• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 70
  • Tagged with
  • 70
  • 70
  • 52
  • 51
  • 50
  • 46
  • 37
  • 15
  • 10
  • 10
  • 9
  • 9
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Avalia??o da viabilidade, ades?o e prolifera??o de c?lulas tronco da medula ?ssea e fibroblastos NIH3T3 cultivadas em matriz de PLGA com rhGH

Gerzson, Alexandre da SIlveira 23 March 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-05-17T20:18:03Z No. of bitstreams: 1 TES_ALEXANDRE_DA_SILVEIRA_GERZSON_COMPLETO.pdf: 8833517 bytes, checksum: b4672493ffabfc3e5c284282aa067e14 (MD5) / Made available in DSpace on 2016-05-17T20:18:03Z (GMT). No. of bitstreams: 1 TES_ALEXANDRE_DA_SILVEIRA_GERZSON_COMPLETO.pdf: 8833517 bytes, checksum: b4672493ffabfc3e5c284282aa067e14 (MD5) Previous issue date: 2016-03-23 / Biomaterials, as an alternative to autogenous bone and other biological tissues, have been widely used in oral and maxillofacial surgery. In this context, a biomaterial that functions as a scaffold (osteoconductor), combined with a growth factor (osteoinductor), would be of great interest for clinical application. Biodegradable polymers used for slow drug release have been investigated, demonstrating good results and interesting potential. Growth hormone (rhGH) may be released by incorporating it into these polymers. This study aimed to evaluate cell adhesion and proliferation of a polymeric biomaterial for slow release of rhGH. PLGA and PLGA/PCL (at a 70/30 ratio of PLGA to PCL) matrices were prepared by the solvent evaporation method, combined or not with GH. The biomaterials were tested for toxicity and cell viability using an MTT assay with NIH3T3 mouse cells (ATCC). Cell toxicity was assessed at 24, 48, 72 hours, and 7 days of biomaterial exposure to culture medium. After were tested?for cell adhesion and proliferation by culture in mesenchymal stem cells derived from Wistar rat bone marrow, DAPI staining, and subsequent cell counting, in addition to scanning electron microscopy. Cell adhesion and proliferation was assessed at 24 and 72 hours of biomaterial exposure to culture medium. All polymers had high cell viability rates. However, from 48 hours onwards, the groups with rhGH-polymer combinations had better results than the polymer groups without association with GH when compared to the control group. At 7 days of culture, only the pure PLGA matrix showed a significant difference from the control group. These results may suggest a preference of cells for the presence of rhGH in the biomaterial in culture medium? especially in the PLGA matrix. GH appeared to contribute to the increase in cell viability observed at some assessment time points, especially when combined with PLGA as compared to pure PLGA. All tested polymers exhibited cell adhesion and proliferation. However, PLGA-based biomaterials, especially when combined with rhGH, showed greater cell proliferation when the difference in growth from 24 to 72 hours was evaluated. rhGH appeared to modify the polymer surface, with increased roughness and microporosity. This feature was more evident in the PLGA+rhGH combination. Further studies are required to clarify this potential for development of new biomaterials. / Biomateriais como alternativas ao osso aut?geno e outros tecidos biol?gicos, s?o muito utilizados no tratamento de pacientes na rotina cir?rgica da regi?o maxilofacial. Neste contexto, um biomaterial com caracter?sticas de arcabou?o (osteocondutor), e associado ? um fator de crescimento (osteoindutor), seria de grande interesse para pesquisa e aplica??o cl?nica. Pol?meros biodegrad?veis, utilizados para a libera??o lenta de medicamentos, vem sendo estudados, demonstrando bons resultados e interessante potencial. o rhGH pode ser liberado atrav?s da sua incorpora??o ? estes pol?meros. Desta forma, se faz necess?rio a avalia??o da biocompatibilidade e toxicidade de um biomaterial polim?rico para libera??o lenta do medicamento. Atrav?s da t?cnica de evapora??o de solvente foram preparados matrizes de PLGA e PLGA/PCL na raz?o 70/30 de PLGA e PCL, respectivamente, associados ou n?o ao rhGH. Os biomateriais foram testados relacionados ? sua toxicidade e viabilidade celular, atrav?s de um ensaio de MTT com c?lulas de camundongo NIH 3T3 ATCC. A avalia??o da toxicidade celular foi realizada nos tempos de 24 horas, 48 horas, 72 horas e 7 dias de exposi??o dos biomateriais com o meio de cultura. Ap?s, os biomateriais foram testados relacionados ? sua ades?o e prolifera??o celular, atrav?s do cultivo em c?lulas-tronco mesenquimais de rato Wistar, com ensaio de colora??o DAPI e posterior contagem celular, al?m de microscopia eletr?nica de varredura. A avalia??o da ades?o e prolifera??o celular foi realizada nos tempos de 24 e 72 horas de exposi??o dos biomateriais com o meio de cultura. Todos os pol?meros testados apresentaram altas taxas de viabilidade celular, por?m, os grupos associados ao rhGH parecem demonstrar melhores resultados do que os grupos de pol?meros sem associa??o ao horm?nio quando comparados ao grupo controle em alguns per?odos do experimento. O que pode sugerir uma prefer?ncias das c?lulas ? presen?a do rhGH no biomaterial presente no meio de cultura, principalmente na matriz de PLGA. Os pol?meros testados, apresentaram ades?o e prolifera??o celular, por?m, os biomateriais ? base de PLGA, principalmente associados ao rhGH pareceram demonstrar maior prolifera??o celular quando avaliada a diferen?a do crescimento de 24 para 72horas. O GH modificou a superf?cie do pol?mero, aumentando a rugosidade e microporosidade. Aspecto visualizado principalmente quando incorporado ao PLGA. Mais estudos s?o necess?rios para verificar alternativas de novos biomateriais para libera??o lenta de f?rmacos.
42

Emuls?o alqu?dica : estudo do processo de invers?o e do uso de um emulsionante biodegrad?vel sobre as propriedades f?sico-qu?micas / Alkyd emulsion : study of the inversion process and the use of a biodegradable emulsifier on the physicochemical properties

Pilz, Cl?udia Ferrari 08 March 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-05-25T12:57:31Z No. of bitstreams: 1 TES_CLAUDIA_FERRARI_PILZ_COMPLETO.pdf: 6306033 bytes, checksum: 623cbd1dc3cf75238fdcfab9f65673b0 (MD5) / Made available in DSpace on 2016-05-25T12:57:31Z (GMT). No. of bitstreams: 1 TES_CLAUDIA_FERRARI_PILZ_COMPLETO.pdf: 6306033 bytes, checksum: 623cbd1dc3cf75238fdcfab9f65673b0 (MD5) Previous issue date: 2016-03-08 / A tend?ncia atual na ?rea de revestimentos ? a utiliza??o de materiais que contribuam para a redu??o do conte?do org?nico vol?til dos produtos. Uma ?rea em desenvolvimento ? a que busca a prepara??o de emuls?es alqu?dicas que ofere?am as propriedades necess?rias e com custos atrativos para substituir as resinas alqu?dicas a base de solvente empregadas atualmente. Este trabalho estudou a rela??o de vari?veis de composi??o e de processo que possam produzir emuls?es est?veis empregando o processo de emulsionamento por invers?o de fase. Este processo ? largamente empregado no preparo de emuls?es em diversas ?reas, sendo tamb?m o m?todo adequado para emuls?es polim?ricas utilizadas em revestimentos e adesivos. O emulsionante ? um dos elementos chave do emulsionamento. No entanto, ? conhecido tamb?m que vari?veis de processo e relacionadas ao pol?mero possuem grande influ?ncia. Normalmente no estudo das vari?veis os experimentos s?o conduzidos de modo a avaliar os resultados isoladamente. Este trabalho utilizou um delineamento de experimentos fatorial para a an?lise do teor de emulsionante, propor??o de emulsionante i?nico e n?o i?nico (de origem sint?tica) e velocidade de adi??o de ?gua. Os resultados mostram que o teor de emulsionante ? o fator de maior influ?ncia sobre o tamanho de part?cula, estabilidade e volume de invers?o. Adicionalmente, a rela??o existente entre o teor total e a propor??o tamb?m ? de relev?ncia significativa. A avalia??o do uso de um emulsionante biodegrad?vel a base de polissacar?deo em substitui??o aos emulsionantes convencionais demonstrou que a invers?o apenas ocorreu quando o polissacar?deo foi incorporado na forma l?quida ao pol?mero e em combina??o com o emulsionante n?o i?nico sint?tico, havendo um desempenho inferior ao sistema tradicional em rela??o ?s mesmas propriedades. / A tend?ncia atual na ?rea de revestimentos ? a utiliza??o de materiais que contribuam para a redu??o do conte?do org?nico vol?til dos produtos. Uma ?rea em desenvolvimento ? a que busca a prepara??o de emuls?es alqu?dicas que ofere?am as propriedades necess?rias e com custos atrativos para substituir as resinas alqu?dicas a base de solvente empregadas atualmente. Este trabalho estudou a rela??o de vari?veis de composi??o e de processo que possam produzir emuls?es est?veis empregando o processo de emulsionamento por invers?o de fase. Este processo ? largamente empregado no preparo de emuls?es em diversas ?reas, sendo tamb?m o m?todo adequado para emuls?es polim?ricas utilizadas em revestimentos e adesivos. O emulsionante ? um dos elementos chave do emulsionamento. No entanto, ? conhecido tamb?m que vari?veis de processo e relacionadas ao pol?mero possuem grande influ?ncia. Normalmente no estudo das vari?veis os experimentos s?o conduzidos de modo a avaliar os resultados isoladamente. Este trabalho utilizou um delineamento de experimentos fatorial para a an?lise do teor de emulsionante, propor??o de emulsionante i?nico e n?o i?nico (de origem sint?tica) e velocidade de adi??o de ?gua. Os resultados mostram que o teor de emulsionante ? o fator de maior influ?ncia sobre o tamanho de part?cula, estabilidade e volume de invers?o. Adicionalmente, a rela??o existente entre o teor total e a propor??o tamb?m ? de relev?ncia significativa. A avalia??o do uso de um emulsionante biodegrad?vel a base de polissacar?deo em substitui??o aos emulsionantes convencionais demonstrou que a invers?o apenas ocorreu quando o polissacar?deo foi incorporado na forma l?quida ao pol?mero e em combina??o com o emulsionante n?o i?nico sint?tico, havendo um desempenho inferior ao sistema tradicional em rela??o ?s mesmas propriedades.
43

Caracteriza??o de atapulgita visando aplica??o para refor?o de materiais polom?ricos

Costa, Antonio Carlos Silva da 14 March 2011 (has links)
Made available in DSpace on 2014-12-17T14:07:00Z (GMT). No. of bitstreams: 1 AntonioCSC_DISSERT.pdf: 3611638 bytes, checksum: 66d2009e96e503fa1be4ca56924e34a1 (MD5) Previous issue date: 2011-03-14 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / The clay mineral attapulgite is a group of hormitas, which has its structures formed by microchannels, which give superior technological properties classified the industrial clays, clays of this group has a very versatile range of applications, ranging from the drilling fluid for wells oil has applications in the pharmaceutical industry. Such properties can be improved by activating acid and / or thermal activation. The attapulgite when activated can improve by up to 5-8 times some of its properties. The clay was characterized by X-ray diffraction, fluorescence, thermogravimetric analysis, differential thermal analysis, scanning electron microscopy and transmission electron microscopy before and after chemical activation. It can be seen through the results the efficiency of chemical treatment, which modified the clay without damaging its structure, as well as production of polymer matrix composites with particles dispersed atapugita / A atapulgita ? um argilomineral do grupo das hormitas, que tem suas estruturas formadas por microcanais, que lhe conferem propriedades tecnol?gicas superiores a argilas classificadas industriais, esse grupo de argilas tem um leque de aplica??es muito vers?til, que vai de fluido de perfura??o para po?os de petr?leo at? aplica??es na ind?stria farmac?utica. Tais propriedades podem ser melhoradas por ativa??o acida e/ou ativa??o t?rmica. A atapulgita quando ativada pode melhorar em at? de 5 a 8 vezes algumas de suas propriedades. A argila foi caracterizada por difra??o de raios X, fluoresc?ncia, an?lise termogravim?trica, an?lise t?rmica diferencial, microscopia eletr?nica de varredura e microscopia eletr?nica de transmiss?o antes e depois da ativa??o qu?mica. ? poss?vel observar, atrav?s dos resultados a efici?ncia do tratamento qu?mico, que modificou a argila sem danificar sua estrutura, assim como produ??o de composito de matriz polim?rica com part?culas dispersas de atapugita
44

Desenvolvimento e aplica??o do material comp?sito HRP/PANI/PEG-MWCNT como plataforma para detec??o de per?xido de hidrog?nio a baixo potencial / Development and application of HRP/PANI/PEG-MWCNT composite material as a platform for hydrogen peroxide detection with high sensitivity at low potential

Silva, Jussara Vieira da 26 February 2013 (has links)
Submitted by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2015-02-19T13:34:44Z No. of bitstreams: 5 jus.pdf: 3394180 bytes, checksum: 71d0ff7761a41fcaa36b37cfba79f687 (MD5) license_url: 52 bytes, checksum: 3d480ae6c91e310daba2020f8787d6f9 (MD5) license_text: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) license.txt: 2110 bytes, checksum: b4c884761e4c6c296ab2179d378436d4 (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2015-02-20T10:26:30Z (GMT) No. of bitstreams: 5 jus.pdf: 3394180 bytes, checksum: 71d0ff7761a41fcaa36b37cfba79f687 (MD5) license_url: 52 bytes, checksum: 3d480ae6c91e310daba2020f8787d6f9 (MD5) license_text: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) license.txt: 2110 bytes, checksum: b4c884761e4c6c296ab2179d378436d4 (MD5) / Made available in DSpace on 2015-02-20T10:26:30Z (GMT). No. of bitstreams: 5 jus.pdf: 3394180 bytes, checksum: 71d0ff7761a41fcaa36b37cfba79f687 (MD5) license_url: 52 bytes, checksum: 3d480ae6c91e310daba2020f8787d6f9 (MD5) license_text: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) license.txt: 2110 bytes, checksum: b4c884761e4c6c296ab2179d378436d4 (MD5) Previous issue date: 2013-12-17 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (Capes) / Atualmente os nanotubos de carbono (NTC) representam um importante grupo de nanomateriais com atrativas propriedades qu?micas, eletr?nicas e mec?nicas. Estes materiais podem ser combinados a pol?meros, de maneira a moldar as propriedades f?sicas desses compostos (nanotubos-pol?mero), aumentando sua condutividade el?trica, estabilidade qu?mica e resist?ncia mec?nica. O presente trabalho apresenta o desenvolvimentoum material comp?sitonanoestruturado ? base de polianilina (PANI) e nanotubos de carbono de paredes m?ltiplas(MWCNT), para tal, os NTC foram funcionalizados com agrupamentos amina (PEG-NH2). A inser??o do grupamento amina junto aos NTC (PEG-MWCNT) foi confirmada atrav?s da caracteriza??o deste material utilizando as t?cnicas de Microscopia Eletr?nica de Varredura (MEV), Espectroscopia de infravermelho com transformada de fourrier(FT-IR) e Espectroscopia de Energia dispersiva de Raios-X. Foi produzido um eletrodo modificado atrav?s da polimeriza??o do mon?mero anilinaem presen?a dos NTC funcionalizados denominado PANI/PEG-MWCNT. Foram analisadas as propriedades do comp?sito PANI/PEG-MWCNT pelas t?cnicas de Voltametria c?clica e Espectroscopia de Imped?ncia Eletroqu?mica, atrav?s das quais foi verificado que a presen?a combinada dos NTC e da PANI favorece forma??o de um material comp?sito com propriedades sin?rgicas. Al?m disso, atrav?s da Microbalan?a Eletroqu?mica de Cristal de Quartzo pode-se constatarque a dopagem da PANI com PEG-MWCNT favorece o transporte de pr?tons significativamente. Atrav?s da t?cnica de microscopia eletroqu?mica de varredura foi poss?vel evidenciar que existem mais s?tios ativos na superf?cie do filme de PANI/PEG-MWCNT do que na superf?cie da PANI devido ? incorpora??o uniforme dos MWCNT. Finalmente, o eletrodo modificado com o material comp?sito foi utilizado como plataforma no desenvolvimento de um biossensor enzim?tico, pela imobiliza??o da enzima HRP (HRP/PANI/PEG-MWCNT). O biossensor HRP/PANI/PEG-MWCNT apresentou um ?timo suporte para aredu??o de per?xido de hidrog?nio a baixo potencial (-100 mV) vs Ag/AgCl, bem como alta sensibilidade (1.01) ?Acm-2 ?M?1e baixo limite de detec??o de 0,5 ?M L-1. / Disserta??o (Mestrado) ? Programa de P?s-Gradua??o em Qu?mica, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2013. / ABSTRACT Currently carbon nanotubes (NTC) represent an important group of nanomaterials with attractive properties (chemical, electronic and mechanical). These materials can be combined with polymers in order to shape their physical properties of these compounds (nanotube-polymer), increasing its electrical conductivity, chemical stability and mechanical strength. In fact, this study shows the production of a nanostructured composite material based on polyaniline (PANI) and carbon nanotubes multi-walled (MWCNT), for this, the NTC were functionalized with amine groups (PEG-NH2). The insertion of the amine grouping together to NTC (MWCNT-PEG) was confirmed by the characterization of this material using the techniques of Scanning Electron Microscopy (SEM) spectroscopy, Fourier transform infrared (FT-IR) spectroscopy and energy dispersive X-Ray. A modified electrode was produced through polymerization in the presence of PANI called NTC functionalized PANI/PEG-MWCNT. The properties of the composite PANI/MWCNT-PEG were examined by cyclic voltammetry and Electrochemical Impedance Spectroscopy, it was found that the combined presence of the NTC and polyaniline in the modified electrode provides a formation of a composite material with synergistic properties. Furthermore, through the technique of Electrochemical Microbalance Quartz Crystal can be seen that doping of PANI with PEG-MWCNT facilitates significantly the transport of protons. Finally, through the technique of scanning electrochemical microscopy was possible to show that there are more active sites on the surface of the film of PANI / MWCNT-PEG than on the surface of PANI due to the incorporation of MWCNT uniform. Lastly, the modified electrode composite material was used as a support for a biosensor for immobilization of the enzyme HRP (HRP/PANI/PEG-MWCNT). The biosensor HRP/PANI/MWCNT-PEG showed a great support for the reduction of hydrogen peroxide at a low potential (-100mv) vs Ag / AgCl as well as high sensitivity (1.01) ?A cm-2 mM-1 and low detection limit 0.5 ?m.
45

Caracteriza??o e avalia??o da resist?ncia ? ades?o de sistema adesivo dent?rio processado com nanopart?culas de hidroxiapatita / Characterization and evaluation of the bond strength of dental adhesive system processed with nanoparticles of hydroxyapatite

Dumont, Vitor C?sar 01 February 2013 (has links)
Submitted by Nivaldo Melo (nivaldo.melo@ufvjm.edu.br) on 2015-11-27T21:56:09Z No. of bitstreams: 2 vitor_cesar_dumont.pdf: 1875665 bytes, checksum: 2527884b6adbcdee7fa97e50d48033cb (MD5) license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2015-12-01T17:04:58Z (GMT) No. of bitstreams: 2 vitor_cesar_dumont.pdf: 1875665 bytes, checksum: 2527884b6adbcdee7fa97e50d48033cb (MD5) license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) / Made available in DSpace on 2015-12-01T17:04:58Z (GMT). No. of bitstreams: 2 vitor_cesar_dumont.pdf: 1875665 bytes, checksum: 2527884b6adbcdee7fa97e50d48033cb (MD5) license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Previous issue date: 2013 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / Funda??o de Amparo ? Pesquisa do estado de Minas Gerais (FAPEMIG) / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico (CNPq) / O presente estudo modificou um sistema adesivo polim?rico convencional (AC) com nanopart?culas de hidroxiapatita (HAP) como carga, caracterizou os comp?sitos desenvolvidos e avaliou sua efetividade adesiva ? estrutura dent?ria. Depois de bem limpos e esterilizados em autoclave, pr?-molares rec?m-extra?dos por indica??o ortod?ntica em grupos et?rios inferior a 21 anos, foram seccionados no sentido horizontal, obtendo-se o ter?o m?dio da coroa do dente. Este foi seccionado novamente, no seu sentido vertical, obtendo-se duas sec??es, que foram inclu?das em tubo de policloreto de vinila (2 cm de di?metro x 1,5 cm de altura) preenchidos com resina poli?ster. Em metade dos esp?cimes foram expostas superf?cies em esmalte e na outra metade superf?cies em dentina. Na primeira etapa, as sec??es foram divididas em oito grupos (n = 6), em esmalte (E): G1 ? AC; G2, G3 e G4 - AC modificado com 0,05, 0,10 e 0,15 g/ml de HAP, respectivamente; e em dentina (D): G5 ? AC; G6, G7 e G8 - AC com as mesmas concentra??es de HAP utilizadas em esmalte. Decorridos 14 dias em ?gua destilada a 37 ?C (? 1?C), as amostras foram submetidas ao teste de microcisalhamento em uma m?quina universal de ensaio. As ?reas de fratura dos esp?cimes foram analisadas por microscopia de Luz (ML) e amostras representativas de cada grupo foram caracterizadas por microscopia eletr?nica de varredura (MEV) e espectroscopia de energia dispersiva de raios-X (EDS). Apesar da m?dia dos valores de resist?ncia ? ades?o dos grupos AC modificados com HAP se apresentar mais alta, principalmente em esmalte, n?o houve signific?ncia estat?stica entre os grupos (ANOVA), (p>0,05). Maior quantidade de falhas adesivas foi observada na interface de uni?o. Na segunda etapa, as coroas dos dentes foram seccionadas como anteriormente e as sec??es foram divididas em 10 grupos (n = 15): G1E e G1D ? AC; G2E e G2D - AC-adesivo modificado com 0,10 g/ml de HAP; G3E e G3D - AC-primer modificado com 0,10 g/ml de HAP; G4E e G4D - sistema adesivo monocomponente; G5E e G5D - sistema adesivo autocondicionante. Ap?s 14 dias, os esp?cimes foram submetidos ao teste de microcisalhamento. As ?reas de fratura dos grupos foram analisadas por ML e amostras representativas foram caracterizadas por MEV/EDS. Os comp?sitos modificados e seus materiais precursores foram caracterizados atrav?s de difra??o de raios-X (XRD) e espectroscopia de infravermelho por transformada de Fourier (FTIR). Diferen?a estatisticamente significativa foi observada entre os grupos (Kruskal-Wallis), (p<0,01), em E e D. G3 apresentou os maiores valores de resist?ncia ? ades?o em esmalte (64,40MPa, ?7,36) e em dentina (39,59 MPa, ?21,46). A an?lise das interfaces sistema adesivo/estrutura dent?ria mostrou a presen?a de fraturas adesivas na maioria dos esp?cimes. Fraturas coesivas foram encontradas em G2E, G3E, G4E e G3D. Verificou-se que os comp?sitos desenvolvidos com a incorpora??o de nanopart?culas de HAP ? sua composi??o (G3E e G3D) mostraram melhoria significativa na resist?ncia de ades?o ? estrutura dent?ria. Os comp?sitos apresentaram-se est?veis, com fases cristalogr?ficas e amorfas, e mostraram morfologia e estrutura qu?mica similares aos seus materiais precursores. / Disserta??o (Mestrado) ? Programa de P?s-Gradua??o em Odontologia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2013. / ABSTRACT The present study modified a conventional polymer adhesive system (AC) with nanoparticles of hydroxyapatite (HAP) as filler, characterized the composites developed and evaluated its adhesive effectiveness to tooth structure. After completely cleaned and sterilized in an autoclave, premolars recently extracted under orthodontic indication in groups aged below 21 years, were sectioned horizontally, providing the middle third of the crown of the tooth. This one was sectioned again vertically, resulting in two sections which were embedded in polyvinyl chloride tube (2 cm diameter x 1.5 cm high) filled with polyester resin. In half of the specimens, enamel surfaces were exposed and in the other half, dentine surfaces. In the first stage, the sections were divided into eight groups (n = 6) in enamel (E): G1 ? AC; G2, G3 and G4 - AC modified with 0.05, 0.10 and 0.15 g / ml HAP, respectively; and in dentin (D): G5 ? AC; G6, G7 and G8 - AC with the same concentrations of HAP used in enamel. After 14 days in distilled water at 37 ? C (? 1 ? C), the specimens were submitted to a micro-shear test on a universal testing machine. The specimens? fractures were observed under light microscopy (LM) and representative samples of each group were characterized by scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). Although the average values of the bond strength of the groups AC modified with HAP presented to be higher, mainly in enamel, there was no statistical significance between the groups (ANOVA), (p > 0.05). Larger amount of adhesive failures were observed at the interface bond. In the second stage, the teeth were sectioned as previously and the sections were divided into 10 groups (n = 15): G1E and G1D ? AC; G2E and G2D ? AC ? adhesive modified with 0.10 g / ml HAp, G3E and G3D ? AC ? primer modified with 0.10 g / ml of HAp; G4E and G4D ? single-component adhesive system; G5E and G5D ? auto-conditioning adhesive system. After 14 days, the specimens were submitted to micro-shear testing. The areas of fracture in the groups were analyzed by LM and representative samples were characterized by SEM / EDS. The modified composites and their precursor materials were characterized by X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR). A statistically significant difference was observed between groups (Kruskal-Wallis), (p <0.01) in E and D. G3 presented the highest values of resistance to adhesion in enamel (64.40 MPa ? 7.36) and in dentin (39.59 MPa ? 21.46). The analysis of the interfaces adhesive system / tooth structure showed the presence of adhesive fractures in most specimens. Cohesive fractures were found in G2E, G3E, G4E and G3D. It was found that the composites developed with incorporation of nanoparticles of HAP to their composition (G3E and G3D) showed significant improvement in the bond strength to tooth structure. The composites were stable, with crystalline and amorphous phases, and showed morphology and chemical structure similar to their precursor materials.
46

Estudo da redu??o de arrasto induzido por pol?meros em escoamentos internos turbulentos em dutos

Queiroz, Luiz Paulo de Oliveira 16 February 2016 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2016-07-08T21:06:57Z No. of bitstreams: 1 LuizPauloDeOliveiraQueiroz_DISSERT.pdf: 2136426 bytes, checksum: 522731129ac7437c10bd9e82c9e5ca65 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2016-07-12T20:37:04Z (GMT) No. of bitstreams: 1 LuizPauloDeOliveiraQueiroz_DISSERT.pdf: 2136426 bytes, checksum: 522731129ac7437c10bd9e82c9e5ca65 (MD5) / Made available in DSpace on 2016-07-12T20:37:04Z (GMT). No. of bitstreams: 1 LuizPauloDeOliveiraQueiroz_DISSERT.pdf: 2136426 bytes, checksum: 522731129ac7437c10bd9e82c9e5ca65 (MD5) Previous issue date: 2016-02-16 / Escoamentos turbulentos e laminares s?o encontrados, frequentemente, em diversas aplica??es de engenharia, como em compressores e bombas e ao redor de carros, avi?es e navios. O atrito superficial, grande respons?vel pelas perdas energ?ticas, ? consideravelmente maiores no tipo de escoamento turbulento do que em escoamentos laminares. Seu estudo ? bastante desafiador, devido a sua natureza complexa. A principal justificativa para este estudo baseia-se na otimiza??o dos recursos energ?ticos, por motivos econ?micos principalmente, atrav?s do estudo da redu??o de arrasto induzido por pol?meros. Neste trabalho, ? estudada a redu??o de arrasto por indu??o de pol?meros a partir da utiliza??o de uma bancada experimental situada no laborat?rio de mec?nica dos fluidos da UFRN. A bancada experimental foi constru?da e calibrada exclusivamente para este trabalho. Foram utilizados como aditivos polim?ricos o Polietileno glicol 4000, o Polyox WSR N60K, Polyox WSR 301 e o Polyox WSR 205. A redu??o de arrasto induzida por pol?meros ? investigada a partir da an?lise de um escoamento, tal an?lise parte do princ?pio da medi??o de press?o em dois pontos do escoamento e culmina no c?lculo da perda de carga e do fator de atrito, o que possibilita analisar a influ?ncia da adi??o de pol?meros na redu??o do arrasto em escoamentos sejam eles laminares ou turbulentos. N?o foi observado redu??o de arrasto no polietileno glicol 4000 na concentra??o analisada. O Polyox WSR N60K, o Polyox WSR 301 e o Polyox WSR 205 apresentaram redu??o de arrasto com destaque para o Polyox WSR 301 que apresentou maior redu??o dentre dos pol?meros estudados, o que conclui-se que o Polyox WSR 301 ? mais eficiente para promover a redu??o de arrasto em tubos r?gidos. / The flows turbulent and laminar are present in various applications of engineering and one of the villain of energy loss big is the surface friction. Currently, there are several research aimed for the study of reducing drag (DR) with the objective of developing effective methods to reduce the friction. Regardless of numerous research carried out until today, the phenomenon DR still remains in study not it is fully understood. This paper studied the drag reduction by polymer induction in turbulent internal flows in ducts. We constructed a testing bench to perform the analysis of drag reduction, the bench has basically two manometers with a 8.5 psi full scale, a peripheral pump 0.5 HP, an acrylic tank, valves and tubes pvc and is situated in the Laboratory Fluid Mechanics UFRN. Were used as polymer additives to polyethylene glycol 4000, the Polyox WSR N60K, Polyox WSR 301 and Polyox WSR 205. The rationale for the choice of these polymers is their wide application in situations requiring greater energy efficiency, such as the addition reducing polymers for the jet used by the fire department to achieve greater distances. The induced drag reduction polymers is investigated from the turbulent flow analysis, with Reynolds number in a range between 2?104 ? 5?104. The part of the first pressure measurement analysis on two points of the turbulent flow, then the density measurements, viscosity of the polymer solutions and culminates in drag reduction calculation, allowing to analyze the influence of the addition polymer in reducing the drag in turbulent flows. The Polyox WSR N60K, the Polyox WSR 301 and Polyox WSR 205 decreased drag highlighting the Polyox WSR 301 that showed the greatest reduction among the polymers studied, which concluded that the Polyox WSR 301 is more efficient to drag reduction in pipes. There was no drag reduction in polyethylene glycol 4000 to the measured concentration.
47

Uma nova proposta de fluidos de perfura??o aquosos ? base de pol?meros vin?licos e bentonita para po?os de alta temperatura e press?o

C?mara, Paulo C?sar Fran?a da 13 January 2016 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2016-07-22T15:10:02Z No. of bitstreams: 1 PauloCesarFrancaDaCamara_DISSERT.pdf: 1632237 bytes, checksum: 8e0cfc36c6d0195008822612bbadae28 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2016-07-27T19:54:25Z (GMT) No. of bitstreams: 1 PauloCesarFrancaDaCamara_DISSERT.pdf: 1632237 bytes, checksum: 8e0cfc36c6d0195008822612bbadae28 (MD5) / Made available in DSpace on 2016-07-27T19:54:25Z (GMT). No. of bitstreams: 1 PauloCesarFrancaDaCamara_DISSERT.pdf: 1632237 bytes, checksum: 8e0cfc36c6d0195008822612bbadae28 (MD5) Previous issue date: 2016-01-13 / O avan?o das perfura??es em po?os mais profundos tem requerido materiais cada vez mais termoest?veis que v?o ao encontro ?s condi??es de po?o. A utiliza??o de fluidos sint?ticos, que costumam apresentar uma boa estabilidade qu?mica, esbarra nas limita??es ambientais, al?m de gerarem mais descarte e requererem um tratamento oneroso dos cascalhos perfurados, que s?o por vezes n?o eficientes e exigem componentes mec?nicos que dificultam a opera??o. A ado??o de fluidos aquosos, geralmente, implica na utiliza??o do lignossulfonato de cromo, empregado como dispersante, que confere estabilidade nas propriedades reol?gicas e controle de filtrado de fluidos submetidos a altas temperaturas e press?es. Por?m, devido ao impacto ambiental associado ? utiliza??o de compostos cromados, o setor de perfura??o necessita de alternativas que mantenham ?ntegras as propriedades e garantam sucesso da opera??o tendo em vista a forte influencia da temperatura sob a viscosidade de fluidos aquosos e nos pol?meros empregados nesse tipo de fluido, frequentemente de origem natural, passivos de hidr?lise e degrada??o biol?gica. Pol?meros vin?licos, por possu?rem cadeia predominantemente carb?nica, resistem a maiores temperaturas. Al?m disso, a aus?ncia de liga??es acetal diminui a sensibilidade a ataques por bact?rias. Medidas reol?gicas dos fluidos de perfura??o utilizando polivinilpirrolidona (PVP), poliacrilamidas parcialmente hidrolisada e argila, como principais constituintes, foram determinadas atrav?s do viscos?metro rotativo da Fann, modelo 35A, e o volume de filtrado obtido atrav?s de filtra??o ATAP, seguindo a norma API 13B-2. Observou-se que o novo sistema de fluido em que o PVP de alta massa molar foi utilizado apresentou maiores valores de viscosidade, g?is e limite de escoamento, por efeito da flocula??o argilosa. Por sua vez, o PVP de baixa massa molar contribuiu para a forma??o de sistemas dispersos com menores valores nas propriedades reol?gicas e de filtrado. Ambos os sistemas apresentaram ganho de estabilidade t?rmica, mantendo os par?metros reol?gicos est?veis. Os resultados foram ainda corroborados atrav?s de ensaios de inchamento linear de argila.O avan?o das perfura??es em po?os mais profundos tem requerido materiais cada vez mais termoest?veis que v?o ao encontro ?s condi??es de po?o. A utiliza??o de fluidos sint?ticos, que costumam apresentar uma boa estabilidade qu?mica, esbarra nas limita??es ambientais, al?m de gerarem mais descarte e requererem um tratamento oneroso dos cascalhos perfurados, que s?o por vezes n?o eficientes e exigem componentes mec?nicos que dificultam a opera??o. A ado??o de fluidos aquosos, geralmente, implica na utiliza??o do lignossulfonato de cromo, empregado como dispersante, que confere estabilidade nas propriedades reol?gicas e controle de filtrado de fluidos submetidos a altas temperaturas e press?es. Por?m, devido ao impacto ambiental associado ? utiliza??o de compostos cromados, o setor de perfura??o necessita de alternativas que mantenham ?ntegras as propriedades e garantam sucesso da opera??o tendo em vista a forte influencia da temperatura sob a viscosidade de fluidos aquosos e nos pol?meros empregados nesse tipo de fluido, frequentemente de origem natural, passivos de hidr?lise e degrada??o biol?gica. Pol?meros vin?licos, por possu?rem cadeia predominantemente carb?nica, resistem a maiores temperaturas. Al?m disso, a aus?ncia de liga??es acetal diminui a sensibilidade a ataques por bact?rias. Medidas reol?gicas dos fluidos de perfura??o utilizando polivinilpirrolidona (PVP), poliacrilamidas parcialmente hidrolisada e argila, como principais constituintes, foram determinadas atrav?s do viscos?metro rotativo da Fann, modelo 35A, e o volume de filtrado obtido atrav?s de filtra??o ATAP, seguindo a norma API 13B-2. Observou-se que o novo sistema de fluido em que o PVP de alta massa molar foi utilizado apresentou maiores valores de viscosidade, g?is e limite de escoamento, por efeito da flocula??o argilosa. Por sua vez, o PVP de baixa massa molar contribuiu para a forma??o de sistemas dispersos com menores valores nas propriedades reol?gicas e de filtrado. Ambos os sistemas apresentaram ganho de estabilidade t?rmica, mantendo os par?metros reol?gicos est?veis. Os resultados foram ainda corroborados atrav?s de ensaios de inchamento linear de argila. / The advance of drilling in deeper wells has required more thermostable materials. The use of synthetic fluids, which usually have a good chemical stability, faces the environmental constraints, besides it usually generate more discharge and require a costly disposal treatment of drilled cuttings, which are often not efficient and require mechanical components that hinder the operation. The adoption of aqueous fluids generally involves the use of chrome lignosulfonate, used as dispersant, which provides stability on rheological properties and fluid loss under high temperatures and pressures (HTHP). However, due to the environmental impact associated with the use of chrome compounds, the drilling industry needs alternatives that maintain the integrity of the property and ensure success of the operation in view of the strong influence of temperature on the viscosity of aqueous fluids and polymers used in these type fluids, often polysaccharides, passives of hydrolysis and biological degradation. Therefore, vinyl polymers were selected for this study because they have predominantly carbon chain and, in particular, polyvinylpyrrolidone (PVP) for resisting higher temperatures and partially hydrolyzed polyacrylamide (PHPA) and clay by increasing the system's viscosity. Moreover, the absence of acetal bonds reduces the sensitivity to attacks by bacteria. In order to develop an aqueous drilling fluid system for HTHP applications using PVP, HPAM and clay, as main constituents, fluid formulations were prepared and determined its rheological properties using rotary viscometer of the Fann, and volume filtrate obtained by filtration HTHP following the standard API 13B-2. The new fluid system using polyvinylpyrrolidone (PVP) with high molar weight had higher viscosities, gels and yield strength, due to the effect of flocculating clay. On the other hand, the low molecular weight PVP contributed to the formation of disperse systems with lower values in the rheological properties and fluid loss. Both systems are characterized by thermal stability gain up to around 120 ? C, keeping stable rheological parameters. The results were further corroborated through linear clay swelling tests.
48

Avalia??o e modelagem reol?gica de fluido de perfura??o base ?gua

Melo, Klismeryane Costa de 12 September 2008 (has links)
Made available in DSpace on 2014-12-17T15:01:15Z (GMT). No. of bitstreams: 1 klismeryaneCM.pdf: 1762215 bytes, checksum: 0f44499c3657d68cb30deaeefdc7e534 (MD5) Previous issue date: 2008-09-12 / The determination of the rheology of drilling fluids is of fundamental importance to select the best composition and the best treatment to be applied in these fluids. This work presents a study of the rheological behavior of some addictives used as viscosifiers in water-based drilling fluids. The evaluated addictives were: Carboxymethylcellulose (CMC), Xanthan gum (GX), and Bentonite. The main objective was to rheologically characterize suspensions composed by these addictives, by applying mathematical models for fluid flow behavior, in order to determine the best flow equation to represent the system, as well as the model parameters. The mathematical models applied in this research were: the Bingham Model, the Ostwald de Wale Model, and the Herschel-Bulkley Model. A previous study of hydration time for each used addictive was accomplished seeking to evaluate the effect of polymer and clay hydration on rheological behavior of the fluid. The rheological characterization was made through typical rheology experiments, using a coaxial cylinder viscosimeter, where the flow curves and the thixotropic magnitude of each fluid was obtained. For each used addictive the rheological behavior as a function of temperature was also evaluated as well as fluid stability as a function of the concentration and kind of addictive used. After analyses of results, mixtures of polymer and clay were made seeking to evaluate the rheological modifications provided by the polymer incorporation in the water + bentonite system. The obtained results showed that the Ostwald de Waale model provided the best fit for fluids prepared using CMC and for fluids with Xanthan gum and Bentonite the best fit was given by the Herschel-Bulkley one / A determina??o do comportamento reol?gico dos fluidos de perfura??o ? de fundamental import?ncia para se determinar a melhor composi??o e o melhor tratamento a ser aplicado nesses fluidos. Este trabalho apresenta um estudo sobre o comportamento reol?gico de aditivos utilizados como viscosificantes em fluidos de perfura??o de base ?gua. Os aditivos de estudo deste trabalho foram a Carboximetilcelulose (CMC), a Goma Xantana (GX) e a Bentonita. O objetivo principal foi caracterizar reologicamente suspens?es compostas por esses aditivos, atrav?s da aplica??o de modelos matem?ticos para comportamento de fluxo de fluido, a fim de se determinar a melhor equa??o de fluxo que representa o sistema, bem como os par?metros de modelo. Os modelos matem?ticos aplicados foram o modelo de Bingham, o de Ostwald de Waale e o de Herschel-Bulkley. A fim de se verificar o efeito da hidrata??o dos pol?meros e da argila na reologia do fluido realizou-se um estudo pr?vio do tempo de hidrata??o de cada aditivo. A caracteriza??o reol?gica foi realizada atrav?s de ensaios de reologia, utilizando sistema de cilindros coaxiais, onde se obteve as curvas de fluxo e a magnitude tixotr?pica de cada fluido. A reologia foi avaliada, tamb?m, em fun??o da temperatura para cada um dos aditivos utilizados. Foi realizado, ainda, ensaios de estabilidade em fun??o da concentra??o e do aditivo utilizado. Ap?s an?lises de resultados misturas de pol?mero e argila foram formuladas com o objetivo de avaliar as modifica??es reol?gicas proporcionadas pela incorpora??o do pol?mero no sistema ?gua+ bentonita. Os resultados obtidos mostraram que para fluidos preparados com CMC o modelo que melhor representou este sistema foi o de Ostwald de Waale e para os fluidos preparados com GX e Bentonita o modelo que melhor representou foi o de Herschel-Bulkley
49

Utiliza??o De Pol?meros ? Base De Acrilamida Na Remo??o De Cobre De Meio Aquoso / Copper Removal by Focculation Using Anionic Organic Acrylamide-based Polymers

Nunes, Aquiles Filgueira 28 August 2012 (has links)
Made available in DSpace on 2014-12-17T15:01:30Z (GMT). No. of bitstreams: 1 AquilesFN_DISSERT.pdf: 1366110 bytes, checksum: fd8cbc3ddd324f0af2893522b5c9997e (MD5) Previous issue date: 2012-08-28 / Environmental Laws and Regulations to dump wastewater are increasingly relevant and, together with pressure from environmentalists, provide awareness of academics in search of solutions. In Brazil, federal law, through Resolution No. 357 of 17/03/05 of the National Environmental Council - CONAMA, in Article 24 deals with the disposal of these effluents. Water pollution with heavy metals is concern because of the difficulty of the treatment and removal from the environment. Copper, for example, is a metallic element and in the form of salt is very soluble in water which dificults its removal. In this context, this study aims to evaluate the extraction of copper with acrylamide polymers through the process of assisted flocculation followed by filtration. Therefore, we used acrylamide polymers, produced by SNF Floerger, with varying degrees of ionicity which is the parameter examined on the extraction of copper. We used the FA polymers FA 920 SH, AH 912 SH, AN 905 SH, AN 910 SH, AN 923 SH, AN 945 SH, AN 956 SH and AN 977 SH, which have anionicities different from each other and growing in that order. The parameters temperature, pH, concentration of the copper solution and stirring speed are fixed. The polymer solution was added to a solution of 200 ppm copper, varying the concentration of polymer. After stirring, an assisted flocculation occurred followed by filtration of the effluent. The filtrate was analyzed by atomic absorption spectrophotometer and the percentage removal of copper ranged from 63 % to 97 %, noting that polymers with higher ionic charge were responsible for the highest percentage of copper extraction. The results of this study showed that these polymers can be applied in the treatment of wastewaters containing metals such as copper / As Leis e Normas ambientais de despejo de efluentes est?o cada vez mais aplic?veis e, juntamente com a press?o dos ambientalistas, proporcionam a consci?ncia de acad?micos em busca de solu??es. No Brasil, a legisla??o federal, atrav?s da Resolu??o n? 357, de 17/03/05 do Conselho Nacional do Meio Ambiente CONAMA, no Artigo 24, trata do descarte destes efluentes. A contamina??o da ?gua com metais pesados ? uma preocupa??o em virtude da dificuldade de tratamento e remo??o do ambiente. O cobre, por exemplo, ? um elemento met?lico e sob a forma de sal ? bastante sol?vel em ?gua o que termina por dificultar sua remo??o. Nesse contexto, o presente trabalho tem como objetivo avaliar a extra??o do cobre com pol?meros a base de acrilamida atrav?s do processo de flocula??o seguido de filtra??o. Para tanto foram utilizados pol?meros a base de acrilamida, fornecidos pela SNF Floerger, com v?rios graus de ionicidade, que ? o par?metro analisado sobre a extra??o do cobre. Foram utilizados os pol?meros FA 920 SH, AH 912 SH, AN 905 SH, AN 910 SH, AN 923 SH, AN 945 SH, AN 956 SH e AN 977 SH, que apresentam anionicidades diferentes entre si e crescente nessa ordem. Os par?metros temperatura, pH, concentra??o da solu??o de cobre e velocidade de agita??o foram fixados. A solu??o do pol?mero foi adicionada ? solu??o do cobre a 200 ppm, variando a concentra??o de pol?mero. Ap?s a agita??o, ocorreu uma flocula??o assistida e em seguida filtra??o do efluente. O filtrado foi analisado no espectrofot?metro de absor??o at?mica e o percentual de remo??o de cobre variou entre 63% a 97%, observando-se que os pol?meros com maior carga i?nica foram os respons?veis pelo maior percentual de extra??o de cobre. Os resultados obtidos neste trabalho mostraram que ? poss?vel aplicar esses pol?meros no tratamento de efluentes contendo metais como o cobre ou similares
50

Os Pol?meros como Sistemas Complexos

R?go, H?nio Henrique Aragao 11 April 2001 (has links)
Made available in DSpace on 2014-12-17T15:14:31Z (GMT). No. of bitstreams: 1 HenioHAR_tese.pdf: 2852565 bytes, checksum: 647b955f27dbfb55fd62c197b8d3bf55 (MD5) Previous issue date: 2001-04-11 / Neste trabalho, atrav?s de simula??es computacionais, identificamos os fen?menos f?sicos associados ao crescimento e a din?mica de pol?meros como sistemas complexos exibindo comportamentos n?o linearidades, caos, criticalidade auto-organizada, entre outros. No primeiro cap?tulo, iniciamos com uma breve introdu??o onde descrevemos alguns conceitos b?sicos importantes ao entendimento do nosso trabalho. O cap?tulo 2 consiste na descri??o do nosso estudo da distribui??o de segmentos num pol?mero ramificado. Baseado em c?lculos semelhantes aos usados em cadeias polim?ricas lineares, utilizamos o modelo de crescimento para pol?meros ramificados (Branched Polymer Growth Model - BPGM) proposto por Lucena et al., e analisamos a distribui??o de probabilidade dos mon?meros num pol?mero ramificado em 2 dimens?es, at? ent?o desconhecida. No cap?tulo seguinte estudamos a classe de universalidade dos pol?meros ramificados gerados pelo BPGM. Utilizando simula??es computacionais em 3 dimens?es do modelo proposto por Lucena et al., calculamos algumas dimens?es cr?ticas (dimens?es fractal, m?nima e qu?mica) para tentar elucidar a quest?o da classe de universalidade. Ainda neste Cap?tulo, descrevemos um novo modelo para a simula??o de pol?meros ramificados que foi por n?s desenvolvido de modo a poupar esfor?o computacional. Em seguida, no cap?tulo 4 estudamos o comportamento ca?tico do crescimento de pol?meros gerados pelo BPGM. Partimos de pol?meros criticamente organizados e utilizamos uma t?cnica muito semelhante aquela usada em transi??es de fase em Modelos de Ising para estudar propaga??o de danos chamada de Dist?ncia de Hamming. Vimos que a dist?ncia de Hamming para o caso dos pol?meros ramificados se comporta como uma lei de pot?ncia, indicando um car?ter n?o-extensivo na din?mica de crescimento. No Cap?tulo 5 analisamos o movimento molecular de cadeias polim?ricas na presen?a de obst?culos e de gradientes de potenciais. Usamos um modelo generalizado de repta??o para estudar a difus?o de pol?meros lineares em meios desordenados. Investigamos a evolu??o temporal destas cadeias em redes quadradas e medimos os tempos caracter?sticos de transporte t. Finalizamos esta disserta??o com um cap?tulo contendo a conclus?o geral denoss o trabalho (Cap?tulo 6), mais dois ap?ndices (Ap?ndices A e B) contendo a fenomenologia b?sica para alguns conceitos que utilizaremos ao longo desta tese (Fractais e Percola??o respectivamente) e um terceiro e ?ultimo ap?ndice (Ap?ndice C) contendo uma descri??o de um programa de computador para simular o crescimentos de pol?meros ramificados em uma rede quadrada

Page generated in 0.03 seconds