Nanoparticles for Targeted Drug Delivery

Chow, Gan-Moog 01 1900 (has links)
Nanoparticles were synthesized and modified for target drug delivery. The research involved the aqueous synthesis of near infrared (NIR) sensitive Au-Au<sub>2</sub>S nanoparticles. An anti-cancer drug (<i>cis-platin</i>) was subsequently adsorbed onto the Au-Au<sub>2</sub>S nanoparticle surface via the 11-mercaptoundecanoic acid layers. The results showed that the degree of adsorption of cis-platin onto Au-Au<sub>2</sub>S nanoparticles was controlled by the pH value of solution, and the rate of drug release was sensitive to NIR irradiation. The results of the synthesis, drug-release properties and nanoparticle-cell interactions will be discussed. / Singapore-MIT Alliance (SMA)
412

Minimally invasive assessment of lymphatic pumping pressure using near infrared imaging

Akin, Ryan E. 14 January 2013 (has links)
Although the major functions of the lymphatic system are fairly well defined, its vasculature has yet to be well characterized in comparison to its blood vasculature counterpart. Recent advances in optical imaging techniques have allowed for more detailed and quantitative evaluations of lymph flow dynamics and mechanism. A rat tail is often used for investigations of lymph flow because of the simple geometry, superficial nature, and disease progression models of its collecting lymphatic vessels. In this study, a pressure cuff system was fabricated and coupled with an existing functional near infrared (NIR) imaging system to measure the overall pumping pressure of the lymphatic vessels of a rat tail. In addition to adapting the system for use on rodents, previous systems used for measuring lymphatic pumping pressure in humans were improved upon in several ways. The system defined here utilizes closed-loop feedback control of pressure application at smaller, more precise intervals. Using this device, a significant difference in lymphatic vessel pumping pressure was detected between a control case and a treatment case in which a vasoactive substance with a nitric oxide donor (GTNO ointment) was applied to the tail. Although it is known that nitric oxide plays a crucial physiologic role in propagation of flow through lymphatic vessels, this study has quantified its significant pharmacological reduction of pumping pressure for the first time.
413

Synthesis and Energetics of Gold Nanoclusters Tailored by Interfacial Bonding Structure

Zhenghua, Tang 07 August 2012 (has links)
In addition to the well known quantum confinement effects resulted from size and shape, interfacial bond structure is another factor, affecting the properties of the nanomaterial that is rarely studied. Inspired by the “Au-S-Au” staple motif discovered from the crystal structure of monothiol protected Au102 nanocluster (Science, 2007, 318, 430), dithiol molecules (e. g. 1, 2-dithiol, 1, 4-dithiol, etc.) with molecular structural constraint have been employed to create dithiolate protected clusters or mixed monothiolate and dithiolate protected clusters. The structure and properties of the Au clusters are expected to change due to two effects: The entropy gain of dithiol over monothiol protection and the constraint to the formation of the thiol bridging motif. DMPS (1, 2-dithiol molecule) stabilized clusters with characteristic absorption bands have been obtained, and characterized by multiple techniques. Monolayer reaction on gold core surface between the monothiol tiopronin and dithiol DMPS has been performed, and the mechanism has been probed. Mixed phenylethanethiolate and durene-dithiolate (1, 4-dithiol molecule) protected Au130 clusters with rich electrochemical features have been created, and the optical and electrochemical energetics have been successfully correlated based on core and core-ligand energy states. Furthermore, the impact of 1, 4-dithiolate-Au bonding on the near infrared luminescence has been studied.
414

Thoracic Aortic Surgery : Epidemiology, Outcomes, and Prevention of Cerebral Complications

Olsson, Christian January 2006 (has links)
The mortality of thoracic aortic diseases (mainly aneurysms and dissections) is high, even with surgical treatment. Epidemiology and long-term outcomes are incompletely investigated. Stroke is a major complication contributing to mortality, morbidity, and possibly to reduced quality of life. Study I Increasing incidence of thoracic aortic diseases 1987 – 2002 was demonstrated (n=14229). Annual number of operations increased eight-fold. Overall long-time survival was 92%, 77%, and 57% at 1, 5, and 10 years. Risk of operative and long-term mortality was reduced across time. Study II 2634 patients operated on the proximal thoracic aorta (Swedish Heart Surgery register) were examined. Aortic valve replacement, coronary revascularization, emergency operation, and age were independently associated with surgical death. Long-term mortality was similar for aneurysms and dissections. Operative mortality was reduced (13.7% vs 7.2%) for aneurysms but remained unchanged (22.3% vs 22.4%) for dissections across time. Study III 65 patients underwent selective antegrade cerebral perfusion (SACP) uni- or bilaterally. Stroke was significantly more common after unilateral SACP (29% vs 8%, p=0.045), confirmed by propensity score-matched analysis. Subclavian artery cannulation with Seldinger-technique entailed vascular complication in one case (1.5%). Study IV Near-infrared spectroscopy (NIRS) was used to monitor cerebral tissue saturation (rSO2) during SACP in 46 patients. Lower rSO2 were encountered (1) in patients suffering a stroke (2) with unilateral SACP, and (3) in the affected hemisphere of stroke victims. A decrease of rSO2 by 14 – 21% from baseline increased the risk of stroke significantly. Study V Quality of life (QoL) in 76 survivors of thoracic aortic surgery was examined with the SF-36 health questionnaire. Except for pain, QoL was reduced in all dimensions. QoL was not affected by acuity of operation. Tendencies of lower QoL after descending aortic operations, after major complications, and with persistent dysfunction were non-significant.
415

The mutagenesis of Sorghum bicolour (L.) Moench towards improved nutrition and agronomic performance.

January 2009 (has links)
In the breeding of grain sorghum (Sorghum bicolour L. Moench) towards improved nutrition and agronomic performance, new methodologies are required to increase genetic diversity and lower the inputs required to track and screen breeding populations. Near-infrared calibration models were developed by partial least squares (PLS) and test-set validation on 364 sorghum samples to predict crude protein and moisture content on whole-grain and milled flour samples. Models using milled flour spectra were more accurately predictive than those from whole grain spectra for all constituents (eg. Protein: R2 = 0.986 on flour vs R2 = 0.962 on whole grain). Discriminant calibrations were established to classify grain colour using partial least squares discriminant analysis (PLS-DA) based upon CIE L*a*b* reference values and visual ranking. Preliminary calibrations were developed for quantities of 18 amino acids, fat and apparent metabolisable energy (AME) on 40 samples using cross-validation, highlighting potential for reliable calibration for these parameters in sorghum. An investigation into the potential of 12C6+ heavy-ion beam mutagenesis of sorghum seed was undertaken by treatment at RIKEN Accelerator Research Facility (Saitama, Japan) and subsequent breeding at Ukulinga research farm and analysis at the Department of Plant Pathology, University of KwaZulu-Natal, Pietermaritzburg, South Africa. Dosage rates of 75, 100 and 150 Gy were compared in seven sorghum varieties to establish optimal dose treatments as determined by germination and survival rates, visible morphological changes and field data over two seasons of field trials. Crude protein variation within the M2 generation was analysed to compare dose rate effects. The need for higher dose rates was indicated by few quantified differences between treatments and control although good correlations between protein deviation and treatment dose rate were elucidated. Differences in varietal response suggest a need to optimize dose rate for specific varieties in future endeavours. In addition, all mutagenized populations were screened for crude protein content using near-infrared spectroscopy (NIRS). Significant differences in protein levels and standard deviations were observed between treated self-pollinated M2 generations and untreated control populations. Individual plants displaying significantly different protein levels were isolated. / Thesis (M.Sc.)-University of KwaZulu-Natal, Pietermaritzburg, 2009.
416

Reactive Hyperemia as endothelial function determinant using plethysmography methods

Olamaei, Nina 01 1900 (has links)
L’atteinte de la fonction endothéliale représente une phase précoce de l’athérosclérose, un stade où les patients sont généralement asymptomatiques. Il existe donc un intérêt certain à détecter la dysfonction endothéliale. Nous avons développé une technique de mesure des variations de flot artériel au niveau des membres supérieurs, basée sur la spectroscopie proche infrarouge (NIRS). Cette approche permettrait d’étudier le niveau d’atteinte vasculaire et probablement de quantifier le degré de dysfonction endothéliale périphérique lors d’une hyperémie réactive. L'expérience a été exécutée sur deux cohortes de 13 et de 15 patients et a été comparée à la pléthysmographie par jauge de contrainte (SGP) qui est considérée comme une méthode de référence. Par la suite, nous avons caractérisé la réponse endothéliale par modélisation de la courbe hyperémique du flot artériel. Des études préliminaires avaient démontré que la réponse hyperémique adoptait majoritairement une forme bi-modale. Nous avons tenté de séparer les composantes endothéliales-dépendantes et endothéliales-indépendantes de l’hyperémie. La quantification des deux composantes de la réaction hyperémique permet de calculer un indice de la ‘santé’ du système endothélial local. Cet indice est nommé le ηfactor. Les résultats montrent une forte corrélation des mesures de flots entre la technique développée et la méthode de référence (r=0.91). Nous avons conclu que NIRS est une approche précise pour la mesure non-invasive du flot artériel. Nous avons obtenu une bonne répétabilité (ICC = 0.9313) pour le ηfactor indiquant sa robustesse. Cependant des études supplémentaires sont nécessaires pour valider la valeur de diagnostic du facteur défini. Mots clés: hyperémie réactive, réponse myogénique, oxyde nitrique, athérosclérose, spectroscopie proche infrarouge / Atherosclerotic diseases are mainly caused by coronary and peripheral blood vessel disorders. Endothelial dysfunction represents an early phase in these diseases, when patients are generally asymptomatic. We developed a technique, based on near infrared spectroscopy (NIRS), for measurement of arterial blood flow variations in limbs during reactive hyperemia. The technique allows the study of the level of vascular impairment and probably quantifying the level of endothelial dysfunction at peripheral arteries. The experiment was performed on two cohorts of 13 and 15 patients and was compared to strain gauge plethysmography (SGP) which is considered as gold standard. Afterward, we characterized endothelial reaction during reactive hyperemia through blood flow variations by modeling the hyperemic curve. Preliminary studies have shown that the hyperemic response generally adopts a bimodal form. The first peak was attributed to myogenic reaction that is endothelial independent and the second one to local endothelial cells reaction. The quantification of the two hyperemic response components makes it possible to calculate an index of ‘health’ for local endothelial cells, named ηfactor. The results showed a strong correlation (r = 0.91) of blood flow measurements between the developed method and the gold standard. We concluded that NIRS is a precise technique for non-invasive measurement of blood flow. Moreover, we found a high repeatability (ICC = 0.9313) of the ηfactor in repeated measurements indicating its robustness. Nonetheless, more studies are required to validate the diagnosis value of the defined factor. Key words: reactive hyperemia, myogenic response, endothelial dependent vasodilatation, nitric oxide, atherosclerosis, near infrared spectroscopy (NIRS)
417

Influence du vieillissement sur la réorganisation cérébrale dans la compréhension du discours : apport de l’imagerie optique

Demers, Catrine 08 1900 (has links)
Au cours du vieillissement, des modifications dans la compréhension du discours ont été rapportées, attribuées en partie aux changements cognitifs encourus lors du vieillissement. Néanmoins, diverses études suggèrent une réorganisation cérébrale lors du vieillissement. Cette étude a pour but d'évaluer l'influence de l'âge lors d'une tâche de compréhension du discours à l'aide de l'imagerie optique. Comme première hypothèse, il est attendu que les participants jeunes auront plus de bonnes réponses au niveau des micropropositions et des macropropositions et des performances équivalentes au niveau du modèle de situation. La deuxième hypothèse est que les réseaux neuronaux utilisés lors de la compréhension du discours subiront une réorganisation cérébrale lors du vieillissement. Trente-deux participants ont pris part à cette étude : 16 jeunes adultes et 16 adultes âgés. Alors que les participants étaient sous enregistrement en imagerie optique au niveau du cortex préfrontal (CPF), ils ont lu des courtes histoires chacune suivie d’une phrase et devaient décider si elle était en accord ou non avec la précédente histoire. Les résultats ne montrent aucune différence entre les groupes au niveau de l’exactitude des réponses, contrairement à la littérature. Le CPF a été davantage activé par les adultes âgés comparativement aux jeunes adultes témoignant d’une réorganisation cérébrale. / During aging, changes in discourse comprehension have been reported, attributed in part by cognitive changes that occur during aging. Moreover, various studies suggest a cerebral reorganization with aging. This study aims to evaluate the influence of aging on cerebral reorganization during discourse comprehension using near infrared spectroscopy (NIRS). The first hypothesis is that younger adults will have better accuracy on micropropositions and macropropositions, but will have equivalent performance for the situation model. The second hypothesis is that the neural networks used for discourse comprehension will be reorganized during aging. Thirty-two participants took part in this study: 16 young adults and 16 older adults. While undergoing NIRS recording on the prefrontal cortex (PFC), the participants read short stories each followed by a sentence deciding if it was in agreement or not with the previous story. Results didn’t show any differences for accuracy between the group, in opposition with the literature. The PFC was more activated by the older adults compared to the younger adults showing a cerebral reorganization.
418

Apports de l’imagerie optique à l’étude de l’impact du niveau de scolarité sur la contribution des lobes frontaux à la production de mots

Maheux, Manon 08 1900 (has links)
Le vieillissement normal est associé à une réorganisation cérébrale qui peut être influencée par plusieurs facteurs. Des théories comme la réserve cognitive de Stern (2002) tentent d’expliquer les effets de ces différents facteurs. Certains, le niveau de scolarité par exemple, sont encore mal connus. Pourtant, le niveau de scolarité est connu pour avoir un impact sur les performances cognitives tout au long de la vie. Le but de ce mémoire est d’étudier les effets du niveau de scolarité sur l’oxygénation cérébrale de personnes âgées en santé lors d’une tâche d’évocation lexicale orthographique et sémantique. Chaque tâche est divisée selon un critère « plus productive » et « moins productive ». Les âgés faiblement scolarisés produisent moins de mots que les âgés fortement scolarisés. De plus, la différence de mots produits entre le critère plus productif et moins productif est plus grande pour la tâche sémantique que pour la tâche orthographique. Du point de vue hémodynamique, les deux groupes ont des activations semblables, contredisant le phénomène HAROLD. De plus, les participants peu scolarisés tendent à activer de façon plus importante l’hémisphère gauche, peu importe la tâche ou la condition. Par contre, les activations varient selon la tâche et la condition dans le cas du groupe fortement scolarisé. / Normal aging is associated with cerebral reorganisation which can be influenced by many factors. For example, the theory cognitive reserve (Stern, 2002) is trying to explain how those factors can have an impact on the reorganization. However, some factors, such as educational level, are known to have an impact on cognitive performance. The aim of this dissertation is to study the effect of educational level in cerebral oxygenation of healthy older adults during both phonologic and semantic verbal fluency tasks. Each task is divided into two criteria: more productive and less productive. Behavioural data showed that less educated elderly generate fewer words than more educated ones for both tasks. Moreover, the differences between the number of words for the more productive criterion and the less productive one are higher for the semantic than for the phonologic task. NIRS data showed that both groups activated prefrontal cortex, without difference between them. In addition, less educated participants tend to have bigger activations in the left hemisphere regardless of the task and the criterion. On the other hand, higher educated participants’ activations vary according to the task and the criterion unlike the HAROLD model’s predictions.
419

Développement d’un système de spectroscopie infrarouge résolue temporellement pour la quantification des concentrations d’hémoglobine cérébrale

Leclerc, Paul-Olivier 11 1900 (has links)
L’étude du cerveau humain est un domaine en plein essor et les techniques non-invasives de l’étudier sont très prometteuses. Afin de l’étudier de manière non-invasive, notre laboratoire utilise principalement l’imagerie par résonance magnétique fonctionnelle (IRMf) et l’imagerie optique diffuse (IOD) continue pour mesurer et localiser l’activité cérébrale induite par une tâche visuelle, cognitive ou motrice. Le signal de ces deux techniques repose, entre autres, sur les concentrations d’hémoglobine cérébrale à cause du couplage qui existe entre l’activité neuronale et le flux sanguin local dans le cerveau. Pour être en mesure de comparer les deux signaux (et éventuellement calibrer le signal d’IRMf par l’IOD), où chaque signal est relatif à son propre niveau de base physiologique inconnu, une nouvelle technique ayant la capacité de mesurer le niveau de base physiologique est nécessaire. Cette nouvelle technique est l’IOD résolue temporellement qui permet d’estimer les concentrations d’hémoglobine cérébrale. Ce nouveau système permet donc de quantifier le niveau de base physiologique en termes de concentrations d’hémoglobine cérébrale absolue. L’objectif général de ma maîtrise était de développer un tel système afin de l’utiliser dans une large étude portant sur la condition cardiovasculaire, le vieillissement, la neuroimagerie ainsi que les performances cognitives. Il a fallu tout d’abord construire le système, le caractériser puis valider les résultats avant de pouvoir l’utiliser sur les sujets de recherche. La validation s’est premièrement réalisée sur des fantômes homogènes ainsi qu’hétérogènes (deux couches) qui ont été développés. La validation des concentrations d’hémoglobine cérébrale a été réalisée via une tâche cognitive et appuyée par les tests sanguins des sujets de recherche. Finalement, on présente les résultats obtenus dans une large étude employant le système d’IOD résolue temporellement en se concentrant sur les différences reliées au vieillissement. / Our understanding of the functional organization of the human brain has been greatly influenced by the development of new medical imaging techniques. Pr. Hoge’s research has focused on the use of functional magnetic resonance imaging (fMRI) and continuous diffuse optical imaging (DOI) for non-invasive localization and quantification of brain activity associated with behavioral stimuli or tasks (e.g. cognitive, motor or visual). The respective signals of both techniques are based on cerebral haemoglobin concentrations because of the coupling that exists between neuronal activity and cerebral blood flow. Relating BOLD fMRI signals with those acquired using DOI has been complicated by the fact that fMRI yields fractional change values, while the majority of DOI methods have provided absolute changes from an unknown baseline. To address this, we adopted a newer technique known as time-resolved DOI, which allows absolute quantification of cerebral haemoglobin concentrations. Time-resolved DOI thus has the capacity to quantify the subject’s resting hemoglobin concentrations in absolute micromolar units. The main objective of my masters’ project was to implement and optimize a time-resolved DOI system for use in a large study exploring the links between cardiovascular fitness, aging, neuroimaging markers, and cognitive performance. In this thesis we describe the fabrication of the system, followed by its characterisation and validation using solid optical phantoms (homogeneous and heterogeneous) developed for this purpose. Haemoglobin concentrations obtained non-invasively with the system are validated against blood draws, while the sensitivity to variations in concentration are assessed during a cognitive task. Finally, we present the results of a large study in which the time-resolved DOI system was used to characterize age-related vascular changes in the brain.
420

Entwicklung eines breitbandigen Cavity-Ring-Down-Spektrometers unter Verwendung nahinfraroter, inkohärenter Strahlung / Development of a broadband cavity ring-down spectrometer using incoherent near-infrared radiation

Salffner, Katharina January 2013 (has links)
In der vorliegenden Arbeit werden verschiedene Spektrometer für die Analyse von Gasen bzw. Gasgemischen vorgestellt und deren Design, Aufbau, Charakterisierung und Optimierung beschrieben. Das Resultat der Optimierung und Weiterentwicklungen ist ein spektral breitbandiges Cavity-Ring-Down-Spektrometer (CRD-Spektrometer). Ausgangspunkt der hier vorgestellten Arbeit ist ein Spektrometer auf Basis klassischer Absorptionsspektroskopie in einer Multireflexionszelle. Für dieses Spektrometer wurde als Strahlquelle ein Superkontinuumlaser verwendet. Der Vorteil dieses Spektrometers liegt in seiner Kompaktheit. Mit diesem Spektrometer wurden Absorptionsspektren von mehreren Reingasen und einem Gasgemisch über einen Wellenlängenbereich von 1500 nm – 1700 nm aufgenommen. Der qualitative Vergleich mit zu erwartenden Spektren, welche auf der HITRAN-Datenbank basieren, zeigte eine gute Übereinstimmung. Die quantitative Interpretierbarkeit der Daten war jedoch stark eingeschränkt aufgrund des hohen zufälligen und systematischen Fehlers der Messungen. Als Konsequenz aus der als nicht zufriedenstellend bewerteten quantitativen Interpretierbarkeit der Daten wurde eine alternative Messmethode gesucht, welche eine höhere Sensitivität und Genauigkeit ermöglicht. Die Wahl fiel auf die Cavity-Ring-Down-Spektroskopie, eine resonatorgestützte Variante der Absorptionsspektroskopie. Wesentliche Vorteile dieser Technik sind a) die Unabhängigkeit von Leistungsschwankungen der Strahlquelle, b) ein effektiver Absorptionsweg von bis zu mehreren Kilometern, welcher sich unmittelbar auf die Sensitivität der Messungen auswirkt, c) die Ermittlung absoluter Absorberkonzentrationen, ohne die Notwendigkeit einer Kalibrierung oder den Vergleich mit einer Referenzzelle und d) die Vernachlässigbarkeit von Absorptionen außerhalb des Resonators. Als notwendiger Zwischenschritt auf dem Weg zu einem breitbandigen CRD-Spektrometer wurde zunächst ein monochromatisches CRD-Spektrometer designt, aufgebaut und charakterisiert. Für die effektive Einkopplung von Strahlungsenergie in einen Resonator ist die Anpassung der Strahlparameter an die Mode des Resonators notwendig. Voraussetzung dieser Anpassung ist die Kenntnis der Strahlparameter, welche experimentell ermittelt wurden. Im Laufe des Aufbaus des Spektrometers ergab sich, dass trotz der Modenanpassung die Einkopplung der Strahlungsenergie in den Resonator gestört wurde. Daraufhin wurden systematisch mögliche Ursachen dieser Störung untersucht und das Spektrometer optimiert. Mit diesem optimierten Spektrometer wurden Spektren gemessen, welche sowohl qualitativ als auch quantitativ gut mit den zu erwartenden Spektren übereinstimmen. Als Nachweisgrenze dieses Spektrometers wurde ein Wert für den Absorptionskoeffizienten alpha von 10^-8 cm-1 bestimmt. Mit dem monochromatischen CRD-Spektrometer war es zudem möglich, isotopenspezifische Messungen durchzuführen. Für das breitbandige Spektrometer wurde als Strahlquelle eine ASE-Diode (amplified spontaneous emission) verwendet. Dabei handelt es sich um eine inkohärente Strahlquelle. Mittels Messungen nach dem Prinzip der Cavity-Enhanced-Absorptionsspektroskopie wurde die generelle Funktionalität des resonatorgestützten Spektrometers überprüft. Anschließend wurden die wellenlängenabhängigen Abklingsignale des leeren und des mit einem CO2-Luft-Gemisch gefüllten Resonators gemessen und ebenfalls mit den zu erwartenden Spektren verglichen. Qualitativ stimmen die experimentellen Spektren gut mit den zu erwartenden Spektren überein. Für die quantitative Interpretation der Daten wurde ein spezieller Algorithmus entwickelt, der die spektrale Auflösung des Systems berücksichtigt. Mit dem vorgestellten Spektrometer ist so die qualitative und quantitative Interpretation der Spektren möglich. Die Nachweisgrenze des breitbandigen Cavity-Ring-Down-Spektrometers wurde zu einem Wert von alpha = 8x10^-7 cm-1 bestimmt. Der systematischen und der zufällige Fehler der Messungen lagen bei Werten von ca. 1%. Bei diesem Spektrometer handelt es sich um einen Prototyp. Mittels Optimierung des Systems lassen sich sowohl der Wert der Nachweisgrenze als auch die Fehler der Messungen verbessern. / This thesis presents the design, set-up, characterisation and optimization of various spectrometers to be used for the analysis of gases and gas mixtures. The result of this optimization and its further development is a spectrally broadband cavity ring-down spectrometer (CRD spectrometer), which uses an incoherent light source that emits in the near-infrared. The starting point of the development was a spectrometer which is based on classic absorption spectroscopy inside a multipass cell. This spectrometer uses a supercontinuum laser as light source. The advantage of this spectrometer is its compactness. With this spectrometer, the spectra of various gases and a gas mixture were detected in the spectral range of 1500 nm to 1700 nm. The experimentally derived spectra are in good qualitative accordance to expected spectra based on the HITRAN database. Nevertheless, the qualitative interpretation of the data reveals significant systematic and random errors. As a consequence, a different spectroscopic approach was chosen. The method of choice was cavity ring-down spectroscopy. The advantages of this technique are a) the independence from power fluctuations of the light source, b) an effective absorption path length of up to several kilometres, c) absolute measurement of absorber concentration and d) independence of absorption outside of the cavity. As an important intermediate step on the way to the broadband CRD spectrometer, a monochromatic CRD spectrometer was designed, set up and characterised. To effectively couple light into the cavity, the beam parameters have to be matched to the cavity’s mode. Prerequisite of this mode matching is the knowledge of the beam parameters, which were determined experimentally. Despite this mode matching, the coupling of the light into the cavity turned out to be instable. The cause of that disturbance was systematically investigated, which let to an optimization of the system. The spectra measured with this optimized system were in very good qualitative and quantitative agreement with the expected spectra. The limit of detection of this spectrometer was determined to an absorption coefficient alpha of 10^-8 cm-1. Furthermore, isotope-selective measurements were performed. The light source of the broadband CRD spectrometer is an amplified spontaneous emission diode, which is an incoherent light source. The general functionality of the spectrometer was first tested by means of CEAS measurements (cavity enhanced absorption spectroscopy). Afterwards, the wavelength dependent ring-down signals of the empty cavity and the cavity filled with a CO2 air mixture were detected. The qualitative comparison with the expected data shows very good agreement. For the quantitative interpretation of the experimental data, a special algorithm was developed. Thereby the data measured with the presented spectrometer can be interpreted both qualitatively and quantitatively. The limit of detection of the broadband CRD spectrometer was determined to a value of alpha = 8x10^-7 cm-1. The systematic and the random error are in the range of 1 %. The presented spectrometer is a prototype. Therefore the systematic and random error will be improved by further optimization of the spectrometer.