• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1586
  • 26
  • 23
  • 21
  • 21
  • 21
  • 11
  • 10
  • 7
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 1642
  • 1642
  • 806
  • 726
  • 360
  • 358
  • 213
  • 207
  • 200
  • 169
  • 162
  • 160
  • 153
  • 151
  • 150
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
561

Avaliação dos efeitos do posicionamento relacionados à opacificação pulmonar gravitacional dependente em cães (Canis familiaris) através da tomografia computadorizada / Evaluation of position’s effects related to gravitacional pulmonary dependent densities in dogs (Canis familiaris) by computed tomography

Elisangela Aneli 06 June 2005 (has links)
A tomografia computadorizada (TC) é o método de diagnóstico de eleição para a avaliação dos campos pulmonares. Porém, a atelectasia pulmonar ou opacificação pulmonar dependente da gravidade, observada em indivíduos submetidos à anestesia ou a longos períodos de decúbito, pode aumentar o risco de se obscurecer lesões pulmonares, como as metástases. O objetivo deste trabalho foi comparar, através do uso da TC, o efeito dos decúbitos dorsal e esternal na formação de opacificação pulmonar gravitacional dependente em cães anestesiados. Foram utilizados dezesseis cães adultos (Canis familiaris), da raça Rottweiller, clinicamente normais. Estes animais foram divididos em quatro grupos, submetidos a dois exames tomográficos, em decúbito dorsal e em decúbito esternal, em diferentes tempos anestésicos: imediatamente após a indução anestésica, 20 minutos após a indução anestésica, 40 minutos e 60 minutos após a indução anestésica. Foram realizados quatro cortes transversais, em pontos pré-determinados do tórax. Foi determinada a densidade pulmonar média setorial, a densidade em unidades de Hounsfield (HU) e área em cm² nas áreas de opacificação pulmonar gravitacional dependente formadas. A densidade média setorial demonstrou que o decúbito dorsal apresentou significante gradiente de atenuação das porções não dependentes para as porções dependentes do tórax, enquanto que no decúbito esternal tal comportamento não foi observado. Com relação às áreas de opacificação pulmonar gravitacional dependente, estas foram observadas em 43,75% dos animais em decúbito dorsal e em 18,75% dos cães em decúbito esternal, com atenuações de –43,95 a –361,94 HU para ambos os decúbitos, área mínima de 0,03 e máxima de 1,55 cm² no decúbito dorsal, e 0,24 a 0,70 cm² no decúbito esternal / Computed tomography (CT) is a diagnostic method of election to the lungs evaluation. However, the pulmonary atelectasis or gravitacional dependent pulmonary densities, wich is observed during general anesthesia or long-term of recumbency, could increase the risk of obscuring pulmonary lesions, such metastasis. The aim of this study was to compare the recumbency effect´s (supine and prone), by CT, on the formation of pulmonary densities in anesthetized dogs. Sixteen healthy Rottweiler dogs (Canis familiaris) were used. These dogs were divided into four groups, wich performed dorsal and prone CT exams each, with differents periods of anesthesia: immediately after induction, 20 minutes after induction, 40 minutes and 60 minutes after induction. There were performed four transverse CT scans, in differents sites of the chest. There were determined mean lung density (sector method), pulmonary densities in Hounsfield units (HU) and area in cm² of dense areas in dependent lung regions. Mean lung density was demonstrated that the supine recumbency had a significant density gradient from non-dependent to dependent lung regions, and the prone position hadn´t any density gradient. Dense areas were observed in 43,75% of dogs in supine recumbency and in 18,75% of dogs in prone recumbency. Atenuation was between – 43,47 to – 361,94 HU in both recumbencies. Area was between 0,03 to 1,55 cm² in supine position, and 0,24 to 0,70 cm² in prone position
562

Relação da gordura visceral abdominal e doença coronária avaliada pela tomografia computadorizada de múltiplos detectores / Relation between visceral fat and coronary artery disease evaluated by multidetector computed tomography

Mateus Diniz Marques 17 June 2009 (has links)
INTRODUÇÃO: A gordura visceral abdominal tem sido associada com os fatores de risco cardiovasculares e com a doença arterial coronária (DAC). A maior parte dos estudos delineados para avaliar o risco atribuído à distribuição da gordura corporal utilizaram as medidas antropométricas para estimar a gordura visceral. Entretanto, quando comparada com as medidas antropométricas tradicionais (circunferência do quadril e relação das medidas da cintura e quadril), a gordura visceral avaliada pela tomografia computadorizada (TC) foi mais intensamente associada aos fatores de risco para DAC. A angiografia por TC com múltiplos detectores é um método diagnóstico em ascensão, permitindo a detecção de DAC obstrutiva e não obstrutiva, acrescentando informação para a estratificação de risco cardiovascular. O objetivo desse estudo foi avaliar a associação entre DAC e as medidas de adiposidade por métodos clínicos e tomográficos. MÉTODOS: Nós avaliamos prospectivamente 125 indivíduos consecutivos (57% eram homens, idade média de 56 ± 12 anos) referenciados para realizar angiografia coronária por TC. As variáveis clínicas e laboratoriais foram determinadas e tomografias cardíacas e abdominais foram realizadas em um tomógrafo com 64 fileiras de detectores. A DAC foi definida pela presença de qualquer placa coronária, calcificada ou não, identificada pela angiografia por TC. As artérias coronárias foram classificadas de acordo com a presença ou não de estenoses significativas (obstrução do diâmetro luminal 50%). As calcificações coronárias foram determinadas pelo escore de cálcio. As medidas de gordura visceral e subcutâneas foram realizadas em diferentes níveis do espaço intervertebral. RESULTADOS: A angiografia por TC detectou DAC em 70 participantes (56%) e nenhuma associação foi encontrada com as medidas antropométricas usuais (circunferências de cintura e quadril e índice de massa corpórea). Entretanto, as medidas das áreas de gordura visceral abdominal (GVA) foram significativamente associadas ao diagnóstico de DAC. As médias das áreas de GVA no espaço intervertebral L1-T12 (GVA L1-T12) e L4-L5 (GVA L4-L5) foram 151,2 cm2 e 167,2 cm2, respectivamente. Valores de GVA L1-T12 145 cm2 apresentaram odds ratio de 2,85 (1,3 6,26, IC95%) para o diagnóstico de DAC e a GVA L4-L5 150 cm2 apresentou odds ratio de 2,87 (1,31 6,3, IC 95%) para DAC. As medidas de adiposidade não mostraram associação com o grau de estenose coronária, nem com a presença de calcificações coronárias identificadas pelo escore de cálcio. A análise multivariada determinou a idade e a GVAL1-T12 como as únicas variáveis independentemente associadas ao diagnóstico de DAC. CONCLUSÃO: A gordura visceral avaliada pela TC é um marcador independente de DAC diagnosticada pela angiografia coronária por TC. A avaliação da gordura visceral pela TC em diferentes sítios abdominais foi fortemente associada à DAC, e não se associou às tradicionais variáveis antropométricas e clínicas utilizadas para estimar o risco cardiovascular. A utilização das medidas de adiposidade pela TC na prática clínica pode agregar valor à estratificação de risco da DAC / INTRODUCTION: Visceral abdominal fat has been associated with cardiovascular risk factors and coronary artery disease (CAD). Visceral fat is frequently estimated using anthropometric measurements, but computed tomography (CT) studies have shown stronger association with CAD risk than anthropometric variables (waist circumference, waist-to-hip ratio). CT angiography is an emerging technology allowing detection of both obstructive and nonobstructive CAD adding information to clinical risk stratification. The aim of this study was to evaluate the association between CAD and adiposity measurements assessed clinically and by CT. METHODS: We prospectively evaluated 125 consecutive subjects (57% men, age 56.0 ± 12 years) referred to perform CT angiography. Clinical and laboratory data were determined. Cardiac CT and abdominal CT were performed in a 64- slice scanner. CAD was defined as the presence of any plaque detected by CT angiography and stenosis were graded as significant (greater than 50% of luminal narrowing) or nonsiginificant (less than 50%). The presence of coronary calcification was determined by calcium score. Visceral and subcutaneous adiposity measurements were determined at different intervertebral levels. RESULTS: CT angiography detected CAD in 70 (56%) subjects, and no association was found with usual anthropometric adiposity measurements. Nevertheless CT visceral fat area (VFA) was significantly associated to CAD. The mean VFA at the intervertebral locations T12-L1 (VFA L1-T12) and L4-L5 (VFA L4-L5) were 151.2 cm2 and 167.2 cm2, respectively. VFA L1-T12 values 145 cm2 had an odds ratio of 2.85 (95% CI - 1.30 6.26) to CAD and VFA L4-L5 150 cm2 had a 2.87-fold (95% CI - 1.31-6.30) CAD risk. Adiposity measurement was not related to stenosis severity and neither to the presence of coronary calcification. The multivariate analysis determined age and VFA L1-T12 as the only independent variables associated to CAD. CONCLUSION: Visceral fat as assessed by CT angiography is an independent marker of CAD. VFA in different abdominal sites was strongly related to CAD but this relation was not found using anthropometric measurements and clinical variables. The use of these CT adiposity measurements in the clinical practice may improve the risk stratification to CAD
563

Investigação de propriedades de filmes finos de Al2O3 para aplicação em dispositivos eletrônicos

Boratto, Miguel Henrique [UNESP] 10 February 2014 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-10Bitstream added on 2014-06-13T19:29:25Z : No. of bitstreams: 1 boratto_mh_me_bauru.pdf: 1198664 bytes, checksum: 4485a5159d7fb76191066a7ac2e905ce (MD5) / O escopo deste trabalho é a obtenção de filmes finos de óxido de alumínio (alumina) através da evaporação resitiva de alumínio, seguido da oxidação térmica em atmosfera adequada (ar ou rica em O2), com varaiação do tempo e da temperatura do tratamento térmico. A investigação deste material tem por finalidade sua utilização como camada isolante em transistores de efeito de campo, mais especificamente do tipo metal-óxido-semicondutor (MOSTFET), visando a diminuição da corrente de fuga no gate e aumento do controle de corrente no canal de condução. Além de se tratar de dipositivo transparente, que permite a interação com luz. A análise das propriedades ópticas e estruturais dos filmes investigados mostra que na temperatura de 550ºC ocorre uma completa oxidação do material, a qual é acelerada em atmosfera de oxigênio. Valores de resistividade elétrica concordam com a tendência de oxidação revelada pelos dados de Difração de Raios X (DRX). Além disso, resultados de espectroscopia no infravermelho (FTIR) e Raman, em bom acordo com resultados de DRX, apresentam-se estrutura y-Al2O3. Amostras de alumina depositadas sobre substrato de vidro sodalime apresentam silício cristalino na interface com o Al2O3 advindo do substrato, enquanto amostras de Al2O3 sobre SnO2 não apresentaram esse material. A heterojunção entre SnO2:4at%Sb e Al2O3 foi caracterizada por DRX, Microscopia eletrônica de varredura (MEV) e Microscopia Confocal, que mostraram alta rugosidade do filme isolante sobre o semicondutor, e um provável processo de difusão entre as camadas isolante e semicondutora, em concordância com resultados de corrente x voltage (IxV), obtidos a partir da construção de um dispositivo simples, com contatos de Sn, ao qual foram submetidos dispositivos com diferentes números de camadas isolantes... / The goal of this work is is to obtain aluminum oxide (alumina) thin films deposited by resistive evaporation of Al, followed by thermal oxidation in proper atmosphere (air or O2-rich), with varying time and temperature of thermal annealing. The investigation of this material of this material aims using this material for application as insulating layer in field effect transistors, specifically metal-oxide-semiconductor (MOSFET), seeking for low leakage current and efficient current control in the conduction channel. Besides, it is a transparent device, which allows interaction with light. Analysis of optical and structural properties of investigated films reveals that temperature of 550ºC is responsable for fair oxidation, which is accelerated in oxygen-rich atmosphere. Results of electrical resistivity agree with the oxidation, which is accelerated in oxygen-rich atmosphere. Results of electrical resistivity agree with the oxidation tendency found in the X-ray diffraction data (XRD). Moreover, results of infrared spectroscopy (FTIR) and Raman show the presence of y-Al2O3, also found in XRD data. Alumina samples deposited on soda-line glass substrates leads to the presence of crystalline Si, coming from the substrate leads to the presence of crystalline Si, coming from the substrate, whereas... (Complete abstract click electronic access below)
564

Novos polímeros de coordenação e complexos moleculares envolvendo seleninatos e selenonatos / New coordination polymers and molecular complexes involving seleninatos and selenonates

Vicenti, Juliano Rosa de Menezes 03 July 2012 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / In this work thirteen new compounds were synthesized and characterized using the two acids, phenylseleninic (1) and 4-bromophenylseleninic (2) as ligands precursors. Reactions were carried out using ammonium salts of seleninic acids and salts of metals MnII, CoII, NiII, PbII and AgI. Suitable single crystals for X-ray diffraction were obtained from filtrated of the reactions or by dissolving the precipitates in proper solvents. From all compounds, seven are coordination polymers: phyllo-poly- {[Mn(OH2)6][Mn2-m-(O2SePh)6]} (3), phyllo-poly-{[Mn(OH2)6][Mn2-m-(O2SeC6H4Br)6]} (4), phyllo-poly-[Co-m-(O2SePh)2(OH2)2] (5), phyllo-poly-[Ni-m-(O2SePh)2(OH2)2] (6), phyllo-poly-[Co-m-(O2SeC6H4Br)2(OH2)2] (9), phyllo-poly-[Pb-m-(O2SePh)2] (12) e phyllo-poly-[Ag-m-(O2SePh)] (15); the other six compounds are molecular: [Co(OH2)6](O3SePh)2 (7), [Ni(OH2)6](O3SePh)2 (8), [Co(OH2)2(NH3)4](O2SeC6H4Br)2×2H2O (10), [Ni(OH2)2(NH3)2(O2SePh)2] (11), [Ag(PPh3)2(O2SePh)]×(CH3)2C(=O) (14) e [Ag6-m-(SeC6H4Br)6(PPh3)5] (16). The products were characterized by infrared spectroscopy, powder X-ray diffraction, single crystal X-ray diffraction, elemental analysis and thermogravimetry. / Neste trabalho treze novos compostos foram sintetizados e caracterizados a partir dos pré-ligantes ácido fenilselenínico (1) e ácido 4-bromofenilselenínico (2). As reações foram realizadas empregando-se sais de amônio dos ácidos selenínicos e sais dos metais MnII, CoII, NiII, PbII e AgI. Monocristais apropriados para difração de raios-X foram obtidos nos filtrados das reações ou a partir da dissolução dos precipitados em solventes adequados. Dos compostos obtidos, sete são polímeros de coordenação: phyllo-poli-{[Mn(OH2)6][Mn2-m-(O2SePh)6]} (3), phyllo-poli- {[Mn(OH2)6][Mn2-m-(O2SeC6H4Br)6]} (4), phyllo-poli-[Co-m-(O2SePh)2(OH2)2] (5), phyllo-poli-[Ni-m-(O2SePh)2(OH2)2] (6), phyllo-poli-[Co-m-(O2SeC6H4Br)2(OH2)2] (9), phyllo-poli-[Pb-m-(O2SePh)2] (12) e phyllo-poli-[Ag-m-(O2SePh)] (15); os seis compostos restantes são moleculares: [Co(OH2)6](O3SePh)2 (7), [Ni(OH2)6](O3SePh)2 (8), [Co(OH2)2(NH3)4](O2SeC6H4Br)2×2H2O (10), [Ni(OH2)2(NH3)2(O2SePh)2] (11), [Ag(PPh3)2(O2SePh)]×(CH3)2C(=O) (14) e [Ag6-m- (SeC6H4Br)6(PPh3)5] (16). Os produtos foram caracterizados por espectroscopia de infravermelho, difração de raios-X em pó, difração de raios-X em monocristal, análise elementar e termogravimetria.
565

Efeito do envelhecimento mecânico e degradação hidrotérmica sobre a microestrutura, propriedades ópticas e mecânicas da zircônia monolítica indicada para próteses sem cobertura de porcelana / Effects of mechanical and hydrothermal degradation on the microstructure, optical and mechanical properties of high translucency zirconia for monolithic restorations

Mariscal Muñoz, Eduardo [UNESP] 13 March 2017 (has links)
Submitted by Eduardo Mariscal Munoz (mariscaleduardo@live.com) on 2017-05-02T16:49:25Z No. of bitstreams: 1 Tese final.pdf: 7375060 bytes, checksum: 3764fd87fe0793316c094df00347b2c4 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-05-03T20:34:18Z (GMT) No. of bitstreams: 1 mariscalmunoz_e_dr_arafo.pdf: 7375060 bytes, checksum: 3764fd87fe0793316c094df00347b2c4 (MD5) / Made available in DSpace on 2017-05-03T20:34:18Z (GMT). No. of bitstreams: 1 mariscalmunoz_e_dr_arafo.pdf: 7375060 bytes, checksum: 3764fd87fe0793316c094df00347b2c4 (MD5) Previous issue date: 2017-03-13 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A zircônia monolítica (com maior translucidez) dispensa a cobertura de porcelana, mas existem dúvidas quanto a seu comportamento frente degradação a baixa temperatura (LTD) devido à exposição direta em meio úmido e estresse mecânico. Este estudo avaliou os efeitos do envelhecimento artificial sobre a microestrutura, a resistência à flexão, as propriedades ópticas, a resistência à fadiga e ao desgaste de duas zircônias monolíticas: sendo uma para dentes posteriores (Prettau Zirkonzahn – ZrP), e a outra para anteriores (Prettau Anterior Zirkonzahn – ZrA) e uma zircônia para infraestrutura (Zirkon Transluzent – Zirkhonzan- ZrI). Espécimes com 12 mm de diâmetro e 1,2 mm de espessura foram submetidos aos seguintes envelhecimentos artificiais: ciclagem mecânica (M); envelhecimento hidrotérmico (H); associação entre ciclagem mecânica e envelhecimento hidrotérmico (M+H); e sem tratamento (controle). A microestrutura, morfologia superficial e tamanho de grãos foi avaliada por microscopia eletrônica de varredura (MEV); a rugosidade (Sa) por microscopia confocal a laser e a composição das fases cristalinas por difração de raios-X (DRX). As propriedades ópticas de refletância média, opacidade (%), parâmetro de translucidez e a soma de dispersão de luz (%) foram calculadas desde medições de luz refletida nos comprimentos de onda de 400 – 740 nm. A caracterização mecânica foi composta por ensaios de resistência à flexão biaxial e limite de fadiga, e resistência ao desgaste por compressão com deslizamento comparando ZrP, ZrA e porcelana de cobertura (VM9, VITA). As zircônias apresentaram diferentes tamanhos de grãos (ZrI<ZrP<ZrA) e alterações superficiais. A rugosidade não foi alterada pelos tratamentos. Em ZrI, a fase tetragonal diminuiu após os tratamentos H e M+H e aumentaram as fases cúbica e monoclínica. Na ZrP, os tratamentos H e M+H diminuíram a fase tetragonal do material, já a monoclínica e cubica aumentaram. Na ZrA a fase monoclínica não ocorreu após qualquer tratamento. As propriedades ópticas foram parcialmente afetadas pelos envelhecimentos. A refletância media foi reduzida após o tratamento M+H nos três materiais, o tratamento M diminuiu a refletância apenas de ZrA. A opacidade aumentou em ZrP e ZrA somente após os tratamentos M e M+H. A translucidez diminuiu em ZrP e ZrA após os tratamentos M e M+H. A soma de absorção e dispersão diminuiu para ZrP após a M+H e ZrA após M e M+H. A resistência a flexão biaxial foi maior para ZrI e ZrP, enquanto ZrA foi afetada após os tratamentos M e M+H. A resistência a fadiga aumentou em ZrI após o tratamento H, enquanto em ZrP aumentou após tratamentos H e M. ZrA não foi susceptível a nenhum dos tratamentos. Os materiais mostraram dessemelhante resistência ao desgaste (porcelana>ZrA>ZrP). Em conclusão, o conjunto dos testes revelam que ZrA não foi susceptível ao tratamento H que simula LTD, mas foi menos resistente que ZrI e ZrP recomendando cautela na sua indicação. / Porcelain veneer covering is not necessary for monolithic high translucency zirconia, and given its direct exposition to humidity and mechanic stress, there exists some concerning about its behavior against to low temperature degradation (LTD). This study evaluated the effects of artificially induced aging on microstructure, flexure resistance, optical properties and fatigue and wear resistance, of two monolithic zirconias, one for anterior teeth restorations (Prettau Anterior Zirkonzahn – ZrA), one for posterior teeth (Prettau Zirkonzahn – ZrP) and another for core fabrication (Zirkon Transluzent – Zirkhonzan- ZrI). Specimens with 12 mm of diameter and 1.2 mm of thickness were submitted to one of the following artificial aging methods; mechanical cycling (M), hydrothermal (H), mechanical cycling and hydrothermal combination (M+H) and no treatment (controle). Superficial morphology, microstructure and grain size were assessed by SEM analysis, changes in roughness (Sa) were measured by laser confocal microscopy and crystalline phase content was quantified by X-ray diffraction (XRD). Optical properties of mean reflectance, opacity (%), translucency parameter and scattering/absorption sum (%) were obtained since reflected light measurement from 400 - 700 nm wavelength. Mechanical characterization was made by biaxial flexure assay and staircase approach fatigue test. Wear resistance was assessed in ZrP, ZrA through a compression/sliding assay comparing to veneering porcelain (VITA VM9). Zirconias showed different grain size (ZrI<ZrP<ZrA) and surface alterations. Aging treatments did not promote alterations in roughness. ZrI tetragonal phase decreased after H and M+H treatments and cubic and monoclinic phases augmented. H and M+H treatments diminished ZrP tetragonal phase and cubic and monoclinic phases increased. In ZrA, monoclinic phase did not appear in any condition. Optical properties were partially affected by aging. Mean reflectance decreased after M+H treatment for the three materials, and M treatment decreased only ZrA reflectance. Opacity in ZrP and ZrA augmented only after M and M+H treatments. Translucency decreased in ZrP and ZrA after M and M+H treatments. Scattering absorption sum diminished for ZrP after M+H and in ZrA when M and M+H were applied. Biaxial flexure resistance was higher in ZrI and ZrP, while in ZrA, this property was affected only by M and M+H. Fatigue resistance augmented in ZrI after H treatment and ZrP after H and M treatments. ZrA fatigue resistance was not susceptible to any treatment. Materials showed different wear resistance capacity (porcelain>ZrA>ZrP). In conclusion, our tests revealed that ZrA was not susceptible to LTD, however were less resistant than ZrI and ZrP suggesting precaution in its indication. / FAPESP: 2013/21235-6 / FAPESP: 2013/22539-9
566

Etapas de beneficiamento na qualidade física, fisiológica e sanitária de sementes de Brachiaria brizantha / Processing phases in the physical, physiological and sanitary quality of Brachiaria brizantha seeds

Jeromini, Tatiane Sanches [UNESP] 28 July 2017 (has links)
Submitted by TATIANE SANCHES JEROMINI null (tatiane_jeromini@hotmail.com) on 2017-08-24T11:31:07Z No. of bitstreams: 1 Dissertação_Tatiane_Sanches_Jeromini.docx.pdf: 1280342 bytes, checksum: 767aec80431e07f5957d612bb0e92349 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-08-25T13:27:36Z (GMT) No. of bitstreams: 1 jeromini_ts_me_jabo.pdf: 1280342 bytes, checksum: 767aec80431e07f5957d612bb0e92349 (MD5) / Made available in DSpace on 2017-08-25T13:27:36Z (GMT). No. of bitstreams: 1 jeromini_ts_me_jabo.pdf: 1280342 bytes, checksum: 767aec80431e07f5957d612bb0e92349 (MD5) Previous issue date: 2017-07-28 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / As sementes de gramíneas forrageiras recebidas pelas empresas após a colheita contêm impurezas que comprometem a qualidade dos lotes e que podem ser removidas por máquinas de beneficiamento. O objetivo deste trabalho foi avaliar o efeito das diferentes etapas do beneficiamento sobre a qualidade física, fisiológica e sanitária de sementes de Brachiaria brizantha cv. Marandú. As sementes foram amostradas antes do beneficiamento e após a saída da máquina de ar e peneiras (descarga das peneiras superior, intermediária e fundo), primeira (deriva, descarga superior e intermediária) e segunda mesa gravitacional (descarga superior e intermediária e inferior). As sementes foram avaliadas quanto ao teor de água, pureza, peso de mil sementes, raios X, germinação, testes de vigor pela primeira contagem, envelhecimento acelerado, emergência de plântulas em campo, índice de velocidade de emergência, análise computadorizada de imagens (índice de crescimento, uniformidade e vigor) e qualidade sanitária. O beneficiamento de sementes de B. brizantha cv. Marandú por meio da máquina de ar e peneiras e da primeira mesa gravitacional aprimorou a qualidade física e fisiológica do lote. Somente o material procedente da descarga intermediária da primeira mesa gravitacional apresentou germinação e pureza suficiente para ser comercializado como semente. O beneficiamento não foi capaz de melhorar a qualidade sanitária das sementes B. brizantha cv. Marandú. A análise computadorizada de plântulas não foi eficiente para a avaliação da qualidade fisiológica de sementes de B. brizantha. / Forage grasses seeds received by companies after harvesting contain impurities that compromise lots quality and can be removed by processing machines. The aim of this project was to evaluate the effect of the different processing phases on physic, physiological and sanitary quality of Brachiaria brizantha cv. Marandú seeds. The seeds were sampled before processing and after leaving the air and screen machine (upper and intermediary screens and bottom); first gravity table (drift, upper and intermediate spouts); second gravity table (upper, intermediate, and lower spouts). Seeds were evaluated as to water content, purity, 1000 seeds weight, X - rays, germination, vigor tests of first count of germination, accelerated aging, seedling emergence in the field, speed of emergence index, computerized image analysis (growth index, uniformity and vigor) and sanitary quality. The processing of B. brizantha cv. Marandu seeds with the air and screen machine first gravity table improved the physical and physiological quality of the lot. Only the material of intermediate discharge of the first gravity table presented purity and germination enough to be marketed. The processing is not able to improve the sanitary quality of marketable seeds of B. brizantha cv. Marandu. The computerized analysis of seedlings was not efficient for the evaluation of the physiological quality of B. brizantha seeds. / CNPq: 134511/2015-8
567

Estudos estruturais com a BnSP-7 nativa e recombinante: uma fosfolipase A2 homóloga do veneno de Bothrops pauloensis / Structural studies with native and recombinant BnSP-7: a phospholipase A2-like from Bothrops pauloensis venom

Lima, Lino Fernando Gomes de [UNESP] 22 August 2017 (has links)
Submitted by LINO FERNANDO GOMES DE LIMA (linofernando@ibb.unesp.br) on 2017-10-12T13:07:03Z No. of bitstreams: 1 TESE_DOUTORADO_LINO_FINAL_CORREÇÕES_BANCA.pdf: 7596280 bytes, checksum: daa6099c657cb8875c1dc696f2b54217 (MD5) / Approved for entry into archive by Monique Sasaki (sayumi_sasaki@hotmail.com) on 2017-10-18T16:34:35Z (GMT) No. of bitstreams: 1 lima_lfg_dr_bot.pdf: 7596280 bytes, checksum: daa6099c657cb8875c1dc696f2b54217 (MD5) / Made available in DSpace on 2017-10-18T16:34:35Z (GMT). No. of bitstreams: 1 lima_lfg_dr_bot.pdf: 7596280 bytes, checksum: daa6099c657cb8875c1dc696f2b54217 (MD5) Previous issue date: 2017-08-22 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / As fosfolipases A2-like (PLA2s-like) estão entre os principais componentes de peçonhas de serpentes envolvidas no processo de envenenamento, particularmente em serpentes do gênero Bothrops. Essas toxinas promovem efeitos miotóxicos que não são neutralizados pela soroterapia convencional e podem levar até a perda do membro afetado. Os estudos estruturais, em especial a técnica de cristalografia, são uma ferramenta poderosa na compreensão da relação estrutura-função de moléculas. O presente trabalho teve por objetivo estudar estruturalmente por diferentes técnicas biofísicas (dicroísmo circular, espalhamento de luz dinâmico, Espectroscopia de fluorescência, termoforese de microescala, cristalização, coleta de dados de difração de raios-X, elucidação e análise estrutural) uma Lys-49-PLA2 da peçonha de Bothrops pauloensis, denominada BnSP-7, em suas formas nativa e complexadas com o ácido cinâmico e seus derivados, ácido cafeico e ácido p-cumárico. Adicionalmente, a mesma proteína foi estudada em sua forma recombinante. A ORF referente à BnSP-7 foi inserida no vetor a partir dos sítios de restrição EcoRI (3’ DNA) e NotI (5’ DNA). Esse inserto foi inserido em um vetor pPicZA, transformado em Pichia pastoris e induzida a expressão. Após purificação da proteína expressa, foram realizados ensaios de cristalização. Nas estruturas da BnSP-7 obtida a partir do veneno de B. pauloensis, foram encontrados ligantes na região MDoS nos três complexos elucidados, bem como a análise dos túneis revelou diferenças nas cargas positivas da BnSP-7 em comparação com outras miotoxinas. Os experimentos de termoferese revelaram que os três ligantes se ligaram à BnSP-7 com afinidades variando de 20-300 µM, sendo que a maior afinidade foi observada para o ácido cafeico, seguido pelo ácido p-cumárico e pelo ácido cinâmico. Estes dados estão de acordo com o número de interações eletrostáticas observadas nas estruturas cristalográficas. Esses resultados reforçam a importância da região MDoS no mecanismo de ação miotóxica dessas proteínas, além de fornecer dados estruturais para o desenvolvimento de inibidores mais efetivos contra os efeitos locais do acidente ofídico, não eficientemente tratado pela soroterapia convencional. / Phospholipases A2-like (PLA2-like) toxins are among the main components of snake venoms involved in the envenomation process, particularly in snakes from Bothrops genus. These toxins promote myotoxic effects that aren't neutralized by conventional serum therapy and may lead to loss of the affected limb. Structural studies, especially the crystallography technique, are powerful tools for understanding of the structure-function relationship of molecules. The aim of this work was structurally study by different biophysical techniques (circular dichroism, dynamic light scattering, fluorescence spectroscopy, microscale thermophoresis, crystallization, X-ray diffraction data, elucidation and structural analysis) a Lys-49-PLA2 of Bothrops pauloensis venom, named BnSP-7, in native form and complexed to cinnamic acid and its derivatives caffeic acid and p-coumaric acid. BnSP-7 ORF was inserted into the vector EcoRI (3 'DNA) and NotI (5' DNA) restriction sites. This insert was inserted into pPicZA vector, transformed into Pichia pastoris and induced the expression. After purification of the expressed protein, crystallization assays were performed. BnSP-7 structures complexed to the ligands were performed using B. pauloensis venom which these molecules were found interacting to MDoS region for the three complexes. Furthermore, tunnel analyses revealed differences in the positive charges of BnSP-7 compared to other myotoxins which may be related to the specificity of this toxin. Thermophesis experiments revealed that all three ligands bound to BnSP-7 with affinities ranging from 20-300 μM, in which the highest affinity was observed for caffeic acid, followed by the p-coumaric acid and by cinnamic acid. These data are in agreement with the observed number of electrostatic interactions observed in crystallographic structures. These results consolidate the importance of the MDoS region as a mechanism of myotoxic action of these proteins, in addition to providing structural data for the more effective inhibitors development against the local effects of the snakebite, not efficiently neutralized by conventional serum therapy. / CNPq: 140501/2014-2
568

Avaliação da desmineralização dentária por meio da densidade óptica e difração de raio X em dentes submetidos a clareamento exógeno

Ruviaro, Gisele Leite [UNESP] 25 July 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-07-25Bitstream added on 2014-06-13T19:58:57Z : No. of bitstreams: 1 ruviaro_gl_me_sjc.pdf: 435847 bytes, checksum: 066c40648d91cbe5f6acd4b140e67936 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / É objetivo neste trabalho avaliar a possibilidade da desmineralização dentária em 50 dentes pré-molares humanos quando submetidos a clareamento exógeno por meio da densidade óptica radiográfica e verificar se houve ou não mudança estrutural do esmalte dentário por meio da difração de raios X. Para tanto os elementos dentários foram radiografados com o sistema digital direto RVG (Trophy, Vicennes, França) e avaliados quanto à densidade óptica radiográfica pelo programa de edição de imagens Adobe Photoshop 7.0. Os mesmos foram analisados por difração de raios X obtendo-se o resultado em forma de espectro. Os dados da densidade radiográfica foram submetidos à análise estatística Anova e teste T-student. Pelos resultados obtidos verificou-se que os valores de densidade óptica diferiram entre os intervalos inicial, 7 dias e 14 dias da aplicação do agente clareador (p=0,001). Foi possível concluir que a variação nos intervalos de aplicação do agente clareador em esmalte dentário têm influência sobre os valores de densidade óptica das imagens radiográficas iniciais, 7 dias e 14 dias e que este método possibilitou avaliar a progressão da perda mineral em esmalte dentário. A difração de raios X mostrou que não houve mudança estrutural do esmalte dentário, embora tenha havido perda dos componentes inorgânicos caracterizando exposição de uma camada mais cristalina na superfície do esmalte. / Is objective this work evaluate the dental demineralization for fifty teeth premolar humans when submitted the bleaching exogenous for half a from density optical radiographic and verify if he got or not shakeup structural of the enamel dental for half a from diffraction of x-rays. The elements dentals were radiograph , with the system digital RVG (Trophy, Vicennes, França ) and appraised as to the density optical radiographic at image editing package Adobe Photoshop 7.0. The states was analyzed for diffraction of x-rays getting - if the sequel fit of spectrum. The result from density radiographic were submitted the analysis statistics Anova & test T student. For half a from the results obtained verifies - if as the values of density optical differ among the intervals initial , 7 days and end from application of the agent bleaching (p=0,001). Was possible accomplish what the variation on the intervals of application of the agent bleaching in enamel dental they have influence on the subject of the values of density optical of the images radiographic you start , 7 days and ends and that this method allow access the progression from loss mineral in enamel dental. With the diffraction of x-rays showed that there was no shakeup structural of the enamel dental, though it may have been loss from the components inorganic featuring an exposition from a layer more crystal-clear on surface of the enamel.
569

Processamento e caracterização mecânica da liga à base de titânio (Ti-7,5Mo) para confecção de prótese ortopédica /

Corrêa, Maria Emilia Cavalca. January 2014 (has links)
Orientador: Ana Paula Rosifini Alves Claro / Banca: Angelo Caporalli Filho / Banca: Amélia Paqual Marques / Resumo : Nos últimos anos, o aumento da qualidade de vida e o envelhecimento da população, resultou no estudo de novos materiais para aplicações ortopédicas. Biomateriais metálicos, como o titânio e suas ligas, têm sido utilizados devido as suas excelentes propriedades mecânicas e biocompatibilidade. Neste estudo, a viabilidade do uso da liga Ti-7.5Mo na substituição do tecido duro foi avaliada. Os lingotes de liga de Ti-7.5Mo foram fundidos em forno a arco sob atmosfera controlada. Corpos de prova foram usinados a partir de barras obtidas por forjamento rotativo após tratamento térmico. Ensaios de compressão e fadiga foram avaliados para se obter as propriedades mecânicas. Também foi realizada a análise microestrutural (DRX e microscopia óptica). Os resultados obtidos demonstram grande possibilidade da utilização desta liga para aplicações na confecção de implantes de carga como a prótese de quadril / Abstract: In the last years, the increase of the of life expectancy and aging of the population has resulted in the study of new materials for biomedical applications. Metallic biomaterials, such as titanium and its alloys, have been used due their excellent properties such biocompatibility. In this study, the viability of the use Ti-7.5Mo alloy in the replacing of the hard tissue was evaluated. Ingots of the Ti-7.5Mo alloy were obtained in arc melting furnace with inert atmosphere. Bars were obtained after heat treatment and cold work by swaging. Compression,tension test and fatigue tests were use for evaluated the mechanical properties. Also microsctructural analysis was realized by using XRD and optical microscopy. Experiments results indicate that Ti-7.5Mo alloy have Young modulus (65 GPa) lower than other commercial alloys and titanium commercially pure. Alloy exhibited higher ratio strength-to-modulus ratio this property is very interesting for biomedical applications. Processing influenced the performance of the alloy during compression test. Analysis of the results shows the potential of this alloy for biomedical applications due their excellent behavior / Mestre
570

Micropartículas poliméricas biodegradáveis contendo cetorolaco como estratégia tecnológica para liberação controlada intra-ocular /

Rossanezi, Gustavo. January 2012 (has links)
Orientador: Anselmo Gomes de Oliveira / Banca: Leticia Norma Carpentiere Rodrigues / Banca: Osvaldo de Freitas / Banca: Maria Helena Andrade Santana / Banca: Marcos Antonio Corrêa / Resumo: Neste projeto, em continuidade a projetos anteriores, temos como objetivo desenvolver micropartículas biodegradáveis contendo o anti-inflamatório não esteróide cetorolaco (CT) para administração intra-ocular. As micropartículas foram baseadas na estrutura matricial, na qual o fármaco está homogeneamente distribuído na matriz polimérica seca. A técnica de obtenção utilizada no estudo foi a secagem por o Spray drying, a qual pode proporcionar partículas homogêneas e com dimensões apropriadas para a utilização pretendida. Foram obtidas micropartículas com várias proporções fármaco:polímero para evidenciar possíveis interações entre esses componentes. Estudos anteriores permitiram-nos definir que o polímero PLGA 85:15, é o polímero mais apropriado ao tempo de liberação necessário ao uso oftalmológico do cetorolaco. As condições inicias de operação do Spray drier foram estabelecidas em estudos anteriores em nosso grupo. As micropartículas foram caracterizadas por microscopia eletrônica de varredura, pela determinação dos diâmetros médios, por Espectroscopia de Infravermelho (IV), por Análise Térmica (DSC, TG/DTG, DTA) e por Difração de Raios X (DRX). A análise quantitativa do fármaco microencapsulado ou não foi realizada por Espectroscopia UV-Vis. Finalmente, a eficiência terapêutica será verificada in vivo através de estudos de biodisponibilidade em coelhos albinos, conforme protocolos estabelecidos juntamente com as equipes de oftalmologia do Hospital de Olhos de Araraquara e do Departamento de oftalmologia da Universidade Federal de São Paulo-Unifesp. A metodologia proposta mostrou-se eficiente na preparação de micropartículas de PLGA contendo CT nas concentrações de 15%, 25%, 35% e 50%, entretanto a partir da concentração de 35% as partículas não assumem forma definida... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In this project, continuing the previous projects, we aim to develop biodegradable microparticles containing the NSAID ketorolac (CT) for intraocular administration. The microparticles were based on the matrix structure, in which the drug is homogeneously distributed in the dried polymer matrix. The technique of obtaining used in this study was dried by the spray drying, which can provide the particles with homogeneous dimensions appropriate for the intended use. Microparticles were obtained with various ratios drug: polymer for evidence of possible interactions between these components. Previous studies have enabled us to establish that the PLGA 85:15 polymer, the polymer is more appropriate to the release time necessary for the ophthalmic use of ketorolac. The initial conditions of operation of the spray drier were established in previous studies in our group. The microparticles were characterized by scanning electron microscopy, by determining the average diameter by infrared spectroscopy (IR) for Thermal Analysis (DSC, TG / DTG, DTA) and X-Ray Diffraction (XRD). Quantitative analysis or microencapsulated drug has not been performed by UV-Vis spectroscopy. Finally, the therapeutic effectiveness is verified through in vivo bioavailability studies in rabbits, according to established protocols with the teams of Ophthalmology, Hospital de Olhos de Araraquara and Department of Ophthalmology, Federal University of São Paulo- UNIFESP. The proposed method was effective in the preparation of PLGA microparticles containing CT in concentrations of 15%, 25%, 35% and 50%, but at concentrations of 35% particles do not assume a defined shape, while at lower concentrations than the predominant form is spherical with a tendency to agglomerate. The average particle diameter increases as... (Complete abstract click electronic access below) / Doutor

Page generated in 0.0516 seconds