• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 361
  • 173
  • 30
  • Tagged with
  • 555
  • 555
  • 354
  • 324
  • 317
  • 315
  • 214
  • 202
  • 95
  • 94
  • 93
  • 79
  • 75
  • 68
  • 62
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Methodology for nuclear magnetic resonance and ion cyclotron resonance mass spectrometry / Méthodologie pour résonance magnétique nucléaire et la résonance cyclotron d'ions par spectrométrie de masse

Sehgal, Akansha 08 October 2014 (has links)
Pendant ma thèse de doctorat, j’ai eu la grande chance de travailler sur le développement de nouvelles méthodes de deux techniques spectroscopiques complétement différentes : la Résonance Magnétique Nucléaire (RMN) et la Spectroscopie de Masse par Résonance Cyclotronique Ionique à Transformée de Fourier (FT-ICR/MS). En tant que méthodologiste, mon but principal a été d’améliorer les méthodes existantes et la théorie. En RMN, l’outil fantastique de la manipulation des spins permet la mise en place des séquences d’impulsions, et en FT-ICR, les rapports masse sur charge (m/z) des ions et des fragments d’ions obtenus par différents chemins de fragmentation peuvent être appliqués à des problèmes en chimie, biochimie et médecine. Le manuscrit de ma thèse de doctorat comporte deux parties. Les sujets abordés étant différents, ce manuscrit a été rédigé pour que chaque chapitre puisse être lu indépendamment. La première partie aborde la RMN dans le chapitre I. Dans ce chapitre, nous avons amélioré une méthode développée précédemment dans l’equipe pour l’étude de l’échange rapide des protons par RMN. Nous avons adapté la méthode à l’étude de l’acide aminé histidine, système en apparence simple mais qui s’est avéré très compliqué à l’étude. La deuxième partie de ma thèse de doctorat aborde la spectroscopie de masse et comprend deux chapitres. Dans le chapitre II, nous avons essayé de faire revivre et de mettre en œuvre une méthode longtemps oubliée ; il s’agit de la méthode d’isolement d’ions par éjection sélective (‘notch ejection’) par spectroscopie de masse FT-ICR. Un autre sujet abordé pendant ma thèse, qui est décrit dans le chapitre III, concerne l’utilisation de trois impulsions rf dans une expérience à deux dimensions (2D) ICR. Notre objectif a été de mieux comprendre la complexité du comportement des ions pendant cette expérience 2D ICR, en particulier pour le cas d’impulsions courtes. / This thesis encompasses methodological developments in both nuclear magnetic resonance and Fourier transform ion cyclotron resonance mass spectrometry. The NMR section explores the effects of scalar relaxation on a coupled nucleus to measure fast exchange rates. In order to quantify these rates accurately, a precise knowledge of the chemical shifts of the labile protons and of the scalar couplings is normally required. We applied the method to histidine where no such information was available a priori, neither about the proton chemical shifts nor about the one-bond scalar coupling constants J(1H15N), since the protons were invisible due to fast exchange. We have measured the exchange rates of the protons of the imidazole ring and of amino protons in histidine by indirect detection via 15N. Not only the exchange rate constants, but also the elusive chemical shifts of the protons and the coupling constants could be determined. For the mass spectrometry section, the ion isolation project was initiated to study the effect of phase change of radiofrequency pulses. Excitation of ions in the ICR cell is a linear process, so that the pulse voltage required for ejecting ions must be inversely proportional to the pulse duration. A continuous sweep pulse propels the ion to a higher radius, whereas a phase reversal causes the ion to come to the centre. This represents the principle of ‘notch ejection’, wherein the ion for which the phase is reversed is retained in the ICR cell, while the remaining ions are ejected. The manuscript also contains a theoretical chapter, wherein the ion trajectories are plotted by solving the Lorentzian equation for the three-pulse scheme used for two-dimensional ICR. Through our simulations we mapped the ion trajectories for different pulse durations and for different phase relations.
92

Modélisation locale en imagerie par résonance magnétique de diffusion : de l'acquisition comprimée au connectome

Paquette, Michael January 2017 (has links)
L’imagerie par résonance magnétique pondérée en diffusion est une modalité d’imagerie médicale non invasive qui permet de mesurer les déplacements microscopiques des molécules d’eau dans les tissus biologiques. Il est possible d’utiliser cette information pour inférer la structure du cerveau. Les techniques de modélisation locale de la diffusion permettent de calculer l’orientation et la géométrie des tissus de la matière blanche. Cette thèse s’intéresse à l’optimisation des métaparamètres utilisés par les modèles locaux. Nous dérivons des paramètres optimaux qui améliorent la qualité des métriques de diffusion locale, de la tractographie de la matière blanche et de la connectivité globale. L’échantillonnage de l’espace-q est un des paramètres principaux qui limitent les types de modèle et d’inférence applicable sur des données acquises en clinique. Dans cette thèse, nous développons une technique d’échantillonnage de l’espace-q permettant d’utiliser l’acquisition comprimée pour réduire le temps d’acquisition nécessaire.
93

Mise en œuvre de l'élastographie par résonance magnétique multifréquentielle au Centre hospitalier universitaire de Sherbrooke

Testu, Julien January 2017 (has links)
Ce projet vise à implanter l'élastographie par résonance magnétique (ERM) multifréquentielle au Centre hospitalier universitaire de Sherbrooke (CHUS), dans le but de pouvoir acquérir des données expérimentales sur des fantômes qui reproduisent les propriétés mécaniques du cerveau. La réalisation d'une élastographie de qualité nécessite le développement d'un système d'actionnement précis et facile d'utilisation pour créer une onde de cisaillement harmonique induite dans le tissu étudié. L'information sur les propriétés mécaniques est obtenue grâce à l'utilisation de la méthode de reconstruction d'inversion non linéaire par sous-zones (NLI). Cette méthode nécessite l'utilisation de la méthode des éléments finis pour calculer les propriétés mécaniques et requiert donc un traitement des données tirées de l'appareil d'imagerie par résonance magnétique (IRM), notamment une discrétisation du domaine étudié. Ce mémoire présente toutes les étapes réalisées afin d'être en mesure de réaliser une ERM multifréquentielle en partant du système générant l'excitation à l'intérieur de l'IRM, jusqu'au traitement post-reconstruction permettant d'obtenir la cartographie des propriétés mécaniques recherchées. Un système d'actionnement permettant de réaliser une ERM sur des fantômes de tofu a été conçu. Il a comme principales caractéristiques de produire des ondes mécaniques harmoniques dans une plage fréquentielle de 10 à 70 Hz de façon répétable. Parallèlement à la conception et la fabrication de ce système d'actionnement, de nombreuses reconstructions multifréquentielles ont été réalisées sur des données acquises sur des cerveaux humains, afin de trouver les paramètres optimaux de l'algorithme de reconstruction. Ces nombreuses analyses ont permis de mieux comprendre les paramètres limitant la reconstruction élastographique multifréquentielle, mais aussi de trouver et corriger des erreurs s'étant glissées dans la programmation de cet algorithme. Dans le but d'être un jour capable de réaliser une élastographie multifréquentielle sur une plage fréquentielle allant de 1 à 70 Hz, l'élastographie avec excitation intrinsèque a aussi été implantée au CHUS. Une analyse préliminaire, présentée dans ce document, a été réalisée à partir des données acquises avec cette technique.
94

Morphométrie de trois sillons d'intérêt dans la dyslexie développementale / Morphometry of three sulci of interest in developmental dyslexia

Scotto Di Covella, Lou 14 December 2016 (has links)
La dyslexie développementale est un trouble spécifique de l'apprentissage de la lecture qui affecte 3 à 7% des enfants d'âge scolaire. Il est bien établi aujourd'hui que la dyslexie découle en partie de variations génétiques qui causent des changements lors du développement cérébral, qui, à leur tour, ont des conséquences au niveau cognitif. Cette thèse s'appuie sur les analyses morphométriques de trois des sillons principaux du cerveau dans trois grands ensembles de données d'imagerie par résonance magnétique : 102 participants français, 80 participants polonais et 70 participants allemands, avec, dans chaque jeu de données, environ la moitié de participants ayant été diagnostiqués dyslexiques et la moitié de lecteurs normaux. J'ai étudié le sillon central, la scissure Sylvienne et le sillon temporal supérieur grâce aux outils de labellisation automatique et de mesures du logiciel BrainVISA. J'ai mesuré des propriétés quantitatives (surface et profondeur) ainsi que des propriétés qualitatives (configuration) de chaque sillon. J'ai montré une triple interaction entre groupe, sexe et hémisphère dans la profondeur moyenne du sillon central, laissant penser que les participants contrôles et dyslexiques diffèrent en terme d'asymétrie de profondeur de ce sillon. Comme la sulcation est un processus se déroulant de façon précoce lors du développement du cerveau et qui semble moins plastique que d'autres mesures cérébrales (comme, par exemple, les volumes de matière grise), ce résultat pourrait s'avérer être un marqueur précoce du risque de dyslexie plutôt que la conséquence de mauvaises capacités de lecture. / Developmental dyslexia is a specific disorder of reading acquisition that affects 3 to 7% of school-aged children. It is well established that dyslexia is partly caused by genetic variations whitch cause changes in brain development, whitch then have consequences at the cognitive level. This Ph.D thesis is based on morphometry analysis of three main sulci of the brain in three large databases of brain magnetic resonance images: 102 participants from France, 80 particpants from Poland and 70 participants from Germany, with, in each database, about half of participants were diagnosed with dyslexia and half of normal readers. I have studied the central sulcus, the Sylvian fissure and the superior temporal sulcus thanks to the automatic labelisation and measures tools in the BrainVISA software. I have measured some quantitative properties (surface and depth) as well as some qualitative ones (configuration) of each sulcus. I have shown a triple interaction between group, sex and hemisphere in the mean depth of the central sulcus. This result allows us to think that control and dyslexic participants may be different in terms of depth asymetry in this particular sulcus. Given that sulcation is an early process during brain development et that it seems to be less plastic than other brain measures (like, for example, grey matter volumes), this result may be an early marker of risk factors for dyslexia rather than a consequence of poor reading.
95

Développement de méthodes de spectroscopie par résonance magnétique localisée pour l’étude du métabolisme chez le petit animal / Development of localized magnetic resonance spectroscopy methods for the study of small animal metabolism

Joudiou, Nicolas 18 October 2013 (has links)
Le travail présenté ici a consisté en la mise au point d’une méthode de spectroscopie localisée proton filtrée carbone 13C chez la souris ainsi que de la mise en place d’un protocole pour des acquisitions, in vivo, de spectroscopie localisée en rotation à l’angle magique sur la drosophile. Le travail sur la souris a en particulier porté sur l’effet d’un traitement antivasculaire sur des tumeurs cérébrales. Pour réaliser cette étude il a également fallu concevoir une sonde de mesure (support + détecteur) spécialement dédiée à ce type d’étude. Le travail a permis de mettre en évidence l’apport de cette nouvelle méthode par rapport à la méthode classique de spectroscopie proton. Le travail sur la drosophile a permis la mise en place de la spectroscopie localisée par tranche, ce qui était l’objectif de départ, mais également la mise en place d’imagerie de déplacement chimique à 1 dimension spatiale, qui permet de réaliser une cartographie de la répartition spatiale des métabolites. Ces deux méthodes de spectroscopie sur la drosophile représentent à notre connaissance, deux premières, et ouvrent des perspectives importantes de recherche sur cet insecte qui est le plus utilisé dans le domaine, en particulier car il représente un très bon modèle génétique. / Here we present a 1H −13 C filtered method for localized spectroscopy for the study of mice brain metabolism and, also for the development of localized HRMAS spectroscopy methods for the in vivo study of drosophila. The aim of the work on mice was to study the effect of a vascular disrupting agent on glioma. We had to build a probe (cradle + detector) dedicated to this work. With this work we succeed to show the contribution of the 1H −13 C spectroscopic method, compared to the classical one, 1H spectroscopy. For the drosophila part of my work we succeed to perform slice selective spectroscopy on living drosophila using high Resolution Magic Angle Spinning, we even perform chemical shift imaging (1 spatial dimension) which give us a mapping of the metabolites distribution. As far we known, those methods represent two « premieres », and offer new perspectives of research on this insect, which is the most used in this field, particularly because of the numerous genetic studies on this animal.
96

Maladies péritonéales : place et apport de l'imagerie par résonance magnétique / Peritoneal diseases : place and contribution of magnetic resonance imaging

Rousset, Pascal 16 December 2015 (has links)
De nouvelles approches sont possibles en imagerie par résonance magnétique (IRM) pour répondre aux principaux enjeux diagnostiques et thérapeutiques liés aux maladies péritonéales. Cette technique implique l'utilisation de protocoles dédiés et une courbe d'apprentissage. Après une revue de la littérature sur l'imagerie péritonéale mettant en perspective la place de l'IRM et sa potentielle sous utilisation, l'objectif de ce travail a été d'étudier l'apport de cette technique dans deux modèles de maladies péritonéales diffuses. Le premier modèle concernait l'endométriose. En utilisant des protocoles adaptés, les études sur les atteintes digestives et diaphragmatiques ont démontré qu'une cartographie lésionnelle utile au diagnostic et à la prise en charge chirurgicale gynécologique pouvait être obtenue avec de hauts niveaux de performance. Le second modèle concernait la carcinose. La problématique était d'évaluer l'apport de l'IRM dans la sélection des patients candidats à une chirurgie menée à visée curative. La première étude menée sur une grande cohorte a démontré un très faible impact des différentes techniques d'imagerie dans la sélection des patients non résécables. La seconde étude, proposant une nouvelle approche de la quantification des lésions en combinant l'IRM au scanner, a rapporté une amélioration relative du bilan lésionnel, bien qu'encore infra optimale. Avec une approche qualitative centrée sur la recherche de signes de non résécabilité, la troisième étude a démontré que l'IRM avait une meilleure sensibilité que le scanner pour détecter les atteintes non résécables de l'intestin grêle dans le pseudomyxome péritonéal. L'IRM, grâce à sa haute résolution en contraste, offre des informations uniques. Utilisée comme technique de référence ou en complément des autres techniques en fonction de la nature des lésions à explorer, elle permet d'optimiser la prise en charge des patients / Magnetic resonance imaging (MRI) allows news approaches to improve diagnostic and therapeutic issues related to peritoneal diseases. This technique requires using dedicated protocols and has a learning curve. After a literature review on peritoneal imaging highlighting the role of MRI and its potential underutilization, the purpose of this work was to study the contribution of MRI in two models of diffuse peritoneal diseases. The first model concerned endometriosis. Using dedicated protocols, studies on digestive and diaphragmatic involvements reported high performance for providing a useful mapping of lesions for both diagnosis and surgical planning. The second model concerned peritoneal carcinomatosis. The purpose was to assess the contribution of MRI in selecting patients for curative surgery. The first study, performed in a large cohort, reported a very low impact of the different imaging techniques in the selection of non-resectable patients. Using a new approach combining MRI and computed tomography (CT), the second study demonstrated a substantial improvement in quantitative lesion assessment, although remaining sub optimal. With a qualitative approach evaluating signs of non-resectability, the third study showed MRI had better sensitivity than CT for the detection of non-resecable small bowel involvements in pseudomyxoma peritonei. MRI, thanks to its high contrast resolution, provides unique information. Used as reference technique or in addition to other techniques, MRI optimizes patient management
97

Caractérisation hémodynamique de l'aorte thoracique par IRM, tonométrie d'applanation et simulations numériques / Characterization of thoracic aortic hemodynamics using MRI, applanation tonometry and numerical modelling

Bollache, Emilie 24 January 2014 (has links)
L'aorte conduit le sang oxygéné aux organes et amortit l'onde pulsatile cardiaque. Au cours du vieillissement, elle est exposée à des altérations hémodynamiques et à une rigidité augmentée, elle-même associée à la mortalité.L'objectif de ma thèse est de proposer, à partir de l'IRM et des simulations, des indices non-invasifs de l'hémodynamique aortique locale, qui soient simples, rapides et complémentaires aux indices IRM de géométrie et de fonction aortiques établis.Un premier volet est consacré au développement et la personnalisation d'un modèle 1D de l'aorte descendante, validé qualitativement et quantitativement avec des données IRM sur 7 sujets, afin d'extraire des paramètres de pression, vitesse et surface.Un second volet, dédié aux données IRM, est centré sur :la comparaison de 7 méthodes d'évaluation de la pulsatilité aortique et leur validation avec la référence sur 70 sujets sainsla quantification du flux réverse aortique et l'étude de sa variation avec l'âge, ainsi que l'identification de ses déterminants sur 96 sujets sainsl'estimation automatique d'indices hémodynamiques de la sténose valvulaire aortique (SVA) et leur comparaison à l'échocardiographie Doppler sur 53 patients avec une SVA et 21 contrôles.Ainsi, le modèle aortique pourrait aider à identifier les déterminants des altérations aortiques et à consolider les observations in vivo. Par ailleurs, les outils mis au point pour l'analyse reproductible des données d'IRM fournissent des indices caractéristiques du vieillissement, qui pourraient être étudiés vis-à-vis des organes cibles (coeur, cerveau, rein, etc.) dans les pathologies cardiovasculaires (hypertension artérielle, drépanocytose). / The aorta conducts oxygenated blood to organs and also cushions the cardiac pulse wave. Such artery is exposed to age-related hemodynamic alterations and increased stiffness, which is associated with mortality. The objective of my PhD thesis is to propose, using MRI and numerical simulations, non-invasive indices of local aortic hemodynamics, which would be simple, fast and complementary to established aortic geometry and function MRI indices. A first work aims at developing and personalizing a 1D model of the descending aorta, as well as validating such model both qualitatively and quantitatively against MRI data acquired in 7 subjects, to eventually extract pressure, velocity and area parameters. A second work, which is based on MRI data, focuses on: the comparison of 7 methods for the evaluation of aortic pulsatility and their validation against the reference method in 70 healthy subjects, the quantification of aortic reverse flow and its variation with age, as well as the identification of its prime determinants in 96 healthy subjects, : the automated estimation of hemodynamic indices in aortic valve stenosis (AVS) as well as their comparison with the reference Doppler echocardiography, in 53 patients with AVS and 21 controls. Thus, the aortic model could help to identify determinants of aortic alterations and to strengthen in vivo observations. Besides, software tools developed for the reproducible analysis of MRI data provide indices that are characteristic of aging, and which could be studied in relation to end-target organs damage (heart, brain, kidney, etc.) in the setting of cardiovascular pathologies (hypertension, sickle cell disease).
98

Biominéralisation osseuse : de la caractérisation structurale du minéral à son organisation 3D / Bone biomineralization : from the structural characterization of the mineral to its 3D organization

Von Euw, Stanislas 17 November 2014 (has links)
Les travaux de cette thèse portent sur la caractérisation fine des cristaux d’apatite osseuse, principalement par résonance magnétique nucléaire à l’état solide. Leur originalité majeure a été de se tourner vers l’étude d’un échantillon d’os frais et intact, analysé dans les deux heures après son extraction de chez l’animal (i.e. une brebis âgée de deux ans). Cette démarche évite toute altération de l’échantillon d’os, lequel se trouve proche de son état d’hydratation naturel. Une telle rigueur expérimentale a permis de mettre en lumière le fort caractère hydrophile des cristaux d’apatite du minéral osseux. Un même caractère hydrophile a également été rapporté pour des analogues biomimétiques de synthèse étudiés dans un état humide artificiel. Il est prouvé ici que ce caractère hydrophile est fourni par la présence d’un domaine minéral particulier se trouvant en surface des cristaux d’apatite osseuse et biomimétique, appelé domaine non-apatitique. Les signatures RMN (des noyaux 31P et 1H) ainsi que les propriétés d’hydrophilie de ce domaine non-apatitique ont été comparées à celles d’un échantillon de phosphate de calcium amorphe de synthèse, et se sont avérées similaires. Une étude sur la composition chimique de ce domaine non-apatitique a également été entreprise, réalisée parfois sur un échantillon d’os intact et parfois sur des analogues biomimétiques de synthèse enrichis en certains isotope (i.e. 13C et 43Ca). Il a de cette manière été montré que ce domaine non-apatitique est principalement composé d’espèces divalentes : Ca2+, HPO42- et CO32-. Enfin, des expériences de diffraction des rayons X et de cryo-microscopie électronique en transmission ont permis d’étudier le comportement en solution des cristaux d’apatite. Il a de cette manière été prouvé, de manière inattendue, que les molécules d’eau rigidement adsorbées sur le domaine de surface des cristaux d’apatite peuvent favoriser l’adhésion entre les cristaux ainsi que leur organisation 3D. / The work of this thesis is focused on the characterization of bone apatite crystals, mainly by solid-state nuclear magnetic resonance. The originality of this work was to study a fresh bone sample, analyzed within two hours after its extraction from the animal (i.e. a two years old sheep). This approach avoids any alteration of the bone sample, and keeps its natural state of hydration. Such experimental rigor led to the evidence that the apatite crystals of bone own a high hydrophilic character. Furthermore, a analogous hydrophilic character has also been reported for two samples of biomimetic apatites, both studied in a artificial wet state. It is shown here that this hydrophilicity is given by the presence of a particular mineral domain located at the surface of the bone apatite (and biomimetic apatite) crystals, the so called non-apatitic domain. The NMR signatures (1H and 31P nuclei) and the hydrophilic properties of the non-apatitic domain were compared with those of a synthetic amorphous calcium phosphate, and all were found to be similar. The chemical composition of the non-apatitic domain was also studied, sometimes performed on a bone sample and sometimes on labeled (13C and 43C) biomimetic apatites. It has been shown that this non-apatitic domain is mainly composed of divalent species : Ca2+ , CO32- and HPO42-. Finally, some X-ray diffraction and cryo-electron transmission microscopy experiments were done to study the behavior of apatite crystals in aqueous media. It has been shown, surprisingly, that the water molecules strongly adsorbed on the non-apatitic domain at the surface of apatite crystals, can promote the adhesion between crystals and their 3D organization.
99

Méthodes de segmentation du ventricule gauche basée sur l'algorithme graph cut pour les images par résonance magnétique et échocardiographiques

Bernier, Michaël January 2017 (has links)
L’échocardiographie et l’imagerie par résonance magnétique sont toutes deux des techniques non invasives utilisées en clinique afin de diagnostiquer ou faire le suivi de maladies cardiaques. La première mesure un délai entre l’émission et la réception d’ultrasons traversant le corps, tandis que l’autre mesure un signal électromagnétique généré par des protons d’hydrogène présents dans le corps humain. Les résultats des acquisitions de ces deux modalités d’imagerie sont fondamentalement différents, mais contiennent dans les deux cas de l’information sur les structures du coeur humain. La segmentation du ventricule gauche consiste à délimiter les parois internes du muscle cardiaque, le myocarde, afin d’en calculer différentes métriques cliniques utiles au diagnostic et au suivi de différentes maladies cardiaques, telle la quantité de sang qui circule à chaque battement de coeur. Suite à un infarctus ou autre condition, les performances ainsi que la forme du coeur en sont affectées. L’imagerie du ventricule gauche est utilisée afin d’aider les cardiologues à poser les bons diagnostics. Cependant, dessiner les tracés manuels du ventricule gauche requiert un temps non négligeable aux cardiologues experts, d’où l’intérêt pour une méthode de segmentation automatisée fiable et rapide. Ce mémoire porte sur la segmentation du ventricule gauche. La plupart des méthodes existantes sont spécifiques à une seule modalité d’imagerie. Celle proposée dans ce document permet de traiter rapidement des acquisitions provenant de deux modalités avec une précision de segmentation équivalente au tracé manuel d’un expert. Pour y parvenir, elle opère dans un espace anatomique, induisant ainsi une forme a priori implicite. L’algorithme de Graph Cut, combiné avec des stratégies telles les cartes probabilistes et les enveloppes convexes régionales, parvient à générer des résultats qui équivalent (ou qui, pour la majorité des cas, surpassent) l’état de l’art ii Sommaire au moment de la rédaction de ce mémoire. La performance de la méthode proposée, quant à l’état de l’art, a été démontrée lors d’un concours international. Elle est également validée exhaustivement via trois bases de données complètes en se comparant aux tracés manuels de deux experts et des tracés automatisés du logiciel Syngovia. Cette recherche est un projet collaboratif avec l’Université de Bourgogne, en France.
100

Synthèse et étude de récepteurs tritopiques de type bis-calix[6]tris-(thio)urée

Moerkerke, Steven 18 March 2016 (has links) (PDF)
Ce travail s’inscrit dans le cadre de la chimie supramoléculaire, domaine qui traite des systèmes comportant deux ou plusieurs entités moléculaires, organisées et maintenues ensemble par des interactions intermoléculaires non covalentes. Ces interactions sont très répandues dans les systèmes naturels et de nombreux récepteurs moléculaires synthétiques ont été développés afin d’améliorer la compréhension des différents processus de reconnaissance hôte-invité. Parmi ces récepteurs, les calix[6]arènes sont des candidats de choix car ils possèdent une cavité hydrophobe idéale pour l’inclusion de petites molécules organiques. De plus, de nombreuses méthodes de synthèse ont été mises au point pour les modifier chimiquement. Un certain nombre de travaux publiés dans la littérature ont porté sur la synthèse de récepteurs multitopiques à base de deux sous-unités calixaréniques reliées entre elles :les bis-calixarènes. L’objectif consiste à obtenir des tubes possédant des propriétés de complexation inédites. Parmi les composés préalablement étudiés au sein du Laboratoire de Chimie Organique, le bis-calix[6]tris-amide est le premier exemple de récepteur multitopique, car il permet l’inclusion d'un ammonium et de son contre-ion selon un processus de reconnaissance de paires d'ions associés, mais également l'inclusion d'un second ammonium pour obtenir des complexes cascade, dans un solvant apolaire (CDCl3). Cependant, ces propriétés de reconnaissance sont particulièrement limitées dans un solvant protique (CD3OD), restreignant de ce fait leur applicabilité.L’objectif de nos travaux a été de synthétiser et d’étudier les propriétés hôte-invité de nouveaux dérivés bis-calix[6]aréniques, modifiés à diverses positions, afin de moduler et renforcer les propriétés de reconnaissance, notamment en milieu protique. Pour ce faire, cinq nouveaux récepteurs ont été développés. Tout d’abord, le remplacement des trois liens amide par trois liens urée ou thiourée a permis d'améliorer la reconnaissance d’une grande variété de paires et triades d’ions organiques, grâce à un remarquable phénomène d’adaptation induite et avec une sélectivité importante pour les ammoniums linéaires associés à un anion dichargé. Les processus de complexation sont hautement coopératifs et sont en grande partie dirigés par l’interaction ionique. L'étude approfondie de ces récepteurs a permis de mieux comprendre le mode d'insertion des ammoniums qui s’insèrent très probablement dans les cavités en passant par les petits cols calixaréniques, le méthyle terminal en premier. Ces deux récepteurs sont également aptes à complexer des ammoniums quaternaires fonctionnalisés et des zwittérions de type bétaïne :l’ammonium est alors reconnu au sein d’une des deux cavités aromatiques tandis que le second groupe fonctionnel interagit avec le site tris-(thio)urée. La reconnaissance sélective de lipides de type phosphatidylcholine a également été mise en évidence. Il est très intéressant de noter que ces récepteurs constituent un très bel exemple de biomimétisme, avec un mode de reconnaissance très proche de celui des transporteurs naturels de ces molécules. D’autre part, le bis-calix[6]tris-thiourée peut également servir de détecteur capable de discriminer divers anions en présence d'un petit ammonium primaire dans le chloroforme.En présence de deux sites tris-urée sur chaque bras reliant les deux sous-unités calixaréniques, la formation de complexe quaternaire avec des bis-anions de type disulfate ou dicarboxylate a été observée tandis qu’en supprimant les groupes méthyle des petits cols calixaréniques via une réaction de déméthylation sélective, le bis-calixarène hexa-déméthylé possède une meilleure affinité pour les triades d’ions d’ammoniums secondaires et quaternaires, grâce à la plus grande flexibilité de ce récepteur par rapport à son équivalent hexa-méthylé. Enfin, l’introduction de bras fonctionnalisé sur le bis-calix[6]arène tris-urée a permis de former sélectivement des complexes quaternaires de type [1+1+1+1] en incluant deux ammoniums différents. / Doctorat en Sciences / info:eu-repo/semantics/nonPublished

Page generated in 0.3767 seconds