• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 188
  • 11
  • 10
  • 10
  • 10
  • 8
  • 5
  • 2
  • Tagged with
  • 194
  • 194
  • 106
  • 106
  • 96
  • 40
  • 39
  • 37
  • 32
  • 28
  • 27
  • 25
  • 22
  • 22
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Avaliação do volume e da vascularização renais ao ultrassom tridimensional em fetos com restrição de crescimento intrauterino / Evaluation of fetal renal volume and vascularization with the threedimensional ultrasound in intrauterine growth restriction

Janaina Campos Senra 21 November 2018 (has links)
INTRODUÇÃO: Na restrição de crescimento intrauterino, a resposta adaptativa a hipóxia, com priorização do fluxo sanguíneo para órgãos nobres, causa vasoconstricção periférica, com aumento da resistência nas artérias renais. Com isso, o desenvolvimento renal é prejudicado e fetos restritos apresentam volumes renais menores. No entanto, a literatura é escassa em estudos que utilizem a ultrassonografia tridimensional na avaliação renal e não descreve a relação desse possível dano renal com desfechos neonatais adversos. Tal técnica tem sido utilizada para mensurar volumes de órgãos e quantificar fluxos sanguíneos de baixa resistência, podendo ser também aplicada para melhorar a avaliação do volume e vascularização renal na restrição de crescimento. OBJETIVOS: Comparar a razão entre o volume renal total e o peso fetal estimado (VRT/PFE) entre fetos com e sem restrição. Além disso, correlacionar o VRT/PFE com a dopplervelocimetria fetal e os índices de vascularização renal e avaliar a associação dos parâmetros renais com eventos neonatais adversos nos fetos restritos. MÉTODOS: O volume total e a vascularização renal de fetos restritos e normais foram avaliados pela ultrassonografia tridimensional e a técnica VOCAL. Os índices de vascularização renal foram corrigidos pela profundidade renal (IVcp, IVFcp and IFcp). Os testes t para amostras independentes e Mann-Whitney foram utilizados para a comparação entre os grupos. Modelos lineares generalizados foram aplicados para avaliar a associação entre as características renais e os eventos neonatais adversos. RESULTADOS: Setenta e um fetos restritos foram comparados a 194 fetos com crescimento normal. O VRT/PFE foi menor no grupo restrito (p < 0,001). Porém essa razão não se correlacionaou com os parâmetros dopplervelocimétricos, os índices vasculares renais ou qualquer evento neonatal adverso. CONCLUSÃO: A razão entre o volume renal total e o peso fetal estimado tende a diminuir na restrição de crescimento intrauterino / INTRODUCTION: In fetal growth restriction, the adaptive response to hypoxia, with prioritization of blood flow to noble organs, causes peripheral vasoconstriction, such as increased resistance in the renal arteries. Then, renal development is impaired and restricted fetuses have lower renal volumes. However, the literature is scarse in studies using three-dimensional ultrasound in renal assessment and does not describe the relationship of this potential renal damage with adverse neonatal outcomes. That technique has been used to mesure volumes and quantify blood flows of low resistance and could also be applied to improve the evaluation of renal volume and vascularization in fetal growth restriction. OBJECTIVES: To compare the ratio of total renal volume to estimated fetal weight (TRV/EFW) among fetuses with and without grown restriction. Fhurthermore, we aim to correlate TRV/EFW with fetal dopplervelocimetry and renal vascularization indexes and to evaluate the association of renal parameters with adverse neonatal events in restricted fetuses. METHODS: Total renal volume and renal vascularization of restricted and normal fetuses were evaluated by three-dimensional ultrasonography and the VOCAL technique. Renal vascularization indexes were corrected for renal depth (VIcd, VFIcd and FIcd). The t-tests for independent samples and Mann-Whitney test were used for comparisons between groups. Generalized linear models were applied to evaluate the association between renal characteristics and adverse neonatal events. RESULTS: Seventy-one restricted fetuses were compared to 194 normally growing fetuses. The TRV/EFW was lower in the restricted group (p < 0.001). However, this ratio did not correlate with Doppler velocimetric parameters, renal vascular indexes or any adverse neonatal events. CONCLUSION: The ratio of total renal volume to estimated fetal weight tends to decrease in intrauterine growth restriction
162

Avaliação da relação entre os índices vasculares placentários e a exposição individual à poluição atmosférica no primeiro trimestre / Evaluation of the placental vascular indices and individual exposure to air pollution in the first trimester

Karen Hettfleisch 17 February 2016 (has links)
OBJETIVO: Avaliar a influência dos efeitos da poluição atmosférica sobre o volume e a vascularização placentários no primeiro trimestre. MÉTODOS: O presente estudo é uma coorte prospectiva  realizada de outubro de 2011 a março de 2014, em São Paulo, Brasil. Os critérios de inclusão foram: feto único, idade gestacional entre 11 semanas e 13 semanas e 6 dias, ausência de doença materna, ausência de malformações e utilização correta do amostrador passivo individual de poluentes. Os critérios de exclusão foram: gestação gemelar, malformações e abortamento diagnosticados à ultrassonografia, mudança de endereço para fora da área de recrutamento, desistência da paciente, doença materna diagnosticada durante o acompanhamento. A exposição à poluição foi avaliada por 7 a 18 dias, antes da avaliação ultrassonográfica, utilizando-se amostrador passivo individual dos poluentes NO2 e de O3. Após uso do filtro, as gestantes eram avaliadas na Clínica Obstétrica do Hospital das Clínicas da Faculdade de Medicina de São Paulo (FMUSP). Nesse local, elas foram submetidas à ultrassonografia morfológica entre 11 semanas e 13 semanas e 6 dias e à avaliação placentária pela técnica tridimensional associada ao power Doppler. Por meio desse exame foram avaliados quantitativamente o volume da placenta e seus índices vasculares placentários (com o software VOCAL), os quais compreendem: índice de vascularização (IV), índice de fluxo (IF) e índice de vascularização e fluxo (IVF). A influência dos níveis de poluentes na vascularização e volume placentários log-transformada foi analisada utilizando modelos de regressão linear múltipla que controlavam a idade gestacional, índice de massa corpórea, tabagismo, localização da placenta e paridade. RESULTADOS: Foram avaliadas 229 gestantes no primeiro. O aumento dos níveis de NO2 no primeiro trimestre teve um efeito negativo significativo sobre o IV (p = 0,012 e beta = 0,160) e IVF (p = 0,015 e beta = -0,159). Não houve influência de NO2 e O3 no volume placentário ou IF. CONCLUSÃO: A exposição materna ao NO2 foi significativamente associada com diminuição do índice de vascularização e do índice de vascularização e fluxo no primeiro trimestre da gravidez, o que sugere que esse poluente e outros poluentes primários e secundários, os quais estão associados ao NO2, influenciam na placentação, reduzindo sua vascularização / OBJECTIVE: To evaluate the influence of air pollution on the volume and placental vascularization in the first trimester. METHODS: This study is a prospective cohort conducted from October 2011 to March 2014 in São Paulo, Brazil. The inclusion criteria were single fetus, gestational age between 11 weeks and 13 weeks and 6 days, the absence of maternal disease, fetal defects and correct use of passive personal monitors pollutants. The exclusion criteria were twin pregnancy, abortion and malformations diagnosed on ultrasound, change of address out of the area of recruitment, patient abandonment, and maternal disease diagnosed during follow-up. The pollution exposure was evaluated by 7 to 18 days, before the ultrasound evaluation, using passive personal monitors pollutants of NO2 and O3. After using the filter, the pregnant women were evaluated at Obstetrics Department from Hospital das Clinicas of Faculdade de Medicina de São Paulo (FMUSP). In this place, they were subjected to morphological ultrasound between 11 weeks and 13 weeks and 6 days and placental evaluation by the three dimensional ultrasound power Doppler. Through the ultrasound examination were quantitatively evaluated the volume of the placenta and their placental vascular indices (with VOCAL software), which comprise the vascularization index (VI), flow index (FI) and vascularization flow index (VFI). The influence of pollutant levels on logtransformed placental vascularization and volume was analyzed using multiple linear regression models that controlled for gestational age, body mass index, smoking status, placental location and parity. RESULTS: In the first trimester 229 pregnant women were evaluation. NO2 levels increased in the first trimester had a significant negative effect on the VI (p=0.012 and beta= -0.160) and the VFI (p = 0.015 and beta= -0.159). No effect of NO2 and O3 on the log of placental volume or FI was observed. CONCLUSION: NO2 exposure was significantly associated with a diminished Vascularization Index and Vascularization and Flow Index in the first trimester of pregnancy, which suggests that this pollutant and other primary and secondary pollutants that are associated with NO2 influence placentation and decrease vascularization
163

Estimativa do peso do recem-nascido por meio de medidas ultrassonograficas bidimensionais e do volume da coxa fetal / Birth weight precition by two-dimensional ultrasound measurements and fetal thigh volume

Bennini Junior, João Renato, 1978- 27 November 2018 (has links)
Orientadores: Cleisson Fabio Andrioli Peralta, Ricardo Barini / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-11-27T11:44:05Z (GMT). No. of bitstreams: 1 BenniniJunior_JoaoRenato_M.pdf: 1809698 bytes, checksum: 399e6ab502353af527e35953428d5e09 (MD5) Previous issue date: 2009 / Resumo: Introdução: Alguns estudos demonstram que a predição do peso fetal usando a volumetria dos membros fetais é mais precisa do que quando se usam medidas bidimensionais (2D). Até hoje, somente o método multiplanar foi utilizado para a volumetria dos membros fetais. Desta forma, a utilidade do método rotacional (VOCAL®) para este fim nunca foi testada. Objetivos: Avaliar as variabilidades intra e interobservadores e a concordância entre as medidas do volume da coxa fetal realizadas com os métodos multiplanar e VOCAL®. Comparar as acurácias das fórmulas com medidas do volume da coxa fetal com as acurácias das fórmulas com medidas 2D. Comparar as acurácias das fórmulas deste estudo com as acurácias das fórmulas já publicadas. Métodos: 210 pacientes foram avaliadas, formando um grupo para gerar as fórmulas (n = 150) e um grupo para validá-las (n = 60). Os pacientes utilizados para gerar as fórmulas também foram utilizados para avaliar as variabilidades intra e interobservadores e a concordância entre as medidas realizadas pelos métodos multiplanar e VOCAL®. Foram utilizadas análises de regressão polinomial para criar uma equação com medidas 2D, uma com o volume da coxa fetal medido pelo método multiplanar (CoxaM) e uma com o volume da coxa fetal medido pelo método VOCAL® (CoxaV). Utilizaram-se testes t de Student pareados para comparar as acurácias das equações deste estudo com as acurácias das fórmulas já publicadas. Foram utilizadas análises proporcionais de Bland e Altman para avaliar as variabilidades intra e interobservadores e a concordância entre as medidas realizadas pelos métodos multiplanar e VOCAL®. Resultados: A diferença média percentual entre as medidas pelos métodos multiplanar e VOCAL® foi de -0,04 com limites de concordância de 95% de -8,17 e 8,09. A diferença média percentual e os limites de concordância de 95% entre as medidas na avaliação das variabilidades intra e interobservadores foram -1,10 (-7,67 to 5,47) e 0,61 (-7,68 to 8,91) para o método VOCAL® e 1,03 (-6,35 to 8,41) e -0,68 (-11,42 to 10,06) para o multiplanar. As melhores fórmulas para cálculo do peso fetal estimado (PFE) foram: PFE = -562.824 + 11.962 x CA x CF + 0,009 x DBP² x CA² (CA: circunferência abdominal; CF: comprimento femoral; DBP: diâmetro biparietal); PFE = 1033.286 + 12.733 x CoxaM; PFE = 1025.383 + 12.775 x CoxaV. Tanto no grupo que gerou as fórmulas como no grupo utilizado para validá-las não houve diferença significativa entre as acurácias das fórmulas com medidas 2D ou tridimensionais (3D). Quando aplicadas nas pacientes deste estudo, as acurácias das fórmulas 2D e 3D já publicadas foram significativamente piores dos que as das novas fórmulas. Conclusões: Os métodos VOCAL® e multiplanar são intercambiáveis para a volumetria da coxa fetal. Possivelmente as maiores fontes de discrepâncias na estimativa do peso fetal são as diferenças fenotípicas entre as pacientes utilizadas para criar as fórmulas. Os dados deste estudo reforçam a necessidade de fórmulas específicas para cada população, independentemente do uso de medidas 2D ou 3D. / Abstract: Introduction: Some authors have demonstrated that the prediction of birth weight using fetal limb volumetry is more precise than with two-dimensional ultrasound (2DUS). To date, only the multiplanar method has been used for fetal limb volumetry, so the usefulness of the rotational technique (VOCALTM - Virtual Organ Computer- aided AnaLysis) for this purpose has never been tested. Objectives: To evaluate the repeatability, reproducibility and agreement of measurements performed with multiplanar and VOCALTM techniques for total fetal thigh volumetry. To compare the accuracies of birth-weight-predicting models with total fetal thigh volumetry with models derived from 2DUS parameters. To compare the performances of our new formulas with those of previously published equations. Methods: 210 patients were prospectively evaluated to compose a formula-generating group (n = 150) and a prospective-validation group (n = 60). The patients of the formula-generating group were also used to evaluate the repeatability, reproducibility and the agreement of the measurements of multiplanar and VOCALTM techiniques for fetal thigh volumetry. Polynomial regression analysis was performed in the formula-generating group to generate one equation with 2DUS measurements, one with fetal thigh volume measured by the multiplanar technique (ThiM) and one with fetal thigh volume obtained by the VOCALTM method (ThiV). Paired samples t-tests were used to compare the accuracies of our equations with those of previously published 2D and three-dimensional (3D) equations. Proportionate Bland and Altman analyses were performed to determine the agreement between the two methods and to evaluate intra- and inter-observer variability. Results: The mean percentage difference between measurements performed with the VOCALTM and multiplanar techniques was -0.04 and the 95% limits of agreement were -8.17 and 8.09. The mean percentage difference and 95% limits of agreement between paired measurements in the assessment of intra- and inter-observer variability were -1.10 (-7.67 to 5.47) and 0.61 (-7.68 to 8.91) for the VOCALTM technique and 1.03 (-6.35 to 8.41) and -0.68 (-11.42 to 10.06) for the multiplanar method. The formulas with the best fit for the prediction of birth weight (EFW) were: EFW = -562.824 + 11.962 x AC x FL + 0.009 x BPD² x AC² (AC: abdominal circumference; FL: femur length; BPD: biparietal diameter); EFW = 1033.286 + 12.733 x ThiM; EFW = 1025.383 + 12.775 x ThiV. For both the formula-generating and the rospective-validation groups, there was no significant difference between the accuracies of the new 2DUS and 3DUS models. When applied to our population, the accuracies of previously published 2DUS and 3DUS formulas were significantly worse than our models. Conclusions: The VOCALTM and multiplanar techniques can be used interchangeably for total fetal thigh volumetry. We believe that the greatest sources of discrepancies in estimation of birth weight are the phenotypic differences among patients used to create each of the formulas mentioned in this study. Our data reinforce the need for customized birth weight prediction formulas, regardless of whether 2DUS or 3DUS measurements are employed. / Mestrado / Tocoginecologia / Mestre em Tocoginecologia
164

Avaliação da relação entre os índices vasculares placentários e a exposição individual à poluição atmosférica no primeiro trimestre / Evaluation of the placental vascular indices and individual exposure to air pollution in the first trimester

Hettfleisch, Karen 17 February 2016 (has links)
OBJETIVO: Avaliar a influência dos efeitos da poluição atmosférica sobre o volume e a vascularização placentários no primeiro trimestre. MÉTODOS: O presente estudo é uma coorte prospectiva  realizada de outubro de 2011 a março de 2014, em São Paulo, Brasil. Os critérios de inclusão foram: feto único, idade gestacional entre 11 semanas e 13 semanas e 6 dias, ausência de doença materna, ausência de malformações e utilização correta do amostrador passivo individual de poluentes. Os critérios de exclusão foram: gestação gemelar, malformações e abortamento diagnosticados à ultrassonografia, mudança de endereço para fora da área de recrutamento, desistência da paciente, doença materna diagnosticada durante o acompanhamento. A exposição à poluição foi avaliada por 7 a 18 dias, antes da avaliação ultrassonográfica, utilizando-se amostrador passivo individual dos poluentes NO2 e de O3. Após uso do filtro, as gestantes eram avaliadas na Clínica Obstétrica do Hospital das Clínicas da Faculdade de Medicina de São Paulo (FMUSP). Nesse local, elas foram submetidas à ultrassonografia morfológica entre 11 semanas e 13 semanas e 6 dias e à avaliação placentária pela técnica tridimensional associada ao power Doppler. Por meio desse exame foram avaliados quantitativamente o volume da placenta e seus índices vasculares placentários (com o software VOCAL), os quais compreendem: índice de vascularização (IV), índice de fluxo (IF) e índice de vascularização e fluxo (IVF). A influência dos níveis de poluentes na vascularização e volume placentários log-transformada foi analisada utilizando modelos de regressão linear múltipla que controlavam a idade gestacional, índice de massa corpórea, tabagismo, localização da placenta e paridade. RESULTADOS: Foram avaliadas 229 gestantes no primeiro. O aumento dos níveis de NO2 no primeiro trimestre teve um efeito negativo significativo sobre o IV (p = 0,012 e beta = 0,160) e IVF (p = 0,015 e beta = -0,159). Não houve influência de NO2 e O3 no volume placentário ou IF. CONCLUSÃO: A exposição materna ao NO2 foi significativamente associada com diminuição do índice de vascularização e do índice de vascularização e fluxo no primeiro trimestre da gravidez, o que sugere que esse poluente e outros poluentes primários e secundários, os quais estão associados ao NO2, influenciam na placentação, reduzindo sua vascularização / OBJECTIVE: To evaluate the influence of air pollution on the volume and placental vascularization in the first trimester. METHODS: This study is a prospective cohort conducted from October 2011 to March 2014 in São Paulo, Brazil. The inclusion criteria were single fetus, gestational age between 11 weeks and 13 weeks and 6 days, the absence of maternal disease, fetal defects and correct use of passive personal monitors pollutants. The exclusion criteria were twin pregnancy, abortion and malformations diagnosed on ultrasound, change of address out of the area of recruitment, patient abandonment, and maternal disease diagnosed during follow-up. The pollution exposure was evaluated by 7 to 18 days, before the ultrasound evaluation, using passive personal monitors pollutants of NO2 and O3. After using the filter, the pregnant women were evaluated at Obstetrics Department from Hospital das Clinicas of Faculdade de Medicina de São Paulo (FMUSP). In this place, they were subjected to morphological ultrasound between 11 weeks and 13 weeks and 6 days and placental evaluation by the three dimensional ultrasound power Doppler. Through the ultrasound examination were quantitatively evaluated the volume of the placenta and their placental vascular indices (with VOCAL software), which comprise the vascularization index (VI), flow index (FI) and vascularization flow index (VFI). The influence of pollutant levels on logtransformed placental vascularization and volume was analyzed using multiple linear regression models that controlled for gestational age, body mass index, smoking status, placental location and parity. RESULTS: In the first trimester 229 pregnant women were evaluation. NO2 levels increased in the first trimester had a significant negative effect on the VI (p=0.012 and beta= -0.160) and the VFI (p = 0.015 and beta= -0.159). No effect of NO2 and O3 on the log of placental volume or FI was observed. CONCLUSION: NO2 exposure was significantly associated with a diminished Vascularization Index and Vascularization and Flow Index in the first trimester of pregnancy, which suggests that this pollutant and other primary and secondary pollutants that are associated with NO2 influence placentation and decrease vascularization
165

Estimativa do volume placentário e da vascularização placentária por meio da ultrassonografia tridimensional em gestação com síndromes hipertensivas / Assessment of placental volume and vascular indices by three-dimensional ultrasonography in pregnancies with hypertensive disorders

Eduardo Jorge de Almeida Pimenta 19 June 2013 (has links)
Objetivo: Estimar o volume placentário e os índices de vascularização placentária em gestantes com síndromes hipertensivas, no segundo e terceiro trimestres gestacionais, e compará-los com os de gestantes sem morbidades (grupo controle). Métodos: Durante o período compreendido entre Abril de 2011 a Julho de 2012, foi realizado estudo clínico, prospectivo caso-controle envolvendo 62 gestantes hipertensas com idades gestacionais compreendidas entre 27 a 38 semanas e 66 gestantes hígidas na mesma faixa de idade gestacional. As gestantes foram submetidas à ultrassonografia para avaliação do volume placentário tridimensional calculado pelo método VOCAL, analisado mediante dois índices placentários, ou seja, volume placentário observado sobre esperado (VP o/e) e relação entre volume placentário sobre peso fetal (VP/PF), e também com quantificação da vascularização placentária por meio dos índices vasculares: índice de vascularização (IV), índice de vascularização e fluxo (IVF) e índice de fluxo (IF), utilizando ultrassom 3D power Doppler. Os critérios de inclusão foram gestações únicas com idade gestacional confirmada à ultrassonografia, sem malformações fetais e com diagnóstico do tipo de hipertensão, realizado segundo os critérios seguidos pelo protocolo assistencial da Clínica Obstétrica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo ou gestações sem complicações clínicas e/ou obstétricas. Foram assim criados dois índices placentários: de volume placentário observado (calculado no exame) sobre a média esperada (percentil 50 da curva de normalidade publicada por de Paula et al.),definido pela sigla VP o/e; e um índice relacionando o volume placentário estimado sobre o peso fetal, definido pela sigla VP/PF; este último com o objetivo de eliminar a influência da variável Idade gestacional. Resultados: Foram incluídas no estudo 62 gestantes hipertensas (grupo estudo) e 66 gestantes hígidas (grupo controle). Do total de pacientes examinadas, 7 ( 5,4 %) foram excluídas: 6 por apresentarem intercorrências clínicas maternas e 1 por óbito fetal. Não houve diferenças estatisticamente significativas entre os índices de volumes placentários (O/E VP e VP/PF) das pacientes do grupo estudo quando comparadas com o grupo controle (p=0,793 e 0,152, respectivamente). Em relação aos índices vasculares placentários, houve redução significativa do IV (p < 0,001) e do IVF (p=0,002), não tendo havido redução nos valores do IF.Em relação a esse índice houve aumento do valor do fluxo, com p=0,006. Conclusão: Os volumes placentários não apresentaram diferenças estatisticamente significativas quando comparados com os de pacientes do grupo controle. Os índices de vascularização placentária (IV, IF e IVF) apresentaram os seguintes resultados: o IV e o IVF se mostraram significativamente menores nas pacientes hipertensas, enquanto o IF não mostrou redução no grupo estudo quando comparados com os do controle / Objectives: Our aim was to estimate placental volumes and vascular indexes in pregnant women with hypertensive syndromes during second and third gestational trimesters, and to compare them with those of healthy pregnant women (control group). Methods: From April 2011 to July 2012 a clinical, prospective, case-control study has been performed with 62 hypertensive pregnant women at gestational age of 27 to 38 weeks and 66 healthy pregnant women at the same gestational age. All pregnant women underwent three-dimensional power Doppler ultrasound examination to assess the placental volumes and vascular indexes: VI (vascularization Index), Vascularization Flow Index (VFI) and Flow Index (FI). The inclusion criteria were single gestation with gestational age confirmed by first trimester ultrasound, without fetal malformations and established diagnosis of hypertension according to criteria used at Obstetrics Department from Hospital das Clinicas of Faculdade de Medicina da Universidade de São Paulo or pregnant women without clinical diseases or obstetrical complications. Two placental volume ratios were created: observed-toexpected placental volume (o/e-PV) and placental volume-to-estimated fetal weight (PV/EFW) aiming to exclude any influence of the gestational age over results. For expected placental volume we used the 50th percentile from placental volume normograms as published by de Paula et al. Results Sixtysix healthy pregnant women and 62 pregnant women with hypertensive disorders were evaluated (matched by maternal age, gestational age at ultrasound exam and parity). Placental volumes were not reduced in pregnancy with hypertensive disorders (p>0.05). Reduced placental VI and VFI were observed in pregnancy complicated with hypertensive disorder (p<0.01 and p<0.01), specially in patients with superimposed preeclampsia (p=0.02 and 0.04). Week correlation was observed between placental volumes, placental vascular indices and Doppler studies of the uterine and umbilical arteries. Conclusion: Placental volumes showed no statistically significant differences when comparing study group with control group. Vascularization indices (VI, FI and VFI) have showed the following results: VI and VFI were significantly lower in hypertensive patients, whilst FI showed no decrease when compared to control group
166

Avaliação do volume orbitário nos avanços frontofaciais / Evaluation of the orbit volume in craniofacial advancements

Antunes, Rodrigo Badotti 09 December 2014 (has links)
Craniofaciossinostose sindrômica (CS) é uma desordem congênita associada às mutações dos genes FGFR1, FGFR2 e FGFR3. Ocasiona uma fusão prematura das suturas craniofaciais, levando à deficiência no crescimento do crânio e terço médio da face. A severidade dos sintomas relacionados à hipertensão intracraniana, aparelho respiratório (síndrome da hipopneia-apneia do sono) e ocular (órbitas rasas, proptose ocular, exorbitismo e falta de proteção do globo ocular), são parâmetros para indicar o procedimento cirúrgico. A tomografia-3D é uma opção atual e pouco utilizada para avaliar os volumes orbitais e a magnitude dos avanços craniofaciais e seus vetores; esse método permite melhor definição das estruturas anatômicas sem distorção das imagens, promovendo uma avaliação adequada dos resultados. Os objetivos do presente estudo foram avaliar os volumes orbitais, os avanços craniofaciais e seus vetores nas osteotomias Le Fort III e Monobloco com uso de aparelhos distratores, a correlação entre os avanços craniofaciais e a variação dos volumes orbitais e determinar a eficácia dos avanços craniofaciais por meio da comparação com índices normais de volumes orbitais. No período de janeiro de 2001 a dezembro de 2012, foram selecionados 20 pacientes submetidos ao alongamento ósseo gradual do terço médio da face, divididos em dois grupos. Grupo LF (n = 9), submetidos à osteotomia Le Fort III e Grupo MB (n = 11), submetidos à osteotomia frontofacial monobloco. A avaliação constou da revisão de prontuários e exames tomográficos, em que foram mensurados o volume orbital pela segmentação de imagens no programa InVesalius e modelagem 3D no programa Magics, e a magnitude dos avanços craniofaciais, e seus vetores, foram medidos no programa Rhinoceros. Os resultados foram submetidos à análise estatística: teste t- Student e ANOVA. No Grupo MB, houve aumento de 8,94 mm3 e 9,84 mm3 para a variação do volume orbital, nas órbitas direita e esquerda, respectivamente; no Grupo LF: 5,70 mm3 e 5,77 mm3, respectivamente, para esses parâmetros. A resultante do avanço médio, para a órbita direita e esquerda no Grupo LF foi 11,36 ± 3,80 mm e 11,11 ± 3,45 mm, respectivamente; já no Grupo MB, foi 14,22 ± 4,12 mm e 14,48 ± 4,49 mm, respectivamente. A correlação entre a resultante do avanço e a variação dos volumes orbitais foi significante no Grupo LF e para a órbita esquerda no Grupo MB. Em conclusão, o procedimento cirúrgico foi eficaz, tanto para o Grupo LF como para o Grupo MB, pois, houve aumento estatisticamente significativo do volume orbital no período pós-operatório; não houve diferença estatisticamente significativa, na avaliação da simetria, entre os volumes orbitais pós-operatórios, direito e esquerdo. Ainda, não houve diferença estatisticamente significante entre os volumes orbitais pósoperatórios quando comparados aos índices de normalidade / Syndromic craniofacial synostosis (CS) is a congenital disorder, which is most often, an autosomal dominant mutation associated to FGFR1, FGFR2 and FGFR3 genes. It causes a premature fusion of craniofacial sutures, leading to deficiency in skull growth and middle-third of the face. The severity of the intracranial hypertension related, respiratory syndrome (hypopneaapnea) and eye (shallow orbits, ocular proptosis, exorbitism and lack of protection of the eyeball) symptoms, are parameters that indicate the surgical procedure. Distraction osteogenesis of the middle-third of the face is currently the chosen technique for the treatment of patients with Craniofacial Synostosis syndrome candidates for the advancement of the middle-third of the face. The 3D-tomography is a current option and seldom used for this purpose; this method allows better definition of anatomical structures without image distortion, providing a more accurate assessment of the results. The objectives of the present study, were to assess quantitatively the craniofacial advancement and its vectors through 3D tomographic images, the osteotomy Le Fort III and Monobloc with use of distractor devices; Also, to evaluate the correlation between the craniofacial advances and the variation of orbital volumes and determine the effectiveness of craniofacial advances through the comparison with normal levels of orbital volumes. From January 2001 to December 2012, 20 patients underwent distraction osteogenesis of the middle-third of the face, divided into two groups. LF group (n = 9) underwent a Le Fort III osteotomy and MB group (n = 11) underwent a monobloc frontalfacial osteotomy. The evaluation consisted of the reviewing of the records and tomographic exams; measured is the orbital volume by image segmentation on the InVesalius software and 3D modeling on Magics software and the magnitude of facial advances, and their vectors, were measured on Rhinoceros software. The results were subject to statistical analysis: t-Student test and ANOVA. In the MB group, there was an increase of 8.94 mm3 and 9.84 mm3 for the variation of the orbital volume, the right and left orbits, respectively; in Group LF: 5.70 mm3 and 5.77 mm3 for these parameters. The resulting of average advance, for right and left orbit in Group LF was of 11.36 ± 3.80 mm, 11.11 ± 3.45mm, respectively; as for group MB it was 14.22 ± 4.12 mm and 14.48 ± 4.49 mm, respectively. Correlation between the results from the progress and the variation of orbital volume was significant in Group LF and left orbit in MB Group. In conclusion, the surgical procedure was effective for both the LF group as for the MB Group because: there was a statistically significant increase in orbital volume on the postoperative period; there was no statistically significant difference in the evaluation of symmetry between the postoperative period left and right orbital volumes. Still, there was no statistically significant difference between the postoperative orbital volumes when compared to normal ranges
167

Estudo clínico prospectivo das modificações da borda alveolar inferior após projeção ortodôntica em tomografia computadorizada de feixe cônico / Prospective clinical study of the lower alveolar ridge modifications after orthodontic projection with cone beam computerized tomography

Flavio Cesar de Carvalho 27 February 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A projeção de incisivos e expansão dos arcos dentários são uma alternativa valiosa à extração dentária, especialmente quando se considera a estética facial em pacientes adultos. O efeito da projeção ortodôntica dos incisivos inferiores sobre o periodonto é controverso devido às avaliações em exames bidimensionais e os aspectos multi-fatoriais que envolvem as recessões gengivais. O objetivo deste estudo foi comparar as modificações na altura da borda alveolar dos dentes ântero-inferiores de pacientes, que foram submetidos à projeção ortodôntica, com pacientes tratados sem projeção; e correlacionar estas modificações com o grau de inclinação dentária, com as alterações da distância bicanina e com o biotipo gengival. Pacientes adultos com mais de 3 mm de falta de espaço no arco inferior e curva de Spee moderada ou acentuada compuseram o grupo experimental (n=15). O grupo controle (n=7) consistiu de pacientes com bons arcos inferiores, que não necessitavam de grandes movimentos dentários. Estes pacientes foram submetidos a alinhamento e nivelamento dentário até o fio de aço .020". Tomografias computadorizadas de feixe cônico (TCFC) foram obtidas antes do tratamento e ao final da fase de alinhamento e nivelamento. As alturas das bordas alveolares (BA) de incisivos e caninos inferiores foram medidas nas TCFC em reconstruções 3D e comparadas entre os grupos e entre os tempos pelos testes-t de Student não pareado e pareado, respectivamente. As BA foram correlacionadas com o grau de inclinação dentária (IMPA), com a distância intercaninos (DIC) e com o biotipo gengival (BG) pelo teste de correlação de Pearson. Os resultados demonstraram que os caninos inferiores do grupo experimental apresentaram perda óssea significativa (p<0,005), quando comparados com o grupo controle, em média 2,5 mm. As BA dos dentes 43, 33 e 32 ao final do alinhamento e nivelamento eram significativamente maiores do que ao início do tratamento no grupo experimental (p<0,001). Não foram encontradas diferenças significativas entre as medidas iniciais e finais das BA de todos os dentes do grupo controle. Apesar destes resultados, não foram encontradas correlações entre a remodelação da BA e o IMPA, a DIC e o BG. Pode-se concluir que o aumento no comprimento do arco inferior com arcos ortodônticos contínuos aumenta a inclinação dos incisivos inferiores e a DIC. O aumento da DIC parece exercer maior efeito sobre a BA dos caninos inferiores do que a inclinação de incisivos sobre a BA dos incisivos inferiores. No entanto, as modificações da BA não estão associadas ao grau de inclinação dos incisivos, a quantidade de expansão do arco inferior e ao biotipo gengival. / Incisor proclination and dental arch expansion are a valuable choice of treatment instead of extraction, especially when considering facial aesthetics in adult patients. The effect of orthodontic projection of the lower incisors on the periodontium is controversial because of evaluation in two-dimensional exams and the multi factorial aspects of gingival recessions. The aim of this study was to compare alveolar height modifications in the lower arch of patients that were treated with orthodontic proclination, with patients treated without proclination, and correlate these modifications with the degree of dental projection, with the changes in the lower intercanine width and with gingival biotype. Adult patients with lower arch discrepancy of more than 3 mm and moderate or pronounced curve of Spee composed the experimental group (n=15). The control group (n=7) consisted of patients with good lower arches, that did not need large dental movements. These patients had their dental arches aligned and leveled up to a .020 wire. Cone beam computed tomography (CBCT) was taken before treatment and after leveling and alignment. The height of the alveolar border (AB) of the lower incisors and canines were measured on CBCT with 3D reconstruction, and compared between groups, and between times, by paired and independent Students t-test, respectively. The AB were correlated with the degree of dental inclination (IMPA), intercanine width (ICW) and gingival biotype (GB) by the Pearson correlation test. Results showed that the lower canines of the experimental group presented significant bone loss (p<0,005) when compared with the control group, with a mean of 2.5 mm. The AB of teeth 43, 33 and 32 at the end of alignment were significantly greater than at beginning of treatment for the experimental group (p<0,001). No significant differences were found between initial and final AB measurements for all control group teeth. Despite these results, no correlation was found between remodeling of AB and IMPA, ICW and GB. It can be concluded that the increase of lower arch length with continuous orthodontic archwires increases lower incisor inclination and ICW. The increase of the ICW seems to exert more effect over the AB of lower canines, than the incisor inclination over the AB of the incisors. However, AB modifications are not associated with the degree of incisors inclination, neither the amount of lower arch expansion, nor to the gingival biotype.
168

Método de desenvolvimento de órtese personalizada de baixo custo para a manufatura aditiva / Method for low-cost custom orthosis development aiming additive manufacturing

Weigert, Mateus Collares 31 July 2017 (has links)
CAPES; CNPq / O emprego da Manufatura Aditiva (AM) vem aperfeiçoando a confecção de produtos assistivos customizados, mas para a sua utilização se faz necessário gerar o modelo geométrico digital. Uma das alternativas para obtê-lo é com o uso de escâneres 3D. Após a digitalização, dificilmente o resultado alcançado, geralmente uma malha digital da superfície 3D do modelo físico, pode ser utilizado diretamente na AM. Para tanto, é exigido alguns tratamentos desta tmalha em programas CAD (Computer-Aided Design) 3D. Algumas dessas ferramentas, tanto os escâneres 3D quanto os programas CAD 3D, são viáveis, mas de alto custo. Além disso, a etapa de tratamento da malha não é abordada nos estudos encontrados, prejudicando a disseminação dessas tecnologias. Desta forma, o presente trabalho propõe um método de baixo custo para o desenvolvimento de órtese de membro superior visando a fabricação por AM, tendo como foco principal a abordagem das etapas de tratamento da malha e modelagem da órtese. Como objeto de estudo foram utilizados 12 moldes em gesso de punho, mão e dedos confeccionados por um terapeuta ocupacional. A digitalização dos moldes em gesso ocorreu com o emprego de dois sistemas de baixo custo, o sensor do Kinect 360 e o programa Remake, e um de alto custo para servir como referência, o escâner REVscan. Para as etapas de tratamento da malha e modelagem da órtese foram utilizados dois programas CAD 3D gratuitos: Blender e Meshmixer. Os digitalizadores de baixo custo geraram malhas que foram validadas ao compará-las as geradas pelo REVscan. Diferentemente do Remake, o Kinect gerou malhas sem defeitos e em menor tempo, porém, apresentou os maiores desvios dimensionais e os maiores tamanhos de arquivo. Os defeitos apresentados nas malhas geradas pelo Remake foram do tipo lacunas e foram corrigidos com êxito pelos programas CAD 3D. Na etapa de tratamento da malha foi constatada a relevância da etapa de suavização das bordas no resultado final da órtese. Os resultados ressaltaram a importância da etapa de tratamento e correção das malhas para o desenvolvimento de produtos assistivos visando a fabricação por AM. De forma geral, foi possível desenvolver órteses personalizadas utilizando as ferramentas de baixo custo. Os procedimentos descritos neste estudo podem auxiliar no desenvolvimento de produtos assistivos e propiciar a disseminação desse conhecimento nas empresas e instituições dispensadoras de órteses. / The use of the Additive Manufacturing (AM) has improved the production of customized assistive products, but its use needs to generate the digital geometric model first. One of the alternatives to get it is with the use of 3D scanners. After the scanning, hardly the result achieved, usually a digital STL (stereolithography format) mesh of the 3D surface of the physical model, can be used directly in AM. Therefore, it is required some mesh treatments in 3D CAD (Computer-Aided Design) programs. Some of these tools, both 3D scanners and 3D CAD programs, are feasible but high cost. In addition, the mesh treatment step is not addressed in the studies found, hampering the spread of these technologies. In this way, the present work proposes a low cost method for the development of upper limb orthosis aimed at manufacturing by AM, focusing mainly on the steps of mesh treatment and orthosis modeling. As object of study were used 12 gypsum molds of wrist, hand and fingers made by an occupational therapist. The 3D digitizing of plaster casts occurred using two low-cost systems, the Kinect 360 sensor and the Remake program, and a high-cost scanner to serve as a reference, the REVscan. For the steps of mesh treatment and orthoses modeling, two free 3D CAD programs were used: Blender and Meshmixer. The lowcost scanners generated meshes that were validated by comparing them to those generated by REVscan. Unlike Remake, Kinect generated non-defective meshes and in less time, however, presented the largest dimensional deviations and the largest file sizes. The defects presented in the meshes generated by Remake were of the gaps type and were corrected successfully by 3D CAD programs. In the mesh treatment step, it was verified the relevance of the procedure of smoothing the edges in the final orthosis result. The results highlighted the importance of the meshes treating step for the development of assistive products aiming the manufacture by AM. In general, it was possible to develop customized orthoses using low-cost tools. The procedures described in this study can assist in the development of assistive products and facilitate the dissemination of this knowledge in companies and institutions that provide orthosis.
169

Um método computacional livre de modelo esquelético para rastreamento e reconstrução em tempo real de múltiplos marcadores em sistemas de captura de movimento ópticos

Furtado, Daniel Antônio 07 March 2013 (has links)
Universidade de Uberaba / In the past years, motion capture has been widely used in many application areas. In movies and games, motion capture is frequently employed to animate virtual characters. In sports, motion capture and analyses focus on optimizing movements of athletes and injury prevention. More applications areas include medicine, military and engineering. Motion capture can be accomplished by several technologies. However, optical marker-based systems are considered the gold standard of the motion capture field. They can offer high precision levels and flexibility to support most applications, but they are also the most expensive systems due to high costs of hardware and software. Although low-cost optical systems have been proposed in the last decade, these systems cannot provide enough precision, flexibility, automatism and/or real-time capability for a number of applications. In this context, the present research aims to develop a complete and high precision approach to track and reconstruct a cloud of independent markers, in real time, using multiple infrared specialized cameras. The proposed method includes a set of relatively simple algorithms which are part of a three-stage procedure. These stages work on the tracking and matching of the image points and spatial reconstruction of the marker trajectories. In order to evaluate the method, a prototype software has been implemented and experiments were performed using a pack of eight infrared cameras. The NaturalPoint s OptiTrack system, which includes the Arena software, was used as a reference system. In the experiments, the proposed technique was able to successfully track and reconstruct a set of 38 reflective markers in real time. When compared to the commercial software, the method performed better for automatically maker tracking. In addition, the reconstructed trajectories produced by the prototype software were far less contaminated by noise than the trajectories generated by the Arena software. The proposed method should encourage the development of new high performance systems at a more affordable price. / Nos últimos anos, os sistemas de captura de movimento vêm sendo aplicados em diversas áreas do conhecimento. A animação de personagens virtuais na indústria cinematográfica e a avaliação dos movimentos corporais em áreas da saúde e nos esportes são apenas algumas de suas diversas aplicações. Dos diferentes tipos de sistemas de captura de movimento existentes, os sistemas ópticos baseados em marcadores são reconhecidos como os mais avançados e os que oferecem níveis de precisão e flexibilidade suficientes para suportar o maior número de aplicações. Todavia, esses sistemas estão também entre os mais caros, devido ao alto preço dos elementos de hardware e software. As propostas de baixo custo existentes possuem limitações com relação à precisão, flexibilidade, automatismo e/ou velocidade de processamento, que as tornam inviáveis para uma considerável parcela de aplicações. Neste contexto, esta pesquisa propõe um método computacional completo, considerando as principais deficiências dos trabalhos existentes, para rastrear e reconstruir as trajetórias de uma nuvem de marcadores reflexivos independentes, em tempo real, utilizando múltiplas câmeras especializadas de infravermelho. A técnica proposta envolve um conjunto de algoritmos relativamente simples, os quais integram três etapas principais. Estas etapas realizam o rastreamento e o casamento dos pontos nas imagens e a reconstrução tridimensional das trajetórias dos marcadores. O método foi implementado em software e testado utilizando uma coleção de oito câmeras de infravermelho. Como referência, utilizou-se o software Arena e o sistema OptiTrack comercializado pela empresa NaturalPoint. Nos experimentos conduzidos, a técnica foi capaz de rastrear automaticamente um conjunto de 38 marcadores em tempo real. Comparada ao software comercial Arena, a técnica revelou uma melhor capacidade de rastreamento automático dos marcadores e ainda reconstruiu trajetórias com menor incidência de ruídos. O método proposto deve incentivar pesquisadores e empresas a desenvolverem sistemas de captura de movimento de alto desempenho e com menor custo. / Doutor em Ciências
170

Controle com lógica Fuzzy e Neurofuzzy aplicada à análise e programação de robôs móveis com visualização e simulação 3D / Fuzzy and Neurofuzzy controls applied to analise and programming mobile robots with 3D visualization and simulation

Felipe Sertã Abicalil 30 August 2007 (has links)
Este trabalho tem como objetivo o estudo de uma área da robótica chamada robótica móvel. Um robô móvel deve realizar uma navegação segura e esta é a principal motivação deste trabalho. Para tal foi desenvolvido um simulador de robótica móvel com visualização em 3D. Um dos grandes interesses na área de robótica móvel é a utilização de algoritmos de inteligência artificial. O objetivo deste trabalho é a utilização e simulação de inteligência artificial para o controle destinado ao desvio de obstáculos. As simulações são dinâmicas, ou seja, o robô não tem informação previa do cenário. Os algoritmos de inteligência artificial implementadas neste trabalho são lógica Fuzzy e Neurofuzzy. As contribuições do simulador são: a simulação e visualização em 3D com o cenário modelado em um programa CAD/3D, permite testar diversas configurações antes de testar o robô real, simula o ruído de sensores, utiliza lógica fuzzy e neurofuzzy para o desvio de obstáculos. Os resultados mostram a capacidade do sistema fuzzy para lidar com os dados ruidosos dos sensores assim como a influência das variáveis antecedentes e conseqüentes do sistema fuzzy de no comportamento do robô móvel para o desvio de obstáculos além da capacidade do sistema neurofuzzy de aprender a partir dos dados de treinamento mostrando uma melhoria no resultado das simulações. / This work has as objective the study of an area of the robotics named mobile robotics. A mobile robot must navigate in a safe way and this is the main motivation of this work. To do that a mobile robotics simulator with 3D visualization was developed. One of the great interests in mobile robotics is using artificial intelligence algorithms. The main point of this work is using and simulate artificial intelligence applied in obstacle avoidance control. The simulations are dynamics it means that the robot do not have previous information about the scenery. The artificial intelligence algorithms developed in this work are Fuzzy and Neurofuzzy logics. The simulator contributions are that the simulation and 3D visualization where the scenery is a 3D model from a CAD/3D software besides allows to test many configurations before testing the real robot and simulates noise from sensors and uses fuzzy and neurofuzzy logics to obstacle avoidance. The results show the fuzzy system capability to deal with the noisy data from sensors and how fuzzy variables influences the mobile robot behavior in obstacle avoidance besides the ability of neurofuzzy system to learn from training data showing improvements in the simulation results.

Page generated in 0.0903 seconds