• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da integridade de luvas cirúrgicas em um hospital oncológico do interior paulista / Evaluation of the integrity of surgical gloves in an oncological hospital in the state of São Paulo

Luize, Paula Batista 11 May 2018 (has links)
Introdução: a utilização de luvas cirúrgicas estéreis é uma estratégia fundamental para a prevenção de infecção do sítio cirúrgico e para a proteção da equipe cirúrgica. Entretanto é comum a ocorrência de perfurações de luvas durante os procedimentos cirúrgicos as quais, em sua maioria, não são percebidas pelos profissionais. Objetivos: testar a associação entre a ocorrência de perfuração de luvas cirúrgicas e o número de cirurgiões em campo, o tempo de duração da cirurgia, o tipo de cirurgia, o tipo de abordagem cirúrgica e a especialidade cirúrgica. Materiais e Métodos: trata-se de um estudo de corte transversal realizado num hospital especializado em oncologia do interior paulista. A população do estudo foi composta por 3.966 luvas utilizadas em 359 cirurgias realizadas no referido hospital, no período de 01 de janeiro a 28 de fevereiro de 2018. A avaliação da integridade das luvas cirúrgicas foi realizada por meio de análise visual e da insuflação de líquido, conforme a norma EN 455-1. Os dados foram analisados por meio de estatística descritiva e pela técnica de regressão logística multivariada, utilizando-se o programa estatístico IBM SPSS Statistics versão 21. Resultados: Das 359 cirurgias analisadas, 145 (40,4%) cirurgias apresentaram luvas perfuradas. Das 3.966 luvas coletadas, 254 (6,4%) apresentaram perfuração. Do total de perfurações identificadas, 163 (64,2%) ocorreram na mão esquerda, atingiram o dedo indicador 94 (37,0%). As varáveis associadas à perfuração de luvas identificadas no modelo final foram cirurgias com tempo de duração acima de 120 minutos (OR: 3,06; IC 95%: 1,52 - 6,14) e cirurgias realizadas pelas especialidades da Ortopedia (OR: 4,40; IC95%: 2,36 - 8,20), do Tórax (OR: 3,28; IC95%: 1,75 - 6,17), da Urologia (OR: 2,97; IC95%: 1,53 - 5,76) e do Digestivo Baixo (OR: 2,35; IC95%: 1,22 - 4,54). Ressalta-se que as cirurgias realizadas por vídeo se constituíram num fator de proteção (OR: 0,35; IC95%: 0,22 - 0,56). Conclusão: o presente estudo confirmou a associação entre a perfuração de luvas e tempo de duração da cirurgia acima de 120 minutos e especialidades cirúrgica, além disso, as cirurgias realizadas por vídeo se constituíram como um fator de proteção. Acredita-se que os resultados obtidos poderão subsidiar a proposição de medidas de prevenção e consequentemente contribuir para a segurança dos pacientes e dos profissionais da área da saúde / Introduction: the use of sterile surgical gloves is a fundamental strategy for the prevention of infection of the surgical site and for the protection of the surgical team. However, perforated gloves are common during surgical procedures which, for the most part, are not perceived by professionals. Objective: to test the association between the occurrence of surgical glove perforation and the number of surgeons in the surgery, the duration of the surgery, the type of surgery, the type of surgical approach and the surgical specialty. Materials and Methods: this is a crosssectional study conducted at a specialized hospital in oncology in the state of São Paulo. The study population consisted of 3.966 gloves used in 359 surgeries performed at the referred hospital, from January 1 to February 28, 2018. The evaluation of surgical glove integrity was performed through visual analysis and fluid insufflation, in accordance with EN 455-1. Data were analyzed using descriptive statistics and the multivariate logistic regression technique using the IBM SPSS Statistics version 21 statistical program. Results: of the 359 surgeries analyzed, 145 (40,4%) surgeries had perforated gloves. Of the 3.966 gloves collected, 254 (6,4%) presented perforation. Of the total number of perforations identified, 163 (64,2%) occurred in the left hand, reaching the index finger 94 (37,0%). The variables associated with the perforation of gloves identified in the final model were surgeries with duration time over 120 minutes (OR: 3,06; 95% CI: 1,52 - 6,14) and surgeries performed by Orthopedics specialties (OR: 4,40; 95% CI: 2,36 - 8,20), Thorax (OR: 3.28; 95% CI:1.75 - 6.17), Urology (OR: 2,97; 95% CI: 1,53 - 5,76) and the Low Digestive (OR: 2.35; 95% CI: 1,22 - 4,54). It should be emphasized that the surgeries performed by video were constituted as a protection factor (OR: 0,35; 95% CI: 0,22 - 0,56). Conclusion: the present study confirmed the association between the perforation of gloves and the duration of surgery over 120 minutes and surgical specialties, besides that the surgeries performed by video were constituted as a protection factor. It is believed that the results obtained may support the proposal of preventive measures and consequently contribute to the safety of patients and health professionals
2

Tecnologia educacional como estratégia para o uso de luvas pelos profissionais de enfermagem visando a precaução de contato

Padilha, Jovíria Márcia Ferreira de Oliveira January 2014 (has links)
Submitted by Fabiana Gonçalves Pinto (benf@ndc.uff.br) on 2017-03-16T17:11:05Z No. of bitstreams: 1 Joviria Marcia Ferreira de Oliveira Padilha.pdf: 1968331 bytes, checksum: b469b4bab4f213247f9b3817b0d25da6 (MD5) / Made available in DSpace on 2017-03-16T17:11:05Z (GMT). No. of bitstreams: 1 Joviria Marcia Ferreira de Oliveira Padilha.pdf: 1968331 bytes, checksum: b469b4bab4f213247f9b3817b0d25da6 (MD5) Previous issue date: 2014 / Mestrado Profissional em Enfermagem Assistencial / A infecção relacionada à assistência à saúde (IRAS) é considerada um problema de saúde pública em esfera mundial. Assim, torna-se preponderante a intervenção nos cuidados e prevenção destes agravos. Diante desta prerrogativa, o estudo tem como objeto: a precaução de contato a partir de uma tecnologia educacional (TE), visando o uso de luvas pelos profissionais de enfermagem. Objetivo geral: propor uma TE em forma de mídia audiovisual visando à adequação e/ou adesão dos profissionais de enfermagem às medidas de precaução de contato, foco em luvas. Objetivos específicos: identificar os fatores que interferem na adesão e/ou adequação às medidas de precaução de contato na utilização das luvas de procedimentos e estéreis pela equipe de enfermagem; elaborar uma TE visando adesão e adequação dos profissionais de enfermagem às medidas de precaução de contato, foco em luvas, a partir das falas dos profissionais; validar uma TE em forma de mídia audiovisual, visando adequação e adesão às medidas de precaução de contato com foco nas luvas. Metodologia: pesquisa de abordagem quantiqualitativa do tipo metodológica. O cenário da pesquisa foi o Hospital Universitário Antônio Pedro da Universidade Federal Fluminense. Os participantes foram 66 profissionais distribuídos em quatro etapas do estudo. Para elaboração e validação da TE, a coleta de dados ocorreu nas quatro etapas. A 1ª etapa: realizaram-se entrevistas e a análise temática segundo Bardin. Critérios de inclusão: profissionais de enfermagem da clínica cirúrgica, diaristas ou plantonistas, estatutários ou contratados, em exercício. Critérios de exclusão: profissionais em férias e/ou licenças médicas; 2ª etapa: elaboração da TE a partir das categorias que emergiram da primeira etapa; 3ª etapa: validação de TE. Nesta etapa foram utilizados instrumentos de validação, escala Likert, respondidos por juízes especialistas e público alvo. Os itens do instrumento analisados receberam diferentes valorações em cada bloco, sendo considerados válidos os itens que obtiveram concordância maior ou igual a 70% pelos avaliadores desta etapa; 4ª etapa: adequação da TE a partir da avaliação dos profissionais. Resultados: a partir da fala dos profissionais emergiram três categorias, a saber: Conhecimento geral acerca do uso de luvas; A utilização das luvas na prática de enfermagem e suas implicações; Avaliação do material das luvas. A partir destas categorias, foi elaborada uma TE em forma de mídia audiovisual, cuja validação dos resultados atingiu índice de concordância superior a 80%. Conclui-se que a elaboração e aplicação de TE voltadas para o ensino e aprendizagem do profissional são primordiais para a segurança do paciente, do profissional e do ambiente, minimizando os riscos de infecções cruzadas / The Infection related to health care (IRAS) is considered a public health problem in the whole world. Thus, a major intervention in the care and prevention of these diseases is of utmost importance. In the view of this prerogative, the current object of this study is: the contact precautions as an educational technology (ET), to the use of gloves by nursing professionals. Overall objective: to propose an ET in audiovisual media format in order to improve adhesion/adjustments of nursing professionals to contact precautions, focusing in the use of gloves. Specific objectives: to identify the factors that influence in adherence and/or adequacy for contact precautions with the use of procedure and sterile gloves by nursing staff; to develop an ET aiming at adherence and adequacy of nursing professionals to contact precautions, focusing in the use of gloves, from the speeches of professionals; to validate an ET in audiovisual media format, aiming to adequacy and adherence to contact precautions focused in the use of gloves. Methodology: Research with quantiqualitative approach of methodological type. The research scenario was the Antônio Pedro University Hospital, Fluminense Federal University. Participants were 66 professionals divided into four stages of the study. For development and validation of ET, data collection occurred in all the four stages. 1st stage: interviews and Bardin’s thematic analysis were conducted. Inclusion criteria: nurses of surgical clinic department, resident or day labor, statutory- or private-contracted, and currently active. Exclusion criteria: professionals on vacation and / or in sick leave; 2nd stage: preparation of the ET based the categories that emerged from the first stage; 3rd stage: ET validation. At this stage the Likert scale and validation instruments were used, answered by expert judges and target audience. The instrument items analyzed received different valuations in each block, being considered as valid the items with agreement levels greater than or equal to 70% by the evaluators of this stage; 4th stage: adequacy of ET by the evaluation of professionals. Results: from the speech of professionals emerged three categories, namely: General knowledge about the use of gloves; the use of gloves in nursing practice and its implications; analysis of the glove material. From these categories, an ET was prepared in audiovisual media format, and the validation of its results reached an agreement index higher than 80%. It is concluded that the development and application of an ET facing professional education and learning are essential for the safety of patients, professionals and the environment, minimizing the risk of cross-infection
3

Avaliação das propriedades fisico-químicas das luvas de policloreto de Vinila (PVC) sob regime de vigilância sanitária. / Evaluation of the physico-chemical properties of polyvinyl chloride gloves (PVC) under health surveillance.

MARTINS, Priscilla Consigliero de Rezende. 17 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-17T12:40:12Z No. of bitstreams: 1 PRISCILLA CONSIGLIERO DE REZENDE MARTINS - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1527771 bytes, checksum: cc67203373e93ed35f44365878e7d5cb (MD5) / Made available in DSpace on 2018-04-17T12:40:12Z (GMT). No. of bitstreams: 1 PRISCILLA CONSIGLIERO DE REZENDE MARTINS - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1527771 bytes, checksum: cc67203373e93ed35f44365878e7d5cb (MD5) Previous issue date: 2014-10-28 / A partir de 1980, em virtude do surgimento da AIDS/HIV, o Centers for Disease Control and Prevention (CDC) preconizou as “Precauções Universais”, e então as luvas passaram a ser utilizadas amplamente nos serviços de saúde. Popularizado o uso das luvas, começaram a surgir os primeiros relatos de reações alérgicas induzidas pelo látex. A partir de então, as empresas desenvolveram substitutos sintéticos para o látex, tais como PVC. Em 2011, foi publicada a Resolução RDC nº 55 que estabeleceu os requisitos mínimos de identidade e qualidade para as luvas cirúrgicas e luvas para procedimentos não cirúrgicos de borracha natural, de borracha sintética, de mistura de borrachas natural e sintética e de policloreto de vinila. Desta forma, este trabalho propôs a caracterização e a avaliação das luvas para procedimentos não cirúrgicos produzidas de policloreto de vinila, no intuito de verificar se as luvas estão em conformidade em relação à Norma - ABNT NBR ISO 11193-2. Para isso foram avaliadas 3 diferentes marcas comerciais de luvas para procedimentos não cirúrgicos de PVC cadastradas na ANVISA, sendo caracterizadas por DRX, FTIR, MEV, EDS, molhabilidade, e avaliadas quanto às dimensões, à impermeabilidade, e à força de ruptura e alongamento na ruptura conforme metodologia da norma. No FTIR observaram-se quantidades de grupamentos químicos semelhantes em todas as amostras analisadas. O MEV demonstrou a morfologia da superfície lisa e plana das Luvas D e E, enquanto a Luva S apresentou superfície texturizada e uniforme. Evidenciouse que as amostras das luvas de policloreto de vinila ensaiadas não atenderam aos requisitos mecânicos estabelecidos na norma vigente, principalmente no que diz respeito ao alongamento mínimo da ruptura de 350%. Diante do resultado, sugere-se o programa de monitoramento e avaliação da conformidade com um maior número de amostras de luvas de policloreto de vinila, assim como a posterior avaliação da Resolução RDC 55, de 4 de novembro de 2011, para avaliar a necessidade da inclusão das luvas de policloreto de vinila no escopo de certificação compulsória. / During the mid-1980´s, due to the emergence of AIDS, the Centers for Disease Control and Prevention (CDC) introduction the "Universal Precautions" and gloves began to be widely used in health services. The use of gloves was popularize in medical and surgical procedures, and reports of allergic reactions induced by latex began to emerge. Since then, companies have developed synthetic substitutes for latex, such as PVC. In 2011, was published the Resolution RDC nº 55 which established the minimum requirements of identity and quality for surgical and exam gloves made of natural rubber, synthetic rubber, a mixture of natural and synthetic rubbers and polyvinyl chloride. Thus, this study proposes the characterization and evaluation of exam vinvyl gloves, in order to check if the gloves meet the requirements of the standard ABNT NBR ISO 11193-2. Three different brands of regularized exam gloves at ANVISA were evaluated, being characterized by XRD, FTIR, SEM, EDS, Wetting Test, as well as evaluated the size, impermeability, and tensile properties according to the standard methodology. It was observed similar quantities of chemical groups in all samples analyzed by FTIR. The SEM morphology showed a smooth flat surface of the gloves D and E, while the S glove presented textured and uniform surface. It was shown that samples of vinyl gloves tested did not meet the standard´s mechanical requirements, especially the breaking elongation´s requirement of 350%. A conformity assessment with a larger sample of vinyl gloves it is suggested, as well as a further review of the Resolution RDC 55/2011 to assess the need for inclusion of vinyl gloves in the scope of mandatory certification.
4

Identificação dos fatores associados à sensibilização e alergia ao látex em pacientes com defeito de fechamento do tubo neural / Identification of factors associated with latex sensitization and allergy in patients with defects of neural tube closure

Garro, Laila Sabino 23 May 2013 (has links)
A alergia ao látex representa um importante problema de saúde em pacientes denominados de risco e está relacionada com a ocorrência de diversas manifestações clínicas, inclusive reações potencialmente fatais. O estudo de fatores associados à sensibilização e alergia ao látex é fundamental para o estabelecimento de medidas eficazes quanto à prevenção, tratamento e conhecimento do prognóstico. O principal grupo de risco para a alergia ao látex são os pacientes com defeito de fechamento do tubo neural. O estudo atual teve como objetivo principal identificar fatores clínicos e sorológicos associados à sensibilização e alergia ao látex em pacientes com defeito de fechamento do tubo neural. A pesquisa também analisou concentrações de corte de IgE específica sérica para látex e alérgenos do látex que pudessem identificar pacientes sensibilizados e alérgicos ao látex e avaliou o comportamento da IgG4 específica para látex como fator de proteção associado à ausência de sintomas. Com o intuito de responder estas perguntas, foi realizado um estudo transversal tipo coorte retrospectiva com 400 pacientes com defeito de fechamento do tubo neural, entre 0 e 18 anos, que estavam em seguimento na Associação de Assistência à Criança Deficiente - AACD. Após responderem a questionário específico, os pacientes foram submetidos à coleta de sangue periférico para a detecção dos níveis séricos de IgE total, IgE e IgG4 séricas específicas para látex, IgE sérica específica para rHevb1, 3, 5, 6.01, 6.02, 8, 9 e 11, Dermatophagoides pteronyssinus, Blomia tropicalis, abacate, banana, castanha, mamão, batata, através da metodologia ImmunoCap®. De acordo com a história clínica e o valor da IgE sérica específica para látex, os pacientes foram classificados em quatro grupos: sensibilizados asintomáticos ao látex, alérgicos ao látex, sintomáticos sem sensibilização e controle negativo. A prevalência total de sensibilização ao látex nesta amostra de pacientes foi de 33,2%, sendo 12,2% alérgicos e 21,0% sensibilizados assintomáticos ao látex. Os sintomas cutâneos foram a manifestação clínica mais comum de alergia ao látex (79,6%), sendo a urticária de contato a mais prevalente (67,3%). Houve episódios de anafilaxia associados à exposição ao látex em 21 pacientes (5,2%). Níveis de IgE sérica específica para látex de 0,77 kUA/L foram capazes de diferenciar com boa acurácia os pacientes alérgicos dos demais. Na comparação entre os grupos controle negativo e alérgico, sensibilizado e alérgico, houve diferença entre as variáveis clínicas, cirúrgicas e laboratoriais que estiveram associadas à alergia ao latex. A razão entre IgG4/IgE séricas específicas para látex foi estatisticamente maior no grupo controle negativo. A análise multivariada mostrou na comparação entre o grupo controle negativo e alérgico que a presença de IgE sérica específica para rHevb1 e IgE rHevb5 estão associadas com alergia. Na comparação entre o grupo sensibilizado e alérgico, houve associação de alergia com a presença de IgE sérica específica para rHevb5 e com escore clínico >= 40%. Por outro lado, a IgG4 sérica específica para látex esteve associada à ausência de sintomas no grupo sensibilizado / Latex allergy is an important health problem in patients at risk groups and it is associated with the occurrence of many clinical manifestations, including potentially fatal reactions. The study of factors associated with latex sensitization and allergy is crucial to establish effective measures of prevention, treatment and prognostic. The main risk group for latex allergy is patients with neural tube defects. The objective of this study was to identify the clinical and serologic factors associated with sensitization and allergy to latex. Levels of specific IgE to latex and latex allergens associated with allergy, as well as levels of specific IgG4 associated with clinical tolerance, were established, and its accuracy and cutoff values were calculated. The profile of clinical manifestations, including anaphylaxis, was also characterized. This study was a retrospective cross-sectional cohort of 400 patients with neural tube defects, between 0 and 18 years, who were being followed at the Association for Assistance of Disabled Children - AACD. After answering a specific questionnaire, patients were submitted to blood draw for the detection of total IgE, specific IgG4 to latex, and specific IgE to latex, rHevb (1, 3, 5, 6.01, 6.02, 8, 9, 11), Dermatophagoides pteronyssinus, Blomia tropicalis, avocado, banana, cashew, papaya, and potato, by ImmunoCAP ® methodology. According to the history and value of specific IgE to latex, patients were classified into four groups: sensitized asymptomatic patients, allergic patients, symptomatic patients and negative control. The overall prevalence of latex sensitization in this sample of patients was 33.2%, with 12.2% of allergic and 21.0% of sensitized patients. The skin symptoms were the most common clinical manifestation of latex allergy (79.6%), and contact urticaria was the most prevalent (67.3%). Anaphylaxis after latex exposure was observed in 21 patients (5.2%). Levels of specific IgE to latex of 0.77 kUA/L were able to differentiate allergic patients, with good accuracy. Comparing the negative control and allergic groups, the sensitized and allergic groups they had differents clinical, surgical and laboratory factors associated with allergy to latex. The ratio serum specific IgG4/IgE to latex was statistically higher in the negative control group. Multivariate analysis showed, in the comparison between the negative control and allergic groups, that the presence of serum specific IgE to rHevb1 and rHevb5 were associated with allergy. Comparing the sensitized and allergy groups, allergy was associated with the presence of serum specific IgE to rHevb5 and clinical score >= 40%. Moreover, serum specific IgG4 to latex was associated with lack of symptoms in the sensitized group.
5

Identificação dos fatores associados à sensibilização e alergia ao látex em pacientes com defeito de fechamento do tubo neural / Identification of factors associated with latex sensitization and allergy in patients with defects of neural tube closure

Laila Sabino Garro 23 May 2013 (has links)
A alergia ao látex representa um importante problema de saúde em pacientes denominados de risco e está relacionada com a ocorrência de diversas manifestações clínicas, inclusive reações potencialmente fatais. O estudo de fatores associados à sensibilização e alergia ao látex é fundamental para o estabelecimento de medidas eficazes quanto à prevenção, tratamento e conhecimento do prognóstico. O principal grupo de risco para a alergia ao látex são os pacientes com defeito de fechamento do tubo neural. O estudo atual teve como objetivo principal identificar fatores clínicos e sorológicos associados à sensibilização e alergia ao látex em pacientes com defeito de fechamento do tubo neural. A pesquisa também analisou concentrações de corte de IgE específica sérica para látex e alérgenos do látex que pudessem identificar pacientes sensibilizados e alérgicos ao látex e avaliou o comportamento da IgG4 específica para látex como fator de proteção associado à ausência de sintomas. Com o intuito de responder estas perguntas, foi realizado um estudo transversal tipo coorte retrospectiva com 400 pacientes com defeito de fechamento do tubo neural, entre 0 e 18 anos, que estavam em seguimento na Associação de Assistência à Criança Deficiente - AACD. Após responderem a questionário específico, os pacientes foram submetidos à coleta de sangue periférico para a detecção dos níveis séricos de IgE total, IgE e IgG4 séricas específicas para látex, IgE sérica específica para rHevb1, 3, 5, 6.01, 6.02, 8, 9 e 11, Dermatophagoides pteronyssinus, Blomia tropicalis, abacate, banana, castanha, mamão, batata, através da metodologia ImmunoCap®. De acordo com a história clínica e o valor da IgE sérica específica para látex, os pacientes foram classificados em quatro grupos: sensibilizados asintomáticos ao látex, alérgicos ao látex, sintomáticos sem sensibilização e controle negativo. A prevalência total de sensibilização ao látex nesta amostra de pacientes foi de 33,2%, sendo 12,2% alérgicos e 21,0% sensibilizados assintomáticos ao látex. Os sintomas cutâneos foram a manifestação clínica mais comum de alergia ao látex (79,6%), sendo a urticária de contato a mais prevalente (67,3%). Houve episódios de anafilaxia associados à exposição ao látex em 21 pacientes (5,2%). Níveis de IgE sérica específica para látex de 0,77 kUA/L foram capazes de diferenciar com boa acurácia os pacientes alérgicos dos demais. Na comparação entre os grupos controle negativo e alérgico, sensibilizado e alérgico, houve diferença entre as variáveis clínicas, cirúrgicas e laboratoriais que estiveram associadas à alergia ao latex. A razão entre IgG4/IgE séricas específicas para látex foi estatisticamente maior no grupo controle negativo. A análise multivariada mostrou na comparação entre o grupo controle negativo e alérgico que a presença de IgE sérica específica para rHevb1 e IgE rHevb5 estão associadas com alergia. Na comparação entre o grupo sensibilizado e alérgico, houve associação de alergia com a presença de IgE sérica específica para rHevb5 e com escore clínico >= 40%. Por outro lado, a IgG4 sérica específica para látex esteve associada à ausência de sintomas no grupo sensibilizado / Latex allergy is an important health problem in patients at risk groups and it is associated with the occurrence of many clinical manifestations, including potentially fatal reactions. The study of factors associated with latex sensitization and allergy is crucial to establish effective measures of prevention, treatment and prognostic. The main risk group for latex allergy is patients with neural tube defects. The objective of this study was to identify the clinical and serologic factors associated with sensitization and allergy to latex. Levels of specific IgE to latex and latex allergens associated with allergy, as well as levels of specific IgG4 associated with clinical tolerance, were established, and its accuracy and cutoff values were calculated. The profile of clinical manifestations, including anaphylaxis, was also characterized. This study was a retrospective cross-sectional cohort of 400 patients with neural tube defects, between 0 and 18 years, who were being followed at the Association for Assistance of Disabled Children - AACD. After answering a specific questionnaire, patients were submitted to blood draw for the detection of total IgE, specific IgG4 to latex, and specific IgE to latex, rHevb (1, 3, 5, 6.01, 6.02, 8, 9, 11), Dermatophagoides pteronyssinus, Blomia tropicalis, avocado, banana, cashew, papaya, and potato, by ImmunoCAP ® methodology. According to the history and value of specific IgE to latex, patients were classified into four groups: sensitized asymptomatic patients, allergic patients, symptomatic patients and negative control. The overall prevalence of latex sensitization in this sample of patients was 33.2%, with 12.2% of allergic and 21.0% of sensitized patients. The skin symptoms were the most common clinical manifestation of latex allergy (79.6%), and contact urticaria was the most prevalent (67.3%). Anaphylaxis after latex exposure was observed in 21 patients (5.2%). Levels of specific IgE to latex of 0.77 kUA/L were able to differentiate allergic patients, with good accuracy. Comparing the negative control and allergic groups, the sensitized and allergic groups they had differents clinical, surgical and laboratory factors associated with allergy to latex. The ratio serum specific IgG4/IgE to latex was statistically higher in the negative control group. Multivariate analysis showed, in the comparison between the negative control and allergic groups, that the presence of serum specific IgE to rHevb1 and rHevb5 were associated with allergy. Comparing the sensitized and allergy groups, allergy was associated with the presence of serum specific IgE to rHevb5 and clinical score >= 40%. Moreover, serum specific IgG4 to latex was associated with lack of symptoms in the sensitized group.

Page generated in 0.834 seconds