• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 716
  • 13
  • 13
  • 13
  • 13
  • 8
  • 5
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 723
  • 723
  • 430
  • 358
  • 213
  • 137
  • 94
  • 92
  • 84
  • 84
  • 82
  • 81
  • 79
  • 79
  • 72
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Menopausa e fatores de risco associados a doença cardiovascular : um estudo de coorte longitudinal

Raskin, Diana Beatriz Fili 04 August 2005 (has links)
Orientador: Aarão Mendes Pinto Neto / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-04T04:22:14Z (GMT). No. of bitstreams: 1 Raskin_DianaBeatrizFili_D.pdf: 424097 bytes, checksum: bc986c35585d9dbb517a62d685a181f5 (MD5) Previous issue date: 2005 / Resumo: Objetivos: conhecer as características epidemiológicas, antropométricas e comportamentais de mulheres climatéricas, avaliar as variações da pressão arterial, do perfil lipídico e da glicemia de jejum no primeiro, segundo e terceiro anos de acompanhamento tendo como referência os valores iniciais. Conhecer os fatores associados às variações da pressão arterial das dosagens do perfil lipídico e da glicemia de jejum. Métodos: foi realizado estudo de corte longitudinal, com pacientes entre 45 e 65 anos, acompanhadas durante três anos no Ambulatório de Climatério do Hospital Celso Pierro na Faculdade de Medicina da Pontifícia Universidade Católica de Campinas, de 01 de março de 2000 a 11 de março de 2003. Foram consideradas variáveis independentes a idade, cor, status menopausal, tempo de menopausa; índice de massa corpórea e o perfil de distribuição da gordura. O estilo de vida e hábitos: atividade física regular, tabagismo, tipo de dieta e etilismo; o uso e tempo de uso de terapia hormonal e a utilização de outros medicamentos, bem como os antecedentes pessoais e familiares de risco cardiovascular. Os fatores de risco associados à doença cardiovascular e a média de suas variações foram definidos como variáveis dependentes: as pressões arteriais sistólica e diastólica, o colesterol total e frações, os triglicérides, as razões preditoras de risco cardiovascular e a glicemia de jejum. Foram considerados os valores numéricos de aferições de pressão arterial e de resultados de testes laboratoriais de dosagens plasmáticas, realizados e solicitados no primeiro atendimento (T0) e após um (T1), dois (T2) e três anos (T3) de acompanhamento. A análise estatística foi efetuada com medidas de freqüência, médias, variações das médias e desvio padrão. Utilizaram-se os testes T para médias (bicaudal) e qui-quadrado de Pearson com nível de significância de 0,05. Finalmente, foram realizados a análise múltipla por modelo de regressão logística e o processo de seleção Stepwise, com cálculo de Odds ratio e intervalo de confiança a 95%. Resultados: inicialmente, mais de dois terços das mulheres apresentaram sobrepeso (35,7%) e obesidade (33,2%) com perfil andróide (89,0%). Eram brancas (66,1%), pós-menopausadas (63,3%) e sedentárias (64,9%). Um quinto era tabagista (16,1%) e 3,4% etilista. Metade das participantes relatou dieta inadequada (48,8%) e uso de terapia hormonal (60,8%). Mais de 40,0% eram hipertensas e apresentavam razão colesterol total / HDL colesterol maior que 4,0. Um terço das mulheres era portadora de hipercolesterolemia, hipertrigliceremia e razão LDL / HDL colesterol maior que 3,5. Somente 5,3% eram diabéticas. Não houve variação significativa das médias das pressões arteriais sistólica e diastólica, porém observou-se diminuição significativa das médias do colesterol total e frações, dos triglicérides, das razões colesterol total/HDL colesterol, LDL/HDL colesterol, da glicemia de jejum e aumento das médias do HDL colesterol quando comparadas as variações médias do terceiro ano às iniciais. Referir atividade física e dieta inadequadas, não uso de terapia hormonal, hábito de fumar e história familiar de hipertensão arterial e doença cardiovascular; apresentar cor não branca e relatar uso de hipotensor foram as características associadas ao aumento das variações médias do colesterol total e frações, triglicérides e glicemia de jejum e ao não aumento das variações médias do HDL colesterol. Conclusão: nesta população de mulheres observou-se elevado porcentual de fatores de risco associados à doença cardiovascular. As variações constatadas no perfil lipídico e na glicemia de jejum estiveram associadas, principalmente, ao sedentarismo e dieta inadequada, ao não uso da terapia hormonal e ao antecedente pessoal de diabetes como fator protetor / Abstract: Objectives: to understand epidemiological, anthropometric and behavioral characteristics of climacteric women, evaluate variations in blood pressure, lipid profile and fasting plasma glucose level in the first, second and third years of follow-up, using baseline values as reference. To have knowledge of factors associated with variations in blood pressure, lipid profile measurements and fasting plasma glucose. Methods: a co-hort longitudinal study was conducted on patients aged between 45 and 65 years, with a follow-up of three years, at the Climacteric Outpatient Facility in the Celso Pierro Hospital of the Catholic University School of Medicine from March 01, 2000 to March 11, 2003. Independent variables were age, color, menopausal status, length of menopause; body mass index and fat distribution profile. Lifestyle and habits: regular exercise, smoking, diet and alcoholism; use and length of hormone therapy use and use of other medications, as well as a personal and family history of cardiovascular risk. The risk factors associated with cardiovascular disease and mean variations were defined as dependent variables: systolic and diastolic pressure, total and fractionated cholesterol, triglycerides, predictive ratios of cardiovascular risk and fasting plasma glucose. Numerical values of blood pressure measurements and laboratory results of plasma levels performed at the first visit (T0) and those obtained after one (T1), two (T2) and three years (T3) of follow-up were considered. Statistical analysis was performed with measures of rates, means, mean variations and standard deviations. The t tests (two-tailed) and Pearson¿s chi-square with a significance level of 0.05 were used for the mean values. Finally, we performed multiple analysis using a logistic regression model and a stepwise selecting process with odds ratio calculation and 95% confidence interval. Results: more than two-thirds of women were overweight (35.7%) and obese (33.2%) with android profile (89.0%). They were white (66.1%), postmenopausal (63.3%) and sedentary (64.9%). One-fifth of women were smokers (16.1%) and 3.4% were alcoholics. Half of participants reported having an inadequate diet (48.8%) and receiving hormone therapy (60.8%). More than 40.0% of women were hypertensive and total cholesterol/HDL cholesterol ratio was higher than 4.0. One-third of women had hypercholesterolemia, hypertriglyceridemia and an LDL/HDL cholesterol ratio higher than 3.5. Only 5.3% of women had diabetes. There was no significant variation in mean systolic and diastolic blood pressure. However, there was a significant reduction in mean total and fractionated cholesterol, triglycerides, total cholesterol/HDL cholesterol ratio, LDL/HDL ratio, fasting plasma glucose and increased mean HDL cholesterol when mean variations of the third year were compared to those of baseline values. Exercise and inadequate diet, non-use of hormone therapy, smoking habit and family history of arterial hypertension and cardiovascular diesease; non-white color and the use of hypotensive agent were characteristics associated with increased mean variations of total and fractionated cholesterol, triglycerides and fasting plasma glucose and no increase in mean variations of HDL cholesterol. Conclusion: in this female population, a high percentage of risk factors associated with cardiovascular disease was observed. Variations in lipid profile and fasting plasma glucose were primarily associated with a sedentary lifestyle and inadequate diet, non-use of hormone therapy and a personal history of diabetes as protective factor / Doutorado / Tocoginecologia / Doutor em Tocoginecologia
112

Estudo da filtração glomerular e da manipulação tubular renal de sodio em animais normotensos e hipertensos submetidos a injeção intracerebroventricular de solução salina hipertonica : influencia da denervação renal bilateral

Guadadgnini, Dioze 28 February 2005 (has links)
Orientador: Jose Antonio Rocha Gontijo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-04T06:42:03Z (GMT). No. of bitstreams: 1 Guadadgnini_Dioze_M.pdf: 41519397 bytes, checksum: 78181c9927d4531f49330b384c4cf7ba (MD5) Previous issue date: 2005 / Resumo: o mecanismo pelo qual o aumento da pressão sanguínea em grupos de ratos espontaneamente hipertensos (SHR) se estabelece, não foi totalmente esclarecido. Além disso, há uma surpreendente falta de dados experimentais sobre os mecanismos natriuréticos induzidos pela injeção intracerebroventricular (i.c.v.) de salina hipertônica em SHR. No presente estudo, realça-se a hipótese de que a hipertensão em SHR pode ser resultado, pelo menos em parte, da contínua superatividade do nervo simpático renal, causada pela menor resposta central frente ao aumento da concentração de sódio no fluido cerebroespinal. Para testar esta hipótese, o estudo foi projetado para avaliar a influência da atividade nervosa renal, após injeção i.c.v. de salina hipertônica de concentrações crescentes sobre o manuseio renal de sódio urinário em SHR submetidos à denervação renal bilateral comparados a seus respectivos controles Wistar Kyoto (WKy). A presente investigação confirmou estudos anteriores, mostrando pronunciada resposta natriurética renal pós-injeção central de salina hipertônica, mas também demonstrou redução na taxa de filtração glomerular, estimado pelo "Clearance" de Creatinina endógena (Cer) associada à menor fração de excreção de sódio (FENa)relacionados à concentração administrada em ratos WKy, mas não nos SHR. Nos SHR, a elevação da FENafoi obtida somente pela administração central de NaCI na concentração de O.90M.Este resultado foi conseqüência da rejeição à reabsorção de sódio nos segmentos tubulares proximais (FEPNa) e pósproximais (FEPPNa) do nefro, sem entretanto, qualquer modificação do Ccr. Estes resultados indicam que os mecanismos envolvidos em tal resposta estão relacionados ao efeito direto sobre os segmentos tubulares do nefro. A denervação renal causou um significante efeito antinatriurético secundário, possivelmente, à diminuição do Ccr e à elevada reabsorção de sódio na porção proximal dos túbulos (FEPNa)renais em ratos WKy, mas não em SHR. Um aspecto novo do presente estudo mostrou que em animais normotensos, a natriurese está diretamente associada ao aumento do Ccr e à menor reabsorção proximal de sódio, resultando em maior aporte de íons aos segmentos distais no nefro. A reabsorção desta elevada carga dista! de íons, e fluxo dos segmentos proximais, não é completamente compensada por estes segmentos pós-proximais do nefro. Adicionalmente, a elevação da FENaem SHR somente após injeção i.c.v. de elevada concentração de salina (O.90MNaCI), com um desvio para a direita da curva concentraçãoresposta, sugere a possibilidade de que estes animais apresentem atenuação da resposta, via receptores centrais circunventriculares, à concentrações de sódio em SHR, quando comparados a ratos WKy. Estes resultados poderiam estar relacionados à diminuição do número e/ou ao "downregulation" na área de sinalização de receptores de sódio em regiões periventriculares. Conseqüentemente, esta menor sensibilidade central estaria relacionada com a resposta pressórica inadequada e atenuada resposta neuro-humoral na linhagem SHR / Abstract: The mechanism by which blood pressure has risen in the spontaneously hypertensive rats (SHR) strain remains to be elucidated. Besides, there is a surprising lack of experimental data on the natriuretic mechanisms induced by intracerebroventricular (i.c.v.) injection of hypertonic saline in SHR. In the current study, we have hypothesized that SHR hypertension may result, at least in part, :ITom sustained renal sympathetic nerve overactivity caused by decreased central response to elevated cerebrospinal fluid sodium concentration. To test this hypothesis, the study was designed to evaluate the influence of renal denervation activity after i.c.v. hypertonic saline injection at increasing concentration on renal urinary sodium handling in SHR compared with appropriate age-matched Wistar Kyoto (WKy) control subjects. The present investigation has confirmed previous data showing pronounced renal natriuretic response to i.c.v. hypertonic saline stimuli but, also, it has demonstrated a decreased creatinine clearance (Cer) and :ITactionalsodium excretion (FENa)in a concentration-dependent manner in WKy rats but not in SHR. In SHR, it has increased FENaobtained by centrally administration of concentration of O.90MNaCI. This result was produced by increases in proximal (FEPNa) and post-proximal (FEPPNa) fractional urinary sodium rejection without presenting changes in CCr, indicating a direct tubular effect. Renal denervation has caused significant antinatriuresis by decreased Ccr and increased FEPNareabsorption in WKy but not in SHR. The novel finding of the present research has shown that natriuresis is associated with an increased Cer and ion delivery :ITomthe proximal tubule and that is incompletely compensated by more distal nephron segments. And, an enhanced FENaonly after higher i.c.v. hypertonic saline (O.90MNaCI) injection with shift to right of dose-response curve provides evidence of a small response of sodium sensor receptors in periventricular areas of SHR compared to WKy rats. This may be interpretedas a down-regulation of target organ responsiveness to small concentrations of NaCI and/or that inappropriately decrease in the responsiveness would be related to impairment ofblood pressure response and neuro-humoral factors release in SHR strain / Mestrado / Medicina Experimental / Mestre em Fisiopatologia Médica
113

Fatores de risco à saúde cardiovascular associados ao sobrepeso e obesidade em crianças e adolescentes

SILVA, Elaine Lima da 31 January 2012 (has links)
Submitted by Heitor Rapela Medeiros (heitor.rapela@ufpe.br) on 2015-03-05T14:26:12Z No. of bitstreams: 2 Elaine_dissert.pdf: 1387591 bytes, checksum: 16dbbfa04806b4279c58c7a366655987 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-05T14:26:12Z (GMT). No. of bitstreams: 2 Elaine_dissert.pdf: 1387591 bytes, checksum: 16dbbfa04806b4279c58c7a366655987 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2012 / A prevalência de sobrepeso e obesidade vem aumentando rapidamente no mundo, sendo considerada um importante problema de saúde pública tanto para países desenvolvidos como em desenvolvimento. A obesidade é uma doença crônica que envolve fatores sociais, comportamentais, nutricionais, hormonais, ambientais, culturais, psicológicos, metabólicos, genéticos e medicamentosos. Caracteriza-se pelo acúmulo de gordura corporal, sendo a responsável direta pela fisiopatogenia das doenças crônicas como o diabetes, arteriosclerose, a hipertensão arterial, as dislipidemias, as doenças arteriais coronárias (DAC). Diante do exposto, a questão que norteou este estudo foi: Qual a prevalência de crianças e adolescentes com sobrepeso e obesidade, estudantes da escola pública Marcelino Champagnat, na região metropolitana do Recife-PE, desenvolverem eventos cardiovasculares precocemente? São os objetivos desse estudo: Analisar a prevalência de sobrepeso e obesidade e os fatores associados ao risco para as doenças cardiovasculares em crianças e adolescentes matriculados na Escola pública Marcelino Champagnat. Os objetivos específicos foram: Avaliar o estado nutricional dos escolares; Descrever e classificar os valores da pressão arterial desses escolares; Investigar os fatores de risco associados a doenças cardiovasculares. Para atingir tais objetivos, foi utilizado o método quantitativo, descritivo de corte transversal. Essa dissertação está constituída por um capítulo de Revisão Integrativa: “Cardioproteção em crianças e adolescentes com excesso de peso e pressão arterial elevada: uma revisão integrativa”, que foi publicado em um capítulo de livro. E um artigo original, decorrente da pesquisa realizada com 125 escolares de 7 a 17 anos, da escola Marcelino Champagnat no período de Julho a Setembro de 2011. Foram utilizadas a estatística descritiva e inferencial, através do teste Qui-Quadrado e a correção de Yates, considerando significantes os resultados com p<0,05. Como resultado encontrou-se prevalência de sobrepeso de 13,6% e obesidade de 14,4% com níveis mais elevados em meninos do que meninas. Um dado relevante desse estudo foi a predominância de hipertensão arterial na classe etária de 7-12 anos. O fator de risco cardiovascular de maior prevalência encontrado na amostra foi a presença de pressão arterial elevada, a prevalência de pré-hipertensão foi de 14,4% e hipertensão 11,2%, perfazendo um total de 25,6% de escolares com alteração da pressão arterial. O aumento da Relação Cintura Quadril (RCQ) e do Índice de Massa Corpórea (IMC) apresentou associação estatística significante com o aumento da idade. Porém ao levar em consideração que o grupo estudado é de crianças de 7 a 12 anos, pode-se inferir que é elevado o número de indivíduos que deveriam ser acompanhados sistematicamente pelos serviços de saúde. Considerando que a hipertensão arterial é o preditor mais importante da mortalidade cardiovascular e que as desigualdades sociais presentes determinam a sua precocidade, é importante a detecção precoce da alteração da pressão arterial em crianças cujas famílias se encontram em maior risco social. Conclui-se neste estudo que os fatores de risco cardiovascular estão presentes em parcela significativa das crianças estudadas e há uma aglomeração maior destes fatores em crianças de 7 a 9 anos.
114

Comparação das medidas de pressão não invasivas pelos metodos do Doppler e Pos-capilar em membros inferiores : estudo realizado em individuos sem obstruções arteriais

Menezes, Fábio Hüsemann, 1962- 18 July 2018 (has links)
Orientador : João Poterio Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-07-18T07:25:20Z (GMT). No. of bitstreams: 1 Menezes_FabioHusemann_M.pdf: 1388418 bytes, checksum: 62556d72f442c7749bb42113b9309b88 (MD5) Previous issue date: 1993 / Resumo: Desenvolveu-se este estudo para comparar, em membros inferiores, o método Pós-capilar para medida não-invasiva de pressão arterial com o método do Doppler. Foram estudados dois grupos de indivíduos que não apresentavam diferença estatística em relação a sexo, idade e presença de fatores de risco para arteriosclerose: 36 pacientes diabéticos e 37 voluntários sem diabetes mellitus, todos com pulsos presentes nos pés. Mostrou-se que o método Pós-capilar tem correlação com o método do Doppler, mas hipoestima as pressões nos indivíduos com índice pressórico tornozelo/braço (pelo método do Doppler) menor ou igual a 1,2. Nos indivíduos com índice tornozelo/braço (pelo método do Doppler) elevado, o método Pós-capilar estima nos pés pressões mais próximas das pressões dos membros superiores. Conclue-se que o método Pós-capilar não se aplica como substituto ao método do Doppler para a medida de pressão em indivíduos sem endurecimento arterial, mas está indicado nos casos com artérias endurecidas e, especialmente, quando as artérias são incompressíveis, o que torna não confiável a leitura da pressão com o método do Doppler / Abstract: The purpose of this study was to compare the non invasive blood pressure determination techniques of the Doppler and Post-capillary, used for the lower limbs. Two groups of subjects were studied. There was no statistical difference between the groups in regard to sex, age and risk factors for atherosclerosis. The first group consisted of 36 patients with Diabetes Mellitus, and the second group of 37 volunteers with no history of Diabetes. All subjects had palpable pulses at the foot. There could be demonstrated that the Post-capillary technique correlated well with the Doppler in those subjects with a Doppler ankle/brachial index lower or equal to 1. 2, even though the new technique underestimated the pressure in this group. In those subjects with stiffened arteries, with a Doppler ankle/brachial index higher than 1.2, the Post-capillary technique estimated pressure values closer to the arm pressure values. We conclude that the Post-capillary technique can not be used as a substitute for the Doppler technique in those subjects with palpable pulses and without stiffened arteries. Nonetheless i t is indicated for the evaluation of those subjects with stiffened arteries, and it's best indication is for those subjects with calcified arteries, where the Doppler derived pressures can not be trusted / Mestrado / Cirurgia / Mestre em Cirurgia
115

Medida indireta e registro da pressão arterial: práticas adotadas por profissionais de enfermagem / Indirect measurement and recording of blood pressure: practices adopted by members of the nursing profession

Mouro, Douglas Lima 21 August 2014 (has links)
A medida da pressão arterial é um procedimento fundamental para o diagnóstico e controle da hipertensão arterial. O objetivo do presente estudo foi identificar como é realizado o procedimento de medida indireta e registro da pressão arterial por profissionais de enfermagem. Trata-se de estudo quantitativo, observacional, de delineamento transversal. A amostra foi composta por 80 servidores lotados em cinco Unidades de Saúde do município de Londrina-Paraná, sendo 25 (31,3 %) enfermeiros, 24 (30%) técnicos de enfermagem e 31 (38,8 %) auxiliares de enfermagem. Para avaliar como os participantes realizam a medida indireta da pressão arterial, utilizamos como referência um instrumento formulado a partir das etapas para a medida da pressão descritas nas VI Diretrizes Brasileiras de Hipertensão. O registro do procedimento foi avaliado a partir de instrumento construído com base nas recomendações para registros de enfermagem do Conselho Regional de Enfermagem de São Paulo. Também identificamos a qualidade dos dispositivos utilizados para a medida da pressão arterial. Os resultados mostraram altos índices de \"não realização\" (93,8% a 100%) das etapas referentes ao preparo do paciente para a medida da pressão. As etapas relacionadas diretamente à obtenção do valor pressórico apresentaram índices de 3,8% a 100% na categoria \"incorreta\", sendo os piores resultados relacionados a inflação e deflação da bolsa de borracha. As etapas: \"obter a circunferência braquial no ponto médio do braço\" e \"selecionar manguito de tamanho adequado à circunferência do braço\" não foram realizadas por 100% e 96,3% dos participantes, respectivamente. Na sua totalidade, os profissionais se limitaram a registrar o valor da pressão arterial e, na maioria das anotações, não houve identificação do participante pelo registro profissional (96, 3%) ou pela assinatura (93,8%) e não há referência ao horário da anotação (70,9%). Em relação aos equipamentos, a calibração não é aferida na rotina dos serviços e não há disponibilidade de manguitos de tamanhos variados. Esses achados permitem concluir que há importantes lacunas relacionadas à prática adotada pela equipe de enfermagem para a medida da pressão arterial, indicando a necessidade de implementação de medidas educativas / Blood pressure measurement is an essential procedure to the diagnosis and control of hypertension. The aim of this study was to identify how the indirect measurement and recording of blood pressure was performed by members of the nursing profession. This is a quantitative, observational and cross-sectional study with a sample comprised of 80 professional workers from five different Health Centers in the municipality of Londrina, Paraná. Among these professional workers, twenty-five (31,1%) were nurses, 24 (30%) were nurse technicians and 31 (38,8%) were auxiliary nurses. In order to assess the way the participants performed the indirect measurement of blood pressure, a tool which is based on the steps proposed by the 6th Brazilian Guidelines for Hypertension for BP readings was used. In order to assess the recordings made by the workers, it was used a tool which is based on the recommendations put forward by the São Paulo Regional Board of Nursing for recordings in this field. The quality of the devices used for BP measurement was also inspected. The results of this study have showed that a large number of participants (93,8% to 100%) failed to follow the steps concerning the preparation of the patient for the reading. For the steps that were directly related to the measurement of the blood pressure itself, the percentages obtained for the \"incorrect\" category ranged from 3,8% to 100%. The worst results achieved in this case were those related to the inflation and deflation of the rubber bladder. Around 100% of the participants did not contemplate the step \"Obtaining the upper arm circumference at a middle point\" and 96,3% of them did not follow the step \"Choosing the appropriate cuff size for the upper arm circumference\". Most workers only recorded the blood pressure readings, therefore leaving out their professional registers (96,3), their signatures (93,8%) and the time the reading was done (70,9%). The calibration of the devices used in this procedure is not done on regular basis and there is only one size of cuff available. The findings of this study show that there are several important gaps that need to be filled in regard to the procedure adopted by the nursing staff when measuring blood pressure. They also indicate the need to implement professional training
116

Calibre vascular retiniano e a pressão arterial medida por monitoramento ambulatorial da pressão arterial

Pakter, Helena Messinger January 2010 (has links)
É bem conhecido que alterações vasculares iniciam como um processo silencioso e assintomático. A identificação precoce de anormalidades vasculares na retina em pacientes assintomáticos pode permitir a detecção de pacientes em risco de desenvolver DCV. Por prover visualização direta do leito vascular, a retina pode ser estudada não invasivamente mostrando o grau de acometimento da microcirculação. Avanços nas técnicas de fotografia retiniana e de análise digital de imagem tem permitido a mensuração objetiva de alterações vasculares da retina. Com isso, é possível quantificar anormalidades na microvasculatura retiniana, imprescindível para o estudo da fisiopatologia da hipertensão arterial sistêmica, bem como para a avaliação da associação com doença cardiovascular. Um software desenvolvido pela autora desta tese e colaboradores é capaz de medir calibre de arteríolas e vênulas de retinografias digitalizadas. Esse software, nomeado Retinal Analyser System (RAS), foi atualizado e houve a inclusão e testagem de um fator de escala ou calibração, apresentado no Artigo 1 dessa tese. Os métodos de análise de imagens da retina utilizados para medir calibre dos vasos retinianos não determinam exatamente o que está sendo medido. Assim, havia necessidade de investigar se o calibre medido no software RAS corresponde ao lúmen vascular somente ou se inclui a parede vascular. O Artigo 2 dessa tese apresenta a comparação de medidas de calibre de vasos retinianos, em retinografias coloridas com angiografias fluoresceínicas. Nesse artigo concluímos que, como as diferenças encontradas entre os dois métodos foram muito pequenas, o método microdensitométrico mede o lúmen vascular. Os calibres vasculares retinianos avaliados quantitativamente por métodos digitalizados tem mostrado uma associação significativa com incidência e gravidade da hipertensão arterial casual. No entanto, nas últimas décadas, tem sido discutido o valor da medida casual da pressão arterial para fins prognósticos. Em função da variação contínua da pressão arterial, de momento a momento, de acordo com as atividades do indivíduo, novos métodos podem complementar a avaliação através de medidas repetidas da pressão arterial, permitindo a detecção da pressão arterial usual. Tendo em vista essas considerações, o Artigo 3 dessa tese avaliou a associação entre os diferentes parâmetros da pressão arterial, medida pela MAPA, e os calibres vasculares retinianos. A relação entre pressão arterial e calibre arteriolar e venular da retina no momento da obtenção retinografia também foi estudada. Demonstramos que a pressão diastólica média das 24 horas, da vigília e do sono teve associação inversa e significativa com calibre arteriolar e razão arterio-venosa, mas não com calibre venular. A pressão arterial medida na hora da retinografia não mostrou associação com o calibre dos vasos retinianos. Assim concluímos que a associação entre o calibre arteriolar dos vasos retinianos e a pressão arterial não é influenciada pela variação instantânea da pressão arterial e, provavelmente, depende de lesões histológicas da parede arteriolar secundária à hipertensão sustentada. Através da MAPA também é possível avaliarmos a variação temporal da pressão arterial ao longo de um período de 24 horas, e assim estudar o ritmo circadiano e a ritimicidade da pressão arterial. Uma maneira de analisar a ritimicidade da pressão arterial é através do método Cosinor, um método de análise de regressão periódica, baseada na adaptação da função do coseno, para valores da pressão arterial com período de 24 horas. O método Cosinor gera, em cada elemento (indivíduo ou população), os seguintes parâmetros de validação do ritmo circadiano: MESOR (sigla em inglês para média do ritmo ajustada estatísticamente), acrofase e amplitude. O estudo do ritmo circadiano da pressão arterial, avaliado pela da análise de cosinor, e sua associação com os calibres vasculares retinianos, resultou no artigo 4 dessa tese. Nesse artigo, mostramos que o MESOR associa-se significativa e inversamente com calibre arteriolar, com uma magnitude de 0.8 a 1 micron de redução no calibre para um aumento de 10 mmHg do MESOR da pressão arterial. O calibre venular não mostrou associação com o MESOR. Também usamos a análise de Cosinor para população e avaliamos as diferenças nos ritmos da pressão arterial entre as populações do primeiro e dos demais quintis de calibre vascular. Através desta análise observamos que amplitude e acrofase da pressão arterial são estatisticamente diferente entre as populações do primeiro e demais quintis de calibre venoso, mas não arteriolar. Em resumo, enquanto o MESOR está associado ao calibre arteriolar, a amplitude e a acrofase estão associadas ao calibre venular. Concluindo, essa tese mostra, através de seus 4 artigos, a aplicação do software RAS para medida de calibres vasculares retinianos e a associação dessas medidas com pressão arterial, em uma população de pacientes hipertensos. A associação entre o calibre vascular retiniano, a pressão arterial medida 24 horas e o seu ritmo, demonstrada nessa tese, fortalece a hipótese que a avaliação da microvasculatura retiniana pode ser um marcador clínico importante de lesão em órgão. / It is well known that vascular changes begin as a silent and asymptomatic process. Early identification of retinal vascular abnormalities in asymptomatic patients may allow the detection of patients at risk. By providing unique visualization of the vascular bed, the retina can be studied no invasively and show the degree of microcirculation involvement. Advances in techniques of retinal photography and digital image analysis have allowed objective measurement of retinal vascular changes. Thus, it is possible to quantify abnormalities in the retinal microvasculature, essentially to study hypertension pathophysiology, and to assess its association to cardiovascular disease. Software developed by our research group is able to measure the caliber of arterioles and venules of digitized fundus. This software, named Retinal Analyzer System (RAS), has been updated by including and testing a scale factor, presented in Article 1 of this thesis. The current methods of image analysis used to measure the caliber of retinal vessels do not determine exactly what is being measured. Thus there was need to investigate whether the caliber measured in RAS software corresponds to the vascular lumen only or whether it includes the vascular wall. Article 2 of this thesis presents a comparison of the measurements of retinal vessels calibers in color fundus photography to those in fluorescein angiography. In this article we show that the differences found between the two methods were very small, and concluded that the microdensitometry method measures mainly the vascular lumen. The retinal vascular calibers measured quantitatively by microdensitometric methods have shown a significant association with incidence and severity of hypertension. However, studies evaluating these associations are based on casual blood pressure and, in recent decades, it has been discussed the value of casual blood pressure measurement. In light of continuous variation in blood pressure from moment to moment, according to the individual's activities, new methods can complement the assessments through repeated measurements of blood pressure, allowing the detection of usual blood pressure. Given these considerations, Article 3 of this thesis examined the association between different parameters of the blood pressure measured by ABPM, and retinal vascular caliber. The relationship between blood pressure at the time of retinography acquisition and retinal arteriolar and venular caliber was also studied. We show that the mean 24 hours, daytime and night time diastolic blood pressure were significantly and inversely associated with arteriolar caliber and arteriovenous ratio, but not with venular caliber. The pressure measured at the time of acquisition of the fundus showed no association with the caliber of retinal vessels, thus the association between arteriolar retinal vessels caliber and blood pressure is not influenced by instantaneous variation of blood pressure and probably depends of histological damage of arteriolar wall secondary to sustained hypertension. Using ABPM is also possible to evaluate the temporal variation of blood pressure over a period of 24 hours, and then study the circadian rhythm of blood pressure. One way to analyze the blood pressure rhythm is using the Cosinor method, a method of periodic regression analysis, based on the adaptation of the cosine function, for values of blood pressure with 24-hour period. The method Cosinor generates the following validation parameters of the circadian rhythm: MESOR (acronym for "Midline Estimated Statistic Of Rhythm"), acrophase and amplitude. The study of circadian rhythm of blood pressure, as assessed by analysis COSINOR and its association with retinal vascular caliber, resulted in Article 4 of this thesis. In this paper we show that MESOR is associated significantly and inversely with arteriolar caliber, with a magnitude of 0.8 to 1 micron reduction to an increase of 10 mmHg of blood pressure MESOR. The venular caliber was not associated with MESOR. We also use the Cosinor analysis to study differences in the rhythms of blood pressure among populations in the first quintile and the rest quintiles of vascular caliber. Through this analysis we found that amplitude and acrophase of blood pressure were statistically different between the populations of the first and the other quintiles of venous caliber, but not arterioles. In conclusion, this thesis shows, through its four articles, the application of RAS software to measure retinal vascular caliber and the association of these measurements with blood pressure in a population of hypertensive patients. The association between retinal vascular calibers, blood pressure measured 24 hours and rhythm, as demonstrated in this thesis, strengthens the hypothesis that assessment of the retinal microvasculature may be an important clinical marker of organ damage.
117

Calibre vascular retiniano e a pressão arterial medida por monitoramento ambulatorial da pressão arterial

Pakter, Helena Messinger January 2010 (has links)
É bem conhecido que alterações vasculares iniciam como um processo silencioso e assintomático. A identificação precoce de anormalidades vasculares na retina em pacientes assintomáticos pode permitir a detecção de pacientes em risco de desenvolver DCV. Por prover visualização direta do leito vascular, a retina pode ser estudada não invasivamente mostrando o grau de acometimento da microcirculação. Avanços nas técnicas de fotografia retiniana e de análise digital de imagem tem permitido a mensuração objetiva de alterações vasculares da retina. Com isso, é possível quantificar anormalidades na microvasculatura retiniana, imprescindível para o estudo da fisiopatologia da hipertensão arterial sistêmica, bem como para a avaliação da associação com doença cardiovascular. Um software desenvolvido pela autora desta tese e colaboradores é capaz de medir calibre de arteríolas e vênulas de retinografias digitalizadas. Esse software, nomeado Retinal Analyser System (RAS), foi atualizado e houve a inclusão e testagem de um fator de escala ou calibração, apresentado no Artigo 1 dessa tese. Os métodos de análise de imagens da retina utilizados para medir calibre dos vasos retinianos não determinam exatamente o que está sendo medido. Assim, havia necessidade de investigar se o calibre medido no software RAS corresponde ao lúmen vascular somente ou se inclui a parede vascular. O Artigo 2 dessa tese apresenta a comparação de medidas de calibre de vasos retinianos, em retinografias coloridas com angiografias fluoresceínicas. Nesse artigo concluímos que, como as diferenças encontradas entre os dois métodos foram muito pequenas, o método microdensitométrico mede o lúmen vascular. Os calibres vasculares retinianos avaliados quantitativamente por métodos digitalizados tem mostrado uma associação significativa com incidência e gravidade da hipertensão arterial casual. No entanto, nas últimas décadas, tem sido discutido o valor da medida casual da pressão arterial para fins prognósticos. Em função da variação contínua da pressão arterial, de momento a momento, de acordo com as atividades do indivíduo, novos métodos podem complementar a avaliação através de medidas repetidas da pressão arterial, permitindo a detecção da pressão arterial usual. Tendo em vista essas considerações, o Artigo 3 dessa tese avaliou a associação entre os diferentes parâmetros da pressão arterial, medida pela MAPA, e os calibres vasculares retinianos. A relação entre pressão arterial e calibre arteriolar e venular da retina no momento da obtenção retinografia também foi estudada. Demonstramos que a pressão diastólica média das 24 horas, da vigília e do sono teve associação inversa e significativa com calibre arteriolar e razão arterio-venosa, mas não com calibre venular. A pressão arterial medida na hora da retinografia não mostrou associação com o calibre dos vasos retinianos. Assim concluímos que a associação entre o calibre arteriolar dos vasos retinianos e a pressão arterial não é influenciada pela variação instantânea da pressão arterial e, provavelmente, depende de lesões histológicas da parede arteriolar secundária à hipertensão sustentada. Através da MAPA também é possível avaliarmos a variação temporal da pressão arterial ao longo de um período de 24 horas, e assim estudar o ritmo circadiano e a ritimicidade da pressão arterial. Uma maneira de analisar a ritimicidade da pressão arterial é através do método Cosinor, um método de análise de regressão periódica, baseada na adaptação da função do coseno, para valores da pressão arterial com período de 24 horas. O método Cosinor gera, em cada elemento (indivíduo ou população), os seguintes parâmetros de validação do ritmo circadiano: MESOR (sigla em inglês para média do ritmo ajustada estatísticamente), acrofase e amplitude. O estudo do ritmo circadiano da pressão arterial, avaliado pela da análise de cosinor, e sua associação com os calibres vasculares retinianos, resultou no artigo 4 dessa tese. Nesse artigo, mostramos que o MESOR associa-se significativa e inversamente com calibre arteriolar, com uma magnitude de 0.8 a 1 micron de redução no calibre para um aumento de 10 mmHg do MESOR da pressão arterial. O calibre venular não mostrou associação com o MESOR. Também usamos a análise de Cosinor para população e avaliamos as diferenças nos ritmos da pressão arterial entre as populações do primeiro e dos demais quintis de calibre vascular. Através desta análise observamos que amplitude e acrofase da pressão arterial são estatisticamente diferente entre as populações do primeiro e demais quintis de calibre venoso, mas não arteriolar. Em resumo, enquanto o MESOR está associado ao calibre arteriolar, a amplitude e a acrofase estão associadas ao calibre venular. Concluindo, essa tese mostra, através de seus 4 artigos, a aplicação do software RAS para medida de calibres vasculares retinianos e a associação dessas medidas com pressão arterial, em uma população de pacientes hipertensos. A associação entre o calibre vascular retiniano, a pressão arterial medida 24 horas e o seu ritmo, demonstrada nessa tese, fortalece a hipótese que a avaliação da microvasculatura retiniana pode ser um marcador clínico importante de lesão em órgão. / It is well known that vascular changes begin as a silent and asymptomatic process. Early identification of retinal vascular abnormalities in asymptomatic patients may allow the detection of patients at risk. By providing unique visualization of the vascular bed, the retina can be studied no invasively and show the degree of microcirculation involvement. Advances in techniques of retinal photography and digital image analysis have allowed objective measurement of retinal vascular changes. Thus, it is possible to quantify abnormalities in the retinal microvasculature, essentially to study hypertension pathophysiology, and to assess its association to cardiovascular disease. Software developed by our research group is able to measure the caliber of arterioles and venules of digitized fundus. This software, named Retinal Analyzer System (RAS), has been updated by including and testing a scale factor, presented in Article 1 of this thesis. The current methods of image analysis used to measure the caliber of retinal vessels do not determine exactly what is being measured. Thus there was need to investigate whether the caliber measured in RAS software corresponds to the vascular lumen only or whether it includes the vascular wall. Article 2 of this thesis presents a comparison of the measurements of retinal vessels calibers in color fundus photography to those in fluorescein angiography. In this article we show that the differences found between the two methods were very small, and concluded that the microdensitometry method measures mainly the vascular lumen. The retinal vascular calibers measured quantitatively by microdensitometric methods have shown a significant association with incidence and severity of hypertension. However, studies evaluating these associations are based on casual blood pressure and, in recent decades, it has been discussed the value of casual blood pressure measurement. In light of continuous variation in blood pressure from moment to moment, according to the individual's activities, new methods can complement the assessments through repeated measurements of blood pressure, allowing the detection of usual blood pressure. Given these considerations, Article 3 of this thesis examined the association between different parameters of the blood pressure measured by ABPM, and retinal vascular caliber. The relationship between blood pressure at the time of retinography acquisition and retinal arteriolar and venular caliber was also studied. We show that the mean 24 hours, daytime and night time diastolic blood pressure were significantly and inversely associated with arteriolar caliber and arteriovenous ratio, but not with venular caliber. The pressure measured at the time of acquisition of the fundus showed no association with the caliber of retinal vessels, thus the association between arteriolar retinal vessels caliber and blood pressure is not influenced by instantaneous variation of blood pressure and probably depends of histological damage of arteriolar wall secondary to sustained hypertension. Using ABPM is also possible to evaluate the temporal variation of blood pressure over a period of 24 hours, and then study the circadian rhythm of blood pressure. One way to analyze the blood pressure rhythm is using the Cosinor method, a method of periodic regression analysis, based on the adaptation of the cosine function, for values of blood pressure with 24-hour period. The method Cosinor generates the following validation parameters of the circadian rhythm: MESOR (acronym for "Midline Estimated Statistic Of Rhythm"), acrophase and amplitude. The study of circadian rhythm of blood pressure, as assessed by analysis COSINOR and its association with retinal vascular caliber, resulted in Article 4 of this thesis. In this paper we show that MESOR is associated significantly and inversely with arteriolar caliber, with a magnitude of 0.8 to 1 micron reduction to an increase of 10 mmHg of blood pressure MESOR. The venular caliber was not associated with MESOR. We also use the Cosinor analysis to study differences in the rhythms of blood pressure among populations in the first quintile and the rest quintiles of vascular caliber. Through this analysis we found that amplitude and acrophase of blood pressure were statistically different between the populations of the first and the other quintiles of venous caliber, but not arterioles. In conclusion, this thesis shows, through its four articles, the application of RAS software to measure retinal vascular caliber and the association of these measurements with blood pressure in a population of hypertensive patients. The association between retinal vascular calibers, blood pressure measured 24 hours and rhythm, as demonstrated in this thesis, strengthens the hypothesis that assessment of the retinal microvasculature may be an important clinical marker of organ damage.
118

Monitoramento ambulatorial da pressão arterial: variabilidade da pressão, descenso da frequência cardíaca ao sono e risco de eventos fatais na doença renal crônica

Marchi, Daniel [UNESP] 28 February 2014 (has links) (PDF)
Made available in DSpace on 2014-08-13T14:50:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-28Bitstream added on 2014-08-13T17:59:52Z : No. of bitstreams: 1 000771311.pdf: 878354 bytes, checksum: 07ede9fa8d2fa3a56b88f18f5f7c1499 (MD5) / Introdução: Mais da metade das mortes em portadores de doença renal crônica (DRC) são atribuídas à doença cardiovascular. O controle da pressão arterial (PA) é considerado uma estratégia fundamental na redução da morbidade e mortalidade na população renal crônica. A monitorização ambulatorial da pressão arterial (MAPA) tem se mostrado superior à PA de consultório ao definir prognóstico e desfecho em todos os estádios da DRC. Alguns dados obtidos da MAPA ,como a variabilidade da pressão arterial (VPA) e a atenuação do descenso da frequência cardíaca (FC) ao sono, mostraram-se fatores de risco para mortalidade geral e cardiovascular na população hipertensa, porém não há estudos na população com DRC que avaliaram a VPA e o descenso da FC ao sono aferidos pela MAPA. Os objetivos deste estudo foram avaliar o impacto prognóstico da VPA e do descenso da FC ao sono obtidos pela MAPA em renais crônicos. Pacientes e métodos: Estudo longitudinal, observacional e retrospectivo que envolveu a análise de 251 exames de MAPA de indivíduos com DRC realizados no Hospital das Clínicas da Faculdade de Medicina de Botucatu seguidos pela mediana de 34 meses. Resultados: Ao comparar os pacientes que apresentaram desfechos fatais de origem cardiovascular e por todas as causas, com os que não apresentaram desfechos, nota-se idade superior e predominância de estádios mais avançados da DRC. Mesmo após ajuste para estádio da DRC, idade e PP na vigília, o menor descenso da FC ao sono (HR: 0,925 , IC 95% : 0,865 a 0,991, p=0,026) mostrou-se preditor independente de mortalidade cardiovascular. Os resultados não mostraram associação independente entre a VPA, avaliada pelo desvio padrão das pressões, com mortalidade. Conclusão: A VPA à MAPA não apresentou impacto prognóstico independente na análise múltipla, por outro lado, o descenso da FC ao sono foi um bom marcador de mortalidade cardiovascular ... / Introduction: More than half of the deaths in patients with chronic kidney disease (CKD) are attributed to cardiovascular disease. Blood pressure control (BP ) is considered a main strategy in reducing morbidity and mortality in chronic renal population. Ambulatory blood pressure monitoring (ABPM ) has been shown to be higher to office BP in defining prognosis and outcome in all stages of CKD. Some data of ABPM, such as blood pressure variability ( BPV ) and the attenuation of heart rate decrease (HRa) while sleeping were observed as risk factors for overall and cardiovascular mortality in hypertensive population, but no studies on CKD population who evaluated BPV and HRa decrease while sleeping measured by ABPM. The objectives of this study were to evaluate the prognostic impact of the BPV and the decrease of HR while sleeping obtained by ABPM in individuals with chronic kidney disease. Patients and methods : An observational, longitudinal and retrospective study which involved the analysis of 251 ABPM examinations in individuals with CKD at Hospital das Clinicas, Faculty of Medicine of Botucatu followed by a median of 34 months. Results: When comparing patients with fatal outcomes from cardiovascular causes and from all causes, with those who did not present outcomes, there is an age and prevalence of more advanced stages of CKD. Even after adjusting for CKD stage, age and PP in wakefulness, the lowest decrease of HRa while sleeping ( HR : 0.925 , 95% CI : 0.865 to 0.991 , p = 0.026 ) was independent predictor of cardiovascular mortality. The results showed no independent association between BPV, measured by the standard deviation of the pressure with mortality. Conclusion: BPV to ABPM did not show independent prognostic impact in multivariate analysis, however, the decrease of HRa while sleeping was a good marker of cardiovascular mortality in CKD, even after adjustment for misconfusion factors. The short follow-up time and ...
119

Monitorização ambulatorial da pressão arterial : variabilidade da pressão, descenso da frequência cardíaca ao sono e risco de eventos fatais na doença renal crônica /

Marchi, Daniel. January 2014 (has links)
Orientador: Luis Cuadrado Martin / Coorientador: Jorge Roberto da Silva Franco / Banca: José Jayme Galvão de Lima / Banca: João Egídio Romão Junior / Resumo: Introdução: Mais da metade das mortes em portadores de doença renal crônica (DRC) são atribuídas à doença cardiovascular. O controle da pressão arterial (PA) é considerado uma estratégia fundamental na redução da morbidade e mortalidade na população renal crônica. A monitorização ambulatorial da pressão arterial (MAPA) tem se mostrado superior à PA de consultório ao definir prognóstico e desfecho em todos os estádios da DRC. Alguns dados obtidos da MAPA,como a variabilidade da pressão arterial (VPA) e a atenuação do descenso da frequência cardíaca (FC) ao sono, mostraram-se fatores de risco para mortalidade geral e cardiovascular na população hipertensa, porém não há estudos na população com DRC que avaliaram a VPA e o descenso da FC ao sono aferidos pela MAPA. Os objetivos deste estudo foram avaliar o impacto prognóstico da VPA e do descenso da FC ao sono obtidos pela MAPA em renais crônicos. Pacientes e métodos: Estudo longitudinal, observacional e retrospectivo que envolveu a análise de 251 exames de MAPA de indivíduos com DRC realizados no Hospital das Clínicas da Faculdade de Medicina de Botucatu seguidos pela mediana de 34 meses. Resultados: Ao comparar os pacientes que apresentaram desfechos fatais de origem cardiovascular e por todas as causas, com os que não apresentaram desfechos, nota-se idade superior e predominância de estádios mais avançados da DRC. Mesmo após ajuste para estádio da DRC, idade e PP na vigília, o menor descenso da FC ao sono (HR: 0,925, IC 95% : 0,865 a 0,991, p=0,026) mostrou-se preditor independente de mortalidade cardiovascular. Os resultados não mostraram associação independente entre a VPA, avaliada pelo desvio padrão das pressões, com mortalidade. Conclusão: A VPA à MAPA não apresentou impacto prognóstico independente na análise múltipla, por outro lado, o descenso da FC ao sono foi um bom marcador de mortalidade cardiovascular... / Abstract: Introduction: More than half of the deaths in patients with chronic kidney disease (CKD) are attributed to cardiovascular disease. Blood pressure control (BP ) is considered a main strategy in reducing morbidity and mortality in chronic renal population. Ambulatory blood pressure monitoring (ABPM ) has been shown to be higher to office BP in defining prognosis and outcome in all stages of CKD. Some data of ABPM, such as blood pressure variability ( BPV ) and the attenuation of heart rate decrease (HRa) while sleeping were observed as risk factors for overall and cardiovascular mortality in hypertensive population, but no studies on CKD population who evaluated BPV and HRa decrease while sleeping measured by ABPM. The objectives of this study were to evaluate the prognostic impact of the BPV and the decrease of HR while sleeping obtained by ABPM in individuals with chronic kidney disease. Patients and methods : An observational, longitudinal and retrospective study which involved the analysis of 251 ABPM examinations in individuals with CKD at Hospital das Clinicas, Faculty of Medicine of Botucatu followed by a median of 34 months. Results: When comparing patients with fatal outcomes from cardiovascular causes and from all causes, with those who did not present outcomes, there is an age and prevalence of more advanced stages of CKD. Even after adjusting for CKD stage, age and PP in wakefulness, the lowest decrease of HRa while sleeping ( HR : 0.925, 95% CI : 0.865 to 0.991, p = 0.026 ) was independent predictor of cardiovascular mortality. The results showed no independent association between BPV, measured by the standard deviation of the pressure with mortality. Conclusion: BPV to ABPM did not show independent prognostic impact in multivariate analysis, however, the decrease of HRa while sleeping was a good marker of cardiovascular mortality in CKD, even after adjustment for misconfusion factors. The short follow-up time and ... / Mestre
120

Calibre vascular retiniano e a pressão arterial medida por monitoramento ambulatorial da pressão arterial

Pakter, Helena Messinger January 2010 (has links)
É bem conhecido que alterações vasculares iniciam como um processo silencioso e assintomático. A identificação precoce de anormalidades vasculares na retina em pacientes assintomáticos pode permitir a detecção de pacientes em risco de desenvolver DCV. Por prover visualização direta do leito vascular, a retina pode ser estudada não invasivamente mostrando o grau de acometimento da microcirculação. Avanços nas técnicas de fotografia retiniana e de análise digital de imagem tem permitido a mensuração objetiva de alterações vasculares da retina. Com isso, é possível quantificar anormalidades na microvasculatura retiniana, imprescindível para o estudo da fisiopatologia da hipertensão arterial sistêmica, bem como para a avaliação da associação com doença cardiovascular. Um software desenvolvido pela autora desta tese e colaboradores é capaz de medir calibre de arteríolas e vênulas de retinografias digitalizadas. Esse software, nomeado Retinal Analyser System (RAS), foi atualizado e houve a inclusão e testagem de um fator de escala ou calibração, apresentado no Artigo 1 dessa tese. Os métodos de análise de imagens da retina utilizados para medir calibre dos vasos retinianos não determinam exatamente o que está sendo medido. Assim, havia necessidade de investigar se o calibre medido no software RAS corresponde ao lúmen vascular somente ou se inclui a parede vascular. O Artigo 2 dessa tese apresenta a comparação de medidas de calibre de vasos retinianos, em retinografias coloridas com angiografias fluoresceínicas. Nesse artigo concluímos que, como as diferenças encontradas entre os dois métodos foram muito pequenas, o método microdensitométrico mede o lúmen vascular. Os calibres vasculares retinianos avaliados quantitativamente por métodos digitalizados tem mostrado uma associação significativa com incidência e gravidade da hipertensão arterial casual. No entanto, nas últimas décadas, tem sido discutido o valor da medida casual da pressão arterial para fins prognósticos. Em função da variação contínua da pressão arterial, de momento a momento, de acordo com as atividades do indivíduo, novos métodos podem complementar a avaliação através de medidas repetidas da pressão arterial, permitindo a detecção da pressão arterial usual. Tendo em vista essas considerações, o Artigo 3 dessa tese avaliou a associação entre os diferentes parâmetros da pressão arterial, medida pela MAPA, e os calibres vasculares retinianos. A relação entre pressão arterial e calibre arteriolar e venular da retina no momento da obtenção retinografia também foi estudada. Demonstramos que a pressão diastólica média das 24 horas, da vigília e do sono teve associação inversa e significativa com calibre arteriolar e razão arterio-venosa, mas não com calibre venular. A pressão arterial medida na hora da retinografia não mostrou associação com o calibre dos vasos retinianos. Assim concluímos que a associação entre o calibre arteriolar dos vasos retinianos e a pressão arterial não é influenciada pela variação instantânea da pressão arterial e, provavelmente, depende de lesões histológicas da parede arteriolar secundária à hipertensão sustentada. Através da MAPA também é possível avaliarmos a variação temporal da pressão arterial ao longo de um período de 24 horas, e assim estudar o ritmo circadiano e a ritimicidade da pressão arterial. Uma maneira de analisar a ritimicidade da pressão arterial é através do método Cosinor, um método de análise de regressão periódica, baseada na adaptação da função do coseno, para valores da pressão arterial com período de 24 horas. O método Cosinor gera, em cada elemento (indivíduo ou população), os seguintes parâmetros de validação do ritmo circadiano: MESOR (sigla em inglês para média do ritmo ajustada estatísticamente), acrofase e amplitude. O estudo do ritmo circadiano da pressão arterial, avaliado pela da análise de cosinor, e sua associação com os calibres vasculares retinianos, resultou no artigo 4 dessa tese. Nesse artigo, mostramos que o MESOR associa-se significativa e inversamente com calibre arteriolar, com uma magnitude de 0.8 a 1 micron de redução no calibre para um aumento de 10 mmHg do MESOR da pressão arterial. O calibre venular não mostrou associação com o MESOR. Também usamos a análise de Cosinor para população e avaliamos as diferenças nos ritmos da pressão arterial entre as populações do primeiro e dos demais quintis de calibre vascular. Através desta análise observamos que amplitude e acrofase da pressão arterial são estatisticamente diferente entre as populações do primeiro e demais quintis de calibre venoso, mas não arteriolar. Em resumo, enquanto o MESOR está associado ao calibre arteriolar, a amplitude e a acrofase estão associadas ao calibre venular. Concluindo, essa tese mostra, através de seus 4 artigos, a aplicação do software RAS para medida de calibres vasculares retinianos e a associação dessas medidas com pressão arterial, em uma população de pacientes hipertensos. A associação entre o calibre vascular retiniano, a pressão arterial medida 24 horas e o seu ritmo, demonstrada nessa tese, fortalece a hipótese que a avaliação da microvasculatura retiniana pode ser um marcador clínico importante de lesão em órgão. / It is well known that vascular changes begin as a silent and asymptomatic process. Early identification of retinal vascular abnormalities in asymptomatic patients may allow the detection of patients at risk. By providing unique visualization of the vascular bed, the retina can be studied no invasively and show the degree of microcirculation involvement. Advances in techniques of retinal photography and digital image analysis have allowed objective measurement of retinal vascular changes. Thus, it is possible to quantify abnormalities in the retinal microvasculature, essentially to study hypertension pathophysiology, and to assess its association to cardiovascular disease. Software developed by our research group is able to measure the caliber of arterioles and venules of digitized fundus. This software, named Retinal Analyzer System (RAS), has been updated by including and testing a scale factor, presented in Article 1 of this thesis. The current methods of image analysis used to measure the caliber of retinal vessels do not determine exactly what is being measured. Thus there was need to investigate whether the caliber measured in RAS software corresponds to the vascular lumen only or whether it includes the vascular wall. Article 2 of this thesis presents a comparison of the measurements of retinal vessels calibers in color fundus photography to those in fluorescein angiography. In this article we show that the differences found between the two methods were very small, and concluded that the microdensitometry method measures mainly the vascular lumen. The retinal vascular calibers measured quantitatively by microdensitometric methods have shown a significant association with incidence and severity of hypertension. However, studies evaluating these associations are based on casual blood pressure and, in recent decades, it has been discussed the value of casual blood pressure measurement. In light of continuous variation in blood pressure from moment to moment, according to the individual's activities, new methods can complement the assessments through repeated measurements of blood pressure, allowing the detection of usual blood pressure. Given these considerations, Article 3 of this thesis examined the association between different parameters of the blood pressure measured by ABPM, and retinal vascular caliber. The relationship between blood pressure at the time of retinography acquisition and retinal arteriolar and venular caliber was also studied. We show that the mean 24 hours, daytime and night time diastolic blood pressure were significantly and inversely associated with arteriolar caliber and arteriovenous ratio, but not with venular caliber. The pressure measured at the time of acquisition of the fundus showed no association with the caliber of retinal vessels, thus the association between arteriolar retinal vessels caliber and blood pressure is not influenced by instantaneous variation of blood pressure and probably depends of histological damage of arteriolar wall secondary to sustained hypertension. Using ABPM is also possible to evaluate the temporal variation of blood pressure over a period of 24 hours, and then study the circadian rhythm of blood pressure. One way to analyze the blood pressure rhythm is using the Cosinor method, a method of periodic regression analysis, based on the adaptation of the cosine function, for values of blood pressure with 24-hour period. The method Cosinor generates the following validation parameters of the circadian rhythm: MESOR (acronym for "Midline Estimated Statistic Of Rhythm"), acrophase and amplitude. The study of circadian rhythm of blood pressure, as assessed by analysis COSINOR and its association with retinal vascular caliber, resulted in Article 4 of this thesis. In this paper we show that MESOR is associated significantly and inversely with arteriolar caliber, with a magnitude of 0.8 to 1 micron reduction to an increase of 10 mmHg of blood pressure MESOR. The venular caliber was not associated with MESOR. We also use the Cosinor analysis to study differences in the rhythms of blood pressure among populations in the first quintile and the rest quintiles of vascular caliber. Through this analysis we found that amplitude and acrophase of blood pressure were statistically different between the populations of the first and the other quintiles of venous caliber, but not arterioles. In conclusion, this thesis shows, through its four articles, the application of RAS software to measure retinal vascular caliber and the association of these measurements with blood pressure in a population of hypertensive patients. The association between retinal vascular calibers, blood pressure measured 24 hours and rhythm, as demonstrated in this thesis, strengthens the hypothesis that assessment of the retinal microvasculature may be an important clinical marker of organ damage.

Page generated in 0.1112 seconds