Spelling suggestions: "subject:"materiais biomédicas"" "subject:"materiais biomédico""
61 |
Reparo osseo inserção de parafusos de aço inoxidavel, utilizados em fixação interna rigida. Estudo histologico em coelhosLiza, Ralf Gobbo 12 September 1996 (has links)
Orientador: Luiz Augusto Passeri / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-21T20:10:23Z (GMT). No. of bitstreams: 1
Liza_RalfGobbo_M.pdf: 1968980 bytes, checksum: 78cd176164433aaaa5dcc19965fb254b (MD5)
Previous issue date: 1996 / Resumo: Este estudo avaliou histologicamente, em tíbia de coelho, a sequência de eventos que ocorreram no tecido ósseo após a inserção de parafusos de aço inoxidável utilizados em fixação interna rígida. Oito coelhos adultos receberam cada um, quatro parafusos fornecidos por fabricantes diferentes. Os animais foram sacrificados após 1, 2, 3 e 4 semanas.A análise dos espécimes sob microscopia óptica comum revelou que todos os implantes foram bem tolerados pelo tecido ósseo adjacente, produzindo pouca reação inflamatória e permitindo a neoformação óssea / Abstract: This study evaluated the histological sequence of events occurred in the tíbia of rabbits after the implantatíon of stainless steel screws used in internal rigid fixation. Eight adult rabbits received each one, four brands of screws. Each screw provided by a different furnisher. The animaIs were killed after 1, 2, 3 and 4 weeks. Light microscopy of the specimens revealed that all the implants were well tolerated by the adjacent tissues, with a low degree of infla,mmatory reaction and allowing the bone neoformation / Mestrado / Cirurgia Buco-Maxilo-Facial / Mestre em Clínica Odontológica
|
62 |
Avaliação histologica em tibia de coelhos de parafusos de titanio utilizados em fixação interna rigidaIlg, Jan Peter 25 November 1996 (has links)
Orientador: Luis Augusto Passeri / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-21T23:22:56Z (GMT). No. of bitstreams: 1
Ilg_JanPeter_M.pdf: 3997698 bytes, checksum: dd671ae09848b711c5c21845b4820293 (MD5)
Previous issue date: 1996 / Resumo: A fixação interna de fraturas ou osteotomias através de placas ou parafusos veio diminuiro tempo de fixação intermaxilare aumentar a estabilidade destes procedimentos. Para que o material de síntese possa permanecer nos tecidos, o mesmo deve ser inerte, sem causar reações de corpo estranho. Para testar a biocompatibilidade de 4 marcas de parafusos de titânio para fixação interna rígida, foram usados 8 coelhos, dividídos em 4 grupos iguais. Em uma tíbia de cada coelho foram implantados 4 parafusos, sendo 1 de cada marca. Os animais foram sacrificados nos intervalos de 1, 2, 3 e 4 semanas. Após descalcificação da peça, os parafusos foram retirados e os cortes histológicos feitos no sentido do longo eixo do parafuso. Na primeira semana, houve discreta reação inflamatória na região da cabeça do parafuso para todas as marcas, e nos 3 intervalos seguintes não foi verificada reação inflamatória nesta área. Ao final da quarta semana havia tecido osteóide junto à cabeça de todos parafusos. No osso cortical foi verificado necrose em maior e menor grau nas 3 primeiras semanas, não relacionadas com as marcas dos parafusos. O osso esponjoso mostrou hemorragia medular em todos os grupos na primeira semana, sendo subsequentemente substituido por tecido conjuntivo fibroso nos intervalos seguintes. Na última semana houve proliferação de tecido osteóide na maioria dos grupos. Nos parafusos de uma das marcas verificou-se que a camada externa do metal soltava resíduos metálicos. Analisando-se os resultados, conclui-se que: não houve diferença entre as diferentes marcas de parafusos, sendo que todas apresentavam boa biocompatibilidade. A necrose verificada no osso cortical foi possivelmente devido ao trauma da perfuração para inserção dos parafusos / Abstract: Internal fixation of uactures or osteotomies with plates and screws diminishes intennaxillary fixation time and also increases the stability of these procedures. In order to remain in the tissues, the material must be inert, without causing foreign body reactions. To test the biocompatibility of 4 brands of titanium screws for rigid internal fixation, 8 rabbits were used, divided in 4 equal goups. Each rabbit received 1 screw of each brand placed in the same tibia. The animals were killed at 1, 2, 3 and 4 weeks intervals. After decalcification, the screws were removed uom the bone and histological sections were made parallel to the insertion axis of the
screws. At the first week, there was a slight inflamatory reaction close to the screw head on all brands, but on the 3 next intervals no
inflamation could be seen. At the end of the 4th week, osteoid was present close to the screw head on all screws. The cortical bone
showed necrosis of different intensity on the first 3 weeks, not related to the brand of the screws. Blood was seen in medullary bone on the first week on every screw, being substituted by connective tissue during the next 3 weeks. On the last week, osteoid was seen on the threads on almost all screws. Screws from one brand had an outer layer that loosened and left small metallic pieces in the tissues. These results showed that there is no difference between the different screw brands, being all biocompatible. The osseous necrosis seen is possible due to the trauma caused by the drilling of the hole to insert the screws / Mestrado / Cirurgia Buco-Maxilo-Facial / Mestre em Clínica Odontológica
|
63 |
Sintese, caracterização e degradação de membranas de poli(acido-latico), um polimero bioabsorvivelLuciano, Rubens Monteiro 29 August 1996 (has links)
Orientadores: Eliana Aparecida de Rezende Duek, Carlos Kenichi Suzuki / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-22T23:54:27Z (GMT). No. of bitstreams: 1
Luciano_RubensMonteiro_M.pdf: 8494104 bytes, checksum: f9097ee1b100ace062106956eb3945d4 (MD5)
Previous issue date: 1997 / Resumo: Polímeros com função estrutural temporária para auxiliar na recuperação de tecidos vivos lesados vem se tomando uma área de pesquisa muito promissora. Um destes polímeros é o poli(ácido-lático) que pode ser utilizado sob a forma de membranas que funcionam como suporte para fixação e crescimento celular (derme artificial, lesões internas, transplante de células) ou como separação entre tecidos moles e tecidos ósseos em recuperação (regeneração guiada de tecido). Neste trabalho, cinco tipos diferentes de membranas, três com e duas sem plastificante foram sintetizadas. O objetivo foi correlacionar os parâmetros de síntese e composição das membranas com a biocompatibilidade, morfologia, propriedades fisicoquímicas e propriedades mecânicas iniciais e após períodos de degradação de até 30 dias através de ensaios in vivo e in vitro. Para os ensaios in vivo, discos foram implantados em 15 ratos e trinta dias depois retirados e realizada a análise histológica. Nos ensaios in vitro, as membranas foram imersas em solução tampão fosfato e o processo de degradação foi acompanhado de dez em dez dias até trinta dias. Pelos resultados obtidos podemos concluir que é possível controlar a velocidade de degradação através da adição de plastificante,sem que isso comprometa a biocompatibilidadedo material. A adição do plastificante também modifica a membrana morfologicamente,tornado-a porosa. A porosidade contribui muito para a fixação e crescimento celular, porém toma a membrana bem mais frágil mecanicamente quando
comparada com uma membrana sem poros. Com estes resultados podemos dividir as membranas em dois grupos com distintas aplicações: membranas densas, bioabsorviveis, que não favorecem a invasão celular porém são biocompatíveis, indicadas para regeneração guiada de tecido e membranas porosas, também bioabsorviveis, facilmente invadidas por células, indicadas para recuperação e recomposlçâo de tecidos moles / Abstract: Poly(latic acid) (PLA) can play a central role in corporeal devices.PLA membrane possess adequate biocompatibility, hydrolysis degradation and absorption which make them suitable for use as biomaterial. They can be used as cell ingrowth matrix or insulating layer between soft and hard tissue. lt contributes to the tissue regeneration during convalescence. ln this piece of work
five types of PLA membrane were synthesised, some with plasticizer and others without it. Biocompatibility, morphology, physico-chemical and mechanical properties were evaluated using different synthesis parameters and chemical compositions. In Vivo and in Vitro tests were carried out to degrade the membranes. PLA discs were implanted in fifteen rats, after thirty days they
were extracted out and histologically analysed. For the In Vitro tests, PLA membranes were immersed in a phosphate buffer solution and the degradation process was followed up during thirty days. The results showed that membranes with plasticizer present a good tissue adhesion and porous structure. The yield strength and Young's modulus for the membranes with plasticizer are smaller than the one without plasticizer. The results obtained permit to conclude that the degradation velocity of membranes can be controlled by the addition of plasticizer, and it does not affect the biocompatibility of them. The addition of plasticizer can influence the morphology by
making the membrane more porous. The porosity can contribute for cell fixation and cell ingrowth, however the membranes with plasticizer are more fragile than the one without it. Concern to their application, PLA membranes can be classified into two groups:
-Dense bioabsorbable membranes, which does not contribute to the cell invasion that can be used as guide for tissue regeneration;
-Flexible and porous membranes that can be used as soft tissue recomposition and regeneration / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
|
64 |
Sintese e caracterização do Poli (L-acido lactico) - PLLA e Poli (L-acido lactico-co- acido glicolico) - PLGA e estudo da degradação "in vitro"Monteiro, Adriana Cristina Motta de Menezes 23 August 2002 (has links)
Orientador: Eliana Aparecida de Rezende Duek / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-03T00:27:03Z (GMT). No. of bitstreams: 1
Monteiro_AdrianaCristinaMottadeMenezes_M.pdf: 8387510 bytes, checksum: d872fbb7fa9fc469c2476debde805175 (MD5)
Previous issue date: 2002 / Resumo: O estudo e aplicação de poliésteres bioareabsorvíveis para reparar tecidos danificados tem se mostrado uma área de pesquisa muito promissora. Poli (L-ácido láctico), PLLA, e Poli(ácido lactico-co-ácido glicólico), PLGA, se destacam dentre os poliésteres bioreabsorvíveis, em função da excelente biocompatibilidade propriedades mecânicas. Os objetivos deste trabalho foram sintetizar e caracterizar o PLLA _ o PLGA e estudar a degradação in vitro de membranas preparadas a partir desses polímeros. Os polímeros foram sintetizados através da abertura dos dímeros cíc1icos do ácido láctico, lactide, e do ácido glicólido, glicolide, utilizando-se como catalisador o Sn(Oct)2. Os polímeros PLLA e o PLGA apresentaram altos valores de massa molar ( Mw em tomo de 105 glmol) e suas estruturas químicas foram confinadas através de R.MN de 1 H e C 13 e IV. As propriedades térmicas do PLLA e PLGA foram estudadas por DSC _ TGA, sendo verificada uma alta cristalinidade para o homopolímero e uma baixa çristalinidade para o copolímero. O estudo da degradação "in vitro" de suas membranas confirmou a mais rápida degradação do PLGA comparado ao PLLA. Este estudo mostrou que o custo para as sínteses de PLLA e PLGA pode ser reduzido de 4-5 vezes comparado aos polímeros importados / Abstract: The study and application of bioreabsorbable polyesters to repair damaged tissue is & very promising research area. Poly (L-lactic acid), PLLA, and Poly (lactic acid-co-glicolic acid), PLGA, are the most important bioreabsorbable polyesters due to their excellent biocompatibility and mechanical properties. In this work PLLA and PLGA were synthesized and characterized, and in vitro degradation of membranes was evaluated. The polymers were synthesized by ring opening of the cyclic diester of lactic acid, lactide, and g!icolic acid, glicolide using Sn(Octh catalyst. PLLA and PLGA polymers presented high values of molar mass (Mw around 105 g/mol) and their chemical structures were confirmed by IH and 13C NMR and IV. PLLA and PLGA thermal properties were studied by DSC and TGA, being verified that the homopolimer has a high crystallinity and copolymer has a low crystallinity. 1n vitro degradation study confirmed that the degradation process of PLGA membranes is faster than PLLA ones. This study showed that the synthesis of PLLA and PLGA costs can be decreased for 4-5 times compared to imported materials / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
|
65 |
Obtenção, caracterização e estudo in vitro de microesferas de PLLA e da blenda PLLA/PEO para liberação controlada do cloridrato de vancomicinaCeroni Filho, Alberto Sergio, 1973- 03 August 2018 (has links)
Orientador : Eliana Aparecida de Rezende Duek / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-03T22:50:00Z (GMT). No. of bitstreams: 1
CeroniFilho_AlbertoSergio_M.pdf: 5591536 bytes, checksum: 4e6e13eb7c0734147a5f95f65ad3fa7d (MD5)
Previous issue date: 2004 / Mestrado
|
66 |
Sintese de vidros e vitro-ceramicas do sistema SiO2-AL2O3-CaO-CaF2 por Sol-Gel : caracterização e aplicação em cimentos de ionomero de vidroZolotar, Mayard Samis 24 June 1999 (has links)
Orientadores: Cecilia Amelia de Carvalho Zavaglia, Carlos Kenichi Suzuki / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-25T02:17:04Z (GMT). No. of bitstreams: 1
Zolotar_MayardSamis_D.pdf: 11942077 bytes, checksum: ae0c7cdf8edae46bf7424f399368d715 (MD5)
Previous issue date: 1999 / Resumo: Este trabalho teve como objetivos a síntese, através do processo sol-gel, de vidros e vitrocerâmicas de diferentes composições, no sistema SiOrAhO3-CaO-CaF2, formulação básica do componente inorgânico dos cimentos de ionômero de vidro comerciais, sua caracterização microestrutural e uma avaliação preliminar do tempo de cura e da resistência mecânica à compressão dos cimentos obtidos a partir destes materiais. Utilizou-se a técnica de modelagem de misturas na seleção das composições sintetizadas neste trabalho. A caracterização dos vidros e vitro-cerâmicas obtidos realizou-se através de análise química por fluorescência de raios-x e espectroscopia de plasma, diftação de raios-x, análises termogravimétrica e termodiferencial,
espectroscopia de Ínftavermelho com transformada de Fourier, espectroscopia RAMAN, microscopia eletrônica de varredura convencional, acoplada à análise dispersiva de raios-x e microscopia eletrônica de alta resolução. Concluiu-se ser possível obter vidros e vitro-cerâmicas ricos em flúor, em temperatura ambiente, através da técnica de processamento sol-gel. Está última mostrou-se adequada para a síntese de vidros e vitro-cerâmicas do sistema estudado, sendo estes últimos aplicáveis como componentes inorgânicos de cimentos de ionômero de vidro para uso odontológico / Abstract: The present work aimed at the synthesis of sol-gel glasses and glass ceramics in the SiO2-AhO3-CaO-CaF2 system, the basic formulation of the inorganic component of commercial glass ionomer cements, their microstructure characterisation, and a preliminary evaluation of the setting time and compressive strength of the cements obtained from these materials. The compositions employed in this work were chosen from a design generated through the mixture design technique. The characterisation of the sol-gel glasses and glass-ceramics was carried out by chemical analysis through x-ray fluorescence and inductive coupled plasma spectroscopy, x-ray diffraction, thermogravimetry and differential thermal analysis, infrared and RAMAN spectroscopies, conventional scanning electron microscopy with x-ray dispersive analysis, and high resolution scanning electron microscopy. Fluorine-rich glass and glass-ceramics were obtained at room temperature through the sol-gel processing technique. The latter also proved to be adequate for the synthesis of glasses and glass-ceramics in the above system which are suitable to be used as the inorganic component of glass ionomer dental cements / Doutorado / Materiais e Processos de Fabricação / Doutor em Engenharia Mecânica
|
67 |
Estudo in vitro da compatibilidade do osso bovino misto quimicamente tratadoTakamori, Esther Rieko 02 November 2004 (has links)
Orientador: Jose Mauro Granjeiro / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-08-04T03:03:24Z (GMT). No. of bitstreams: 1
Takamori_EstherRieko_M.pdf: 4278363 bytes, checksum: 0d831343742c2db28de42970dad8d707 (MD5)
Previous issue date: 2004 / Resumo: Dentre os biomateriais que visam auxiliar a regeneração óssea, destacam-se os de origem bovina. Têm sido avaliados diferentes protocolos de tratamento químico do osso bovino com a finalidade de preservar os componentes orgânicos (colágeno) e inorgânicos (hidroxiapatita), resultando no Osso Bovino Misto (OBM), a fim de aumentar a resistência mecânica do material. Apesar do OBM apresentar-se como um material promissor para uso na clínica médico-odontológica, por conciliar resistência e resiliência, deve-se certificar a ausência de efeitos tóxicos ou ativação do sistema imune do organismo, ou seja, sua biocompatibilidade. O objetivo deste trabalho foi avaliar a citocompatibilidade do OBM por
meio de testes de citotoxicidade (Norma ISO 10993), análise morfológica e estudo da interação célula-material. Os ensaios de citotoxicidade consistiram de contagem de células, redução do MTT e captação do Vermelho Neutro. Nesses testes, células da linhagem Balb/c 3T3 foram incubadas com diferentes concentrações do extrato puro do OBM (100mg/mL), a 37oC, 24 h. Nesses ensaios, verificamos diferença estatisticamente
significante entre o grupo controle (não tratado) e as concentrações superiores a 50 mg/mL (p<0,01, Análise de Variância, teste de Tukey), similar à proporcionada pelo GENOX ® orgânico e GEN-OX® inorgânico, comercialmente disponíveis. Estes resultados foram confirmados pela análise da morfologia das células tratadas nas diferentes condições, utilizando microscopia óptica de luz. A análise da interação célula-material (por
microscopia eletrônica de varredura) somente foi possível após diálise do material (água deionizada) e condicionamento (72 h) em Meio de Eagle modificado por Dulbecco (DMEM) + 10% Soro Fetal Bovino (SFB). Concluímos que concentrações do extrato do OBM acima de 50 mg/mL diminuem significativamente o número de células, as funções mitocondrial e lisossomal. Provavelmente isto se deve à presença de resíduos do processamento do material, indicando a necessidade de otimização do processo / Abstract: Biomaterials have been developed and investigated aiming to help bone regeneration. Xenografts of bovine origin stand out due to their biocompatibility, low cost and availability. Some protocols have been tested to develop a chemically treated material containing the anorganic (hydroxiapatite) and the organic (collagen) components of bovine boned: the mixed bovine bone (MBB). In spite of the MBB has been shown as a
promising material for dental and medical applications, due to its resistance and resilience, it must be certified that this material is atoxic and do not activate the immunological system of the organism. The purpose of this investigation was to evaluate the MBB cytocompatibility by the use of cytotoxicity tests (ISO 10993), morphological analysis and cell-material interaction studies. The cytotoxicity assays consisted of cell number
determination, MTT reduction and Neutral Red uptake. In these tests, Balb/c 3T3 cell lines were treated with different concentrations of MBB extract (100mg/mL, 37oC, 24h). Statistically significant differences were observed among control group (no treatment) and concentrations higher than 50 mg/mL (p< 0.01, ANOVA, Tukey¿s test), similar to results observed for organic and inorganic bovine bone (Gen-Ox®). Morphological analysis (optical
microscopy) confirmed these results. Cell-material interaction (scanning electron microscopy) was studied only after material dialysis and 72 h conditioning (Dulbecco Modified Eagle Medium, DMEM, plus 10% Fetal Calf Serum, FCS). Fibroblast proliferation and cell adhesion to the material were observed. We conclude that concentrations of MBB extract higher than 50mg/mL decreased significantly the cell number, mitochondrial and
lisosomal function. Probably toxic residues from manufacturing procedures remain in the material, indicating that process optimization should be considered. / Mestrado / Bioquimica / Mestre em Biologia Funcional e Molecular
|
68 |
Estudo biomecânico de dois modelos de implante não cimentado para a artroplastia total do quadril em modelo canino /Faria, Luís Guilherme de. January 2018 (has links)
Orientador: Bruno Watanabe Minto / Banca: Ana Paula Macedo / Banca: Sheila Canevese Rahal / Banca: Alexandre Schmaedecke / Banca: Luciane dos Reis Mesquita / Resumo: O objetivo deste estudo foi comparar as propriedades biomecânicas de dois modelos de hastes femorais da prótese total de quadril, não cimentada, modular e nacional. A haste A, possui uma extensão na base do colo do implante, denominado "colar", já o implante B, possui a sua porção proximal abaulada. Buscou-se determinar qual dos dois modelos de hastes femorais tem melhor desempenho ao evitar, ou impedir, o afundamento (subsidence). Para tal, utilizou-se 8 pares de fêmures de cães adultos, machos e fêmeas, de diferentes raças e massa corporal de ±25 kg. Em cada fêmur, uma ostectomia da cabeça e do colo femoral foi realizada e inserido um dos implantes selecionados. As construções foram submetidas, previamente, à radiografia e densitometria óssea, a fim de determinar a homogeneidade da amostra. Logo em seguida, divididos em dois grupos, Haste A (8 fêmures) e Haste B (8 fêmures), aplicou-se carga de flexo-compressão, no eixo axial de cada amostra, em máquina universal de ensaios. A força máxima, a deflexão, a resistência à compressão e a energia foram as variáveis analisadas nos dois sistemas, assim, o Grupo B exibiu valores significativamente maiores (p≤0,05) para as variáveis resultantes deste estudo, com exceção da rigidez que, estatisticamente, considerou-se similar entre os dois grupos (p=0,2031). A média da força máxima no teste de compressão axial para o Grupo A foi de 1347±357 N e, para o Grupo B, de 1805±123 N (p≤0,0069). A média da deflexão para o Grupo A foi de 5547±2... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The goal of this study was to compare the biomechanical properties of two models of femoral stems of the total hip, uncemented, modular, and national (Brazil) prosthesis. The stem A has an extension at the base of the implant, called the "collar", and the implant B, has its convex proximal portion. We sought to determine which of the two models of femoral rods perform best by avoiding, or preventing, subsidence. To this end, we used eight pairs of femurs of adult dogs, male and female, of different races and body weight ± 25 kg. In each femur, an ostectomy of the head and femoral neck was performed and inserted one of the selected implants. The constructs were previously submitted to radiography and bone densitometry, in order to determine the homogeneity of the sample. Then, divided into two groups, Stem A (8 femurs) and Stem B (8 femurs), a flexo-compression load was applied on the axial axis of each sample in a universal testing machine. Maximum strength, deflection, compressive strength and energy were the variables analyzed in both systems, thus, Group B showed significantly higher values (p≤0.05) for the variables resulting from this study, except for the rigidity that, statistically, it was considered similar between the two groups (p=0.2031). The mean maximal force in the axial compression test for Group A was 1347±357 N and, for Group B, 1805 ± 123 N (p≤0.0069). The mean deflection for Group A was 5547 ± 2639 mm and, for Group B, 10033±3998 mm (p≤0.0056). For the ene... (Complete abstract click electronic access below) / Doutor
|
69 |
Propriedades anisotrópicas e refrativas de córneas de coelhos, após implantação de inlays de colágeno tipo I extraído de tendão flexor digital superficial de bovino /Barros Sobrinho, Alexandre Augusto Franchi de. January 2019 (has links)
Orientador: José Luiz Laus / Coorientador: Marcela Aldrovani Rodrigues / Banca: Cláudia Valéria Seullner Brandão / Banca: Ivan Ricardo Martinez Padua / Banca: Roberta Martins Crivelaro / Banca: Marcia Rita Fernandes Machado / Resumo: Membranas a base de colágeno tipo I extraído de tendão flexor digital superficial bovino foram estudados como possível matéria prima para confecção de inlays corneais. Elas foram implantadas nos estromas corneais de olhos direitos de 16 coelhos da raça Nova Zelândia Branco, adultos, machos ou fêmeas, em higidez sistêmica. Um "bolso" foi criado na região central de cada córnea para implantação e posicionamento da membrana (inlay) dentro do estroma anterior (grupo CM, 16 coelhos). Córneas com "bolso", sem implantação de membranas (grupo SM, 16 coelhos), bem como córneas intactas (grupo controle, 4 coelhos sem qualquer procedimento cirúrgico) foram estudadas. Os grupos CM e SM foram avaliados clinicamente quanto a presença de blefarospasmo, hiperemia conjuntival, edema, secreção ocular e neovascularização e quanto às propriedades refrativas e a curvatura da córnea imediatamente antes (basal) e transcorridos 3, 7, 14, 21 e 28 dias de pós-operatório. Quatro animais dos grupos CM e SM, escolhidos ao acaso, foram submetidos à eutanásia ativa, em diferentes tempos, para colheita de córneas, as quais juntamente com córneas intactas do grupo controle, foram processadas para estudos comparativos em anisotropias ópticas (birrefringências total, de forma e intrínseca). Todas as variáveis contínuas foram testadas para a normalidade estatística. Diferenças com p < 0,05 foram consideradas significativas. Os procedimentos cirúrgicos realizados na córnea dos animais do grupo SM não alteraram a... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Membranes based on type I collagen extracted from bovine superficial digital flexor tendon were studied as a possible raw material for making corneal inlays. They were implanted in the right-eye, on the corneal stroma of 16 New Zealand White rabbits, male or female, adults, in apparently systemic health. A "pocket" was created in the central region of the cornea for implantation and positioning of the membrane (inlay) within the anterior stroma (CM group, 16 rabbits). Corneas with pocket, without implantation of membranes (SM group, 16 rabbits), as well as intact corneas (control group, 4 rabbits without any surgical procedure) were studied. The CM and SM groups were clinically evaluated for the presence of blepharospasm, conjunctival hyperemia, edema, ocular secretion and neovascularization, and on the refractive properties and curvature of the cornea immediately before (baseline) and after 3, 7, 14, 21 and 28 days of the postoperative period. Four animals, randomly choose from CM and SM groups were submitted to active euthanasia at different times to harvest the corneas, which, together with intact corneas from the control group, were processed for comparative studies in optical anisotropy (total, form and intrinsic birefringences). All continuous variables were tested for statistical normality. Differences with p <0.05 were considered significant. Surgical procedures performed on the corneas of the SM group did not alter the refraction (p = 0.479). The corneas in the CM gr... (Complete abstract click electronic access below) / Doutor
|
70 |
Mapeamento estratégico dos biomateriais utilizados em implantes /Santos, Gustavo Roberto dos January 2019 (has links)
Orientador: Antonio Carlos Guastaldi / Resumo: Com os avanços cada vez mais rápidos da tecnologia na área da saúde e com a evolução no desenvolvimento de novos materiais, produtos e técnicas cirúrgicas, tornou-se possível aos profissionais a realização de procedimentos de forma mais eficiente, bem como, aos pacientes, a recuperação mais acelerada e a melhora na qualidade de vida. O objetivo deste trabalho é desenvolver um mapeamento estratégico dos biomateriais utilizados em implantes na área da saúde, buscando uma compreensão do mercado e da área de pesquisa e desenvolvimento. Foram feitas pesquisas nas bases de dados científicos Scopus e Web of Science, e levantamento de dados econômicos nas bases da Abimo e Comex Stat, utilizando o processo de busca estruturada baseado no método Systematic Search Flow (SSF). A estratégia de busca inclui levantar dados no período de 2012 a 2018 relacionados com as áreas de aplicação: Cardiologia, Dental, Ortopedia e Oftalmologia; e com os grupos de materiais: Metais, Polímeros, Cerâmicas e Naturais. Das duas bases de dados utilizadas, a Scopus apresentou uma maior quantidade de documentos publicados, cerca de 58,49% contra 51,51% da Web of Science. Em relação ao progresso da produção cientifica na área de biomateriais, podemos afirmar que os Metais constituem a parcela da ciência dos materiais que mais tem revelado interesse dos pesquisadores no desenvolvimento de pesquisas, buscando novas técnicas e métodos para melhorar a qualidade de vida das pessoas. Foram 20.167 publicações realiza... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: With the ever-faster advances in technology used on healthcare area and thedevelopment of new materials, products and surgical techniques, it has becomepossible for professionals in this field to perform procedures more efficiently, as well,for patients, a faster recovering and improvement on quality of life. The objective ofthis work is to develop a strategic mapping of biomaterials used in implants on healtharea, seeking an understanding of the market and Research & Development area.Researches into scientific data bases Scopus and Web of Science were performed, aswell economic searching into Abimo and Comex Stat databases using the structuredprocess based on the Systematic Search Flow (SSF) method. The search strategyincludes collecting data from 2012 to 2018 related to the following application areas:Cardiology, Dental, Orthopedics and Ophthalmology; also, with the material groups:Metals, Polymers, Ceramics and Naturals. Among the two databases used, Scopushas presented the largest number of published articles, about 58.49% against 51.51%of Web of Science. Regarding to the progress of scientific production in biomaterialsarea, we can say that in the material science, Metals are the most interest indevelopment of research, seeking new techniques and methods to improve people'squality of life. There were 20,167 publications made in the period, where 50.56% arefrom the Metals group. In Brazil, there is a prevalence of small and medium compani... (Complete abstract click electronic access below) / Mestre
|
Page generated in 0.123 seconds