• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 176
  • 40
  • 16
  • 4
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 245
  • 245
  • 56
  • 56
  • 49
  • 39
  • 38
  • 32
  • 29
  • 27
  • 27
  • 24
  • 24
  • 23
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
231

A influência da via aérea superior no uso do aparelho intraoral de avanço mandibular para o tratamento da síndrome da apneia obstrutiva do sono / The influence of upper airway in use of mandibular advancement intraoral device for treatment of obstructive sleep apnea syndrome

Prescinotto, Renato [UNIFESP] 27 April 2011 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:49:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-04-27. Added 1 bitstream(s) on 2015-08-11T03:26:08Z : No. of bitstreams: 1 Publico-12669.pdf: 1362463 bytes, checksum: 68544347c989279806cb3905a07b4791 (MD5) / Introdução: O tratamento escolhido para os pacientes com Síndrome da apneia obstrutiva do sono (SAOS) tem sido o uso dos aparelhos de pressão aérea positiva contínua (CPAP), especialmente nos casos moderados a graves, porém, nas ocorrências mais leves, os aparelhos intraorais de avanço mandibular (AIO) podem ser indicados. Existem trabalhos na literatura correlacionando a presença de alterações anatômicas na via aérea superior (VAS) com a adesão ao CPAP, contudo, em relação ao sucesso e à adesão aos AIOs, a literatura é escassa Objetivos: Comparar os achados de uma avaliação sistemática da VAS quanto ao sucesso e à adesão ao tratamento com AIO de pacientes com SAOS. Método: Foram avaliados 28 pacientes adultos com SAOS leve a moderada e com indicação de tratamento com AIO. Os pacientes foram submetidos a questionários de sono e de queixas nasais, exame físico antropométrico e da VAS e polissonografia, antes e após 120 dias de uso do AIO. Ao término do protocolo, os pacientes foram divididos quanto ao sucesso e ao insucesso e quanto à adesão - boa e má adesão -, e os achados foram comparados entre os grupos. Foi considerado sucesso à terapia os pacientes que reduziram o índice de apneia e hipopneia (IAH) em 50%, estando abaixo de 10 eventos por hora; e o critério de boa adesão foi o uso do AIO em 90% das noites na última semana, conforme diário de uso do AIO. Resultados: A média de idade foi de 48,8±11,3 anos, sendo 32,1% do sexo masculino e 67,9% do sexo feminino. O sucesso ao tratamento com AIO foi de 64,3%, e a adesão foi de 60,7%. Quanto à adesão, não houve significância estatística em nenhum dos parâmetros de VAS analisados. Em relação ao sucesso, houve um predomínio de pacientes com alteração nasal nos pacientes com insucesso (p=0,04), às custas principalmente de desvios septais obstrutivos (graus II e III) (p=0,04). Conclusões: O sucesso do tratamento com AIO foi significativamente menor nos pacientes com alterações nasais, o que não foi observado em relação à adesão. / Introduction: The treatment of choice for patients with obstructive sleep apnea syndrome (OSAS) has been the use of continuous positive airway pressure devices (CPAP), especially in moderate to severe cases, but in milder cases, the mandibular advancement devices (MAD), may be indicated. There are studies in the literature correlating the presence of anatomical abnormalities in upper airway (UA) with adherence to CPAP, but about the success and adherence of MAD the literature is scarce. Objectives: To compare the findings of a systematic evaluation of the UA on the success and adherence to treatment with MAD of patients with OSAS. Methods: We studied 28 adult patients with mild to moderate OSAS referred for treatment with MAD. The patients underwent sleep questionnaires and nasal symptoms, anthropometric and upper airway examination and polysomnography before and after 120 days using MAD. At the end of the protocol, patients were divided about the success (success and failure) and to the adherence (good adherence and poor adherence) and the findings were compared between groups. Was considered successful therapy the patients who reduced the apnea-hypopnea index (AHI) in 50%, being below 10/events per hour and the criterion for good compliance was the use of MAD in 90% of nights last week (Daily use of AIO). Results: The mean age was 48.8 ± 11.3 years, and there were 32.1% males and 67.9% female. Successful treatment with MAD was 64.3% and good adherence was 60.7%. About the adherence, there was no statistical significance in the parameters of UA analyzed. About the success, there was a predominance of patients with nasal alterations in patients with failure (p = 0.04), mainly at the expense of obstructive septal deviation (grades II and III) (p = 0.04). Conclusions: The sucess of treatment with AIO was significantly lower in patients with nasal alterations, which was not observed with regard to adherence. / TEDE / BV UNIFESP: Teses e dissertações
232

Eficácia de exercícios mandibulares para disfunção temporomandibular em pacientes com síndrome da apnéia obstrutiva do sono em tratamento com aparelho intra-oral / Efficacy of mandibular exercices as support therapy for temporomandibular disorders in patents with sleep apnea syndrome treated with oral appliance

Cunali, Paulo Afonso [UNIFESP] 28 February 2009 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:50:00Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-28 / Introdução: Os estudos que contra-indicam o uso de um aparelho intra-oral (AIO) para tratamento da Síndrome da Apnéia Obstrutiva do Sono (SAOS) na presença de sinais e/ou sintomas da disfunção temporomandibular (DTM), ou que relatam o abandono ou suspensão do seu uso devido à dor causada pela DTM, não seguiram o mesmo critério de diagnóstico para a DTM. Desde que a qualidade de vida dos indivíduos com SAOS e DTM fica ainda mais comprometida devido à presença de ambas as síndromes, é importante um diagnóstico seguro e um tratamento eficaz para a DTM. Entre os tratamentos, os exercícios mandibulares são tidos como terapias de suporte (TS) para as DTM. Objetivo: Avaliar, em indivíduos com SAOS e DTM, a eficácia de uma terapia de suporte com exercícios mandibulares para a DTM, na redução da dor, na melhora da qualidade de vida, com o fim de alcançar o aumento da adesão ao tratamento com o AIO. Casuística e Métodos: Todos os pacientes foram avaliados no início, e após 120 dias de uso do AIO com: Questionário do sono de Fletcher e Lucket, Escala de Sonolência de Epworth, Inventário de qualidade de vida SF 36, polissonografia, diário de sono e de uso do AIO, avaliação clínica e radiográfica dos dentes, das estruturas ósseas e exame da ATM pelos critérios diagnósticos de DTM (RDC). Os pacientes foram aleatoriamente divididos em 2 grupos: terapia de suporte para DTM (TS) e terapia placebo (TP). Resultados: De 87 pacientes com diagnóstico de SAOS leve à moderada e encaminhados para uso de AIO, 45 tiveram diagnóstico confirmado pelo RDC de (DTM). Vinte e nove pacientes cumpriram os 120 dias de tratamento (15 pacientes no grupo da TS, e 14 no grupo da TP). Os pacientes do grupo TS mostraram melhora significativa nas queixas do sono, e melhora em maior número de domínios da qualidade de vida quando comparados com o grupo de TP. No decorrer do avanço do AIO foi observado um número significativamente maior de pacientes com dor persistente no grupo da TP em comparação com o grupo da TS. Houve redução da intensidade da dor no grupo de TS comparado ao grupo TP. Após o avanço do AIO, foi observada maior adesão ao uso do AIO no grupo da TS. Conclusão: A TS com exercícios mandibulares resultou em melhora significativa na qualidade de vida e na qualidade do sono nos pacientes com SAOS e DTM tratados com AIO, além de ter sido efetiva na redução da dor e no aumento na adesão ao tratamento com o AIO. / Introduction: The studies that contra-indicate the use of an oral appliance (OA) for the treatment of Obstructive Sleep Apnea Syndrome (OSA) in the presence of signs and / or symptoms of temporomandibular disorders (TMD), or that report abandonment or suspension of their use due to pain caused by TMD, did not follow the same diagnosis criteria for TMD. Since the quality of life of individuals with OSA and TMD is further compromised by the presence of both syndromes, it is essential a assure diagnosis and a effective treatment for TMD. Among the treatments, the jaw exercises are considered as a supportive therapy (ST) in TMD. Objective: To assess the effectiveness of mandibular exercises, with support therapy for TMD in subjects with OSA and TMD considering the in reduction of pain, improved of the quality of life, and the compliance to treatment with the OA. Patients and Methods: All patients were evaluated prior and to 120 days after the use of the OA by means Fletcher & Lucket sleep questionnaire, the Epworth Sleepiness Scale, the SF-36 Inventory of quality of life, polysomnography, sleep and daily usage OA, clinical and radiographic evaluation of teeth and bone structure, and exam to observed sings and/or symptoms for TMD by the RDC/TMD criteria. The patients were randomized in two groups: support therapy (ST) and placebo therapy (PT). Results: Forty-five out of the 87 patients who were diagnosed with mild to moderate OSA referred to the use of the OA had their diagnosis confirmed by the RDC/TMD. Twenty-nine of those patients completed the 120 days treatment (15 patients in the ST group and 14 in the PT group). Patients in the ST group showed a significant improvement in their sleep complaints and improvement in a higher number of life quality domains when compared to the group of PT. As advances were made in OA positioning a significantly higher number of patients with persistent pain was observed in the PT group, in comparison to the ST group. There was reduction of pain intensity in the ST group compared to PT group. After advancement of the OA, higher compliance to the use of OA was observed in the ST group than in the PT group. Conclusion: Support Therapy with mandibular exercises showed significant improvement in quality of life and quality of sleep in patients with OSA and TMD who were treated with OA, being also effective in reducing pain and the increase the compliance to the OA treatment. / TEDE / BV UNIFESP: Teses e dissertações
233

Estabilidade da correção da Classe II, 1ª divisão com o aparelho Bionator de Balters associado ao aparelho fixo / Stability of the correction of the Class II, division 1 malocclusion with the Balters Bionator associated to fixed appliances

Manoela Fávaro Francisconi 25 February 2011 (has links)
Recursos ortopédicos e ortodônticos, utilizados de forma associada, têm se mostrado uma opção terapêutica eficiente no tratamento da má oclusão de Classe II, 1ª divisão desde que o paciente ainda apresente um potencial de crescimento favorável. Entretanto, as alterações nas relações esqueléticas, dentárias e tegumentares só podem ser consideradas satisfatórias caso permaneçam estáveis. Assim, este trabalho teve o propósito de avaliar cefalometricamente e por meio de modelos de estudo, a estabilidade das alterações decorrentes do tratamento com o aparelho Bionator de Balters, seguido do aparelho fixo, após um período médio de 10 anos. O grupo experimental compreendeu 23 pacientes que foram avaliados em três fases: inicial (T1), final (T2) e longo tempo pós-tratamento (T3). Foram avaliadas as telerradiografias em norma lateral (inicial, final e longo tempo pós-tratamento), totalizando 69 telerradiografias, e foram mensurados 69 modelos de estudo, avaliados nas fases previamente descritas, através do índice PAR. Também calculou-se a diferença entre o PAR inicial e o PAR final, a % de melhora obtida com esta terapia e a % de recidiva, ambas através do índice PAR. As variáveis analisadas foram comparadas por meio da análise de variância (ANOVA) para medidas repetidas e o teste de comparações múltiplas de Tukey. A terapia estudada não propiciou alterações no desenvolvimento maxilar. Observou-se um aumento na protrusão mandibular, bem como um maior incremento no comprimento efetivo da mandíbula. A relação maxilomandibular foi corrigida, notou-se uma melhora na convexidade facial, com a diminuição do ângulo ANB. Alterações significantes no padrão de crescimento craniofacial não foram observadas. Verificou-se, através da variável FMA e no período de longo tempo pós-tratamento, uma rotação do plano mandibular no sentido anti-horário. O posicionamento vertical da maxila (SN.PP) também não se alterou. Os incisivos superiores sofreram lingualização e retrusão. Os primeiros molares superiores mostraram um pequeno aumento no sentido vertical semelhante ao fisiológico, que ocorre pelo processo de flutuação normal. Em contrapartida, os incisivos inferiores sofreram vestibularização e protrusão. Os primeiros molares inferiores, por sua vez, apresentaram um deslocamento no sentido vertical (extrusão) e horizontal (mesialização), contribuindo, assim, para a correção da má-oclusão de Cl II. O tratamento também foi efetivo em corrigir os respasses, horizontal e vertical, bem como a relação molar. O ângulo nasolabial não foi afetado pelo tratamento, mostrando que os aparelhos ortopédicos não afetam substancialmente esta variável. Além disso, é de suma importância, ressaltarmos que, as alterações obtidas, com o tratamento realizado, permaneceram estáveis no período de longo tempo pós-tratamento; demostrando, dessa maneira, a efetividade da terapia selecionada. Finalmente, na análise dos modelos de estudo, os valores do índice PAR sofreram uma redução estatisticamente significante e permaneceram estáveis no período de longo tempo pós-tratamento. A porcentagem de melhora obtida com esta terapia foi de 81,78% e a de recidiva foi de 4,90%. Esses dados refletem que o Bionator de Balters, associado ao aparelho fixo, é uma efetiva alternativa para o tratamento da má-oclusão de Cl II, 1ª divisão. / Orthopedic and orthodontic approaches, used in an associated way, are being considered an efficient therapeutic option for the treatment of the Class II, division 1 malocclusion when the patient still presents a favorable growth potential. However, changes in skeletal, dental and soft tissue relationships only can be considered satisfactory if they remain stable. This study aimed to evaluate, cephalometrically and in dental casts, the stability of the changes resulting from the treatment with the Balters Bionator followed by the fixed appliances, after a mean period of 10 years. The experimental group comprised 23 patients who were evaluated in three stages: initial (T1), final (T2) and long-term posttreatment (T3). A total of 69 lateral cephalograms (initial, final and long-term posttreatment) were evaluated and also 69 dental casts were measured, in the stages previously described, using the PAR index. Furthermore, the difference between initial PAR and final PAR, the percentage of obtained improvement with the therapy and the percentage of relapse were calculated, using the PAR index. Evaluated variables were compared by the analysis of variance (ANOVA) for repeated measures and Tukey test. The studied therapy did not provide changes in maxillary development. An increase in mandibular protrusion, as well as a greater increase in effective length of the mandible, was observed. The maxillomandibular relationship was corrected, and an improvement in the facial convexity was observed, with a decrease of the ANB angle. Significant changes in craniofacial growth were not observed. The analysis of the FMA variable and of the long-term posttreatment revealed a rotation of the mandibular plane in a counterclockwise direction. The vertical positioning of the maxilla (SN.PP) also did not change. The maxillary incisors presented a palatal inclination and retrusion. The maxillary first molars showed a small increase in the vertical direction, similar to the physiological one, which occurred by the normal fluctuation process. In contrast, the mandibular incisors presented a buccal inclination and protrusion. The mandibular first molars showed a displacement in the vertical (extrusion) and horizontal (mesial) direction, which contributed to the correction of the Class II malocclusion. The treatment was also effective in correcting the overbite and overjet, and the molar relationship. The nasolabial angle was not affected by treatment, showing that orthopedic appliances did not significantly affect this variable. Finally, the analysis of the dental casts showed that the values of the PAR index presented a statistically significant reduction and remained stable at the long-term posttreatment. The percentage of improvement obtained with this therapy was of 81.78% and the percentage of relapse was of 4.90%. These data denote that Balters Bionator associated to the fixed appliances is an effective alternative for the treatment of the Class II, division 1 malocclusion.
234

Avaliação de escova ultrassônica em pacientes sob terapia ortodôntica. Estudo in vitro, clínico e microbiológico /

Costa, Mauricio Ribeiro. January 2007 (has links)
Orientador: Rosemary Adriana Chiérici Marcantonio / Banca: Rodrigo Otávio Citó Cesar Rêgo / Banca: Sheila Cavalca Cortelli / Banca: Márcio Zaffalon Casati / Banca: Luis Geraldo Vaz / Resumo: O objetivo do estudo foi avaliar o efeito de uma escova ultrassônica, comparada a uma elétrica e a uma manual, sobre os parâmetros clínicos periodontais e microbiológicos de adolescentes sob terapia ortodôntica com aparelhos fixos. Paralelamente, foi avaliada a diminuição da força adesiva de braquetes ortodônticos, fixados a dentes humanos extraídos, após o uso de uma escova dentária ultrassônica comparada a uma escova elétrica. Material e Método: Para o experimento in vivo, 21 indivíduos (15,2l1,7) que utilizavam aparelhos fixos há mais de um ano foram divididos em três grupos de acordo com a seqüência de uso das escovas (crossover). Os pacientes usaram cada escova por um período de 30 dias, com intervalos de 15 dias entre as mesmas (washout). Amostras de saliva e placa bacteriana foram coletadas para realização de cultura microbiológica de Streptococcus grupo mutans e técnica de Checkerboard DNA-DNA Hybridization, respectivamente. No experimento in vitro, braquetes ortodônticos foram colados a superfície mais plana de quarenta e cinco dentes humanos extraídos. Posteriormente, os corpos de prova foram divididos em grupos de acordo com a escova a ser utilizada. Após o procedimento de escovação, a resistência adesiva foi avaliada em uma maquina de ensaios mecânicos. Resultado: Uma diferença significante no índice de placa (p<0,05) foi observada após o uso de escova ultrassônica nas superfícies vestibulares (10,32% pré e 3,96% pós-escovação). Da mesma forma, após o uso das escovas ultrassônicas e elétricas, as contagens de Streptococcus grupo mutans diminuíram significativamente (técnica de cultura microbiana - p<0,05). A técnica Checkerboard DNA-DNA hybridization apontou uma redução nos níveis de T. forsythia após o uso da escova elétrica e das espécies S. noxia, S. sanguinis... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study compared the efficacy of an ultrasonic toothbrush for the reduction of plaque, gingival inflammation, and levels of bacteria in relation to an electric and a manual toothbrush. In addition, it was evaluated the effect of brushing with both an ultrasonic and electric toothbrush on the bond strength of orthodontic brackets bonded to extracted human teeth. Material and method: Twenty-one patients (mean 15.2l1.7 years) with orthodontic appliances were randomly divided into three groups according to the sequence of brush usage (crossover study). The subjects used each assigned brush for a period of 30 days, followed by an interval of 15 days (washout) during which they returned to their regular toothbrushes and dental floss used in accordance with the monthly instructions of the orthodontist given prior to the study. During each visit, participants received a periodontal evaluation and samples of saliva and subgingival plaque were collected for microbiological tests (Streptococcus mutans culture and DNA-DNA Checkerboard Hybridization). For in vitro evaluation, individual orthodontic brackets were bonded to the smoothest surface of forty-five teeth. The test specimens were randomly distributed into three groups according to the toothbrush to be used. After completing the brushing stage, the test specimens were taken to the mechanical assay machine for a shearing test. Results: The ultrasonic brush group presented significant improvement in the reduction of visible plaque on the buccal surfaces (10.32% against 3.96%). The counts of S. mutans decreased in the electric and ultrasonic groups (culture test - p<0.05). The DNA-DNA Checkerboard hybridization technique showed that the counts of T. forsythia decreased significantly after a month of electric brush usage. Furthermore, in the manual group, S. noxia, S. sanguinis and P. melaninogenica counts also decreased... (Complete abstract, click electronic access below) / Doutor
235

Application of zirconium-coated titanium wires as restorative orthodontic materials

Ali, Khaled Abedela Mahdi January 2013 (has links)
Thesis submitted in fulfillment of the requirements for the degree Magister of Technology: Dental Technology In the Faculty of Health & Wellness Sciences At the Cape Peninsula University of Technology 2013 / Orthodontic archwires are made from different alloys. It is now possible to match phases of treatment with orthodontic archwires according to its mechanical properties. On this basis, the titanium molybdenum alloys (TMA) in its beta phase have an excellent combination of strength and flexibility when used as archwires to apply biomechanical forces that affect tooth movement. It has recently gained increased popularity in orthodontic treatment. There are, however, disadvantages associated with the use of orthodontic archwires, such as high surface roughness, which increases friction at the archwire-brackets interface during the sliding process. The surface roughness of dental materials is of utmost importance. Properties such as desirable tensile strengths, load deflection, hardness and low modulus of elasticity and resistance against corrosion & wear determine the area of the contact surface, thereby influencing the friction. The main object of this study was to improve the strength and surface roughness of the beta-titanium orthodontic archwires (β-Ti III) and timolium archwires (TIM), taking into account of retention of the archwires strength. The following tasks were performed. Layers of Zr were deposited on the β-Ti archwires and compared with the archwire strength before and after Zr deposition. The structure of selected archwires and its composition and surface roughness was investigated before and after Zr deposition, using scanning electron microscopy (SEM) and atomic force microscopy (AFM). The force of selected archwires before and after deposition with layers of Zr by Hounsfield deflection testing was studied. Two commercially available orthodontic archwires were used in this study, namely, β-Ti III and TIM orthodontic archwires. The archwires were cut into 25 mm long specimens. In this study, the electron beam-physical vapour deposition (EB-PVD) technique was applied to deposit pure Zr (thicknesses of 5, 10, 25 and 50 nm) on selected archwires and the effects thereof were investigated using AFM, SEM and the Hounsfield deflection test. Results of SEM and AFM analysis and deflection tests showed significant differences between Zr-coated archwires compared with uncoated archwires. Zr-coated archwires (5, 10, 25 and 50 nm depositions) had reduced surface roughness compared with uncoated archwires. A high load deflection rate was exhibited by the coated β-Ti III archwires and a low load deflection rate was exhibited by the coated TIM archwires. There was a difference in load deflection rate between the coated and uncoated archwires. Deposition of 5, 10, 25 and 50 nm Zr on both types of β-Ti orthodontic archwires is recommended for even sliding mechanics due to resulting reduced surface roughness with a good load deflection rate compared with uncoated β-Ti orthodontic archwires. KEYWORDS Surface roughness Zirconium Titanium Deflection test Beta titanium orthodontic archwires Orthodontic archwires alloys Coated materials Electron beam-physical vapour deposition Scanning electron microscopy Atomic force microscopy
236

Avaliação clínica e microbiológica periodontal de crianças e adolescentes sob terapia ortodôntica com aparelhos fixos ou removíveis /

Rêgo, Rodrigo Otávio Citó César. January 2004 (has links)
Orientador: Joni Augusto Cirelli / Banca: José Eduardo Cezar Sampaio / Banca: Ary dos Santos Pinto / Banca: Maria Mônica Studart Gurgel Mendes Moreira / Banca: Márcia Pinto Alves Mayer / Resumo: O objetivo deste estudo foi avaliar os parâmetros clínicos e microbiológicos periodontais de crianças e adolescentes sob terapia ortodôntica com aparelho fixo ou removíveis. Trinta indivíduos (14,5l1,7 anos - Grupo FIX) que utilizavam aparelhos fixos e 18 que utilizavam aparelho extra bucal removível ou placa de Hawley há pelo menos 6 meses (9,6 l 1,5 anos - Grupo REM) foram comparados a dois grupos controle, constituídos por indivíduos da mesma idade (14,2 l 1,7 anos - Grupo C-FIX e 9,3 l 1,9 anos - Grupo C-REM) que não utlizavam esses dispositivos. Foi analisada a presença de placa bacteriana visível (IP), sangramento gengival (IG), profundidade de sondagem (PS) e perda de inserção clínica (PIC). Amostras de placa bacteriana subgengival foram coletadas e analisadas por meio de sondas de oligonucleotídeos para A. actinomycetemcomitans (Aa), C. rectus, Capnocytophaga sp. E. corrodens, F. nucleatum, F. vincentii, M. micros, Neisseriaceae., P. gingivalis, P. intermedia, espiroquetas, T. forsythensis e Treponema sp. Diferenças significantes (p<0,05) foram observadas entre os grupos FIX e C-FIX quanto aos parâmetros IP (66,8% e 47,7%), IG (43% e 15,6%), e para as prevalências de todas as bactérias avaliadas, exceto as da familia Neisseriaceae. Entre dentes bandados e seus análogos no grupo controle foram encontradas diferenças significantes para os parâmetros PV (80,3% e 58,8%), SM (64,3% e 20,6%) e PS (2,9 mm e 2,5 mm), respectivamente. Entre os grupos REM e C-REM, essas diferenças também foram observadas para IP (58,7% e 14,3%) e IG (19,8% e 8,8%) e para as prevalências de Aa, C. rectus, E. corrodens, Neisseriaceae e espiroquetas. Entre os dentes retentores de grampo e seus análogos no grupo controle verificou-se diferenças significantes para IP (77,8% e 31,3%). Não foi verificado aumento da PS associado a PIC. Também foi avaliada a... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The purpose of this study was to compare clinical and microbiological parameters in children and adolescents with and without fixed or removable orthodontic appliances. Thirty subjects (mean age 14.5l1.7 years) treated with fixed appliances and 18 treated with removable appliances for at least 6 months were selected as test groups, FIX and REM, respectively. The control groups were comprised of 30 subjects (mean age 14.2l1.7 years - Group C-FIX) and 18 subjects (mean age 9.3l1.9 years - Group C-REM) that did not receive orthodontic treatment. Clinical evaluations were made for plaque index (PI), gingival index (GI), probing depth (PD) and clinical attachment loss (CAL). Subgingival plaque samples were collected from the patients and analyzed by oligonucleotide probes for the presence of A. actinomycetemcomitans (Aa), C. rectus, Capnocytophaga sp. E. corrodens, F. nucleatum, F. vincentii, M. micros, Neisseriaceae., P. gingivalis, P. intermedia, spirochetes, T. forsythensis and Treponema sp. Additionally, two subgingival dental plaque samples from one subject of each test group were further analyzed by cloning and sequencing the amplified 16S rDNA. Significant differences were noted between FIX and C-FIX for PI (66.8% versus 47.7%), GI (43.8% versus 15.6%) and between the banded teeth in the FIX group and the analogous teeth in the C-FIX group for PI (80.3% versus 58.8%), GI (64.3% versus 20.6%) and PD (2.9 mm versus 2.5 mm). Significant differences were noted between FIX and C-FIX for all targeted bacteria but Neisseriaceae. Results: Significant differences were also noted between REM and C-REM for PI (58.7% versus 14.3%) and GI (19.8% versus 8.8%) and between the clasped teeth in the test group and the analogous teeth in the control group for PI (77.8% versus 31.3%). Significant differences were noted between the REM and C-REM for Aa... (Complete abstract, click electronic address below). / Doutor
237

"Estudo dos efeitos dos lacebacks ativos e passivos na biomecânica da fase de nivelamento utilizando-se a técnica MBT" / Study of the effects of active and passive lacebacks in the biomechanics of the leveling phase using the MBT technique

Ricardo Cesar Moresca 09 June 2006 (has links)
O objetivo deste trabalho foi estudar os efeitos dos lacebacks ativos e passivos na biomecânica da fase de nivelamento, utilizando-se a técnica MBT. A amostra foi constituída de 29 sujeitos de pesquisa (22 do gênero feminino e 7 do gênero masculino), brasileiros, leucodermas e pardos, portadores de má oclusão de Classe I e com idade média de 15 anos e 5 meses. O tratamento ortodôntico foi planejado com as extrações dos primeiros pré-molares e, durante a fase estudada, foram empregados apenas fios de aço inoxidável (0.014”, 0.016”, 0.018”, 0.020” e 0.019” x 0.025”). Os recursos de ancoragem utilizados para os arcos dentários superior e inferior foram, respectivamente, o aparelho extrabucal tipo IHG e o arco lingual fixo. De acordo com a indicação dos lacebacks, a amostra foi dividida em quatro grupos: grupo I – 14 sujeitos que utilizaram lacebacks ativos no arco dentário superior; grupo II – 9 sujeitos que utilizaram lacebacks passivos no arco dentário superior; grupo III – 19 sujeitos que utilizaram lacebacks ativos no arco dentário inferior e grupo IV – 10 sujeitos que utilizaram lacebacks passivos no arco dentário inferior. Para cada indivíduo da amostra foram tomadas duas telerradiografias laterais, uma ao início e outra ao término da fase de nivelamento, com um intervalo médio de 21 meses. Os dados foram coletados utilizando-se o método cefalométrico computadorizado. Para a análise de erros, o método cefalométrico foi repetido em todos os sujeitos da amostra, pelo mesmo operador, com um intervalo mínimo de 15 dias entre as medidas. Os resultados indicaram que as variações observadas foram compatíveis com as estimativas de erros operacionais em estudos cefalométricos. Após a análise estatística e a interpretação dos resultados, verificou-se que, no grupo I, apenas a coroa do primeiro molar superior sofreu um movimento mesial e que tanto a coroa como a raiz do incisivo central superior apresentaram um movimento em direção lingual. No entanto, as inclinações destes dentes não foram alteradas. No grupo II, o primeiro molar superior se manteve estável e somente a coroa do incisivo central superior se movimentou em direção lingual, produzindo uma rotação horária deste dente. No grupo III, observou-se uma mesialização, tanto da coroa como da raiz, e extrusão do primeiro molar inferior, enquanto a posição do incisivo central inferior permaneceu inalterada. As inclinações destes dentes também não foram alteradas. No grupo IV, verificou-se que nem o primeiro molar inferior nem o incisivo central inferior apresentaram variações no sentido ântero-posterior. Verticalmente, houve extrusão apenas do primeiro molar inferior. / The purpose of this study was to evaluate the effects of active and passive lacebacks in the biomechanics of the leveling phase, using the MBT technique. The sample was composed of 29 Brazilian subjects (22 female and 7 male), Caucasian, with Class I malocclusion and mean age of 15 years and 5 months. The orthodontic treatment was planned with the extraction of the first premolars, and the leveling phase was performed with stainless steel wire only (0.014”, 0.016”, 0.018”, 0.020” e 0.019” x 0.025”). The anchorage control devices used in the upper and lower arches were, respectively, the IHG extraoral appliance and the fixed lingual arch. According to the type of laceback prescription, the sample was divided into four groups: group I – 14 subjects in which active lacebacks were used in the upper arch; group II – 9 subjects in which passive lacebacks were used in the upper arch; group III – 19 subjects in which active lacebacks were used in the lower arch; group IV – 10 subjects in which passive lacebacks were used in the lower arch. For each subject of the sample two lateral cephalometric radiographs were taken: one at the beginning and another at the end of the leveling phase, with a mean interval of 21 months. The data were collected using the resources of computerized cephalometry. To perform the analysis of errors, the cephalometric method was repeated in all subjects of the sample, by the same operator, with a minimum interval of 15 days between the measurements. The results revealed that the observed variations were compatible with the estimates of operational errors in cephalometric studies. After statistical analysis and interpretation of the results, it was observed that in group I, only the crown of the upper first molar presented a mesial movement. As to the upper central incisor, both the crown and the root presented a lingual movement. However, the inclination of these teeth was not affected. In group II, the upper first molar remained stable and only the crown of the upper central incisor moved lingually, leading to a clockwise rotation of this tooth. In group III, a mesial movement of both the crown and the root of the lower first molar was observed, along with its extrusion, whereas the position of the lower central incisor remained unchanged. The inclination of these teeth was not affected either. In group IV, it was observed that neither the lower first molar nor the lower central incisor experienced variations in the anteroposterior sense. Vertically, there only was extrusion of the lower first molar.
238

Avaliação da contaminação microbiana de aparelhos ortodônticos removíveis, com e sem utilização de agente antimicrobiano, pela técnica Checkerboard DNA-DNA Hybridization - Estudo Clínico Randomizado / Detection of microbial contamination of removable orthodontic appliances with or without use of antimicrobial agent, by the Checkerboard DNA-DNA Hybridization, A randomized clinical study

Marcela Perdiza 14 October 2009 (has links)
O objetivo do presente estudo clínico randomizado foi avaliar in vivo, por meio da técnica de biologia molecular Checkerboard DNA-DNA Hybridization: 1) A contaminação de aparelhos ortodônticos removíveis por 40 espécies bacterianas; 2) A eficácia da utilização do gluconato de clorexidina a 0,12% (Periogard®) sobre microrganismos cariogênicos; e 3) A eficácia da utilização do gluconato de clorexidina a 0,12% (Periogard®) sobre microrganismos periodontopatogênicos dos complexos laranja e vermelho. Participaram do estudo 20 pacientes de 7 a 11 anos de idade, em tratamento com aparelhos ortodônticos removíveis. O estudo constou de 2 etapas, com intervalo de 15 dias entre cada uma, de forma que todos os pacientes participassem tanto do grupo controle, quanto do grupo experimental. Em cada etapa os pacientes receberam um novo aparelho (totalizando 2 aparelhos por indivíduo) e um frasco plástico contendo a solução a ser borrifada sobre os aparelhos, porém os indivíduos não sabiam qual solução estavam utilizando. Os aparelhos foram utilizados em período integral, inclusive à noite, sendo removidos apenas durante as refeições Os pacientes do Grupo Controle foram orientados a usar solução placebo, sob a forma de spray, 2 vezes por semana, por 7 dias. Os pacientes do Grupo Experimental foram orientados a usar solução à base de gluconato de clorexidina a 0,12% (Periogard®) sob a forma de spray, da mesma forma que o grupo Controle. Decorridos 7 dias, os aparelhos de cada etapa foram removidos e processados para detecção de 40 espécies bacterianas, incluindo microrganismos cariogênicos e periodontopatogênicos, pela técnica Checkerboard DNA-DNA Hybridization. Os resultados obtidos foram analisados por meio do teste não-paramétrico de Wilcoxon, utilizando o software SAS (Statistical Analysis System). O nível de significância adotado foi de 5%. De acordo com os resultados obtidos observou-se que os aparelhos ortodônticos removíveis dos pacientes do grupo controle estavam densamente contaminados pelos microrganismos avaliados. A maioria das sondas utilizadas estava presente nas amostras desse grupo, sendo que S. sanguinis, S. oralis, S. gordonii e E. corrodens ocorreram em 100% dos aparelhos. Dentre os microrganismos cariogênicos, S. mutans e S. sobrinus foram encontrados em maiores quantidades que L. acidophilus e L. casei. As bactérias periodontopatogênicas pertencentes ao complexo vermelho foram evidenciadas em maiores quantidades que as pertencentes ao complexo laranja. Dentre os demais complexos não associados com patologias específicas, o complexo roxo apresentou-se em maiores quantidades, estando presente em 34% das amostras. Após o uso de spray com gluconato de clorexidina a 0,12%, observou-se uma diminuição significante dos microrganismos cariogênicos (S.mutans e S. sobrinus e L. acidophilus) nos aparelhos ortodônticos removíveis (p<0,05). Observou-se também uma diminuição significante de todos os microrganismos periodontopatogênicos dos complexos laranja e vermelho (p<0,05), em relação ao grupo controle, com exceção apenas do T. socranskii. Conclui-se que os aparelhos ortodônticos removíveis encontraram-se multicolonizados por diversas espécies bacterianas e que a clorexidina, utilizada duas vezes por semana sob a forma de spray, foi eficaz na redução dos níveis de microrganismos cariogênicos e periodontopatogênicos dos complexos laranja e vermelho, nesses aparelhos. / Using the Checkerboard DNA-DNA Hybridization biomolecular technique, this randomized clinical study evaluated: 1) the contamination of removable orthodontic appliances by 40 bacterial species; 2) the efficacy of 0.12% chlorhexidine gluconate (Periogard®) spray against cariogenic microorganisms;and 3) the efficacy of 0.12% chlorhexidine gluconate spray against periodontopathogenic microorganisms of the orange and red complexes. Twenty 7-11-year-old patients under treatment with removable orthodontic appliances were enrolled. The study had two phases, with a 15-day interval between them, in such a way that patients participated both in the control and in the experimental group. In each phase, the patients received a new appliance (total of 2 appliances per patient) and a bottle containing a solution to be sprayed onto the appliances, but they were blinded to whether it was a placebo solution or an antimicrobial agent. The patients were instructed to wear the appliances full-time, even at night, removing only at meals. The patients in the control and experimental groups were instructed to spray the placebo or the 0.12% chlorhexidine gluconate-based solution (Periogard®), respectively, onto the appliances twice a week during 7 days. After this period, the appliances of each phase were collected and processed for detection of 40 bacterial species, including cariogenic and periodontopathogenic microorganisms by the Checkerboard DNA-DNA Hybridization technique. Data were analyzed statistically by the non-parametric Wilcoxon test using the SAS software (Statistical Analysis System) at 5% significance level. The results showed that the removable orthodontic appliances of the patients in the control group were heavily contaminated by the target microorganisms. Most bacterial probes used were present in the control samples, S. sanguinis, S. oralis, S. gordonii and E. corrodens being detected in 100% of the appliances. Among the cariogenic microorganisms, S. mutans and S. sobrinus were found in larger numbers than L. acidophilus and L. casei. The number of red complex periodontopathogenic bacteria was larger than that of orange complex periodontopathogenic bacteria. Among the other bacterial complexes not associated with specific pathologies, purple complex bactéria were present in larger numbers, being detected in 34% of the samples. After use of the 0.12% chlorhexidine gluconate spray, the number of the cariogenic microorganisms (S.mutans, S. sobrinus and L. acidophilus) decreased significantly in the removable orthodontic appliances (p<0,05). There was also a significant decrease in the numbers of all periodontopathogenic microorganisms of the orange and red complexes (p<0,05), compared to the control group, except for T. socranskii. In conclusion, the removable orthodontic appliances were multicolonized by several bacterial species, and the use of chlorhexidine spray twice a week was effective in reducing the levels of cariogenic and periodontopathogenic microorganisms of the orange and red complexes.
239

Utilização da tecnologia CAD/CAM no planejamento e tratamento ortodôntico de pacientes com má-oclusão de Classe I /

Moreira, Fernando César. January 2020 (has links)
Orientador: Luis Geraldo Vaz / Resumo: Os sistemas CAD/CAM têm auxiliado ortodontistas no planejamento e posicionamento de braquetes com o objetivo de minimizar os erros e melhorar a qualidade do tratamento. Este estudo teve como objetivo validar as mensurações realizadas no software do sistema eXceed™, avaliar a previsibilidade e as alterações dento-alveolares. A amostra foi composta por 24 adultos jovens, portadores de má-oclusão Classe I de Angle. Foram obtidas Tomografia Computadorizada de Feixe Cônico (TCFC) antes e após o tratamento para avaliar as alterações dento-alveolares. Modelos de gesso foram obtidos por moldagens das arcadas com alginato e posteriormente digitalizados por meio de um escâner de mesa 3Shape R700 (3Shape Dental System™, Copenhague, Dinamarca). Os modelos 3D foram convertidos em estereolitografia (.stl) pelo OrthoAnalyser™ e exportados para a plataforma eXceed™ para o planejamento e criação do setup virtual. Dispositivos de colagem indireta foram fabricados a partir dos modelos 3D com as informações da posição idealizada dos braquetes sobre o modelo virtual. Os pacientes foram submetidos ao tratamento ortodôntico com aparelho fixo e braquetes autoligados. Os modelos 3D dos setups digitais iniciais foram comparados com os modelos digitais dos casos tratados (após o completo alinhamento e nivelamento das arcadas com o fio de aço .019”x.025”). As mensurações lineares realizadas em ambos os grupos pelo software Geomagic® foram avaliadas empregando-se o sistema de classificação do American Bo... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
240

Understanding mechanical environment changes and biological responses to canine retraction using t-loop

Jiang, Feifei 05 1900 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Predictability of tooth displacement in response to specific orthodontic load system directly links to the quality and effectiveness of the treatment. The key questions are how the tooth’s environment changes in response to the orthodontic load and how the biological tissues respond clinically. The objectives of this study are to determine the mechanical environment (ME) changes and to quantify the biological tissues’ response. Eighteen (18) patients who needed maxillary bilateral canine retractions were involved in the study. A method was developed to quantify the 3D load systems on the canine, which allowed the treatment strategies to be customized in terms of orthodontic loading systems to meet either translation (TR) or controlled tipping (CT) requirement. Dental casts were made before and after each treatment interval, and the Cone Beam Computed Tomography (CBCT) scans were taken prior to and following the entire treatment for control of treatment strategy and post treatment evaluations. Finite element method (FEM) was applied to calculate the location of center of resistance (CRes) for tooth movement control. The location and variation of CRes were recorded and compared with previous studies. A quick CRes assessment method that locates CRes by calculating the centroid of the contact surface (CCS) and the centroid of the projection of root surface (CPCS) in certain direction was also tested and compared with the results from FEM. Customized T-loop spring, a kind of orthodontic appliance, was designed, fabricated, and calibrated on a load measuring system to ensure that the load met the clinician’s prescription. The treatment outcomes in terms of tooth displacement and root resorption characterized by the changes of tooth length and volume as well as the bone mineral density (BMD) represented by the Hounsfield units (HU) change were recorded and analyzed. The ME in terms of stress were also calculated by using FEM. Paired t-test and mixed model ANOVA methods were used to analyze the relationships between the mechanical inputs (quantified and customized load, and corresponding stress) and clinical outcomes (root resorption and BMD change). It was found that the overall root resorption is not significant for canine retraction, but apical root resorption does occur, meaning that orthodontic load is not a sufficient factor. Also, it was observed that HU distribution changed significantly in both root and alveolar bone. The maximum reduction was on the coronal level in the direction perpendicular to the direction of movement in root, and in the direction of the tooth movement at the coronal level in bone. In addition, it was determined that the locations of the CRes in the MD and BL directions were significantly different. The locations of the CRes of a human canine in MD and BL directions can be estimated by finding the CPCSs in the two directions. Finally, it was shown that the stress invariants can be used to characterize how the osteocytes feel when ME changes. The stress invariants in the alveolar bone are not significantly affected by different M/F. The higher bone modeling/remodeling activities along the direction of tooth movement may be related to the initial volumetric increase and decrease in the alveolar bone.

Page generated in 0.0691 seconds