• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 255
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 255
  • 156
  • 73
  • 40
  • 30
  • 29
  • 29
  • 29
  • 28
  • 26
  • 26
  • 22
  • 22
  • 20
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Projeto e desenvolvimento de dispositivos de usinagem para cirurgia de recapeamento do quadril / Design and processing devices development for surgery hip resurfacing

Botega, Renan 24 August 2015 (has links)
As progressivas inovações tecnológicas, na área de projeto mecânico, contribuem para a adoção de novos procedimentos cirúrgicos relacionados à ortopedia. Este trabalho trata do projeto, desenvolvimento e fabricação de dispositivos de usinagem e instrumentais cirúrgicos para aplicação em cirurgias de recapeamento da cabeça femoral em humanos e animais, buscando aperfeiçoar tal procedimento no que diz respeito a tecnologias voltadas à modelagem óssea e furação centralizada com a cabeça femoral. Nesse contexto, a relação tempo x precisão foi muito bem explorada, de forma a auxiliar com eficiência os cirurgiões e os pacientes que necessitam dessa cirurgia reduzindo a interferência da habilidade do cirurgião no resultado final da cirurgia. A fresa multilaminar sequencial, criada para usinar a cabeça femoral conforme geometria interna da prótese de recapeamento de quadril é uma importante ferramenta para redução do tempo de cirurgia, uma vez que é necessária a troca de ferramentas durante os procedimentos cirúrgicos como mostrado nesta tese. O instrumental cirúrgico, responsável para o funcionamento correto desses dispositivos de usinagem, é um guia de furação personalizado capaz de alinhar a broca e a fresa durante a modelagem da cabeça femoral, de acordo com o ângulo do colo femoral de cada paciente. Assim, este trabalho trata da concepção, desenvolvimento e fabricação de protótipos de um dispositivo de usinagem e instrumentais cirúrgicos que promovam a usinagem centralizada seguindo o ângulo do colo femoral, redução do tempo de cirurgia e da aplicação cirúrgica com prótese de recapeamento artroplastia de recapeamento canina. Os produtos desenvolvidos nesse trabalho serão nomeados como \"fresa multilaminar sequencial\", \"máscara para furação centralizada\" e \"prótese e instrumentais cirúrgicos para cães\", para a artroplastia de recapeamento de quadril. Com os desenvolvimentos, é esperada uma redução no tempo da cirurgia, bem como um aumento na segurança, possibilitando maior sucesso nesses procedimentos em humanos, bem como trás nova tecnologia para a medicina veterinária. / Progressive technological innovations in the area of mechanical design, contribute to the adoption of new surgical procedures related to orthopedics. This work addresses the design development and manufacture of machining devices and surgical instruments to be used in resurfacing surgeries of the femoral head in humans and animals, seeking to improve this procedure in regards to a new technology related to bone structure for machining and drilling aligned with the femoral head. In this context, the relation time c accuracy was very well explored, in order to assist with efficiency surgeons and patients requiring surgery that reduces the interference on the skill of the surgeon on the surgery outcome. The simultaneous development of the multilaminar-mill, designed to machine the femoral head matching the internal geometry of the resurfacing prosthesis is an important tool for reducing the surgery time, as the tool changes during surgery as shown this thesis. The surgical instrument responsible for the proper operation of these machining devices is a customized guide drill mark capable of aligning the drill and the mill during drilling and milling of the femoral head, according to the angle of the femoral neck of each patient. This work deals with the design, development and manufacturing of a machining device prototype and surgical instruments to promote the centralized machining following the angle of the femur neck the reduction of surgery time and the innovate arthroplasty surgery in humans animals. The products developed in this work are named as \"sequential multilaminar mill\", \"drilling centering mask\" and \"prosthesis and instrumental for dogs\", for hip resurfacing arthroplasty. With the developments, it is expected to reduce the surgical time, as well increasing safety, allowing greater success in these procedures.
32

Projeto e desenvolvimento de dispositivos de usinagem para cirurgia de recapeamento do quadril / Design and processing devices development for surgery hip resurfacing

Renan Botega 24 August 2015 (has links)
As progressivas inovações tecnológicas, na área de projeto mecânico, contribuem para a adoção de novos procedimentos cirúrgicos relacionados à ortopedia. Este trabalho trata do projeto, desenvolvimento e fabricação de dispositivos de usinagem e instrumentais cirúrgicos para aplicação em cirurgias de recapeamento da cabeça femoral em humanos e animais, buscando aperfeiçoar tal procedimento no que diz respeito a tecnologias voltadas à modelagem óssea e furação centralizada com a cabeça femoral. Nesse contexto, a relação tempo x precisão foi muito bem explorada, de forma a auxiliar com eficiência os cirurgiões e os pacientes que necessitam dessa cirurgia reduzindo a interferência da habilidade do cirurgião no resultado final da cirurgia. A fresa multilaminar sequencial, criada para usinar a cabeça femoral conforme geometria interna da prótese de recapeamento de quadril é uma importante ferramenta para redução do tempo de cirurgia, uma vez que é necessária a troca de ferramentas durante os procedimentos cirúrgicos como mostrado nesta tese. O instrumental cirúrgico, responsável para o funcionamento correto desses dispositivos de usinagem, é um guia de furação personalizado capaz de alinhar a broca e a fresa durante a modelagem da cabeça femoral, de acordo com o ângulo do colo femoral de cada paciente. Assim, este trabalho trata da concepção, desenvolvimento e fabricação de protótipos de um dispositivo de usinagem e instrumentais cirúrgicos que promovam a usinagem centralizada seguindo o ângulo do colo femoral, redução do tempo de cirurgia e da aplicação cirúrgica com prótese de recapeamento artroplastia de recapeamento canina. Os produtos desenvolvidos nesse trabalho serão nomeados como \"fresa multilaminar sequencial\", \"máscara para furação centralizada\" e \"prótese e instrumentais cirúrgicos para cães\", para a artroplastia de recapeamento de quadril. Com os desenvolvimentos, é esperada uma redução no tempo da cirurgia, bem como um aumento na segurança, possibilitando maior sucesso nesses procedimentos em humanos, bem como trás nova tecnologia para a medicina veterinária. / Progressive technological innovations in the area of mechanical design, contribute to the adoption of new surgical procedures related to orthopedics. This work addresses the design development and manufacture of machining devices and surgical instruments to be used in resurfacing surgeries of the femoral head in humans and animals, seeking to improve this procedure in regards to a new technology related to bone structure for machining and drilling aligned with the femoral head. In this context, the relation time c accuracy was very well explored, in order to assist with efficiency surgeons and patients requiring surgery that reduces the interference on the skill of the surgeon on the surgery outcome. The simultaneous development of the multilaminar-mill, designed to machine the femoral head matching the internal geometry of the resurfacing prosthesis is an important tool for reducing the surgery time, as the tool changes during surgery as shown this thesis. The surgical instrument responsible for the proper operation of these machining devices is a customized guide drill mark capable of aligning the drill and the mill during drilling and milling of the femoral head, according to the angle of the femoral neck of each patient. This work deals with the design, development and manufacturing of a machining device prototype and surgical instruments to promote the centralized machining following the angle of the femur neck the reduction of surgery time and the innovate arthroplasty surgery in humans animals. The products developed in this work are named as \"sequential multilaminar mill\", \"drilling centering mask\" and \"prosthesis and instrumental for dogs\", for hip resurfacing arthroplasty. With the developments, it is expected to reduce the surgical time, as well increasing safety, allowing greater success in these procedures.
33

Estudo comparativo da osteointegração da haste femoral não cimentada nas artroplastias totais do quadril em pacientes com má qualidade óssea e com boa qualidade óssea / Comparative study of osseointegration of uncemented femoral stem in total hip replacements in patients with poor bone quality and good bone quality

Leonhardt, Marcos de Camargo 29 April 2013 (has links)
Introdução: Com o desenvolvimento das artroplastias não cimentadas, estudos vêm sendo realizados com o objetivo de se determinar se as hastes femorais não cimentadas poderiam ser utilizadas em qualquer paciente,ou estaria reservada apenas para aqueles que possuem boa qualidade óssea. Um estudo comparativo é realizado para avaliar a osteointegração de hastes femorais não cimentadas nas artroplastias totais de quadril em pacientes que apresentam má qualidade óssea, comparando com pacientes que apresentam boa qualidade óssea. Materiais e métodos: Este estudo inclui 196 pacientes submetidos à artroplastia total do quadril primária não cimentada por diagnóstico de osteoartrite primária e secundária com no mínimo de 12 meses de seguimento, divididos em dois grupos: um contendo pacientes com boa qualidade óssea (DorrA); e outro com pacientes com má qualidade óssea (Dorr B e C). Foi avaliada a osteointegração através da análise radiográfica seguindo os critérios estabelecidos por Engh, além de avaliar o resultado clínico e funcional através do questionário de WOMAC. Foram também avaliadas as complicações decorrentes do processo cirúrgico em ambos os grupos. Resultados:Há diferença na frequência do gênero no grupo Má Qualidade Óssea (MQO) (p=0,009) com predomínio de mulheres e diferença no diagnóstico inicial,havendo um número maior de casos de patologias reumatológicas e sequelas de displasia no grupo MQO (p=0,0002). Não observamos diferença quanto a idade, lado operado e tempo de seguimento entre os dois grupos. Não observamos diferença entre os grupos quando avaliado o escore clínico, a osteointegração ou a necessidade de revisão. Observamos um maior risco de fratura intraoperatória do fêmur proximal no grupo MQO (p=0.03) comparando-se com o grupo Boa Qualidade Óssea (BQO). Conclusão: Concluímos que as hastes femorais não cimentadas osteointegram igualmente, independentemente da qualidade óssea do paciente e que fraturas intraoperatórias ocorrem mais quando realizadas hastes femorais não cimentadas em pacientes com má da qualidade óssea / Introduction: With the development of the non cemented total hip replacement, many studies were carried out to determinate if uncemented femoral stem can be used in every patient, or if this kind of implants are reserved for those patients with good bone quality. A comparative study was carried out to evaluate the osseointegration of uncemented femoral stem in total hip replacements in patients that have poor bone quality, comparing with patients that have good bone quality. Methods: The study included 196 cases of primary uncemented total hip arthroplasties due to a diagnosis of primary or secondary osteoarthritis, with a minimum of 12 months of follow-up, divided in two groups: one with patients that have good bone quality (Type A Dorr), and another with patients that have poor bone quality (Types B and C Dorr). Osseointegration was evaluated by X ray analysis, following the Engh\'s criteria. Clinical and functional results were also evaluated by the application of the WOMAC questionnaire, and complication in both groups were reported. Results: Regarding our patient\' gender, we observed a significant difference between the two groups: there was more women in the group of Poor Bone Quality (PBQ) (p=0,009). We also observed a significant difference in the initial diagnosis of the patients: there was more osteoarthritis secondary to rheumatic pathologies and hip dysplasia in the PBQ group (p=0,0002). There was no difference when observed the mean age, operation\' side and mean time of follow-up between the two groups. We also did not observed differences between the groups when evaluated the clinical scores, the osseointegration of the femoral stem and the need of revision of the arthroplasty by any reason. But, in the PBQ, we observed a higher risk of intra operative fracture in the proximal femur compared with the group Good Bone Quality (GBQ) (p=0,03). Conclusion: We concluded that the uncemented femoral stem has an equal rate of osseointegration, despite the bone quality and that there is a higher risk of intra operative fracture when implanted an uncemented femoral stem in bone with poor quality
34

Estudo comparativo da osteointegração da haste femoral não cimentada nas artroplastias totais do quadril em pacientes com má qualidade óssea e com boa qualidade óssea / Comparative study of osseointegration of uncemented femoral stem in total hip replacements in patients with poor bone quality and good bone quality

Marcos de Camargo Leonhardt 29 April 2013 (has links)
Introdução: Com o desenvolvimento das artroplastias não cimentadas, estudos vêm sendo realizados com o objetivo de se determinar se as hastes femorais não cimentadas poderiam ser utilizadas em qualquer paciente,ou estaria reservada apenas para aqueles que possuem boa qualidade óssea. Um estudo comparativo é realizado para avaliar a osteointegração de hastes femorais não cimentadas nas artroplastias totais de quadril em pacientes que apresentam má qualidade óssea, comparando com pacientes que apresentam boa qualidade óssea. Materiais e métodos: Este estudo inclui 196 pacientes submetidos à artroplastia total do quadril primária não cimentada por diagnóstico de osteoartrite primária e secundária com no mínimo de 12 meses de seguimento, divididos em dois grupos: um contendo pacientes com boa qualidade óssea (DorrA); e outro com pacientes com má qualidade óssea (Dorr B e C). Foi avaliada a osteointegração através da análise radiográfica seguindo os critérios estabelecidos por Engh, além de avaliar o resultado clínico e funcional através do questionário de WOMAC. Foram também avaliadas as complicações decorrentes do processo cirúrgico em ambos os grupos. Resultados:Há diferença na frequência do gênero no grupo Má Qualidade Óssea (MQO) (p=0,009) com predomínio de mulheres e diferença no diagnóstico inicial,havendo um número maior de casos de patologias reumatológicas e sequelas de displasia no grupo MQO (p=0,0002). Não observamos diferença quanto a idade, lado operado e tempo de seguimento entre os dois grupos. Não observamos diferença entre os grupos quando avaliado o escore clínico, a osteointegração ou a necessidade de revisão. Observamos um maior risco de fratura intraoperatória do fêmur proximal no grupo MQO (p=0.03) comparando-se com o grupo Boa Qualidade Óssea (BQO). Conclusão: Concluímos que as hastes femorais não cimentadas osteointegram igualmente, independentemente da qualidade óssea do paciente e que fraturas intraoperatórias ocorrem mais quando realizadas hastes femorais não cimentadas em pacientes com má da qualidade óssea / Introduction: With the development of the non cemented total hip replacement, many studies were carried out to determinate if uncemented femoral stem can be used in every patient, or if this kind of implants are reserved for those patients with good bone quality. A comparative study was carried out to evaluate the osseointegration of uncemented femoral stem in total hip replacements in patients that have poor bone quality, comparing with patients that have good bone quality. Methods: The study included 196 cases of primary uncemented total hip arthroplasties due to a diagnosis of primary or secondary osteoarthritis, with a minimum of 12 months of follow-up, divided in two groups: one with patients that have good bone quality (Type A Dorr), and another with patients that have poor bone quality (Types B and C Dorr). Osseointegration was evaluated by X ray analysis, following the Engh\'s criteria. Clinical and functional results were also evaluated by the application of the WOMAC questionnaire, and complication in both groups were reported. Results: Regarding our patient\' gender, we observed a significant difference between the two groups: there was more women in the group of Poor Bone Quality (PBQ) (p=0,009). We also observed a significant difference in the initial diagnosis of the patients: there was more osteoarthritis secondary to rheumatic pathologies and hip dysplasia in the PBQ group (p=0,0002). There was no difference when observed the mean age, operation\' side and mean time of follow-up between the two groups. We also did not observed differences between the groups when evaluated the clinical scores, the osseointegration of the femoral stem and the need of revision of the arthroplasty by any reason. But, in the PBQ, we observed a higher risk of intra operative fracture in the proximal femur compared with the group Good Bone Quality (GBQ) (p=0,03). Conclusion: We concluded that the uncemented femoral stem has an equal rate of osseointegration, despite the bone quality and that there is a higher risk of intra operative fracture when implanted an uncemented femoral stem in bone with poor quality
35

Análise da qualidade de vida de pacientes osteoartrósicos submetidos à artroplastia total do quadril

Loures, Elmano de Araújo 20 October 2011 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-07-14T11:51:08Z No. of bitstreams: 1 elmanodearaujoloures.pdf: 9149491 bytes, checksum: 08630dfeb5037d2bfef775000aee4585 (MD5) / Approved for entry into archive by Diamantino Mayra (mayra.diamantino@ufjf.edu.br) on 2016-07-19T14:30:09Z (GMT) No. of bitstreams: 1 elmanodearaujoloures.pdf: 9149491 bytes, checksum: 08630dfeb5037d2bfef775000aee4585 (MD5) / Made available in DSpace on 2016-07-19T14:30:09Z (GMT). No. of bitstreams: 1 elmanodearaujoloures.pdf: 9149491 bytes, checksum: 08630dfeb5037d2bfef775000aee4585 (MD5) Previous issue date: 2011-10-20 / A artroplastia total do quadril possui uma das melhores relações custo-benefício dentre todas as intervenções realizadas no aparelho locomotor. Grande parte das publicações aborda somente os aspectos técnicos e o desempenho dos implantes e negligencia a repercussão sobre a qualidade de vida e as co-morbidades, tornando a medida correta dos benefícios do tratamento imprecisa. Atualmente, os parâmetros de medição da qualidade de vida associados às escalas funcionais tornaram-se imperativos para uma análise acurada de resultados e fatores influentes. O objetivo principal do estudo foi avaliar a qualidade de vida relacionada à saúde em pacientes afetados por osteoartrose do quadril e tratados por artroplastia total do quadril. Estudou-se prospectivamente uma coorte de 38 pacientes operados em hospital universitário de referência regional acompanhados durante, no mínimo, seis meses até atingirem reabilitação satisfatória. Secundáriamente, avaliou-se o desempenho de curto prazo do componente acetabular MD4® implantado em 35 indivíduos. Os dados foram obtidos por meio da aplicação de quatro instrumentos: 1) questionário para a caracterização sóciodemográfica e clínica da amostra; 2) escala de avaliação funcional do quadril – Harris Hip Score (HHS); 3) instrumento genérico de avaliação da qualidade de vida relacionada à saúde The Medical Outcomes Study 36-item Short-Form Health Survey (SF-36) e 4) questionário de avaliação da satisfação individual com o procedimento. Os resultados dos testes pré e pós-operatórios foram submetidos à análise estatística descritiva e comparados com a literatura. Os resultados pré e pósoperatórios do SF-36 foram capacidade funcional: 13,4-53,7; limitação por aspectos físicos: 9,21-48,0; dor: 23,1-62,6; estado geral de saúde: 54,2-71,3; vitalidade: 40,3- 69,9; aspectos sociais: 40,8-74,3; limitação por aspectos emocionais: 23,7-64,9; saúde mental: 52,6-80,4. O Harris Hip Score variou de 36,1 a 92,1, em média. Todos os resultados foram estatisticamente significantes (p < 0,001). A combinação de duas escalas mostrou-se valiosa na identificação de vieses e conferiu maior confiabilidade na compreensão das diversas variáveis. O estudo demonstra uma significativa melhora na qualidade de vida relacionada à saúde em pacientes afetados por osteoartrose de diferentes etiologias submetidos à artroplastia total do quadril. A avaliação da qualidade de vida não substitui a avaliação clínica provida por instrumentos específicos e pela experiência do cirurgião, mas pode adicionar dados importantes ao valorizar o conjunto de expectativas do paciente perante um tratamento médico e ser considerada um instrumento eficiente na análise de resultados da artroplastia total do quadril. Adicionalmente, o componente acetabular avaliado mostrou estabilidade e indícios de osteointegração em todos os casos, o que pode ser considerado indicativo de bom desempenho a médio prazo do implante. / Total hip replacement is one of the most cost-effective procedures upon the locomotor system. Most of the publications covers only the technical aspects and the performance of implants and neglects the impact on the quality of life and comorbidities, making the correct measurement of a treatment benefits imprecise. Nowadays, the measurement of health-related quality of life associated with functional scales has become imperative for more accurate analysis of results and influencing factors. To assess the health – related quality of life in patients with osteoarthritis and undergoing total hip arthroplasty was the main goal in this study. A cohort of 38 patients from a regional referral teaching hospital was prospectively followed up for at least six months until they have achieved satisfactory rehabilitation. Secondarily, the short-term performance of the MD-4® acetabular component implanted in 35 individuals was evaluated. Data were obtained through the application of four instruments: 1) questionnaire for socio-demographic and clinical characteristics of the sample; 2) functional scale of the hip - Harris Hip Score (HHS); 3) generic instrument for assessing health-related quality of life The Medical Outcomes Study 36-Item Short-Form Health Survey (SF-36) and 4) questionnaire assessing individual satisfaction with the procedure. The results pre and postoperatively were analyzed using descriptive statistics and compared with the literature. The SF-36 results pre and post-operative were functional capacity: 13.4 to 53.7, limited by physical aspects: 9.21 to 48.0; pain: 23.1 to 62.6, general health: 54.2 to 71.3; vitality: 40.3 to 69.9; social aspects: from 40.8 to 74.3, limited by emotional aspects: from 23.7 to 64.9; mental health: 52.6 - 80.4. The Harris Hip Score ranged from 36.1 to 92.1 on average. All results were statistically significant (p < 0.001). The combination of two scales showed up to be valuable in bias identification and gave more reliability on the variables understanding. The study reports a significant improvement in health-related quality of life in patients affected by osteoarthritis of many etiologies that underwent total hip replacement. Healthrelated quality of life assessment does not replace clinical evaluation provided by specific instruments and the physician’s experience but can add important data and also can be considered an efficient tool in analyzing outcomes of total hip replacement due to the weight it gives to the patient’s expectations regarding a medical treatment.Additionally , the study showed up evidence of osteointegration and stability of the acetabular cup in all cases, which would be a predictor factor for mid-term survivorship of this acetabular component.
36

An?lise estereogr?fica de implantes de quadril recobertos por plasma spray

Trevizan, Jorge Dal Pozzo 18 August 2006 (has links)
Made available in DSpace on 2015-04-14T13:58:29Z (GMT). No. of bitstreams: 1 385276.pdf: 5282314 bytes, checksum: 856ef46745d6c074bb89e557d32ed4a8 (MD5) Previous issue date: 2006-08-18 / Este trabalho visa avaliar a cobertura parcial do revestimento poroso plasma spray (PS) utilizado em implantes de quadril. Foram testados diversos implantes comerciais, novos e usados, nacionais e importados dos EUA e Portugal, considerados como padr?o ouro. Os resultados, dos implantes nacionais, foram analisados antes e, sugerido um jateamento de areia, anterior ? deposi??o, objetivando aumentar a ades?o do revestimento ao metal base. Novos testes foram realizados para comprovar a efici?ncia da otimiza??o do processo, na ader?ncia da camada de PS. As orienta??es foram determinadas pelas normas ASTM F 1854-01 e os testes de tra??o e an?lise qu?mica, segundo as normas ASTM E 3, E 883, C 633-01, ISO 468, ISO 5832. As avalia??es foram feitas utilizando microscopia ?ptica (MO), microsc?pio eletr?nico de varredura (SEM), espectroscopia de raio X por energia dispersa (EDS) e ensaios de tra??o, com m?quina universal de ensaios. Comprovou-se que a ades?o ao novo implante obteve um acr?scimo superior a 100%, que a camada de PS diminuiu, em aproximadamente 21%, e o volume vazio diminuiu pr?ximo de 16%. Tamb?m foi verificado a osteointegra??o (osso x implante), ap?s noventa dias implantado, e constatado que ela realmente ocorre e ? confi?vel.
37

Avaliação isocinética da musculatura do quadril: revisão sistemática da literatura / Isokinetic evaluation of the hip muscles: a systematic review of the literature

Zapparoli, Fabricio Yuri 14 December 2015 (has links)
A dinamometria isocinética é um método seguro e fidedigno de avaliação da força, trabalho e potência dos grupos musculares e representa o padrão ouro na avaliação em cadeia cinética aberta. Com os avanços tecnológicos, a avaliação isocinética tornou-se uma ferramenta muito utilizada para avaliação do desempenho muscular tanto em estudos biomecânicos como clínicos. O objetivo deste estudo foi realizar revisão sistemática da literatura sobre avaliação isocinética do quadril, com ênfase nos parâmetros metodológicos associados e melhor reprodutibilidade, especificamente: posicionamento do paciente, do eixo do dinamômetro e do braço de alavanca no momento do exame; velocidade angular e tipo de contração. Foi realizada uma pesquisa bibliográfica sistematizada nas bases de dados eletrônicas Cochrane, LILACS, PEDro, PubMed e SciELO. Os critérios de inclusão foram: artigos que avaliaram a força da musculatura do quadril com o dinamômetro isocinético e que continham análise de reprodutibilidade ICC ou PCC dos testes. Foram encontrados 148 artigos selecionados nas bases de dados eletrônicas, deste total foram selecionados 20 estudos que avaliaram isocineticamente a musculatura do quadril, após a pré-seleção dos artigos, os mesmos foram subdivididos em 3 grupos de acordo com o movimento realizado pelo quadril: Grupo 1 treze artigos avaliaram o movimento de flexão e extensão; Grupo 2 nove artigos avaliaram abdução e adução; Grupo 3 seis artigos avaliaram rotação interna e externa, um total de 1137 indivíduos foram submetidos à avaliação isocinética do quadril. Em cada Grupo selecionaram-se os artigos que obtiveram melhor resultado de reprodutibilidade, cujos parâmetros metodológicos foram avaliados. Conclusão: Para obter melhor reprodutibilidade da avaliação isocinética da musculatura flexora e extensora do quadril, o indivíduo deve ser posicionado em decúbito dorsal com o eixo do dinamômetro alinhado no trocânter maior do fêmur. A fixação do braço de alavanca posicionada na região mais distal possível da coxa. A velocidade angular utilizada para análise de pico de torque e trabalho muscular 60°/s e para avaliação da potência muscular 180°/s e as contrações analisadas concêntricas e excêntricas. Na avaliação isocinética da musculatura abdutora e adutora do quadril, o indivíduo deve ser posicionado em decúbito lateral com as costas voltada para o dinamômetro, o eixo do dinamômetro posicionado na intersecção de duas linhas retas, sendo a primeira linha a partir da EIPS até o joelho e a segunda linha medial ao trocânter maior do fêmur em direção à linha média do corpo. A fixação do braço de alavanca posicionada na região distal da coxa. A velocidade angular utilizada para análise de pico de torque e trabalho muscular 30°/s e para avaliação de potência muscular 210°/s. As contrações analisadas foram concêntricas e excêntricas. Na avaliação isocinética dos rotadores internos e externos, o indivíduo testado posicionou-se sentado com eixo do dinamômetro alinhado com a linha articular do joelho, com a fixação do braço de alavanca na região distal da tíbia. A velocidade angular mais utilizada para análise de pico de torque e trabalho muscular foi de 30°/s e para avaliação da potência muscular foi 210°/s, as contrações analisadas também foram concêntricas e excêntricas. / Isokinetic dynamometry is a safe and reliable method for assessing the force, work and power of muscle groups and is the \"gold standard\" in the evaluation of muscle strength in the open kinetic chain. With technological advances, isokinetic evaluation has become a widely used tool to evaluate muscle performance in biomechanical as well as in clinical studies. The objective of this study was to systematically review the literature on isokinetic evaluation of the hip, with emphasis on methodological parameters associated to better reproducibility, specifically: patient positioning, dynamometer axis and lever arm during the evaluation; angular speed and type of contraction. A literature search was carried out systematically in electronic databases Cochrane, LILACS, PEDro, PubMed and SciELO. The inclusion criteria were papers on the evaluation of the hip muscles strength with an isokinetic dynamometer and papers that analyzed the ICC or PCC reproducibility test. 148 papers were found in electronic databases and of this total were selected 20 studies that evaluated isokinetically the muscles of the hip, after pre-selection, they were divided into 3 groups according to the movement performed by the hip: Group 1 - thirteen papers evaluated the flexion and extension; Group 2 - nine papers evaluated abduction and adduction; Group 3 - six papers evaluated internal and external rotation, a total of 1137 subjects underwent isokinetic evaluation of the hip. In each Group were selected items that obtained better results reproducibility, whose methodological parameters were evaluated. In conclusion: in order to obtain better reproducibility of isokinetic evaluation of the flexor and extensor muscles of the hip: the individual must be positioned in the supine position and the dynamometer axis must be aligned in the greater trochanter of the femur. The positioning of the lever arm must be in the most distal region of the thigh possible. The angular speed used to analyze torque peak and muscle work was 60°/s, and to evaluate the muscle power was 180°/s, and contractions analyzed concentric and eccentric. In isokinetic evaluation of the abductor and adductor muscles: the individual must be positioned in the side-lying position with your back toward the dynamometer and the dynamometer axis must be aligned with the intersection of two straight lines, with the 1st line from the posterior-superior iliac spine to the knee and the 2nd line medial to the greater trochanter of the femur toward the midline of the body. The positioning of the level arm must be in the most distal region of the thigh. The speed used to analyze torque peak and muscle work was 30°/s, and to evaluate the muscle power it was 210°/s, with concentric and eccentric contractions being analyzed. In isokinetic evaluation of internal and external rotators: the individual must be positioned in the sitting position and the dynamometer axis must be aligned with the line knee joint. The positioning of the level arm must be in the distal region of the tibia. The speed used to analyze torque peak and muscle work was 30°/s, and to evaluate the muscle power it was 210°/s, with concentric and eccentric contractions being analyzed.
38

Posicionamento do componente acetabular na artroplastia total do quadril com e sem o auxílio de um sistema de navegação computadorizado: estudo comparativo prospectivo randomizado / Acetabular component positioning in total hip arthroplasty with and without a computer-assisted system: a prospective, randomised and controlled study

Gurgel, Henrique Melo de Campos 06 July 2011 (has links)
Em um estudo prospectivo e randomizado sobre o posicionamento do componente acetabular na artroplastia total do quadril, 20 quadris foram operados com o auxílio da navegação livre de métodos de imagem e 20 quadris foram operados através do método convencional. Todas as cirurgias foram realizadas pelo mesmo cirurgião com o paciente em decúbito lateral. A avaliação do posicionamento foi feita através da medição tomográfica pós-operatória dos ângulos de anteversão e inclinação cirúrgicos e análise da zona de segurança. Os resultados obtidos foram similares em todas as comparações: anteversão média de 17,4o no grupo navegado e 14,5o no grupo convencional (p=0,215), inclinação média de 41,7o no grupo navegado e 42,2o no grupo convencional (p=0,633), desvio médio do objetivo da anteversão (15o) de 5,5o no grupo navegado e 6,6o no grupo convencional (p=0,429), desvio médio do objetivo da inclinação (40o) de 3o no grupo navegado e 3,2o no grupo convencional (p=0,783) e localização dentro da zona de segurança de 90% no grupo navegado e 80% no grupo convencional (p=0,661). A avaliação tomográfica pós-operatória do posicionamento acetabular na artroplastia total de quadril realizada com o paciente em decúbito lateral foi semelhante ao se comparar a técnica navegada com a técnica convencional / In a prospective and randomised study of the acetabular component position in total hip arthroplasty, 20 hips were operated using imageless navigation and 20 hips were operated using the conventional method. The same surgeon performed all the operations with the patient in the lateral position. The correct position of the acetabular component was evaluated with computed tomography performed after the surgeries, measuring the operative anteversion angle and the operative inclination angle and determining the cases inside the safe zone. The results were similar in all the analyses: a mean anteversion of 17.4o in the navigated group and 14.5o in the conventional group (p=0.215), a mean inclination of 41.7o in the navigated group and 42.2o in the conventional group (p=0.633), a mean deviation from the desired anteversion (15o) of 5.5o in the navigated group and 6.6o in the conventional group (p=0.429), a mean deviation from the desired inclination (40o) of 3o in the navigated group and 3.2o in the conventional group (p=0.783), and location inside the safe zone of 90% in the navigated group and 80% in the conventional group (p=0.661). The acetabular component positions tomography analyses in total hip arthroplasty, performed with the patient in the lateral position, were similar whether using imageless navigation or performing it conventionally
39

Modelo Experimental da Artros copia do quadril cadÃveres de recÃm-nascidos submetidos do Extresse Axial / Experimental model of hip arthroscopy in newborn cadavers submitted to the axial stress

Ronaldo Silva de Oliveira 31 August 2001 (has links)
CoordenaÃÃo de AperfeiÃoamento de NÃvel Superior / O desenvolvimento do artroscÃpio possibilitou ao cirurgiÃo ortopÃdico o acesso a diversas articulaÃÃes. O quadril, que apresenta complexa anatomia e topografia, permaneceu por muito tempo como uma barreira para os artroscopistas. Com os avanÃos ocorridos ao longo da Ãltima dÃcada, as indicaÃÃes vÃm crescendo a cada ano. Isto fez da artroscopia do quadril uma valiosa tÃcnica que preencheu uma lacuna no esclarecimento diagnÃstico, freqÃentemente pouco elucidativos mesmo com utilizaÃÃo de modernos mÃtodos; possibilitando o tratamento de um nÃmero cada vez maior de afecÃÃes desta articulaÃÃo. Em adultos o mÃtodo à ainda pouco utilizado e em crianÃas apresenta indicaÃÃes muito restritas. Assim, foi decidido realizar um trabalho que propiciasse o desenvolvimento de um modelo experimental de treinamento do mÃtodo artroscÃpico, e atravÃs deste, observar aspectos histomorfolÃgicos de estruturas intra-articulares submetidas à traÃÃo axial. Utilizando quadris de 20 cadÃveres de recÃm-nascidos foi testada a possibilidade de realizar o procedimento. Seis fetos (A1 a A6), representaram o projeto piloto, servindo para desenvolver o modelo de pesquisa e catorze o estudo principal (B1 a B14), seguindo critÃrios estabelecidos com o projeto piloto. Em todos os fetos realizou-se o procedimento utilizando Ãtica de 2,2 mm de espessura com 30 de angulaÃÃo e em todos aplicada traÃÃo axial que variou de 68 a 88 N. Foram utilizados dois portais: antero-lateral e lateral, e no final feito artrotomia e anÃlise histomorfolÃgica das estruturas: pulvinar, labrum acetabular e ligamento redondo do quadril. Ficou estabelecido com o estudo piloto que o procedimento somente à possÃvel realizar com fetos maiores, pois nos quatro fetos em que o peso era abaixo de 1500 g, o procedimento foi tecnicamente impossÃvel. A traÃÃo Foi necessÃria para uma completa inspeÃÃo da articulaÃÃo. Constatou-se ainda que atravÃs de um sà acesso nÃo foi possÃvel visualizar toda a articulaÃÃo, mas, que a utilizaÃÃo de dois acessos, os portais lateral e antero-lateral, oferecem boa seguranÃa sendo possÃvel reproduzir o mÃtodo artroscÃpico e identificar a maior parte das estruturas anatÃmicas intra-articulares. Concluiu-se que a artroscopia do quadril tem tÃcnica difÃcil, mas factÃvel em cadÃveres de recÃm-nascidos com peso superior a 1700 g e nÃo foram encontradas lesÃes macroscÃpicas ou histolÃgicas sobre as estruturas estudadas em fetos submetidos a uma traÃÃo de atà 88 N. / Surgical access to different joints was made possible due to the development of the arthroscope. On account of its complex anatomy and topography the endoscopic access to the hip joint seemed to be an unattainable goal by many specialists for a long period of time. Last decade progress turned arthroscopic examination indications an ever growing need. The procedure helped to fill out the gap in the diagnostic area of hip joint diseases making possible the treatment of many illnesses affecting the joint. Despite this progress the exam is not widely performed in adult patients. Also, usage in children presents very restricted limitations. This paper was aimed at developing an experimental model of hip arthroscopy and to study the histomorphological damages resulted from its use in structures subjected to traction. Twenty newborn cadavers were used. Six fetuses use used during the pilot project (A1-A6). The remainder fourteen fetuses were used during the main study (B1-B14). Optical system (2.2 mm diameter) and 30o angulation were used. Axial traction was applied to all cases (68-88 N). Antero-lateral and lateral ports were used for surgical access to the hip. Histomorphological studies of pulvinar, labrum acetabulare and hip round ligament were carried out in each case. A pilot study has demonstrated that the application of this technique is not feasible in fetuses weighing less than 1500g. The traction was required to secure a complete inspection of the articulation. Using just one port was not possible to visualize all structures. The simultaneous use of lateral and anterolateral ports provided adequate exposure to all joint structures. It is concluded that hip arthroscopy is not an easy procedure although feasible in newborn cadavers weighing more than 1700 g. No macroscopic or histological lesions were identified in fetuses submitted to traction of up to 88 N
40

Estudo da osteonecrose no processo de usinagem da cabeça do fêmur utilizando um dispositivo mecânico de furação / Study of the osteonecrosis in the process of femur head machining by a mechanical drilling device

Higashi, Rosemeire Rosa 12 September 2014 (has links)
A utilização de implantes cirúrgicos para artroplastia de quadril com prótese de recapeamento da cabeça femoral como substituto ósseo é um procedimento que tem sido realizado em 35% dos casos de Osteoartrose nos EUA. Entretanto, o atrito da broca e o aumento da temperatura durante a usinagem da cabeça femoral são responsáveis pelo possível aquecimento do tecido ósseo, podendo provocar a necrose óssea térmica. Neste sentido, o desenvolvimento de novos ferramentais e metodologias para minimizar os danos térmicos do atrito torna-se importante. Diante disso, o presente estudo teve como objetivo verificar se há a ocorrência de necrose óssea em um procedimento de furação óssea utilizando o dispositivo EQUITRON; Mod.ES 2200, desenvolvido no LTC-EESC-USP. Para tal, utilizamos 4 amostras de costela bovina removidas após a morte do animal, que foram furadas com broca de aço inoxidável (HSS-SKF), de 8 milímetros, sem irrigação externa. As amostras foram furadas com rotações de 100, 1000, 1200 e 2500 RPM, aferidas por tacômetro foto/contato digital da marca MINIPA, MDT-2238, e com avanço controlado de 80 mm/min (dispositivo da marca-EQUITRON; MOD.ES 2200; RPM 2800; Potência 0,30; Torque 1,6 Nm). Foram mensuradas as temperaturas iniciais da broca e da amostra e a final da amostra com termômetro digital, marca-MEDISANA®. Após a furação foram confeccionadas lâminas histológicas (HE) do tecido ósseo, preparadas de acordo com a metodologia apropriada, para posterior qualificação e quantificação da ocorrência de necrose óssea térmica através de imagens captadas por microscopia óptica (Olympus BX 41TF - Made Japan) utilizando-se o programa Motic Images Plus 2.0 para a captura das imagens. Os valores de temperaturas aferidos na amostra após a furação apresentaram relação positiva com a RPM utilizada, isto é, quanto maior a rotação, maior foi a temperatura observada. Apenas a amostra furada a 2500 RPM ultrapassou a temperatura de referencia para a gênese da osteonecrose térmica, que é de 47ºC. As análises histológicas apresentaram uma baixa predominância de células picnóticas e lacunas, sugerindo menor dano tecidual. Os resultados obtidos no presente estudo sugerem que o dispositivo (furadeira) desenvolvido no LTC-EESC-USP para a realização das furações nas amostras ósseas em testes de bancada foi eficiente em minimizar a ocorrência de necrose óssea térmica, até mesmo em condições de temperatura acima do limite fisiológico aceitável. / The utilization of surgical implants for hip arthroplasty with a resurfacing prosthesis of the femoral head as a bone substitute have been conducted in 35% of osteoarthrosis cases in the USA. However, the friction of the drill and the increase in the temperature during the machining of the femoral head can possibly heat the bony tissue and provoke a thermal bone necrosis. The development of new tools and methodologies for minimizing the thermal damage of the friction has become fundamental. The present study analyzes the occurrence of bone necrosis in a procedure of bone drilling that uses an EQUITRON device, Mod. ES 2200, developed at the LTC-EESC-USP. Four samples of bovine ribs removed after the death of the animal were used for the tests. They were drilled by an 8mm stainless-steel drill (HSS-SKF) with no external irrigation, at 100, 1000, 1200 and 2500 RPM calibrated by a MINIPA, MDT-2238 digital photo/contact tachometer and whose 80mm/min. advance (EQUITORN device; MOD.ES 2200; RPM 2800; 0.30 Potency and 1,6Nm torque) was controlled. The initial temperatures of the drill and the sample and the final temperature of the sample were measured by a MEDISANA digital thermometer. After drilling, histological blades (HE) were produced from the bony tissue and prepared according to the adequate methodology for further qualification and quantification of the occurrence of thermal bone necrosis through images captured by optical microscopy (Olympus BX 41TF - made in Japan) and Motic Images Plus 2.0 program. The values of the temperatures measured in the sample after drilling showed a positive relation with the RPM utilized, i.e., the faster the rotation, the higher the temperature. Only the sample drilled at 2500RPM exceeded the reference temperature (47ºC) for the genesis of the thermal osteonecrosis. The histological analyses revealed a low predominance of picnotic cells and gaps, which suggest minor tissue damage. The results show the device (drilling machine) developed at the LTC-EESC-USP for the drilling in the bone samples in workbench tests is efficient to minimize the occurrence of thermal bone necrosis, even at temperatures above the physiological acceptable limit.

Page generated in 0.0394 seconds