• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • 7
  • Tagged with
  • 27
  • 27
  • 27
  • 27
  • 15
  • 13
  • 9
  • 6
  • 6
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Nanolithographie par sonde locale catalytique : une approche bottom-up pour la nanostructuration de surfaces organominérales / Catalytic scanning probe lithography : a bottom-up approach allowing the nanostructuration of organomineral surfaces

Botton, Julien 17 December 2015 (has links)
Face à la quête constante de miniaturisation, les nanosciences ont connu un essor fulgurant lors de la dernière décennie. Au sein de ces dernières, les procédés lithographiques – clé de voûte de l’industrie des semi-conducteurs – permettent désormais d’accéder à des nanomatériaux fonctionnels. Malgré les récents développements technologiques, l’obtention de nanostructures possédant une résolution inférieure à 100 nm reste un défi majeur pour la communauté scientifique.Devant l’intérêt grandissant de développer des méthodes alternatives en nanolithographie, notre groupe s’est tourné vers une approche chimique, nommée nanolithographie par sonde locale catalytique (cSPL). Combinant la robustesse de la catalyse organométallique et la flexibilité offerte par la microscopie à sonde locale, notre stratégie permet la nanostructuration de surfaces organominérales par la création de liaisons covalentes dans des conditions douces. Cette approche innovante constitue le premier exemple d’immobilisation d’un catalyseur homogène à la surface d’une pointe d’un microscope à force atomique (AFM), dans l’optique de contrôler spatialement une réactivité chimique, l’époxydation localisée d’alcènes terminaux. Ces fonctions époxydes ont été employées comme points d’ancrage dans la nanostructuration à façon de surfaces de silicium avec une large variété de nucléophiles. De plus, l’optimisation des paramètres physico-chimique influant sur la réaction, a permis d’atteindre des résolutions latérales de l’ordre de 40 nm et laisse entrevoir de nombreuses perspectives dans la nanostructuration tridimensionnelle de matériaux organiques. / In regard to the constant quest for miniaturization, the field of nanosciences has known a tremendous expansion over the last decade. More precisely, lithographic technologies - key processes for the semi-conductor industry – allow to access to functional nanomaterials. Despite recent technological developments, the synthesis of nanostructures with a sub-100 nm resolution remains a major challenge for the scientific community.Due to the growing interest in the design of new nanolithographic methods, our group has focused its efforts on the development of a chemical approach, named catalytic scanning probe lithography (cSPL). Unifying the robustness of organometallic catalysis and the flexibility offered by scanning probe microscopy, our strategy allows the nanostructuration of organomineral surfaces in a soft controlled manner by the formation of covalent bonds. This innovative approach represents the first example of the immobilization of an homogeneous catalyst on the edge of an atomic force microscope (AFM) tip, in order to spatially control a chemical reaction: the localized epoxidation reaction of terminal alkenes. Those epoxides were then used as anchoring sites, in the nanostructuration of silicon wafers with a broad range of nucleophiles. Moreover, the different physico-chemical parameters influencing the reaction were optimized, allowing us to reach lateral resolutions down to 40 nm and opening new perspectives in the field of 3D-nanostructuration of organic materials.
12

Assemblages 2D de l'Annexine A5 : Applications biotechnologiques & Aspects fonctionnels

Berat, Rémi 12 December 2007 (has links) (PDF)
L'Annexine A5 (Anx5) est une protéine de la famille des annexines qui présente la propriété de s'organiser à la surface des bicouches lipidiques en trimères et en assemblages bidimensionnels (2D) de trimères. Ce travail de thèse concerne le développement d'applications biotechnologiques des assemblages 2D d'Anx5 ainsi qu'une étude des propriétés fonctionnelles de ces assemblages. Ces travaux ont été réalisés principalement à l'aide des méthodes de la microbalance à cristal de quartz avec mesure de dissipation (QCM-D) et de la microscopie à force atomique (AFM). <br />La première partie de cette thèse concerne le développement de plates-formes d'ancrage basées sur des assemblages 2D de protéines dérivées de l'Anx5. Des complexes covalents entre l'Anx5 et des peptides d'adhésion cellulaire pour la réalisation de plates-formes d'ancrage de cellules. Des protéines de fusion entre l'Anx5 et un fragment de la protéine A ont d'autre part servi au développement de plates-formes 2D pour l'immobilisation contrôlée d'anticorps et de protéines. <br />La seconde partie de cette thèse concerne l'étude des propriétés fonctionnelles des assemblages 2D d'Anx5. L'étude de l'interaction d'un anticorps anti-phospholipide avec les assemblages 2D d'Anx5 montre que cet anticorps ne perturbe pas l'organisation 2D de l'Anx5. La seconde étude concernant l'influence des assemblages 2D de l'Anx5 sur la dynamique des bicouches lipidiques établie une corrélation entre la formation de trimères et le ralentissement de la dynamique des membranes.<br />Ces travaux contribuent à notre compréhension des propriétés des assemblages 2D d'Anx5 et permettent d'envisager le développement de biocapteurs pour cellules ou molécules.
13

Restauration et séparation de signaux polynomiaux par morceaux. Application à la microscopie de force atomique

Duan, Junbo 15 November 2010 (has links) (PDF)
Cette thèse s'inscrit dans le domaine des problèmes inverses en traitement du signal. Elle est consacrée à la conception d'algorithmes de restauration et de séparation de signaux parcimonieux et à leur application à l'approximation de courbes de forces en microscopie de force atomique (AFM), où la notion de parcimonie est liée au nombre de points de discontinuité dans le signal (sauts, changements de pente, changements de courbure). Du point de vue méthodologique, des algorithmes sous-optimaux sont proposés pour le problème de l'approximation parcimonieuse basée sur la pseudo-norme ℓ0 : l'algorithme Single Best Replacement (SBR) est un algorithme itératif de type « ajout-retrait » inspiré d'algorithmes existants pour la restauration de signaux Bernoulli-Gaussiens. L'algorithme Continuation Single Best Replacement (CSBR) est un algorithme permettant de fournir des approximations à des degrés de parcimonie variables. Nous proposons aussi un algorithme de séparation de sources parcimonieuses à partir de mélanges avec retards, basé sur l'application préalable de l'algorithme CSBR sur chacun des mélanges, puis sur une procédure d'appariement des pics présents dans les différents mélanges. La microscopie de force atomique est une technologie récente permettant de mesurer des forces d'interaction entre nano-objets. L'analyse de courbes de forces repose sur des modèles paramétriques par morceaux. Nous proposons un algorithme permettant de détecter les régions d'intérêt (les morceaux) où chaque modèle s'applique puis d'estimer par moindres carrés les paramètres physiques (élasticité, force d'adhésion, topographie, etc.) dans chaque région. Nous proposons finalement une autre approche qui modélise une courbe de force comme un mélange de signaux sources parcimonieux retardées. La recherche des signaux sources dans une image force-volume s'effectue à partir d'un grand nombre de mélanges car il y autant de mélanges que de pixels dans l'image.
14

Caractérisation des courants de fuite à l'échelle nanométrique dans les couches ultra-minces d'oxydes pour la microélectronique

Hourani, Wael 09 November 2011 (has links) (PDF)
La miniaturisation de la structure de transistor MOS a conduit à l'amincissement de l'oxyde de grille. Ainsi, la dégradation et le claquage sous contrainte électrique est devenu l'un des problèmes de fiabilité les plus importants des couches minces d'oxydes. L'utilisation de techniques de caractérisation permettant de mesurer les courants de fuite avec une résolution spatiale nanométrique a montré que le phénomène de claquage des oxydes est un phénomène très localisé. Le diamètre des "points chauds", des endroits où le courant de fuite est très élevé pour une tension appliquée continue, peut-être de quelques nanomètres uniquement. Ceci illustre pourquoi les méthodes de caractérisation avec une résolution spatiale à l'échelle nanométrique peuvent fournir des informations supplémentaires par rapport à la caractérisation classique macroscopique. Il y a deux instruments, dérivés de la microscopie à force atomique (AFM) qui peuvent être utilisés pour faire ce travail, soit le Tunneling Atomic Force Microscope (TUNA) ou le Conductive Atomic Force Microscope (C-AFM). Le mode TUNA qui est utilisé dans notre travail est capable de mesurer des courants très faibles variant entre 60 fA et 100 pA. Notre travail peut être divisé en deux thèmes principaux: - La caractérisation électrique des couches minces d'oxydes high-k (LaAlO3 et Gd2O3) à l'échelle nanométrique en utilisant le Dimension Veeco 3100 où nous avons montré que la différence de leurs techniques d'élaboration influe largement sur le comportement électrique de ces oxydes. - Les caractérisations électriques et physiques à l'échelle nanométrique des couches minces d'oxydes thermiques SiO2 sous différentes atmosphères, c.à.d. dans l'air et sous vide (≈ 10-6 mbar) en utilisant le microscope Veeco E-Scope. L'influence de l'atmosphère a été bien étudiée, où nous avons montré que les phénomènes de claquage des couches minces d'oxydes peuvent être fortement réduits sous vide surtout en l'absence du ménisque d'eau sur la surface de l'oxyde pendant les expériences. En utilisant les plusieurs modes de l'AFM, il a été démontré que l'existence de bosses anormales (hillocks) sur la surface de l'oxyde après l'application d'une tension électrique est une combinaison de deux phénomènes: la modification morphologique réelle de la surface de l'oxyde et la force électrostatique entre les charges piégées dans le volume de l'oxyde et la pointe de l'AFM. Selon les images du courant obtenues par AFM en mode TUNA, deux phénomènes physiques pour la création de ces hillocks ont été proposés: le premier est l'effet électro-thermique et la seconde est l'oxydation du substrat Si à l'interface Si/oxyde.
15

Etude dynamique et structurale de biomolécules par microscopie à force atomique HS-AFM : application à une petite protéine de choc thermique sHsp

Carriou, David 13 December 2012 (has links) (PDF)
La microscopie à force atomique (AFM) permet de visualiser la topographie d'échantillons organiqueset inorganiques à l'échelle atomique. Les innovations les plus récentes offrent désormais la possibilitéd'accéder aux propriétés nano-mécaniques des échantillons (élasticité, adhésion...). Son panel defonctionnalités permet de pallier aux besoins des nanotechnologies, tant dans les domaines de laphysique, de la chimie que de la biologie.Cependant, les besoins nécessaires à la compréhension des processus biologiques imposent aumicroscope à force atomique des vitesses d'acquisitions rapides, inférieures à la seconde par image. Leséquipements classiques n'offrent pas cette possibilité. C'est pour s'affranchir de ce verrou technologique,pour l'étude dynamique, qu'un prototype de microscope à force atomique à haute-vitesse a étédéveloppé (HS-AFM) en partenariat avec l'équipe du Professeur T. Ando à l'Université de Kanazawa(Japon). Il permet d'atteindre des vitesses de balayage identiques aux vitesses vidéos : 25-50 images/s, enmilieu liquide. Le dispositif est en perpétuelle amélioration : nouvelle boucle d'asservissement, domainesde balayage augmentés. La haute résolution est, quant à elle, assurée par des leviers miniaturisés munisde sur-pointes en carbone. Parallèlement à l'innovation du microscope en lui-même, des modulescomplémentaires ont été développés : module pousse seringue et module chauffant.Le potentiel de ce prototype, développé dans le cadre d'un programme ANR PNANO 2008 HSnanobio-Imaging, a été montré via l'étude d'une petite protéine de choc thermique : la protéine sHspLo18. Cette protéine, issue de la bactérie lactique Oenococcus oeni, offrait la possibilité d'étudier deschangements de degrés d'oligomérisation en fonction du pH, ainsi que le rôle chaperon et lipochaperonen cas de stress environnemental d'autres complexes biologiques. L'utilisation des techniques demicroscopie couplée à des études biochimiques sur ce modèle protéique a permis d'appréhender l'effetdes surfaces sur l'adsorption et la dynamique des complexes biologiques. L'interaction protéine - surfacea pu être approchée et s'avère utile au développement des capteurs à protéines
16

Applications and development of acoustic and microwave atomic force microscopy for high resolution tomography analysis / Applications et développement des microscopies à force atomique acoustique et micro-onde pour l'analyse tomographique haute résolution

Vitry, Pauline 10 June 2016 (has links)
La microscopie à force atomique (AFM) est un outil de caractérisation d’échantillons tant organiques qu’inorganiques d’intérêt en physique, en biologie et en métallurgie. Le champ d’investigation de la microscopie AFM reste néanmoins restreint à l’étude des propriétés surfaciques des échantillons et la caractérisation sub-surfacique à l’échelle nanométrique n’est pas envisageable au-delà de la nano-indentation. Lors de ce travail, nous nous sommes intéressés à deux techniques de sonde locale complémentaires pour l’investigation volumique haute résolution.La première technique proposée est la microscopie de champ proche ultrasonore (MS-AFM), mise en place et exploitée en collaboration avec Dr. L. Tétard de l’Université Centrale de Floride. Cette technique fournie des informations localisées en profondeur en utilisant des ondes acoustiques dans la gamme de fréquences du MHz. Une étude complète de l’influence des paramètres de fréquences a été réalisée sur des échantillons de calibration et a permis de valider un modèle d’interprétation numérique. Cette technique ultrasonore, non invasive, a été appliquée à la caractérisation de vésicules lipidiques au sein de bactéries lors d’une collaboration avec les Pr. A. Dazzi et M.-J. Virolle, de l’Université Paris Sud Orsay. Un couplage a été réalisé avec la microscopie AFM infra-rouge (AFM-IR). Cette étude a démontré le potentiel d’investigation et d’analyse volumique et chimique d’échantillons biologiques.La seconde technique étudiée est la microscopie micro-onde (SMM), développée en collaboration avec la société Keysight. Cette technique, tout comme la microscopie acoustique, est non invasive et conduit à une caractérisation physico-chimique basée sur l’interaction de micro-ondes (0.2-16 GHz) avec la matière. Dans le cas de métaux, un lien entre la fréquence et la profondeur d’investigation a été mis en évidence. Cette technique a été appliquée à l’étude de la diffusion d’élément chimique léger au sein de métaux et à la mesure des propriétés mécaniques des matériaux. L’ensemble de ces résultats ouvre un nouveau champ d’investigation de la tomographie 3D dans l’analyse volumique à l’échelle nanométrique que ce soit dans le domaine de la biologie ou de la métallurgie. / The atomic force microscope (AFM) is a powerful tool for the characterization of organic and inorganic materials of interest in physics, biology and metallurgy. However, conventional scanning probe microscopy techniques are limited to the probing surface properties, while the subsurface analysis remains difficult beyond nanoindentation methods. Thus, the present thesis is focused on two novel complementary scanning probe techniques for high-resolution volumetric investigation that were develop to tackle this persisting challenge in nanometrology. The first technique considered, called Mode Synthesizing Atomic Force Microscopy (MSAFM), has been exploited in collaboration with Dr. Laurene Tetard of University of Central Florida to explore the volume of materials with high spatial resolution by means of mechanical actuation of the tip and the sample with acoustic waves of frequencies in the MHz range. A comprehensive study of the impact of the frequency parameters on the performance of subsurface imaging has been conducted through the use of calibrated samples and led to the validation of a numerical model for quantitative interpretation. Furthermore, this non-invasive technique has been utilized to locate lipid vesicles inside bacteria (in collaboration with Pr. A. Dazzi and M.-J. Virolle of Université Paris Sud, Orsay). Furthermore, we have combined this ultrasonic approach with infra-red microscopy, to add chemical speciation aimed at identifying the subsurface features, which represents a great advance for volume and chemical characterization of biological samples. The second technique considered is the Scanning Microwave Microscopy, which was developed in collaboration with Keysight society. Similar to acoustic-based microscopy, this non-invasive technique provided physical and chemical characterizations based on the interaction of micro-waves radiations with the matter (with frequency ranging from 0.2 and 16 GHz). Particularly, for metallic samples we performed volumetric characterization based on the skin effect of the materials. On the other hand, we have used this technique to analyze the diffusion of light chemical elements in metals and measured the effect of changes in mechanical properties of materials on their conductivity.Overall, these results constitute a new line of research involving non-destructive subsurface high resolution analysis by means of the AFM of great potential for several fields of research.
17

Étude de l’influence de la dissolution sous contrainte sur les propriétés mécaniques des solides : fluage du plâtre / Study of the influence of pressure solution on the mechanical properties of solids : plaster creep

Pachon-Rodriguez, Edgar-Alejandro 14 December 2011 (has links)
L’importante augmentation de fluage des plaques de plâtre en milieu humide est un vieux problème dans l’industrie du bâtiment, dont l’origine n’est pas encore établie. Afin d’en comprendre le mécanisme une étude à trois échelles (macro : réponse mécanique, micro : cinétique de dissolution et nano : observation atomique) a été réalisée. Une corrélation forte existe entre le fluage du plâtre en immersion et la cinétique de dissolution du gypse. La concordance de cette corrélation avec une loi de déformation par dissolution sous contrainte, très utilisés en géologie, permet de proposer la dissolution sous contrainte comme un des mécanismes responsables du fluage du plâtre en immersion. L’évolution de la topographie de la surface du cristal de gypse immergé dans une solution aqueuse de gypse est observée par microscopie à force atomique (AFM). La cinétique de migration des marches atomiques est très dépendante de la sous-saturation de la solution, de la force d’appui de la pointe de l’AFM ainsi que des additifs utilisés. L’étude de l’influence de la force d’appui sur les vitesses des marches met en évidence la présence de deux mécanismes complètement différents. A fortes forces (> 15 nN) on observe un mécanisme d’usure de la surface, tandis qu’à faibles forces (< 10 nN) le mécanisme observé semble être la dissolution sous contrainte. L’évolution des vitesses des marches atomiques avec la force appliquée par la pointe est concordante avec une loi connue de dissolution sous contrainte. / The huge enhancement of the creep of plasterboard by humid environments is an old problem in the building industry, but its origin remains unknown. To understand this mechanism a three scales study (macro : mechanical behavior, micro : dissolution kinetics, nano : atomic observation) has been done. There is a strong correlation between wet plaster creep and gypsum dissolution kinetics. The concordance between this correlation and the law of deformation by pressure solution, well-known in geology, permits to propose pressure solution as one of the mechanisms responsible of wet plaster creep. The topological evolution of the cleaved surface of a gypsum single crystal during its dissolution in a flowing under-saturated aqueous solution has been observed with an atomic force microscope. The kinetics of step migration strongly depends on the saturation state of the solution, the force applied by the tip on the surface, as well as the used additives. The study of the influence of the force applied by the tip on the step velocity evidence two different dissolution enhancement regimes. At high forces (> 15 nN) a corrosive wear behavior is observed, while at low forces (< 10 nN) pressure solution is the observed mechanism. The step velocity evolution with the force obeys the known kinetic law of pressure solution.
18

Etude dynamique et structurale de biomolécules par microscopie à force atomique HS-AFM : application à une petite protéine de choc thermique sHsp / Dynamic and structural study of biomolecules by atomic force microscopy HS-AFM : application to a small heat shock protein sHsp

Carriou, David 13 December 2012 (has links)
La microscopie à force atomique (AFM) permet de visualiser la topographie d’échantillons organiqueset inorganiques à l’échelle atomique. Les innovations les plus récentes offrent désormais la possibilitéd’accéder aux propriétés nano-mécaniques des échantillons (élasticité, adhésion…). Son panel defonctionnalités permet de pallier aux besoins des nanotechnologies, tant dans les domaines de laphysique, de la chimie que de la biologie.Cependant, les besoins nécessaires à la compréhension des processus biologiques imposent aumicroscope à force atomique des vitesses d’acquisitions rapides, inférieures à la seconde par image. Leséquipements classiques n’offrent pas cette possibilité. C’est pour s’affranchir de ce verrou technologique,pour l’étude dynamique, qu’un prototype de microscope à force atomique à haute-vitesse a étédéveloppé (HS-AFM) en partenariat avec l’équipe du Professeur T. Ando à l’Université de Kanazawa(Japon). Il permet d’atteindre des vitesses de balayage identiques aux vitesses vidéos : 25-50 images/s, enmilieu liquide. Le dispositif est en perpétuelle amélioration : nouvelle boucle d’asservissement, domainesde balayage augmentés. La haute résolution est, quant à elle, assurée par des leviers miniaturisés munisde sur-pointes en carbone. Parallèlement à l’innovation du microscope en lui-même, des modulescomplémentaires ont été développés : module pousse seringue et module chauffant.Le potentiel de ce prototype, développé dans le cadre d’un programme ANR PNANO 2008 HSnanobio-Imaging, a été montré via l’étude d’une petite protéine de choc thermique : la protéine sHspLo18. Cette protéine, issue de la bactérie lactique Oenococcus oeni, offrait la possibilité d’étudier deschangements de degrés d’oligomérisation en fonction du pH, ainsi que le rôle chaperon et lipochaperonen cas de stress environnemental d’autres complexes biologiques. L’utilisation des techniques demicroscopie couplée à des études biochimiques sur ce modèle protéique a permis d’appréhender l’effetdes surfaces sur l’adsorption et la dynamique des complexes biologiques. L’interaction protéine – surfacea pu être approchée et s’avère utile au développement des capteurs à protéines / The atomic force microscopy (AFM) gives access to the topography of organic and inorganic samplesat the atomic scale. The latest innovations offer the possiblity to understand the sample nano-mechanicalproperties (elasticity, adhesion...). Its feature set allows overcoming the demands of nanotechnology,both in the fields of physics, chemistry and biology.However, understanding biological processes require faster acquisitions for the atomic forcemicroscopy, less than a second per frame. As conventional equipment does not offer the possibility toovercome the constraint of time for dynamical studies, a prototype of high-speed atomic forcemicroscope (HS-AFM) was developed in partnership with Professor T. Ando group of Kanazawa University(Japan). It can reach scanning video speed: 25-50 frames/s in a liquid medium. The device is beingconstantly improved: new feedback control, larger scanning sizes. The resolution is provided byminiaturized cantilevers with carbon EBD-tips. In parallel to innovative modules on the microscope, addonshave been developed: syringe pump and heating modules.The potential of the prototype, developed within the framework of the program ANR PNANO 2008HS-nanobio-Imaging, has been shown through the study of a small heat shock protein: the protein sHspLo18. This protein, from the lactic acid bacterium Oenococcus oeni, offered the possibility of a variouschanges of oligomerization degrees according to the pH, and also the chaperone and lipochaperon activityof protein under the influence of an environmental stress. The use of these techniques of microscopiescoupled with biochemical studies on this proteic model allowed to dread the effect of surfaces on theadsorption and the dynamics of biological complexes. The interaction protein – surface coulb be toapprehend and proves to be useful for the development of protein sensors developed in the laboratory
19

Propriétés structurales, électroniques et ferroélectriques de systèmes Ln₂Ti₂O₇ (Ln=lanthanides) et d'hétérostructures SrTiO₃ / BiFeO₃ / Structural, electronic and ferroelectric properties of Ln₂Ti₂O₇ oxydes (Ln = lanthanide) and SrTiO₃ / BiFeO₃heterostructures

Bruyer, Emilie 21 November 2012 (has links)
Ce manuscrit est consacré à l’analyse théorique et expérimentale d’oxydes Ln2Ti2O7 (Ln = La, Nd, Sm, Gd) et BiFeO3.Les propriétés physiques de La2Ti2O7 et Nd2Ti2O7 ont été investiguées au moyen de calculs ab initio, confirmant ainsi leur ferroélectricité. D’autres oxydes de la famille Ln2Ti2O7, Sm2Ti2O7 et Gd2Ti2O7, ont ensuite été étudiés selon les mêmes méthodes théoriques. Nos calculs ont révélé une meilleure amplitude de polarisation pour ces composés par rapport au La2Ti2O7 et au Nd2Ti2O7. La deuxième partie de ce travail est consacrée aux propriétés structurales, électroniques et ferroélectriques du BiFeO3. L’évolution de ses propriétés lorsqu’il est soumis à une contrainte épitaxiale ont été investiguées au moyen de calculs ab-initio et de mesures en microscopie à champ proche réalisées sur des couches minces déposées sur un substrat de SrTiO3(001). Nos résultats mettent en évidence une modification de la structure interne du matériau sous effet de contrainte, qui se traduit par une réorientation progressive de la polarisation spontanée suivant la direction [001]. Notre étude s’est ensuite tournée vers l’élaboration et l’analyse des propriétés structurales et ferroélectriques de superréseaux (SrTiO3)n(BiFeO3)m. Nos calculs ont mis en évidence que la contrainte épitaxiale imposée au superréseau offrait un contrôle accru des propriétés du BiFeO3 par rapport à son comportement lorsqu’il est déposé seul en couches minces. Les analyses en microscopie à champ proche ont montré une réduction de la tension coercitive de tels films par rapport à celle mesurée sur des bicouches SrTiO3/BiFeO3 ou sur une couche mince de BiFeO3. / In this work, first-principles calculations and experimental measurements have been done in order to investiguate the structural, electroniq and ferroelectric properties of Ln2Ti2O7 (Ln = La, Nd, Sm, Gd) and BiFeO3 oxydes. Calculations on La2Ti2O7 and Nd2Ti2O7 confirmed their ferroelectricity. Other oxydes belonging to the Ln2Ti2O7 family have also been investigated. The results showed an enhancement of the spontaneous polarization within these compounds compared to that of La2Ti2O7 and Nd2Ti2O7. The second part of this work is related to the structural and ferroelectric properties of bismuth ferrite BiFeO3. The evolution of its properties when undergoing an epitaxial strain have been investigated by ab initio calculations and piezoresponse force microscopy measurements on thin films deposited on a (001)-SrTiO3 substrate. Our results showed a modification of the inner structure of BiFeO3 under stain, leading to a continuous reorientation of the spontaneous polarization vector towards [001]. The third part of our study consists in the computational design and synthesis of (SrTiO3)n(BiFeO3)m superlattices. Our calculations showed that epitaxial strain imposed to the superlattice brings a further control of physical properties of BiFeO3 as compared with its behaviour when deposited alone in a thin film. PFM analysis showed a decrease of the coercive field for STO/LNO/(STO)n(BFO)m superlattices as compared with those measured on STO/BFO bi-layers and on BiFeO3 thin films.
20

Système de contrôle pour microscope à force atomique basé sur une boucle à verrouillage de phase entièrement numérique

Bouloc, Jeremy 29 May 2012 (has links)
Un microscope à force atomique (AFM) est utilisé pour caractériser des matériaux isolant ou semi-conducteur avec une résolution pouvant atteindre l'échelle atomique. Ce microscope est constitué d'un capteur de force couplé à une électronique de contrôle pour pouvoir correctement caractériser ces matériaux. Parmi les différents modes (statique et dynamique), nous nous focalisons essentiellement sur le mode dynamique et plus particulièrement sur le fonctionnement sans contact à modulation de fréquence (FM-AFM). Dans ce mode, le capteur de force est maintenu comme un oscillateur harmonique par le système d'asservissement. Le projet ANR Pnano2008 intitulé : ”Cantilevers en carbure de silicium à piézorésistivité métallique pour AFM dynamique à très haute fréquence" a pour objectif d'augmenter significativement les performances d'un FM-AFM en développant un nouveau capteur de force très haute fréquence. Le but est d'augmenter la sensibilité du capteur et de diminuer le temps nécessaire à l'obtention d'une image de la surface du matériau. Le système de contrôle associé doit être capable de détecter des variations de fréquence de 100mHz pour une fréquence de résonance de 50MHz. Etant donné que les systèmes présents dans l'état de l'art ne permettent pas d'atteindre ces performances, l'objectif de cette thèse fut de développer un nouveau système de contrôle. Celui-ci est entièrement numérique et il est implémenté sur une carte de prototypage basée sur un FPGA. Dans ce mémoire, nous présentons le fonctionnement global du système ainsi que ses caractéristiques principales. Elles portent sur la détection de l'écart de fréquence de résonance du capteur de force. / An atomic force microscope (AFM) is used to characterize insulating materials or semiconductors with a resolution up to the atomic length scale. The microscope includes a force sensor linked to a control electronic in order to properly characterize these materials. Among the various modes (static and dynamic), we focus mainly on the dynamic mode and especially on the frequency modulation mode (FM-AFM). In this mode, the force sensor is maintained as a harmonic oscillator by the servo system. The research project ANR Pnano2008 entitled: "metal piezoresistivity silicon carbide cantilever for very high frequency dynamic AFM" aims to significantly increase the performance of a FM-AFM by developing new very high frequency force sensors. The goal is to increase the sensitivity of the sensor and to decrease the time necessary to obtain topography images of the material. The control system of this new sensor must be able to detect frequency variations as small as 100mHz for cantilevers with resonance frequencies up to 50MHz. Since the state-of-the-art systems doe not present these performances, the objective of this thesis was to develop a new control system. It is fully digital and it is implemented on a FPGA based prototyping board. In this report, we present the system overall functioning and its main features which are related to the cantilever resonant frequency detection. This detection is managed by a phase locked loop (PLL) which is the key element of the system.

Page generated in 0.0472 seconds