemodinâmicos de duas estratégias de ventilação mecânica protetora em um modelo suíno de Síndrome do Desconforto Respiratório Agudo / Hemodynamic effects of two strategies of protective ventilation in porcine model of acute respiratory distress syndrome

Guilherme Buzon Gregores 15 April 2011 (has links)
A Síndrome do Desconforto Respiratório Agudo (SDRA) cursa com insuficiência respiratória e necessidade de ventilação mecânica invasiva (VMI). A mortalidade desta síndrome é elevada, mas pode ser reduzida com o uso de estratégias protetoras de ventilação mecânica que usam baixo de volume corrente (VC), geralmente 6ml/Kg ou menos, para minimizar a lesão causada pelo ventilador. Algumas destas estratégias de ventilação protetora utilizam valores elevados de PEEP que podem produzir instabilidade hemodinâmica. O objetivo deste estudo foi comparar, em um modelo experimental suíno de SDRA, os efeitos hemodinâmicos causados por duas estratégias de ventilação mecânica protetora: uma que utiliza PEEP ajustado pela Tomografia de Impedância Elétrica (OLA) e a outra, a mais comumente utilizada na prática clínica (ARDSNET), em que a PEEP é ajustada através de uma tabela. Foram utilizados 17 animais após randomização (8 no grupo OLA; 9 no grupo ARDSNET) que foram ventilados por 42 horas. As variáveis foram analisadas utilizando ANOVA de medidas repetidas. Antes da radomização, os grupos não apresentavam diferenças nos parâmetros hemodinâmicos e respiratórios. Considerando o período de 42 horas de estudo: 1) o grupo OLA utilizou valores maiores de PEEP, obteve uma melhor oxigenação, mas com valores de PaCO2 mais elevado; não houve diferença entre os grupos para o platô de pressão, mas o delta de pressão foi menor no grupo OLA o que pode minimizar o risco de lesão pulmonar induzida pelo ventilador; 2) o grupo OLA apresentou valores de índice cardíaco (IC) menores durante o estudo, mas não houve um comprometimento aos órgãos alvos conforme pode ser constatado pelos valores normais do lactato arterial e pelos valores de saturação do sangue venoso misto maiores do que no grupo ARDSNET; 3) pela análise de regressão múltipla pode se observar que o aumento da PEEP esteve associado com aumento da pressão média de artéria pulmonar (PMAP), mas redução do IC e da pressão arterial média, enquanto que o aumento da PaCO2 esteve associado com um aumento da PMAP e do IC. Concluímos que uma estratégia ventilatória protetora para SDRA cujo ajuste de PEEP é guiado por TIE, quando comparada com outra estratégia protetora comumente utilizada na prática clínica por um período de 42 horas, determina uso de valores maiores de PEEP, o que melhora a oxigenação e minimiza o delta de pressão, mas causa redução do IC que não resulta em isquemia tecidual. / The Acute Respiratory Distress Syndrome (ARDS) is associated with respiratory failure and need for invasive mechanical ventilation (IMV). The mortality of this syndrome is high, but can be reduced with the use of protective strategies of mechanical ventilation using low tidal volume (VT), usually 6ml/Kg or less, to minimize the damage caused by the ventilator. Some of these strategies of protective ventilation use high levels of PEEP that can produce hemodynamic instability. The aim of this study was to compare, in an experimental pig model of ARDS, the hemodynamic effects caused by two strategies of protective ventilation: one strategy adjusts PEEP values using Electrical Impedance Tomography (EIT-OLA) and the other, the most commonly used in clinical practice (ARDSNET), in which PEEP is adjusted through a table. Seventeen animals were randomized (8 in OLA group; 9 in ARDSNET group) that were ventilated for 42 hours. The variables were analyzed using repeated measures ANOVA. Before randomization, the groups had no difference in hemodynamic and respiratory parameters. Considering the period of 42 hours of study: 1) OLA group used higher values of PEEP, had a better oxygenation but with higher values of PaCO2; there was no difference between groups for the plateau pressure, but the delta pressure was lower in OLA group which can minimize the risk for ventilator-induced lung injury; 2) the OLA group showed lower values of cardiac index (CI) during the study, but there was no damage to target organs as showed by normal blood lactate values and values of mixed venous blood saturation greater than in ARDSNET; 3) multiple regression analysis revealed that, increasing PEEP was associated with increasing in mean pulmonary artery pressure (MPAP), but reduction CI and mean arterial pressure, while increasing in PaCO2 was associated with an increase in MPAP and CI. We conclude that a protective ventilatory strategy for ARDS whose setting of PEEP is guided by EIT, when compared with other protective strategy commonly used in clinical practice for a period of 42 hours requires the use of higher values of PEEP, which improves oxygenation and minimizes delta pressure, but causes reduction of CI that does not result in tissue ischemia.
149

Terapia hemodinâmica guiada por saturação venosa central contínua em pacientes pediátricos submetidos à cirurgia cardíaca ensaio clínico randomizado / Hemodynamic therapy guided by continuous central venous oxygen saturation in pediatric patients undergoing cardiac surgery: a clinical randomized study

Flavio Mauá Chaves Ferreira 21 May 2018 (has links)
Introdução: A terapia hemodinâmica perioperatória baseada em metas modificou a evolução dos pacientes pediátricos cirúrgicos de alto risco, demonstrando ser eficaz na redução de complicações. O objetivo deste estudo foi avaliar o efeito de um protocolo perioperatório guiado por metas baseado na adequação da saturação venosa central mensurada de forma contínua na perfusão tecidual e nas complicações pós-operatórias de pacientes pediátricos submetidos a cirurgia cardíaca. Métodos: Estudo prospectivo, randomizado, e controlado, realizado no Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina de Universidade de São Paulo(Incor-HCFMUSP). Pacientes pediátricos submetidos a cirurgia cardíaca eletiva foram randomizados para grupo terapia hemodinâmica baseado na monitorização da saturação venosa contínua pelo cateter PediaSat (grupo intervenção) ou para grupo padrão. O grupo intervenção foi tratado no intraoperatório e nas primeiras 24 horas de pós-operatório de acordo com um protocolo guiado por metas, baseado na adequação da saturação venosa central (SvcO2 >= 65% nas cardiopatias acianóticas e >= 55% nas cardiopatias cianóticas). O desfecho primário foi a depuração do lactato nas primeiras 24 horas de pós-operatório. Os desfechos secundários foram a ocorrência de complicações pós-operatórias durante a internação hospitalar (insuficiência renal, vasoplegia, baixo débito cardíaco, arritmia, infecção, sangramento e reoperação), tempo de ventilação mecânica, tempo de uso de inotrópicos e de vasopressores e tempo de internação na unidade de terapia intensiva e no hospital e mortalidade operatória. Também foram analisados dados hemodinâmicos e variáveis de perfusão tecidual dos pacientes no período perioperatório. Resultados: No período de julho de 2014 a março de 2016, 65 pacientes foram incluídos no estudo. O número de pacientes que apresentou depuração dos níveis de lactato maior que 30% foi semelhante nos dois grupos (60% no grupo padrão e 59,4% no grupo intervenção, P=0,919). Não houve diferenças em relação a quantidade de dobutamina ou de transfusão de hemácias entre os grupos durante o protocolo. Em relação aos desfechos secundários, o grupo intervenção apresentou menor tempo de ventilação mecânica em comparação como grupo padrão (24,59 h ± 19,69 vs. 85,63 h ± 86,54, P < 0.001), menor tempo de uso de vasopressor [0 h (0-0) vs. 0 h (0-54), P = 0,021], e menor tempo de internação na unidade de terapia intensiva [6 dias (4-10) vs. 8 dias (6-21), p = 0,030 ]. Não houve diferenças entre os grupos em relação aos outros desfechos. Conclusões: Em crianças submetidas a cirurgia cardíaca, uma estratégia de terapia hemodinâmica guiada tendo como alvo a adequação da saturação venosa central de oxigênio não teve impacto na depuração dos níveis de lactato em 24 horas. Entretanto, a estratégia de terapia hemodinâmica guiada foi associada a redução do tempo de ventilação mecânica, da necessidade de vasopressores e do tempo de internação na unidade de terapia intensiva / Introduction: Perioperative hemodynamic therapy through defined goals improves outcomes in high surgical risk patients. The aim of this study was to evaluate whether the use of a perioperative hemodynamic protocol based on the optimisation of the continuous oxygen central venous saturation reduces complications in children undergoing cardiac surgery. Methods: This was a randomized clinical study, performed at the Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina de Universidade de São Paulo. Pediatric patients undergoing cardiac surgery were randomized to hemodynamic therapy based on continous monitorization of central venous saturation of oxgen through the PediaSat catheter (intervention group) or to usual care group. The intervention group during the intraoperative and in the first 24 hours of postoperative were submitted to a hemodynamic protocol of care based on the optimization of central venous saturation (SvcO2 >= 65% in acyanotic disorders and >= 55% in cyanotic disorders). The primary outcome was lactate clearance in 24 hours of postoperative. Secondary outcomes were postoperative complications during hospital stay (acute kidney injury, vasoplegic shock, low cardiac output syndrome, arrhythmia, infection, bleeding and reoperation), duration of mechanical ventilation, duration of inotropes and vasopressors, length of intensive care unit and hospital stay) and death. We also evaluated hemodynamic data and perfusion tissue markers in patients during perioperative care. Results: In the period of July 2014 to March 2016, 65 patients were included in the study. The number of patients presenting lactate clearance higher than 30% in 24 hours was not different between groups (60.6% in the usual care group and 59.4% in the intervention group, P=0.919). There was no difference between groups in the use of dobutamine and in the number of transfused red blood cells units during the protocol. The intervention group had a lower duration of mechanical ventilation when compared to usual care group (24.59 h ± 19.69 s. 85.63 h ± 86.54, P < 0.001). The intervention group had also lower duration of vasopressor therapy [0 h (0-0) vs. 0 h (0-54), P = 0,021], and reduced length of intensive care unit stay [6 days (4-10) vs. 8 days (6-21), p = 0,030].There was no differences between groups in other outcomes. Conclusions: In pediatric patients undergoing cardiac surgery, a strategy of hemodynamic optimization aiming to adequate central venous saturation of oxygen had no influence in lactate clearance. However, hemodynamic therapy was associated with a lower duration of mechanical ventilation, less needing of vasopressors and shorter length of intensive care unit stay
150

Comparação da variação da pressão sistólica e de pulso nas ventilações com pressão e volume controlados: estudo experimental em coelhos / Comparison of systolic and pulse pressure variation during pressure and volume controlled ventilation. Experimental study in rabbits

Eliana Bonetti Fonseca 07 December 2006 (has links)
Introdução: A Variação da Pressão Sistólica (VPS) e da Pressão de Pulso (VPP) têm sido propostas como métodos efetivos para monitoração hemodinâmica, em predizer a resposta à reposição da volemia durante a ventilação mecânica. A primeira é calculada pela diferença entre a pressão sistólica máxima e mínima em um ciclo respiratório, e composta pela somatória dos componentes delta up e delta down; e a VPP obtida pela diferença entre a pressão sistólica e diastólica também em um ciclo respiratório. O objetivo deste estudo foi avaliar a VPS e seus componentes, e a VPP durante a ventilação com volume (VCV) e pressão (PCV) controlados, em coelhos normovolêmicos ou submetidos à hemorragia controlada. Método: Trinta e dois coelhos foram distribuídos de forma aleatória em quatro grupos: G1-ConPCV, G2-HemPCV, G3-ConVCV e G4-HemVCV. Foram ventilados em PCV ou VCV, com volume corrente entre 10 e 12 ml.kg-1 e freqüência respiratória para manter normocapnia. Nos grupos controle (G1-ConPCV e G3-ConVCV), sangue não foi retirado, e cada momento foi avaliado por 30 minutos (M0, M1 e M2); nos grupos com hemorragia (G2-HemPCV e G4-HemVCV), não houve perda sangüínea em M0, em M1 retirou-se 15% da volemia estimada, assim como em M2, de forma gradual. Os dados foram submetidos à análise de variância para medidas repetidas (ANOVA), sendo considerados significativos para um valor de p<0,05, e apresentados na forma de média e desvio-padrão. Resultados: Não houve diferença em M0 entre os grupos estudados. Em M1, os grupos com perda sanguínea apresentaram maiores variações na VPS, em seu componente delta down e na VPP, diferindo significativamente apenas dos grupos controle. Quando a volemia foi reduzida em 30% (M2), G4-HemVCV apresentou maior variação na pressão sistólica, no componente delta down e na pressão de pulso; bem como ambos grupos submetidos à hemorragia apresentaram valores significativamente maiores do que os grupos controle. O débito cardíaco não apresentou variação significativa (p>0,05) entre os momentos e grupos estudados. Conclusões: Em coelhos normovolêmicos ou com hipovolemia leve, ambos modos de ventilação se comportam de forma semelhante sobre as variáveis estudadas, ao passo que na hipovolemia moderada pôde-se observar menor comprometimento hemodinâmico durante a PCV / Rationale: Systolic pressure variation (SPV) and pulse pressure variation (PPV) indices have been proposed as effective methods of hemodynamic monitoring to predict fluid responsiveness during mechanical ventilation. SPV is calculated by the difference between the maximum and minimum values of systolic blood pressure following a single positive pressure breath, and it is made up of the sum of their components delta up and delta down; PPV is obtained by the difference between systolic and diastolic blood pressure also in a single positive pressure breath. The purpose of this study was to evaluate SPV and its components, and PPV during volume (VCV) and pressure (PCV) controlled ventilation in normovolemic rabbits or ones submitted to graded hemorrhage. Method: Thirty two rabbits were randomly allocated in four groups: G1- ConPCV, G2-HemPCV, G3-ConVCV and G4-HemVCV. They were ventilated in PCV or VCV; tidal volume was fixed between 10 to 12 mL.kg-1 and respiratory rate was monitored in order to maintain normocapnia. In control groups (G1- ConPCV and G3-ConVCV) blood was not withdrawn and each moment was evaluated for 30 minutes (M0, M1 and M2); in hemorrhage groups (G2-HemPCV and G4-HemVCV) there was no blood loss in M0; in M1 and M2 15% of estimated volemia was graded withdrawn. Data were submitted to analysis of variance for repeated measures (ANOVA); significance level was p<0,05 and results were expressed as mean ± standard deviation. Results: In M0, no significant differences were observed among all groups. Hemorrhagic groups (G2-HemPCV and G4-HemVCV) presented higher SPV, delta down and PPV in M1, differing significantly (p<0,05) only from control groups. When 30% of estimated blood volume was removed, higher SPV, delta down and PPV were observed mainly in G4-HemVCV. Cardiac output did not vary significantly (p>0,05) among groups and moments. Conclusions: In rabbits with normovolemia or slight hemorrhage, both modes of ventilation had similar behavior over studied parameters, while in the ones undergoing moderate hemorrhage PCV determined less hemodynamic compromising

Page generated in 0.0324 seconds