Spelling suggestions: "subject:"respiratory actionfunction"" "subject:"respiratory functionaction""
71 |
Avaliação da espirometria de gestantes expostas à poluição atmosférica da Região Metropolitana de São Paulo / Spirometric evaluation of pregnant women exposed to air pollution in the metropolitan region of São PauloPastro, Luciana Duzolina Manfré 11 March 2015 (has links)
Introdução: A poluição do ar pode levar a alterações no sistema respiratório, especialmente entre certos grupos, como as gestantes, que são mais vulneráveis aos efeitos de poluentes atmosféricos. A gravidez é um período que envolve alterações funcionais e anatômicas no corpo da mulher, incluindo alterações na função pulmonar, o que pode ser avaliado por espirometria, um método simples, barato e eficaz. Objetivos: Os objetivos deste estudo foram a usar a espirometria para avaliar a função pulmonar de mulheres no primeiro trimestre (T1) e no terceiro trimestre (T3) de gravidez e analisar a influência da exposição a poluição do ar sobre os parâmetros espirométricos. Metodologia: O estudo foi realizado no Ambulatório de Obstetrícia do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP) entre Maio de 2011 e Agosto de 2013. Foram aplicados os seguintes critérios de inclusão: gestação única, idade gestacional no dia da primeira espirometria inferior a 13,86 semanas, ausência de doenças maternas préexistentes, preparação adequada para o teste de espirometria e amostradores passivos individuais (APIs) adequados para análise. Os critérios de exclusão foram a mudança de endereço, o aborto, o teste de espirometria inadequado e desistência de participar do projeto. Os APIs contendo dois filtros de celulose embebidos com solução absorvente para capturar os níveis de NO2 e outros dois filtros embebidos com solução de índigo blue para medir os níveis de O3 foram entregues às gestantes cerca de 12 dias antes da realização do teste de espirometria. Dados do relatório anual da Companhia Ambiental do Estado de São Paulo (CETESB) para o mesmo período dos amostradores passivos, foram utilizados. Para a espirometria, um espirômetro Koko foi utilizado, sendo considerada as duas melhores curvas para avaliar os resultados da função pulmonar. Análise estatística: Foi utilizado o teste Mann-Whitney para grupos independentes e Wilcoxon para os dependentes. Devido à pequena variação na exposição à poluição, a exposição no primeiro trimestre (Q1) e quarto trimestre (Q4) foram comparados para cada poluente em T1 e T3 através da análise nãoparamétrica para medidas repetidas. Resultados: Houve uma redução estatisticamente significativa dos valores absolutos (T1: 3,690 L; T3: 3,475 L) e preditos (T1: 101%, T3: 97,5%) da capacidade vital forçada (CVF), p < 0,0001. E uma redução estatisticamente significativa dos valores absolutos (T1: 3.080 L; T3: 2.950 L) e preditos (T1: 99%, T3: 96%) do volume expiratório forçado no primeiro segundo do procedimento (FEV1), p < 0,0001. A exposição à poluição foi semelhante em ambos os trimestres, exceto para a exposição de NO2 no API, o que foi inferior em T3 (p = 0,001). Independentemente do trimestre (T1 ou T3), o grupo de mulheres do Q4 (T1: 97,5%; T3: 98,5%) teve NO2 estatisticamente maior dos valores do fluxo expiratório forçado de 25 a 75% do procedimento (FEF25-75%) do que o grupo em Q1 (T1: 80%; T3: 92%). O grupo de mulheres do Q1 do NO2 teve um aumento significativo neste parâmetro de T1 a T3 (p = 0,042). Em termos de valores absolutos da relação FEV1/FVC, o grupo de mulheres no Q1 mostrou um aumento estatisticamente significativo neste parâmetro de T1 (0,810 L) para T3 (0,840 L) (p = 0,026). Em T3, os valores absolutos e relativos da CVF foram estatisticamente maiores para o grupo de gestantes do Q4 (3,535 L; 100,5%) de NO2 do que para o grupo de gestantes do Q1 (3,345 L; 92%). O grupo de gestantes do Q4 de O3 mostrou o VEF1 estatisticamente maior eno T1 (102,5%) do que no T3 (95,5%) (p < 0,001). Independentemente do trimestre, o grupo de gestantes do Q4 do MP10, teve valores absolutos da CVF (T1: 3.520 L; T3: 3,265 L) e os valores de VEF1 (T1: 2,915 L; T32.840 L) foram estatisticamente menor do que para o grupo em Q1 (FVC - T1: 3.780 L; T3: 3.580 L) (FEV1 - T1: 3.180 L; T3: 3.065 L) p = 0,040; p = 0,035, respectivamente. Valores absolutos e preditos do pico de fluxo expiratório (PEF) em T1 das mulheres do Q4 (5,995 L; 80%) do MP10 foram estatisticamente menores do que para as mulheres no Q1 (6,675 L; 85%) (p = 0,006; p = 0,041 , respectivamente). Mulheres grávidas em Q4 (0,835 L) do MP10 tiveram os valores da relação VEF1/CVF estatisticamente menores valores do que as mulheres do Q1 (0,850 L) (p = 0,029). Conclusão: Exposição a NO2 e O3 foi associada com o aumento de alguns dos parâmetros de espirometria, indicando a presença de uma possível função de defesa pulmonar ou mecanismo compensatório em mulheres grávidas, quando expostos a esses poluentes. O MP10 foi associado com a redução de alguns parâmetros de espirometria durante a gravidez, indicando os efeitos danosos do poluente para a função do pulmão de mulheres grávidas / Introduction - Air pollution can lead to alterations to the respiratory system, particularly among certain groups, such as pregnant women, which are more vulnerable to the effects of air pollutants. Pregnancy is a period involving functional and anatomical changes in a woman\'s body. These changes include pulmonary function, which can be assessed by spirometry, a simple, inexpensive and effective method. Objectives - The aims of this study were to use spirometry to evaluate pulmonary function in pregnant women in the first trimester (T1) and the third trimester (T3) of pregnancy and to analyze the influence of air pollution exposure on the spirometry parameters. Methodology - This study was carried out at the Obstetrics Clinic of Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP) between May 2011 and August 2013. The following inclusion criteria were applied: singleton pregnancy, 13.86 weeks gestational age at the first spirometry, no preexisting maternal diseases, adequate preparation for the spirometry test and individual passive samplers (IPAs) suitable for analysis. The exclusion criteria were change of address, abortion, inadequate spirometry testing and withdrawal from the project. The exposure to pollutants prior to the spirometry tests was assessed in T1 and T3. The passive samplers containing two cellulose filters soaked with absorbent solution to capture NO2 levels and two other filters soaked with indigo solution to measure O3 levels were provided to the pregnant women roughly 12 days prior to the spirometry test. Data from the environmental Company of São Paulo State (CETESB) annual report for the same period the passive samplers were used. For the spirometry, a Koko spirometer was used, taking the two best curves to assess lung function results. Statistical Analysis - We used Mann- Whitney tests for independent groups and Wilcoxon for the dependent ones. Due to the small variation in the exposure to pollution, exposure in the first quarter (Q1) and fourth quarter (Q4) were compared for each pollutant in T1 and T3 through non-parametrical analysis for repeated measurements. Results - It has been noted a significant statistical reduction of absolute and predicted forced vital capacity (FVC) values (3.690 L; 3.475 L) and forced expiratory volume during the first second of the procedure (FEV1) (3.080 L; 2.950 L) from T1 to T3. Exposure to pollution was similar in both trimesters, except for exposure to NO2 in the passive sampler, which was lower in T3 (p = 0.001). Regardless of the trimester (T1 or T3), the group of pregnant women in Q4 (97.5%; 98.5%) of NO2 had statistically higher predicted forced expiratory values of 25 to 75% of the procedure (FEF25-75%) than the group in Q1 (80%; 92%). Pregnant women in Q1 of NO2 had a significant increase in this parameter from T1 to T3 (p = 0.042). In terms of absolute FEV1/FVC values, pregnant women in Q1 showed a statistically significant rise in this parameter from T1 (0.810 L) to T3 (0,840 L) (p = 0,026). In T3, absolute and predicted FVC values were statistically higher for the group of pregnant women in Q4 (3.535 L; 100.5%) of NO2 than for the group of pregnant women in Q1 (3.345 L; 92%). Pregnant women in Q4 of O3 displayed statistically higher FEV1 values in T1 (102.5%) than in T3 (95.5%) (p < 0.001). Regardless of trimester, for the group of pregnant women in Q4 of MP10, absolute FVC (T1:3 .520 L; T3: 3.265 L) and FEV1 values (T1: 2.915 L; T3: 2.840 L) were statistically lower than for the group in Q1 (FVC - T1: 3.780 L; T3: 3.580 L) (FEV1 - T1: 3.180 L; T3: 3.065 L) p = 0.040; p = 0.035 respectively. Absolute and predicted peak expiratory flow (PEF) in T1 of pregnant women in Q4 (5.995 L; 80%) of MP10 were statistically lower than for the pregnant women in Q1 (6.675 L; 85%) (p = 0.006; p = 0.041, respectively). Pregnant women in Q4 (0.835 L) of MP10 displayed statistically lower absolute FEV1/FVC values than the pregnant women in Q1 (0.850 L) (p = 0.029). Conclusion - Exposure to NO2 and O3 was associated with the increase in some of the spirometry parameters, indicating the presence of a possible lung function defense or compensatory mechanism in pregnant women when exposed to those pollutants. The MP10 was associated with the reduction of some spirometry parameters during pregnancy, indicating the harmful effects of that pollutant to the lung function of pregnant women
|
72 |
Efeito da medida pré-operatória de força da musculatura respiratória no resultado do transplante de fígado / Effect of preoperative respiratory muscle strength on liver transplant outcome.Machado, Carla da Silva 30 May 2007 (has links)
INTRODUÇÃO: Em pacientes com doença hepática avançada, pode ocorrer diminuição das pressões inspiratória máxima (PImáx) e expiratória máxima (PEmáx), respectivamente. Nos pacientes submetidos a transplante de fígado (Tx) essas alterações são agravadas no pós-operatório imediato. Para nosso conhecimento, a importância da medida pré-operatória da força da musculatura respiratória na evolução pós-operatória ainda não foi investigada no Tx. OBJETIVO: Avaliar o efeito das medidas pré-operatórias de força da musculatura respiratória no resultado do Tx. MÉTODO: Foram estudados retrospectivamente 228 pacientes de ambos os sexos, sem limite de idade, submetidos a primeiro Tx eletivo, com enxerto proveniente de doador cadáver. As medidas de PImáx e PEmáx foram obtidas imediatamente antes do transplante a partir do volume residual (VR) e da capacidade pulmonar total (CPT), respectivamente. Os pacientes foram classificados conforme a ocorrência de valores absolutos de pressão respiratória menores ou iguais a 50 cm H2O. As variáveis estudadas foram o tempo de ventilação mecânica pós-operatório, a necessidade de re-intubação orotraqueal ou de ventilação mecânica não-invasiva, o tempo de internação e a sobrevida dos pacientes. RESULTADO: Os resultados mostraram que os valores observados de PImáx e PEmáx estavam abaixo de 50 cm H2O em 19,7% (45/228) e 14,5% (33/228) dos pacientes, respectivamente. A freqüência de óbito até 6 meses após o transplante foi de 26/183 (14,2%) nos pacientes com PImáx > 50 cm H2O e de 15/45 (33,3%) nos pacientes com PImáx mais baixa (p=0,003). A sobrevida de 1, 3 e 5 anos foi 84%, 77% e 71% no grupo com PImáx > 50 cm H2O e 57%, 50% e 50% no grupo com PImáx mais baixa (p=0,0024). Em relação à PEmáx, essas probabilidades foram 80%, 74% e 69% no grupo com valores maiores que 50 cm H2O e 66%, 59% e 51% nos pacientes com força expiratória menor (p=0,1039). Não houve diferença estatisticamente significante em relação às demais variáveis analisadas. CONCLUSÃO: Pacientes com PImáx baixa apresentam maior mortalidade após o transplante de fígado. Entretanto, não foram encontrados efeitos estatisticamente significantes da medida pré-operatória da força da musculatura respiratória nas variáveis de resposta mais diretamente relacionadas com alterações respiratórias. / INTRODUCTION: Maximal inspiratory pressure (PImax) and maximal expiratory pressure (PEmax) were reduced in most patients with end-stage liver disease. In recipients of orthotopic liver transplantation (OLT), respiratory muscle weakness is worsened in the immediate postoperative period. In patients undergoing coronary artery bypass grafting, respiratory muscle weakness is associated with prolonged postsurgical mechanical ventilation and higher incidence of pulmonary complications. However, to our knowledge, no study has evaluated the effect of preoperative respiratory muscle strength on the postoperative course of OLT. AIM: To evaluate the effect of preoperative respiratory muscle strength on OLT outcome. METHODS: We reviewed 228 deceased donors elective OLT performed between 28th December, 1994 and 30th July, 2001. PImax e PEmax were assessed at residual volume and total lung capacity, respectively, immediately before OLT. Patients were classified according to the occurrence of muscle strength absolute values equal or lower than 50 cm H2O. The following response variables were analyzed: duration of postoperative mechanical ventilation, incidence of tracheal reintubation and noninvasive positive pressure ventilation, length of hospital stay and patient survival. RESULTS: PImax e PEmax were equal or lower than 50 cm H2O in 19.7% (45/228) and 14.5% (33/228) of patients, respectively. Patient mortality up to 6 months after OLT was 14.2% (26/183) in the group with PImax > 50 cm H2O and 33.3% (15/45) in the group with lower values (p=0.003). The 1-, 3-, and 5-year patient survival was 84%, 77% and 71% for the group with PImax > 50 cm H2O and 57%, 50% and 50% for the group with lower values (p=0.0024). In relation to PEmax, these probabilities were 80%, 74% e 69% for the group with higher values and 66%, 59% e 51% for patients with respiratory muscle weakness (p=0.1039). There is no significant difference regarding the others variables analyzed. CONCLUSION: Patients with low PImax present higher mortality after OLT. However, there are no statistically significant effects of the preoperative respiratory muscle strength on the response variables more directly related to the pulmonary outcome.
|
73 |
Associação entre biomarcadores renais, funcionalidade, endurance e parâmetros nutricionais em pacientes com insuficiência renal crônica não dialíticos com e sem intervenção fisioterapêutica em um ambulatório de nefrologia / Association between renal biomarkers, functionality, endurance and nutritional parameters in patients chronic kidney disease not on dialysis with and without physical therapy intervention in an outpatient nefrologyFracini, América Cristina 30 June 2015 (has links)
INTRODUÇÃO Pacientes com doença renal crônica sofrem alterações musculoesqueléticas nos estágios iniciais da doença associadas a fatores como alteração de substratos séricos, capacidade funcional, qualidade de vida e parâmetros nutricionais. O objetivo deste estudo foi avaliar o desempenho funcional, qualidade de vida, e parâmetros respiratórios em pacientes com doença renal crônica não dialítica segundo o estágio da doença renal. MÉTODOS Foram selecionados 26 indivíduos acompanhados pelo Serviço de Nefrologia do Instituto Central da Faculdade de Medicina da Universidade de São Paulo, com diagnóstico de doença renal crônica não dialíticos, e taxa de filtração glomerular abaixo de 45 mL/min, foram excluídos pacientes com doenças reumatológicas, respiratórias, neurológicas ou que apresentassem limitações para a execução dos testes funcionais. Foram aplicados os seguintes instrumentos: questionário de Qualidade de Vida (SF-36), o questionário Internacional de Nível de Atividade Física (IPAQ), foi realizado os seguintes testes: teste de Caminhada de Seis Minutos, teste de Sentar e Levantar, e o teste de Preensão Palmar, foram aferidas também as pressões máximas inspiratórias e expiratórias e volumes pulmonares através da manuvacuometria e exames laboratoriais de rotina. RESULTADOS Os dados do grupo geral foram comparados com os encontrados na literatura demonstrando menor capacidade funcional e respiratória do que indivíduos saudáveis de mesmo gênero e faixa etária. Os indivíduos avaliados também foram subdivididos em dois grupos através da estimativa da taxa de filtração glomerular pela formula CKD-EPI, o primeiro grupo com taxa de filtração glomerular menor que 30 mL/min e o segundo grupo com taxa de filtração glomerular maior ou igual a 30 mL/min. Foram encontradas diferenças significantes quanto a: pressão expiratória máxima (P=0.04) onde os pacientes com pior função renal apresentaram maior força muscular expiratória, paratormônio (P= 0.02), fosforo (P= 0.04) e ureia (P= 0.00) . CONCLUSÃO: Concluiu se que indivíduos com doença renal crônica apresentam diferenças em relação aos parâmetros respiratórios, exames séricos diferentes estágios da doença renal crônica antes da terapia renal substitutiva / INTRODUCTION Patients with chronic kidney disease (CKD) suffer musculoskeletal disorders in the early stages of the disease associated with factors such as change in serum substrates, functional capacity, quality of life and nutritional characteristics. The aim of this study was to evaluate the functional performance, quality of life, and respiratory parameters in patients with CKD not requiring dialysis according to the stage of kidney disease. METHODS We selected 26 individuals accompanied by the Nephrology Department of the Central Institute of the Faculty of Medicine, University of São Paulo, diagnosed with chronic kidney disease not on dialysis, and glomerular filtration rate below 45 mL / min, patients were excluded with rheumatic diseases, respiratory, neurological or who present limitations for the execution of functional tests. The following instruments were applied: Quality of Life questionnaire (SF-36), the International Physical Activity Questionnaire (IPAQ), was performed the following tests: the Six Minutes Walk test, Sitting and Rising test, and Hand Grip Strength test were also measured the maximum inspiratory and expiratory pressure and lung volumes through manuvacuometria and routine laboratory tests. RESULTS The results presented by the general group were compared with those found in the literature showing lower functional and respiratory capacity than healthy individuals of the same gender and age. The evaluated individuals were also subdivided into two groups by means of the glomerular filtration rate by the formula CKD-EPI, the first group of glomerular filtration rate lower than 30 ml / min and the second group with higher glomerular filtration rate or equal to 30 ml / min. Significant differences were found regarding: maximal expiratory pressure (P 0.04) where patients with poor kidney function had higher expiratory muscle strength, parathyroid hormone (P = 0.02) and phosphorus (P 0.04). CONCLUSION: We conclude that individuals with chronic kidney disease have differences from respiratory parameters, different blood tests stages of chronic kidney disease before renal replacement therapy
|
74 |
Mobilidade diafragmática em pacientes com DPOC: avaliação ultra-sonográfica do deslocamento crânio-caudal do ramo esquerdo da veia porta / Diaphragm mobility in COPD patients: ultrasound assessment of the craniocaudal displacement of the left branch of the portal veinYamaguti, Wellington Pereira dos Santos 22 June 2007 (has links)
O objetivo desse estudo foi avaliar a relação da mobilidade diafragmática com a função pulmonar e a força muscular respiratória em indivíduos com DPOC, utilizando a mensuração ultra-sonográfica do deslocamento crânio-caudal do ramo esquerdo da veia porta. Foram estudados 54 pacientes portadores de DPOC com hiperinsuflação pulmonar e 20 sujeitos saudáveis. Os parâmetros avaliados foram: mobilidade diafragmática, função pulmonar e as pressões respiratórias máximas. Pacientes com DPOC apresentaram menor mobilidade do diafragma (36,46 ± 10,90 mm) quando comparados a indivíduos saudáveis (46,33 ± 9,47) (p = 0,001). Nos indivíduos portadores de DPOC foram verificadas uma forte correlação com os parâmetros da função pulmonar que quantificam o aprisionamento de ar (VR: r = -0,60; p < 0,001; VR/CPT: r = -0,72; p < 0,001), uma moderada correlação com a obstrução de vias aéreas (VEF1: r = 0,55, p < 0,001; resistência das vias aéreas: r = -0,32, p = 0,02) e uma fraca correlação com a hiperinsuflação pulmonar (CPT: r = -0,28, p = 0,04). Não foi observada relação entre a mobilidade do diafragma e a força muscular respiratória (PImax: r = -0,11 e p = 0,43; PEmax: r = 0,03 e p = 0,80). Nossos resultados sugerem que a redução da mobilidade do diafragma em pacientes com DPOC ocorre principalmente devido ao aprisionamento de ar, não sendo influenciada pela hiperinsuflação pulmonar ou pela força muscular respiratória. / The purpose of this study was to use ultrasound to measure the craniocaudal displacement of the left branch of the portal vein in order to evaluate the relationship between pulmonary function and diaphragm mobility, as well as that between respiratory muscle strength and diaphragm mobility, in COPD patients. We studied 54 COPD patients with pulmonary hyperinflation, together with 20 healthy subjects. Pulmonary function, maximal respiratory pressures, and diaphragm mobility were evaluated. COPD patients presented less diaphragm mobility than did healthy individuals (36.46 +/- 10.90 mm vs. 46.33 +/- 9.47 mm, respectively) (p = 0.001). In COPD patients, we found that diaphragm mobility correlated strongly with pulmonary function parameters that quantify air trapping (RV: r = -0.60; p < 0.001; RV/TLC: r = -0.76; p < 0.001), moderately with airway obstruction (FEV1: r = 0.55, p < 0.001; airway resistance: r = -0.32, p = 0.02), and weakly with pulmonary hyperinflation (TLC: r = -0.28, p = 0.04). No relationship was observed between diaphragm mobility and respiratory muscle strength (maximal inspiratory pressure: r = -0.11 and p = 0.43; maximal expiratory pressure: r = 0.03 and p = 0.80). The results of this study suggest that the reduction in diaphragm mobility in COPD patients occurs mainly due to air trapping and is not influenced by respiratory muscle strength or pulmonary hyperinflation.
|
75 |
"Estudo comparativo de exercícios respiratórios em piscina aquecida para asmáticos graves e moderados: impacto de uma sessão" / A comparative study of breathing exercises in warm-water pool for moderate and severe asthma patients : a single session effectsPereira, Katia de Souza 29 September 2005 (has links)
Foi elaborado um programa de intervenção para pacientes asmáticos através da aplicação inédita de exercícios respiratórios em piscina coberta e aquecida, conduzidos por um fisioterapeuta, comparando-se o impacto de uma intervenção única do mesmo aplicado em solo. Participaram do estudo 40 pacientes adultos, asmáticos persistentes de moderados a graves, sem acompanhamento medicamentoso, fazendo uso apenas de ß2 agonista de curta duração. Avaliou-se a função pulmonar, a força muscular, a cirtometria, postura e escore de ansiedade. Verificou-se que a intervenção em água não foi prejudicial para os sujeitos, oferecendo alguns benefícios que superam aqueles encontrados em solo, como a mobilidade da caixa torácica, reeducação do padrão respiratório, melhora do desconforto respiratório e do estado de ansiedade / It was developed an original exercises program for asthmatic patients using breathing exercises in warm-water pool, conducted by a physiotherapist and subsequently compared with the same program performed in land in order to evaluate the effects of a single session respiratory exercise program. 40 adult patients, with moderated to severe asthma, without medical treatment, using only short action ß2 agonist were randomly allocated this study. It was evaluated the lung function, muscle strength, thoracic and abdominal circumference measurement, posture and anxiety. It was concluded that the water intervention is not harmful for the patients, offering some benefits which exceed those obtained in land, as thoracic mobility, reeducation of the respiratory pattern, improvement of the dyspnea and anxiety scores
|
76 |
Uticaj šestomesečne inhalatorne kortikosteroidne terapije na vrednosti interleukina-33 u serumu kod dece sa alergijskom astmom / The effect of six-month inhaled corticosteroid treatment on IL-33 serum levels in children with allergic asthmaMilanović Borko 10 April 2019 (has links)
<p>Uvod: Interleukin 33 (IL-33) ima značajnu ulogu u inflamatornim i autoimunskim oboljenjima, ali se sve više proučava njegov značaj u imunopatogenezi različitih alergijskih oboljenja, uključujući i alergijsku astmu (AA). Cilj: Ispitivanje vrednosti IL-33 u serumu pacijenata sa AA pre i posle šestomesečne inhalatorne kortikosteroidne terapije (ICS Th) i povezanosti dobijenih vrednosti IL-33 sa određenim kliničkim i laboratorijskim karakteristikama ovih pacijenata. Metode: Vrednost IL-33 u serumu određena je kod 61 pacijenta sa AA pre započinjanja i posle sprovedne šestomesečne ICS Th i kod 30 zdrave dece. U obradi podataka primenjene su standardne metode deskriptivne i analitičke statistike. Rezultati: Kod pacijenata sa nelečenom AA, serumske vrednosti IL-33 su signifikantno veće u odnosu na pacijente kod kojih je sprovedena šestomesečna ICS Th (p<0,05), kao i u odnosu na zdravu decu (p<0,01). Pacijenti sa AA koji su tokom 6 meseci lečeni sa ICS Th i zdrava deca imaju slične vrednosti IL-33 u serumu (p>0,05). Kod pacijenata sa AA pre započinjanja i 6 meseci posle primene ICS Th ne postoji signifikantna korelacija između vrednosti IL-33 u serumu i eozinofilnih granulocita periferne krvi (p>0,05), eozinofilnih granulocita u nazalnom sekretu (p>0,05) i ukupnog IgE u serumu (p>0,05). Kod pacijenata sa nelečenom AA postoji signifikantna negativna korelacija između vrednosti serumskog nivoa IL-33 i sledećih parametara plućne fukcije: FEV1 (p<0,05), FEV1/FVC (p<0,05), PEF(p<0,05) i MEF 25/75 (p<0,05). Posle šestomesečne ICS Th poboljšava se plućna funkcija, odnosno dolazi do porasta brzine protoka vazduha u disajnim putevima kao i promena u plućnim volumenima u zavisnosti od stepena opstrukcije u odnosu na vrednosti pre uključenja antiinflamatorne terapije (FEV1, FVC, FEV1/FVC, PEF, MEF 25/75, za sve vrednosti p<0,01). Dok je signifikantna negativna korelacija dokazana između IL-33 i vrednosti FEV1 (p<0,01), FVC (p<0,01) i PEF (p<0,05). Zaključak: Serumski nivo IL-33 je značajno povišen kod dece sa nelečenom, odnosno nekontrolisanom AA. Šestomesečna primena ICS dovodi do značajne redukcije IL-33 u serumu čije su vrednosti u negativnoj korelaciji sa vrednostima FEV1, FVC i PEF, odnosno pozitivnoj korelaciji sa težinom i kontrolom AA. Rezultati naše studije ističu da IL-33 ima značajnu ulogu u imunopatogenezi AA. Određivanje serumske vrednosti IL-33 može biti koristan indikator težine AA.</p> / <p>Introduction: Interleukin 33 (IL-33) plays a significant role in inflammatory and autoimmune diseases, but its significance in the immunopathogenesis of various allergic diseases including allergic asthma (AA) has gained increasing attention in research over recent years. Objective: Testing serum levels of IL-33 in patients with AA before and after a six-month inhaled corticosteroid therapy (ICS Th) and correlation of IL-33 values with specific clinical and laboratory characteristics of these patients. Methods: Serum levels of IL-33 were determined in 61 patients with AA prior to the initiation of ICS Th and following the six-month ICS Th as well as in 30 healthy children. Data processing was performed applying standard methods of descriptive and analytical statistics. Results: In patients with untreated AA, serum levels of IL-33 were significantly higher as compared to the patients who have received a six month ICS Th (p <0.05) as well as to healthy children (p <0.01). Patients with AA, who were treated with ICS Th for six months, and healthy children have similar serum IL-33 (p> 0.05). In patients with AA, significant correlation between serum IL-33 levels and eosinophilic peripheral blood granulocytes (p>0.05), eosinophilic granulocytes in nasal secretion (p>0.05) and the total IgE in serum has not been observed for the period prior to initiation and 6 months after the administration of ICS Th. In patients with untreated AA, there is significant negative correlation between serum IL-33 and the following pulmonary functions test results: FEV1 (p<0.05), FEV1/FVC (p<0.05), PEF (p<0.05) and MEF 25/75 (p<0.05). After a six-month ICS Th, significant improvement of pulmonary functions was evident, that is, increase in airflow speed and lung volume change as compared to the values determined before the initiation of the anti-inflammatory therapy (FEV1, FVC, FEV1/FVC, PEF, MEF 25/75, for all values p<0.01). Significant negative correlation between IL-33 and the values of FEV1 (p<0.01), FVC (p<0.01)and PEF (p<0.05) has been established. Conclusion: Serum level of IL-33 is significantly elevated in children with untreated, i.e., uncontrolled AA. A six-month ICS Th asthma treatment results in significant reduction of serum levels of IL-33. This level is negatively correlated with FEV1, FVC and PEF values while positively correlated with the severity of the disease and control of AA. The results of our study point out that IL-33 plays an important role in the immunopathogenesis of AA. Quantification of serum IL-33 levels can be a useful indicator of the severity of AA.</p>
|
77 |
Avaliação pulmonar funcional, tomográfica e de escores de gravidade de crianças e adolescentes com dermatomiosite juvenil (DMJ) / Assessment of pulmonary function, tomographic findings, and severity scores in children and adolescents with childhood-onset juvenile dermatomyositis (JDM)Coutinho, Douglas Silva 17 July 2015 (has links)
Introdução: Alterações pulmonares estruturais e funcionais podem ocorrer na dermatomiosite juvenil (DMJ). O objetivo foi avaliar a função pulmonar de pacientes com DMJ e analisar correlações entre os valores encontrados e os escores: tomográfico, de atividade e dano cumulativo da doença e qualidade de vida. Métodos: Estudo prospectivo, transversal, com 20 pacientes com DMJ entre 6 e 18 anos. Realizados testes de espirometria, pletismografia, difusão de monóxido de carbono (DLCO), teste de caminhada de 6 minutos (TCam6min) e tomografia de tórax (TC). Avaliados também: escores de atividade da doença (DAS), força muscular (CMAS e MMT), dano cumulativo (MDI) e qualidade de vida (PedsQL). Resultados: Vinte pacientes foram incluídos (média de 11,6 anos). Houve obstrução leve ou moderada em 35% dos pacientes, redução da difusão em 20%. Anormalidades espirométricas e/ou da difusão em 45% dos pacientes. Na pletismografia: CPT reduzida em 25% dos pacientes, condutância em 50% e relação VR/CPT em 35%. Treze pacientes realizaram TC sendo 8 alteradas com padrão intersticial(n=6) e misto(n=2). As correlações significativas (p < 0,05) foram: VEF1/CV versus DAS, PedsQL, CMAS e TC; condutância versus DAS, MDI e PedsQl; TCam6Min versus CMAS; DLCO versus MDI e CMAS; TC versus MDI, FEF 25%-75%, condutância, CMAS, PedsQL e DAS. Conclusão: A pletismografia, DLCO e o TCam6min são testes complementares na detecção de distúrbios funcionais em pacientes com DMJ. A existência de correlações significativas entre os parâmetros funcionais, estruturais e de dano cumulativo demonstram que as anormalidades da função pulmonar podem ter relação com o controle, gravidade e atividade da doença e influenciar na qualidade de vida desses pacientes. O distúrbio funcional obstrutivo, por doença inflamatória das vias aéreas, pode ser uma alteração precoce da doença pulmonar na DMJ / Background: Structural and functional pulmonary changes may occur in juvenile dermatomyositis (JDM). The objective of this study was to assess the pulmonary function of patients with JDM and the correlations between pulmonary function and scores for chest tomography, disease activity, cumulative damage, and quality of life. Methods: This prospective, cross-sectional study evaluated 20 patients with JDM aged between 6 and 18 years. Spirometry, plethysmography, diffusing capacity of the lungs for carbon monoxide (DLCO), 6-minute walk test (6MWT), and chest tomography (CT) examinations were performed. Disease Activity (DAS), muscle strength (CMAS and MMT), cumulative damage (MDI), and quality of life (PedsQL) scores were also evaluated. Results: Twenty patients were included in the study (mean age of 11.6 years). Mild or moderate pulmonary obstruction was observed in 35% of patients, and decreased pulmonary diffusion was observed in 20% of patients. Spirometric and/or diffusion abnormalities occurred in 45% of patients. With regard to the plethysmography results: total lung capacity (TLC) decreased in 25% of patients, conductance decreased in 50% of patients, and the residual volume (RV)/TLC ratio decreased in 35% of patients. Thirteen patients underwent CT; of these, 8 cases involved interstitial changes (n=6) and mixed disorders (n=2). The significant correlations (p < 0.05) were: forced expiratory volume in one second (FEV1)/vital capacity (VC) versus DAS, PedsQL, CMAS, and CT; conductance versus DAS, MDI, and PedsQL; 6MWT versus CMAS; DLCO versus MDI and CMAS; CT versus MDI, forced expiratory flow between 25% and 75% of vital capacity (FEF25-75%), conductance, CMAS, PedsQL, and DAS. Conclusion: Plethysmography, DLCO, and 6MWT can be used as complementary tests for the detection of functional disorders in patients with JDM. The significant correlations between functional, structural, and cumulative damage parameters indicate that pulmonary function abnormalities may be associated with disease control, severity, and activity and can influence the quality of life of these patients. Obstructive functional disorder due to inflammatory disease of the airways may constitute an early change in lung disease in JDM
|
78 |
Validação de metodologia de avaliação da função pulmonar em pacientes submetidos à laringectomia total / Validation of the methodology for the assessment of the pulmonary function in patients submitted to total laryngectomyCastro, Mario Augusto Ferrari de 05 October 2015 (has links)
Introdução: Pacientes com câncer de laringe costumam apresentar histórico de tabagismo. Nos pacientes submetidos à tratamento cirúrgico, as complicações pulmonares podem levar à morte no período pós-operatório. Um método com dispositivo extratraqueal padronizado, simples e de baixo custo para a avaliação pulmonar dos pacientes laringectomizados seria muito útil. Objetivo: Validar a metodologia para a avaliação pulmonar em pacientes submetidos à laringectomia total por meio da aplicação de um dispositivo extratraqueal adesivo. Métodos: Participaram deste estudo transversal 50 pacientes submetidos à laringectomia total há pelo menos seis meses como modalidade de tratamento para o câncer de laringe em acompanhamento no Serviço de Cirurgia de Cabeça e Pescoço do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo. Por meio da anamnese e do prontuário dos pacientes foram obtidos dados demográficos, tabagismo, a presença de doenças respiratórias nos últimos 30 dias, dados acerca do tumor e sobre o tratamento realizado. Os testes de função pulmonar foram utilizados para caracterizar a presença de limitação funcional respiratória e o padrão funcional do paciente laringectomizado. Na intenção de avaliar a reprodutibilidade dos exames realizados, foram utilizados parâmetros com respectivos critérios de aceitação dos exames. Os critérios de reprodutibilidade são indicadores de exatidão. Foi feita a comparação desses parâmetros com 50 exames realizados em pacientes não laringectomizados, no mesmo período com o mesmo equipamento, pareados para idade e gênero. Resultados: Em todos os casos de nosso estudo, uma vedação aérea foi mantida durante todo o procedimento com o uso do dispositivo extratraqueal adesivo. Após a realização dos testes de função pulmonar, encontramos que 44% dos pacientes apresentavam um padrão respiratório normal e 56% alterado. Comparando a frequência e porcentagem dos exames rejeitados entre os laringectomizados e o grupo controle, dos nove parâmetros avaliados, cinco foram exatamente iguais, três apresentaram frequência de rejeição maior no grupo controle e somente um mostrou uma maior frequência de exames rejeitados no grupo dos pacientes submetidos à laringectomia total. O total de exames rejeitados foi maior no grupo controle (72%) do que no grupo dos laringectomizados (46%). Conclusões: A maioria dos pacientes submetidos à laringectomia total apresenta função pulmonar alterada, de caráter obstrutivo, na maioria das vezes, devido ao histórico de tabagismo. A metodologia para a avaliação da função pulmonar por meio do uso do dispositivo extra-traqueal proposto é confiável, precisa e reprodutível / Introduction: Laryngeal cancer patients usually have a smoking history. In patients submitted to laryngectomy, pulmonary complications may lead to death in the post-operative phase. A simple and low-cost method with a standardized extra-tracheal device for the pulmonary assessment of laryngectomized patients would be very useful. Objective: Validate the methodology for pulmonary assessment in patients submitted to total laryngectomy through the application of an adhesive extra-tracheal device. Methods: This transversal study included 50 patients who had been submitted to total laryngectomy at least six months prior to this investigation, as choice of treatment for laryngeal cancer while followed by the Head and Neck Service from Hospital das Clínicas, São Paulo University. Through anamnesis and patients medical records the following information was collected: demographic data, smoking habits, the presence of respiratory diseases in the last 30 days, as well as information about the tumor and the performed treatment. Pulmonary tests were used to characterize the presence of respiratory functional limitation as well as laryngectomized patient\'s functional standards. Aiming at evaluating the reproducibility of the performed tests, parameters were used with the respective criteria for the acceptance of the tests. The reproducibility criteria are indicators of accuracy. A comparison of these parameters was made with 50 tests performed in non-laryngectomized patients, in the same period with the same equipment, paired up according to age and gender. Results: In all cases of our study, an air-tight seal was maintained through the entire procedure with the use of the adhesive extra-tracheal device. After the performance of pulmonary function tests, 44% of patients presented a normal respiratory standard whereas 56% had an altered one. When comparing the frequency and percentage of the rejected tests between laryngectomized and control group, out of nine assessed parameters, five were exactly the same, three presented a greater rejection frequency in the control group and only one showed a greater frequency of rejected tests in the group of patients submitted to total laryngectomy. The total of rejected tests was greater in the control group (72%) when compared to the laryngectomized one (46%). Conclusions: Most patients submitted to total laryngectomy present altered pulmonary function, of the obstructive type most of the times, due to a smoking history. The methodology for the assessment of the pulmonary function by using the extra-tracheal proposed device is reliable, accurate and reproducible
|
79 |
Efeito da medida pré-operatória de força da musculatura respiratória no resultado do transplante de fígado / Effect of preoperative respiratory muscle strength on liver transplant outcome.Carla da Silva Machado 30 May 2007 (has links)
INTRODUÇÃO: Em pacientes com doença hepática avançada, pode ocorrer diminuição das pressões inspiratória máxima (PImáx) e expiratória máxima (PEmáx), respectivamente. Nos pacientes submetidos a transplante de fígado (Tx) essas alterações são agravadas no pós-operatório imediato. Para nosso conhecimento, a importância da medida pré-operatória da força da musculatura respiratória na evolução pós-operatória ainda não foi investigada no Tx. OBJETIVO: Avaliar o efeito das medidas pré-operatórias de força da musculatura respiratória no resultado do Tx. MÉTODO: Foram estudados retrospectivamente 228 pacientes de ambos os sexos, sem limite de idade, submetidos a primeiro Tx eletivo, com enxerto proveniente de doador cadáver. As medidas de PImáx e PEmáx foram obtidas imediatamente antes do transplante a partir do volume residual (VR) e da capacidade pulmonar total (CPT), respectivamente. Os pacientes foram classificados conforme a ocorrência de valores absolutos de pressão respiratória menores ou iguais a 50 cm H2O. As variáveis estudadas foram o tempo de ventilação mecânica pós-operatório, a necessidade de re-intubação orotraqueal ou de ventilação mecânica não-invasiva, o tempo de internação e a sobrevida dos pacientes. RESULTADO: Os resultados mostraram que os valores observados de PImáx e PEmáx estavam abaixo de 50 cm H2O em 19,7% (45/228) e 14,5% (33/228) dos pacientes, respectivamente. A freqüência de óbito até 6 meses após o transplante foi de 26/183 (14,2%) nos pacientes com PImáx > 50 cm H2O e de 15/45 (33,3%) nos pacientes com PImáx mais baixa (p=0,003). A sobrevida de 1, 3 e 5 anos foi 84%, 77% e 71% no grupo com PImáx > 50 cm H2O e 57%, 50% e 50% no grupo com PImáx mais baixa (p=0,0024). Em relação à PEmáx, essas probabilidades foram 80%, 74% e 69% no grupo com valores maiores que 50 cm H2O e 66%, 59% e 51% nos pacientes com força expiratória menor (p=0,1039). Não houve diferença estatisticamente significante em relação às demais variáveis analisadas. CONCLUSÃO: Pacientes com PImáx baixa apresentam maior mortalidade após o transplante de fígado. Entretanto, não foram encontrados efeitos estatisticamente significantes da medida pré-operatória da força da musculatura respiratória nas variáveis de resposta mais diretamente relacionadas com alterações respiratórias. / INTRODUCTION: Maximal inspiratory pressure (PImax) and maximal expiratory pressure (PEmax) were reduced in most patients with end-stage liver disease. In recipients of orthotopic liver transplantation (OLT), respiratory muscle weakness is worsened in the immediate postoperative period. In patients undergoing coronary artery bypass grafting, respiratory muscle weakness is associated with prolonged postsurgical mechanical ventilation and higher incidence of pulmonary complications. However, to our knowledge, no study has evaluated the effect of preoperative respiratory muscle strength on the postoperative course of OLT. AIM: To evaluate the effect of preoperative respiratory muscle strength on OLT outcome. METHODS: We reviewed 228 deceased donors elective OLT performed between 28th December, 1994 and 30th July, 2001. PImax e PEmax were assessed at residual volume and total lung capacity, respectively, immediately before OLT. Patients were classified according to the occurrence of muscle strength absolute values equal or lower than 50 cm H2O. The following response variables were analyzed: duration of postoperative mechanical ventilation, incidence of tracheal reintubation and noninvasive positive pressure ventilation, length of hospital stay and patient survival. RESULTS: PImax e PEmax were equal or lower than 50 cm H2O in 19.7% (45/228) and 14.5% (33/228) of patients, respectively. Patient mortality up to 6 months after OLT was 14.2% (26/183) in the group with PImax > 50 cm H2O and 33.3% (15/45) in the group with lower values (p=0.003). The 1-, 3-, and 5-year patient survival was 84%, 77% and 71% for the group with PImax > 50 cm H2O and 57%, 50% and 50% for the group with lower values (p=0.0024). In relation to PEmax, these probabilities were 80%, 74% e 69% for the group with higher values and 66%, 59% e 51% for patients with respiratory muscle weakness (p=0.1039). There is no significant difference regarding the others variables analyzed. CONCLUSION: Patients with low PImax present higher mortality after OLT. However, there are no statistically significant effects of the preoperative respiratory muscle strength on the response variables more directly related to the pulmonary outcome.
|
80 |
Avaliação da espirometria de gestantes expostas à poluição atmosférica da Região Metropolitana de São Paulo / Spirometric evaluation of pregnant women exposed to air pollution in the metropolitan region of São PauloLuciana Duzolina Manfré Pastro 11 March 2015 (has links)
Introdução: A poluição do ar pode levar a alterações no sistema respiratório, especialmente entre certos grupos, como as gestantes, que são mais vulneráveis aos efeitos de poluentes atmosféricos. A gravidez é um período que envolve alterações funcionais e anatômicas no corpo da mulher, incluindo alterações na função pulmonar, o que pode ser avaliado por espirometria, um método simples, barato e eficaz. Objetivos: Os objetivos deste estudo foram a usar a espirometria para avaliar a função pulmonar de mulheres no primeiro trimestre (T1) e no terceiro trimestre (T3) de gravidez e analisar a influência da exposição a poluição do ar sobre os parâmetros espirométricos. Metodologia: O estudo foi realizado no Ambulatório de Obstetrícia do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP) entre Maio de 2011 e Agosto de 2013. Foram aplicados os seguintes critérios de inclusão: gestação única, idade gestacional no dia da primeira espirometria inferior a 13,86 semanas, ausência de doenças maternas préexistentes, preparação adequada para o teste de espirometria e amostradores passivos individuais (APIs) adequados para análise. Os critérios de exclusão foram a mudança de endereço, o aborto, o teste de espirometria inadequado e desistência de participar do projeto. Os APIs contendo dois filtros de celulose embebidos com solução absorvente para capturar os níveis de NO2 e outros dois filtros embebidos com solução de índigo blue para medir os níveis de O3 foram entregues às gestantes cerca de 12 dias antes da realização do teste de espirometria. Dados do relatório anual da Companhia Ambiental do Estado de São Paulo (CETESB) para o mesmo período dos amostradores passivos, foram utilizados. Para a espirometria, um espirômetro Koko foi utilizado, sendo considerada as duas melhores curvas para avaliar os resultados da função pulmonar. Análise estatística: Foi utilizado o teste Mann-Whitney para grupos independentes e Wilcoxon para os dependentes. Devido à pequena variação na exposição à poluição, a exposição no primeiro trimestre (Q1) e quarto trimestre (Q4) foram comparados para cada poluente em T1 e T3 através da análise nãoparamétrica para medidas repetidas. Resultados: Houve uma redução estatisticamente significativa dos valores absolutos (T1: 3,690 L; T3: 3,475 L) e preditos (T1: 101%, T3: 97,5%) da capacidade vital forçada (CVF), p < 0,0001. E uma redução estatisticamente significativa dos valores absolutos (T1: 3.080 L; T3: 2.950 L) e preditos (T1: 99%, T3: 96%) do volume expiratório forçado no primeiro segundo do procedimento (FEV1), p < 0,0001. A exposição à poluição foi semelhante em ambos os trimestres, exceto para a exposição de NO2 no API, o que foi inferior em T3 (p = 0,001). Independentemente do trimestre (T1 ou T3), o grupo de mulheres do Q4 (T1: 97,5%; T3: 98,5%) teve NO2 estatisticamente maior dos valores do fluxo expiratório forçado de 25 a 75% do procedimento (FEF25-75%) do que o grupo em Q1 (T1: 80%; T3: 92%). O grupo de mulheres do Q1 do NO2 teve um aumento significativo neste parâmetro de T1 a T3 (p = 0,042). Em termos de valores absolutos da relação FEV1/FVC, o grupo de mulheres no Q1 mostrou um aumento estatisticamente significativo neste parâmetro de T1 (0,810 L) para T3 (0,840 L) (p = 0,026). Em T3, os valores absolutos e relativos da CVF foram estatisticamente maiores para o grupo de gestantes do Q4 (3,535 L; 100,5%) de NO2 do que para o grupo de gestantes do Q1 (3,345 L; 92%). O grupo de gestantes do Q4 de O3 mostrou o VEF1 estatisticamente maior eno T1 (102,5%) do que no T3 (95,5%) (p < 0,001). Independentemente do trimestre, o grupo de gestantes do Q4 do MP10, teve valores absolutos da CVF (T1: 3.520 L; T3: 3,265 L) e os valores de VEF1 (T1: 2,915 L; T32.840 L) foram estatisticamente menor do que para o grupo em Q1 (FVC - T1: 3.780 L; T3: 3.580 L) (FEV1 - T1: 3.180 L; T3: 3.065 L) p = 0,040; p = 0,035, respectivamente. Valores absolutos e preditos do pico de fluxo expiratório (PEF) em T1 das mulheres do Q4 (5,995 L; 80%) do MP10 foram estatisticamente menores do que para as mulheres no Q1 (6,675 L; 85%) (p = 0,006; p = 0,041 , respectivamente). Mulheres grávidas em Q4 (0,835 L) do MP10 tiveram os valores da relação VEF1/CVF estatisticamente menores valores do que as mulheres do Q1 (0,850 L) (p = 0,029). Conclusão: Exposição a NO2 e O3 foi associada com o aumento de alguns dos parâmetros de espirometria, indicando a presença de uma possível função de defesa pulmonar ou mecanismo compensatório em mulheres grávidas, quando expostos a esses poluentes. O MP10 foi associado com a redução de alguns parâmetros de espirometria durante a gravidez, indicando os efeitos danosos do poluente para a função do pulmão de mulheres grávidas / Introduction - Air pollution can lead to alterations to the respiratory system, particularly among certain groups, such as pregnant women, which are more vulnerable to the effects of air pollutants. Pregnancy is a period involving functional and anatomical changes in a woman\'s body. These changes include pulmonary function, which can be assessed by spirometry, a simple, inexpensive and effective method. Objectives - The aims of this study were to use spirometry to evaluate pulmonary function in pregnant women in the first trimester (T1) and the third trimester (T3) of pregnancy and to analyze the influence of air pollution exposure on the spirometry parameters. Methodology - This study was carried out at the Obstetrics Clinic of Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP) between May 2011 and August 2013. The following inclusion criteria were applied: singleton pregnancy, 13.86 weeks gestational age at the first spirometry, no preexisting maternal diseases, adequate preparation for the spirometry test and individual passive samplers (IPAs) suitable for analysis. The exclusion criteria were change of address, abortion, inadequate spirometry testing and withdrawal from the project. The exposure to pollutants prior to the spirometry tests was assessed in T1 and T3. The passive samplers containing two cellulose filters soaked with absorbent solution to capture NO2 levels and two other filters soaked with indigo solution to measure O3 levels were provided to the pregnant women roughly 12 days prior to the spirometry test. Data from the environmental Company of São Paulo State (CETESB) annual report for the same period the passive samplers were used. For the spirometry, a Koko spirometer was used, taking the two best curves to assess lung function results. Statistical Analysis - We used Mann- Whitney tests for independent groups and Wilcoxon for the dependent ones. Due to the small variation in the exposure to pollution, exposure in the first quarter (Q1) and fourth quarter (Q4) were compared for each pollutant in T1 and T3 through non-parametrical analysis for repeated measurements. Results - It has been noted a significant statistical reduction of absolute and predicted forced vital capacity (FVC) values (3.690 L; 3.475 L) and forced expiratory volume during the first second of the procedure (FEV1) (3.080 L; 2.950 L) from T1 to T3. Exposure to pollution was similar in both trimesters, except for exposure to NO2 in the passive sampler, which was lower in T3 (p = 0.001). Regardless of the trimester (T1 or T3), the group of pregnant women in Q4 (97.5%; 98.5%) of NO2 had statistically higher predicted forced expiratory values of 25 to 75% of the procedure (FEF25-75%) than the group in Q1 (80%; 92%). Pregnant women in Q1 of NO2 had a significant increase in this parameter from T1 to T3 (p = 0.042). In terms of absolute FEV1/FVC values, pregnant women in Q1 showed a statistically significant rise in this parameter from T1 (0.810 L) to T3 (0,840 L) (p = 0,026). In T3, absolute and predicted FVC values were statistically higher for the group of pregnant women in Q4 (3.535 L; 100.5%) of NO2 than for the group of pregnant women in Q1 (3.345 L; 92%). Pregnant women in Q4 of O3 displayed statistically higher FEV1 values in T1 (102.5%) than in T3 (95.5%) (p < 0.001). Regardless of trimester, for the group of pregnant women in Q4 of MP10, absolute FVC (T1:3 .520 L; T3: 3.265 L) and FEV1 values (T1: 2.915 L; T3: 2.840 L) were statistically lower than for the group in Q1 (FVC - T1: 3.780 L; T3: 3.580 L) (FEV1 - T1: 3.180 L; T3: 3.065 L) p = 0.040; p = 0.035 respectively. Absolute and predicted peak expiratory flow (PEF) in T1 of pregnant women in Q4 (5.995 L; 80%) of MP10 were statistically lower than for the pregnant women in Q1 (6.675 L; 85%) (p = 0.006; p = 0.041, respectively). Pregnant women in Q4 (0.835 L) of MP10 displayed statistically lower absolute FEV1/FVC values than the pregnant women in Q1 (0.850 L) (p = 0.029). Conclusion - Exposure to NO2 and O3 was associated with the increase in some of the spirometry parameters, indicating the presence of a possible lung function defense or compensatory mechanism in pregnant women when exposed to those pollutants. The MP10 was associated with the reduction of some spirometry parameters during pregnancy, indicating the harmful effects of that pollutant to the lung function of pregnant women
|
Page generated in 0.1102 seconds