Spelling suggestions: "subject:"implantes dentários"" "subject:"aimplantes dentários""
321 |
Efeito da inclinação e do número de implantes em próteses totais fixas implantossuportadas: análise de elemento finito não linear com modelo tridimensionalGeremia, Tomás January 2014 (has links)
Made available in DSpace on 2015-04-30T14:06:27Z (GMT). No. of bitstreams: 1
000467680-Texto+Completo-0.pdf: 13016515 bytes, checksum: e3ef505603c7d5be9a1581e535fd60e2 (MD5)
Previous issue date: 2014 / The aim of this study was to evaluate the influence of the number of implants and the distal tilting of posterior implants (27 degrees) on the resulting tensions in periimplant bone, abutment screw and prosthetic screw of mandibular full-arch fixed implant supported prosthesis, using a nonlinear finite element analysis. Six virtual models were created, simulating a mandibular full-arch prosthesis with a metallic framework: models with five parallel implants (5R) and with tilted posterior implants (5I); models with four parallel implants (4R) and tilted posterior ones (4I); and models with three parallel implants (3R) and with tilted posterior implants (3I). The Von Mises tensions were analyzed, on a qualitative aspect, on the three regions of interest. The results showed that tilting the posterior implants resulted in higher tensions on the periimplant bone region. Also, the implant placed adjacent to the loading area presented the higher stress magnitudes on the three regions of interest, during all the simulations. Within the limitations of this study, it's possible to conclude that tilting the posterior implants without distalizing the implants platforms, can represent higher Von Mises tensions on the cortical periimplant bone. Still, that the use of three implants supporting a mandibular full-arch prosthesis generated higher stress values on the analyzed regions, when compared to the models simulating four and five implants. / O objetivo do presente trabalho foi avaliar em reabilitações totais fixas implantossuportadas, através de uma Metodologia de Elementos Finitos não linear, a influência do número e da inclinação dos implantes posteriores em 27 graus para distal nas tensões em osso periimplantar cortical, parafuso do pilar protético e parafuso protético. Seis modelos virtuais foram gerados simulando uma prótese total fixa mandibular, com infraestrutura metálica: modelos com 5 implantes, paralelos entre si (5R) e com dois posteriores inclinados (5I); modelos com 4 implantes, paralelos entre si (4R) e com dois posteriores inclinados (4I); modelos com 3 implantes, paralelos entre si (3R) e com dois posteriores inclinados (3I). Uma força de 100 N foi simulada em região de primeiro molar, no cantilever protético. As tensões Von Mises resultantes foram analisadas de forma qualitativa nas três regiões de interesse. Os resultados mostraram que a utilização de implantes posteriores inclinados resultaram em maiores tensões na região periimplantar. Ainda, que o implante adjacente à carga apresentou os maiores valores de tensão nas três regiões avaliadas em todas as simulações. Dentro das limitações deste trabalho, pode-se concluir que a inclinação de implantes posteriores, sem a distalização das plataformas dos mesmos, mostra-se desfavorável no que diz respeito à incidência de tensões no osso periimplantar cortical. Além disso, a utilização de três implantes suportando uma prótese total fixa mandibular, apresentou maiores valores de tensão se comparado as situações com quatro e cinco implantes.
|
322 |
Avaliação histológica do contato osso-implante e estabilidade de implantes com superfícies modificadas: estudo experimental em tíbias de coelhos / Effect Of Implant Surface Properties On Osseointegration, Bone-To-Implant Contact And Stability Of Modified Sand-Blasted Acid-Etched Implants: An Experimental Study In RabbitsNunes, Leandro Soeiro de Souza January 2014 (has links)
Made available in DSpace on 2015-05-22T12:38:48Z (GMT). No. of bitstreams: 1
000468625-Texto+Completo-0.pdf: 2863238 bytes, checksum: 3e057c78a6b6e5cfbd0cf6767d59dd26 (MD5)
Previous issue date: 2014 / The clinical success of the implant treatment is strongly related with the achievement and maintenance of the stability of the fixture. As the surface topography, roughness and wettability are modifications that can affect the quality of the osseointegration, several studies have analyzed the benefits of these modifications. The histomorphometric analyses of the bone-to-implant contact (BIC) and the resonance frequency analyses (RFA) are commonly used to verify the osseointegration and implant stability.In the present study, 32 implants with two different surfaces treatment were installed in the tibia of 16 New Zealand rabbits and splitted in two groups. The Group I was formed by Neodent Drive implants, with sandblasted, acid etched and hydrophilic surface (Neodent Drive Acqua, Neodent, Curitiba, Brasil). The Group II was formed by Neodent Drive implants, with sandblasted and acid etched surface (Neodent Drive Porous, Neodent, Curitiba, Brasil). The samples were analyzed at 07, 14, 30 and 60 days after the implant placement.The results showed statistically significant differences between the mean values for the BIC at 14 (p=0. 028) and 30 days (p=0. 028). The mean BIC for the Acqua implants (Group I) were 43,32 ± 1,31% and 55,03 ± 5,14%, at 14 and 30 days respectively. The mean BIC in the Porous implants (Group II) were 46,27 ± 0,10% and 47,13 ± 0,67%, at 14 and 30 days, respectively. At 60 days, the mean BIC for the Acqua implants were 54,68 ± 3,51% and for the Porous implants were 50,86 ± 1,03%.There were not statistically significant differences in the implant stability quotient (ISQ) measurements between Acqua and Porous implants, except at 07 days after the implant placement. At day 07, the results of the present study showed higher ISQ values for the Porous implants (68,75 ± 4,16%) than Acqua implants (61,5 ± 8,01%). The follow-up ISQ analyses in the same Group, showed statistically significant increases of the mean values from 7 to 60 days and from 30 to 60 days, for both groups.In conclusion, the sandblasted and acid etched treatment used to create roughness on the Neodent implant surface is reliable and allows bone apposition, as the BIC and ISQ values found were similar or superior than the showed in the literature for similar animal models and similar implant surface. The increase of the BIC and ISQ values on the follow up showed the achievement of the secondary stability and the increase in stiffness between the implant fixture and the surrounding tissues. There were not identified better results with the hydrophilic surface during the early period of healing. Thus, further investigations are necessary to confirm the suggested results in this present study. / A obtenção e a manutenção da estabilidade do implante são pré-requisitos para o sucesso clínico das próteses sobre implantes. Visto que a topografia, a rugosidade e a hidrofilicidade são algumas das alterações da superfície dos implante que podem alterar a resposta do tecido ósseo, diversos estudos tem procurado entender os benefícios que estas modificações podem proporcionar. A quantificação histomorfométrica do contato osso-implante (BIC) e a análise de frequência de ressonância (AFR) são parâmetros frequentemente utilizados na implantodontia para verificar a osseointegração e a estabilidade dos implantes.No presente estudo, foram instalados 32 implantes com duas diferentes superfícies nas tíbias de 16 coelhos, divididos em dois grupos: Grupo I) constituído pelos implantes com superfície tratada por jateamento de areia, ataque ácido, hidrofílica e modificada quimicamente (Neodent Drive Acqua, Neodent, Curitiba, Brasil) e Grupo II) constituído pelos implantes com superfície tratada por jateamento de areia e ataque ácido (Neodent Drive Porous, Neodent, Curitiba, Brasil). As amostras foram analisadas após 7, 14, 30 e 60 dias da colocação dos implantes.Na comparação da média geral do BIC, entre Acqua e Porous, foram observadas diferenças estatisticamente significantes no período de 14 dias (p=0,028) e no período de 30 dias (p=0,028). As medidas médias de BIC obtidas para os implantes Acqua foram 43,32 ± 1,31% e 55,03 ± 5,14%, aos 14 e 30 dias respectivamente. Para os implantes Porous, as medidas de BIC foram 46,27 ± 0,10% e 47,13 ± 0,67%, aos 14 e 30 dias respectivamente. No período de 60 dias, os valores médios de BIC da superfície Acqua foram 54,68 ± 3,51% e da superfície Porous foram 50,86 ± 1,03%.Na comparação da média geral do quociente de estabilidade do implante (QEI), entre Acqua e Porous, não foram observadas diferenças estatisticamente significantes entre os grupos, com exceção no período de 07 dias, no qual os resultados do presente estudo demonstraram maiores valores de QEI para o grupo Porous (68,75 ± 4,16%) do que para o grupo Acqua (61,5 ± 8,01%). A análise do QEI durante os diferentes períodos dentro de um mesmo grupo, demonstrou diferenças estatisticamente significativas entre os períodos de 7 vs 60 dias e 30 vs 60 dias, para a média geral do QEI no grupo Acqua e no grupo dos implantes Porous.As conclusões do presente estudo são que os resultados demonstraram que a modificação da superfície por jateamento de areia e ataque ácido utilizada para produzir as superfícies Acqua e Porous resulta em uma adequada aposição óssea, visto que os valores do BIC e QEI encontrados são similares ou superiores aos resultados encontrados na literatura com modelos experimentais e superfícies similares. Os aumentos dos valores do BIC e QEI durante os períodos pós-operatórios revelaram a obtenção de estabilidade secundária e maior rigidez na ancoragem do implante com o passar do tempo. Não foram identificados melhores resultados com a superfície hidrofílica nos períodos iniciais da osseointegração. Sendo assim, são necessários estudos pré-clínicos e clínicos para confirmar as sugestões que os resultados deste presente estudo revelaram.
|
323 |
Protocolo de preservação óssea para avaliação de tecido ósseo e osseointegração de implantes de titânioKunrath, Marcel Ferreira January 2016 (has links)
Made available in DSpace on 2016-04-08T03:06:45Z (GMT). No. of bitstreams: 1
000477915-Texto+Completo-0.pdf: 595 bytes, checksum: dc72b670df365af7e40c72ed34834b2e (MD5)
Previous issue date: 2016 / With the growing expansion of implant surfaces and the need for greater speed of osseointegration, methods of analysis of bone tissue and implant surface as well as the quality of the bone implant contact (BIC), they are increasingly being explored by researchers. The aim of this study is to show detail and describe a bone preservation protocol for making implants samples with and without implants without any harm or damage, or the bone tissue or the properties of the metal, preserving the BIC. In a second step, the samples prepared by the protocol preservation were compared with those made by histological analysis method for staining for HE, considered the gold standard for living tissue. Eight samples were used for bone tissue with implants in rabbit tibia and more four fragments of jaws without implants of the same rabbits. Samples with and without implants were made by the two protocols, after preparation of the test specimens, analysis by optical microscopy of transmission and reflection through scanned images were made. Each protocol had advantages when the results were analyzed individually in the implants without samples, becoming further analysis. However, for samples with implants, analysis only by histological method cannot bring good results, while the bone preservation method showed excellent results for osseointegration analysis, bone formation and bone implant interface. It follows that the bone preservation protocol is an excellent method for analyzing samples with implants, and can be complementary to histology, in analysis bone samples without implants. The histological method is not sufficient for analysis of bone formation and bone implant interface. / Com a crescente expansão de superfícies de implantes e a necessidade de maior velocidade de osseointegração, métodos de análise do tecido ósseo, análises da superfície de implantes e a qualidade do contato osso-implante (BIC) estão cada vez mais sendo explorados pelos pesquisadores. O objetivo do presente estudo foi descrever detalhadamente um protocolo de preservação óssea para confecção de amostras com e sem implantes, sem causar danos ou avarias nem ao tecido ósseo nem às propriedades do metal, preservando o BIC. Em uma segunda etapa, as amostras confeccionadas pelo protocolo de preservação óssea foram comparadas com as amostras preparadas pelo método de análise histológica por coloração por Hematoxilina-Eosina, considerado padrão ouro para tecidos vivos. Foram utilizadas oito amostras de tecido ósseo com implantes de tíbias de coelhos e, mais quatro fragmentos de mandíbulas sem implantes, dos mesmos coelhos. As amostras com e sem implantes foram confeccionadas pelos dois protocolos e, após a preparação dos corpos de prova, foram feitas as análises por microscopia óptica de transmissão e reflexão através de imagens digitalizadas. Cada protocolo apresentou vantagens quando os resultados foram analisados individualmente nas amostras sem implantes. Porém, para as amostras com implantes, a análise apenas pelo método histológico não conseguiu apresentar bons resultados, enquanto que o método de preservação óssea mostrou excelentes resultados para análise de osseointegração, neoformação óssea e interface osso-implante. Conclui-se que o protocolo de preservação óssea desenvolvido mostrou-se um excelente método para análise de amostras com implantes, e que pode ser complementar à histologia, em análises de tecido ósseo sem implantes. O método histológico não mostrou-se suficiente para análise de neoformação óssea e interface osso-implante.
|
324 |
Tratamento biomimético de discos e implantes de titânio com alendronato. Caracterização topográfica, estudo histométrico e imunoistoquímico em coelhos / Biomimetic treatment of titanium disks and implants with alendronate. Topographic characterization, histometric and immunohistochemical study in rabbitsFigueira Júnior, Heldo Cesar [UNESP] 02 March 2018 (has links)
Submitted by HELDO CESAR FIGUEIRA JÚNIOR (heldo_jr@hotmail.com) on 2018-04-19T20:19:14Z
No. of bitstreams: 1
Tese Heldo 1.pdf: 3359547 bytes, checksum: 9196a74235c978887c23c253d46d4876 (MD5) / Approved for entry into archive by Ana Paula Rimoli de Oliveira null (anapaula@foa.unesp.br) on 2018-04-19T20:44:13Z (GMT) No. of bitstreams: 1
figueirajunior_hc_dr_araca_int.pdf: 3315964 bytes, checksum: 465aa0e1b0370a0d91f21608bedfa112 (MD5) / Made available in DSpace on 2018-04-19T20:44:13Z (GMT). No. of bitstreams: 1
figueirajunior_hc_dr_araca_int.pdf: 3315964 bytes, checksum: 465aa0e1b0370a0d91f21608bedfa112 (MD5)
Previous issue date: 2018-03-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Tratamentos de superfície de materiais implantáveis no corpo humano são analisados incansavelmente dentro das áreas da saúde. É comum ser observado em artigos científicos o emprego de um recente e desconhecido biomaterial sendo analisado para este fim. O objetivo deste estudo foi avaliar o emprego do alendronato sobre a caracterização topográfica de implantes e discos de titânio in vitro, e sobre a superfície de implantes de titânio inseridos em coelhos após levantamento de seio maxilar, correlacionando as respostas biológicas e físicas do tratamento comparadas a protocolos bem estabelecidos da implantodontia. Utilizou-se seis discos e vinte e seis implantes dentários ambos de titânio comercialmente puro. Para as análises topográficas, discos e implantes se dividiram em 2 grupos de 3 amostras: Grupo CTL, submetidos a subtração ácida e grupo ALD, submetidos a tratamento biomimético com alendronato. Para os testes em animais, 5 implantes foram distribuídos por grupo, CTL e ALD, com intervalos de eutanásia de 7 e 40 dias. Após microscopia eletrônica de varredura, análise de espectroscopia por energia dispersiva, análise do ângulo de contato com a água, de energia livre de superfície e da presença de sítios doares de elétrons (base de Lewis), os grupos ALD apresentaram resposta satisfatória frente aos processos aceitos em saúde, sendo superiores em todas as análises. A resposta histométrica também foi mensurada resultando em maior tecido ósseo nas análises ELCOI e AON nos grupos ALD 40 dias. A discreta presença do TRAP aos 40 dias se refere a baixa reabsorção óssea no momento testado, fator relacionado ao uso de um bisfosfonato à nível local. A osteocalcina em 7 dias sugere uma atividade celular propícia à neoformação. Os tratamentos de biomiméticos são válidos uma vez que, frente aos testes realizados, melhoram a interação dos implantes a nível celular. O alendronato pode ser empregado para os fins propostos resultando em melhora do processo de reparo ósseo. / Surface treatments of implantable materials in the human body are analyzed tirelessly within the health areas. It is common to observe in scientific articles the use of a recent and unknown biomaterial being analyzed for this purpose. The objective of this study was to evaluate the use of alendronate on the t opographic c haracterization of implants and titanium discs in vitro , and over the surface of titanium implants inserted into rabbits after maxillary sinus lift, correlating the biological and physical responses of the treatment compared to well established implantology protocols. It was used six disks and twenty - six commercially pure titanium dental implants. For the topographic analyzes, disks and implants were divided into 2 groups of 3 samples: CTL group, submitted to acid subtraction and ALD group, submi tted to biomimetic treatment with alendronate. For the animal tests, 5 implants were distributed per group, CTL and ALD, with euthanasia intervals of 7 and 40 days. After scanning electron microscopy, analysis of energy dispersive spectroscopy, analysis of the water contact angle, free surface energy and the presence of electron ́s donor sites (Lewis base), the ALD groups showed a satisfactory response to the accepted processes in health, being superior in all the analyzes. The histometric response was also measured resulting in increased bone tissue in the ELCOI and AON analyzes in the ALD 40 days’ group. The discrete presence of TRAP at 40 days refers to low bone resorption at the time tested, a factor related to the use o f a bisphosphonate . Osteocalcin in 7 days suggests a cellular activity conducive to neoformation. Biomimetic treatments are valid since, given the tests performed, they improve the interaction at the cellular level. Alendronate can be used for the proposed applications resulting in a better bone repair process.
|
325 |
Influência do torque e da ciclagem mecânica na manutenção da pré-carga e resistência à fratura de parafusos de retenção em diferentes junções parafusadas /Silva, Ebele Adaobi. January 2016 (has links)
Orientador: Wirley Gonçalves Assunção / Coorientadora: Maria Cristina Rosifini Alves Resende / Banca: Stefan Fiuza de Carvalho Dekon / Banca: Juliana Aparecida Delben / Resumo: Sendo o afrouxamento e fratura dos parafusos de retenção as principais complicações em próteses implantossuportadas, este estudo teve como objetivo avaliar a manutenção do torque remanescente e ocorrência de fraturas em parafusos de retenção de pilares UCLA, para implantes de conexão hexagonal externa e cone Morse, em função do torque aplicado (recomendado pelo fabricante, torque obtido através de aperto manual e sem torque), submetidos à ciclagem mecânica. Sequencialmente, investigou-se a resistência à fratura desses parafusos por meio do teste de compressão em uma máquina de ensaio universal. Foram utilizados 36 implantes embutidos em poliuretano com uma inclinação de 30°, divididos em 6 grupos em função do tipo de conexão e do torque aplicado. De forma randomizada, os espécimes pertencentes ao grupo sem torque foram submetidos a ciclagem mecânica e os dos grupos torque recomendado pelo fabricante e torque manual foram submetidos a aplicação do torque e mensuração da pré-carga remanescente, antes (3 minutos após o aperto) e após a ciclagem mecânica (após 1x106 de ciclos). Ao fim da ciclagem, os parafusos foram submetidos ao teste de resistência a fratura por meio do ensaio de compressão, no qual foi aplicado uma carga de 5000N sob a velocidade de 0,5mm/min. Os resultados mostraram que em uma análise geral, o torque remanesce foi significantemente menor (p<0,05) após a ciclagem mecânica. Ao se comparar os dois tipos de conexão, não houve diferença em relação o torque remanes ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Being loosening and fracture of retention screws the main complications in implant-supported prostheses, this study aimed to evaluate the preload maintenance and the occurrence of fractures at retention screws of UCLA-type abutment for implants with external hexagon connection and Morse Taper, due to the applied torque (recommended by the manufacturer, torque obtained by manual tightening and no torque), submitted to mechanical cycling. Sequentially, the fracture resistance of these screws was investigated by the compression test on a universal testing machine. Thirty-six implants embedded in polyurethane with an inclination of 30° were used and divided into 6 groups according to the type of connection and the applied torque. Randomly, the specimens belonging to the group without torque underwent mechanical cycling and groups of recommended by the manufacturer torque and manual torque underwent torque application and measurement of the remaining preload, before (three minutes after tightening) and after mechanical cycling (after 1x106 cycles). After cycling, the screws were submitted to the fracture resistance test by the compression test, which was applied a 5000N load under 0,5 mm/min speed. The results showed that in a general analysis, preload maintenance was significantly lower (p <0,05) after mechanical cycling. When comparing the two types of connection, there was no difference regarding to preload maintenance (p>0,05). For different types of torque, it was observed ... (Complete abstract click electronic access below) / Mestre
|
326 |
Avaliação da prevalência das doenças peri-implantares e do sucesso e sobrevivência de implantes osseointegrados com 8 a 10 anos de função /Marcantonio, Claudio. January 2014 (has links)
Orientador: Daniela Leal Zandim Barcelos / Co-orientador: / Banca: José Eduardo Cezar Sampaio / Banca: Francisco de Assis Molo Junior / Banca: Rafael Silveira Faeda / Banca: Waldyr Antonio Jorge / Resumo: O propósito deste estudo retrospectivo foi verificar as taxas de sucesso e sobrevivência de implantes osseointegrados no longo prazo, assim como determinar a prevalência de doenças peri-implantares e identificar possíveis fatores de risco associados à ocorrência da peri-implantite. A amostra foi constituída de 50 pacientes parcialmente desdentados que realizaram reabilitações sobre implantes osseointegrados no período de 2003 a 2005. As avaliações incluíram a coleta de informações demográficas, sistêmicas e comportamentais, além de exames clínicos e radiográficos para avaliação da condição periodontal e peri-implantar. Uma análise multivariada foi adotada para identificar possíveis preditores de risco para a periimplantite. Um total de 211 implantes foram instalados nestes pacientes. Cinco implantes foram perdidos e 9 implantes encontravam-se submersos, ou seja, sem função. Assim, 197 implantes em 48 pacientes foram avaliados clinicamente. A prevalência de mucosite foi de 77,1% a nível de paciente e 52,3% a nível de implante. A peri-implantite foi diagnosticada em 25 implantes em 14 pacientes. As taxas de sucesso e de sobrevivência encontradas foram de 82% e de 97,6%, respectivamente. A presença de osteoporose (OR = 2,87) e a presença de sangramento à sondagem (SS) de boca toda ≥ 30% dos sítios (OR = 8,03) foram variáveis relacionadas ao indivíduo significativamente associadas com maior ocorrência de periimplantite. A presença de placa visível (OR = 4,45) e a presença de sítios com profundidade de sondagem (PS) ≥ 4 mm (OR = 4,47) foram variáveis relacionadas ao implante significativamente associadas com maior ocorrência de peri-implantite. Apesar da alta taxa de sobrevivência no longo prazo, foi observada uma alta prevalência de mucosite e a peri-implantite foi diagnosticada em 12,7% dos implantes e 29,2% dos pacientes avaliados...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract:The aim of the present study was to verify the long-term success and survival rates of osseointegrated dental implants, as well to determine the prevalence of peri-implant disease, and to identify potential risk factors associated to the occurrence of peri-implantitis. The sample was comprised of 50 patients who had their implant-supported rehabilitation concluded between the years of 2003 and 2005. Evaluations included the gathering of demographic, systemic and behavioral information, as well as radiographic and clinical records for the assessment of periodontal and peri-implant conditions. Multivariate analysis was employed to identify potential risk factors related to the occurrence of peri-implantitis. A total of 211 implants were installed, out of which 5 were lost and 9 were submerged, that is, nonfunctioning. Thus, 197 implants in 48 patients were clinically evaluated. The presence of osteoporosis (OR = 2,87) and the presence of full-mouth BOP scores ≥ 30% of sites (OR = 8,03) were variables significantly associated with a higher occurrence of peri-implantitis, among the subjects. At the implant level, the presence of visible plaque (OR = 4.45) and the presence of sites with probing depth (PD) ≥ 4 mm (OR = 4.47) were variables significantly associated with a higher occurrence of peri-implantitis. Mucositis prevalence was 77.1% and 52.3%, at subject and implant level, respectively. Periimplantitis was diagnosed in 25 implants (12.7%) and 14 patients (29.2%). Success and survival rates were 82% and 97.6%, respectively. Our results suggest that subjects with osteoporosis and with full-mouth BOP scores ≥ 30% of the sites, as well as implants with visible plaque and sites with PD ≥ 4 mm, are more susceptible to peri-implantitis. / Doutor
|
327 |
Carbono tipo diamante em componentes de implantes dentários: avaliação das propriedades antimicrobianas e de adesão de Escherichia coli /Maquera Huacho, Patricia Milagros. January 2014 (has links)
Orientador: Denise Madalena Palomari Spolidorio / Banca: Luis Geraldo Vaz / Banca: Rafael Silveira Faeda / Resumo: O estudo de filmes de Carbono tipo Diamante é objeto de pesquisas devido às suas diferentes propriedades incluindo propriedades antibacterianas. No tratamento reabilitador com implantes, podem ocorrer complicações, proporcionando a infiltração de microrganismos orais para a interface Implante-Componente protético. O objetivo deste estudo foi avaliar propriedades de molhabilidade e energia livre de superfície a partir dos valores do ângulo de contato; propriedades antimicrobiana, de bioadesão e citotoxicidade de discos de titânio recobertos com DLC. Escherichia coli foi mantida em meio BHI a 37ºC por 3 h e 24 h para teste antimicrobiano. Para adesão, os discos foram mantidos em cultura de E. coli por 90 minutos a 37ºC e 20 minutos em ultrassom. A capacidade de prevenção na migração de bactérias para o interior da interface Implante-Componente protético foi realizado em implantes Hexágono Externo, conectados com torque de 32N e deixados em contato com E. coli por 24h, e Reação em Cadeia da Polimerase semi-quantitativo foi realizado para confirmação da esterilidade da técnica. Foram quantificados em UFC/mL em BHI Ágar para o teste antimicrobiano, adesão e infiltração bacteriana. Para citotoxicidade foi utilizado queratinócitos humanos (HaCat) cultivados em meio DMEM mantidos em atmosfera com 5% de CO2 a 37°C e avaliados pelo teste colorimétrico MTT. Os resultados de molhabilidade, teste antimicrobiano, teste de adesão e Infiltração bacteriana não apresentaram diferença estatisticamente significante entre os grupos. As superfícies de titânio e recobertas com DLC apresentaram uma leve diminuição na viabilidade celular com diferença estatisticamente significante ao grupo controle. O DLC apresenta-se como material biocompatível com leve grau de citotoxicidade que não modifica as propriedades de superfície, não apresenta propriedades antimicrobianas... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The study of DLC films is the subject of research due to their different properties including antibacterial properties. Rehabilitator in implant treatment, complications may occur, providing the infiltration of oral microorganisms for implant- abutmente interface. The aim of this study was to evaluate properties and wetting surface free energy from the values of the contact angle; antimicrobial properties bioadhesion and cytotoxicity of titanium discs coated with DLC. Escherichia coli was maintained on BHI at 37 ° C for 3 h and 24 h for antimicrobial test. For adhesion test, the discs were maintained in culture of E. coli for 90 minutes at 37 ° C and 20 minutes inside ultrasound. The ability to prevent the migration of bacteria into the implant - abutment interface was performed in dental implants External Hexagon connected with a torque of 32N and left in contact with E. coli for 24 h, and Polymerase Chain Reaction semi -quantitative was performed to confirm the sterility of the technique. Were quantified in CFU / ml in BHI agar for antimicrobial test, bacterial adhesion and infiltration. Cytotoxicity was performed using human keratinocytes ( HaCaT ) cultured in DMEM maintained in an atmosphere of 5% CO2 at 37 ° C and evaluated by the MTT colorimetric assay. The results of wettability, antimicrobial test, adhesion test and bacterial infiltration showed no statistically significant difference between the test groups. The surfaces of titanium and coated with DLC showed a slight decrease in cell viability with a statistically significant difference to the control group. The DLC is presented as biocompatible material with mild cytotoxicity without changing the surface properties, has no antimicrobial properties, does not interfere with bacterial adherence for E. coli and do not inhibit bacterial infiltration into the implant-abutment interface. / Mestre
|
328 |
A influência da Diabetes Mellitus no reparo de enxertos ósseos autógenos associados ou não à membrana colágena reabsorvível : estudo histomorfométrico em ratos /Meyer, Augusto Cesar de Andrade. January 2012 (has links)
Orientador: Maria Aparecida Neves Jardini / Banca: Mauro Pedrini Santamaria / Banca: Fernando Augusto Perrella / Resumo: O objetivo do presente estudo foi avaliar o processo de reparo ósseo do enxerto ósseo autógeno em bloco, em ratos diabéticos e verificar a influência da membrana colágena reabsorvível sobre este processo. Para tanto, foram utilizados 60 ratos adultos (Rattus norvegicus, variação albinus, Wistar) com sessenta dias de idade, com peso em torno de 200 gramas, que foram divididos em dois grupos experimentais, cada grupo contendo 30 animais: Grupo Teste (D), composto por ratos com Diabetes Mellitus induzida pela administração de aloxana e; Grupo Controle (C) composto por ratos normoglicêmicos. Foram considerados diabéticos os animais que apresentarem glicemia superior a 200 mg/dl. Todos os animais foram submetidos a enxertos na hemi-mandíbula direita e esquerda. Os enxertos na hemi-mandíbula do lado esquerdo foram recobertos por membrana de colágeno reabsorvível, propiciando o recobrimento de todo o bloco enxertado (C-ME e D-ME). Os enxertos realizados na hemi-mandíbula do lado direito foram realizados da mesma maneira, porém sem o recobrimento pela membrana de colágeno (C-E e D-E). A eutanásia dos animais foi realizada por perfusão cardíaca com formalina 4% nos períodos: 0 hora, 7, 14, 21, 45 e 60 dias. As peças foram desmineralizadas com solução de EDTA 10%, pH 7,4, e incluídAS em bloco de parafina e obtenção de cortes seriados com 5 m de espessura. A coloração utilizada foi Hematoxilina e Eosina para análise histológica e histomorfométrica, ambas realizadas em microscopia de luz. As estruturas analisadas foram: matriz óssea do leito receptor e enxerto, matriz óssea neoformada na interface leito receptor e enxerto e ao redor do enxerto, osteócitos, osteoblastos, tecido conjuntivo interposto entre leito receptor e enxerto. A análise histomorfométrica foi realizada... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the bone healing process of autogenous bone graft in diabetic rats and the influence of resorbable collagen membrane. For this purpose, it was 60 adult rats (Rattus norvegicus, Albinus variation, Wistar) sixty days old, weighing around 200 grams, which were divided into two experimental groups, each group containing 30 animals: Test Group (D), rats with diabetes mellitus induced by administration of alloxan and Control Group (C) normoglycemic rats. It was considered diabetic animals showing glucose levels above 200 md/dL. All animals underwent hemi-grafts surgery in the right and left jaws. The hemi-grafts in the left lower jaw were covered by resorbable collagen membrane, allowing the coating of the entire block graft (C-ME and D-ME). The hemi-grafts in the right jaw were performed the same way, but without covering the collagen membrane (C-E and D-E). The animals were euthanasied by cardiac perfusion with 4% formalin after: 0 hour, 7, 14, 21, 45 and 60 days. The pieces were demineralized in 10% EDTA solution, pH 7,4, and each peace was included in paraffin and obtained serial sections with 5 μm thick. The hematoxylin and eosin stain for histological and histomorphometric analysis. The parameters were analyzed: bone matrix graft and recipient bed, newly formed bone matrix at the interface graft and recipient bed and around the graft, osteocytes, osteoblasts, connective tissue interposed between the recipient bed and the graft. Histomorphometric analysis was performed using the computer program NIH Image J 1.35. The data were statistically analyzed using the computer program MINITAB (Minitab, version 14.12, 2004) with analysis of variance (ANOVA) and Tukey's test, both using the significance of 5%. The results showed that the diabetic rats exhibited at all periods, a greater amount... (Complete abstract click electronic access below) / Mestre
|
329 |
Efeito do extrato insaponificável de abacate e soja na doença periodontal induzida, na osseointegração de implantes e no reparo de defeitos críticos de calvaria de ratos /Oliveira, Guilherme José Pimentel Lopes de. January 2014 (has links)
Orientador: Rosemary Adriana Chiérici Marcantonio / Banca: Paulo Tambasco de Oliveira / Banca: Francisco Humberto Nociti Jr. / Banca: Valdir Gouveia Garcia / Banca: Joni augusto Cirelli / Resumo: Esse estudo teve como objetivo avaliar, em ratos, a influência da utilização do extrato de óleo insaponificável de abacate e soja (ASU) no reparo da periodontite induzida por ligaduras, na osseointegração de implantes e na integração de biomateriais osteocondutores. Para isso foram avaliadas as hipóteses de que o ASU poderia: 1)Aumentar o reparo da periodontite induzida; 2)Favorecer o reparo associado ao tratamento da periodontite induzida; 3)Acelerar a osseointegração; 4)Influenciar na integração de enxertos osteocondutores. Para a avaliação da primeira hipótese foram utilizados 84 ratos que foram submetidos a indução da periodontite por meio de ligaduras e que foram randomicamente divididos em 4 grupos: CTR: Administração do soro fisiológico(SS) no mesmo dia da indução da periodontite; ASU/-7: Administração de ASU iniciada 7 dias antes da indução de periodontite(0.6 mg/kg); ASU/0: Administração de ASU iniciada no dia da indução da periodontite; ASU/+7: Administração do ASU iniciada no dia da remoção da ligadura. As ligaduras, que foram inseridas bilateralmente nos segundos molares superiores, foram removidas após 7 dias e os medicamentos foram administrados diariamente por gavagem até o sacrifício dos animais (7, 15 e 30 dias). Foram realizadas análise microtomográfica (%volume ósseo), histomorfométricas (% osso na região da furca, distancias da junção cemento-esmalte(JCE) ao topo da crista óssea(CO) e a porção apical do epitélio juncional (aJE), imunohistoquímica (TRAP, RANKL e Fosfatase Alcalina) e de qPCR (IL1β, IL6, TNFα, RANKL e Fosfatase Alcalina). Para avaliação da segunda hipótese foram utilizados 84 ratos que foram submetidos a indução da periodontite por meio de ligaduras e que foram randomicamente divididos em 4 grupos: SRP-Administração de SS no dia do tratamento; SRP/ASU-7: Administração do ASU iniciada 7 dias antes da indução da periodontite(0.6 mg/kg); SRP/ASU0... / Abstract: The aim of this study was to evaluate in rats the effect of the avocado soybean unsaponifiables (ASU) on the bone repair in induced periodontitis, on the osseointegration of dental implants, and on the repair of the critical sized calvaria defects filled or no with biomaterials. For this purpose, the following hypothesis regarding the use of ASU were tested: 1)Improve the periodontal repair in induced periodontitis; 2)Improve the periodontal repair after the treatment of the induced periodontitis; 3) Accelerate osseointegration; 4) Improve the integration of osteoconductors bone grafts in the critical size calvaria defects. For the evaluation of the first hypothesis, eighty-four animals were randomly assigned into four equally-sized groups, receiving daily by gavage either sterile saline (CTR) or ASU (0.6 mg/kg), starting either 7 days prior to- (ASU/-7), or on the day- (ASU/0), or 7 days after (ASU/+7) periodontitis induction. Periodontitis was induced by placing silk ligatures into the gingival sulcus of the second maxillary molars for 7 days; thereafter the ligatures were removed. Seven animals from each group were euthanized at 7, 15 or 30 days after ligature removal. Bone resorption was evaluated by histomorphometry and micro CT. Immunohistochemistry was used to evaluate TRAP, RANKL, Alkaline phosphatase and qPCR to evaluate IL-1β, TNF-α, IL-6, RANKL, Alkaline phosphatase (AP). For the evaluation of the second hypothesis, periodontitis was induced in 84 rats via ligature placement around the second upper molar, which was removed after 7 days, and scaling was performed at this time. Subsequently, the rats were randomly allocated to four groups with 21 animals each: One in which saline solution (SS) was administered (SRP) and three in which ASU was administered (0.6 g/kg/day), beginning either 7 days before the induction of periodontitis (SRP/ASU-7), on the day of periodontitis induction (SRP/ASU0), or on the day of treatment... / Doutor
|
330 |
Estudo comparativo do Biogran® e Endobon® associados a implantes com defeitos periimplantares /Carvalho, Helen Ramon Esper de. January 2015 (has links)
Orientador: Osvaldo Magro Filho / Banca: Francisley Ávila de Souza / Banca: Celso Koogi Sonoda / Banca: Paulo Domingos Ribeiro Junior / Banca: Camila Tirapelli / Resumo: Introdução: A utilização de biomateriais em reconstruções para implantodontia tem sido amplamente discutida nos últimos anos. Proposição: O objetivo deste trabalho foi analisar o comportamento biológico do vidro bioativo (Biogran®) e do osso bovino (Endobon®) durante o processo de osseointegração associados a implantes com defeitos periimplantares em tíbias de rato. Material e método: Foram instalados 75 implantes na tíbia esquerda de 75 ratos Wistar machos. Os implantes foram divididos em três grupos experimentais. No Grupo 1 (Controle) foi provocado um defeito periimplantar monocortical circular e os implantes foram inseridos e deixados apenas com coágulo. No Grupo 2 os implantes foram inseridos com o mesmo defeito ósseo e o espaço preenchido com Biogran® e no Grupo 3 o espaço entre osso e implante foi preenchido com Endobon®. Os animais foram submetidos à eutanásia aos 14 e 42 dias e realizaram-se as análises histológica, histométrica (porcentagem de extensão linear de contato osso-implante - BIC e área óssea - BA), imunoistoquímica (expressão das proteínas osteocalcina - OC e osteopontina - OPN) e biomecânica (torque reverso). Resultados: Histologicamente todos os implantes encontraram-se osseointegrados. Não foram observadas diferenças estatisticamente significantes nos valores de torque reverso (p> 0,05) aos 42 dias. Para BIC, aos 14 dias foi de 8,29; 15,04; e 16,20%, para os grupos 1, 2 e 3, respectivamente. Aos 42 dias, os valores médios de BIC foram 30,84; 33,13; e 13,93% para os mesmos grupos, demonstrando que não houveram diferenças estatísticas entre grupos, porém com respostas diferentes entre períodos. Para a quantificação de formação óssea por área (BA), a resposta entre grupos difere. A resposta da BA média do Grupo 1 (18,75%) não difere da resposta média do Grupo 3 (21,62%). Porém, difere... / Abstract: Introduction: The use of biomaterials in reconstructions for dental implants has been widely discussed in recent years. Proposition: The aim of this work was to analize the biological behavior of the bioactive glass (Biogran®) and bovine bone (Endobon®) during the osseointegration process associated with implants with peri-implant defects in rat tibia. Material and Methods: 75 implants were installed in the left tibia of 75 male Wistar rats. The implants were divided into three experimental groups. In Group 1 (Control) was caused monocortical circular peri-implant defect and the implants were inserted and left only with clot. In Group 2 implants were inserted with the same bone defect and the space filled with Biogran® and in Group 3 the space between bone and implant was filled with Endobon®. The animals were euthanized at 14 and 42 days and there were the histological analysis, histometric (percentage of linear extension bone-implant contact - BIC and bone area - BA), immunohistochemistry (expression of the proteins osteocalcin - OC and osteopontin - OPN) and biomechanics (reverse torque). Results: Histologically all implants were osseointegrated. No statistically significant differences were observed in the values of reverse torque (p> 0.05) at 42 days. For BIC, at 14 days was 8.29; 15.04; and 16.20% for the groups 1, 2 and 3, respectively. After 42 days, the BIC values were 30.84; 33.13; and 13.93% for the same groups, demonstrating that there were no statistical differences between groups, but with different responses between periods. For the quantification of bone formation per area (BA), the response differs between groups. The average BA response in Group 1 (18.75%) did not differ from the average Group 3 response (21.62%). However, different from Group 2 (34.73%). The immunohistochemical results were analyzed by Qualitative... / Doutor
|
Page generated in 0.064 seconds