• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 392
  • 45
  • 15
  • 11
  • 10
  • 10
  • 10
  • 9
  • 1
  • 1
  • 1
  • Tagged with
  • 456
  • 101
  • 74
  • 70
  • 70
  • 65
  • 62
  • 54
  • 50
  • 47
  • 44
  • 42
  • 40
  • 40
  • 34
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
431

Catalisadores de CuO, Fe2O3 ou Co3O4 suportados em TiO2, CeO2 ou ZrO2: preparação via Sol-gel in situ ou impregnação e avaliação na redução de NO com CO

Pereira, Cristiane Alves Sierra 13 April 2012 (has links)
Made available in DSpace on 2016-06-02T19:55:32Z (GMT). No. of bitstreams: 1 4381.pdf: 2748711 bytes, checksum: 4ba9831d0665b24b6f48f775d30927d2 (MD5) Previous issue date: 2012-04-13 / Universidade Federal de Minas Gerais / The minimization of the emissions of nitrogen oxides (NOx) is a subject of crucial interest, since them cause serious environmental problems which affect human health, vegetation and fauna. With the purpose to abate NOx, processes involving their catalytic reduction show strong potential. In the case of the reduction of NO with CO a meaningful advantage arises, once both pollutants are removed simultaneously. In order to obtain efficient and stable catalysts for this reaction, many studies have been done with the aim to improve the catalytic activity by achieving a better favorable metal-support interaction to the occurrence of the reaction and a better distribution of the active phases on the support. In this context, the objective of this study was to prepare Cu, Fe and Co based catalysts supported on TiO2, CeO2 and ZrO2 to be applied in the abatement of NO with CO. The addition of the precursors of the active phases was made during the synthesis of the support via the sol-gel method (in situ addition). Furthermore, catalysts with the same composition were prepared by conventional methods. Results from the N2 adsorption/desorption measurements show that the sol-gel method was efficient to prepare supports with improved textural properties. H2-TPR and UVVIS-DRS data evidenced the presence of Cu, Fe or Co oxides in the respective catalysts, which mostly did not show characteristic X-ray diffraction peaks of those oxide phases, suggesting their high dispersion on the supports. In general, results of the reduction of NO to N2 with CO revealed that the catalysts prepared via sol-gel are as active as those prepared by conventional routes, which demonstrate the great potential of the catalysts preparation via the sol-gel in situ procedure, which diminishes the number of the synthesis steps saving time and energy. In general, among the studied supports, ceria presented a more favorable metal-support interaction. In the presence of O2, SO2 and water steam, catalysts 6,5Cu/CeP, 5,5CuZrSG and 8,4Fe/TiC showed no significant changes in their activity and selectivity, indicating that they present high stability to be used under the severe conditions of real processes. / A minimização das emissões de óxidos de nitrogênio (NOx) é assunto de interesse crucial, pois geram graves problemas ambientais que afetam à saúde humana, à flora e à fauna. Para abater os NOx, processos envolvendo à sua redução catalítica apresentam forte potencial. No caso da redução catalítica de NO com CO, tem-se a vantagem adicional de minimizar as emissões de ambos poluentes. Para a obtenção de catalisadores eficientes e estáveis para essa reação, muitos estudos têm sido desenvolvidos no sentido de aumentar a atividade por meio de uma interação metalsuporte mais favorável ao processo reativo e de se conseguir uma melhor distribuição da fase ativa no suporte. Nesse contexto, o objetivo do presente estudo foi preparar catalisadores para a redução de NO com CO à base de óxido de Cu, Fe ou Co, suportados em TiO2, CeO2 ou ZrO2, com a adição do precursor da fase ativa durante a preparação do suporte via processo sol-gel (adição in situ). Além disso, catalisadores de mesma composição foram preparados por rotas convencionais. Resultados de medidas de adsorção/dessorção de N2 dos suportes mostram que o método sol-gel utilizado é mais eficiente no preparo de suportes com propriedades texturais melhoradas. Análises de RTP-H2 e ERD-UVVIS evidenciaram a presença dos óxidos de Cu, Fe ou Co em todos os catalisadores, os quais, em sua maioria, não apresentaram picos de difração de raios X característicos dessas fases, o que sugeriu sua alta dispersão no suporte. Em geral, os resultados da redução de NO a N2 com CO mostraram que os catalisadores preparados pelo método sol-gel in situ são tão ativos quanto os catalisadores preparados por métodos convencionais, o que demonstra o forte potencial desse procedimento, que resulta no uso de um número menor de etapas na preparação do catalisador, com a consequente economia de tempo e energia. De maneira geral, dentre os suportes estudados a céria mostrou uma relação metal-suporte mais favorável ao processo de óxidoredução. Os catalisadores 6,5Cu/CeP, 5,5Cu-ZrSG e 8,4Fe/TiC, na presença de O2, SO2 e vapor de água não apresentaram alteração significativa da sua atividade e seletividade, mostrando uma alta estabilidade para atuar sob as drásticas condições dos processos reais.
432

Estudo da qualidade dos corpos hídricos do Parque das Águas em Pinhais/PR

Ferreira, Sheila Cristhina da Rocha 31 October 2012 (has links)
CAPES / Os corpos hídricos têm suas características afetadas pela poluição difusa, por meio do carreamento de poluentes pelo escoamento superficial nos eventos de chuvas ou também por despejos pontuais. Esta pesquisa foi realizada nas cavas do Parque das Águas em Pinhais/PR e teve por objetivo avaliar a qualidade das águas e sedimentos dos corpos hídricos e a sua correlação com a poluição difusa. Foram analisadas algumas variáveis físico-químicas, bacteriológicas e de compostos orgânicos HPAs e n-Alcanos em 6 pontos, que podem indicar possíveis alterações na qualidade desses corpos hídricos. Estas cavas deverão futuramente ser destinadas para uso de recreação de contato secundário, como pesca e esportes náuticos pela LEI No 189/87 - Pinhais, indicando que as águas dessas cavas devem atender a resolução CONAMA 357/05, que estabelece limites para parâmetros físico- químicos, biológicos e de espécies metálicas que possam causar danos à saúde e ao ambiente. Para embasar a discussão dos resultados para HPAs e espécies metálicas em sedimento, utilizou-se a resolução CONAMA 344/04. Os limites indicados pelas resoluções do CONAMA 357/05 e 344/04, são valores de segurança. Com base nos resultados obtidos, identificou-se a influência das chuvas nas concentrações das variáveis analisadas. Através da comparação dos resultados com a Resolução CONAMA 357/05 para água doce de classe 2, pôde ser constatado que os parâmetros salinidade, OD, turbidez, amônia, nitrito, nitrato estão de acordo com os limites impostos pela resolução, a DBO a para maioria dos pontos analisados apresentou-se dentro dos limites, porém em um dos pontos excedeu o limite. Para Coliformes termotolerantes, a maior parte dos pontos se apresentou dentro dos limites estabelecidos pela resolução. A variável Sulfeto não atende a CONAMA 357/05. Dos sete metais analisados em água cádmio e ferro apresentam-se acima do limite para o CONAMA 357/05. Os metais cobre, zinco, cádmio, níquel e chumbo em sedimentos estão dentro do limite da resolução CONAMA 344/04, mas em alguns pontos amostrados os HPAs indicaram contaminação por elementos de origem petrogênica quando confrontados com os limites indicados nesta mesma resolução. Para evitar que os limites sejam excedidos, visto que alguns dos pontos amostrados estão muito próximos, ou extrapolando os limites indicados, faz-se necessário evitar a entrada de poluente nas cavas do parque em questão, devido ao grande risco de perder a qualidade destes corpos hídricos e prejudicar a sua função para a sociedade. A pesquisa permitiu identificar que o incremento da carga poluente é potencializado pelo escoamento superficial das chuvas, inferindo desta forma, a necessidade do controle da poluição difusa para a área do parque. Uma das possíveis soluções seria a implantação de sistemas de wetlands construídos, que podem funcionar como barreiras para a entrada de poluentes, principalmente nas cavas mais próximas às estruturas viárias pavimentadas. / The water bodies have the characteristics affected by diffuse pollution through the drift of pollutants in the runoff from rain events or also by occasional evictions. This research was conducted in pools of the Water Park in Pinhais/PR and aimed to assess the quality of waters and sediments of water bodies and their correlation with diffuse pollution. The analyses from some physico-chemical, bacteriological and organic compounds PAHs and n-alkanes in 6 points, indicated possible changes in the quality of these water bodies. These pools will be designed for future use of secondary contact recreation such as fishing and water sports in the LAW 189/87 - Pinhais-PR, indicating that the water pools must answer these CONAMA Resolution 357/05, which sets limits for physical- chemical, biological and metal species that may cause damage to health and the environment. To support the discussion of the results for PAHs in sediment and metal species, is used the CONAMA Resolution 344/04. The limits given by CONAMA resolutions 357/05 and 344/04, are safety values. Based on these results, we identified the influence of rainfall in the concentrations of all variables. By comparing the results with CONAMA Resolution 357/05 for freshwater class 2, it might be noted that the parameters salinity, dissolved oxygen, turbidity, ammonia, nitrite, nitrate comply with the limits imposed by resolution, for the DBO Most points analyzed was within the limits, but in one of the exceeded limit. For Fecal coliform, most points are presented within the limits established by resolution. The variable sulfide does not meet CONAMA 357/05. Of the seven metals analyzed in water cadmium and iron are found above the ceiling for CONAMA 357/05. The metals copper, zinc, cadmium, nickel and lead in sediments are within the limit of CONAMA Resolution 344/04, but in some sampling sites indicated PAH contamination source elements petrogenic when confronted with the limits specified in this same resolution. To avoid the exceeding the limits, since some of the points are very close, or extrapolating the limits, it is necessary prevent the entry of polluting the pools of the park in question, due to the high risk of losing the quality of these bodies water and impair its function for society. The research identified that the increase in pollution load is powered by the runoff of rainfall, implying thus the need for control of diffuse pollution to the park area. One of the possible solutions would be the deployment of constructed wetlands, which can act as barriers to the entry of pollutants, mainly pools nearest paved road structures.
433

Estudo da qualidade dos corpos hídricos do Parque das Águas em Pinhais/PR

Ferreira, Sheila Cristhina da Rocha 31 October 2012 (has links)
CAPES / Os corpos hídricos têm suas características afetadas pela poluição difusa, por meio do carreamento de poluentes pelo escoamento superficial nos eventos de chuvas ou também por despejos pontuais. Esta pesquisa foi realizada nas cavas do Parque das Águas em Pinhais/PR e teve por objetivo avaliar a qualidade das águas e sedimentos dos corpos hídricos e a sua correlação com a poluição difusa. Foram analisadas algumas variáveis físico-químicas, bacteriológicas e de compostos orgânicos HPAs e n-Alcanos em 6 pontos, que podem indicar possíveis alterações na qualidade desses corpos hídricos. Estas cavas deverão futuramente ser destinadas para uso de recreação de contato secundário, como pesca e esportes náuticos pela LEI No 189/87 - Pinhais, indicando que as águas dessas cavas devem atender a resolução CONAMA 357/05, que estabelece limites para parâmetros físico- químicos, biológicos e de espécies metálicas que possam causar danos à saúde e ao ambiente. Para embasar a discussão dos resultados para HPAs e espécies metálicas em sedimento, utilizou-se a resolução CONAMA 344/04. Os limites indicados pelas resoluções do CONAMA 357/05 e 344/04, são valores de segurança. Com base nos resultados obtidos, identificou-se a influência das chuvas nas concentrações das variáveis analisadas. Através da comparação dos resultados com a Resolução CONAMA 357/05 para água doce de classe 2, pôde ser constatado que os parâmetros salinidade, OD, turbidez, amônia, nitrito, nitrato estão de acordo com os limites impostos pela resolução, a DBO a para maioria dos pontos analisados apresentou-se dentro dos limites, porém em um dos pontos excedeu o limite. Para Coliformes termotolerantes, a maior parte dos pontos se apresentou dentro dos limites estabelecidos pela resolução. A variável Sulfeto não atende a CONAMA 357/05. Dos sete metais analisados em água cádmio e ferro apresentam-se acima do limite para o CONAMA 357/05. Os metais cobre, zinco, cádmio, níquel e chumbo em sedimentos estão dentro do limite da resolução CONAMA 344/04, mas em alguns pontos amostrados os HPAs indicaram contaminação por elementos de origem petrogênica quando confrontados com os limites indicados nesta mesma resolução. Para evitar que os limites sejam excedidos, visto que alguns dos pontos amostrados estão muito próximos, ou extrapolando os limites indicados, faz-se necessário evitar a entrada de poluente nas cavas do parque em questão, devido ao grande risco de perder a qualidade destes corpos hídricos e prejudicar a sua função para a sociedade. A pesquisa permitiu identificar que o incremento da carga poluente é potencializado pelo escoamento superficial das chuvas, inferindo desta forma, a necessidade do controle da poluição difusa para a área do parque. Uma das possíveis soluções seria a implantação de sistemas de wetlands construídos, que podem funcionar como barreiras para a entrada de poluentes, principalmente nas cavas mais próximas às estruturas viárias pavimentadas. / The water bodies have the characteristics affected by diffuse pollution through the drift of pollutants in the runoff from rain events or also by occasional evictions. This research was conducted in pools of the Water Park in Pinhais/PR and aimed to assess the quality of waters and sediments of water bodies and their correlation with diffuse pollution. The analyses from some physico-chemical, bacteriological and organic compounds PAHs and n-alkanes in 6 points, indicated possible changes in the quality of these water bodies. These pools will be designed for future use of secondary contact recreation such as fishing and water sports in the LAW 189/87 - Pinhais-PR, indicating that the water pools must answer these CONAMA Resolution 357/05, which sets limits for physical- chemical, biological and metal species that may cause damage to health and the environment. To support the discussion of the results for PAHs in sediment and metal species, is used the CONAMA Resolution 344/04. The limits given by CONAMA resolutions 357/05 and 344/04, are safety values. Based on these results, we identified the influence of rainfall in the concentrations of all variables. By comparing the results with CONAMA Resolution 357/05 for freshwater class 2, it might be noted that the parameters salinity, dissolved oxygen, turbidity, ammonia, nitrite, nitrate comply with the limits imposed by resolution, for the DBO Most points analyzed was within the limits, but in one of the exceeded limit. For Fecal coliform, most points are presented within the limits established by resolution. The variable sulfide does not meet CONAMA 357/05. Of the seven metals analyzed in water cadmium and iron are found above the ceiling for CONAMA 357/05. The metals copper, zinc, cadmium, nickel and lead in sediments are within the limit of CONAMA Resolution 344/04, but in some sampling sites indicated PAH contamination source elements petrogenic when confronted with the limits specified in this same resolution. To avoid the exceeding the limits, since some of the points are very close, or extrapolating the limits, it is necessary prevent the entry of polluting the pools of the park in question, due to the high risk of losing the quality of these bodies water and impair its function for society. The research identified that the increase in pollution load is powered by the runoff of rainfall, implying thus the need for control of diffuse pollution to the park area. One of the possible solutions would be the deployment of constructed wetlands, which can act as barriers to the entry of pollutants, mainly pools nearest paved road structures.
434

Estudo do efeito magnetocalórico e barocalórico de sistemas magnéticos baseados em Mn

Silva Júnior, José Almeida da 16 March 2017 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / In this work we detail the magnetoelastic coupling method in which the elastic term is absorbed by the exchange term allowing it to obtain additional contributions, Sadd, to the total entropy variation, by means of the dependence of the exchange parameter (T;H; P). For this purpose, we proposed the dependence of the bulk modulus with temperature, B(T), for the linear case (L-case) and Wachtman type (W-case), thus verifying that the total entropy variation , SMaxwell, is the sum of the conventional entropy variation, Sconv, with the additional contribution, that is, SMaxwell = Sconv + Sadd. In addition, we analyzed: i) the action of hydrostatic pressure on magnetic and magnetocaloric properties for both L and W cases, where there was a reduction in transition temperature, TC, a change in nature of the magnetic transition and the increase in the intensity of the magnetocaloric e ect, Siso, keeping constant the area under the curves, with increasing pressure; (ii) the action of the magnetic eld on the barocaloric properties, where an increase in TC and a reduction of the barocaloric e ect, bar iso , could be observed, constant keeping the area under the curves, with the increase of the magnetic eld, thus verifying that the barocaloric e ect is energetically more e cient under the action of low elds than the magnetocaloric e ect; and (iii) the action of the magnetic eld and the pressure simultaneously, verifying an alternative way to potentiate the magnetocaloric e ect for a wide temperature range, which makes possible to apply the results to other systems besides MnAs and their parents. Finally, an extension of the Kubo and Ohata model, similar to Bean-Rodbell, was presented for the manganites, La1-xCaxMnO3 and La2=3(Ca1-xSrx)1=3MnO3, in the presence of magnetic eld, thus describing its magnetic, magnetocaloric, barocaloric and structural properties, by means of such magnitudes as: magnetization, variation of magnetic entropy, deformation, double exchange energy and electron conduction bandwidth eg, thus showing the connectivity between these quantities in the description of the physical properties of these compounds and showing an alternative model in the theoretical study of these manganites of Lanthanum. / Neste trabalho de pesquisa detalhamos o m etodo de acoplamento magnetoel astico no qual o termo el astico e absorvido pelo termo de troca possibilitando obter contribui c~oes adicionais, Sadd, a varia c~ao de entropia total, por meio da depend^encia do par^ametro de troca (T;H; P). Com esta nalidade, se prop^os a depend^encia do m odulo de volume com a temperatura, B(T), para o caso linear (caso-L) e do tipo Wachtman (caso-W), veri - cando assim que a varia c~ao de entropia total, SMaxwell, e a soma da varia c~ao de entropia convencional, Sconv, com a contribui c~ao adicional, ou seja, SMaxwell = Sconv+ Sadd. Al em disso, analisou-se: i) a a c~ao da press~ao hidrost atica nas propriedades magn eticas e magnetocal oricas para ambos os casos, L e W, onde veri cou-se uma redu c~ao na temperatura de transi c~ao, TC, uma mudan ca na natureza da transi c~ao magn etica e o aumento na intensidade do efeito magnetocal orico, Siso, mantendo a area sob as curvas constante, com o aumento da press~ao; ii) a a c~ao do campo magn etico nas propriedades barocal oricas, onde constatou-se um aumento em TC e uma redu c~ao do efeito barocal orico, Sbar iso , mantendo a area sob as curvas constante, com o aumento do campo magn etico, veri cando assim que o efeito barocal orico e energeticamente mais e ciente sob a c~ao de baixos campos do que o efeito magnetocal orico; e iii) a a c~ao do campo magn etico e da press~ao de forma simult^anea, veri cando uma forma alternativa de potencializar o efeito magnetocal orico para uma larga faixa de temperatura, sendo poss vel aplicar os resultados a outros sistemas, al em do MnAs e seus parentes. Por m, apresentou-se uma exten c~ao do modelo de Kubo e Ohata, similar ao de Bean-Rodbell, para as manganitas, La1-xCaxMnO3 e La2=3(Ca1-xSrx)1=3MnO3, em presen ca de campo magn etico, descrevendo assim as suas propriedades magn eticas, magnetocal oricas, barocal oricas e estruturais, por meio de grandezas como: magnetiza c~ao, varia c~ao de entropia magn etica, deforma c~ao, energia de dupla troca e largura da banda de condu c~ao dos el etrons eg, evid^enciando desta forma, a conectividade entre essas grandezas na descri c~ao das propriedades f sicas desses compostos e apresentando um modelo alternativo no estudo te orico destas manganitas de Lant^anio.
435

Propriedades eletrônicas e estruturais de clusters metálicos via métodos ab initio / Eletronic and strustural properties of metal clusters by ab initio methods

Damasceno Junior, Jose Higino 25 September 2015 (has links)
Submitted by Cláudia Bueno (claudiamoura18@gmail.com) on 2015-10-29T18:35:28Z No. of bitstreams: 2 Tese - Jose Higino Damasceno Junior - 2015.pdf: 2058291 bytes, checksum: ed4c947cd5e0f908dddc93570ac84dbb (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2015-11-03T14:21:33Z (GMT) No. of bitstreams: 2 Tese - Jose Higino Damasceno Junior - 2015.pdf: 2058291 bytes, checksum: ed4c947cd5e0f908dddc93570ac84dbb (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-11-03T14:21:33Z (GMT). No. of bitstreams: 2 Tese - Jose Higino Damasceno Junior - 2015.pdf: 2058291 bytes, checksum: ed4c947cd5e0f908dddc93570ac84dbb (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2015-09-25 / Fundação de Amparo à Pesquisa do Estado de Goiás - FAPEG / Clusters systems are very different from molecules or their bulk materials, since they exhibit many specific properties. As example, the bond in metallic clusters of metallic atoms is intermediate between metallic and covalent bonding. In general, the structural and electronic properties of these systems are very difficult to measure experimentally, and therefore theoretical modeling is very important in characterizing them. In this thesis, we employed ab initio methods to study metallic clusters such as the aluminum hydride clusters as well as a few aromatic metal clusters. The optimized geometries of the studied clusters have been determined using DFT. The electronic structures of these systems were investigated using the QMC methods. The calculations were carried out within the Variational (VMC) and fixed-node diffusion (DMC) quantum Monte Carlo methods. The calculations are also performed in the Hartree-Fock (HF) approximation in order to analyze the impact of electron correlation. With regards the aluminum hydride clusters, the total atomic binding energy impact varies from ~20% up to about ~50%, whereas for the electron binding energy it ranges from ~1% up to ~73%. The decomposition of the electron binding energies clearly shows that both charge redistribution and electron correlation are important in determining the detachment energies, whereas electrostatic and exchange interactions are responsible for the ionization potential. For the aromatic metal clusters, the presence of a dopant plays important role in their electronic properties enhancing their binding energy, electron affinity, hardness and resonance energy. / Clusters são sistemas bastante diferentes de moléculas e sólidos, pois exibem propriedades bastante peculiares. Por exemplo, a ligação em um cluster metálico tem intensidade intermediária entre as ligações covalentes e metálicas. Em geral, as propriedades eletrônicas e estruturais desses sistemas são bastante difíceis de serem medidas experimentalmente e, portanto, uma modelagem teórica é muito importante na caracterização desses. Nesta Tese, utilizamos métodos ab initio para estudar clusters metálicos, tal como clusters de hidretos de alumínio assim como também alguns clusters metálicos aromáticos. As estruturas geométricas dos clusters estudados foram otimizadas via DFT. A estrutura eletrônica desses clusters foi investigada usando o método de Monte Carlo Quântico Variacional (MCQD) e de difusão (MCQD) com aproximação de nós fixos. Os cálculos também foram realizados a partir da aproximação de Hartree-Fock, afim de se analisar o impacto da energia de correlação eletrônica. Para os hidretos de alumínio, a energia de correlação eletrônica tem impacto na energia total de ligação variando de 20% a 50%. Da mesma maneira, a energia de ligação de um elétron ao cluster tem grande contribuição da energia de correlação eletrônica, variando de 1% a 73%. A decomposição da energia de ligação mostra claramente que a relaxação e a correlação eletrônica são importantes na determinação da afinidade eletrônica, enquanto que a interação de troca eletrostática é responsável pelo potencial de ionização. Para os clusters aromáticos, a presença do dopante desempenha um importante papel nas propriedades desses clusters, uma vez que otimiza a energia de ligação, a afinidade eletrônica, a dureza e a energia de ressonância.
436

Avaliação da resistência à fratura de prótese parcial fixa provisória confeccionada sobre componentes do tipo UCLA em titânio - efeito de diversos reforços / Fracture resistance evaluation of provisional fixed partial denture made on titanium ucla components several reinforcements effect

Thania Grisel Rodriguez Almonte 31 May 2005 (has links)
As restaurações provisórias no tratamento reabilitador oral são de suma importância. Por isso é preocupante que os materiais utilizados para a execução das mesmas sejam críticos com relação à sua resistência e longevidade, principalmente, quando estas são executadas em tratamentos prolongados e/ou em espaços desdentados extensos. O objetivo deste trabalho foi avaliar em 4 grupos reforçados, compostos por 9 espécimes cada um, a resistência e o modo de fratura, de uma resina acrílica poli(metilmetacrilato) auto-polimerizável (Dencor® - Clássico®, São Paulo, SP, Brasil) utilizada para restaurações provisórias quando reforçada com fibras de vidro (Fibrante® e Interlig® - Angelus®, Londrina, PR, Brasil), fibras de aramida (Kevlar® - Du Pont®, USA) y fio ortodôntico &#x2205; 0, 7mm. E um grupo controle sem nenhum tipo de reforço, com a mesma quantidade de corpos de prova. A análise dos resultados (ANOVA, p < 0,05), para o teste de resistência, mostrou haver diferença estatística entre os grupos. O teste de Tukey encontrou que os grupos reforçados, aqueles que alcançaram maior média de resistência à fratura foram os que utilizaram a fibra de vidro trançada pré-impregnada com resina composta foto-polimerizável, Interlig® (1083 N); a fibra de vidro unidirecional préimpregnada com dimetacrilato de glicol, Fibrante® (1022 N) e a fibra de poli(aramida) unidirecional sem pré-impregnação, Kevlar® 29, aumentando em 26%, 22% e 17%, respectivamente, esta resistência em relação ao grupo controle (800 N), não havendo diferença estatística significante entre eles. O grupo reforçado com fio de aço com &#x2205; 0,7 mm (871 N) apareceu em seguida com uma resistência somente 8% maior e semelhante àquela apresentada pelo grupo controle sem reforço. A análise das fraturas concorreu com a elaboração de um novo sistema de classificação dividindo-as em quatro tipos: Ausente, Parcial, Total Não Separada e Total Separada. As fraturas dos espécimes reforçados foram consideradas mais favoráveis ocorrendo, predominantemente, os tipos Ausente e Parcial. / Provisional restorations are of ultimate importance in the oral rehabilitation treatment. Thus, clinicians have to bear in mind that materials used for their fabrication are critical due to its longevity and strength, when these are done for longterm therapy and/or large edentulous spaces. The aim of this work was to evaluate the flexural resistance and fracture mode of an auto-cure polymethylmetacrilate resin (Dencor® - Classico® , Sao Paulo, SP, Brasil) used for provisional restorations and reinforced with four materials. Samples were divided in four groups of nine each, as the following: glass fiber (Fibrante® and Interlig® Angelus®, Londrina, PR, Brasil), aramide fibers (Kevlar® Du Pont®, USA), and orthodontic wire &#x2205; 0,7mm. one group whitout reinforcement served as control. Data was submitted to statistical analysis with one-way ANOVA (p<.05) test. Results showed statistically significant difference among the groups. Tukeys test showed that glass-fiber Interlig® exhibited the greatest value of flexural strength (1083 N); followed by unidirectional glycol dimetacrylate glass-fiber Fibrante® (1022 N) and aramid fiber Kevlar® (966 N). These values represent 26%, 22% and 17% in relation to the control group (800 N), being non statistically significant difference observed among them. The group with &#x2205; 0,7mm orthodontic wire (871 N) had a resistance only 8% higher and similar of that of control group without reinforcement. Fracture analysis was conducted by the following scale: absence, partial, complete without separation, and complete with separation. Fracture modes observed on reinforced samples were considered more favorable, with types absent and partial seeing more frequently.
437

Bioacumulação de íons de Pb+² na macrófita Salvinia auriculata / Of the lead ions bioaccumulation process by living aquatic macrophytes Salvinia auriculata

Thomé, Luciara Ciane Port 13 February 2008 (has links)
Made available in DSpace on 2017-07-10T18:08:07Z (GMT). No. of bitstreams: 1 Luciara Ciane Port Thome.pdf: 1696527 bytes, checksum: f809752851373066f0420949b0b14357 (MD5) Previous issue date: 2008-02-13 / In this work was carried out a study of the lead bioaccumulation process by living aquatic macrophytes Salvinia auriculata. Initially, they were performed toxicological and growing tests in order to determine the non-toxic lead concentration limits and the minimum amount of biomass for the lead uptake experiment duration. The bioaccumulation experiment was performed using young and healthy floating aquatic plants of species S. auriculata. Approximately 30 grams of S. auriculata were put in growing at several 8-L recipients containing 5 L hydroponics solution and a non-toxic lead concentration of 2 mg L-1, during 29 days in a greenhouse. For the lead uptake experiment, seven collection times were set up at intervals of 1, 2, 5, 8, 22 and 29 days, including the zero time and was measured the growing solution temperature and pH, and the solution volume was monitored and deionized water was added to compensate the losses by evaporation. In order to measure the total lead concentration accumulated in aqueous solution obtaining from roots and leaves and growing solution, a Synchrotron Radiation Total Reflection X-Ray Fluorescence technique was used. The lead removal factor by S. auriculata after 29 days, in experimental conditions, was around 87 %. Moreover, it was observed a strong reduction of 50 % of lead concentration in liquid phase and lead accumulation in roots after the first 24 hours of experiment, while there a constant lead concentration in roots after the second day, indicating the transport and accumulation of lead into the leaves. The lead adsorption experimental data by S. auriculata were modeling by the irreversible adsorption kinetic of Langmuir. In the model, the equation system was resolved by DASSL algorithm and the kinetic parameters were obtained and optimized by an objective function using a SIMPLEX algorithm. The adsorption rate constant (k) value was 0.12 L d mg-1 Pb+2 while the maximum lead contents (qmax) value in the biomass was 0.15 mg Pb+2 g-1. The aquatic plant S. auriculata can be a good alternative for effluent treatment through both bioadsorption and bioaccumulation mechanism. The process based on the Phytoremediation technique using aquatic plants have become a attractive economical process due to its easy applicability , low operational costs and high efficiency. / Neste trabalho foi realizado um estudo do processo de bioacumulação de Pb+2 pela macrófita aquática Salvinia auriculata. Realizaram-se inicialmente testes toxicológicos e de crescimento para determinar os níveis tóxicos de Íons de Pb+2, estipular a massa mínima adequada, duração da experiência e os intervalos de coleta para o experimento da bioacumulação. O experimento da bioacumulação foi conduzido utilizando plantas jovens e sadias da espécie aquática e flutuante S. auriculata. Foram cultivadas, durante 29 dias em estufa, aproximadamente 30 gramas em recipiente de 8 L, em várias réplicas, contendo 5 litros de uma solução hidropônica (de Clark) e uma concentração não tóxica de 2 mg Pb+2 L-1. Foram realizadas 7 coletas, incluindo a coleta 0, a intervalos de 1, 2, 5, 8, 22 e 29 dias, monitorando pH e temperatura e fazendo a reposição de água devido a perdas por evaporação. As concentrações totais de chumbo, tanto na fase fluida como na raiz e na folha, foram determinadas pela técnica SR-TXRF. O fator de remoção de chumbo pela salvinia após 29 dias de cultivo, nas condições estudadas, foi de 87 %. Além disso, foi observado que a adsorção de chumbo foi rápida nas primeiras 24 horas, reduzindo em aproximadamente 50 %. A partir do segundo dia, a concentração de chumbo é quase constante, indicando a ocorrência de transporte e acumulação de chumbo na folha. Os dados experimentais de adsorção de Íons de Pb+2 pela S. auriculata foram representados pelo modelo cinético irreversível de Langmuir. No ajuste dos dados experimentais pelo modelo proposto, utilizou-se de uma função objetivo para otimizar os parâmetros de adsorção: a constante da taxa de adsorção e a quantidade máxima de sítios disponíveis na biomassa, cujos valores obtidos foram k = 0,12 L d mg-1 Pb+2 e qmax = 0,15 mg Pb+2 g-1. A planta S. auriculata mostrou-se uma boa opção para tratamento de efluentes através dos mecanismos de adsorção e bioacumulação. O processo de remoção de metal por planta aquática comprovou ser economicamente atrativo, de fácil disponibilidade, baixos custos operacionais e alta eficiência.
438

Cinética de bioacumulação do íon Pb+² na macrófita aquática Pistia stratiotes / Lead bioaccumulation kinetic by living aquatic macrophytes Pistia stratiotes

Costa Junior, Ismael Laurindo 13 December 2007 (has links)
Made available in DSpace on 2017-07-10T18:08:08Z (GMT). No. of bitstreams: 1 Ismael L Costa Junior.pdf: 1312326 bytes, checksum: fbf4a20b6caef1e0155c8eb9dea28ffe (MD5) Previous issue date: 2007-12-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In the present work the lead uptake onto a living free floating aquatic macrophyte Pistia stratiotes was investigated. The bioaccumulation mechanism were applied to understand the metal uptake by the autochthonous free floating Pistia, common in ponds and shallow lakes from southern Brazilian states from a hydroponics solution. The experiment was performed using several healthy acclimatized plants Pistia Stratiotes. For the metal uptake, aquatic plants were grown in plastic containers containing 5 L test liquids and 2 mg L-1 of into a greenhouse for 35 days. Twenty one replicates were used for metal treatment. Only healthy acclimatized plants of a uniform size and weight were selected for experimental purposes. Approximately 30 g wet weights of Pistia stratiotes were put into aqueous solution. The room temperature and pH were daily measured and deionized water was adding to compensate for water losses. Seven collections were carried out during five weeks which both plants and test liquids were collected from three replicate containers of each metal treatment. The plant wet weight was measured before the experiment and after the each collection. Plants were oven-dried at 80°C for 72 hours and weighted reducing their mass around 94 %, and then they were grinded and digested by acid attack. A Gallium internal standard was added to an aliquot of water or digested plant. An aliquot of 5µL was deposited on a pre-cleaned acrylic disk (ø30 mm, 3 mm thick) and dried at room temperature. Blank control samples containing de-ionized water and all reagents used in the experiment were prepared by the same procedure. Metal concentrations on dried weight plants and cultivation water were measured using the SR-TXRF. The data from the lead bioaccumulation experiment using living Pistia stratiotes have been represented by the irreversible Langmuir, reversible Langmuir, first order and second order models. The maximum capacity of lead removal (qmax ) and the kinetic constant of lead bioaccumulation (k) were the adjustable parameters. The model that described in more appropriate way the bioacumulação was of the kinetic of the reversible Langmuir, presenting a qmax of 0,21 mg g-1 and k of 0,69 L mg-1 d-1, what it demonstrates a good removal of Pb+2 to the long one of the time. / Neste trabalho investigou-se a remoção de íons Pb+² presentes em uma solução hidropônica pela macrófita Pistia stratiotes viva, comum em lagoas e em lagos rasos dos estados do sul do Brasil. Realizou-se o experimento com espécimes saudáveis de Pistia stratiotes devidamente aclimatadas. Para o cultivo foram usados recipientes plásticos contendo 5 L da solução hidropônica e 2 mg L-1 de Pb durante 35 dias em estufa. Vinte e uma replicatas foram utilizadas no experimento, sendo em cada uma adicionada cerca de 30 g em biomassa úmida da planta previamente aclimatadas. A temperatura e o pH foram monitorados diariamente, além da adição de água deionizada para amenizar as perdas por evaporação. Durante cinco semanas foram realizadas sete coletas das triplicatas de amostras de planta e da solução de cultivo. As amostras de macrófitas, pesadas na montagem do experimento e após a coleta, foram secas em estufa a 80°C durante 72 horas tendo redução de massa em torno de 94%. Cerca de 0,5 g da matéria seca foi digerida em meio ácido e um padrão interno de Gálio foi adicionado as amostras de solução de cultivo ou da planta digerida. Uma alíquota de 5µL foi extraída e depositada na superfície de um disco em acrílico (ø30 mm, 3 mm espessura) sendo seca a temperatura ambiente. Amostras de controle do branco, água deionizada e todos os reagentes usados no experimento foram preparados pelo mesmo procedimento. As concentrações presentes na solução de cultivo e na planta foram medidas pela técnica SR- TXRF. Os dados experimentais da cinética de remoção foram representados pelos modelos cinéticos de Langmuir irreversível, Langmuir reversível, Primeira ordem e Segunda ordem. A capacidade máxima de remoção (qmax) e a constante cinética de bioacumulação (k) foram os parâmetros ajustáveis. O modelo que descreveu de modo mais apropriado a bioacumulação foi o da cinética de Langmuir reversível, apresentando um qmax de 0,21 mg g-1 e k de 0,69 L mg-1 d-1, o que demonstra uma boa remoção de Pb+2 ao longo do tempo.
439

Estudo do potencial de biossorção dos íons Cd (II), Cu (II) e Zn (II) pela macrófita Eichhornia crassipes / Biosorption potential study of Cd (II), Cu (II) and Zn (II) by the macrophyte Eichhornia crassipes

Lavarda, Fábio Luciano 19 February 2010 (has links)
Made available in DSpace on 2017-07-10T18:08:13Z (GMT). No. of bitstreams: 1 Fabio Luciano Lavarda.pdf: 1286405 bytes, checksum: 6e333d013ea649c1abc83af92614fc90 (MD5) Previous issue date: 2010-02-19 / The aim of this work was to evaluate the adsorption capacity of Eichhornia crassipes as well as to investigate on the adsorption equilibrium and kinetic of copper, cadmium and zinc divalent ions in single, binary and ternary sorption systems. In order to improve the biosorption kinetic and experimental equilibrium conditions, the temperature effect on the plant drying was tested in 30 and 50°C temperatures, while the solution temperature effect was evaluated at four controlled temperatures, ranging from 25 to 45°C. The biosorbent grain size effect was also studied, using three fractional grain sizes between 0.147 to 0.589 mm and their mixture as well. For all tests, a volume of 50 mL for metal solution (4 mEq.L-1) was added to 250 mg dry plant in 125-mL Erlenmeyer flask. The mixtures were shaken for 12 h for each temperature setting, and then, the quantity of metal in each filtrated liquid phase sample was measured by AAS. In order to obtain the equilibrium time, the adsorption experimental times were set up at several short contact times, ranging from 5 min to 48 h. On the other hand, several batch single metal sorption experiments using the E. crassipes biomass as biosorbent were also carried out using a constant volume of 50 mL metal-supplied solution (4.0 mEq.L-1) in contact with dry biomass, ranging from 20 to 550 mg. Similarly, batch multicomponent sorption experiments, with equals and different amounts of metals spiked in biosorption medium, were performed in pH 5, during a 4 h shaking time. Within the dry temperature range tested, a higher metal removal performance was achieved for a temperature of 30oC. In the interval from 25 to 45oC controlled temperatures, the highest metal removal percent was observed to occur at 30oC solution temperature. On the other hand, the metal-sorption experiments based on fractional biomass grain sizes (0.147-0.589 mm) have not shown significant differences on the metal ion removal as compared among a mixture of them and different grain sizes tested. The results of monocomponent kinetic tests have showed that the equilibrium time was achieved around 2 h, 1 h and 45 min for Zn(II), Cu(II) and Cd(II), respectively. However, 1 and 2 h equilibrium time was achieved for Zn(II) and Cd(II), respectively, in a Zn(II)-Cd(II) binary system. In similar way, 1 and 2 h equilibrium time was achieved for Cu(II) and Cd(II), respectively, in a Cu(II)-Cd(II) binary system, while it was 45 min for both Zn(II) and Cu(II) in a Zn(II)-Cu(II) binary system. From the ternary kinetic test, equilibrium time of 45 min was observed for both Zn(II) and Cd(II), while a 1h equilibrium time was observed for Cu(II). The kinetic experimental data, at 30oC and pH 5, were found to best follow the pseudo-second order kinetic model, according to the good correlation coefficient value. The single equilibrium data for each metal at pH 5 were described according to the Langmuir isotherm model, with the same maximum metal content (qmax) values around 0.6 mEq.g-1 for all metals. While, the binary sorption data were evaluated through the Langmuir-type isotherms surface and their adjustable parameters were determined by the PSO (Particle Swarm Optimization) method. From the modeling results of the binary sorption data, the maximum metal contents were: 0.49 and 0.21 mEq.g-1 for Zn(II) and Cu(II), respectively, in Zn(II)-Cu(II) system; 0.42 and 0.17 mEq.g-1 for Cu(II) and Cd(II), respectively, in Cu(II)-Cd(II) system; 0.46 and 0.17 mEq.g-1 for Zn(II) and Cd(II), respectively, in Zn(II)-Cd(II) system. While, the maximum metal content values of 0.27, 0.65 and 0.30 mEq.g-1 were obtained for Zn(II), Cu(II) and Cd(II) ions, respectively, for a ternary sorption system. The kinetic and equilibrium adsorption results suggest that the E. crassipes biomass can be used as a low-cost, alternative biosorbent in metal treatment systems of industrial effluents. / O objetivo deste trabalho foi avaliar a capacidade de adsorção da macrófita Eichhornia crassipes, bem como investigar o equilíbrio e a cinética de adsorção dos íons divalentes cobre, cádmio e zinco, em sistemas monocomponentes, binários e ternários de sorção. A fim de melhorar a cinética de biossorção e as condições experimentais de equilíbrio, foi testado o efeito da temperatura de secagem da planta utilizando as temperaturas de 30 e 50°C, enquanto que o efeito da temperatura de sorção foi avaliada em quatro diferentes temperaturas, variando de 25 a 45°C. O efeito do tamanho dos grânulos do biossorvente também foi estudado utilizando-se três granulometrias, as quais estavam na faixa entre 0,147 e 0,589 mm e também foi testada a mistura dos grânulos sem ser peneirada. Para todos os testes, um volume de 50 mL de solução contendo os íons metálicos (4 mEq.L-1) foi colocada em contato com 250 mg de biomassa em erlenmeyers de 125 mL. As misturas foram agitadas por 12 h para cada ajuste de temperatura e, em seguida, as amostras foram filtradas e as quantidades de íons metálicos presentes na fase líquida foram medidas por espectrofotometria de absorção atômica. A fim de obter os tempos de equilíbrio foram realizados experimentos de adsorção em uma faixa de tempo variando de 5 min a 48 h. Também foram realizados testes batelada dos dados de equilíbrio utilizando a biomassa da E. crassipes como biossorvente em um volume constante de 50 mL de solução de metal (4,0 mEq.L-1) em contato com a biomassa seca, variando de 20 a 550 mg. Da mesma forma foram realizadas as bateladas experimentais de adsorção multicomponente, em pH 5, durante 4 horas de agitação. A temperatura de secagem da macrófita que obteve um desempenho maior na remoção dos íons metálicos foi a de 30°C. Para as temperaturas de sorção testadas no intervalo de 25 a 45°C, a percentagem mais elevada de remoção dos metais foi observada em 30°C. Por outro lado, os experimentos de sorção em várias granulometrias (0,147 a 0,589 mm) não mostraram diferenças significativas na remoção dos íons metálicos em relação à mistura delas ou entre as diferentes granulometrias testadas. Os resultados dos testes cinéticos monocomponentes mostraram que o tempo de equilíbrio foi alcançado em torno de 2 h, 1 h e 45 min para Zn (II), Cu (II) e Cd (II), respectivamente. No entanto, no sistema binário Zn(II)-Cd(II), os tempos de equilíbrio foram 1 e 2 h para o Zn(II) e para o Cd(II), respectivamente. De maneira similar, tempos de equilíbrio de 1 e 2 h também foram alcançados para o Cu(II) e para o Cd(II), respectivamente, no sistema binário Cu(II)-Cd(II) e de 45 min para ambos os íons Zn(II) e Cu(II) no sistema binário Zn(II)-Cu(II). A partir do teste cinético ternário foi possível observar que o tempo de equilíbrio para os íons Zn(II) e Cd(II) foram de 45 min, enquanto que para o Cu(II) o tempo de equilíbrio foi de 1h. Os dados experimentais da cinética em 30°C e em pH 5 foram melhor ajustados pelo modelo cinético de pseudo-segunda ordem de acordo com o valor do coeficiente de correlação obtido. Os dados de equilíbrio foram melhor descritos pela isoterma de Langmuir em pH 5 para todos os íons metálicos, obtendo os valores das capacidades máximas de sorção (qmax) em torno de 0,6 mEq.g-1 para todos os metais. Os dados de sorção para os sistemas binários foram avaliados através das isotermas de superfície de resposta pelo modelo de Langmuir e os parâmetros ajustáveis foram determinados pelo método PSO (Particle Swarm Optimization). A partir dos resultados obtidos na modelagem dos dados binários as capacidades máximas de sorção dos íons metálicos foram: 0,49 e 0,21 mEq.g-1 para o Zn(II) e o Cu(II), respectivamente, no sistema binário Zn(II)-Cu(II); 0,42 e 0,17 mEq.g-1 para o Cu(II) e o Cd(II), respectivamente, no sistema Cu(II)-Cd(II) e 0,46 e 0,17 mEq.g-1 para o Zn(II) e o Cd(II), respectivamente, no sistema Zn(II)-Cd(II). Enquanto que, para os sistema ternário, as capacidades máximas de sorção foram de 0,27; 0,65 e 0,30 mEq.g-1 para o Zn(II), o Cu(II) e o Cd(II), respectivamente. Os resultados obtidos na cinética de adsorção e de equilíbrio sugerem que a biomassa da E. crassipes pode ser utilizada com um baixo custo e é um biossorvente alternativo para o uso em sistemas de tratamento de efluentes industriais.
440

Estudo da especiação do cromo no processo de adsorção por carvão ativado usando a espectroscopia de emissão de raios X K&#946; / Study of the chromium speciation during the adsorption process on activated carbon as assessed by X-ray K&#946; emission spectroscopy

Camera, Adriana Simane 25 February 2011 (has links)
Made available in DSpace on 2017-07-10T18:08:16Z (GMT). No. of bitstreams: 1 Adriana Simane Camera.pdf: 3567207 bytes, checksum: 8d7a8eda99ee4c4d490c232bcc95cfd2 (MD5) Previous issue date: 2011-02-25 / Fundação Araucária / This work aims to study the reduction of hexavalent chromium to trivalent form through the adsorption process as assessed by the K&#946; X-ray emission spectrometry. As adsorbent material activated carbon samples were used, while the resin Amberlite IR 120 was used as an indicator of the presence of Cr(III) in all solutions containing Cr(VI). Preliminar speciation tests were performed previously in solutions containing Cr(VI) in order to analyze the possible reduction to Cr(III) due to the effect of solution pH. A EDTA-based colorimetric speciation method of Cr(III) was applied. Preliminary kinetic Cr adsorption tests were performed at controlled temperature and agitation, achieving the equilibrium at 24 h for activated carbon. Batch single equilibrium Cr adsorption experiments using activated carbon and cation exchange resin materials as adsorbents and 8 mequiv.L-1 of Cr (III) and Cr(VI) ions as adsorvates were performed at pH 3.5 and under controlled temperature and agitation. Adsorbent and Cr reference material samples were pressed in pellets for spectrometric analysis. By using a high-resolution spectrometer of Johann type and a 6.1 keV monochromatic X-ray beam, K&#946; X-ray emission spectra of Cr-treated adsorbent and reference material samples were registered by a Si detector, scanning the scattering X-ray by a spherycal bent analyzer around the K&#946;1,3 spectral line of metallic chromium. The sample, spherical bent analyzer and detector system was positioned on the Rowland circle in order to scan in high resolution condition, focus the maximum back-scattered X-ray beam on the main detector and built K&#946; X-ray emission spectra. As the incident monochromatic X-ray beam is a time-depending function, X-ray intensity that was registrated by detector was monitored and it was normalized to monitor-detector intensity. By setting measurement time of 2-4 h for Cr-treated adsorbent samples and 10-30 min for Cr reference material ones, a complete full scan of K&#946; X-ray emission region was performed with enough statistic to observe the sattelite lines of chromium, which suffer a strong influence due to the oxidation state of metal ion and the chemical environment. The Cr-K&#946; emission spectra were plotted on the basis of recorded X-ray intensity (y-axis) and spherical bent analyzer (SBA) position (x-axis), performing both the monitor-to-normalized intensity and the converted-to-energy SBA position. Besides this, scattered X-rays on matrix bulk and chromium absorption edge effect were systematically subtracted from Cr-K&#946; emission spectra, applying pseudo-physical procedures and consequentely allowing enhancing the weaker sattellites lines of chromium. Main physical characteristic such as energy and intensity of main (Cr-K&#946;1,3) and satellite lines (Cr-K&#946;2,5 and Cr-K&#946; ) for Cr-K&#946; emission spectra of Cr treated-adsorbent samples were extracted by gaussian type peak fits and then compared with those of Cr reference materials, allowing to assign the oxidation state of chromium ions adsorbed on activated carbon surface and removed by an ion exchange process on cationic resin surface. In addition, no Cr(VI) reduction in acidic solutions was observed according to the EDTA-based colorimetric speciation result as well as with no presence of Cr(III)-K&#946; spectral line pattern in Cr(VI) treated cationic resin samples. Based on Cr-K&#946; spectral line analysis, the activated carbon samples treated with Cr(III) and Cr(VI) ions have shown the same spectral line pattern corresponding to the Cr(III) one. Thus, the reduction of Cr(VI) to Cr(III) has occurred by the adsorption process / Este trabalho visa estudar a redução do cromo hexavalente à forma trivalente através do processo de adsorção, avaliada pela espectrometria K&#946; de emissão. Amostras de carvão ativado foram utilizados como material adsorvente, enquanto a resina Amberlite IR 120 foi usada como um indicador da presença de Cr(III) em todas as soluções contendo Cr(VI). Testes preliminares de especiação foram realizados em soluções contendo Cr(VI), a fim de analisar a possível redução para Cr(III) devido ao efeito do pH da solução. Foi aplicado o método de especiação colorimétrica de Cr(III), usando como complexante o EDTA. Testes preliminares da cinética de adsorção de íons de Cr foram realizados em batelada a temperatura e agitação controlada, alcançando o equilíbrio em 24 h para o carvão ativado. Foram realizados experimentos de adsorção de Cr utilizando carvão ativado e resina de troca catiônica materiais em soluções contendo 8 mequiv L-1 de Cr(III) e Cr(VI) em pH 3,5 e com temperatura e agitação controladas. Foram prensados, em forma de pastilhas, amostras de adsorventes tratados com Cr(III) e (VI), além de materiais de referência de Cr, para análise espectrométrica. Usando um espectrômetro de alta resolução do tipo de Johann e um feixe de raios X monocromático de 6,1 keV, foram registrados, por um detector de Si, espectros de emissão de raios-X K&#946; de amostras de material adsorbente tratados com íons de Cr bem como de materiais de referência, fazendo para tanto a varredura em energia dos raios-X espalhados pela amostra em torno da linha espectral principal K&#946; do cromo metálico. O conjunto amostra, analisador esfericamente curvado (SBA) e detector foi posicionado sobre um círculo de Rowland, a fim de obter, em condições de alta resolução, a focalização do feixe de raios X retro-espalhados no detector principal e permitindo a construção de espectros de emissão K&#946;. Como a intensidade do feixe incidente de raios-X monocromático foi uma função dependente do tempo, a intensidade de raios-X registrada pelo detector foi monitorada e normalizada por aquela registrada pelo detector-monitor. Ao definir o tempo de medição de 2-4 h para amostras adsorvente tratadas com íons de Cr e 10-30 min para os compostos de referência de Cr, uma região completa do espectro de emissão de raios-X foi obtida com estatística suficiente para observar as linhas satélite dos íons de cromo, que sofrem uma forte influência devido ao estado de oxidação do íon metálico e do ambiente químico. Os espectros K&#946; foram graficados em intensidade de raios-X contra a posição do analisador curvado (SBA), sendo sistematicamente normalizados a intensidade do detector-monitor e convertendo a posição do SBA em energia. Além disso, o fundo oriundo dos raios X espalhados na amostra e do efeito da borda de absorção do Cr foi subtraído de todos os espectros de emissão Cr-K, destacando assim as linhas satelites de cromo. As características físicas, como a energia e a intensidade, das linhas principais (Cr-K&#946;1,3) e linhas satélite (Cr-K&#946;2,5 e Cr-K&#946;") foram extraídas dos espectros de emissão Cr-K das amostras tratadas com Cr e comparados com os dos materiais de referência, permitindo inferir o estado de oxidação do cromo adsorvido no carvão ativado e os que também foram removidos pela resina catiônica. Além disso, não foi observado a redução do Cr(VI) na solução, de acordo com a ausência das linhas espectrais de Cr(III) em amostras de resina catiônica tratadas com Cr(VI). Baseado na análise das linhas espectrais, as amostras de carvão ativado tratadas com Cr(III) e Cr(VI) têm mostrado o mesmo padrão de linhas espectrais correspondentes ao Cr(III) e portanto, a redução de Cr(VI) para Cr(III) ocorreu durante o processo de adsorção

Page generated in 0.0365 seconds