• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 108
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 1
  • Tagged with
  • 110
  • 110
  • 48
  • 31
  • 27
  • 24
  • 23
  • 22
  • 19
  • 18
  • 17
  • 15
  • 14
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Sobrevivência de restaurações e facetas de resina composta direta e cerâmicas em dentes anteriores: estudo retrospectivo sobre fatores relacionados à substituição e ao reparo / Survival of direct composites restorations, veneers and ceramic veneers in anterior teeth: $b retrospective study of factors related to the replacement and repair

Patias, Rômulo 28 February 2015 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-06-21T11:39:45Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Sobrevivência de restaurações e facetas de resina composta direta e cerâmicas em.pdf: 713192 bytes, checksum: 02a79da83ee80cb1eea340e87092b4dc (MD5) / Made available in DSpace on 2017-06-21T11:39:45Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Sobrevivência de restaurações e facetas de resina composta direta e cerâmicas em.pdf: 713192 bytes, checksum: 02a79da83ee80cb1eea340e87092b4dc (MD5) Previous issue date: 2015-02-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / A avaliação da sobrevivência de restaurações em dentes posteriores tem sido bastante explorada na literatura recente, no entanto, poucos estudos foram encontrados sobre a longevidade de restaurações em dentes anteriores. O presente estudo avaliou a longevidade de restaurações e facetas de resina composta direta e facetas cerâmicas em dentes anteriores, investigando alguns fatores relacionados à falha e ao reparo destas restaurações. O desenho do estudo foi do tipo longitudinal retrospectivo, realizado por meio da coleta de dados dos arquivos de um consultório privado. Para inclusão, os pacientes deveriam ter recebido restaurações em dentes anteriores, em resina composta ou facetas cerâmicas, e ter permanecido em acompanhamento na mesma clínica odontológica, o período incluído na avaliação foi de 1994 até 2014. As restaurações e avaliações foram realizadas por um único operador. A avaliação dos dados coletados foi dividida em duas etapas. Na primeira parte do estudo, resinas compostas com 5 a 20 anos de acompanhamento foram selecionadas. Os fatores em estudo foram o sexo do paciente, o tipo de resina composta (Híbrida, Microhíbrida, e associação Microparticulada e Híbrida), o arco (superior e inferior), o dente (incisivo central, incisivo lateral e canino), e o tipo de cavidade (classe III e IV e faceta). Os desfechos avaliados foram às intervenções realizadas (reparo ou substituição das restaurações) e taxa de falha anual (considerando reparo ou substituição como falha). As análises estatísticas foram realizadas com testes Qui-quadrado, análise de sobrevivência pelo método Kaplan- Meier e Regressão de Cox. A segunda parte do estudo incluiu as restaurações do tipo faceta com tempos de acompanhamento de até 4 anos, realizadas em resina composta nanohíbrida/nanoparticulada e cerâmicas, no período de 2009 até 2013. Apenas estatística descritiva pôde ser utilizada. No total, 123 pacientes foram incluídos, e 524 restaurações foram avaliadas na primeira parte. Diferenças significativas para substituição das restaurações foram encontradas entre os arcos dentários, com arco superior tendo maior taxa de falha em relação ao inferior, após 10 anos de acompanhamento, apresentavam uma taxa de sobrevivência de 41% e 73% de sobrevivência, respectivamente. Sobre os reparos, diferenças significativas foram encontradas de acordo com o material utilizado e o tipo de restauração, com as resinas microhíbridas apresentando maior quantidade de reparos em relação às híbridas e a associação micropartículadas mais híbridas, entretanto com maior sobrevivência em relação as outras. Foram encontradas maiores frequências de reparo, entre os tipos de restauração realizada, com facetas apresentando maior quantidade de reparos em relação às restaurações classe III e IV. Na segunda parte do estudo, na comparação de facetas diretas e indiretas, 155 facetas foram avaliadas, apenas estatística descritiva foi utilizada, não foram encontradas diferenças entre as técnicas com relação a substituição e reparo das facetas com 7 até quatro anos de acompanhamento, apesar das cerâmicas apresentarem maior quantidade de substituição e reparos. Mesmo com as limitações do presente estudo, se conclui que estética pode ser a principal causa para falhas das restaurações em dentes anteriores, restaurações nos dentes superiores apresentaram maior número de intervenções em relação aos inferiores. Já com relação a comparação entre facetas, as técnicas direta e indireta apresentaram resultados semelhantes e satisfatórios com quatro anos de acompanhamento, entretanto um maior número de facetas e maior tempo de acompanhamento é necessário para evidenciar maiores diferenças. / The evaluation of restorations survival in posterior teeth has been quite explored in the recent literature, however, few studies were found on the longevity of restorations in anterior teeth. This study evaluated the longevity of direct composite restorations, direct veneers and ceramic veneers in anterior teeth, investigating factors related to failure and repair of these restorations. The study design was a retrospective longitudinal, conducted by collecting data from the files of a private office. For inclusion, patients should have received restorations in anterior teeth, composite resin or ceramic veneers, and have remained in the same monitoring dental practice, the period included in the review was from 1994 to 2014. The restorations and evaluations were performed by a single operator. The data evaluation was divided into two stages. In the first part of the study, composites with 5-20 years of follow-up were selected. The factors were sex of the patient, the type of composite resin (hybrid, microhybrid, and microfilled and Hybrid association), the arch (upper and lower), the tooth (central incisor, lateral incisor and canine), and type cavity (Class III and IV and facet). The outcome measures were the interventions (repair or replacement of restorations) and annual failure rate (considering repair or replacement as failure). Statistical analyzes were performed using chi-square tests, survival analysis using the Kaplan-Meier method and Cox regression. The second part of the study included the veneer restorations with follow-up times of up to four years, held in composite nanohybrid / nanofilled and ceramics, from 2009 until 2013. Only descriptive statistics could be used. In total, 123 patients were enrolled, and 524 restorations were evaluated in the first part. Significant differences for replacement of restorations were found between dental arches, with upper arch with higher failure rate compared to lower, after 10 years of follow-up, showed a survival rate of 41% and 73% survival, respectively. About repairs, significant differences were found according to the material used, the tooth and the type of restoration, with microhybrids resins possessing a larger amount of repairs in the relation of hybrid and more hybrid microparticulate association, however with greater survival in relation to the other. Greater frequency of repair were found between the types of restoration was carried out, with veneers having greater amount of repairs in relation 9 to restorations class III and IV. In the second part of the study, compared direct and indirect veneers, 155 facets were evaluated, only descriptive statistics were used, there were no differences between the techniques regarding the replacement and repair of the facets with up to four years of follow-up, despite the ceramics evaluated have a higher amount of replacement and repairs. Even with the limitations of this study, that possible conclude that aesthetics can be the main cause for failure of restorations in anterior teeth, restorations on the upper teeth had a greater number of interventions in relation to the lower. In relation to comparison of veneers, the direct and indirect techniques had similar and satisfactory results with four year follow-up, however a greater number of facets and longer follow-up is necessary to highlight the major differences.
52

Reparo em restaurações de resina composta : longevidade clínica e relevância para a odontologia / Repair composite restorations : clinical longevity and relevance to dentistry

Elias, Raquel Viégas 27 February 2016 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-06-21T13:31:35Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Reparo em restaurações de resina composta longevidade clínica e.pdf: 1079352 bytes, checksum: 9f6c511706af8ca0bce89d106f58b972 (MD5) / Made available in DSpace on 2017-06-21T13:31:35Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Reparo em restaurações de resina composta longevidade clínica e.pdf: 1079352 bytes, checksum: 9f6c511706af8ca0bce89d106f58b972 (MD5) Previous issue date: 2016-02-27 / Sem bolsa / O reparo de restaurações com falhas é uma das alternativas de tratamento indicadas por preservar o máximo de tecido dentário sadio. É de fácil execução, baixo custo, confortável para o paciente e capaz de aumentar a longevidade da restauração e do dente. Apesar disso, ainda é pouco utilizado pelos dentistas como alternativa à substituição de restaurações com defeitos. Dúvidas persistem com relação ao protocolo clínico e a longevidade desse procedimento. Este trabalho objetiva revisar na literatura aspectos relevantes sobre reparo em restaurações de resina composta e avaliar, através de um estudo clínico, a influência do reparo sobre a sobrevivência de restaurações de resina composta em dentes anteriores, com acompanhamento de 4 a 15 anos. A revisão foi do tipo narrativa e através das principais bases de dados foram selecionados estudos clínicos prospectivos ou retrospectivos e revisões sistemáticas ou narrativas sobre reparo de restaurações em resina composta. Para o estudo clínico utilizou-se um banco de dados extraídos de 396 prontuários de pacientes atendidos em uma clínica odontológica privada que receberam 628 restaurações de resina composta do tipo híbrida, microhíbrida e microparticulada em dentes anteriores, realizadas entre os anos de 1994 e 2009. Do total de restaurações foram realizados 198 reparos (55 classes III/IV; 143 facetas), dos quais 36 (65.4%) e 91(63.6%), respectivamente, em classes III/IV e facetas, permaneceram íntegros durante o período de avaliação. A sobrevivência das restaurações reparadas foi o desfecho principal do estudo. O teste exato de Fisher foi utilizado para analisar as diferenças nas falhas dentro de cada categoria (a=0.05). O método Kaplan-Meier foi empregado para gerar as curvas de sobrevivência em 15 anos. Regressão de Cox multivariável permitiu investigar a influência das variáveis de interesse (gênero, arco, lado, tipo de dente, tipo de resina composta e cavidade) na sobrevivência das restaurações. A taxa de falha anual das restaurações de classes III e IV, quando o reparo foi considerado sucesso, foi de 3.2% após 15 anos de acompanhamento, subindo para 4.9% quando o reparo foi considerado falha. Para facetas, a taxa de falha anual foi de 10.4% após 10 anos quando o reparo foi considerado sucesso e de 17.8% quando o reparo foi considerado falha. O arco dentário interferiu significativamente na longevidade das restaurações, com taxa de sobrevivência maior quando inseridas no arco inferior. Restaurações realizadas nos incisivos centrais apresentaram significativamente taxa de sobrevivência menor em relação aos incisivos laterais e caninos, exceto quando o reparo foi considerado sucesso em classes III e IV. As facetas realizadas com a associação de uma resina microhíbrida com uma microparticulada, quando o reparo foi considerado sucesso, tiveram maior sobrevivência em relação às realizadas apenas com resinas microhíbridas. Nossos achados com tempo longo de acompanhamento indicam que o reparo em restaurações de resina composta realizadas em dentes anteriores aumenta significativamente a sobrevivência das restaurações sendo uma alternativa viável para o tratamento de restaurações de resina composta com falhas. No entanto, estudos que levem em consideração a causa de falha da restauração, reparo ou substituição e hábitos de vida do paciente são necessários. / The repair of restorations is one of the alternative treatment indicated to preserve healthy tooth tissue. It is a procedure easy to perform, inexpensive, comfortable for the pacient and able of extending the longevity of the restorations and the tooth. However, it is still very little used by dentists as an alternative to replacement of defective restorations. There are still doubt regard the clinical protocol and longevity of this procedure. This study reviewed in the literature relevant aspects of repair in composite restorations and evaluate, through a retrospective clinical study the influence of repair on the survival of composite restorations in anterior teeth with follow-up time of 4 to 15 years. The review narrative selected in the main databases were select prospective and retrospective clinical studies and systematic reviews or narratives about restorations repair in composite. For the clinical study used a database extracted from 396 records of 138 patients seen at a private dental clinical with 628 composites restorations hybrid, mycrohibrid and microfillin anterior teeth carried between the years 1994 and 2009. The survival of repaired restorations was the main outcome of the study. The Fisher’s exact test was used to analyze the differences in failures within each category (a=0.05). Kaplan-Meier method was used to generate survival curves at 15 years. A multivariate Cox regression analysis was used to investigate the influence of the variables of interest (material, age, gender, jaw, tooth, side, cavity) in restoration survival. In all restorations were performed 198 (55 classes III/IV, 143 facets) repairs, of which 36 (65.4 %) and 91 (63.6 %), respectively, in classes III / IV and veneers, remained intact during the evaluation period. The repair interfered significantly in the survival of restorations. Annual failure rate percentage of class III/IV restorations, when repair was considered successful was 3.2% up to 15- years of follow-up, increased to 4.9% when the repair was considered failure. Annual failure rate percentage for veneers was 10.4% after 10 years when repair was considered successful and 17.8% when repair was regarded as failed. The arch interfered significantly in longevity restorations with higher survival rate when fulfilled in the lower arch. Restorations in the central incisors had significantly lower survival rate compared to the lateral incisors and canines, except when the repair was considered successful in class III and IV. The type of resin influenced the survival of the restorations when the repair was considered successful. Restorations class III/IV with hybrid composite resin had a higher survival rate compared to microhybrid and hybrid, while for the veneers microfill resins presented higher survival rates than microhybridan hybrid composites. Our findings with long follow-up indicate that the repair in composite restorations in anterior teeth significantly increases the survival of restorations being a viable alternative to treatment failures in composite restorations. However, studies that take into account the cause of failure of restoration, repair or replacement and patient lifestyle habits are needed.
53

Restauração de lesões cervicais não cariosas : fatores relacionados a sua sobrevivência e impactos periodontais / Restoration of non-carious cervical lesions : factors related to their survival and periodontal impacts

Favetti, Morgana 21 February 2017 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-07-06T12:46:22Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Restauração de lesões cervicais não cariosas fatores relacionados a sua.pdf: 2783824 bytes, checksum: 45300011c17936be2f00f1beb459371e (MD5) / Made available in DSpace on 2017-07-06T12:46:22Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Restauração de lesões cervicais não cariosas fatores relacionados a sua.pdf: 2783824 bytes, checksum: 45300011c17936be2f00f1beb459371e (MD5) Previous issue date: 2017-02-21 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / O presente estudo teve como objetivo avaliar os aspectos de sobrevida de restaurações diante das intervenções propostas por dois ensaios clínicos randomizados com tempos de acompanhamento diferentes, um com 36 meses e outro com 60 meses. Adicionalmente, objetivou-se avaliar a condição periodontal de pacientes que receberam restaurações em lesões cervicais não cariosas (LCNC) nestes estudos. O estudo com 36 meses de acompanhamento (Número de pacientes - Np = 42; Número de restaurações -Nr= 182), foi realizado com 3 diferentes grupos, nos quais aplicavam-se diferentes soluções (controle - solução placebo, experimental 1 - solução de clorexidina 2%, e experimetal 2 - solução de hipoclorito de sódio 10%) durante 60 segundos após o condicionamento ácido e antes da aplicação do adesivo e da restauração das LCNC. Sendo assim, este primeiro estudo deu origem à 2 estudos (estudo 1 e 2), respectivamente sobre os efeitos do pré-tratamento com CHX 2% e NaOCl 10% na retenção de restaurações em LCNCs. O estudo com 60 meses de acompanhamento (Np = 36; Nr = 172) deu origem ao estudo 3, sendo que este foi desenvolvido para avaliar o efeito de diferentes formas de isolamento do campo operatório (isolamento absoluto - com dique de borracha e grampo, ou isolamento relativo - com fio retrator, afastador labial, e ambos com sugador de saliva) para a realização de restaurações de LCNC. Um avaliador experiente, treinado e calibrado em cada um dos dois grandes estudos, avaliou as restaurações após 6, 12, 24, 36 ou 60 meses utilizando os critérios da FDI. Para a avaliação periodontal, um mesmo avaliador, padrão ouro, para ambos os estudos, avaliou os casos seguindo critérios pré-estabelecidos. Outro pesquisador comparou as informações obtidas com as já existentes nas fichas clínicas dos pacientes com as que foram obtidas no exame clínico e na aplicação do questionário realizados nos últimos recalls de cada estudo, de 3 ou 5 anos. A união dos dados periodontais oriundos das duas amostras, deu origem à um quarto estudo, que representa a associação entre os aspectos relacionados às restaurações (nível da margem e tipo de isolamento) e os tecidos periodontais adjacentes. Os resultados demostraram que a utilização de diferentes soluções, como clorexidina 2% ou hipoclorito de sódio 10%, durante o processo restaurador, bem como o tipo de isolamento realizado durante a execução do tratamento restaurador, não influenciaram a taxa de sobrevida das restaurações de LCNC ao longo do tempo. Ainda, do ponto de vista periodontal, o tipo de isolamento e a presença das restaurações não demonstraram gerar dano aos critérios periodontais avaliados após acompanhamento de 36 ou 60 meses. Houve relevante associação de determinadas características das lesões e dos pacientes com as taxas de falhas das restaurações. / The present study had as objective to evaluate the survival aspects of restorations before the interventions proposed by two randomized clinical trials with different times of follow-up, one with 36 months and another with 60 months. Additionally, the aim of this study was to evaluate the periodontal condition of patients who received non-carious cervical lesion restorations (NCCL) in these studies. The study with 36 months of follow-up (Number of patients - Np = 42; Number of restorations -Nr = 182) was performed with 3 different groups, in which different solutions were applied (control - placebo solution, experimental 1 - solution of Chlorhexidine 2%, and experimental 2 - 10% sodium hypochlorite solution) for 60 seconds after acid etching and before application of the adhesive and restoration of NCCL. Thus, this first study gave rise to two studies (study 1 and 2), respectively, on the effects of pretreatment with CHX 2% and NaOCl 10% on the retention of NCCL restorations. The study with 60 months of follow - up (Np = 36; Nr = 172) gave rise to study 3, which was designed to evaluate the effect of different forms of isolation of the operative field (absolute isolation - with rubber dam and clamp, Or relative insulation - with retractor wire, lip retractor, and both with saliva succion) for performing NCCL restorations. An experienced, trained and calibrated evaluator in each of the two large studies evaluated the restorations after 6, 12, 24, 36 or 60 months using the FDI criteria. For the periodontal evaluation, the same gold standard evaluator for both studies evaluated the cases according to pre-established criteria. Another researcher compared the information obtained with the already existing ones in the clinical records of the patients with those obtained in the clinical examination and in the application of the questionnaire carried out in the last recalls of each study, of 3 or 5 years. The union of the periodontal data from the two samples gave rise to a fourth study, which represents the association between aspects related to restorations (margin level and type of isolation) and adjacent periodontal tissues. The results demonstrated that the use of different solutions, such as 2% chlorhexidine or 10% sodium hypochlorite, during the restorative process, as well as the type of isolation performed during the restorative treatment, did not influence the survival rate of NCCL over time. Also, from the periodontal point of view, the type of insulation and the presence of the restorations did not show damage to the periodontal criteria evaluated after 36 or 60 months follow up. There was a relevant association between certain characteristics of the lesions and the patients with the failure rates of the restorations.
54

Influência da contaminação pela fumaça do cigarro na resistência de união entre dentina e resina composta utilizando-se dois sistemas adesivos

Almeida, Adriano Gondim 25 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2010 / Made available in DSpace on 2012-10-25T05:17:35Z (GMT). No. of bitstreams: 1 284786.pdf: 2195904 bytes, checksum: d141ab609b863db645cb4e5b08a594f0 (MD5) / O objetivo deste estudo, in situ, foi avaliar a influência da fumaça do cigarro na resistência de união entre a resina composta e a dentina. Doze voluntários foram divididos em 3 grupos de 4 indivíduos: Grupo Controle, não fumantes; Grupo F10, voluntários que fumam aproximadamente 10 cigarros por dia; e Grupo F20, voluntários que fumam aproximadamente 20 cigarros por dia. Cada voluntário utilizou, por 20 dias, um dispositivo intraoral que continha hemidiscos de dentina fixados na porção palatal de acrílico, com a superfície voltada para a cavidade oral. Posteriormente, os hemidiscos foram removidos do dispositivo e restaurados com resina composta (Z350, 3M ESPE) utilizando o sistema adesivo Adper Scotchbond Multi-Uso (condicionamento total de três passos) ou o Clearfil SE Bond (autocondicionante de dois passos). Os hemidiscos restaurados foram submetidos a cortes sequenciais para se obterem filetes com área de secção transversal de aproximadamente 0,8 mm2 para ensaio de microtração, ao qual foram submetidos posteriormente com velocidade de travessa de 0,5 mm/min. Hemidiscos representativos de cada grupo foram analisados em microscópio eletrônico de varredura (MEV), revelando remoção parcial da lama dentinária após condicionamento ácido total, o que poderia oferecer maior resistência ao condicionamento ácido total. A análise estatística dos resultados (Testes t de Student) mostrou que a fumaça do cigarro não influenciou significativamente os valores de adesão ao se utilizar o Scotchbond Multi-Uso, mas, ao se utilizar o sistema adesivo autocondicionante Clearfil SE Bond, os valores reduziram-se significativamente. Pode-se concluir que a contaminação pela fumaça do cigarro interferiu na resistência de união à dentina ao se utilizar o sistema adesivo autocondicionante e que, diante de uma dentina contaminada por fumaça do cigarro, o sistema adesivo de condicionamento total de três passos apresentou melhor desempenho.
55

Avaliação clínica da intensidade da força máxima friccional dos contatos proximais de restaurações diretas e indiretas em dentes posteriores

Stolf, Sheila Cristina January 2011 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-26T04:52:29Z (GMT). No. of bitstreams: 1 300453.pdf: 314520351 bytes, checksum: 33a6b2f61f87a1bf9e9d6b1f6cb12ae0 (MD5) / O objetivo deste trabalho clínico é determinar e comparar o contato proximal estabelecido por restaurações diretas e indiretas do tipo mésio-oclusodistais (MOD) em dentes posteriores. Selecionaram-se 36 pacientes, os quais receberam restaurações diretas de resina composta ou indiretas de cerâmica. As restaurações foram confeccionadas com o sistema adesivo Scotchbond Multi-Purpose e resina composta FiltekTM Z350 (n=18) e com cerâmica injetável IPS e.max Press (n=18). Os contatos proximais foram mensurados por meio do aparelho Medidor de Pressão Dental (TPM), antes do tratamento e 48 h após a confecção das restaurações entre os contatos proximais, mesial e distal, do dente restaurado e os do dente adjacente (CPMR e CPDR, respectivamente), assim como o contato proximal mesial do dente adjacente à restauração (CPM). Como controle, mensuraram-se os contatos proximais no lado contralateral, nas mesmas posições de mensuração. Após a realização das ANOVAs ou ANCOVAs, utilizou-se o Teste post hoc de Bonferroni. A comparação dos valores iniciais e finais da força máxima friccional (FMF) em cada grupo, para cada posição, foi realizada por meio do Teste t de Student (p?0,05). Para os valores finais de FMF entre os grupos verificou-se que na posição de contato proximal distal do dente restaurado (CPDR) as médias obtidas no grupo submetido ao tratamento restaurador com cerâmica e as do grupo controle foram consideravelmente diferentes, porém não diferiram naqueles contatos submetidos à resina composta. Quanto à posição contato proximal mesial (CPMR and CPM), independentemente do local de mensuração, verificaram-se diferenças estatísticas significativas entre todos os grupos (p<0,001), com destaque para a cerâmica. Portanto, a FMF do contato proximal promovido pelas restaurações diretas e indiretas variou, respectivamente, na posição mesial do dente restaurado entre 1,53 N e 2,70 N e entre 1,47 N e 5,07 N, e na posição distal restaurada, de 1,63 N a 2,07 N e de 1,03 N a 4,50 N. As restaurações cerâmicas promoveram contatos proximais mais justos em relação às resinas compostas. Ainda, as restaurações aumentaram a FMF do contato proximal mesial do dente adjacente à restauração, entretanto nos contatos proximais do lado contralateral constatou-se pouca interferência
56

Avaliação da infiltração marginal de compósitos de baixa contração e convencional, sob diferentes técnicas de fotoativação

Alexandre, Pedro 26 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2011 / Made available in DSpace on 2012-10-26T05:22:04Z (GMT). No. of bitstreams: 1 297390.pdf: 1598843 bytes, checksum: 6474f3887b9ea0510ef58328e206ccf9 (MD5) / Como material de reposição de estrutura dental perdida, as resinas compostas vêm sendo utilizadas ao longo do tempo com relativo sucesso. Entretanto, ainda apresentam limitações, ligadas especialmente às suas características físico-químicas e às dificuldades da técnica. Dentre as limitações das resinas, a contração, quando da reação de formação das cadeias poliméricas, pode ser responsável por alguns problemas como a microinfiltração marginal. Outros fatores, como técnica de inserção e fotoativação, fator C, coeficiente de expansão térmica linear e tipo de resina, são também associados a esse problema. Este trabalho avaliou se a resina FiltekTM P90, com monômero resinoso silorano, o qual promete menos contração de polimerização, resulta em menor microinfiltração que a resina FiltekTM Z350, baseada em metacrilatos convencionais. Além disso, foi avaliado se a técnica do pulso tardio promove menos infiltração. Foram preparadas 60 cavidades de classe II em 30 terceiros molares extraídos por razões alheias à pesquisa. As restaurações foram realizadas de acordo com instruções do fabricante. Após preparo e impermeabilização dos espécimes, eles foram imersos em solução de Rodamina B 0,2%, por 24hrs, para avaliar a microinfiltração. Os dados foram analisados estatisticamente pelo teste exato de Fischer com (p=0,05) e n=120. Das 120 margens avaliadas 99 não apresentaram infiltração, enquanto 21 sim. Destas 21 infiltrações, 3,3% ocorreram com FiltekTM P90 e 31,7% com a resina FiltekTM Z350. Pode-se observar que a resina FiltekTM P90 foi capaz de reduzir a infiltração marginal em restaurações de classe II, e que a técnica de pulso tardio não exerceu influência na infiltração marginal. / As a restorative dental material to replace the lost dental structure, the composite resin have been used overtime with relative success. However, they still have limitations, especially relating to their physical and chemical characteristics and difficulties of the technique. Among the limitations of the resins, the contraction during the formation reaction of the polymer chains may be responsible for some problems, including microleakage. Other factors such as light curing, insertion technique, C-factor, coefficient of linear thermal expansion and resin type are also associated with this problem. This study evaluated if FiltekTM P90, with silorane resin monomer, which promises less polymerization shrinkage, results in less microleakage than FiltekTM Z350 methacrylate based resin. Additionally was tested if the Pulse Delay technique promotes less rate of infiltration. Sixty class II cavities were prepared in thirty molars extracted for reasons unrelated to the research, and restored in accordance with the manufacturer. After preparation the specimens were covered with nail varnish, they were immersed in 0.2% Rhodamine B for 24hrs to evaluated the microleakage. The data were statistically analyzed by Fischer Exact with (p=0,05) and n=120. There isn#t infiltration for 99 specimens and positive infiltration for 21. Of these 21 infiltration FiltekTMP90 had 3.3% of the infiltrations and FiltekTMZ350 had the others 31.7%. It can be observed that the resin FiltekTM P90 was able to reduce infiltration in Class II restoration, and the pulse delay technique had no influence on infiltration.
57

Influência da reprodução da junção amelo-dentinária no comportamento óptico de restaurações com compósitos

Ferreira, Isana Álvares January 2006 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-22T22:21:20Z (GMT). No. of bitstreams: 1 239077.pdf: 25988956 bytes, checksum: ffe95ab29f0f55399ad189111a8a0b65 (MD5) / Esse estudo avaliou a influência da aplicação de uma resina específica para reprodução da junção amelo-dentinária (JAD) nas propriedades ópticas de restaurações com compósitos. Blocos de resina com 4mm de espessura, formados por 3 discos de resina correspondentes ao esmalte vestibular, dentina e esmalte palatal, foram confeccionados. Esses blocos foram divididos em 2 grupos, de acordo com a resina composta utilizada para sua confecção: grupo A (n=30), resina Vit-l-escence (Ultradent) e grupo B (n=30), resina 4 Seasons (Ivoclar Vivadent). Cada grupo foi subdividido em 5 subgrupos (n=6), de acordo com a reprodução ou não da JAD: subgrupo 1, sem reprodução da JAD; subgrupo 2, reprodução da JAD vestibular (V) com DE Connector (Ultradent); subgrupo 3, reprodução da JAD V e Palatina (P) com DE Connector; subgrupo 4, reprodução da JAD V com Single Bond (3M ESPE); e subgrupo 5, reprodução da JAD V e P com Single Bond. Os corpos-de-prova foram analisados no espectrofotômetro para avaliação da reflexão, luminosidade (coordenada L*) e fluorescência. Os resultados foram submetidos ao teste estatístico de análise de variância, teste de Tukey e Kruskal Wallis. Os valores de reflexão e L* aumentaram quando o DE Connector foi aplicado, sem diferença estatisticamente significativa entre os subgrupos A2 e A3; e B2 e B3. Os valores de fluorescência não foram influenciados pela aplicação do DE Connector. A reprodução da junção amelo-dentinária vestibular, através da aplicação do DE Connector, é suficiente para alterar as propriedades ópticas das restaurações dos compósitos, elevando a reflexão 13 e luminosidade. Entretanto, o adesivo Single Bond, não reproduziu as propriedades ópticas da JAD, e, portanto, não deve ser utilizado para essa finalidade.
58

Teste mecânico de compósitos indiretos aplicados diretamente sobre abutments implanto-suportados

Andriani Júnior, Wilson January 2007 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-23T01:48:19Z (GMT). No. of bitstreams: 1 248356.pdf: 800328 bytes, checksum: 2cbd10e89943f6262ee950f18f7b0fee (MD5) / O objetivo deste estudo foi avaliar a resistência a fratura de 3 compósitos indiretos aplicados diretamente sobre abutments de Ti-6Al-4V, implanto suportados. Quarenta e oito abutments coroas integrados foram alocados aleatoriamente em 3 grupos. Os abutments foram submetidos à abrasão (sandblasting) e em seguida foram deixados em recipiente contendo etanol, por 5min no ultra-som. Depois de secos em condições ambientais, um molde personalizado foi utilizado para confecção de coroas idênticas (n=16 por grupo) deTescera (Bisco, Schaumburg,USA), Ceramage (Shofu, Kyoto ,Japan), e Diamond Crown (DRM Research Laboratories,Braford, CT,USA). As coroas foram fabricadas de acordo com as instruções do fabricante. As coroas foram carregadas mecanicamente até a fratura através de um identador posicionado na ponta de uma das cúspides com uma velocidade avaliada em 1mm/min. Em seguida a análise das fraturas foi realizada através de estereomicroscopia e microscópico eletrônico de varredura. ANOVA, com nível de significância 95% e Tukey`s post-hoc para comparações múltiplas foram utilizados para análise estatística. Os resultados de resistência à fratura com este tipo de carga (single-load) foram: Tescera (1130 ± 105Na), Ceramage (1099 ± 105Na), e Diamond Crown(1155 ± 105Na) (p> 0,85). A análise pela estereomicroscopia mostrou dois modos distintos de fratura das cúspides, com ou sem exposição do abutment. Fraturas sem exposição do abutment ocorreram em aproximadamente 80% das amostras de Tescera, 60% das amostras de Ceramage e 40% das amostras de Diamond. Análise das fraturas através de microscópio eletrônico de varredura (MEV) mostrou múltiplas propagações das trincas em direção a região cervical da coroa, abaixo da região de deformação plástica onde o identador contactava. Uma redução na quantidade de vazios (bolhas) foi observada na microestrutura do Tescera quando comparado com os outros materiais compósitos. Todos os compósitos apresentaram alta resistência à fratura com os valores excedendo a função oclusal normal. The purpose of this study was to test the strength to failure of three indirect composite materials directly applied onto Ti-6Al-4V implant abutments. 48 locking taper abutments were randomly allocated to three groups and were cleaned in ethanol in an ultrasonic bath for 5 minutes. After drying under ambient conditions, the abutments were grit-blasted and a custom 4-cusp molar crown mold was utilized to produce identical crowns (n=16 per group) of Tescera (Bisco, Schaumburg, USA), Ceramage (Shofu, Kyoto, Japan), and Diamond Crown (DRM Research Laboratories, Bran ford, CT,USA). The crowns were produced according to the manufacturer's instructions. The crowns were loaded to failure by an indenter placed at one of the cusp tips at a 1mm/min rate. Subsequently, fracture analysis was performed by means of stereomicroscopy and scanning electron microscopy. One-way ANOVA at 95% significance level and Tukey's post-hoc multiple comparisons were utilized for statistical analysis. The single load to failure results were: Tescera (1130 ± 105Na), Ceramage (1099 ± 105Na), and Diamond Crown (1155 ± 105Na) (p > 0.85). Stereomicroscopy analysis showed two distinct failure modes, where the loaded cusp failed either with or without abutment exposure. Fractures without abutment exposure comprised ~80% for Tescera, ~60% for Ceramage, and ~40% for Diamond crown samples. SEM analysis of the fractures showed multiple crack propagation towards the cervical region of the crown below a region of plastic deformation at the indenter contact region. A reduced amount of micro structural voids were observed for Tescera compared to the other composite materials. All composite materials presented high strength to failure values which exceeded normal occlusion function.
59

Influência da técnica de preparo na resistência à fratura de incisivos centrais bovinos restaurados com compósito

Brandeburgo, Gustavo Zanatta January 2007 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-graduação em Odontologia / Made available in DSpace on 2012-10-23T09:32:52Z (GMT). No. of bitstreams: 1 241835.pdf: 2746203 bytes, checksum: d4673068556e9e354d8c822da8916580 (MD5) / Este estudo teve como objetivo avaliar a influência da configuração cavosuperficial, com bisel e sem preparo, na resistência à fratura de restaurações diretas de resina composta em dentes anteriores fraturados. Foram selecionados 20 dentes bovinos hígidos e divididos em 2 grupos (n = 10). Os espécimes foram incluídos em cilindros de PVC com resina acrílica autopolimerizável. Todos os dentes foram submetidos a uma fratura simulada, transversal de mesial para distal, 4 mm a partir do bordo incisal, através de um disco diamantado em baixa rotação. Os espécimes foram então divididos nos dois grupos de teste: Grupo 1: os dentes receberam um bisel em 45º, restrito ao esmalte, e foram restaurados com resina composta; Grupo 2: os dentes não receberam qualquer tipo de preparo, e foram restaurados com resina composta. Os espécimes foram então submetidos ao teste de resistência à fratura, através de um dispositivo especial a um ângulo de 45º, e velocidade de cruzeta de 0,5mm/min. Os resultados mostraram uma maior resistência a fratura dos espécimes restaurados com preparo do ângulo cavosuperficial em 45º.
60

Influência da manipulação digital com luvas na resistência à compressão e tenacidade à fratura de resinas compostas

Fortkamp, Saulo January 2007 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-graduação em Odontologia / Made available in DSpace on 2012-10-23T14:34:34Z (GMT). No. of bitstreams: 1 245223.pdf: 1324560 bytes, checksum: 95cd880c248fb05c47410f009b66c8a6 (MD5) / O objetivo deste estudo foi avaliar a influência da manipulação digital com luvas na resistência à compressão e tenacidade à fratura de duas resinas compostas micro-híbridas fotopolimerizáveis, Filtek Z250 e Tetric Ceram (TC). Foram confeccionados 4 grupos experimentais (n=10) para cada teste e resina utilizada, totalizando 160 espécimes distribuídos aleatoriamente em 16 grupos de acordo com o tipo de manipulação, da seguinte forma: Grupos do teste de compressão- (1A-Z250 e 5A-TC) - espécimes manipulados com luvas contaminadas (LC); (2A-Z250 e 6A-TC) - espécimes manipulados com luvas limpas (LL); (3A-Z250 e 7A-TC) - espécimes manipulados com luvas contaminadas limpas com álcool 70% (LCLA); (4A-Z250 e 8A-TC) - espécimes manipulados com espátula (E), sem o contato com as luvas. Grupos do teste de tenacidade- (1B-Z250 e 5B-TC) - espécimes manipulados com LC; (2B- Z250 e 6B-TC) - espécimes manipulados com LL; (3B-Z250 e 7B-TC) - espécimes manipulados com LCLA; (4B-Z250 e 8B-TC) - espécimes manipulados com E. Após os testes de resistência à compressão e tenacidade à fratura, os valores foram analisados estatisticamente com ANOVA (a = 0,05) de um critério e teste de Tukey HSD. Os resultados demonstraram que houve diferença estatisticamente significante entre os grupos e que a forma de manipulação da resina teve influência nos valores de resistência à compressão e de tenacidade à fratura, tanto para a resina Z250 quanto para a resina TC. As menores médias foram encontradas nos grupos com luva contaminada. No teste de compressão da resina Z250 não houve diferença entre utilizar luva contaminada e luva limpa com álcool. O grupo de luva limpa apresentou diferença em relação ao grupo de luva contaminada. No teste de compressão da resina TC houve diferença estatística entre utilizar luva contaminada e luva limpa com álcool. O grupo de luva limpa apresentou diferença em relação ao grupo de luva contaminada, mas não apresentou diferença em relação aos grupos de luva limpa com álcool e espátula. No ensaio de tenacidade da resina Z250 o grupo de luva limpa apresentou diferença em relação ao demais grupos. No ensaio de tenacidade da resina TC o grupo de luva limpa apresentou diferença estatística em relação aos grupos de luva contaminada e espátula. Dentro das limitações deste estudo, podemos concluir que a manipulação digital de resinas compostas interfere em suas propriedades, portanto, deve ser evitada. A manipulação com espátula é o método mais recomendado.

Page generated in 0.0562 seconds