Spelling suggestions: "subject:"radioterapia"" "subject:"radioterapias""
581 |
Eletronterapia intraoperatória adjuvante no carcinoma inicial invasivo de mama: tolerabilidade, satisfação estética e eficiência terapêutica / Adjuvant intraoperative electron-beam therapy for early invasive breast carcinoma: toxicity, therapeutic efficacy and aesthetic satisfactionHanna, Samir Abdallah 31 January 2014 (has links)
INTRODUÇÃO: A razão para a radioterapia parcial da mama em comparação ao tratamento convencional da mama inteira baseia-se em 3 pontos: a) cerca de 90% das recidivas locais ocorre na adjacência do tumor primário; b) é possível estabelecer a equivalência de efetividade entre a dose única e o tratamento fracionado convencional; e c) existem dificuldades logísticas, financeiras e emocionais no tratamento fracionado convencional (falta da disponibilidade do aparelho de radioterapia em muitos municípios e desistência de tratamento das mulheres que iniciam a radioterapia convencional). Em maio de 2004 iniciou-se um estudo prospectivo com a eletronterapia intraoperatória adjuvante no carcinoma inicial invasor de mama, porém com sistemática de tratamento diferente de outras técnicas: ao invés de se usar um acelerador linear portátil e dedicado, utilizou-se o acelerador linear estático convencional. Neste trabalho, buscou-se analisar a frequência de complicações imediatas e tardias; o grau de satisfação estética das pacientes com as mamas após o tratamento; e as taxas de sobrevida livre de doença e sobrevida livre de falha local. MÉTODOS: Coletaram-se dados dos prontuários, buscando informações demográficas, do estadiamento inicial, da avaliação histopatológica intraoperatória (margens cirúrgicas e linfonodo sentinela), dados técnicos da eletronterapia e os achados finais em exame de parafina. Além disso, a frequência de complicações imediatas (até um mês de cirurgia) e tardias (depois de um mês), a estética (um ano da cirurgia, usando a escala de Harvard/NSABP/RTOG) e finalmente os índices de sobrevida global e livre de evento. RESULTADOS: Foram incluídas 169 pacientes e destas 35 foram excluídas devido a critérios intraoperatórios (linfonodo sentinela positivo ou margens positivas). Assim, 134 foram analisadas com idade mediana de 57,9 (40-85,4) anos, em um seguimento mediano de 50,6 (1-97,2) meses. Quatro pacientes desenvolveram recidiva local e três tiveram recorrência regional. As estimativas actuariais em 5 anos de sobrevida global, livre de eventos e livre de falha local foram respectivamente 97, 90,5 e 93,6%. A incidência cumulativa de falha local em 5 anos foi de 3,7%. A incidência global de toxicidade aguda foi de 8,2% e tardia de 26,2%. Os resultados estéticos excelentes, bons, regulares e ruins observados foram respectivamente 70,9%, 14,2%, 3,7% e 3,0%. Os tamanhos de colimador utilizados foram 4 cm em 18,7%, 5 cm em 80,6% e 7 cm de 0,7% dos casos. A energia de elétrons escolhida para tratamento foi de 6 MeV em 7,4%, 9 MeV em 52,2%, 12 MeV em 35,8%, 15 MeV em 3,7%, e 18 MeV em 0,7%. Os aceleradores lineares dedicados apresentam opção de energia de elétron variando até 9 MeV. Sendo assim, 40,29% dessa amostra provavelmente seria sub-tratada em equipamentos dedicados, pois foram necessários valores maiores de energia de elétrons para um tratamento adequado. Todas as pacientes fizeram portal-filme para checagem antes do tratamento e em 72,4% o alinhamento entre o disco de proteção e o colimador foi suficiente. No entanto, 27,6% das pacientes tiveram que ter os discos reposicionados. Nenhum caso de infecção no período perihospitalar fora observado. CONCLUSÕES: A eletronterapia intraoperatória com acelerador linear convencional apresentou baixa frequência de complicações e resultados estéticos desfavoráveis, e foi oncologicamente efetiva / INTRODUCTION: The rationale for partial breast radiation therapy when compared to conventional whole breast treatment is based on three points: a) about 90% of local recurrences occur in the adjacent area of the primary tumor, b) it is possible to establish equivalence between the effectiveness of single dose and fractionated conventional treatment, and c) there are logistical, financial and emotional difficulties related to conventional fractionated treatment (lack of availability of radiotherapy facilities in many cities and the high dropout rate of women who start conventional radiotherapy). In May 2004 we started a prospective trial using adjuvant intraoperative electron-beam therapy in early invasive breast cancer, but instead of a dedicated linear accelerator, we used the static conventional linear accelerator. In this study, we aimed to analyze the frequency of early and late complications, the cosmetic satisfaction of patients after treatment, and freedom from disease and local recurrence rates. METHODS: Data were collected from medical records, looking for demographic information, the initial stage, intraoperative and definitive histopathological evaluation of surgical margins and sentinel lymph node, technical data and pathologic staging, and follow-up data. In addition, the frequency of immediate (up to one month of surgery) and late (after one month) complications, aesthetics (one year of surgery, using the scale of Harvard/NSABP/RTOG), and finally the event-free and overal survival were obtained. RESULTS: We included 169 patients and 35 of these were excluded due to intraoperative criteria (positive sentinel lymph nodes or margins). Thus, 134 were analyzed. The median age was 57.9 (40 to 85.4) years and the median follow-up was 50.6 (1 to 97.2) months. Four patients developed local recurrence and three had regional recurrence. The actuarial estimates for overall, event-free, and local failure-free survivals were respectively 97, 90.5, and 93.6%. The crude incidence of local failure at 5 years was 3.7%. The overall incidences of acute and late toxicities were respectively 8.2% and 26.2%. The cosmetic results as excellent, good, fair and bad respectively were observed in 70.9%, 14.2%, 3.7% and 3.0%. Collimator sizes were 4 cm in 18.7%, 5 cm in 80.6%, and 7 cm in 0.7% of cases. The electron energy chosen for treatment was 6 MeV in 7.4%, 9 MeV in 52.2%, 12 MeV in 35.8%, 15 MeV in 3.7% and 18 MeV in 0.7%. The dedicated linear accelerators have electron beam energy ranging up to 9 MeV. Thus, 40.29% of these patients probably would not be treated adequately in dedicated equipment due to the need for higher values of electron energy. All patients underwent portal-film and in 72.4% the alignment between the shielding disc and the collimator was enough. However, in 27.6% of patients it had to be repositioned. No case of infection was observed during perihospitalar time. CONCLUSIONS: Intraoperative electrontherapy using conventional linear accelerator has shown low complications and worsening aesthetics rates, and oncologic efficacy
|
582 |
Dosimetria dos sistemas de radiocirurgia estereotáxica com aceleradores lineares equipados com colimadores micro multi-lâminasAndré Mozart de Miranda Vieira 19 February 2008 (has links)
Neste trabalho, as doses absorvidas produzidas em água pelo feixe de radiação de um Acelerador Linear Clínico - CLINAC 600C TM (Varian), com feixes de fótons de 6MV, foram avaliadas teórica e experimentalmente em configurações de campos quadrados, em seguida, em configurações de campos estreitos e circulares, obtidos com um colimador micro multi-lâminas - mMLC m3TM (BrainLab). A avaliação teórica foi feita por meio de cálculos com o Método de Monte Carlo. As curvas de porcentagem de dose profunda PDP e respectivas razões tecido máximo TMRs derivadas, do CLINAC 600C, medidas experimentalmente, foram validadas por meio de comparações com valores de referência, bem como com medidas usando diferentes detectores. Os resultados indicam diferenças menores que 5% pontualmente e em média menores que 1,5% para cada campo avaliado, quando comparados aos valores do comissionamento anterior (realizado no ano de 1999) e aos valores da literatura. Na comparação das medidas feitas com câmara de ionização e com diodo, a média das diferenças pontuais das curvas de PDP foi de -0,6% e as diferenças entre os perfis laterais de dose ficaram dentro de 1%, na região plana. O diodo fornece medidas de perfil com melhor resolução espacial. Os fatores relativos de dose dos campos abertos, atualizados, concordam com os valores de referência anteriores dentro de 1,03% de discrepância. As curvas de distribuição de dose absorvida em água, atualizadas, são, agora, consideradas de referência e permitem caracterizar o feixe desse CLINAC para o cálculo de dose em pacientes. Os espectros de fótons resultantes das simulações por Monte Carlo com os códigos PENELOPE e MCNP concordam em aproximadamente 80% dos pontos amostrados, sendo que as energias médias de (1,6 ± 0,3)MeV, com o MCNP, e de (1,72 ± 0,08)MeV, com o PENELOPE, são coincidentes. O modelo de fonte simples do CLINAC 600C, criado com o código PENELOPE, permite calcular as distribuições de dose em água, de campos abertos, com discrepâncias da ordem de ±1,0% na dose e de ±0,1 cm na posição, se comparados a medidas experimentais. Esses valores de discrepância atingem os critérios propostos inicialmente para validar o modelo de simulação e garantir sua aplicabilidade nas avaliações dosimétricas da Radioterapia desse CLINAC. A descrição geométrica do mMLC m3 para fins de simulação pelo Método de Monte Carlo, utilizando o código PENELOPE, foi considerada satisfatória ao permitir avaliar a transmissão desse colimador dentro de uma incerteza de ±0,2% e calcular uma subdosagem média de (11,4±2,0)%, devida ao efeito lingüeta-vão, que coincide com o valor determinado experimentalmente de (12,5±2,7)%, específicos para esse projeto de colimador. Os programas de simulação por Monte Carlo, que fazem o uso de um modelo de fonte simples do CLINAC 600C, combinado com o modelo completo do mMLC m3, permitiram calcular PDPs em água, de campos conformados, dentro do intervalo de ±1% de discrepância, enquanto que os fatores relativos de dose de campos conformados pelo mMLC puderam ser calculados com incertezas que variam de 1 a 3% concordando com os valores experimentais. Esses campos avaliados representam campos próximos àqueles usados nos tratamentos. Os resultados do trabalho garantem um conhecimento dosimétrico maior do colimador micro multi-lâminas m3, utilizado nas técnicas de radioterapia e radiocirurgia estereotáxica tridimensionais, e fornece uma ferramenta útil na avaliação das doses produzidas em configurações de campos complexas. / In this work, absorbed dose to water produced by the radiation beam of a clinical linear accelerator - CLINAC 600C TM (Varian), with a photon beam of 6 MV, were evaluated both theoretically and experimentally. This determination includes square and circular field configurations, the last one obtained with a micro multileaf collimator - mMLC m3TM (BrainLab). Theoretical evaluation was performed throughout Monte Carlo method. Experimental measurements of Percentage Depht Dose - PDD and derived Tissue Maximum Ratio - TMR curves from CLINAC 600C were validated by comparison with reference values as well as with measurements using different detectors. The results indicate local differences smaller than 5% and average differences smaller than 1,5% for each evaluated field, if they are compared to the previous commissioning values (made in 1999) and to the values of literature. Comparisons of ionization chamber and diode result in an average local difference of -0,6% for PDD measurements, and within 1% for lateral dose profiles, at depth, in the flat region. Diode provides measurements with better spatial resolution. Current output factors of open fields agree with reference values within 1,03% of discrepancy level. Current absorbed dose distributions in water are, now, considered reference values and allow characterization of this CLINAC for patient dose calculation. The photon spectra resulting from simulations with PENELOPE and MCNP codes agree approximately in 80% of the sampled points, in what average energies of (1,6 ± 0,3)MeV, with MCNP, and of (1,72 ± 0,08)MeV, with PENELOPE, are coincident. The created simple source model of the CLINAC 600C, using the PENELOPE code, allows one to calculate dose distributions in water, for open fields, with discrepancies of the order of ±1,0% in dose and of ±0,1cm in position, if they are compared to experimental measurements. These values met the initial proposed criteria to validate the simulation model and guarantee its applicability in dosimetric evaluations of radiotherapy with this CLINAC. The geometrical description of the mMLC m3 for Monte Carlo purposes, using the PENELOPE code, was considered satisfactory, providing the characterization of relevant physical parameters such as the transmission of the mMLC, within an estimated uncertainty of ±0,2%, and the average underdose of (11,4±2,0)%, due the tongue and groove effect, which is coincident with the experimental value of (12,5±2,7)%, for this particular collimator design. The Monte Carlo simulation codes which combine a single source model of the CLINAC 600C with the full m3 model, allows to calculate dose distributions in water for conformal beams within the discrepancy level of ±1%. However, output factors of conformal beams with the mMLC can be calculated with uncertainties varying from 1 to 3%, when they are compared to experimental results. These evaluated fields represent, and come close to treatment fields. The results of this work guarantee a better dosimetric knowledge of the micro multileaf collimator m3, which is used in three-dimensional stereotactic radiotherapy and radiosurgery techniques. This provides a useful tool in the evaluation of the mMLC as well as the absorbed doses produced in complex field configurations.
|
583 |
Intercomparação de colimadores de múltiplas lâminas para implementação de terapia de feixes de intensidade modulada / Multileaf collimator intercomparison for intensity modulated radiation therapy implementationJuan Fernando Delgado Viteri 10 January 2006 (has links)
Neste trabalho é apresentada uma intercomparaçào das características dosimétricas entre três sistemas de colimadores multi-lâminas: Varian Millenium com 120 lâminas, mMLC m3 Brainlab e Varian Mark II ambos com 52 lâminas. A largura da projeção das lâminas no isocentro e na região central do campo é de 0,5 cm; 0,35 cm e 1,0 cm respectivamente. Foram comparadas características dosimétricas comuns aos três sistemas em modo estático e, no modo dinâmico, o trabalho limitou-se aos dois primeiros. Em modo dinâmico, foram realizados testes que avaliam o funcionamento através da irradiação em filme de figuras padrão, como a reprodutibilidade e estabilidade do MLC. Foi testada a linearidade das UM, sensibilidade â interrupção de tratamentos, a constância na velocidade das lâminas encontrando-se em todos os casos dentro do ±3%. Na linearidade da taxa de dose existem diferenças quando este parâmetro diminui. Encontrou-se que o desvio médio da dose é inversamente proporcional à abertura média dos campos dinâmicos. O fator de rendimento em modo dinâmico apresentou variações de até 1% quando o sistema suporte funcional se encontrava em posições laterais. Para os três sistemas de MLC, nos perfis para um mesmo tamanho de campo foi observada uma inclinação maior na região de penumbra para o mMLC; nos fatores de rendimento existem também pequenas diferenças de um sistema para outro. A abertura dosi métrica entre pares de lâminas foi determinado para o MLC 120, mMLC e MLC 52, os valores obtidos para 6 MV foram: (0,202 ± 0,054) cm; (0,157 ± 0,070) cm e (0,189 ± 0,081) cm respectivamente. A transmissão apresentou um comportamento crescente com a profundidade e o tamanho de campo para 6 MV nos três sistemas. Os valores médios determinados com câmara de ionização para 6 MV foram os seguintes: (1,630 ± 0,018)% para o MLC 120; (1,291 ± 0,029)% para o mMLC e (1,638 ± 0,010)% para o MLC 52. Quando testada com filme, a transmissão entre as lâminas e intralâminas apresentou dependência com a posição fora do eixo central tanto no MLC 120 quanto no mMLC. A porcentagem de espalhamento produzido pelo MLC, com relação a um campo aberto de referência de 6 MV foi: (0,297 ± 0,024)% para o MLC 120; (0,239 ± 0,052)% para o mMLC e (0,202 ± 0,028)% para o MLC 52. A penumbra (80-20%) em função do deslocamento fora do eixo não apresentou variações significativas nos três sistemas. Para todos os MLCs, a penumbra apresentou um comportamento crescente em função do tamanho de campo definido pelas lâminas. Em função da profundidade em 6 MV, a penumbra apresentou o menor valor para o mMLC em d max: 2,59 mm e o maior é 6,74 mm para o MLC Mark II a 10 cm de profundidade. A penumbra em função do ângulo que as lâminas formam com o seu eixo de movimento, para o ângulo de 10° no mMLC apresentou um valor 3,74 mm; já para os ângulos maiores, os maiores valores foram os obtidos para o Mark II. A série de testes descrita no presente trabalho permite estabelecer uma rotina no comissionamento de sistemas de MLC que pode ser aplicada nos serviços de Radioterapia que vão comissionar sistemas de MLC para IMRT em modo dinâmico. Os resultados descritos permitem caracterizar cada um dos sistemas de MLC estudados. Não é possível dizer que um sistema é melhor que outro, mas é possível, a partir da escolha de um deles, identificar as possíveis vantagens e desvantagens que cada um vai apresentar. / In this work a dosimetric comparison between three multileaf collimator systems is presented: a Varian Millennium with 120 leaves, Brainlab mMLC m3 and Varian Mark II both with 52 leaves. The width projection at isocenter level in field\'s central region are: 0,5 cm; 0,35 cm and 1,0 cm respectively. Common dosimetric characteristics for the three systems in static mode and dynamic capabilities for the two first were compared. In dynamic mode, tests validating proper MLC function through film irradiation were done, such MLC stability, MU linearity, treatment interruptions sensitivity, stability of MLC in dynamic mode, leaf speed stability, were found within ±3% deviation in all cases. Dose rate linearity showed differences when this parameter decreases in dynamic mode. Average dose errors for fixed width gaps moving at constant speed were found to be proportional to gap errors and inversely proportional to the gap width. Output factors differences delivered through a sweeping gap were found less than ±1% when the gantry was in a lateral position. For the three MLC systems, when comparing beam profiles for the same field was observed that for mMLC presents the sharpest dose gradient region. In the output factors small differences where observed in every MLC system. Dosimetric leaf gap was determined for MLC 120, mMLC and MLC 52, obtained values for a 6 MV beam are: (0,202 ± 0,054) cm; (0,157 ± 0,070) cm and (0,189 ± 0,081) cm respectively. The transmission showed an increase with depth and field width for 6 MV in all the three systems. Average values obtained with ionization chamber for this energy were: (1,630 ± 0,018)% for MLC 120; (1,291 ± 0,029)% for mMLC and (1,638 ± 0,010)% for MLC 52. When obtained through film irradiation, inter and intra leaf transmission showed an off axis dependent behavior for MLC 120 and mMLC. Scatter produced by MLC as a 6 MV open reference field ratio was: (0,297 ± 0,024)% for MLC 120; (0,239 ± 0,052)% for mMLC and (0,202 ± 0,028)% for MLC 52. It was verified that penumbra width (80-20%) as a function of off axis leaf position do not showed significant differences in all systems. As a function of field width defined by MLC leaves, penumbra width presented an increasing behavior. When tests as a depth function in a 6 MV field, penumbra showed the smallest value for the mMLC at dmax: 2,59 mm and the biggest was 6,74 mm for the MLC Mark II AT 10 cm depth. Penumbra dependence with leaf movement axis showed that for 10 deg, the mMLC presented a 3,74 mm value, for larger angles, the higher values were obtained for MLC Mark 11. Described series of tests described in the present investigation allows to establish a commissioning routine for MLC systems, that could be applied in a Radiotherapy Department that will commission those systems for dynamic IMRT. Obtained results allow to characterize every MLC studied system. It is not possible to establish which system is better, but when one is chosen it is feasible to identify vantages and disadvantages that everyone will present.
|
584 |
Associação de marcadores de proliferação e de apoptose com a resposta à radioterapia e sua importância prognóstica em carcinoma epidermóide de palato mole / Proliferation and apoptosis markers in association with radiotherapy response and their prognostic importance in squamous cell carcinoma of soft palateCortelazzo, Marco Antonio 18 April 2007 (has links)
Carcinoma epidermóide de palato mole é relativamente raro, representando em torno de 15% das neoplasias da orofaringe, onde predominam os tumores de base de língua e tonsila palatina. Não há consenso sobre a melhor forma de tratamento para estes tumores, pois apesar de todos os avanços e associações terapêuticas, as taxas de sobrevida têm se alterado pouco nas últimas décadas. Mesmo com os avanços da cirurgia reparadora, minimizando as seqüelas da cirurgia oncológica, a radioterapia exclusiva e/ou associada à quimioterapia é a forma de tratamento mais utilizada em muitos serviços, principalmente para os tumores em estádio clínico avançado. Entretanto, muitos pacientes não apresentam resposta a tal terapêutica. Desse modo, selecionar um grupo de pacientes com maiores possibilidades de resposta à irradiação poderia orientar a melhor indicação terapêutica para cada caso. Sendo assim, os objetivos desse trabalho são avaliar as características demográficas, clínicas, histológicas e a expressão imunoistoquímica das proteínas p53, Ki-67, Bcl-2 e Bax como fatores preditivos de resposta ao tratamento e de sobrevida, em pacientes portadores de carcinoma epidermóide de palato mole submetidos à radioterapia com finalidade curativa. Foram selecionados, retrospectivamente, 73 prontuários de pacientes portadores de carcinoma epidermóide de palato mole admitidos para tratamento no Departamento de Cirurgia de Cabeça e Pescoço e Otorrinolaringologia do Hospital A. C. Camargo, em São Paulo, no período de janeiro de 1970 a dezembro de 2000 que foram submetidos à radioterapia com finalidade curativa e que apresentavam tecido biopsiado, previamente ao tratamento, viável para a confecção e análise da expressão imunoistoquímica dos marcadores em questão, em lâminas de tissue microarray. As variáveis idade, sexo, raça, tabagismo, alcoolismo, grau histológico (G), categoria T e N e estádio clínico (EC) foram correlacionadas com a expressão imunoistoquímica destes marcadores. A idade média dos pacientes foi de 60 anos, com predomínio de pacientes do sexo masculino (83,6%), raça branca (80,8%), tabagistas (86,3%), alcoolistas (76,7%), G1+2 (69,9%) e em EC avançado da doença (72,6%). Não houve diferença estatisticamente significativa entre a expressão dos marcadores em questão e as variáveis estudadas. As análises univariadas de sobrevida em 5 anos evidenciaram que a sobrevida específica por câncer (SEC) foi de 27,1%, sendo significativamente melhor para os pacientes portadores de tumores em categoria T e N iniciais e em estádios clínicos iniciais. A sobrevida global (SG) foi de 24,9% sendo significativamente melhor nos pacientes portadores de tumores em estádios clínicos iniciais. Em relação à imunorreatividade dos marcadores estudados, não observamos diferenças estatisticamente significativas quanto à sobrevida específica por câncer e global. A análise multivariada da SEC em 5 anos evidenciou que EC avançado, grau histológico G3 e imunoexpressão de p53 foram variáveis independentes, associadas a pior prognóstico (p < 0,100). Para a sobrevida global, somente EC avançado foi identificado como variável independente associada a pior prognóstico. Conclusão: pacientes com tumores em estádios clínicos iniciais e/ou G1+2 e/ou que não expressam p53 têm melhor prognóstico. / Squamous cell carcinoma of the soft palate is rare and represents about 15% of the oropharynx cancer, where there is prevalence of tumors of the base of tongue and palatine tonsil. There is no consensus about the best form of treatment for these tumors because, despite all advances and therapeutic associations, there has not been major changes in overall survival in the last decades. In spite of the advances of reconstructive surgery, which has reduced the sequelae of oncologic surgery, radiotherapy alone or in association with chemotherapy are the most used treatments, especially for tumors in advanced clinical stage, mostly because of the sequelae of surgical treatment. However, many patients have a poor response to this therapeutic. This way, selecting a group of patients with more possibilities of response to irradiation could be used in the selection of the best therapeutic for each case. Because of this, the objective of this paper is to evaluate demographic, clinical and histological characteristics and the immunoistochemical expression of p53, ki-67, Bcl-2 and Bax proteins as predictive factors of response to treatment and survival in patients with squamous cell carcinoma of soft palate submeted to radiotherapy with curative intent. We selected, retrospectively, 73 clinical charts of patients with squamous cell carcinoma of soft palate admitted for treatment in the Department of Head and Neck and Otorrinolarynxlogy Surgery of A. C. Camargo Hospital, in São Paulo, from 1970 to 2000, submitted to radiotherapy with curative intent and who had tissue biopsy - before treatment - which had a viable paraphin block analyze the immunoistochemical expression of the studied markers, in plates of tissue microarray. Variables as age, sex, race, smoking, alcoholism, histological degree, T and N categories and clinical stage were correlated with the immunoistochemistry expression of these markers. Mean age was 60 years, mostly patients were males (83.6%), white (80.8%), smokers (86.3%), alcoholics (76.7%), the histologic degree was G1 and G2 (69.9%) and most were diagnosed in advanced clinical stages (72.6%). There was no statistically meaningful difference between the expression of the studied markers and the studied variables. Univaried analysis of survival in 5 years showed that cancer specific survival was 27.1%, which was significantly better for those patients with tumors in early T and N categories and initial clinical stages. Overall survival was 24.9%, significantly better for patients with tumors in initial clinical stages. About the immuno-reactivity of the studied markers, we did not find statistically significant differences for overall survival cancer and specific survival. Multivaried analysis of cancer specific survival in 5 years showed that advanced clinical stage, histological degree 3 and p53+ were independent variables, associated with a worst prognosis (p<0.100). For overall survival, only advanced clinical stage was an independent prognostic variable. Conclusion: patients with tumors in advanced clinical stages and/or histological degree 1 + 2 and/or that do not express p53 have a better prognosis.
|
585 |
Toxicidade pulmonar da radioterapia conformacional torácica em mulheres com câncer de mama. Repercussões funcionais, tomográficas, sistêmicas e seus reflexos na qualidade de vida / Pulmonary toxicity of thoracic conformal radiotherapy in women with breast cancer. Functional, tomographic and systemic impacts and its effects on quality of life.Chaves, Adriana Assis Miranda 24 October 2013 (has links)
O tratamento radioterápico continua aperfeiçoando-se, porém ainda pode estar associado com toxicidade pulmonar. Objetivo: Estudar os efeitos locais e sistêmicos provocados pela radioterapia conformacional torácica adjuvante em mulheres portadoras de câncer de mama, sem fatores de riscos prévios para desenvolvimento de alterações pulmonares. Por meio da tomografia computadorizada de alta resolução; identificar as possíveis alterações radiológicas no parênquima pulmonar. Se presentes, correlacioná-las com parâmetros obtidos da exploração funcional dos pulmões, com os efeitos sistêmicos, pela dosagem de mediadores inflamatórios, IL-1, IL-6 e TNF- , e suas repercussões sobre a qualidade de vida. Material e Métodos: Em 25 pacientes saudáveis foram coletadas amostras de sangue para serem utilizadas apenas como referência de normalidade da IL-1, IL-6 e TNF- . Em decorrência dos rígidos critérios de inclusão e exclusão estabelecidos, das 157 pacientes entrevistadas apenas 24 foram selecionadas para o estudo. A avaliação funcional pulmonar foi abrangente e constou de: medida dos volumes e capacidade dos pulmões, sendo o volume residual obtido pelo método de diluição do hélio em circuito fechado; estudo dos fluxos expiratórios máximos (curva fluxo x volume e curva volume x tempo) e medida da capacidade de difusão pulmonar pela técnica de respiração única do CO. A tomografia computadorizada de alta resolução (16 detectores) foi realizada no pré-planejamento da radioterapia conformacional do tórax, esta com dose total de 45-50 Gy em 25 frações. Para as dosagens de citocinas plasmáticas foram empregadas as técnicas de imunoabsorção enzimáticas (ELISA). Na avaliação da qualidade de vida foi aplicado o questionário Saint George´s Respiratory Questionnary traduzido e adaptado culturalmente ao Brasil. Todos estes procedimentos foram obtidos na fase pré e repedidos 3 meses após a radioterapia. Os resultados das duas fases foram comparados utilizando-se a versão exata do teste Wilcoxon e o teste de Correlação de Spearman, nível de significância p 0,05. Resultados: Entre parâmetros funcionais houve queda significativa apenas na difusão e no fluxo expiratório a 50% da capacidade vital forçada. Mesmo comportamento observou-se para citocina IL-6, já que os mesmos encontravam-se aumentados pré-RT. Não ocorreram mudanças significativas em nenhum dos domínios do questionário de qualidade de vida. As alterações tomográficas ocorreram 60,87% das pacientes na fase pós-radioterapia, em sua maioria de graus leves a moderados e não correlacionaram-se com as alterações observadas em outros parâmetros estudados. Conclusão: O aumento observado na IL-6 durante a fase pré-RT, parece ser um bom índice preditivo de alteração pulmonar. A capacidade de difusão foi a alteração mais evidente e parece ser o índice que melhor reflete as alterações pulmonares que afetam essas pacientes. Diante das discretas alterações tomográficas e funcionais observadas após a RT, é provável que para a redução observada na DLCO concorra uma combinação de fatores ao nível da membrana alvéolo-capilar. No conjunto, as alterações induzidas pela radioterapia conformacional nas pacientes estudadas foram de pequena monta, insuficientes para influenciar aspectos funcionais do pulmão e a qualidade de vida. / Radiotherapy continues to improve itself, but it may still be associated with pulmonary toxicity. Objective: To study the effects caused by local and systemic adjuvant thoracic conformal radiotherapy in women with breast cancer, without risk factors prior to the development of pulmonary alterations. Through high-resolution computed tomography, to identify the possible radiological alterations in the lung parenchyma. If positive identification occurs, correlates it with pulmonary functional parameters, its systemic effects, the dosage of inflammatory mediators IL-1, IL-6 and TNF-, and their impact on quality of life. Material and Methods: Blood samples were collected from 25 healthy patients to be used as a normal reference for IL-1, IL-6 and TNF- mediators. Due to the established strict inclusion and exclusion criteria, only 24 from the initial 157 interviewed patients were selected for this study. The evaluation of pulmonary function was comprehensive and included: Lung volume and capacity measurement through closed loop helium residual volume dilution method;Peak expiratory flow study (flow curve x volume and volume vs. time curve) and CO diffusing capacity measurement through single breath technique. High-resolution computerized tomography (16 detectors) was performed in the pre-planning phase of thoracic conformal radiotherapy where 45-50 Gy total dose was applied in 25 fractions. For cytokines plasma measurement, the enzymatic immunosorbent techniques (ELISA) were used. For quality of life assessment, the Brazil´s validated Saint George\'s Respiratory Questionnary was used. All these procedures were applied in the pre-phase and repeated three months later after radiotherapy sessions. The results of the two phases were compared using the exact version of the Wilcoxon test and Spearman correlation test with p 0.05 significance level. Results: Among the functional parameters, there were a significant decrease in dissemination and expiratory flow at 50% of forced vital capacity. The same behavior was observed for cytokine IL-6, since they were already high at pre-RT. There were no significant changes in any of the aspects of quality of life questionnaire. The tomographic alterations occurred in 60,87% of patients in the post radiotherapy phase, mostly having low to moderate degree and not correlated with the observed changes in other parameters. Conclusion: The IL-6 increase in the pre-RT phase appears to be a reasonable predictive index of pulmonary alterations. The diffusing capacity alterations were the most evident and seem to be the index that best reflects the pulmonary alterations that affect these patients. Given the discrete tomographic and functional abnormalities observed after RT, it is likely that for the observed reduction in DLCO compete a combination of factors occurring at alveolar-capillary membrane level. Overall, the conformal radiotherapy induced changes in the studied patients were not expressive, insufficient to influence the pulmonary functional aspects and the quality of life of the patients.
|
586 |
Efeito da radioterapia sobre as propriedades mecânicas, químicas e morfológicas do esmalte e da dentina de dentes permanentes - Estudo in vitro / Effect of radiotherapy on the mechanical, chemical and morphological property of the enamel and of the dentine of permanent teeth - In vitro studyGonçalves, Ligia Maria Napolitano 14 March 2012 (has links)
O presente estudo teve como objetivo avaliar, in vitro, os efeitos da radiação com cobalto-60 nas propriedades mecânicas, morfológicas e químicas do esmalte e da dentina de dentes permanentes através da: 1- microdureza longitudinal; 2- microscopia eletrônica de varredura (MEV); e 3- espectroscopia de energia dispersiva de raios X (EDX). A microdureza do esmalte e da dentina (n=12 hemissecções vestibulares) foi avaliada em três profundidades (superficial, média e profunda), antes e a cada 10 Gy de irradiação, até uma dose cumulativa de 60 Gy. A morfologia do esmalte e da dentina foi avaliada por meio de MEV (n=8 hemissecções), em 2 hemissecções vestibulares irradiadas com dose cumulativa de 30 Gy, 2 hemissecções vestibulares irradiadas com dose cumulativa de 60 Gy e 4 hemissecções palatinas não irradiadas. A composição química do esmalte e da dentina foi avaliada por meio de EDX (n=4 hemissecções), utilizando-se as mesmas hemissecções previamente submetidas à MEV (com dose cumulativa de 60 Gy de irradiação, e nas hemissecções não irradiadas). Os dados foram analisados quanto à sua distribuição e submetidos à Análise de Variância a dois critérios. Para a diferenciação das médias, empregou-se o teste de Fisher. O nível de significância adotado foi de 5%. Com relação à microdureza no esmalte, pôde-se observar que houve diferença estatisticamente significante entre os grupos (p < 0,05). A microdureza no esmalte não irradiado não apresentou diferença estatisticamente significante em comparação com a do esmalte após irradiação com doses de 40, 50 e 60 Gy (p > 0,05), e apresentou-se maior que os valores de microdureza nas doses de 10, 20 e 30 Gy (p < 0,05). Com relação à microdureza nas diferentes profundidades pôde-se observar diferença significante (p < 0,05) entre elas, observando-se no esmalte superficial seus maiores valores. Na análise morfológica do esmalte observou-se que os espécimes irradiados apresentaram alterações crescentes, em função do aumento da dose de radiação, em comparação ao esmalte não irradiado. A porção interprismática tornou-se mais evidente após as doses de 30 e 60 Gy. Em relação à microdureza da dentina, pôde-se observar que houve diferença significante entre os grupos (p < 0,05). A microdureza na dentina não irradiada não apresentou diferença estatisticamente significante em comparação com a microdureza na dose de 40 Gy (p > 0,05) e apresentou valores superiores aos observados nas doses de 10, 20, 30, 50 e 60 Gy (p < 0,05). Em relação à microdureza nas diferentes profundidades avaliadas pôde-se observar diferença significante (p < 0,05) entre elas, sendo que a dentina média apresentou seus maiores valores. Na análise morfológica da dentina observou-se a presença de fendas na estrutura dentinária, túbulos dentinários colabados/destruídos e fragmentação das fibras colágenas nas doses de 30 e 60 Gy, sendo as alterações mais intensas com aumento da dose de irradiação, para todas as regiões analisadas, em comparação à dentina não irradiada. Na análise química do esmalte e da dentina irradiados observou-se discreto aumento de oxigênio (O) e diminuição de fósforo (P) e cálcio (Ca), em comparação aos espécimes não irradiados. Os resultados permitiram concluir que a radioterapia não influenciou a microdureza do esmalte, como um todo, entretanto, quando analisou-se nas diferentes profundidades do esmalte, verificou-se um aumento da microdureza na região superficial. Na dentina, a radioterapia ocasionou diminuição da microdureza após praticamente todas as doses de radiação, em comparação à dentina não irradiada, sendo que na região da dentina média observaram-se seus menores dos valores. As alterações morfológicas das estruturas do esmalte e da dentina foram crescentes com o aumento das doses de irradiação observando-se a porção interprismática mais evidente, presença de fendas e túbulos dentinários colabados/destruídos e fragmentação progressiva das fibras colágenas. Quimicamente, após a irradiação, tanto no esmalte como na dentina, observouse um discreto aumento na porcentagem de oxigênio e redução nas porcentagens de fósforo e cálcio. / The present study had as objective to evaluate, in vitro, the effect of the radiation of 60 Cobalt (Co 60) in the mechanical, morphological and chemical properties of the enamel and of the dentine of permanent teeth by means of: 1- longitudinal microhardness; 2- scanning electron microscopy (SEM); and 3; energy dispersive X-ray spectroscopy (EDX). The microhardness of the enamel and of the dentine (n = 12 vestibular hemisections) was evaluated in three depths (superficial, medium and deep), before and at each 10 Gy of irradiation, until a total cumulative dose of 60 Gy. The morphology of the enamel and of the dentine was evaluated by means of a SEM (n = 8 hemisections), in 2 irradiated vestibular hemisections with total cumulative dose of 30 Gy, 2 irradiated vestibular hemisections with total cumulative dose of 60 Gy and 4 not irradiated palatine hemisections (control). The chemical composition of the enamel and of the dentine was evaluated by means of EDX (n = 4 hemisections), using the same hemisections previously submitted to SEM (with cumulative dose of 60 Gy of irradiation, and in the not irradiated hemisections). The data were analyzed about their distribution and submitted to the Analysis of Variance at two criteria. For the differentiation of the averages, the test of Fisher was used. The level of significance adopted was of 5%. About the longitudinal microhardness in the enamel, it was possible to be observed that there was no statistically significant difference between the groups (p < 0,05). The microhardness in the not irradiated enamel was similar to the enamel after the irradiation with doses of 40, 50 and 60 Gy (p > 0,05) and higher than the microhardness values in the doses of 10, 20, e 30 Gy (p < 0,05). About the microhardness in the different depths it was observed significant difference (p < 0,05) between them, being observed in the superficial enamel the greatest values of microhardness. In the morphological analysis of the enamel it was observed that the irradiated specimens presented growing alterations, due to the increase of the radiation dose, comparing to the not irradiated enamel. There was no difficulty in observing the prisms and the crystals after the irradiation, however the interprismatic portion became more evident after the radiation doses of 30 and 60 Gy. About the longitudinal microhardness of the dentine, it could be observed that there was significant difference between the groups (p < 0,05). The microhardness of the not irradiated dentine was not statistically significant compared to the microhardness in the dose of 40 Gy (p > 0,05) and it presented higher values to the observed ones in the doses of 10, 20, 30, 50 and 60 Gy (p < 0,05). About the relation to the microhardness in the different evaluated depths it was possible to observe significant difference (p < 0,05) among them, being that the medium dentine presented the highest values of microhardness. In the morphological analysis of the dentine it was observed the presence of cracks in the dentine structure, collapsed/destroyed dentine tubules and fragmentation of the collagen fibers in the doses of 30 and 60 Gy, being the alterations more intense with the increase of the dose of irradiation, for all the analyzed regions, comparing to the not irradiated dentine. In the chemical analysis of the irradiated enamel and the dentine it was observed the slight increase of oxygen (O) and decrease of phosphorus (P) and Calcium (Ca), comparing to the not irradiated specimens. The result allowed to be concluded that the radiotherapy occasioned the decrease of the microhardness of the enamel after the doses from 10 to 30 Gy, but in the following doses there was an increase of the microhardness, which became similar to the not irradiated enamel, being that in the superficial region it was observed the biggest increase of the microhardness. In the dentin, the radiotherapy caused decrease of the microhardness after practically all doses of radiation, comparing to the not irradiated dentine, being that in the region of the medium dentine the lowest values of microhardness were observed. The morphological alterations of the enamel and of the dentine structure were growing with the increase of the radiation doses observing the more evident interprismatic portion, presence of cracks and collapsed/destroyed dentine tubules and progressive fragmentation of collagen fibers. Chemically, after the irradiation, not only in the enamel but also in the dentin, it was observed a slight increase of percentage of the oxygen and decrease in the percentages of phosphorus and calcium.
|
587 |
Influência da irradiação com cobalto-60 nas propriedades mecânicas, químicas e morfológicas do esmalte e da dentina de dentes decíduos - estudo in vitro / Influence of cobalto-60 irradiation on the mechanical, chemical and morphological properties of enamel and dentin of primary teeth an in vitro studyMellara, Talitha de Siqueira 13 September 2011 (has links)
O objetivo do presente estudo foi avaliar, in vitro, os efeitos da irradiação com cobalto-60 (Co 60), nas propriedades do esmalte e da dentina de dentes decíduos por meio da: 1 - microdureza longitudinal; 2 - morfologia em microscopia eletrônica de varredura (MEV); e 3 - composição química em espectroscopia de energia dispersiva de raios X (EDX). No primeiro experimento foi avaliada a microdureza do esmalte e da dentina (n=12 hemissecções vestibulares) em 3 profundidade (superficial, média e profunda), antes e a cada 10 Gy de irradiação, até uma dose cumulativa total de 60 Gy. No segundo experimento foi avaliada a morfologia do esmalte e da dentina por meio de MEV (n=8 hemissecções), sendo 2 hemissecções vestibulares irradiadas com a dose cumulativa de 30 Gy, 2 hemissecções vestibulares irradiadas com a dose cumulativa de 60 Gy e 4 hemissecções palatinas não irradiadas. No terceiro experimento, identificou-se os elementos químicos do esmalte e da dentina por meio de EDX (n=4 hemissecções), utilizando-se as mesmas hemissecções previamente submetidas à MEV (com a dose cumulativa de 60 Gy de irradiação e nas hemissecções não irradiadas). No primeiro experimento a microdureza, antes e após, a irradiação, foi avaliada na mesma hemissecção dental (face vestibular). Já no segundo e terceiro experimentos, as hemissecções vestibulares foram submetidas à irradiação e as hemissecções palatinas do mesmo dente funcionaram como controle. Os dados foram analisados quanto à sua distribuição e submetidos à Análise de Variância a dois critérios. Para a diferenciação das médias, empregou-se o teste de Fisher. O nível de significância adotado foi de 5%. A microdureza longitudinal no esmalte, como um todo, variou após as diferentes doses de irradiação, aumentando significantemente após a dose de 60 Gy (p<0,05), com valores de 191,4 KH (controle); 184,7 KH (10 Gy); 184,6 KH (20 Gy); 192,9 KH (30 Gy); 198,2 KH (40 Gy); 204,1 KH (50 Gy) e 211,4 KH (60 Gy). Observou-se que no esmalte profundo foi encontrado o maior valor médio de microdureza (206,7 KH), o qual foi estatisticamente diferente (p<0,05) do valor médio das duas outras regiões avaliadas. Na microdureza longitudinal da dentina como um todo, após as diferentes doses de irradiação, observou-se diferença estatisticamente significante entre os valores de microdureza da dentina não irradiada (28,9 KH) com relação à dentina irradiada com doses de 10 Gy (23,8 KH), 20 Gy (25,6 KH), 30 Gy (24,8 KH) e 40 Gy (25,7 KH) (p<0,05). As doses 50 Gy e 60 Gy apresentaram o mesmo valor médio de microdureza (26,7 KH) e diferente da dose de 10 Gy de irradiação (p<0,05). Com 60 Gy não houve diferença estatisticamente significante quando comparado à dentina não irradiada (p>0,05). Observou-se que na dentina média foi encontrado o maior valor médio de microdureza (29,9 KH), o qual foi estatisticamente diferente (p<0,05) das outras regiões avaliadas. Na análise morfológica do esmalte observou-se que os grupos irradiados com dose de 30 Gy e 60 Gy mostraram maiores alteração da superfície do esmalte, em comparação ao esmalte não irradiado para todas as regiões analisadas, o mesmo ocorrendo na dentina. Na análise química do esmalte e da dentina irradiados, quando comparados aos espécimes não irradiados, observou-se redução de oxigênio (O) e aumento de cálcio (Ca). Conclui-se que a irradiação de dentes decíduos com Co-60 influenciou a microdureza longitudinal do esmalte e da dentina, dependendo da dose e da área irradiada. No esmalte como um todo, a microdureza aumentou com a dose cumulativa de 60 Gy, independente da área analisada. Na dentina, não houve alteração dos valores de microdureza após irradiação, independente da área analisada. Com relação à morfologia, foi observada desorganização do esmalte e da dentina, que passaram a apresentar uma superfície amorfa com aumento das doses de irradiação, com maior dificuldade de identificação dos prismas de esmalte e túbulos dentinários, respectivamente. Quimicamente observou-se redução na porcentagem de oxigênio e aumento na porcentagem de cálcio no esmalte e na dentina irradiados. / The aim of this study was to evaluate, in vitro, the effects of cobalto-60 (Co 60) irradiation on the properties of enamel and dentin of primary teeth by analysis of: 1 - longitudinal microhardness; 2 morphology by scanning electron microscopy (SEM); and 3 chemical composition by energy-dispersive X-ray spectroscopy (EDX). In the first experiment, enamel and dentin microhardness (n=12 buccal hemisections) was evaluated at 3 depths (superficial, meddle and deep), before and at each 10 Gy irradiation, up to a total cumulative dose of 60 Gy. In the second experiment, enamel and dentin morphology was evaluated by SEM (n=8 hemi-sections), being 2 buccal hemi-sections irradiated with a cumulative dose of 30 Gy, 2 buccal hemi-sections irradiated with a cumulative dose of 60 Gy and 4 non-irradiated palatal hemi-sections. In the third experiment, the chemical elements in enamel and dentin were identified by EDX (n=4 hemi-sections), using the same hemi-sections previously subjected to SEM analysis (irradiated with a cumulative dose of 60 Gy and non-irradiated). In the first experiment, microhardness was evaluated before and after irradiation in the same dental hemi-section (buccal face). In the second and third experiments, the buccal hemi-sections were irradiated and the palatal hemi-sections of the same tooth served as control. After analysis of distribution, data were subjected to two-way analysis of variance and Fishers exact test was used for differentiation of means. A significance level of 5% was adopted. Overall, longitudinal microhardness of enamel varied after the different irradiation doses, increasing significantly after the dose of 60 Gy (p<0.05), with values of 191.4 KH (control); 184.7 KH (10 Gy); 184.6 KH (20 Gy); 192.9 KH (30 Gy); 198.2 KH (40 Gy); 204.1 KH (50 Gy) and 211.4 KH (60 Gy). Deep enamel presented the highest mean value of microhardness (206.7 KH), which was significantly different (p<0.05) from the mean values of the other evaluated regions. Overall, after the different irradiation doses, there was statistically significant difference between the longitudinal microhardness values of non-irradiated dentin (28.9 KH) compared with dentin irradiated with doses of 10 Gy (23.8 KH), 20 Gy (25.6 KH), 30 Gy (24.8 KH) and 40 Gy (25.7 KH) (p<0.05). The doses of 50 Gy and 60 Gy presented the same mean value of microhardness (26.7 KH) and differed from the dose of 10 Gy irradiation (p<0.05). There was no statistically significant difference for irradiation with 60 Gy compared with non-irradiated dentin (p>0.05). The highest mean value of microhardness was obtained in the middle dentin (29.9 KH), which was significantly different (p<0.05) from the other analyzed regions. The morphological analysis of enamel and dentin revealed that the groups irradiated with doses of 30 Gy and 60 Gy presented greater surface alterations compared with non-irradiated specimens at all analyzed regions. The chemical analysis of irradiated enamel and dentin compared with non-irradiated specimens revealed a decrease of oxygen and an increase of calcium. In conclusion, irradiation of primary teeth with Co-60 influenced the longitudinal microhardness of enamel and dentin, according to the dose and irradiated region. In enamel as a whole, microhardness increased with the cumulative dose of 60 Gy, regardless of the analyzed region. In dentin, there was no change in the microhardness mean values after irradiation, regardless of the analyzed region. The analysis of morphology revealed that, the increase of the irradiation dose resulted in enamel and dentin disorganization, which presented an amorphous surface with difficulty in identifying enamel prisms and dentin tubules, respectively. The chemical analysis revealed a decrease in the percentage of oxygen and an increase in the percentage of calcium in irradiated enamel and dentin.
|
588 |
[en] METROLOGICAL EVALUATION OF THE RADIATION FIELD SIZE BY LINEAR ACCELERATORS / [pt] AVALIAÇÃO METROLÓGICA DO TAMANHO DE CAMPO IRRADIADO POR ACELERADORES LINEARESNILMARA ALMEIDA GUIMARÃES 30 August 2018 (has links)
[pt] O objetivo desta dissertação é o estudo de procedimentos para avaliação da confiabilidade metrológica do tamanho de campo irradiado (TCI) por aceleradores lineares. No contexto das recentes alterações no panorama regulamentar dos serviços de radioterapia, com a implementação da RDC número 20, em 2006, pela Agência Nacional de Vigilância Sanitária (ANVISA), foi estabelecida a compulsoriedade do uso do densitômetro óptico na verificação do TCI, como parte do controle da qualidade. Questões associadas à implementação prática dos recentes requisitos para medição do tamanho de campo irradiado e as recentes
indicações do potencial uso de filmes radiocrômicos para o controle da qualidade em radioterapia motivaram a realização do presente trabalho. Foram empregados três diferentes procedimentos para avaliação do tamanho de campo irradiado por aceleradores lineares utilizados em treze serviços de radioterapia localizados no Estado do Rio de Janeiro, utilizando filmes radiocrômicos EBT QD mais, RTQA,
densitômetro óptico DensiX tipo T52001 ou scanner de transmissão Microtek. Os resultados destacam a contribuição das fontes de incerteza de medição para cada procedimento realizado e indicam a necessidade de considerá-la na avaliação da conformidade utilizando o densitômetro óptico (DO). Devido às propriedades do filme radiocrômico RTQA, o mesmo não pode ser utilizado no procedimento de medição
com DO. Em conclusão, o uso do procedimento de medição utilizando scanner mostrou-se mais adequado para avaliação das dimensões de campos de radiação não-homogêneos. / [en] The objective of the present work is to study different procedures for metrological evaluation of the size of the radiation field emitted by linear accelerators. In the context of the recent requirements determined by the publication of the RDC number 20, in 2006, by National Agency for Sanitary Vigilance (Anvisa), the compulsory use of the optical densitometer for the measurements of the field size during quality control tests was introduced. Practical implementation issues associated with these requirements and the recent studies indicating the potential use of radiochromic films for measurements of the field size motivated the present work. Three different procedures were employed in order to evaluate the radiation field size emitted by linear accelerators used in thirteen radiotherapy services located in Rio de Janeiro, using radiochromic films EBT QD plus and RTQA, optical densitometer DensiX type T52001 or scanner
Microtek. The results indicate the contribution of the measurement uncertainty associated to each procedure performed, highlighting the importance of its consideration during tests for conformity assessment with the recently required optical densitometer. Nevertheless, the RTQA radiochromic film properties precluded its use in the procedure using optical densitometer. In conclusion, among the evaluated procedures for radiation field evaluation, the use of the scanner was the most appropriate, especially if dimensional non-homogeneities are present.
|
589 |
Estudo prospectivo randomizado do tratamento endoscópico da coloproctopatia actínica crônica hemorrágica: eletrocauterização com plasma de argônio versus bipolar / Randomized and prospective study of endoscopic treatment to hemorrhagic chronic radiation coloproctopathy: argon plasma eletrocauterization versus bipolarLenz Tolentino, Luciano Henrique [UNIFESP] 24 February 2010 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:50:11Z (GMT). No. of bitstreams: 0
Previous issue date: 2010-02-24 / Introdução: A coloproctopatia actínica crônica (CAC) é uma complicação reconhecida da radioterapia. O sangramento retal (SR) é a queixa mais comum da CAC e a melhor modalidade de tratamento endoscópico para este sintoma permanece controversa. Objetivo: Comparar a eficácia e a segurança da eletrocauterização bipolar (EB) com a eletrocauterização com plasma de argônio (EPA) no tratamento do SR secundário à CAC. Pacientes e Métodos: Foram incluídos 30 pacientes com SR ativo proveniente da CAC, randomizados em 2 grupos (15 para EB e 15 para EPA) e classificados de acordo com escore de Saunders. A potência foi de 50 W para a EB e de 40 W para a EPA. Todos foram submetidos à colonoscopia inicial para o diagnóstico da lesão e sua extensão e exclusão de outras doenças. O sucesso do tratamento foi definido pela erradicação de todas as telangiectasias. Foram consideradas falhas de tratamento, os casos nos quais sete sessões não foram suficientes para o controle do sangramento. Complicações foram divididas em três diferentes grupos: sensitivas (dor anal, dor abdominal e febre), hemorrágicas (piora do sangramento durante o tratamento e sangramento por úlceras) e anatômico-motoras (afilamento das fezes, estenoses e pseudopólipos). Resultados: A média de idade foi de 67,4 anos (variação de 33 a 82 anos) com 14 mulheres e 16 homens. Não houve diferença estatística significante entre os grupos no número de sessões (p = 0,313). Não houve diferença significativa em relação às complicações sensitivas (p = 0,245), hemorrágicas (p = 0,169) ou anatômico-motoras (p = 0,700) entre os grupos. Entretanto, a incidência total de complicações foi significativamente maior no grupo EB. Somente uma falha terapêutica foi observada em cada grupo (p = 1,000). Também não houve diferença significativa na recidiva (p = 1,000). Pacientes em uso de aspirina necessitaram de um número maior de sessões para cessação do SR (p = 0,036) e para erradicação das telangiectasias (p = 0,047). Conclusões: A EPA e a EB apresentaram semelhanças em relação à eficácia no tratamento da coloproctopatia actínica crônica hemorrágica. Contudo, a EPA é mais segura que a EB. / Introduction: Chronic radiation coloproctopathy (CRCP) is a well-recognized complication of radiotherapy. Rectal bleeding is the most common symptom of radiation injury and the optimal endoscopic treatment of bleeding due to CRCP is still controversial. Aim: To compare the efficacy and safety of bipolar eletrocauterization (BEC) and argon plasma eletrocauterization (APE) in the management of bleeding from CRCP. Methods: Thirty patients with active bleeding from telangiectasias were enrolled, randomized into two groups (15 BEC and 15 APE) and classified according to Saunders score. Power settings were 50 W for BEC and 40 W for APE. Initial treatment was performed after a complete colonoscopy to rule out synchronous lesions and follow-up was performed with flexible sigmoidoscopies. Success was defined as eradication of all telangiectasias. Failure was defined whenever more than seven sessions or other therapies were necessary for treatment of bleeding. Complications were divided into three different groups: sensory (anal pain, abdominal pain and/or fever), hemorrhagic (worsening of bleeding during treatment, bleeding from ulcers) and anatomic/motor (tapered feces, stenosis and/or pseudopolyps). Results: Mean age was 67.4 years (range 33-82), with 14 women and 16 men. There was no significant difference regarding the number of sessions in both groups (p = 0.313). There were no significant differences regarding sensory (p = 0.245) hemorrhagic (p = 0.169) or anatomic/motor (p = 0.700) complications between both groups. However, the overall complication rate was significantly higher in EB group (p = 0.020). Only one failure was observed in each group (p = 1.000). There was also no significant difference regarding relapse (p = 1.000) Conclusions: BEC and APE are equally effective in patients with bleeding telangiectasias from CRCP. Nevertheless, APE is safer than EB. / TEDE / BV UNIFESP: Teses e dissertações
|
590 |
Cofilina-1 (CFL-1) correlaciona-se à sobrevida mediana em pacientes com carcinoma de pulmão não de pequenas células tratados com radioterapiaLeal, Matheus Hermes January 2016 (has links)
Base teórica: O câncer de pulmão é uma doença com alta incidência e mortalidade, cujo prognóstico permanece discreto apesar do melhor entendimento da doença nas últimas décadas. A radioterapia tem papel terapêutico em todos os estágios da doença. A expressão da cofilina-1, uma proteína relacionada à mobilidade celular, determinou maior radiossensibilidade a células de adenocarcinoma brônquico em estudos in vitro, porém pior sobrevida em estádios iniciais Objetivo: Avaliar se a expressão da cofilina-1 interfere na sobrevida e no controle local em pacientes com câncer de pulmão submetidos a tratamento com radioterapia definitiva Métodos: Foram avaliados pacientes com câncer de pulmão não pequenas células, com estádios I–IV, que receberam radioterapia exclusiva ou combinada com quimioterapia, dirigida à neoplasia brônquica, na unidade de radioterapia do HCPA, nos anos de 2009 a 2015. Todos os pacientes tiveram a expressão de cofilina-1 aferida e foram distribuídos conforme os níveis de expressão de cofilina-1 utilizando-se de protocolo específico. Os prontuários foram avaliados retrospectivamente para calcular a sobrevida mediana. A progressão foi verificada através de avaliação de tomografias de tórax de controle. Resultados: Foram avaliados 45 pacientes neste estudo. A sobrevida mediana de todos os pacientes foi de 11,3 meses e a sobrevida global em 5 anos de 17,3%. Pacientes com expressão média ou alta de cofilina-1 tiveram maior mortalidade quando comparados com pacientes com baixa expressão (respectivamente, HR 1,628, IC95 1,137-8,287 e HR 1,59 IC95 1,105-7,342). Não houve diferença significantemente estatística entre controle local e expressão de cofilina-1. Conclusão: A expressão de cofilina-1 está associada à sobrevida em pacientes com carcinoma brônquico tratados com radioterapia e existe uma tendência a melhor controle local com baixa expressão. Nossos resultados sugerem um novo campo a ser explorado no manejo do carcinoma de pulmão localmente avançado, utilizando-se dos níveis de cofilina-1. / Background: Lung cancer is a disease with high incidence and mortality, whose prognosis remains poor despite a better understanding of the disease in the last decades. Radiotherapy plays a therapeutic role in all stages of disease. The expression of cofilin-1, a protein related to cellular mobility, determined greater radiosensitivity to lung adenocarcinoma cells in in vitro studies, but worse survival at initial stages. Objective: To evaluate if the expression of cofilin-1 modified survival and local control in lung cancer patients submitted to definitive treatment with radiotherapy. Methods: Patients with non-small cell lung cancer with stage IIV who received radiotherapy alone or combined with chemotherapy for lung cancer at the HCPA radiotherapy unit from 2009 to 2015 were evaluated. All patients had the expression of measured cofilin-1 evaluated and were distributed by cofilin-1 expression according to specific protocol. The medical records were retrospectively evaluated to estimate median survival. The progression was verified through evaluation of control chest tomography. Results: 45 patients were assessed in this study. The median survival of all patients was 11.3 months and the 5-year overall survival was 17.3%. Patients with medium or high expression of cofilin-1 had higher mortality rates when compared to patients with low expression (HR, 1,628, CI95, 1,137-8,287 and HR, 1.59, CI95, 1,105-7,342). There was no statistically significant difference between local control and cofilin-1 expression. Conclusion: cofilin-1 expression is associated with survival in patients with lung cancer treated with radiotherapy and there is a tendency for better local control with low CFL1 expression. Our results suggest a new field to be explored in the management of locally advanced lung carcinoma, using cofilin-1 expression levels.
|
Page generated in 0.0762 seconds