Spelling suggestions: "subject:"luftkvalité"" "subject:"luftkvalitén""
1 |
Kartläggning av ventilationssystem på gymnasieskola : Analys av prestanda och energianvändning hos ventilationssystemWestman, Kristian January 2021 (has links)
Having the right surroundings and physical conditions in a workplace is crucial for ones ability to accomplish a job efficiently and staying physically and mentally healthy at the same time. A often overlooked part of public workplaces is the air quality and overall function of the ventilationsystem, which can make a substantial difference for the well-being of staff. In this study, the ventilationsystem of Rodengymnasiet, a high school in Norrtälje municipality has been examined and evaluated since staff at the school have some complains regarding the air quality at their workplace. The study was conducted through preliminary reviews of blueprints for the building and discussion with the staff about specifics for their complaints, where most complaints were related to uncomfortable temperatures in offices. Then measurements of humidity, air temperature and CO₂-levels were taken in several offices and classrooms during regular workdays with normal attendance. This, in combination with visual inspection of the ventilationsystem and reviewing of the latest results of inspection gave the results that no obvious faults in the ventilation seem to exist, and thusly the complaints and feelings of uncomfortableness seem to not stem from flawed ventilation. A simplified estimation of the ventilationsystem energy usage was also made from the information available and inspected state of the components in the system. The most important conclusion made from these results is that Rodengymnasiet seem to have a very well functioning ventilationsystem, and the suggestions made in this study only serve to add a small degree of optimization to a already well constructed and well maintained system.
|
2 |
Simulation of air quality in underground train stations / Simulering av luftkvalité i underjordiska tågstationerSöderberg, Benjamin January 2020 (has links)
Particulate matter (PM) is a widespread air pollutant of microscopic particles that are suspended in the atmosphere. There is high concentration of PM in underground train stations and tunnels. The concentration of particulate matter (PM10) measured in Stockholm’s metro varies significantly between day and nighttime traffic of trains. Emission factors are a representative value of a pollutant released into the atmosphere. These factors can be expressed as the weight of pollutant divided by a unit distance, volume, or weight. In this document it is expressed as the amount of energy used to produce a unit weight. Such factor expresses estimation of emissions from train wheel-rail contact and brake. Simulation of particulate matter using IDA tunnel was conducted to evaluate and predict particulate matter (PM10) concentration levels. Previous measured data of PM10 from Mariatorget’s platform (performed by SLB analysis) was used for the validation of the simulation model. These data were collected during winter and summer periods. It was then used as fundamental reference to simulate and calibrate emission factors. Important parameters of the tunnel, platform and trains that were used in traffic were imported. There are ventilation shafts on each end of the platform. These ventilation shafts are open fully during summer and closed during winter periods. Thus, two case scenarios, winter and summer were investigated. The results obtained were later evaluated and analysed. Sensitivity analysis was made to test the effect of ventilation shaft’s openings on emission factors. The results from winter case study showed that emission factors are 0.57 g/kWh from wheel-rail contact and 0.031 g/kWh from brakes. Emission factors from wheel-rail contact give 70% of the measured PM10 concentration whereas brakes give 30% of PM10 concentrations. Results obtained from summer case study showed that emission factors are 0.61 g/kWh and 0.05 g/kWh from wheel-rail contact as well as from brakes, respectively. / Partiklar är en utbredd luftföroreningar av mikroskopiska partiklar som finns i luften. Det finns höga halter av PM (particulate matter) i underjordiska tågstationer och tunnlar. Partikelhalten (PM10) som är uppmätt i Stockholms tunnelbana varierar betydligt mellan dag- och natttågtrafik. Emissionsfaktorn är ett representativt värde för mängden partiklar som släpps ut i atmosfären. Dessa faktorer kan uttryckas som massan av partikel per enhetsavstånd, volym eller vikt. I detta dokument uttrycks detta som den mängd energi som går åt för att producera enhetsviktspartiklar. Faktorn uttrycker en uppskattning av partikelemissioner från hjul-rälskontakt och broms. Simulering har genomfördes i IDA tunnel för att utvärdera och förutsäga partikelhalten på tågplattformar. Tidigare uppmätta data under vinter och sommar från Mariatorgets plattform (utförd av SLB-analys) användes för validering av simuleringsmodellen. Detta användes sedan som grundläggande referens för att simulera och kalibrera emissionsfaktorer. Viktiga parametrar för tunneln, plattformen och tågen som användes i trafiken är inhämtade och evaluerade. Ventilationsschakt finns i varje ände av plattformen. Dessa ventilationsschakt är öppna under sommaren och stängda under vinterperioden. Således undersöktes två scenarier, vinter- och sommarfall. De erhållna resultaten utvärderades och analyserades senare. Känslighetsanalys gjordes för att testa effekten på emissionsfaktorerna av ventilationsschaktens öppningsgrad. Resultaten från vinterfallstudien visade att emissionsfaktorerna är 0,57 g/kWh från hjul-rälkontaktoch 0,03 g/kWh från bromsarna. Emissionsfaktorn från hjul-rälkontakten ger 70 % av den uppmätta PM10 koncentrationen, medan bromsarna ger 30 %. Resultaten från sommarfallstudien visade att emissionsfaktorerna är 0,61 g/kWh och 0,05 g/kWh från hjul-rälkontakten och bromsarna, respektive.
|
3 |
Undersökning av luftkvaliteten vid småskalig biobränsleförbränning i två kommuner med modellsystemet VEDAIRAndersson, Stefan January 2007 (has links)
<p>An Internet application, VEDAIR, for estimation of air quality in regions with small-scale combustion of bio fuel has been developed by Swedish Meteorological and Hydrological Institute with financing from Swedish Energy Agency and Swedish Environmental Protection Agency. The model contains user interface and a coupled model concept where concentrations of atmospheric pollutions are calculated for regional, urban and local contributions. In this report the model is described and a first study of air quality considering PM10 (particles with a diameter less than 10 µm) in two Swedish municipalities, Vänersborg and Gnosjö, is introduced.</p><p>According to the result, there are areas with poor air quality even in smaller Swedish municipalities, mostly due to high emission from buildings with older wood heating furnace without hydraulic accumulator.</p><p>In Vänersborg three areas were analysed in VEDAIR for the year 2003: Vargön, Mariedal and the downtown district. In the whole municipality the upper evaluation threshold for PM10, which is defined as 14 µg/m3 for annual average, was exceeded due to background contribution of particles. In all areas, however, the concentrations of PM10 were less than the environmental quality norms. In Vargön, where wood heating furnaces are commonly used, in some areas the concentration of particles was as big as or bigger than the downtown district (annual average of 20 µg/m3). However, in downtown the pollutants were more spread. Biggest concentrations of PM10 were estimated in Mariedal, due to emissions from older wood heating furnaces and streets, mostly in areas with unfavourable meteorological conditions. Measurements of PM10 in the area are therefore suggested. Biggest concentrations of PM10 were prevailed during winter, due to great heating need in combination with cooler air temperature and more stable stratification. The local contribution of PM10 was negative correlated with temperature. In the downtown district, however, the biggest concentrations of PM10 were obtained during spring due to usage of studded tyres.</p><p>In Gnosjö the air quality considering PM10 was analysed in the areas Götarp, downtown and Gårö. Calculations in VEDAIR showed that the emissions from traffic were much less than wood heating furnace. The background annual average of PM10 in Gnosjö was 1 µg/m3 higher than Vänersborg. The air quality was quite equal as in Vänersborg, but there was an area in Gårö where the environmental quality norms considering PM10 almost were exceeded, this mostly due to emission from one building with high heating need.</p><p>In this study a comparison between calculated concentrations of PM10 with measured concentrations in Gnosjö for the period 3 November to 31 December 2003 was also made. The validation showed that VEDAIR underestimated the concentrations, but the result was anyway reasonable. Before, validations have only been performed for the northern part of Sweden, and this study indicates that VEDAIR also estimates concentrations of PM10 sufficiently well in southern part of Sweden.</p><p>The study also showed that if a house owner would replace an old wood heating furnace by a modern furnace with hydraulic accumulator, the annual average of the concentration of PM10 could decrease by 4 µg/m3 which is a reduction of 25%.</p> / <p>Ett internetverktyg, VEDAIR, för bedömning av luftkvalitet vid småskalig förbränning av biobränsle har utvecklats av SMHI med finansiering från bland andra Energimyndigheten och Naturvårdsverket. Modellen består av användargränssnitt och ett kopplat modellsystem där halterna av luftföroreningar beräknas för såväl regionala (internationellt som nationellt), urbana och lokala bidrag. I denna rapport presenteras modellen tillsammans med en första studie av luftkvaliteten med avseende på PM10 (partiklar med en diameter mindre än 10 µm) inom ett par testkommuner, nämligen Vänersborg i Västergötlands län och Gnosjö i Jönköpings län.</p><p>Resultatet visade att det finns områden även i små kommuner där sämre luftkvalitet kan utgöra ett problem. Till största delen berodde detta på hög emission från fastigheter med äldre vedeldningspannor utan ackumulatortank.</p><p>I Vänersborg undersöktes luftkvaliteten med avseende på PM10 i stadsdelarna Vargön, Mariedal och centrum för år 2003. För hela kommunen gällde att övre utvärderingströskel (gränsvärde för vilka mätningar är obligatoriska), som för årsmedelvärdet PM10 är 14 μg/m3 luft, överskrids pga bakgrundsbidrag. Samtliga av de undersökta områdena uppvisade dock halter som är lägre än miljökvalitetsnormerna. Beräkningar i VEDAIR för Vargön, inom vilket vedeldningen är huvudsakliga källan till emissionen av PM10, visade att koncentrationen partiklar inom vissa områden var lika höga eller högre än områden runt de mest trafikerade vägarna i centrala Vänersborg (årsmedelvärde på ca 20 μg/m3). I centrum var dock föroreningarna mer utbredda. Allra högst halter PM10 erhölls vid beräkningar i Mariedal, till följd av utbredd vedeldning med äldre vedpannor, trafikerade vägar och ogynnsamma meteorologiska förutsättningar. Enligt detta kan mätning av partiklar inom området vara befogat. Tidsserier av totalhalten PM10 visade att högst halter erhölls på vintern i Vargön, till följd av större uppvärmningsbehov i kombination med lägre utomhustemperatur och mer stabil skiktning. Det lokala bidraget uppvisade en negativ korrelation mot temperaturen. I centrum var halterna dock högst på våren pga slitagepartiklar från dubbdäck samt vägdamm.</p><p>För Gnosjö undersöktes luftkvaliteten i tre potentiella problemområden; Gårö, centrala Gnosjö och Götarp. Beräkningar i VEDAIR för Gnosjö visade att trafikens bidrag var betydligt mindre, men vedeldning var vanligt förekommande. Samtidigt var årsmedelvärdet för det regionala bakgrundsbidraget ca 1 μg/m3 högre än i Vänersborg. Luftkvaliteten var generellt sett likvärdig den för Vänersborg, men inom stadsdelen Gårö fanns ett område där koncentrationen PM10 var mycket nära miljökvalitetsnormerna. Huvudkällan till emissionen var en enskild fastighet med stort energibehov som värmdes upp uteslutande med ved.</p><p>I studien gjordes även jämförelse av beräknade PM10-halter från VEDAIR med uppmätta värden i Gnosjö för perioden 3 november till 31 december 2003. Valideringen visade att VEDAIR gav något underskattade, men ändå hyggliga resultat. Tidigare valideringar har enbart utförts för Norrland, och de nya resultaten tyder på att VEDAIR även ger tillförlitliga beräkningar för södra Sverige.</p><p>Studien visade också att om en enskild fastighetsägare skulle byta ut en äldre vedeldningspanna mot en modern med ackumulatortank skulle årsmedelvärdet PM10 lokalt i fastighetens närområde kunna sjukna med uppåt 4 μg/m3, vilket är en minskning med 25%.</p>
|
4 |
Undersökning av luftkvaliteten vid småskalig biobränsleförbränning i två kommuner med modellsystemet VEDAIRAndersson, Stefan January 2007 (has links)
An Internet application, VEDAIR, for estimation of air quality in regions with small-scale combustion of bio fuel has been developed by Swedish Meteorological and Hydrological Institute with financing from Swedish Energy Agency and Swedish Environmental Protection Agency. The model contains user interface and a coupled model concept where concentrations of atmospheric pollutions are calculated for regional, urban and local contributions. In this report the model is described and a first study of air quality considering PM10 (particles with a diameter less than 10 µm) in two Swedish municipalities, Vänersborg and Gnosjö, is introduced. According to the result, there are areas with poor air quality even in smaller Swedish municipalities, mostly due to high emission from buildings with older wood heating furnace without hydraulic accumulator. In Vänersborg three areas were analysed in VEDAIR for the year 2003: Vargön, Mariedal and the downtown district. In the whole municipality the upper evaluation threshold for PM10, which is defined as 14 µg/m3 for annual average, was exceeded due to background contribution of particles. In all areas, however, the concentrations of PM10 were less than the environmental quality norms. In Vargön, where wood heating furnaces are commonly used, in some areas the concentration of particles was as big as or bigger than the downtown district (annual average of 20 µg/m3). However, in downtown the pollutants were more spread. Biggest concentrations of PM10 were estimated in Mariedal, due to emissions from older wood heating furnaces and streets, mostly in areas with unfavourable meteorological conditions. Measurements of PM10 in the area are therefore suggested. Biggest concentrations of PM10 were prevailed during winter, due to great heating need in combination with cooler air temperature and more stable stratification. The local contribution of PM10 was negative correlated with temperature. In the downtown district, however, the biggest concentrations of PM10 were obtained during spring due to usage of studded tyres. In Gnosjö the air quality considering PM10 was analysed in the areas Götarp, downtown and Gårö. Calculations in VEDAIR showed that the emissions from traffic were much less than wood heating furnace. The background annual average of PM10 in Gnosjö was 1 µg/m3 higher than Vänersborg. The air quality was quite equal as in Vänersborg, but there was an area in Gårö where the environmental quality norms considering PM10 almost were exceeded, this mostly due to emission from one building with high heating need. In this study a comparison between calculated concentrations of PM10 with measured concentrations in Gnosjö for the period 3 November to 31 December 2003 was also made. The validation showed that VEDAIR underestimated the concentrations, but the result was anyway reasonable. Before, validations have only been performed for the northern part of Sweden, and this study indicates that VEDAIR also estimates concentrations of PM10 sufficiently well in southern part of Sweden. The study also showed that if a house owner would replace an old wood heating furnace by a modern furnace with hydraulic accumulator, the annual average of the concentration of PM10 could decrease by 4 µg/m3 which is a reduction of 25%. / Ett internetverktyg, VEDAIR, för bedömning av luftkvalitet vid småskalig förbränning av biobränsle har utvecklats av SMHI med finansiering från bland andra Energimyndigheten och Naturvårdsverket. Modellen består av användargränssnitt och ett kopplat modellsystem där halterna av luftföroreningar beräknas för såväl regionala (internationellt som nationellt), urbana och lokala bidrag. I denna rapport presenteras modellen tillsammans med en första studie av luftkvaliteten med avseende på PM10 (partiklar med en diameter mindre än 10 µm) inom ett par testkommuner, nämligen Vänersborg i Västergötlands län och Gnosjö i Jönköpings län. Resultatet visade att det finns områden även i små kommuner där sämre luftkvalitet kan utgöra ett problem. Till största delen berodde detta på hög emission från fastigheter med äldre vedeldningspannor utan ackumulatortank. I Vänersborg undersöktes luftkvaliteten med avseende på PM10 i stadsdelarna Vargön, Mariedal och centrum för år 2003. För hela kommunen gällde att övre utvärderingströskel (gränsvärde för vilka mätningar är obligatoriska), som för årsmedelvärdet PM10 är 14 μg/m3 luft, överskrids pga bakgrundsbidrag. Samtliga av de undersökta områdena uppvisade dock halter som är lägre än miljökvalitetsnormerna. Beräkningar i VEDAIR för Vargön, inom vilket vedeldningen är huvudsakliga källan till emissionen av PM10, visade att koncentrationen partiklar inom vissa områden var lika höga eller högre än områden runt de mest trafikerade vägarna i centrala Vänersborg (årsmedelvärde på ca 20 μg/m3). I centrum var dock föroreningarna mer utbredda. Allra högst halter PM10 erhölls vid beräkningar i Mariedal, till följd av utbredd vedeldning med äldre vedpannor, trafikerade vägar och ogynnsamma meteorologiska förutsättningar. Enligt detta kan mätning av partiklar inom området vara befogat. Tidsserier av totalhalten PM10 visade att högst halter erhölls på vintern i Vargön, till följd av större uppvärmningsbehov i kombination med lägre utomhustemperatur och mer stabil skiktning. Det lokala bidraget uppvisade en negativ korrelation mot temperaturen. I centrum var halterna dock högst på våren pga slitagepartiklar från dubbdäck samt vägdamm. För Gnosjö undersöktes luftkvaliteten i tre potentiella problemområden; Gårö, centrala Gnosjö och Götarp. Beräkningar i VEDAIR för Gnosjö visade att trafikens bidrag var betydligt mindre, men vedeldning var vanligt förekommande. Samtidigt var årsmedelvärdet för det regionala bakgrundsbidraget ca 1 μg/m3 högre än i Vänersborg. Luftkvaliteten var generellt sett likvärdig den för Vänersborg, men inom stadsdelen Gårö fanns ett område där koncentrationen PM10 var mycket nära miljökvalitetsnormerna. Huvudkällan till emissionen var en enskild fastighet med stort energibehov som värmdes upp uteslutande med ved. I studien gjordes även jämförelse av beräknade PM10-halter från VEDAIR med uppmätta värden i Gnosjö för perioden 3 november till 31 december 2003. Valideringen visade att VEDAIR gav något underskattade, men ändå hyggliga resultat. Tidigare valideringar har enbart utförts för Norrland, och de nya resultaten tyder på att VEDAIR även ger tillförlitliga beräkningar för södra Sverige. Studien visade också att om en enskild fastighetsägare skulle byta ut en äldre vedeldningspanna mot en modern med ackumulatortank skulle årsmedelvärdet PM10 lokalt i fastighetens närområde kunna sjukna med uppåt 4 μg/m3, vilket är en minskning med 25%.
|
5 |
The Attractive Workplace : Are the Site Offices Meeting the Employees´Needs? / Den attraktiva arbetsplatsen : Möter platskontoren de anställdas behov?Haegerstrand, Anna, Knutsson, Emelia January 2019 (has links)
Previous research have shown a possible relationship between the indoor work environmentand the impact it has on the employees’ performance. Different factors can affect theperformance; physical parameters, such as ventilation and air quality, noise levels, thermalclimate, lighting and access to daylight, as well as the level of flexibility of the work, furnitureetc. Therefore, this study aims to investigate the quality of the indoor work environment at siteoffices within Company AB in Sweden. Further, how the physical and the psychologicalenvironment play an important role regarding the attractiveness of the workspace. The studywill only focus on four physical parameters affecting the physical functionality of an office; airquality, noise, temperature and lighting. The following research questions were asked: 1) Whatdifferent types of site offices can be identified in Sweden and what are the commonly usedoffice layouts? 2) How well does the actual indoor work environment at site offices align withthe restrictions by the Swedish Work Environment Authority? 3) How is the indoorenvironment of the site offices perceived by the people utilizing the workspace? 4) Which arethe most important parts to look at to improve the attractiveness of the site offices at CompanyAB? The study is both qualitative and quantitative including measurements, interviews,meetings, and a questionnaire as the main sources of information used to answer the researchquestions.According to the results, the two most commonly used site offices are construction trailers andrented premises. The visited offices had varied layouts since they are designed to fit the needsof the specific project organizations. Out of the four parameters, noise was the only one thatentirely fulfilled the requirements in the six site offices visited.The employees perceived the physical parameters in the site offices differently. The air qualitywas generally perceived to be sufficient in the office spaces but quite bad in the meeting rooms.Multiple employees thought noise was one of the most problematic parameters and it wasshown to possibly depend on work role or task. Employees expressed the need of a versatileoffice layout, with both open office areas and smaller secluded rooms combined, which couldincrease their concentration level and decrease disturbance. Another problematic parameterwas the temperature and generally, the need was to stabilize it throughout the year. Regardingthe lighting, many expressed the desire to be able to adjust it on their own.People perceive things differently which is why a more varied and flexible office might fulfillmore people’s needs. If these needs are fulfilled, it could improve not only the physical workenvironment but also the psychological work environment and therefore increase theattractiveness and job satisfaction of the employees. / Tidigare forskning har visat en möjlig koppling mellan inomhusklimat och dess påverkan påden anställdas prestation. Olika faktorer kan påverka prestationen; fysiska parametrar; såsomventilation och luftkvalitet, ljudnivå, termiskt klimat, ljus och tillgång till dagsljus samt nivånav flexibilitet på jobbet, möbler och andra faktorer. Därför syftar denna studie till att undersökakvalitén av arbetsmiljön inomhus på platskontor hos Company AB i Sverige. Vidare, hur denfysiska och psykiska miljön spelar en stor roll gällande hur attraktiv en arbetsplats är. Dennastudie kommer bara fokusera på fyra fysiska parametrar som påverkar den fysiskafunktionaliteten av ett kontor; luftkvalitet, ljud, temperatur och ljus. Följande forskningsfrågorhar ställts: 1) Vilka olika typer av platskontor kan identifieras i Sverige och vilka olikautformningar används vanligast? 2) Hur väl uppfyller den faktiska inomhusmiljön påplatskontoren kraven från Arbetsmiljöverket? 3) Hur upplevs inomhusmiljön på platskontorenav människorna som jobbar i dem? 4) Vilka är de viktigaste aspekterna för att ökaattraktiviteten av platskontoren på Company AB? Studien är både kvalitativ och kvantitativoch inkluderar både mätningar, intervjuer, möten och en enkät som de främstainformationskällorna för att svara på forskningsfrågorna.Resultaten visar på att de vanligaste platskontoren är byggbodar och inhyrda lokaler. Debesökta kontoren hade olika uppbyggnad eftersom de var utformade för att passa de specifikaprojektorganisationerna. Utav de fyra parametrarna var ljudet det enda som uppfyllde kraven ide sex besökta platskontoren.De anställda upplevde de fysiska parametrarna på olika sätt. Luftkvaliteten upplevdes generelltsom tillräcklig bland kontorsplatserna men ganska dålig i mötesrummen. Flera anställda tyckteatt ljudet var en av de mest problematiska parametrarna och det visade sig möjligtvis bero påarbetsroll eller uppgift. De anställda uttryckte ett behov av en varierad utformning av kontorenmed en kombination av både öppna kontorslandskap och mindre avskilda rum vilket skullekunna öka koncentrationsförmågan och minska störande ljud. En annan problematiskparameter var temperaturen och generellt var behovet att få en mer stabil temperatur över året.Vad gäller ljussättningen så uttryckte många att de ville kunna reglera den själva.Människor upplever saker olika vilket gör att ett mer varierat och flexibelt kontor kan uppfyllafler människors behov. Om dessa behov uppfylls kan detta förbättra inte bara den fysiskaarbetsmiljön utan också den psykiska arbetsmiljön och kan därigenom öka attraktiviteten samtarbetsnöjdheten hos de anställda.
|
Page generated in 0.0275 seconds