• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Evaluation of psychrotrophic anaerobic digestion of food waste / Utvärdering av psykrotrofisk anaerob nedbrytning av matavfall

Buenos, Albert January 2024 (has links)
Anaerob nedbrytning vid låg temperatur är ett energieffektivt system, men få studier har fastställt kinetiken för anaerob nedbrytning av matavfall vid dessa temperaturer. I denna studie bestämdes kinetiken för en anaerob rötkammare för matavfall med mesofil inokulum vid 20°C. Effekten av acklimatiseringstiden avslöjades. Därefter användes biokol och spårämnen för att utvärdera deras inverkan vid 20°C. Det visade sig att tillsats av spårämnen ökade kinetiken upp till 114% av kontrollreaktorn. Denna studie visade att olika biokol har varierande effekt på kinetiken (här negativ och neutral effekt). De kinetiska värdena utvärderades med en första ordningens modell och användes för att uppskatta en virtuell fabrik. Med ett inflöde på 27 000 ton bioavfall/år och 80 % av den maximala metanpotentialen ansågs en psykrofil i ett steg vara orealistiskt (hydraulisk retentionstid (HRT): 9,6 månader med den experimentella kinetiken). Lovande resultat kan dock uppnås med en lämplig kombination av utetemperatur och substrattemperatur. / Low temperature anaerobic digestion is an energy efficient system, however few studies have determined the kinetics of the anaerobic digestion of food waste at those temperatures. This study determined the kinetics of a food waste anaerobic digestor with mesophilic inoculum at 20°C. The impact of acclimatation time was revealed. Then biochar and trace elements were employed to evaluate their impact at 20°C. It was shown that addition of the trace elements boosted the kinetic up to 114% of the control reactor. This study proved that different biochars have variable effect on the kinetics (here negative and neutral effect). The kinetic values were evaluated with a first order model and used to estimate a virtual factory. With 27 000 tons of biowaste /year influx and 80% expression of the maximum methane potential, a single stage psychrophilic was deemed unrealizable (Hydraulic Retention Time (HRT): 9.6 month with the experimental kinetics). However, promising results can be obtained with an adequate exterior temperature & substrate temperature couple.
2

Comparing the Effects of Flexibility Options on Conventional and Low-temperature District Heating Networks : Studying the potential of the next generation of district energy systems

Nithyanathan, Mario January 2022 (has links)
District heating (DH) systems have been commonplace in Europe for over a century. These systems have undergone an evolution since their conceiving, and today we are at the precipice of the next major transition from the third-generation district heating system (3GDH) to the fourth generation (4GDH). Current 3GDH systems operate at a supply temperature in-between 80 °C - 100 °C and a return temperature of around 45 °C. Future 4GDH systems will operate at a supply temperature below 70 °C and return temperature as low as 25 °C, and therefore, will integrate waste heat available at low temperatures, and renewable heat sources.The literature review performed here shows that low temperature DH (LTDH) systems have several benefits over their conventional temperature DH (CTDH) predecessor and achieve lower operating costs for some technologies when compared to the CTDH alternative. Therefore, in this thesis, a TIMES (The Integrated MARKAL-EFOM System) model is used to simulate the operation of a DH system. The learnings from the literature review were incorporated into the model so that certain operational differences between CTDH and LTDH systems could be compared.In this context, the aim of this project is to analyse the effects of flexibility options on the operation of a DH system, and to compare these effects between CTDH and LTDH systems. Flexibility options in DH systems are technologies and concepts that work towards balancing heat generation and demand in thermal grids and can also help balance power generation and demand in electrical grids. Examples of flexibility options are thermal energy storage (TES) tanks, and seasonal energy storages (e.g., borehole TES (BTES), caverns (CTES), and pits (PTES)). These flexibility options have already been implemented in varying amounts in today’s CTDH systems and will therefore have to provide the same service with LTDH systems in the future.As part of the REWARDHeat project (grant agreement No. 857811), the Swedish city of Helsingborg was used as the case-study in this thesis. The city’s heating sector was incorporated into a TIMES heat model and simulated for the period 2017 to 2052. The existing CTDH system model was then adapted to a LTDH system model and simulated for the same time horizon. Both the CTDH model and LTDH model were simulated for a case with TES available and then for a case where TES was not available, to better-identify the flexibility benefits. The effect of electricity prices on the operation of the system was also studied, where one case uses electricity prices that are on the conservative (i.e., higher) side and another on the ambitious (i.e., lower) side. This means that a total of eight scenarios were simulated and analysed.The results show that more heat storage capacity is utilised in the LTDH system due to TES technologies having lower heat losses. Also, it was found that peak shaving was more pronounced in the LTDH system. This is due to more base heat supply in the system from more excess heat, and from STES discharging. This means that the required installed capacity of heat generating technologies are lower compared to the CTDH alternative. This all translates to TES technologies facilitating greater savings in total system cost, by almost 10%, in the LTDH system. The CTDH and LTDH systems studied in this thesis (i.e., with and without TES) are seen to transition from being a net electricity generator to being a major electricity consumer. This is due to reducing electricity prices going into the future, which incentivise investments into heat pumps (HPs), eventually making the systems (with combined heat and power (CHP) plants in the mix in the earlier years) HP-dominated. The inclusion of TES technologies is shown to accelerate this transition in both CTDH and LTDH systems studied in this thesis. More electricity is generated in the CTDH system than in a LTDH system as the cost savings from running HPs (due to higher coefficients of performance (COP) in low-temperature operation) offsets the revenue from electricity sales.Finally, the effect of electricity prices is also seen in the results. Lower electricity prices favour more DH production from HPs, while higher electricity prices incentivise increased production from CHP plants. The results show that the CTDH system gives the network operator more freedom (than in the LTDH system) to respond to electricity prices.Therefore, to conclude, LTDH systems can make more use of the flexibility provided by TES technologies due to lower heat losses, as shown through DH production volumes being lower, and through more peak shaving.Similar studies in future could incorporate a sensitivity analysis on the COPs of HPs in LTDH systems, given that this parameter seems to greatly influence the cost optimised strategy for operating DH systems. Also, it may be beneficial to expand the study into incorporating the city’s power sector, which would mean incorporating the electricity demand into the model. It would be interesting to see if this would cause the model to invest in other technologies other than HPs, or if it might still make more financial sense to import the electricity at market prices. Finally, the cost of transitioning from a CTDH system to a LTDH system could also be considered in the model, as it was not the case in this project. This would probably show that the financial benefit of LTDH systems is less than what is predicted in this study. / Fjärrvärmesystem har varit vanliga i Europa i över hundra år. Dessa system har utvecklats sedan de utformades, och idag står vi inför nästa stora övergång från tredje generationens fjärrvärmesystem (3GDH) till fjärde generationen (4GDH). Dagens 3GDH-nät fungerar med en framledningstemperatur mellan 80 °C och 100 °C och en returtemperatur på cirka 45 °C. Framtida 4GDH-nät kommer att fungera vid en framledningstemperatur under 70 °C och en returtemperatur så låg som 25 °C, och kommer därför att integrera spillvärme som är framkomlig vid låga temperaturer och förnybara värmekällor.Litteraturstudien som gjorts i den här studien visar att fjärrvärmenät med låg temperatur har flera fördelar jämfört med deras föregångare med konventionell temperatur och att driftskostnaderna för vissa tekniska system är lägre än för alternativet med konventionell temperatur. I denna avhandling används därför en TIMES-modell (The Integrated MARKAL-EFOM System) för att simulera driften av ett fjärrvärmesystem. Lärdomarna från litteraturstudien användes i modellen för att vissa driftskillnader mellan dessa två system så att de kunde jämföras. I detta sammanhang är syftet med detta projekt att analysera effekterna av flexibilitetsalternativ på driften av ett fjärrvärmesystem och att jämföra dessa effekter mellan konventionella temperaturer och lågtemperaturssystem. Flexibilitetsalternativ i fjärrvärmenät är teknologi och koncept som arbetar för att balansera värmeproduktionen och efterfrågan i termiska nät och som också kan bidra till att balansera elproduktionen och efterfrågan i elnätet. Exempel på flexibilitetsalternativ är lagringstankar av värmeenergi och säsongsbundna energilägen (till exempel lagring av värmeenergi i borrhål, grottor och gropar). Dessa flexibilitetsalternativ har redan införts i varierande omfattning i dagens fjärrvärmenät och kommer därför att användas med lågtemperaturnät i framtiden.Som en del av REWARDHeat-projektet (bidragsavtal nr 857811) användes den svenska staden Helsingborg som fallstudie i denna studie. Stadens värmesektor införlivades i en TIMES-värmemodell och simulerades för perioden 2017–2052. Den befintliga fjärrvärmenät modellen med konventionell temperatur anpassades sedan till en fjärrvärmenätmodell med låg temperatur och simulerades för samma tidsperiod. Båda modellerna simulerades för ett fall där värmeenergilagring var tillgänglig och sedan för ett fall där värmeenergilagring inte var tillgänglig, för att bättre identifiera flexibilitetsfördelarna. Effekten av elpriserna på systemets funktion undersöktes också, där ett fall använder elpriser som är på den konservativa (dvs. högre) sidan och ett annat på den ambitiösa (dvs. lägre) sidan. Detta innebär att totalt åtta scenarier simulerades och analyserades.Resultaten visar att mer värmelagringskapacitet utnyttjas i fjärrvärmesystemet med låg temperatur på grund av att tekniken för lagring av värmeenergi har mindre värmeförluster. Det konstaterades också att lastutjämning var mer i fjärrvärmesystemet med låg temperatur. Detta beror på att det finns mer grundvärme i systemet på grund av mer överskottsvärme och på att värmeenergilagringar i borrhålen laddas ur. Detta innebär att den installerade kapacitet som krävs för värmeproducerande teknologi är lägre jämfört med alternativet med konventionell temperatur. Allt detta innebär att tekniken för lagring av värmeenergi möjliggör större besparingar i den totala systemkostnaden, med nästan 10 %, i fjärrvärmesystemet med låg temperatur. De konventionella och lågtemperatur fjärrvärmesystem som studeras i denna avhandling (dvs. med och utan lagring av värmeenergi) övergår från att vara nettogeneratorer av el till att bli stora elkonsumenter. Detta beror på att elpriserna kommer att sjunka i framtiden, vilket ger incitament till investeringar i värmepumpar, vilket i slutändan gör att systemen (som har haft kraftvärmeverk i mixen under tidigare år) kommer att domineras av värmepumpar. Införandet av tekniken för värmeenergilagring visar sig påskynda denna övergång i båda de system som studeras i denna avhandling. Det produceras mer el i fjärrvärmesystemet med konventionell temperatur än i ett fjärrvärmesystem med låg temperatur, eftersom kostnadsbesparingarna från drift av värmepumpar (på grund av högre prestandakoefficienter) med låg temperatur uppväger intäkterna från elförsäljning.Slutligen syns också effekten av elpriserna i resultaten. Lägre elpriser gynnar mer värmeproduktion från värmepumpar, medan högre elpriser stimulerar ökad produktion från kraftvärmeverk. Resultaten visar att fjärrvärmesystemet med konventionell temperatur ger nätoperatören större frihet (än i fjärrvärmesystemet med låg temperatur) att reagera på elpriserna.Sammanfattningsvis kan man därför konstatera att fjärrvärmesystem med låg temperatur i högre grad kan utnyttja den flexibilitet som tekniken för värmeenergilagring ger på grund av lägre värmeförluster, vilket visas genom att produktionsvolymerna för fjärrvärme är lägre och genom en högre grad av lastutjämning.Liknande studier i framtiden skulle kunna omfatta en känslighetsanalys av värmepumparnas prestandakoefficient i fjärrvärmesystem med låg temperatur, eftersom denna parameter verkar ha stor betydelse för den kostnadsoptimerade strategin för driften av systemet. Det kan också vara fördelaktigt att utvidga studien till att omfatta stadens energisektor, vilket skulle innebära att elbehovet inkluderas i modellen. Det skulle vara intressant att se om detta skulle få modellen att investera i andra tekniker än värmepumpar, eller om det fortfarande skulle vara mer ekonomiskt fördelaktigt att importera el till marknadspris. Slutligen skulle kostnaden för att övergå från ett fjärrvärmenät med konventionell temperatur till ett fjärrvärmenät med låg temperatur också kunna beaktas i modellen, eftersom så inte var fallet i detta projekt. Detta skulle förmodligen visa att den ekonomiska fördelen med fjärrvärmenät med låg temperatur är mindre än vad som förutses i denna studie.
3

Low temperature embrittlement of duplex stainless steels : A study of alloying elements’ effect

Lai, Libang January 2020 (has links)
Duplex stainless steels (DSSs), consisting of an equal amount of ferrite and austenite phases, have wide applications in e.g. vehicles, chemical engineering as well as nuclear plant  because  of  the  combination  of  excellent  mechanical properties  and  corrosion resistance.  However,  low  temperature  embrittlement has  existed  for  a  few  decades restricting the application of DSSs over about 250 ºC. When the service temperature ranges from around 250 to 500 °C, DSSs would become brittle because of the phase separation in the ferrite  phase. The phase separation is the  main reason  for the  low temperature embrittlement, and the kinetic of this phase separation achieves the fastest rate at about 475°C, so it is also termed as ‘475°C embrittlement’. Plenty of research has been performed in this field, but the problem remains. The mechanism of phase separation is due to the existence of a miscibility gap in the iron  chromium  binary  system,  and  previous  research  has  reported  some alloying elements can have the potency to delay the phase separation and the goal of my thesis is to investigate the influence of different alloying elements and select one which could be a plausible one to retard phase separation, and subsequently try to mitigate the low temperature embrittlement problem of DSSs. This  work  includes  the  literature survey  of  different  alloying  elements  which could influence   the   microstructure   and   mechanical   properties   of   DSSs   in general. Subsequently the thermodynamic calculation was performed to identify the effect of the  selected  alloying  elements  addition  on  phase  formation during  heat  treatment. Vanadium was selected to be a potentially suitable alloying element to be added into DSSs and experimental investigations were performed on the heat treatment process and the effect of V alloying. The main conclusions of the proposed thesis can be drawn as follow: The elemental addition  of Al,  Si, V,  Nb  and Ti  are  calculated  by Thermo-Calc,  they are  all  ferrite stabilisers and V addition seems most likely to be effective due its combination with the  interstitial  elements  C  and  N.  In  the  experimental  part, vanadium  additions combined with intermediate temperature solution treatment could be effective to retard the age hardening effect and the impact toughness test has a consistent tendency. Also, according to Thermo-Calc calculations and experimental results, the more interstitial elements that combine with V and precipitate from the ferrite phase the better was the performance of the duplex stainless steels. / Duplexa rostfria stål (DSS), bestående av lika stor mängd ferrit- och austenit, har bredtillämpning inom t.ex. fordon, kemiteknik samt kraftverk på grund av kombinationen av utmärkta mekaniska egenskaper och korrosionsbeständighet. Försprödning vid låg temperatur   begränsar emellertid tillämpningen   av   DSS   över   250   °C.   När driftstemperaturen varierar från cirka 250 till 500 ° C så kan DSS bli spröda på grund av   fasseparation   i   ferritfasen.   Fasseparationen   är   den    främsta   orsaken   till lågtemperaturförstöring, och kinetiken för denna fasseparation uppnår den snabbaste hastigheten  vid  cirka  475  °C,  så  den  kallas  också  '475  °C-försprödning'.  Mycket forskning har utförts inom detta område, men problemet kvarstår. Mekanismen för fasseparation beror på förekomsten av ett blandningslucka i det binära järn-krom-systemet, och tidigare forskning har rapporterat att vissa legeringselement kan  ha  förmågan  att  fördröja  fasseparationen.  Målet med mitt  examensarbete  är  att undersöka påverkan av olika legeringselement och välja ett som kan användas för att fördröja fasseparationen och därav mildra problemet med lågtemperaturförsprödning hos DSS. Detta  arbete  inkluderar  litteraturundersökning  av  olika  legeringselement som  kan påverka  mikrostrukturen  och  mekaniska  egenskaper  hos  DSS  i allmänhet.  Därefter termodynamiska beräkningar för att identifiera effekten av de valda legeringselementen på fasjämvikt under värmebehandlingen. Vanadin valdes som ett potentiellt lämpligt legeringselement som kan tillsättas i DSS. Experimentella undersökningar utfördes på värmebehandlingsprocessen och effekten av V-legering. De huvudsakliga slutsatserna av examensarbetetär: tillsatsen av Al, Si, V, Nb och Ti beräknades av Thermo-Calc, de är alla ferritstabiliserande och V-tillsats verkar kunna vara effektiv på grund av dess kombination med de interstitiella elementen C och N. I den    experimentella    delen    studerades vanadintillsatser    i    kombination    med värmebehandling för att fördröja den hårdnandet och försprödningen. Enligt Thermo- Calc-beräkningar  och experimentella  resultat  så  kan  prestanda  förbättras  desto  merinterstitiella element som kombineras med V.
4

Denitrification in a Low Temperature Bioreactor System : Laboratory column studies

Nordström, Albin January 2014 (has links)
Denitrification is a microbially-catalyzed reaction which reduces nitrate to N2 through a series of intermediate nitrogen compounds. Nitrate is a nutrient and its release into the environment may lead to eutrophication, depending on the amount that is released and the state of the recipient. The release of nitrate from the mining industry in Kiruna (Sweden) has been identified as an eutrophication risk, and a denitrifying bioreactor is to be constructed at the site to reduce the nitrate release.Since the denitrification rate decreases with temperature and the temperature in Kiruna during large parts of the year drops below 0˚C, the denitrifying bioreactor therefore has to be designed for the site-specific environment in terms of flow rate and hydraulic residence time. Laboratory column studies are used to study and determine the nitrate removal rate in a low temperature environment (5˚C) with pine wood chips as reactive matrix/ electron donor; the input solution had an average concentration of 35 mg NO3-N/L and a high sulfate concentration. Nitrate removal was studied as a function of hydraulic residence time and temperature. Parameters that were monitored include pH, alkalinity and concentrations of ammonium, nitrite and sulfate in the effluent from the columns. On three occasions, samples were gathered along the flow path in the columns (concentration profiles) such that changes in nitrate, nitrite, and occasionally ammonium concentration could be studied in relation to each other. The study concluded that a denitrifying bioreactor utilizing pine wood chips as the reactive matrix is a suitable option for nitrate treatment in a low temperature (5˚C) environment. Under the conditions of the study, effluent nitrate, nitrite, and ammonium concentrations are below limits established in legislation. Nitrate removal rates are given for zero-order nitrate reduction and overall first-order nitrate reduction, as the concentration profiles revealed a decrease in nitrate removal rate as nitrate concentration dropped below 3 mg NO3-N/L. / Nitrat är ett näringsämne som kan orsaka övergödning vid utsläpp, beroende på halterna och recipienten. Växterna som tar upp kväve kommer så småningom att dö och sjunka mot botten där de förmultnar. Förmultningen kräver syre, och vid ökad växtlighet så ökar även konsumtionen av syre då det finns mer organiskt material att bryta ned. Detta leder i slutändan till syrefria områden, där djurliv och växtlighet är mer begränsade. Nitratutsläpp från gruvindustrin i Kiruna har blivit identifierad som en potentiell övergödningsrisk och en denitrifierande bioreaktor ska därmed installeras för att minska utsläppen. Denitrifikation är en mikrobiell reaktion som reducerar nitrat till kvävgas genom en serie av intermediära kväveföreningar. En denitrifierande bioreaktor använder sig utav denitrifikation för att minska nitratkoncentrationer i vatten som passerar genom bioreaktorn som består av huvudsakligen; (1) bakterierna som sköter denitrifikationen, och (2) en kolkälla som fungerar som ”mat” till de denitrifierande bakterierna, Hastigheten varvid nitrat omvandlas till kvävgas genom denitrifikation, minskar med temperatur och den denitrifierande bioreaktorn måste därmed anpassas till omgivningen där den ska placeras med avseende på uppehållstid i reaktorn. Uppehållstiden måste vara tillräcklig för att minska nitratkoncentrationen till önskad nivå, men samtidigt så får uppehållstiden inte vara för lång då andra ämnen kan reagera och bilda ofördelaktiga produkter vid låga nitratkoncentrationer. Kolonnstudier i en låg-tempererad miljö (5˚C) är ett första steg för att studera hastigheten av nitratförbrukning i en sådan omgivning, och används i detta arbete med träflis av tall som kolkälla. Parametrar som påverkar, och varierar som ett resultat av, denitrifikation (exempelvis pH och sekundära föroreningar) övervakas. Hastigheten av nitratförbrukning som fås från kolonnstudierna kan sedan används som riktlinjer för konstruktionen av en denitrifierande bioreaktor i fältskala i Kiruna. Studiens slutsats är att en denitrifierande bioreaktor med träflis av tall som reaktivt medium är ett fungerande alternativ för nitrat reducering i en lågtempererad miljö (5˚C) då nitrat effektivt reduceras till under gränsvärden fastslagna i lag. Även andra potentiella biprodukter (exempelvis nitrit och ammonium) som kan resultera från den miljö som den denitrifierande bioreaktorn ger upphov till är under de gränsvärden som finns fastslagna i lag.
5

Högtempererat borrhålslager för fjärrvärme / High Temperature Borehole Thermal Energy Storage for District Heating

Hallqvist, Karl January 2014 (has links)
The district heating load is seasonally dependent, with a low load during periods of high ambient temperature. Thermal energy storage (TES) has the potential to shift heating loads from winter to summer, thus reducing cost and environmental impact of District Heat production. In this study, a concept of high temperature borehole thermal energy storage (HT-BTES) together with a pellet heating plant for temperature boost, is presented and evaluated by its technical limitations, its ability to supply heat, its function within the district heating system, as well as its environmental impact and economic viability in Gothenburg, Sweden, a city with access to high quantities of waste heat. The concept has proven potentially environmentally friendly and potentially profitable if its design is balanced to achieve a good enough supply temperature from the HT-BTES. The size of the heat storage, the distance between boreholes and low borehole thermal resistance are key parameters to achieve high temperature. Profitability increases if a location with lower temperature demand, as well as risk of future shortage of supply, can be met. Feasibility also increases if existing pellet heating plant and district heating connection can be used and if lower rate of return on investment can be accepted. Access to HT-BTES in the district heating network enables greater flexibility and availability of production of District Heating, thereby facilitating readjustments to different strategies and policies. However, concerns for the durability of feasible borehole heat exchangers (BHE) exist in high temperature application. / Värmebehovet är starkt säsongsberoende, med låg last under perioder av högre omgivningstemperatur och hög last under perioder av lägre omgivningstemperaturer. I Göteborg finns en stor mängd spillvärme tillgängligt för fjärrvärmeproduktion sommartid när behovet av värme är lågt. Tillgång till säsongsvärmelager möjliggör att fjärrvärmeproduktion flyttas från vinterhalvår till sommarhalvår, vilket kan ge såväl lönsamhet som miljönytta. Borrhålsvärmelager är ett förhållandevis billigt sätt att lagra värme, och innebär att berggrunden värms upp under sommaren genom att varmt vatten flödar i borrhål, för att under vinterhalvåret användas genom att låta kallt vatten flöda i borrhålen och värmas upp. I traditionella borrhålsvärmelager används ofta värmepump för att höja värmelagrets urladdade temperatur, men på grund av höga temperaturkrav för fjärrvärme kan kostnaden för värmepump bli hög. I denna rapport föreslås ett system för att klara av att nå höga temperaturer till en lägre kostnad. Systemet består av ett borrhålsvärmelager anpassat för högre temperaturer (HT-BTES) samt pelletspannor för att spetsa lagrets utgående fluid för att nå hög temperatur. Syftet med rapporten är att undersöka potentialen för detta HT-BTES-system med avseende på dess tekniska begränsningar, förmåga till fjärrvärmeleverans, konsekvenser för fjärrvärmesystemet, samt lönsamhet och miljöpåverkan. För att garantera att inlagringen av värme inte är så stor att priset för inlagrad värme ökar väsentligt, utgår inlagringen från hur mycket värme som kyls bort i fjärrvärmenätet sommartid. I verkligheten finns betydligt mer värme tillgänglig till låg kostnad. När HT-BTES-systemet producerar fjärrvärme, ersätts fjärrvärmeproduktion från andra produktionsenheter, förutsatt att HT-BTES-systemets rörliga kostnader är lägre. I Göteborg ersätts främst naturgas från kraftvärme, men också en del flis. Kostnadsbesparingen beror på differensen för total fjärrvärmeproduktionskostnad med och utan HT-BTES-systemet. Undersökningen visar att besparingen är större om HT-BTES-systemet placeras i ett område där det är möjligt att mata ut fjärrvärme med lägre temperatur. Om urladdning från HT-BTES kan ske med hög temperatur ökar också besparingen. Detta sker om lagrets volym ökar, om avståndet mellan borrhål minskar eller om värmeöverföringen mellan det flödande vattnet i borrhålen och berggrunden ökar. Dessa egenskaper för lagret leder också till minskade koldioxidutsläpp. Storleken på besparingen beror dock i hög grad på hur bränslepriser utvecklas i framtiden. Strategiska fördelar med HT-BTES-systemet inkluderar; minskad miljöpåverkan, robust system med lång teknisk livslängd (för delar av HT-BTES-systemet), samt att inlagring av värme kan ske från många olika produktionsenheter. Dessutom kan positiva bieffekter identifieras. Undersökningen visar att HT-BTES-systemet har god potential att ge lönsamhet och minskad miljöpåverkan, och att anläggning och drift av lagret kan ske utan omfattande lokal miljöpåverkan. Det har också visats att de geologiska förutsättningarna för HT-BTES är goda på många platser i Göteborg, även om lokala förhållanden kan skilja sig åt. För att nå lönsamhet för HT-BTES-systemet krävs en avvägning på utformning av lagret för att nå hög urladdad temperatur utan att investeringskostnaden blir för stor. Undersökningen visar att om anslutning av HT-BTES-systemet kan ske mot befintlig anslutningspunkt eller till befintlig värmepanna kan investeringskostnaden minska och därmed lönsamheten öka. Placering av HT-BTES-systemet i områden med risk för överföringsbegränsningar kan också minska behovet av att förstärka fjärrvärmenätet, och således bidra till att minska de kostnader som förstärkning av nätet innebär. Betydelsefulla parametrar för att nå lönsamhet för HT-BTES-system inkluderar dessutom kostnaden för inlagrad värme liksom vilket vinstkrav som kan accepteras. Tillgång till HT-BTES möjliggör ökad nyttjandegrad och flexibilitet för fjärrvärmeproduktionsenheter, och därmed ökad anpassningsmöjlighet till förändrade förutsättningar på värmemarknaden. Dock återstår att visa att komponenter som klarar de höga temperaturkraven kan tillverkas till acceptabel kostnad.

Page generated in 0.0757 seconds