• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 74
  • 1
  • Tagged with
  • 76
  • 36
  • 22
  • 20
  • 19
  • 15
  • 14
  • 13
  • 12
  • 11
  • 11
  • 10
  • 9
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Influência de agentes clareadores na rugosidade de compósitos dentários / Influence of bleaching gels on roughness of dental composites

Eduardo Varanda 18 December 2009 (has links)
O clareamento dental é o meio disponível mais simples, comum e conservador para o cirurgião-dentista proporcionar aos pacientes o padrão de cor de seus dentes mais desejado. Em alguns casos, os dentes que vão ser clareados podem apresentar restaurações realizadas com compósitos dentais, que são mais suscetíveis a alterações químicas, quando comparados a outros materiais restauradores. Alguns estudos mostraram que diferentes concentrações de agentes clareadores levaram a um aumento significativo da rugosidade superficial e das porosidades em compósitos dentais. Este estudo avaliou o efeito de dois agentes clareadores (Whiteness HP Blue 20%, Whiteness HP Max) sobre a rugosidade superficial de dois compósitos dentais, um micro-híbrido (Esthet X, Denstply) e outro nanoparticulado (Z 350, 3M ESPE). Um total de oito corpos de prova (9 x 2 mm) foram confeccionados com auxílio de uma matriz de teflon, sendo divididos em 4 grupos (Esthet X + Whiteness HP Blue 20%; Esthet X + Whiteness HP Max; Z 350 + Whiteness HP Blue 20%; Z 350 + Whiteness HP Max), sendo n=2. Os corpos de prova foram armazenados em saliva artificial neutra e, após 24 horas, foram polidos com discos de óxido de Alumínio (Sof-lex, 3M ESPE). Após sete dias de imersão salivar, cada corpo de prova foi levado a um microscópio de força atômica para obtenção do valor inicial de rugosidade superficial (Ra em nm). Em seguida, sem remover o corpo de prova do microscópio, o agente clareador foi aplicado sobre a superfície do corpo de prova, segundo as instruções do fabricante, de modo que permitisse uma posterior observação da mesma área do corpo de prova observada inicialmente, para obtenção do valor final de rugosidade superficial. Imagens em duas e três dimensões foram obtidas de cada corpo de prova para observação de alterações da topografia. Os resultados foram tratados estatisticamente por ANOVA e pelo teste de contraste Student-Newman-Keuls (p < 0,05). Não houve alteração significativa na rugosidade superficial (Ra) dos corpos da prova de compósitos micro-híbrido e nanoparticulado, submetidos aos agentes clareadores Whiteness HP Blue 20% e Whiteness HP Maxx. No entanto, independente do agente clareador utilizado, foram observadas maiores alterações topográficas nas imagens de microscopia de força atômica da superfície do compósito micro-híbrido do que nas imagens do nanoparticulado. / Dental bleaching is the simplest, the most common and conservative available way for dentists to offer their patients the standard color of teeth more desired. In some cases, the teeth that will be bleached may include restorations made of resin composites, which are more prone to chemical alteration compared with other restoration materials. Some studies have showed that different concentrations of bleaching gels might lead to a significant increase in surface roughness and amount of porosities in composite resins. This study evaluated the effect of two bleaching gels (Whiteness HP Blue 20%, Whiteness HP Max) on surface roughness of two resin composites, micro-hybrid (Esthet X, Denstply) and nanoparticled (Z350, 3M ESPE). A total of eight specimens (9 x 2 mm) were produced with a Teflon mold help, and were divided into four groups (Esthet X + Whiteness HP Blue 20%; Esthet X + Whiteness HP Max; Z 350 + Whiteness HP Blue 20%; Z 350 + Whiteness HP Max), with n=2. They were stored in neutral artificial saliva and, after 24 hours, were polished with aluminium oxide discs (Sof-lex, 3M ESPE). After seven days of salivary immersion, each specimen was taken to an atomic force microscope for recording initial value of surface roughness (Ra in nm). After that procedure, without removing the specimen from microscope, the bleaching gel was applied on the surface of the specimen, following manufacturers instructions, in order to allow posterior observation of the same area of the specimen initially observed, for recording the final value of surface roughness. Two-dimensional and 3D images were taken from each specimen group for observation of surface alterations. The results were statistically analyzed by ANOVA and the SNK test (p< 0.05). There were no statistically significant differences in the surface roughness (Ra) for specimens of micro-hybrid and nanoparticled composites, submitted to the bleaching agents Whiteness HP Blue 20% and Whiteness HP Maxx. However, there were noticed larger surface alterations in atomic force microscope images on the surface of micro-hybrid composites than on the nanoparticled, independently of the bleaching agent used.
42

Capturando estados ligados no contínuo de átomos fantasmas no grafeno / Catching the bound states in the continuum of a phantom atom in graphene

Marques, Yuri Policei [UNESP] 16 February 2016 (has links)
Submitted by YURI POLICEI MARQUES null (yurimarques111@gmail.com) on 2016-03-16T13:32:59Z No. of bitstreams: 1 Thesis_Yuri.pdf: 5717547 bytes, checksum: 01fcb3125bd18e6cdbca67bc795b6088 (MD5) / Approved for entry into archive by Sandra Manzano de Almeida (smanzano@marilia.unesp.br) on 2016-03-16T18:19:59Z (GMT) No. of bitstreams: 1 marques_yp_me_ilha.pdf: 5717547 bytes, checksum: 01fcb3125bd18e6cdbca67bc795b6088 (MD5) / Made available in DSpace on 2016-03-16T18:19:59Z (GMT). No. of bitstreams: 1 marques_yp_me_ilha.pdf: 5717547 bytes, checksum: 01fcb3125bd18e6cdbca67bc795b6088 (MD5) Previous issue date: 2016-02-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Exploramos teoricamente a emergência de estados ligados no contínuo (BICs: bound states in the continuum) em um sistema formado por duas impurezas situadas em lados opostos da folha de grafeno e colineares com o centro da célula hexagonal, onde ambas impurezas estão acopladas aos seis carbonos desta mesma célula, ou ainda acopladas a apenas um átomo fantasma, localizado no centro da célula, que simula os seis carbonos. Verificamos que nesta configuração a densidade local de estados, perto dos pontos de Dirac, exibe aspectos característicos: i) uma densidade de estados com dependência cúbica na energia em vez da dependência linear do grafeno puro, assim como encontrado no New J. Phys. 16, 013045 (2014) e ii) a formação de BICs como consequência de uma interferência Fano destrutiva assistida por uma correlação de Coulomb nas impurezas. Para a geometria em que as impurezas estão colineares com um átomo de carbono, observamos ausência de BICs. / We explore theoretically the formation of bound states in the continuum (BICs) in graphene hosting two collinear adatoms situated at different sides of the sheet and at the center of the hexagonal cell, where a phantom atom of a fictitious lattice emulates the six carbons of the cell. We verify that in this configuration the local density of states (LDOS) near the Dirac points exhibits two characteristic features: i) the cubic dependence on energy instead of the linear one for graphene as found in New J. Phys. 16, 013045 (2014) and ii) formation of BICs as aftermath of a Fano destructive interference assisted by the Coulomb correlations in the adatoms. For the geometry where adatoms are collinear to carbon atoms, we report absence of BICs.
43

Caracterização termo-óptica quantitativa de fibras de poliéster e seus compósitos com polietileno

Bicalho, Luciana Assumpção 08 March 2015 (has links)
Submitted by Izabel Franco (izabel-franco@ufscar.br) on 2016-09-13T18:29:41Z No. of bitstreams: 1 DissLAB.pdf: 3781531 bytes, checksum: fcc30c9bb1613708fbf75894ef5ad460 (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-09-15T13:38:04Z (GMT) No. of bitstreams: 1 DissLAB.pdf: 3781531 bytes, checksum: fcc30c9bb1613708fbf75894ef5ad460 (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-09-15T13:38:10Z (GMT) No. of bitstreams: 1 DissLAB.pdf: 3781531 bytes, checksum: fcc30c9bb1613708fbf75894ef5ad460 (MD5) / Made available in DSpace on 2016-09-15T13:38:16Z (GMT). No. of bitstreams: 1 DissLAB.pdf: 3781531 bytes, checksum: fcc30c9bb1613708fbf75894ef5ad460 (MD5) Previous issue date: 2015-03-08 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / The work herein aims at investigating the thermo-optical behavior of polyethylene terephthalate and its composites with polyethylene, in real time, by means of an optical module recently developed in our research group. Polyethylene terephthalate was the material of choice because of its various thermal transitions and optical properties. Multilayered films comprising fibers of polyethylene terephthalate sandwiched with polyethylene films were prepared to study the influence of a matrix on the fibers thermo-optical responses. This was investigated by coupling a hot-stage onto a stand-up optical microscopy and placing the optical module into the analyzer slot. The module encompasses adjacent photocells with/without analyzer to read both turbidity (resulting from scattered light) and depolarized light intensity due to crystallites. In order to handling the signal a software was developed in LabView 8.6 platform from National Instruments for data collection, real-time calculation, screen presentation and data saving. In addition, all parameters set on the CSS 450 can be controlled via software. Finally, a digital camera was coupled on the top of the microscope (ocular tube) to allow for both image capturing and video recording. The structural changes arising from the thermal protocol were assessed following the elicited responses present at the depolarized light intensity and turbidity. Both optical phenomena were sensitive to polymer thermal transitions such as glass transition and melting temperature. The photocell with analyzer is able to collect the thermal transitions and the cold crystallization typical of polyethylene terephthalate resin. The introduction of the optical path difference, an alternative way of displaying the optical data as function temperature, makes easier the understanding of molecule mobility, cold crystallization and melting. The narrow relation existent between the optical behavior and that obtained from the differential scanning calorimetry measurements leaded to the validation of the thermo-optical method, which has the advantage to provide additional information on the fiber orientation and stretching. / Utilizou-se um sistema de caracterização qualitativa e quantitativa em tempo real do comportamento termo-óptico de fibras poliméricas de polietileno tereftalato (PET) e seus compósitos com polietileno desenvolvido pelo grupo de pesquisa. Ele permite caracterizar suas principias transições térmicas (Tg, cristalização a frio, Tm e Tc) e particularmente a birrefringência, que é fortemente dependente do nível de orientação molecular e da temperatura. O dispositivo termo-óptico foi acoplado a um microscópio óptico de luz polarizada (MOLP) com estágio a quente (Linkam). Esse consiste em um módulo com dois fotodetectores a ser instalado na fenda usada para a inserção do analisador, sendo assim posicionado no caminho óptico do microscópio. Isto permite quantificar a intensidade de luz transmitida, i.e. turbidez e a intensidade de luz transmitida com polarização cruzada, i.e. diferença de caminho óptico OPD e por conseguinte a birrefringência das fibras e de seus compósitos. Tal metodologia permite a captação simultânea dos sinais ópticos e das imagens das amostras durante o aquecimento, passando pelas suas transições térmicas. Todo o sistema é controlado por um programa computacional, especialmente desenvolvido em plataforma LabView8.6, permitindo a gravação simultânea das imagens e dos sinais ópticos. A turbidez se mostrou sensível para a caracterização das temperaturas de fusão. Através da análise simultânea da intensidade de luz transmitida com polarização cruzada das fibras de PET e sua cor comparada á Carta de Cores de Michel-Lévy permitiu a caraterização quantitativa do nível de estiramento molecular das fibras de PET e sua orientação macroscópica nos compósitos. Como técnica padrão utilizou-se a Calorimetria Exploratória Diferencial, que mostrou haver uma boa correlação entre os resultados observados pelas duas técnicas.
44

Capturando estados ligados no contínuo de átomos fantasmas no grafeno /

Marques, Yuri Policei. January 2016 (has links)
Orientador: Antonio Carlos Ferreira Seridonio / Resumo: Exploramos teoricamente a emergência de estados ligados no contínuo (BICs: bound states in the continuum) em um sistema formado por duas impurezas situadas em lados opostos da folha de grafeno e colineares com o centro da célula hexagonal, onde ambas impurezas estão acopladas aos seis carbonos desta mesma célula, ou ainda acopladas a apenas um átomo fantasma, localizado no centro da célula, que simula os seis carbonos. Verificamos que nesta configuração a densidade local de estados, perto dos pontos de Dirac, exibe aspectos característicos: i) uma densidade de estados com dependência cúbica na energia em vez da dependência linear do grafeno puro, assim como encontrado no New J. Phys. 16, 013045 (2014) e ii) a formação de BICs como consequência de uma interferência Fano destrutiva assistida por uma correlação de Coulomb nas impurezas. Para a geometria em que as impurezas estão colineares com um átomo de carbono, observamos ausência de BICs. / Abstract: We explore theoretically the formation of bound states in the continuum (BICs) in graphene hosting two collinear adatoms situated at different sides of the sheet and at the center of the hexagonal cell, where a phantom atom of a fictitious lattice emulates the six carbons of the cell. We verify that in this configuration the local density of states(LDOS) near the Dirac points exhibits two characteristic features: i) the cubic dependence on energy instead of the linear one for graphene as found in New J. Phys. 16, 013045 (2014) and ii) formation of BICs as aftermath of a Fano destructive interference assisted by the Coulomb correlations in the adatoms. For the geometry where adatoms are collinear to carbon atoms, we report absence of BICs. / Mestre
45

Influência de agentes clareadores na rugosidade de compósitos dentários / Influence of bleaching gels on roughness of dental composites

Eduardo Varanda 18 December 2009 (has links)
O clareamento dental é o meio disponível mais simples, comum e conservador para o cirurgião-dentista proporcionar aos pacientes o padrão de cor de seus dentes mais desejado. Em alguns casos, os dentes que vão ser clareados podem apresentar restaurações realizadas com compósitos dentais, que são mais suscetíveis a alterações químicas, quando comparados a outros materiais restauradores. Alguns estudos mostraram que diferentes concentrações de agentes clareadores levaram a um aumento significativo da rugosidade superficial e das porosidades em compósitos dentais. Este estudo avaliou o efeito de dois agentes clareadores (Whiteness HP Blue 20%, Whiteness HP Max) sobre a rugosidade superficial de dois compósitos dentais, um micro-híbrido (Esthet X, Denstply) e outro nanoparticulado (Z 350, 3M ESPE). Um total de oito corpos de prova (9 x 2 mm) foram confeccionados com auxílio de uma matriz de teflon, sendo divididos em 4 grupos (Esthet X + Whiteness HP Blue 20%; Esthet X + Whiteness HP Max; Z 350 + Whiteness HP Blue 20%; Z 350 + Whiteness HP Max), sendo n=2. Os corpos de prova foram armazenados em saliva artificial neutra e, após 24 horas, foram polidos com discos de óxido de Alumínio (Sof-lex, 3M ESPE). Após sete dias de imersão salivar, cada corpo de prova foi levado a um microscópio de força atômica para obtenção do valor inicial de rugosidade superficial (Ra em nm). Em seguida, sem remover o corpo de prova do microscópio, o agente clareador foi aplicado sobre a superfície do corpo de prova, segundo as instruções do fabricante, de modo que permitisse uma posterior observação da mesma área do corpo de prova observada inicialmente, para obtenção do valor final de rugosidade superficial. Imagens em duas e três dimensões foram obtidas de cada corpo de prova para observação de alterações da topografia. Os resultados foram tratados estatisticamente por ANOVA e pelo teste de contraste Student-Newman-Keuls (p < 0,05). Não houve alteração significativa na rugosidade superficial (Ra) dos corpos da prova de compósitos micro-híbrido e nanoparticulado, submetidos aos agentes clareadores Whiteness HP Blue 20% e Whiteness HP Maxx. No entanto, independente do agente clareador utilizado, foram observadas maiores alterações topográficas nas imagens de microscopia de força atômica da superfície do compósito micro-híbrido do que nas imagens do nanoparticulado. / Dental bleaching is the simplest, the most common and conservative available way for dentists to offer their patients the standard color of teeth more desired. In some cases, the teeth that will be bleached may include restorations made of resin composites, which are more prone to chemical alteration compared with other restoration materials. Some studies have showed that different concentrations of bleaching gels might lead to a significant increase in surface roughness and amount of porosities in composite resins. This study evaluated the effect of two bleaching gels (Whiteness HP Blue 20%, Whiteness HP Max) on surface roughness of two resin composites, micro-hybrid (Esthet X, Denstply) and nanoparticled (Z350, 3M ESPE). A total of eight specimens (9 x 2 mm) were produced with a Teflon mold help, and were divided into four groups (Esthet X + Whiteness HP Blue 20%; Esthet X + Whiteness HP Max; Z 350 + Whiteness HP Blue 20%; Z 350 + Whiteness HP Max), with n=2. They were stored in neutral artificial saliva and, after 24 hours, were polished with aluminium oxide discs (Sof-lex, 3M ESPE). After seven days of salivary immersion, each specimen was taken to an atomic force microscope for recording initial value of surface roughness (Ra in nm). After that procedure, without removing the specimen from microscope, the bleaching gel was applied on the surface of the specimen, following manufacturers instructions, in order to allow posterior observation of the same area of the specimen initially observed, for recording the final value of surface roughness. Two-dimensional and 3D images were taken from each specimen group for observation of surface alterations. The results were statistically analyzed by ANOVA and the SNK test (p< 0.05). There were no statistically significant differences in the surface roughness (Ra) for specimens of micro-hybrid and nanoparticled composites, submitted to the bleaching agents Whiteness HP Blue 20% and Whiteness HP Maxx. However, there were noticed larger surface alterations in atomic force microscope images on the surface of micro-hybrid composites than on the nanoparticled, independently of the bleaching agent used.
46

Influência de escâneres CAD/CAM na adaptação marginal de infraestruturas em zircônia implanto-suportadas

Resende, Caio César Dias 15 February 2017 (has links)
CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / FAPEMIG - Fundação de Amparo a Pesquisa do Estado de Minas Gerais / 0 objetivo desse estudo foi comparar a adaptação marginal de infraestruturas em zircônia confeccionadas pelo sistema CAD/CAM, utilizando dois escâneres e uma única fresadora, por meio do microscópio eletrônico de varredura (MEV). Materiais e métodos: Dez infraestruturas aparafusadas, implanto-suportadas, de três elementos foram divididas em dois grupos para avaliara adaptação marginal no modelo boca. Dez infraestruturas em zircônia foram fabricadas por uma única fresadora, cinco foram obtidas por meio do escaneamento com o escâner 7series Dental Wings e cinco com o escâner Ceramill map 400. A desadaptação vertical e horizontal da interface protética (mesial e distai de todos os implantes) foram analisadas e mensuradas pelo MEV, resultando em trinta medidas por grupo (n=30). As medidas foram obtidas em duas situações, a primeira quando um parafuso central está posicionado e a segunda com todos os parafusos apertados. A análise estatística foi realizada utilizando o teste estatístico U Mann-Whitney (a=.05) para desadaptações verticais. Os valores de desadaptações horizontais foram divididos em três situações: sobre extensão, zero e sub extensão. Resultados: Diferença estatística significante foi encontrada entre os valores de desadaptação marginal quando todos os parafusos estavam apertados, porém todos esses valores estão abaixo de 16 pm. Cinco e Dezoito valores de desadaptação horizontal foram encontrados nos escâneres 7series Dental Wings e Ceramil map 400, respectivamente. Conclusão: O uso de diferentes escâneres apresenta influencia na adaptação final de infraestruturas. / The purpose of this study was to compare the fit accuracy of CAD/CAM- fabricated zirconia frameworks using two different scanners and the same milling unit by scanning electron microscopy (SEM). Material and methods. Ten 3-unit implant-supported, screw-retained frameworks were fabricated to fit a mastermodel. The same manufacturing milling unit fabricated all the frameworks using two scanners, five frameworks for each group: 7series Dental Wings and Ceramill map 400. The vertical and horizontal misfit at the implant-framework interface (mesial and distal of all implants) were measured by SEM resulting in 30 measurements per group (n=30) when only 1 screw was tightened and after all screws were tightened. The statistical analysis was performed using Mann-Whitney test (a=.05) by vertical misfit. Horizontal misfit values were separated in three situations: underextension, zero and overextension. Results: Significant difference was found between the fit accuracy of the two groups when all screws were tightened, however all values is below 16 pm. Five and eighteen horizontal misfit were found in Dental Wings and Ceramill map 400, respectively. Conclusions: The use of different scanners have influence on fit accuracy of zirconia frameworks. / Dissertação (Mestrado)
47

Influência do efeito Kondo na condutância de contatos pontuais de superfícies metálicas. / The Kondo effect influence on the conductance of pontual contacts on metallic surfaces.

Antonio Carlos Ferreira Seridonio 05 April 2002 (has links)
A microscopia de varredura por tunelamento (MVT) é uma nova maneira de se observar experimentalmente o efeito Kondo. Quando uma concentração de átomos é adicionada a um meio metálico (metal hospedeiro), a corrente de tunelamento passa a depender de fatores de origem não geométrica. O rearranjo das cargas dentro do volume metálico (oscilações de Friedel) e o espalhamento de spins eletrônicos (efeito Kondo), devido a introdução de impurezas, mudam o valor da corrente e influenciam o levantamento da topografia do espécime examinado. Esses fatores devem ser considerados para que a topografia gerada seja condizente com a topografia verdadeira. Utilizamos como modelo teórico para descrição desse sistema, o modelo de Anderson de uma impureza para simular o espécime examinado e uma banda de condução livre para representar os elétrons da agulha metálica do microscópio. Nossa abordagem usa a fórmula de Kubo para o cálculo da corrente de tunelamento, supondo Hamiltoniano de tunelamento como perturbação e o potencial elétrico no regime linear. Apresentamos inicialmente um estudo para o Modelo do Nível Ressonante, isto é, o modelo de Anderson sem correlação, com o objetivo de demonstrar a precisão do método do Grupo de Renormalização Numérico. Em seguida, analisamos o Modelo de Anderson correlacionado. Os resultados tanto para a condutância em função da distância entre ponta e impureza a temperatura fixa, como para condutância em função da temperatura e distância fixa, permitem interpretação física transparente desde que levem em conta a ressonância de Kondo na densidade espectral. / The scanning tunneling microscopy (STM) is a new way to observe experimentally the Kondo effect. When a concentration of atoms id added to a sample (host metal), the tunneling current begins to depend on other non-geometric factors. The rearrangement of charges in the metallic bulk (Friedel oscillations) and the electronic spin scattering (Kondo effect), due to the presence of impurities, change the current value and affect the sample´s topography. These factors must be considered in order to make a correspondence between the generated topography with the true one. As a theoretical description of the system, we use the single impurity Anderson model to simulate the examined sample and a free conduction band to represent the electrons of the microscope metallic tip. Our treatment uses the Kubo formula to calculate the tunneling current, assuming the tunneling Hamiltonian as a perturbation and the electric potential in the linear regime. We initially present a study of the Resonant Level Model, i.e, the Anderson model without correlaction, to show the accuary of the Numerical Renormalization Group procedure. In the next step, we analyse the correlated Anderson model. The dependence of the conductance on tip-impurity distance, at constant temperature, and its dependence on temperature for constant tip-impurity distance, allow a clear physical interpretation after taking into account the Kondo resonance in the spectral density.
48

Avaliação in vitro da capacidade seladora e da qualidade da obturação de quatro cimentos endodônticos utilizando a técnica do cone único / In vitro evaluation of sealing-ability and obturation quality of four endodontic sealers using the single cone obturation technique

Pablo Andres Amoroso Silva 10 May 2013 (has links)
O objetivo deste trabalho foi avaliar o selamento apical em 7 e 30 dias de, obturações de canais radiculares com a técnica de cone único utilizando 4 cimentos endodônticos, AH Plus, MTA Fillapex, cimento Portland, e cimento experimental Sealepox, por meio do sistema de infiltração de fluidos FLODEC, e a qualidade de obturação, em microscopia confocal a laser, analisando o perímetro de penetração dos cimentos nos túbulos dentinários, e a porcentagem de fendas na interface cimento/dentina, e por meio de estereomicroscopia, a porcentagem de cimento, guta-percha e espaços vazios a 2,4 e 6mm do ápice radicular, dos cimentos. Sessenta e oito dentes unirradiculados, com canais únicos tiveram seus canais instrumentados e, então, obturados com os cimentos, previamente corados com Rodamina B. As amostras foram conservadas em meio úmido a 37º de temperatura. Após 7 dias, os dentes foram adaptados para os testes de infiltração de fluidos, fazendo-se as leituras durante 12 minutos constantes, para todos os espécimes. Trinta dias depois, as leituras foram realizadas novamente com os mesmos parâmetros anteriores. Todos os espécimes foram cortados em secções de 2mm de espessura nos níveis de 2,4 e 6mm do ápice radicular. Mediante estereomicroscopia, foram calculadas as porcentagens de cimento, guta-percha e espaços vazios, e em microscopia confocal, as porcentagens de fendas e o perímetro de penetração dos cimentos no interior dos túbulos dentinários, em todas as secções. Os resultados obtidos mostraram que, todos os cimentos permitiram a infiltração de fluidos em 7 dias, sendo que, o MTA Fillapex exibiu, significativamente, menor infiltração que os cimentos AH Plus e Portland. Em 30 dias não houve diferenças estatísticas entre os cimentos. Nas avaliações em microscopia confocal, observou-se a presença de fendas na interface dentina/cimento em todas as secções avaliadas. À estereomicroscopia observaram-se espaços vazios em todas as secções, bem como, variações nas porcentagens de cimento e guta-percha. / The aim of this study was to evaluate sealing-ability at 7 and 30 days of root canal obturations using a single cone obturation technique of 4 endodontic sealers, AH Plus, Mta Fillapex, Portland Cement and a experimental sealer Sealepox, using a fluid filtration recording device (FLODEC), to evaluate the obturation quality using confocal laser microscopy analyzing interfacial adaptation of sealer/dentin interface, perimeter of sealer penetration into dentinal tubules, and using stereomicroscopy, the percentage of sealer, guta-percha and voids at 2, 4 and 6mm from de apex. Sixtyeight single rooted teeth with one canal were instrumented and then, obturated, with the sealers, in which, Rodamine B was previously added. Samples were stored in 100% humidity and at 37º temperature. After 7 days, all the specimens were submitted to microleakage tests for a 12-minute period. Mta Fillapex showed the lowest leakage percentage when compared with AH Plus and Portland cement. 30 days after the first test, microleakage evaluations were repeated, and the results showed no statistical differences. Then, all samples were cut horizontally of 2mm of thickness at 2,4,6mm from the apex. Using estereomicrocopy, percentage of sealer, guta-percha and voids were measured, and using confocal laser microscopy percentages of interfacial adaptation and perimeter of sealer penetration into dentinal tubules were calculated. According to the results it was concluded that all sealers permitted fluid filtration at 7 and 30 days, being that, at 7 days, MTA Fillapex exhibited significantly, less fluid filtration than AH Plus and Portland Cement. At 30 days, no statistically differences were found. On confocal evaluations, it was observed the presence of gaps at the sealer/dentin interface in all evaluated sections. Stereomicroscopy assessments showed voids in all sections and as well variations on sealer and guta-percha percentages.
49

Compósito geopolimérico reforçado com tecido de juta

Portela, Gleicyanne Oliveira de Souza 01 April 2016 (has links)
Submitted by Adriely Bruce (adriely_bruce@hotmail.com) on 2016-12-02T14:22:37Z No. of bitstreams: 1 Dissertação - Gleicyanne O. S. Portela.pdf: 22271229 bytes, checksum: 080a862aceacc66dfad8d9ac34c508bf (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-12-02T19:19:50Z (GMT) No. of bitstreams: 1 Dissertação - Gleicyanne O. S. Portela.pdf: 22271229 bytes, checksum: 080a862aceacc66dfad8d9ac34c508bf (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-12-02T19:20:26Z (GMT) No. of bitstreams: 1 Dissertação - Gleicyanne O. S. Portela.pdf: 22271229 bytes, checksum: 080a862aceacc66dfad8d9ac34c508bf (MD5) / Made available in DSpace on 2016-12-02T19:20:26Z (GMT). No. of bitstreams: 1 Dissertação - Gleicyanne O. S. Portela.pdf: 22271229 bytes, checksum: 080a862aceacc66dfad8d9ac34c508bf (MD5) Previous issue date: 2016-04-01 / The usage of natural fibers as reinforcement in cementitious matrices has been an alternative to replacing the synthetic fibers. In this work jute fiber were characterized and added in composite. For the production of geopolymer, the activators were potassium hydroxide and potassium silicate hydroxide mixed with metakaolin, cement and sand. Characterization tests utilizing x-ray fluorescence techniques (XFR), X-ray diffractometry (XRD), chemical and physical tests, tensile and flexural tests and analyzis of the microstructu e by scanning electron microscopy (SEM) were performed for characterization of materials. Compressive strength tests on the matrix were performed at the ages of 7, 14 and 28 days, and the samples had a maximum performance of compressive strength at 58,29 MPa. The composites reinforced with three layers of jute fabric were submitted to mechanical tests after 14days and showed a flexural behavior with maximum stress of 21.4 MPa. The results indicated that the use of natural fibers increased mechanical performance of traction and flexion geopolymer composite. / O uso de fibras naturais como reforço em matrizes cimentícias tem sido uma alternativa para substituição das fibras sintéticas. Neste trabalho, as fibras de juta foram caracterizadas e adicionadas compósitos. Para a produção dos geopolímeros os ativadores foram o hidróxido de potássio e silicato de hidróxido de potássio, misturados a metacaulinita, cimento e areia. Ensaios de caracterização utilizando técnicas de Fluorescência de raio-x (FRX), Difratometria de raio-x (DRX), ensaios químicos e físicos, ensaios de tração e flexão e analise da microestrutura por microscopia eletrônica de varredura (MEV) foram realizados para a caracterização dos materiais. Os testes de resistência à compressão na matriz foram realizados nas idades de 7, 14 e 28 dias, amostras apresentaram desempenho máximo de resistência à compressão de 58,29 MPa. Os compósitos reforçados com três camadas de tecido de juta foram submetidos aos ensaios mecânicos após 14 dias e apresentaram comportamento à flexão com tensão máxima de 21,4 Mpa. Os resultados obtidos indicaram que o uso de fibras naturais aumentou o desempenho mecânico de tração e flexão do compósito geopolímero.
50

Sistema de micromanipulação e microanálise com pinças óticas / Micromanipulation and microanalysis in an optical tweezers systems

Fontes, Adriana 04 February 2004 (has links)
Orientador: Carlos Lenz Cesar / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica "Gleb Wataghin" / Made available in DSpace on 2018-08-04T14:59:07Z (GMT). No. of bitstreams: 1 Fontes_Adriana_D.pdf: 3876787 bytes, checksum: 3edd1575e993d4685d7e82c8a3f77cfb (MD5) Previous issue date: 2004 / Resumo: Não informado / Abstract: Not informed. / Doutorado / Física / Doutor em Ciências

Page generated in 0.0275 seconds