• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 144
  • 33
  • 26
  • 8
  • 6
  • 4
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 249
  • 216
  • 47
  • 46
  • 37
  • 36
  • 32
  • 32
  • 29
  • 28
  • 27
  • 27
  • 22
  • 21
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação da concentração de metais e outros elementos de interesse em amostras de sedimentos dos estuários de Santos/São Vicente e Cananéia, Estado de São Paulo, Brasil / Metal and trace element sediment assessment from two estuarine systems: Santos/São Vicente and Cananéia, State of São Paulo, Brazil

Eduardo Paulo de Amorim 10 October 2012 (has links)
No presente trabalho foram avaliados os teores de alguns metais tóxicos como Cd, Hg e Pb, outros elementos maiores e traço em amostras de sedimentos superficiais, provenientes de dois sistemas sob diferentes graus de ação antrópica, o sistema estuarino de Santos/São Vicente e na porção sul do sistema estuarino lagunar de Cananéia, ambos no litoral do Estado de São Paulo. Foram coletados sedimentos em 16 estações no estuário de Santos/São Vicente e 13 estações no estuário de Cananéia, durante o verão e inverno de 2005 e 2006, em ambos os estuários. Foram utilizadas 3 técnicas analíticas: NAA, AAS e ICP OES. Pela técnica de ativação neutrônica (NAA) foram determinados os teores dos elementos maiores (Ca, Fe e Na), elementos traço (As, Ba, Br, Cd, Co, Cu, Cr, Cs, Hf, Rb, Sb, Sc, Ta, Th, U, Zn e terras raras La, Ce, Eu, Nd, Sm, Lu, Tb, Yb). Pela técnica de espectrometria de emissão ótica com plasma indutivamente acoplado (ICP OES), foram avaliados os teores de Al, Ba, Be, Bi, Co, Cu, Cr, Fe, Li, Mn, Mo, Ni, Sr e Zn. Pela técnica de espectrometria de absorção atômica atômica (AAS), foram determinados por forno de grafite (GF AAS) Cd e Pb, e pela técnica de geração de vapor frio (CV AAS), o Hg. As metodologias analíticas foram validadas quanto à precisão e exatidão, por meio da análise de materiais de referência certificados. Foram calculados os limites de detecção e quantificação, para cada elemento analisado, para as diferentes técnicas analíticas. Foram avaliadas também as variações espaciais, sazonais (inverno e verão) e temporais (2005 e 2006) dos metais e elementos traço nos sedimentos. No estuário de Santos/São Vicente, em geral, as concentrações de metais e elementos traço, teores de matéria orgânica e % da fração pelítica encontrados no canal de Santos (área 1), foram maiores do que na baía de Santos (área 2) e no canal de São Vicente (área 3). A área 1 sofre grande impacto das atividades industriais da região de Cubatão e do porto de Santos. Os sedimentos da estação 14 (área 3, Canal de São Vicente) apresentaram comportamento semelhante aos da área 1, sofrendo influência do polo industrial e por estar localizado em uma área de mangue. Na comparação com os valores orientadores TEL e PEL adotados pela CETESB para os metais tóxicos em sedimentos, verificou-se que a área 1 ultrapassou os limites TEL para alguns dos metais, principalmente para Hg. Os sedimentos da área 2 e da área 3 (exceto estação 14), não ultrapassaram os valores limites para a maioria dos metais analisados. Apesar dos sedimentos do estuário de Cananéia serem compostos principalmente por frações de areia, em algumas estações a fração pelítica foi bastante significativa. A partir dos resultados obtidos na região de Cananéia, observou-se que as concentrações potencialmente disponíveis dos metais Cd, Pb, Hg, Cr, Cu, Ni e Zn se encontraram abaixo dos limites estabelecidos pela legislação CONAMA 344/2004 para sedimentos e dos limites TEL e PEL, para as 3 áreas avaliadas: área 1 (Mar de Cananéia), área 2 (Baia de Trapandé) e área 3 (Mar de Cubatão). Fator de Enriquecimento (FE) e índice de geoacumulação (Igeo), ferramentas geoquímicas para avaliação da contaminação de metais e elementos traço, foram usadas para avaliar os níveis de contaminação em ambos os estuários. Aos resultados obtidos foi aplicada análise estatística multivariada e por último, os resultados foram comparados com outros dados publicados na literatura para as regiões em estudo (Santos/São Vicente e Cananéia). / This study evaluated some toxic metals such as Cd, Hg and Pb and some other major and trace elements in surface sediment samples, from two different systems under different degrees of anthropogenic actions: the estuarine system of Santos/São Vicente and the southern part of the Cananéia estuary, both on the São Paulo state coast. Sediment samples were collected in 16 stations in the Santos/São Vicente estuary and 13 stations in the Cananéia estuary, during summer and winter of 2005 and 2006, in both estuaries. Three analytical techniques were used: NAA, AAS and ICP OES. NAA was used for the quantification of major element concentration levels (Ca, Fe and Na), trace elements (As, Ba, Br, Cd, Co, Cu, Cr, Cs, Hf, Rb, Sb, Sc, Se, Ta, Th, U, and Zn and rare earths elements La, Ce, Eu, Nd, Sm, Lu, Tb, Yb). ICP OES was used for determination of the concentration levels of Al, Ba, Be, Bi, B, Cd, Co, Pb, Cu, Cr, Sn, Sr, Fe, Li, Mn, Mo, Ni, Tl, Ti, V and Zn. AAS for Cd and Pb quantification through graphite furnace (GF AAS) and Hg through cold vapor generation (CV AAS). Methodology validation according to precision and accuracy was performed by reference material analyses for the three analytical techniques used. Detection and quantification limits were calculated for each element evaluated. Seasonal variations (summer and winter), spatial and temporal (2005 e 2006) variations of metals and trace elements were also evaluated. In the Santos estuary, in general, metal and trace element concentrations , organic matter content and % of pellitic fraction found in the Santos channel (area 1) were higher than those of the Santos Bay (area 2) and São Vicente channel (area 3). Area 1 suffers high impact from industrial activities from the Cubatão region and Santos port. The sediments from station 14 (area 3, São Vicente channel), showed the same behavior of those from area 1, suffering influence from the industrial pole and located in a mangrove area. In comparison with TEL and PEL oriented values adopted by CETESB for toxic metals content in sediments, area 1 surpassed the TEL limits for some metals, mainly for Hg. Sediments from area 2 and 3 (except station 14), did not exceed the limits for most of the metals analyzed. Although the sediments from Cananéia region were composed mainly of sandy fractions, in some stations the pellitic fraction was greatly significant. From the results obtained in the region, the concentration levels of metals potentially available such as Cd, Cr, Cu, Hg, Ni, Pb and Zn were below the limits TEL and PEL oriented values and CONAMA 344/2004 resolution for the 3 areas assessed: area 1 (Cananéia sea), area 2 (Trapandé Bay) and area 3 (Cubatão sea). Enrichment Factor (EF) and Geoaccumulation index (Igeo), geochemical tools used for contamination assessment were used to evaluate the contamination level in both estuaries. Multivariate statistical analysis was applied to the results which were then compared to the results of other published studies in these regions (Santos/São Vicente and Cananéia).
22

Otimização e validação de metodologia analítica para determinação de metais e semimetais em efluentes líquidos por espectrometria de emissão óptica com plasma de argônio (ICP-OES) / Optimization and validation of analytical methodology for determination of metals and semimetals in wastewater by inductively coupled plasma optical emission spectrometry (ICP-OES)

Joyce Rodrigues Marques 24 November 2015 (has links)
Além da Resolução CONAMA 430/11 definir limites para o lançamento de efluentes, também define que os laboratórios que realizam análises ambientais devem ser acreditados pelo INMETRO e também devem ter sistema de controle de qualidade implantado. Para o atendimento destes requisitos legais, o presente trabalho visa otimizar, validar e implantar a metodologia analítica desenvolvida e aplicada no Centro de Química e Meio Ambiente (CQMA) do Instituto de Pesquisas Energéticas e Nucleares (IPEN/ CNEN SP) para a quantificação dos elementos cádmio, chumbo, cobre, prata, crômio, zinco, estanho, níquel, ferro, bário, manganês e boro em amostras de efluentes líquidos por Espectrometria de Emissão Óptica com Plasma Acoplado Indutivamente (ICP-OES). Esta metodologia é utilizada para a determinação de metais e semimetais em amostras coletadas no Programa de Monitoramento Ambiental PMA-Q do IPEN. Todo o processo de validação desta dissertação foi baseado no guia Orientativo do INMETRO DOQ-CGCRE-008 - Orientação sobre Validação de Métodos Analíticos. No estudo de seletividade verificou-se que a matriz não interfere nas curvas analíticas do método em estudo; a faixa de trabalho foi determinada com base nos valores máximos permitidos (VMP) pelas legislações ambientais vigentes (Resolução CONAMA 430/11, DE 8.468/76 e DE 15.425/80) e no histórico de dados do PMA-Q e todas as curvas analíticas apresentam comportamento linear na faixa de trabalho abrangida pelo método; os limites de detecção e quantificação do método atendem aos limites definidos pelas legislações ambientais vigentes e à precisão e exatidão necessárias; a precisão e exatidão apresentaram resultados satisfatórios para a finalidade do método analítico; além do método demonstrar-se robusto, embora seja necessário que o analista se atente à variação de alguns fatores no momento da realização das análises. Também foi possível realizar a estimativa de incerteza do método de modo que fosse alcançado nível de confiança de 95% dos resultados, foram levadas em consideração todas as etapas de preparo e análise das amostras e foi possível obter incerteza global entre 4,6% e 12,23%. Através dos resultados obtidos nos testes estatísticos e pela avaliação do analista foi possível verificar que o método desenvolvido e aplicado no CQMA é adequado para o fim pretendido. / Beyond define limits to wastewater release, CONAMA Resolution n° 430/11 also define that laboratories, which perform environmental analysis, have to be accredited by INMETRO and must have quality control system deployed. In order to meet this legal requirements, this work aims to optimize, validate and deploy the analytical methodology developed and applied at the Centre of Environmental Science and Technology (CQMA) at Nuclear and Energy Research Institute (IPEN/ CNEN - SP), to the determination of the elements: cadmium, lead, copper, chromium, zinc, tin, nickel, iron, barium, manganese and boron in wastewater samples by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES). This methodology is used to the determination of metals and semimetals in samples collected in the IPENs Environmental Monitoring Program PMA-Q. The entire process of validation in this dissertation relied on INMETRO guide DOQ-CGCRE- 008 Guidance for Validation of Analytical Methods. In the selectivity test it was possible to verify that the matrix cause no interferences in the calibration curves of the studied method; the working range determined was based on the Maximum Allowed Values (VMP) defined by the current environmental legislations (CONAMA Resolution 430/11, State Decree 8.468/76 and State Decree 15.425/80) and in the historical data from PMA-Q and all calibration curves presented linear behavior; the detection and quantification limits of this method also attend to the requirements of the current environmental legislation and to the required precision and accuracy; the precision and accuracy presented suitable results for the methodology objective; additionally, the analytical method presented satisfactory robustness, although the responsible for the test have to have attention to any instabilities in some factors. The measurement uncertainty was estimated as well, in order to obtain results with 95% of confidence, all steps of preparation and analysis of the samples were considered and was possible to reach global uncertainty between 4,6% and 12,23%. Through the results obtained in the statistics tests and the analyst evaluation, was possible to conclude that the analytical methodology developed at CQMA is adequate to the intended purpose.
23

Desenvolvimento e validação de metodologia para determinação de metais em amostras de água por espectrometria de emissão óptica com plasma de argônio (ICP-OES) / Development and validation of methodology for determination of metals in water samples by optical emission with argon plasma spectrometry (ICP-OES)

Mainara Generoso Faustino 05 November 2015 (has links)
Para atender a legislação ambiental do Conselho Nacional do Meio Ambiente (CONAMA), a Resolução CONAMA 357/2005, é necessário desenvolver metodologias que se aplicam na medição analítica de forma correta e para um controle de qualidade é necessário a aplicação da validação de metodologia. Para atender as exigências legais, o presente trabalho desenvolveu uma metodologia para a identificação de 12 elementos metálicos, tais como: Al, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na e Ni em águas, avaliando 14 pontos, sendo eles GU000-01 (23°46\'49.6\"S-46°47\'22\"0W), GU000-02 (23°45\'29.5\"S-46°46\'18.7\"W), GU000-03 (23°44\'52.2\"S-46°46\'13.6\"W), GU106-04 (23°44\'44.6\"S-46°45\'25.8\"W), GU000-05 (23°44\'57.5\"S-46°45\'24.2\"W), GU107-06 (23°45\'01.2\"S-46°43\'61.5\"W), GU108-07 (23°43\'64.7\"S-46°43\'42.3\"W), GU000-08 (23°42\'96.9\"S-46°43\'61.2\"W), GU109-09 (23°43\'04.6\"S-46°43\'34.0\"W), GU105-10 (23°42\'89.9\"S-46°44\'68.7\"W), GU108-11 (23°42\'53.4\"S-46°43\'44.9\"W), GU103-12 (23°41\'88.5\"S-46°44\'67.3\"W), GU102-13 (23°41\'58.0\"S-46°43\'57.3\"W), GU000-14 (23°40\'78.2\"S-46°43\'55.0\"W), distribuídos pela Represa Guarapiranga, situada no Estado de São Paulo, aplicando a metodologia validade, realizada com base no guia do Instituto Nacional de Metrologia, Qualidade e Tecnologia (INMETRO), Orientação sobre Validação de Métodos Analíticos - DOQ-CGCE-008. Foram avaliados os parâmetros: seletividade, faixa de trabalho/linearidade, limites de detecção e quantificação, tendência/recuperação, precisão, robustez e incerteza de medição. Foi utilizado a técnica de espectrometria de Emissão Óptica com Plasma de Argônio (ICP-OES). O teste de seletividade comprovou que a matriz não interfere nas curvas analíticas elaborada; a faixa de trabalho apresentou um comportamento linear, para as amostras com e sem a matriz de interesse, com um coeficiente de correlação (r), entre 0,9965 a 1,0; os limites de detecção e quantificação do método atendem aos valores máximos permitidos pela Resolução CONAMA 357/2005; com os testes de repetitividade e de recuperação o método demonstrou ser preciso e exato, além de robusto. Posteriormente foi estimado uma incerteza de medição do método. A incerteza expandida estimada variou entre 3 e 18% da concentração encontrada. A validação da metodologia permitiu a sua aplicação para a avaliação da distribuição dos 12 elementos, nas águas da represa Guarapiranga. Foram observados valores altos para Ca, Na e K, em todos os pontos de coletas analisados, evidenciando que são os elementos que fazem parte da característica geológica da área. Os elementos Fe e Al obtiveram valores acima da legislação nos pontos da Represa (G000-01, G000-02 e G000-03). Com os testes dos parâmetros para a validação, com os cálculos estatísticos aplicados, foi possível desenvolver e aplicar uma metodologia adequada para o uso pretendido. / To attend the environmental legislation of the National Environmental Council (CONAMA) CONAMAs Resolution 357/2005, it is necessary to develop methodologies that apply the analytical measurement correctly and to a quality control application of the methodology validation is required. To attend legal requirements, this study developed a methodology for identifying 12 metals, such as: Al, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na and Ni in water in 14 points, being them GU000-01 (23°46\'49.6\"S-46°47\'22\"0W), GU000-02 (23°45\'29.5\"S-46°46\'18.7\"W), GU000-03 (23°44\'52.2\"S-46°46\'13.6\"W), GU106-04 (23°44\'44.6\"S-46°45\'25.8\"W), GU000-05 (23°44\'57.5\"S-46°45\'24.2\"W), GU107-06 (23°45\'01.2\"S-46°43\'61.5\"W), GU108-07 (23°43\'64.7\"S-46°43\'42.3\"W), GU000-08 (23°42\'96.9\"S-46°43\'61.2\"W), GU109-09 (23°43\'04.6\"S-46°43\'34.0\"W), GU105-10 (23°42\'89.9\"S-46°44\'68.7\"W), GU108-11 (23°42\'53.4\"S-46°43\'44.9\"W), GU103-12 (23°41\'88.5\"S-46°44\'67.3\"W), GU102-13 (23°41\'58.0\"S-46°43\'57.3\"W), GU000-14 (23°40\'78.2\"S-46°43\'55.0\"W), distributed by Guarapiranga dam, in the State of São Paulo, applying the methodology of validation based on the National Institute of Metrology, Quality and Technology (INMETRO) guide, \"Guidance on Analytical Methods Validation - DOQCGCE- 008\". The parameters analyzed were: selectivity, working range/linearity, limits of detection and quantification, tendency/recovery, accuracy, robustness and measurement uncertainty. Was used the optical emission with argon plasma spectrometry (ICP-OES) technique. The selectivity test proved that the matrix does not interfere with elaborate analytical curves; the elaborate working range obtained demonstrate a linear behavior for samples with and without the matrix of interest, with a coefficient of correlation (r) between 0,9965 and 1,0; limits of detection and quantification of this method meet the maximum values allowed by CONAMA Resolution 357/2005; with repeatability of tests and recovery method proved to be precise and accurate, and robust. It was subsequently estimated uncertainty of measurement method. The estimated expanded uncertainty varied between 3 and 18% of the concentration found. The validation of the methodology allowed the application for the evaluation of the distribution of 12 elements in Guarapiranga dam waters. Were observed high values for Ca, Na and K, at every point analyzed collections, showing, which are, the elements that are part of the geological characteristic of the area. The iron and aluminum elements obtained values above the law in points Dam (G000-01, G000-02 and G000-03). With the parameters for the validation tests, with the statistical calculations applied, it was possible to develop and apply a methodology appropriate for the intended use.
24

Determinação multielementar de elementos traços em radiofármacos produzidos na Diretoria de Radiofarmácia por espectrometria de emissão por plasma / Multielemental determination of trace elements in radiopharmaceuticals produced at the radiopharmacy center using icp-oes technique

Tavares, Angélica Tamião 29 November 2013 (has links)
Os radiofármacos são preparações farmacêuticas, que contém radionuclídeo, utilizados em medicina nuclear. O objetivo desse trabalho foi estudar as concentrações de elementos químicos, principalmente metais, em amostras de radiofármacos ALBUMINA-TEC, DEX 70-TEC, DEX 500-TEC, DISIDATEC, DMSA-TEC, EC-TEC, DTPA-TEC, FITATO-TEC, GHA-TEC, MDP-TEC, MIBI-TEC, PIRO-TEC, FDG-Flúor-18, GERADOR IPEN-TEC, IODO-131 SOLUÇÃO. As análises foram realizadas em equipamento Vista MPX simultâneo ICP-OES (Agilent, Australia). A validação do método foi realizado segundo os critérios descritos na RDC n° 899: Guia para validação de métodos analíticos e bioanalíticos de 29 de maio de 2003. De acordo com a Farmacopeia Americana (USP), as impurezas elementares com potencial toxicidade devem ser quantificados. Uma proposta de revisão USP 35 introduz a técnica de espectrometria de emissão atômica para a análise de elementos. Os resultados de validação das análises no ICP-OES indicam a necesidade de controle da limpeza e manutenção do equipamento, alterações do sample uptake delay e avaliação da robustez com as linhas do Mg. As curvas analíticas e faixas de concentracões analisadas foram lineares com r > 0,99. Os resultados de DPR foram abaixo de 5%. Todos os resultados dos parâmetros avaliados estão de acordo com os estabelecidos pela ANVISA. / Radiopharmaceuticals are pharmaceutical preparations containing radionuclide used in nuclear medicine. The aim of this work was to study the concentrations of chemical elements, especially metals, in samples of radiopharmaceuticals ALBUMINA-TEC, DEX 70-TEC, DEX 500-TEC, DISIDA-TEC, DMSA-TEC, EC-TEC, DTPA-TEC, FITATO-TEC, GHA-TEC, MDP-TEC, MIBI-TEC, PIRO-TEC, FDG-FLÚOR-18, GERADOR IPEN-TEC, IODO-131 SOLUÇÃO. The analyses were carried out simultaneously in an ICP-OES Vista MPX (Agilent). The method validation was performed according to the criteria defined in RDC No. 899 : Guide for validation of analytical and bioanalytical methods for May 29, 2003 of the ANVISA. According to the U.S. Pharmacopeia (USP), the elemental impurities with potential toxicity must be quantified. A proposed revision to USP 35 introduces the technique of atomic emission spectrometry for the analysis of elements. The validation results of the ICP- OES analyzes indicated the necessary to control the cleaning and maintenance of equipment, changes in sample uptake delay and robustness evaluation with the lines of Mg. The analytical curves and concentration ranges analyzed were linear with r > 0.99. The results of DPR were below 5%. All the parameters were below the established by ANVISA .
25

Otimização e validação de metodologia analítica para determinação de metais e semimetais em efluentes líquidos por espectrometria de emissão óptica com plasma de argônio (ICP-OES) / Optimization and validation of analytical methodology for determination of metals and semimetals in wastewater by inductively coupled plasma optical emission spectrometry (ICP-OES)

Marques, Joyce Rodrigues 24 November 2015 (has links)
Além da Resolução CONAMA 430/11 definir limites para o lançamento de efluentes, também define que os laboratórios que realizam análises ambientais devem ser acreditados pelo INMETRO e também devem ter sistema de controle de qualidade implantado. Para o atendimento destes requisitos legais, o presente trabalho visa otimizar, validar e implantar a metodologia analítica desenvolvida e aplicada no Centro de Química e Meio Ambiente (CQMA) do Instituto de Pesquisas Energéticas e Nucleares (IPEN/ CNEN SP) para a quantificação dos elementos cádmio, chumbo, cobre, prata, crômio, zinco, estanho, níquel, ferro, bário, manganês e boro em amostras de efluentes líquidos por Espectrometria de Emissão Óptica com Plasma Acoplado Indutivamente (ICP-OES). Esta metodologia é utilizada para a determinação de metais e semimetais em amostras coletadas no Programa de Monitoramento Ambiental PMA-Q do IPEN. Todo o processo de validação desta dissertação foi baseado no guia Orientativo do INMETRO DOQ-CGCRE-008 - Orientação sobre Validação de Métodos Analíticos. No estudo de seletividade verificou-se que a matriz não interfere nas curvas analíticas do método em estudo; a faixa de trabalho foi determinada com base nos valores máximos permitidos (VMP) pelas legislações ambientais vigentes (Resolução CONAMA 430/11, DE 8.468/76 e DE 15.425/80) e no histórico de dados do PMA-Q e todas as curvas analíticas apresentam comportamento linear na faixa de trabalho abrangida pelo método; os limites de detecção e quantificação do método atendem aos limites definidos pelas legislações ambientais vigentes e à precisão e exatidão necessárias; a precisão e exatidão apresentaram resultados satisfatórios para a finalidade do método analítico; além do método demonstrar-se robusto, embora seja necessário que o analista se atente à variação de alguns fatores no momento da realização das análises. Também foi possível realizar a estimativa de incerteza do método de modo que fosse alcançado nível de confiança de 95% dos resultados, foram levadas em consideração todas as etapas de preparo e análise das amostras e foi possível obter incerteza global entre 4,6% e 12,23%. Através dos resultados obtidos nos testes estatísticos e pela avaliação do analista foi possível verificar que o método desenvolvido e aplicado no CQMA é adequado para o fim pretendido. / Beyond define limits to wastewater release, CONAMA Resolution n° 430/11 also define that laboratories, which perform environmental analysis, have to be accredited by INMETRO and must have quality control system deployed. In order to meet this legal requirements, this work aims to optimize, validate and deploy the analytical methodology developed and applied at the Centre of Environmental Science and Technology (CQMA) at Nuclear and Energy Research Institute (IPEN/ CNEN - SP), to the determination of the elements: cadmium, lead, copper, chromium, zinc, tin, nickel, iron, barium, manganese and boron in wastewater samples by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES). This methodology is used to the determination of metals and semimetals in samples collected in the IPENs Environmental Monitoring Program PMA-Q. The entire process of validation in this dissertation relied on INMETRO guide DOQ-CGCRE- 008 Guidance for Validation of Analytical Methods. In the selectivity test it was possible to verify that the matrix cause no interferences in the calibration curves of the studied method; the working range determined was based on the Maximum Allowed Values (VMP) defined by the current environmental legislations (CONAMA Resolution 430/11, State Decree 8.468/76 and State Decree 15.425/80) and in the historical data from PMA-Q and all calibration curves presented linear behavior; the detection and quantification limits of this method also attend to the requirements of the current environmental legislation and to the required precision and accuracy; the precision and accuracy presented suitable results for the methodology objective; additionally, the analytical method presented satisfactory robustness, although the responsible for the test have to have attention to any instabilities in some factors. The measurement uncertainty was estimated as well, in order to obtain results with 95% of confidence, all steps of preparation and analysis of the samples were considered and was possible to reach global uncertainty between 4,6% and 12,23%. Through the results obtained in the statistics tests and the analyst evaluation, was possible to conclude that the analytical methodology developed at CQMA is adequate to the intended purpose.
26

Desenvolvimento e validação de metodologia para determinação de metais em amostras de água por espectrometria de emissão óptica com plasma de argônio (ICP-OES) / Development and validation of methodology for determination of metals in water samples by optical emission with argon plasma spectrometry (ICP-OES)

Faustino, Mainara Generoso 05 November 2015 (has links)
Para atender a legislação ambiental do Conselho Nacional do Meio Ambiente (CONAMA), a Resolução CONAMA 357/2005, é necessário desenvolver metodologias que se aplicam na medição analítica de forma correta e para um controle de qualidade é necessário a aplicação da validação de metodologia. Para atender as exigências legais, o presente trabalho desenvolveu uma metodologia para a identificação de 12 elementos metálicos, tais como: Al, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na e Ni em águas, avaliando 14 pontos, sendo eles GU000-01 (23°46\'49.6\"S-46°47\'22\"0W), GU000-02 (23°45\'29.5\"S-46°46\'18.7\"W), GU000-03 (23°44\'52.2\"S-46°46\'13.6\"W), GU106-04 (23°44\'44.6\"S-46°45\'25.8\"W), GU000-05 (23°44\'57.5\"S-46°45\'24.2\"W), GU107-06 (23°45\'01.2\"S-46°43\'61.5\"W), GU108-07 (23°43\'64.7\"S-46°43\'42.3\"W), GU000-08 (23°42\'96.9\"S-46°43\'61.2\"W), GU109-09 (23°43\'04.6\"S-46°43\'34.0\"W), GU105-10 (23°42\'89.9\"S-46°44\'68.7\"W), GU108-11 (23°42\'53.4\"S-46°43\'44.9\"W), GU103-12 (23°41\'88.5\"S-46°44\'67.3\"W), GU102-13 (23°41\'58.0\"S-46°43\'57.3\"W), GU000-14 (23°40\'78.2\"S-46°43\'55.0\"W), distribuídos pela Represa Guarapiranga, situada no Estado de São Paulo, aplicando a metodologia validade, realizada com base no guia do Instituto Nacional de Metrologia, Qualidade e Tecnologia (INMETRO), Orientação sobre Validação de Métodos Analíticos - DOQ-CGCE-008. Foram avaliados os parâmetros: seletividade, faixa de trabalho/linearidade, limites de detecção e quantificação, tendência/recuperação, precisão, robustez e incerteza de medição. Foi utilizado a técnica de espectrometria de Emissão Óptica com Plasma de Argônio (ICP-OES). O teste de seletividade comprovou que a matriz não interfere nas curvas analíticas elaborada; a faixa de trabalho apresentou um comportamento linear, para as amostras com e sem a matriz de interesse, com um coeficiente de correlação (r), entre 0,9965 a 1,0; os limites de detecção e quantificação do método atendem aos valores máximos permitidos pela Resolução CONAMA 357/2005; com os testes de repetitividade e de recuperação o método demonstrou ser preciso e exato, além de robusto. Posteriormente foi estimado uma incerteza de medição do método. A incerteza expandida estimada variou entre 3 e 18% da concentração encontrada. A validação da metodologia permitiu a sua aplicação para a avaliação da distribuição dos 12 elementos, nas águas da represa Guarapiranga. Foram observados valores altos para Ca, Na e K, em todos os pontos de coletas analisados, evidenciando que são os elementos que fazem parte da característica geológica da área. Os elementos Fe e Al obtiveram valores acima da legislação nos pontos da Represa (G000-01, G000-02 e G000-03). Com os testes dos parâmetros para a validação, com os cálculos estatísticos aplicados, foi possível desenvolver e aplicar uma metodologia adequada para o uso pretendido. / To attend the environmental legislation of the National Environmental Council (CONAMA) CONAMAs Resolution 357/2005, it is necessary to develop methodologies that apply the analytical measurement correctly and to a quality control application of the methodology validation is required. To attend legal requirements, this study developed a methodology for identifying 12 metals, such as: Al, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na and Ni in water in 14 points, being them GU000-01 (23°46\'49.6\"S-46°47\'22\"0W), GU000-02 (23°45\'29.5\"S-46°46\'18.7\"W), GU000-03 (23°44\'52.2\"S-46°46\'13.6\"W), GU106-04 (23°44\'44.6\"S-46°45\'25.8\"W), GU000-05 (23°44\'57.5\"S-46°45\'24.2\"W), GU107-06 (23°45\'01.2\"S-46°43\'61.5\"W), GU108-07 (23°43\'64.7\"S-46°43\'42.3\"W), GU000-08 (23°42\'96.9\"S-46°43\'61.2\"W), GU109-09 (23°43\'04.6\"S-46°43\'34.0\"W), GU105-10 (23°42\'89.9\"S-46°44\'68.7\"W), GU108-11 (23°42\'53.4\"S-46°43\'44.9\"W), GU103-12 (23°41\'88.5\"S-46°44\'67.3\"W), GU102-13 (23°41\'58.0\"S-46°43\'57.3\"W), GU000-14 (23°40\'78.2\"S-46°43\'55.0\"W), distributed by Guarapiranga dam, in the State of São Paulo, applying the methodology of validation based on the National Institute of Metrology, Quality and Technology (INMETRO) guide, \"Guidance on Analytical Methods Validation - DOQCGCE- 008\". The parameters analyzed were: selectivity, working range/linearity, limits of detection and quantification, tendency/recovery, accuracy, robustness and measurement uncertainty. Was used the optical emission with argon plasma spectrometry (ICP-OES) technique. The selectivity test proved that the matrix does not interfere with elaborate analytical curves; the elaborate working range obtained demonstrate a linear behavior for samples with and without the matrix of interest, with a coefficient of correlation (r) between 0,9965 and 1,0; limits of detection and quantification of this method meet the maximum values allowed by CONAMA Resolution 357/2005; with repeatability of tests and recovery method proved to be precise and accurate, and robust. It was subsequently estimated uncertainty of measurement method. The estimated expanded uncertainty varied between 3 and 18% of the concentration found. The validation of the methodology allowed the application for the evaluation of the distribution of 12 elements in Guarapiranga dam waters. Were observed high values for Ca, Na and K, at every point analyzed collections, showing, which are, the elements that are part of the geological characteristic of the area. The iron and aluminum elements obtained values above the law in points Dam (G000-01, G000-02 and G000-03). With the parameters for the validation tests, with the statistical calculations applied, it was possible to develop and apply a methodology appropriate for the intended use.
27

An?lise de sedimento de fundo: uma amostragem representativa do estu?rio Potengi/RN

Dantas, A?cia Seleide 02 September 2009 (has links)
Made available in DSpace on 2014-12-17T15:41:47Z (GMT). No. of bitstreams: 1 AeciaSD.pdf: 4171408 bytes, checksum: b9c9bc4aed8af7d73b5b0b74a8b69ab1 (MD5) Previous issue date: 2009-09-02 / The aim of this study is to quantify the presence of major and minor elements in the sediments of estuary Potengi. Four georeferenced sampling points were used in the study, at which sediment samples were collected in the channel of the river and on the right and left banks. In addition, dissolved oxygen, salinity and water conductivity were taken in situ at the time of sample collection. The percentage of organic matter, determined by gravimetry, and granulometric analysis of the sediment samples were conducted in the laboratory. To quantify the major and minor elements a prior test to open the sample was conducted with standard NIST 1646? estuarine sediment to choose the best methodology to be adopted. The sediment samples were dissolved in microwaves with nitric acid and chloridric acid, according to methodology proposed by US EPA 3051?. Quantitative analyses of the elements Al, Fe, Cd, Cr, Cu, Mn, Ni, Pb and Zn were conducted by inductively coupled plasma optical emission spectrometry (ICPOES). The results showed that the partial concentrations of the elements analyzed are below average worldwide shale levels, the standard described by Turekian and Wedepohl (1961) / Esse trabalho objetiva avaliar, por meio da quantifica??o, a presen?a dos elementos maiores e menores nos sedimentos do estu?rio Potengi. Para o estudo, foram definidos quatro pontos de amostragem georeferenciados, onde em cada um deles foram coletadas amostras de sedimento na calha do rio e nas margens esquerda e direita. Al?m disso, foram realizadas medidas de pH, oxig?nio dissolvido, salinidade e condutividade da ?gua in situ no momento da coleta. Em laborat?rio foram feitas determina??es da porcentagem de mat?ria org?nica por Gravimetria e an?lise granulom?trica nas amostras de sedimento. Para quantifica??o dos elementos maiores e menores foi realizado um teste pr?vio para abertura da amostra com um padr?o de sedimento estuarino NIST 1646a para escolha da melhor metodologia a ser adotada. As amostras de sedimento foram digeridas em microondas com ?cido n?trico e ?cido lor?drico segundo metodologia proposta pela US EPA 3051A. As an?lises quantitativas dos elementos Al, Fe, Cd, Cr, Cu, Mn, Ni, Pb e Zn foram realizadas por espectrometria de emiss?o ?tica com plasma acoplado indutivamente (ICP-OES). Atrav?s destas observou-se que as concentra??es parciais dos elementos analisados est?o abaixo do folhelho padr?o tomado como m?dia mundial descritas por Turekian e Wedepohl (1961)
28

Avaliação da concentração de metais e elementos traço em amostras de sedimento do reservatório Guarapiranga, Bacia do Alto Tietê, São Paulo, Brasil / Metal and trace element sediment assessment from Guarapiranga reservoir, alto tietê basin, São Paulo, Brasil

Guilherme Moura Guimarães 15 June 2011 (has links)
O reservatório Guarapiranga está localizado na região metropolitana de São Paulo, Brasil, e é responsável pelo abastecimento de cerca de 20% das necessidades de água da população dessa região, aproximadamente 3,7 milhões de pessoas. Contudo, esse sistema tem apresentado significante degradação em sua qualidade de água, devido ao recebimento de esgotos domésticos não tratados e efluentes industriais. Nesse estudo amostras de sedimentos foram coletadas em cinco pontos ao longo do reservatório e a concentração total de alguns elementos maiores (Fe, K e Na), traço (As, Ba, Br, Co, Cr, Cs, Hf, Rb, Sb, Sc, Ta, Tb, Th, U, V e Zn) e terras raras (Ce, Eu, La, Lu, Nd, Sm, Tb e Yb) foram determinadas pela técnica de Análise por Ativação Neutrônica Instrumental (INAA). Utilizando-se a técnica de Espectrometria de Emissão Ótica com Plasma Acoplado Indutivamente (ICP OES) as concentrações dos elementos Al, Ba, Be, Ca, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Na, Ni, Pb, Ti, V e Zn foram determinadas após a digestão ácida dos sedimentos de acordo com a metodologia US EPA 3051. As determinações dos metais Cd e Pb foram feitas por espectrometria de absorção atômica com forno de grafite (GFAAS) e a de Hg total, por espectrometria de absorção atômica com geração de vapor frio (CVAAS). A validação das três metodologias analíticas, em termos de precisão e exatidão, foi feita por meio da análise de materiais de referência certificados. Os resultados obtidos por INAA foram comparados aos valores de referência do NASC (North American Shale Composite), UCC (Upper Continental Crust) e de solos coletados na região do parque da Guarapiranga. O fator de enriquecimento (FE) e o índice de geoacumulação (Igeo) foram calculados para esses dados. As concentrações dos metais obtidos por ICP OES e AAS foram comparadas aos valores orientadores TEL e PEL do Conselho Canadense de Ministros do Meio Ambiente (CCME) e adotados pela CETESB. Os resultados foram também comparados aos valores de referência regionais (VRR) de sedimentos límnicos da Bacia do Alto Tietê. A partir desses dados foi possível realizar uma avaliação do acúmulo de metais e elementos traço nos sedimentos do reservatório e verificar a possibilidade desses elementos interferirem, adversamente, na biota e na qualidade da água desse ambiente. / The Guarapiranga Reservoir, located in São Paulo metropolitan region, Brazil, is responsible for supplying about 20% of the entire populations water needs of this region or approximately 3.7 million people. However, this system has shown significant degradation in water quality, due to untreated domestic sewage and industrial effluents. In this study sediment samples were collected at five points along the reservoir and total concentration of some major (Fe, K and Na), trace (As, Ba, Br, Co, Cr, Cs, Hf, Hg, Rb, Sb, Sc, Ta, Tb, Th, U, V and Zn) and rare earth (Ce, Eu, La, Lu, Nd, Sm, Tb and Yb) elements were determined by instrumental neutron activation analysis (INAA). By inductively coupled plasma optical emission spectrometry (ICP OES) the concentrations of Al, Ba, Be, Ca, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Na, Ni, Pb, Ti, V e Zn were determined after digestion procedure following US EPA 3051 methodology. The concentrations of metals Cd and Pb were determined by graphite furnace atomic absorption spectrometry (GFAAS) and total Hg by cold vapor atomic absorption spectrometry (CVAAS). Methodology validation according to precision and accuracy was performed by reference materials analyses for the three different analytical techniques used. Multielemental results obtained by INAA were compared to NASC (North American Shale Composite), Upper Continental Crust (UCC) and soil from Guarapiranga park values. The Enrichment Factor (EF) and Geoaccumulation Index (Igeo) were also evaluated for these data. Metal concentration results by ICP OES and AAS in the samples were compared to the TEL and PEL oriented values established by the Canadian Council of Ministers of the Environment and also adopted by CETESB (Environmental Protection Agency of the São Paulo State). The results were also compared to regional reference values (VRR) of limnic sediments from the Alto Tietê Basin. From these data an assessment of metal and trace element accumulated in the sediments from the reservoir was carried out and the possibility of these elements interfering adversely on biota and water quality of this environment.
29

Acoplamento das técnicas HPLC-ICP OES para separação e identificação de metaloproteínas em castanhas de caju / Coupling of LC-ICP OES techniques for separation and identification of metalloproteins in cashew nuts

Bruno Menezes Siqueira 02 September 2016 (has links)
O objetivo desse trabalho foi demonstrar a viabilidade do acoplamento entre as técnicas de cromatografia líquida de alta eficiência com a espectrometria de emissão óptica com plasma indutivamente acoplado (HPLC - ICP OES) em um equipamento da Thermo Fisher Scientific, visando análise de especiação elementar de espécies com maiores concentrações na amostra. A identificação de espécies moleculares associadas aos elementos Cu, Fe, Mg, e Zn em amostras de castanha de caju foi adotada como modelo para comprovar tal acoplamento. Para que o ICP OES pudesse adquirir sinais de emissão ao longo de um tempo determinado, ou seja, para que o equipamento pudesse coletar um sinal transiente, fundamental para o acoplamento HPLC - ICP OES, foi necessário executar algumas modificações. Para isso, foram feitas alterações na placa eletrônica principal do equipamento, e trocada sua caixa controladora de gases. Os parâmetros instrumentais do ICP OES foram otimizados em uma série de ensaios com o intuito de estabelecer e avaliar desempenho do instrumento e a robustez do método empregado nas análises de castanha de caju. Determinações das concentrações totais de Ca, Cu, Fe, Mg, Mn, Ni, e Zn foram feitas em amostras de castanha de caju e nos materiais de referência NIST 1515 e NIST 1547, apresentando uma exatidão do método aceitável, levando-se em consideração o preparo de amostra e a medida no ICP OES. As determinações totais elementares nas amostras de castanha de caju indicaram que os teores de Ca foram de (0,04 ± 0,01) % ; Cu (26,3 ± 5,0) mg kg-1; Fe (47,9 ± 8,8) mg kg-1; Mg (0,31 ± 0,04) %; Mn (25,6 ± 3,9) mg kg-1; Ni (24,8 ± 1,9) mg kg-1; Zn (66,3 ± 2,4) mg kg-1. Para identificação de espécies moleculares associadas aos elementos Cu, Fe, Mg, e Zn, foi feita nas amostras de castanha de caju uma extração de metais e proteínas utilizando-se de uma solução extrato de NaOH 1 mol L-1. O extrato ainda foi submetido à uma etapa de clean-up, com precipitação das proteínas com acetona e ressupenção das mesmas com tampão Tris-HCl, pH 7,4. As proteínas e metais ressupensos em tampão foram analisados no sistema HPLC ICP OES, em que a separação cromatográfica ocorreu através de uma coluna de exclusão por tamanho (SEC), a detecção molecular através do detector UV-Vis do HPLC, e a detecção elementar através do ICP OES. As espécies moleculares identificadas estão no intervalo de massa molecular compreendido entre 2 e 177 kDa, sendo que Cu, Fe e Zn apresentam associação com essas espécies moleculares. Foram monitorados ainda, no ICP OES, os sinais de intensidade de emissão de P e S. Esses elementos também apresentaram associação com espécies moleculares com peso molecular entre 2 e 177 kDa, sugerindo que essas espécies se tratam de metaloproteínas. / The aim of this study was to demonstrate the capability of coupling between liquid chromatography techniques of high efficiency with the optical emission spectrometry with inductively coupled plasma (HPLC - ICP OES) in an equipment of Thermo Fisher Scientific, aiming elemental speciation analysis of species with higher concentrations in the sample. The identification of molecular species associated with elements Cu, Fe, Mg and Zn in cashew nuts samples was adopted as a model to prove such coupling. For ICP OES could get emission signal through a certain time, so that the equipment could collect a transient signal, critical to the HPLC coupling - ICP OES, it was necessary to perform some modifications in the instrument. For this, changes were made to the main electronic board of the equipment and also changed their gas controller box. The instrumental parameters of the ICP OES were optimized in a series of tests in order to establish and evaluate performance of the instrument and the robustness of the method employed in cashew nut analysis. Determination of the total concentration of Ca, Cu, Fe, Mg, Mn, Ni and Zn were made in cashew sample and reference materials NIST 1515 and NIST in 1547, with an accuracy acceptable method, taking into account the sample preparation and measurement by ICP OES. The elemental total determinations in cashew nut samples indicated that Ca were (0.04 ± 0.01)%; Cu (26.3 ± 5.0) mg kg-1; Fe (47.9 ± 8.8) mg kg-1; Mg (0.31 ± 0.04)%; Mn (25.6 ± 3.9) mg kg-1; Ni (24.8 ± 1.9) mg kg-1; Zn (66.3 ± 2.4) mg kg-1. For the identification of molecular species associated with the elements Cu, Fe, Mg, and Zn was performed on samples of cashew nuts an extract of metals and proteins using an extract solution of NaOH 1 mol L-1. The extract was further subjected to one-step of clean-up with protein precipitation with acetone following by a resuspension with Tris-HCl buffer, pH 7.4. Proteins and metals resuspended in buffer, were analyzed in the HPLC - ICP OES system, wherein the chromatographic separation took place by a size exclusion column (SEC), the molecular detection by UV-Vis detector of HPLC, and elemental detection by ICP OES. The molecular species were identified in the molecular weight range between 2 and 177 kDa, and Cu, Fe and Zn are associated with these molecular species. Were also monitored in the ICP OES, P and S emission intensity signals. These elements also associated with molecular species having a molecular weight between 2 and 177 kDa, suggesting that this species are metalloproteins.
30

Otimização de métodos para a determinação de P, Pb e Si em gasolinas por ICP-OES / Optimization of methods for the determination of Pb, Si and P in gasolines by ICP-OES

Sandra Patricia de Andrade Mariano Santos 08 December 2017 (has links)
O objetivo deste trabalho foi desenvolver métodos para a determinação simultânea de Pb, Si e P em gasolinas por ICP OES em conformidade com a Agência Nacional de Petróleo (ANP). O mercado da gasolina no Brasil é regulado pela Agência Nacional do Petróleo (ANP) e pela Lei Federal 9.478/97 (Lei do Petróleo) e, conforme Resolução ANP n°40, de 25.10.2013, a determinação de chumbo é exigida quando houver suspeita de contaminação. O chumbo era adicionado, desde 1922 para elevar o índice antidetonante da gasolina, mas devido a sua toxicidade foi mundialmente substituído. A determinação do silício passou a ser exigida em 1 de Janeiro de 2014 nas gasolinas, porque frações leves contaminadas com silício, quando usadas como combustíveis, podem gerar problemas aos motores automotivos, uma vez que os aditivos antiespumantes, a base de oligômeros contendo silício, são adicionados durante o processo de refino. O fósforo é um aditivo estimulante da extração do petróleo, sua determinação também é exigida quando houver suspeita de contaminação, pois concentrações acima do limite máximo podem desativar os catalisadores dos carros. No preparo de amostras foram utilizadas duas estratégias, a primeira diluição da gasolina com solventes orgânicos 10% da gasolina e 90% de Premisolv-Constan, com a vantagem da int rodução direta, porém necessita câmara refrigerada e fluxo de O2. E preparo da amostra por emulsão tipo óleo/água (O/W), preparada utilizando 1 mL de gasolina com 3 mL de surfactante Tergitol TMN-6® (20% m v-1), o qual foi escolhido entre 4 surfactantes (TritonTM X-100,TritonTM X-114, TergitolTMTMN-6 e TergitolTM 15-S-9) por ter apresentado melhor desempenho na formação da emulsão e menor branco analítico. Essa segunda estratégia apresentou vantagens em relação a primeira, pois reduz a introdução da matéria orgânica para 10% e dispensa o uso de câmara especial e fluxo de O2. As amostras foram analisadas com a construção de curvas de adição padrão a fim de eliminar os efeitos de matriz. Também foram analisadas amostras dopadas com padrão orgânico nas concentrações dos limites estabelecidos pela Resolução ANP. As recuperações foram de 86% a 98% para Pb, 90% a 106% para Si e 86% a 110% para P. Portanto o método desenvolvido demonstrou a possibilidade da determinação simultânea de Si, Pb e P nos limites estabelecidos pela legislação (Pb = 5 mg LTM-1, P = 1,3 mg L-1 e Si limite máximo ainda não estabelecido) e está de acordo com a Química Verde e Gestão de Saúde Meio Ambiente e Segurança. / The objective of this work was to develop methods for the simultaneous determination of Pb, Si and P in gasoline by ICP-OES in accordance with the National Petroleum Agency (ANP). The Brazilian gasoline market is regulated by the National Petroleum Agency (ANP) and Federal Law 9.478 / 97 (Petroleum Law) and according to ANP Resolution No. 40, dated 10.25.2013, the determination of lead is required when there is suspected contamination. Lead was added since 1922 to raise the antiknock index of gasoline, but because of its toxicity it has been worldwide replaced. The determination of silicon was required on 1 January 2014 in gasoline. Light fractions contaminated with silicon, when used as fuel, can cause problems for automotive engines, since antifoaming additives, based on silicon-containing oligomers, are added during the refining process. Phosphorus is a stimulating additive to petroleum extraction; its determination is also required when contamination is suspected, as concentrations above the upper limit can deactivate the catalysts of the cars. In the preparation of samples, two strategies were used, the first dilution of gasoline with organic solvents 10% of the gasoline and 90% of Premisolv-Constan, with the advantage of direct introduction, however, requires refrigerated chamber and O2 flow. Preparation of the sample by oil / water (O / W) emulsion, using 1 ml of gasoline with 3 ml of Tergitol TMN-6 surf surfactant (20% m v-1), which was chosen among 4 surfactants (TritonTM X-100, TritonTM X-114, TergitolTM TMN-6 e TergitolTM 15-S-9), because it showed better performance in the formation of the emulsion and lower analytical blank. This second strategy presents advantages over the first one because it reduces the introduction of the organic matter to 10% and dispenses with the use of special chamber and O2 flow. Samples were analyzed by constructing standard addition curves to eliminate matrix effects. We also analyzed doped samples with organic standards in the concentrations of the limits established by ANP Resolution. The recoveries were 86% to 98% for Pb, 90% to 106% for Si and 86% to 110% for P. Therefore, the method developed demonstrated the possibility of simultaneous determination of Si, Pb and P within the limits established by the legislation (Pb = 5 mg L-1, P = 1,3 mg L-1 and Si maximum limit not yet established) and is in accordance with the Green Chemistry and Health Management Environment and Safety.

Page generated in 0.0414 seconds