• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 186
  • 12
  • 11
  • 2
  • 2
  • 1
  • Tagged with
  • 214
  • 113
  • 38
  • 33
  • 32
  • 30
  • 28
  • 23
  • 20
  • 19
  • 18
  • 18
  • 18
  • 18
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Efic?cia do treinamento de for?a sobre par?metros cardiovasculares e antropom?tricos em adultos sedent?rios

Cabral, Carlos Ernani de Araujo Tinoco 16 March 2012 (has links)
Made available in DSpace on 2014-12-17T14:13:57Z (GMT). No. of bitstreams: 1 CarlosEATC_DISSERT.pdf: 535957 bytes, checksum: 4a4cb0797470f9dc7e83436d9bfc8330 (MD5) Previous issue date: 2012-03-16 / This study aimed to determine the influence of strength training (ST), in three weekly sessions over ten weeks, on cardiovascular parameters and anthropometric measurements. It is a before and after intervention trial, with a sample composed of 30 individuals. Participants were adults aged between 18 and 40 years, from both sexes and sedentary for at least three months previously. Tests were computed ergospirometry, CRP, PWV and body composition (dependent variables) before and after the experiment. Independent variables, age and sex, were considered in order to determine their influence on the dependent variablesevaluatedend. By comparing the initial cardiovascular parameters with those obtained after intervention in patients undergoing the ST proposed (a Student s t-test was conducted within each group for samples matched to parameters with normal distribution, while the Wilcoxin was applied for those without), there was no significant difference in PWV(p =0469) or PCR(p =0.247), but there was an increase in anaerobic threshold(AT) (p=0.004) and Maximal Oxygen Uptake(VO2max) (p =0.052). In regard to anthropometric measures, individuals significantly reduced their body fat percentage (p<0.001) and fat mass (p<0,001), as well as increasing lean mass (p<0.001). However, no changes were recorded in the waist-to-hip ratio (WHR) (p= 0.777), body mass (p=0.226) or body mass index (BMI) (p =0.212). Findings of this study lead us to believe that the proposed ST, and did not increase the VOP or PCR improves cardiorespiratory capacity and body composition. Devotees of this training can therefore safely enjoy all its benefits without risk to the cardiovascular system / O objetivo desse estudo foi verificar a influ?ncia do TF, com frequ?ncia de tr?s sess?es semanais e dura??o de dez semanas, sobre par?metros cardiovasculares e antropom?tricos. Trata-se de um estudo de interven??o do tipo antes-depois, cuja amostra foi composta por 30 indiv?duos. Os mesmos eram adultos com idade compreendida entre 18 e 40 anos, de ambos os sexos e sedent?rios h? pelo menos tr?s meses. Foram realizados os testes da ergoespirometria computadorizada, PCR, VOP e composi??o corporal (vari?veis dependentes), antes e logo ap?s o experimento. As vari?veis independentes, idade e sexo, foram aferidas no sentido de verificar seus efeitos sobre as vari?veis dependentes avaliadas. Ao comparar os par?metros cardiovasculares iniciais com os obtidos ap?s a interven??o nos indiv?duos submetidos ao TF proposto(atrav?s dos testes t de Student para amostras emparelhadas para os par?metros que tiveram distribui??o normal e para os que n?o a possu?ram, o Wilcoxon), n?o houve diferen?a significativa nem na VOP (p =0.469) nem na PCR (p=0,247), por?m houve aumento no Limiar Anaer?bio (LA) (p=0,004) e no consumo m?ximo de oxig?nio (VO2m?x) (p=0,052). Em rela??o ?s medidas antropom?tricas, os indiv?duos diminu?ram significativamente o percentual de gordura (p<0,001) e a massa de gordura (p<0,001), aumentaram a massa livre de gordura (p<0,001), por?m n?o alteraram a rela??o cintura-quadril (RCQ) (p= 0,777), massa corporal (p=0,226) nem o ?ndice de massa corporal (IMC) (p =0,212). Os achados do presente estudo nos levam a crer que o TF proposto, al?m de n?o aumentar a VOP nem a PCR, melhora a capacidade cardiorrespirat?ria e a composi??o corporal. Portanto, os adeptos de tal treinamento podem usufruir, com seguran?a, de todos os seus benef?cios sem risco ao sistema cardiovascular
192

Avaliação da reatividade microvascular e da rigidez arterial em pacientes com diabetes tipo 1 / Microvascular reactivity and atrial stiffness assessment in tipe 1 diabetes

Alessandra Saldanha Matheus Fernandes da Costa 03 March 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A disfunção endotelial tem sido sugerida como evento precoce na patogênese das complicações vasculares do DM1. O presente estudo objetivou avaliar a função endotelial na microcirculação e rigidez arterial no diabetes tipo 1 comparando com controles não diabéticos e correlacionando com variáveis clínicas, demográficas e laboratoriais. Foram avaliados 57 pacientes com diabetes tipo 1 com idade de 32,5 (13-61) anos e duração de doença de 15 (1-48) anos e 53 controles através de fluxometria cutânea por laser-Doppler após iontoforese de Acetilcolina(ACh) (resposta endotélio dependente), hiperemia reativa pós oclusiva(HRPO) e a capacidade máxima de vasodilatação após hiperemia térmica. Já a resposta endotélio independente foi avaliada após iontoforese de Nitroprussiato de sódio (NPS). A rigidez arterial foi mensurada através da análise da onda de pulso digital com os índices de rigidez arterial e de reflexão. Os pacientes diabéticos foram submetidos à avaliação clínica e laboratorial (histórico de tabagismo, dose diária de insulina, duração do diabetes, uso de drogas que alteram a função endotelial como anti-hipertensivos e estatinas, níveis pressóricos, índice de massa corporal, excreção urinária de albumina, perfil lipídico, controle glicêmico e níveis de proteína C-reativa). O fluxo microvascular médio em repouso não foi diferente entre pacientes e controles , assim como a complacência arterial mensurada através do índice de rigidez arterial e do índice de reflexão. A resposta vascular a vasodilatação mediada pela ACh encontrou-se significantemente reduzida nos pacientes (p=0,002). No entanto, apesar da diferença verificada na área abaixo da curva de NPS em relação ao controle, a análise por medidas repetidas não apontou diferença entre os grupos em relação às doses entre os grupos (p=0,15). A vasodilatação cutânea máxima induzida pela hiperemia térmica foi maior entre os controles em comparação com os diabéticos &#61677;93,6(24,5-379-,9) e 56,6(31,5-204,5), respectivamente p=0,04&#61693;. Por outro lado, durante a HRPO, o aumento máximo no fluxo e a área abaixo da resposta hiperêmica não divergiram entre pacientes e controles, embora o tempo para alcançar o fluxo máximo tenha sido maior nos diabéticos do que nos controles(p=0,02). As principais variáveis correlacionadas com a microcirculação foram o ácido úrico, a hemoglobina glicada, a idade e a proteína C reativa, e com a rigidez arterial, foram a duração do Diabetes, a Pressão arterial diastólica e o HDL. Apesar da correlação entre o uso de drogas com propriedades hemorreológicas e a rigidez arterial, a exclusão dos pacientes usuários daqueles medicamentos não alterou os resultados obtidos. Concluímos que, na população de diabéticos tipo 1 estudada, a resposta vascular endotélio dependente, e a capacidade máxima de vasodilatação estão significativamente reduzidas. Não houve diferença entre diabéticos e controles quanto à rigidez arterial. Ademais, a vasodilatação microcirculatória mediada pela Acetilcolina pode ser correlacionada com a rigidez arterial em diabéticos. Estudos posteriores devem ser realizados no intuito de avaliar a influência exercida pelas drogas que alteram a função endotelial sobre a reatividade micro e macrovascular. / Endothelial dysfunction in patients with type 1 diabetes appears to be an early event in the genesis of vascular complications. The purpose of the present study is to assess endothelial function in the microcirculation and arterial stiffness, by comparing with non-diabetic controls, and correlating with clinical, demographic and laboratorial parameters. We evaluated 57 patients with type 1 diabetes aged 32.5 (13-61) years and with a disease duration of 15 (1-48)years, and 53 controls using laser Doppler flowmetry during low-current iontophoresis of acetylcholine (ACh) (endothelium dependent response), post occlusive reactive hyperemia(PORH) and maximum vasodilator function during thermal hyperemia. Endothelium-independent response was measured after iontophoresis of sodium nitroprusside (SNP).The peripheral pressure waveform was analyzed to assess the arterial stiffness. Diabetic patients underwent clinical and laboratory evaluation (smoking, disease duration, daily insulin dose, use of medications that could improve endothelial function such as antihypertensive drugs and statins, blood pressure, body mass index, urinary albumin excretion, lipid profile, glycemic control and C-reactive protein levels-CRP). Mean resting microvascular flux did not differ between control subjects and patients with type 1 diabetes, as well as arterial stiffness assessed through stiffness index and reflection index. Microvascular response to ACh was significantly reduced in patients (p=0,002). However, despite the reduction ofAUC NPS, the analysis with repeated measures disclosed no difference between the groups in relation to the doses (p=0,15). Maximal skin microvascular vasodilation induced by thermal hyperemia was found to be higher in the control group than among patients (&#61677;93,6(24,5-379-,9) e 56,6(31,5-204,5), respectively p=0,04). On the other hand, during PORH, maximal increase in flux and area under the curve of the hyperemic response did not differ between patients and controls, although the time frame to reach maximum flux and the time to half recovery after hyperemia was longer in patients than in controls (P=0.02) . Uric acid, hba1c, age and CRP were the most important contributing factors to the variation of microvascular reactivity, while disease duration, the diastolic arterial pressure and HDL cholesterol were independently associated to arterial stiffness. Despite the correlation between drugs with hemorheologycal properties and arterial stiffness, the exclusion of patients who were taking such substances did not affect the results. We conclude that in the studied population of type 1 diabetic patients, the endothelium-dependent vascular responses and maximal vasodilator capacity are significantly reduced. In what concerns arterial stiffness, our study disclosed no difference between diabetics and controls. Moreover, Acetylcholine response can be correlated to arterial stiffness in diabetics, and further studies aiming at the evaluation of the micro and macrovascular reactivity should be performed with consumers of drugs which may be likely to affect the endothelial function.
193

Análise da influência da rigidez das ligações viga-pilar no comportamento estrutural de edifícios de múltiplos pavimentos em concreto armado / Analysis of the influence of the stiffness of beam-column connections on the structural behavior of reinforced concrete buildings with multiple floors

Santos, Júlia Borges dos 25 April 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Conventional structural analysis of buildings in reinforced concrete is performed considering beam-column connections as rigid. However, experimental results prove the existence of relative rotations in beam-column connections of reinforced concrete structures, showing the partial transfer of bending moment. In this study the influence of the stiffness of beam-column connections on the structural behavior of multi-storey buildings in reinforced concrete was investigated. On a first stage, the value of the rotation restriction of connections was varied, observing the impact on horizontal displaceability of the structure, on the &#947;z coefficient, on the negative and positive moments of the beams and on the longitudinal reinforcement of the pillars. This analysis was performed for buildings with 05, 10, 15 and 19 floors. The results show that the reduction of the rotation restriction of connections increases the values of the horizontal displacements, of the &#947;z coefficient, of the positive moments and of the reinforcement of the pillars. The increases that occur on the values of the analyzed parameters become larger as the number of floors of buildings increases. On a second stage, the same building was calculated with rigid connections and deformable connections. In order to determine the factor &#945;R of deformable connections, two analytical models available in literature were used, and a comparison between the results obtained by each analytical model was also performed. Based on the results, it is concluded that neglecting the influence of the stiffness of the beam-column connections on the analysis of monolithic reinforced concrete structures may result in different solutions compared to the real behavior of the structure. The stiffness values obtained with the analytical models that were used differ considerably from the condition of rigid connections, suggesting an adjustment on the standard consideration of rigid connections adopted by the computer programs of structural calculation. / A análise estrutural convencional de edificações em concreto armado é realizada considerando as ligações viga-pilar como rígidas. Entretanto, resultados experimentais comprovam a existência de rotações relativas nas ligações viga-pilar de estruturas de concreto armado, evidenciando a transmissão parcial de momento fletor. Neste trabalho foi investigada a influência da rigidez das ligações viga-pilar no comportamento estrutural de edificações de múltiplos pavimentos em concreto armado. Em uma primeira etapa, variou-se o valor de restrição à rotação das ligações observando os impactos na deslocabilidade horizontal da estrutura, no coeficiente &#947;z, nos momentos negativos e positivos das vigas e nas armaduras longitudinais dos pilares. Esta análise foi realizada para edificações com 05, 10, 15 e 19 pavimentos. Observou-se por meio dos resultados que a redução da rigidez à rotação das ligações provoca aumento nos valores dos deslocamentos horizontais, do coeficiente &#947;z, dos momentos positivos das vigas e das armaduras dos pilares. Os acréscimos ocorridos nos valores dos parâmetros analisados são maiores à medida em que se aumentam o número de pavimentos das edificações. Em uma segunda etapa, calculou-se uma mesma edificação com ligações rígidas e com ligações deformáveis. Para determinação da restrição à rotação das ligações deformáveis, utilizaram-se dois modelos analíticos disponíveis na literatura, realizando-se, também, uma comparação entre os resultados obtidos pelos modelos. Com base nos resultados, conclui-se que negligenciar a influência da rigidez das ligações viga-pilar na análise de estruturas monolíticas em concreto armado pode gerar soluções muito diferentes do comportamento real da estrutura na prática. Os valores de rigidez obtidos pelos modelos analíticos utilizados divergem consideravelmente da condição de ligações rígidas, sugerindose a adequação na consideração padrão de ligações rígidas adotada pelos programas computacionais de cálculo estrutural. / Mestre em Engenharia Civil
194

Contribuição ao estudo do comportamento dinâmico e aeroelástico de laminados compósitos de rigidez variável

Guimarães, Thiago Augusto Machado 20 December 2016 (has links)
O trabalho de pesquisa realizado trata do comportamento dinâmico e aeroelástico em compósitos laminados de rigidez variável (LCRV). Em virtude dos avanços das técnicas de manufatura de laminados, este tema tem ganhado notoriedade internacional e sua importância se justifica pelo crescente número de trabalhos na área. Neste contexto, foram analisados dois tipos distintos de LCRV: o primeiro diz respeito a laminados fabricados com espaçamento variável entre as fibras paralelas; e o segundo trata de laminados fabricados com deposição das fibras por caminhos curvilíneos, termo em inglês tow steering. Com objetivo de explorar as características dos LCRV, foi desenvolvido um modelo aeroelástico baseado no método dos modos admitidos (Rayleigh-Ritz), utilizando as hipóteses da teoria clássica de laminação (TCL), e foi utilizado o modelo aerodinâmico baseado na teoria das faixas quase estacionária para as análises em escoamentos subsônicos, e na teoria dos pistões, para escoamentos supersônicos nas análises de flutter de painel. Assim, foi investigada a influência do efeito de diferentes funções de distribuição do volume de fibras no comportamento aeroelástico e nas três primeiras frequências naturais, constatando-se uma significativa influência nos resultados, justificando um tratamento adequado para modelagem microestrutural dos laminados com espaçamento variável. Por outro lado, com objetivo de analisar o efeito de incertezas no processo de fabricação nos LCRV fabricados com a tecnologia de tow steering, foi desenvolvida uma estratégia de identificação de incertezas e sua propagação no modelo numérico, além da otimização para obtenção de um projeto robusto. Constatou-se que a melhor configuração obtida pela otimização determinística apresentou grande dispersão quando perturbado o ângulo de definição da trajetória das fibras, diferentemente da configuração selecionada de maneira robusta, que apresentou resultados menos sensíveis a perturbações nos ângulos de deposição das fibras. Foi investigada também a viabilidade da utilização de LCRV do ponto de vista dinâmico, visando aumentar a frequência natural fundamental, e com aplicação em flutter de painel. Em ambas as aplicações foi otimizada a trajetória da deposição das fibras, com base nos polinômios interpoladores de Lagrange, sendo encontrados ganhos razoáveis quando comparados com os laminados de material composto tradicionais de rigidez constante (LCRC). Adicionalmente, foi verificado que os resultados obtidos para o LCRC e o LCRV analisados experimentalmente corroboraram os resultados obtidos numericamente no que diz respeito às frequências naturais e aos modos de vibrar. / The developed research work is related to the dynamic and aeroelastic behaviors of variable stiffness composite laminate plates (VSCL). Due to the advances in the manufacturing techniques, this research theme has been gaining international relevance and its importance is justified by the increasing number of research works in this area. In this context, two different types of VSCL are analyzed: the first regards variable fiber spacing laminates, and the second is manufactured using curvilinear paths (tow steering). In order to explore the VSCL characteristics, it was developed an aeroelastic model based on the assumed modes approach (Rayleigh-Ritz), using the hypotheses of “classical lamination theory” (CLT). Moreover, it was used the aerodynamic model based on the quasi-steady strip theory in the subsonic analyses, and the piston theory, for supersonic flows used in the evaluation of panel flutter. It was investigated the influence of different fiber volume distribution on the aeroelastic behavior and on the first three natural frequencies; it has been found that those influences are significant, which justifies the adequate treatment for the micro -structural model of VSCL. Also, to cope with uncertainties during manufacturing of steered composite laminates, it was developed a strategy for identification of those uncertainties and their propagation through the numerical model; also, an optimization procedure was proposed to achieve robust designs. It was noticed that the response of the optimal configuration obtained from deterministic optimization presented a large dispersion when the tow steering angles were perturbed, in contrast with the selected configuration obtained from robust optimization, in which the results were much less sensible to perturbations in the tow steering angles. Also, it was investigated the viability to use LCRV from the dynamic standpoint, aiming at increasing the fundamental frequency, and with application in flutter panel. For both applications, the fiber placement trajectory was optimized based on Lagrange polynomials. Reasonable gains were found with respect to constant stiffness composite laminates (CSCL). Additionally, it was verified that the obtained experimental results for VSCL and CSCL corroborate the counterparts obtained from numerical simulations regarding natural frequencies and mode shapes. / Tese (Doutorado)
195

Investigação experimental de vibrações induzidas por escoamento em cilindros flexíveis com rigidez ortotrópica. / Flow-induced vibration experimental investigation in flexible cylinders with orthotropic bending stiffness.

Wagner Antonio Defensor Filho 23 March 2018 (has links)
Em experimentos com um cilindro flexível com rigidez a flexão ortotrópica, proporcionando razão entre frequências naturais longitudinal e transversal muito próximas a quatro (fx1fy1/=4,08), Fujarra et al (2001) [17] revelaram um ramo de resposta em VIV em alta velocidade. Tal ramo de respostas estável, excitado por perturbações a montante, era caracterizado por amplitudes transversais ao escoamento com ordem de 1 diâmetro e componentes de alta frequência no espectro de energia, estendendo-se por faixa de velocidade reduzida 12 < U* < 20 e esvaindo-se a partir da emergência de oscilações no segundo modo de vibração. Almejando aprofundar as investigações acerca deste intrigante achado experimental, uma nova campanha investigativa foi planejada e executada. Quatro cilindros flexíveis com distintas razões de rigidez ortotrópica foram construídos em resina polimérica, com enrijecedores internos de seções retangulares feitos de alumínio, resultando um conjunto com frequências naturais, correspondentes a modos longitudinais e transversais, com razões relativas: 4:1, 3:1, 2:1 e 1:1. Os cilindros foram verticalmente fixados a uma célula de carga 3D. Uma série de ensaios foi conduzida, sob velocidade de escoamento crescente e decrescente. As vibrações dos cilindros flexíveis foram capturadas através de um sistema óptico subaquático, posicionado a jusante, que rastreava a posição de alvos constituídos por fitas refletivas afixadas ao longo do comprimento do cilindro. Clássicas técnicas de análise espectral, decomposição modal no domínio do tempo e a Transformada de Hilbert-Huang foram utilizadas de modo encadeado e recursivo com o fim de determinar as respostas de vibração, em amplitude e frequências dominantes, em função da velocidade reduzida. O ramo de resposta em altas velocidades reduzidas foi recuperado nos experimentos com os quatro cilindros. Análise comparativa sistemática permitiu concluir que o ramo de resposta em tela se deve ao lock-in de modos longitudinais, que são excitados em velocidades reduzidas tão mais altas quanto maior for a razão de frequências considerada. Empregando-se, então, os deslocamentos e velocidades modais medidos em formulação de Mineto (2013) [23], foi realizada estimativa de potência elétrica a ser extraída pelo emprego de finos filmes de material piezelétrico depositados sobre as lâminas enrijecedoras internas aos cilindros. / A previous work by Fujarra et al. (2001) revealed a \"high speed mode branch\" in cantilevered flexible cylinders subjected to VIV. That work studied a flexible cylinder with orthotropic bending stiffness in a recirculating water channel, by setting the ratio between the first natural frequencies, in the in-line and cross-wise directions to the flow, very close to four (fx1fy1/=4,08). Such a new stable response branch, triggered by upstream hydrodynamic perturbations, was characterized by amplitudes, perpendicular to the flow, of order of one diameter and by high frequencies components in the energy spectrum. The branch extends from reduced velocity circa 12 up to 20, being extinguished by the onset of the second vibration mode lock-in. Aiming at investigating further this intriguing experimental finding, a new campaign has been planned and performed. Four flexible cylinders with distinct orthotropic bending ratios were built, by molding thin aluminum stiffeners, of rectangular cross section, inside the cylinders made of a flexible resin. The respective natural frequencies ratio, between in-line and cross-wise bending modes, was set to 4:1, 3:1, 2:1 and 1:1. The flexible cylinders were vertically clamped to a 3D load cell. A series of experimental runs were carried out, under ascending and descending flow speeds. The flexible cylinder vibration was captured trough an underwater optical system, placed downstream, by tracking 3D Cartesian coordinates of reflective strips placed all along the span, at equi-spaced cross sections. Besides standard spectral analysis techniques, modal decomposition in time domain and the Hilbert-Huang Transform have been recursively used together to determine amplitude and dominant response frequencies. The \"high speed mode branch\" revealed for all four cylinders tested. Systematic comparative analysis allowed us to conclude that such a response branch is caused by the lock-in of longitudinal modes, excited at reduced velocities ranges that increase with the frequency ratio considered. Finally, using measured modal responses in Mineto (2013) [23] formulation, the electric power that would be extracted by the use of thin piezoelectric layers deposited over the internal stiffeners blades was estimated.
196

Estudo do polietileno de alta densidade reciclado para uso em elementos estruturais / Recycled high density polyethylene characterization for use in structural members

Lívia Matheus Candian 19 September 2007 (has links)
O alto consumo de energia para a produção de metais e de cimento, a pressão em relação à utilização de madeira tropical e a abundância de material plástico vêm contribuindo para o desenvolvimento de pesquisas e a aplicação dos termoplásticos na construção civil, em elementos estruturais que, em sua grande maioria, são constituídos de madeira, de aço e de concreto. O progresso dos materiais poliméricos pode ser comprovado pelos diversos produtos que estão sendo projetados, principalmente na Europa e nos Estados Unidos, como passarelas, dormentes, marinas, etc. Foi escolhido o polietileno de alta densidade (PEAD) reciclado, por ser um dos materiais poliméricos rígidos mais disponíveis para reciclagem. Nesse contexto, o objetivo deste trabalho foi a caracterização do PEAD reciclado. Foi determinada a composição do material polimérico (PEAD) reciclado obtido no mercado, por meio dos ensaios termoanalíticos: calorimetria exploratória diferencial e análise termogravimétrica. Os resultados mostraram que o material fornecido pela empresa de reciclagem é isento dos contaminantes comumente encontrados nos materiais reciclados e apresenta um grau de pureza bastante significativo. A determinação das propriedades mecânicas, por meio dos ensaios de tração, de compressão, de flexão e de impacto Izod, finaliza o estudo do material analisado. Nesses ensaios, a resistência obtida foi próxima dos valores encontrados na literatura, para o PEAD virgem, e pouco inferior à do concreto e à da madeira. Entretanto, a rigidez do PEAD reciclado foi bem menor que a dos materiais de construção tradicionais, sendo essa sua maior deficiência. Concluiu-se que o PEAD reciclado pode ser aplicado em elementos estruturais, desde que sejam estudadas possíveis formas de controlar sua deformabilidade, como a incorporação de nervuras, a utilização de blendas poliméricas e adição de cargas minerais e de fibras de elevado módulo de elasticidade e resistência. / The use of thermoplastics in civil engineering has been increasing considerably in the last decades. The latter is due to large amount of plastic material and high cost on a production of metals and cement for reinforced concrete, besides the lack of wood. This could be proved by the development of new thermoplastics products, especially in Europe and United States, like bridges, railway sleepers, posts, etc. Recycled high density polyethylene (HDPE) was chosen due to the fact that it is one of the most rigid recycled polymers available on the recycling industry. In this study, recycled polymer has been characterized in order to determinate the recycled material composition available in the market. The characterization of recycled HDPE samples was made by thermo gravimetric analysis and differential scanning calorimetry. Consequently, mechanical properties were determinated by tensile test, compression test, flexural test and impact Izod. The results of thermal analysis showed that the recycled material is exempt from possible contaminants and has a significant pureness degree. Under tension, compression, bending and impact conditions, the strength was around the pure polymer and little smaller of the concrete and wood. In contrast, the stiffness was much lower in comparison to traditional materials, their worst characteristic. These problems could be overcome through the study of polymeric blends, adding high modulus and strength fibers and charges and adding ribs. Then the recycled polymer could be applied as a structural element.
197

Efeitos da atividade física aeróbica sobre a pressão arterial sistêmica e rigidez arterial em pacientes submetidos a transplante cardíaco / Effects of aerobic physical activity on blood pressure and arterial stiffness in patients undergoing cardiac transplantation

Lucas Nóbilo Pascoalino 19 October 2012 (has links)
O transplante cardíaco permanece sendo o procedimento de escolha para a insuficiência cardíaca refratária, apresentando resultados favoráveis em termos da sintomatologia, qualidade de vida e sobrevida desses pacientes. A hipertensão arterial sistêmica aparece como a comorbidade de maior incidência neste grupo de pacientes, chegando a 95% após cinco anos. O efeito do exercício físico sobre a dinâmica do comportamento tensional na monitorização da pressão arterial ambulatorial durante 24 horas (MAPA-24h) e da rigidez arterial não tem sido estudado neste grupo de pacientes. Nós avaliamos os efeitos da atividade física aeróbia sobre a dinâmica do comportamento tensional na MAPA-24h, rigidez arterial e as variáveis cardiovasculares em indivíduos após um ano de transplante cardíaco. Trinta e nove pacientes de ambos os sexos, randomizados para grupo treino (GT) (n = 29; 45 ± 13 anos) ou grupo controle (GC) (n = 9; 51 ± 11 anos) realizaram, antes e após o período de 12 semanas de seguimento, exames de MAPA-24h, velocidade de onda de pulso carótido-femoral (VOP) e teste de esforço cardiopulmonar, com coletas de amostras sangüíneas para dosagem de norepinefrina (Nor) (repouso e pico). Treinamento físico aeróbio foi realizado três vezes por semana, sendo duas supervisionadas e uma não supervisionada, durante 40 minutos inicialmente com a frequência cardíaca monitorada em 80% do ponto de compensação respiratória. O GT apresentou redução significativa da pressão arterial sistólica nos períodos da média das 24 horas (de 120 ± 11 para 116 ± 14mmHg, p<0,05) e vigília (de 123 ± 11 para 118 ± 13mmHg, p<0,05). A pressão arterial diastólica apresentou redução significativa para os três períodos sendo na média das 24 horas (de 81 ± 9 para 74 ± 9mmHg, p< 0,001), vigília (de 83 ± 9 para 75 ± 10mmHg, p<0,001) e noturno ( de 77 ± 10 para 71 ± 10mmHg, p<0,001). A VOP não apresentou redução significativa após o período de seguimento para ambos os grupos; GT (de 10,0 ± 1,9 para 9,7 ±1,9m/s, p = ns) e GC (de 10,3 ± 2,2 para 10,4 ± 2,8m/s, p = ns), porém os níveis da Nor tiveram aumento significativo no pico do exercício no grupo GT (de 2386 ± 1274 para 3292 ± 1410 pg/ml p<0,01) e também em relação ao grupo GC pós seguimento (3292 ± 1419 versus 2178 ± 659 pg/ml, p<0,05). O treinamento físico aeróbio reduziu a pressão arterial sistólica/diastólica em 4,7/7,5 mmHg durante a vigília e em 3,5/5,8 mmHg durante o sono após TX, além de melhorar o condicionamento cardiorrespiratório com aumento do VO2pico, FCmáx e do tempo de exercício. / Cardiac transplantation remains the procedure of choice for refractory heart failure, with favorable results in terms of symptoms, quality of life and patient survival. Hypertension appears as a higher incidence of comorbidity in this group of patients, reaching 95% after five years. However, the effect of exercise training in the behavior of 24-hour ambulatory blood pressure monitoring (ABPM) and arterial stiffness has not been studied in this group of patients. We assessment the effects of aerobic physical activity in the behavior of ABPM, arterial stiffness and cardiovascular variables in patients being heart transplanted for a year or more. Thirty-nine patients of both genders were evaluated, then randomized to either training group (TG) (n = 29, 45 ± 13 years) or control group (CG) (n = 9, 51 ± 11 years) and reevaluated after 12 weeks of follow-up. Pre and post evaluations combined examinations of ABPM, carotidfemoral pulse wave velocity (PWV) and graded exercise test, with collections of blood samples for measurement of norepinephrine (Nor) (rest and peak). Aerobic exercise was performed in the TG three times-a-week, two supervised and one unsupervised for 40 minutes initially at an intensity of 80% of heart rate achieved at the respiratory compensation point. The TG showed a significant reduction in systolic blood pressure during average of 24 hours (from 120 ± 11 to 116 ± 14mmHg, p < 0.05) and diurnal cycle (from 123 ± 11 to 118 ± 13mmHg, p<0.05). Diastolic blood pressure decreased significantly for the three periods, the average of 24 hours (from 81 ± 9 to 74 ± 9mmHg, p<0.001), diurnal cycle (from 83 ± 9 to 75 ± 10mmHg, p < 0.001) and nighttime (from 77 ± 10 to 71 ± 10mmHg, p < 0.001). The PWV showed no significant reduction after the followup period for both groups; TG ( from 10.0 ± 1.9 to 9.7 ± 1.9m/s, p = ns) and CG (from10.3 ± 2.2 to 10.4 ± 2.8m/s, p = ns) and the levels of the Nor had a significantly higher peak exercise in TG (from 2386 ± 1274 to 3292 ± 1410 pg/ml p <0.01) and also in relation to the control group after follow-up (3292 ± 1419 versus 2178 ± 659 pg / ml, p <0.05). The exercise training reduced both systolic and diastolic blood pressure in 4.7 and in 7.5 mmHg during daytime, respectively. Reduction also happened during nighttime in 3.5 and in 5.8 mmHg for these variables, respectively. Exercise training improved VO2peak, HRmax and time of exercise (cardiorespiratory fitness) after follow-up, as well.
198

A flexibilidade de RH como motivo de adoção de modelos de gestão da saúde pública alternativos ao estatuário: as experiências dos Estados da Bahia, do Paraná e de São Paulo

Fagundes, Maísa Cristina Dante 20 July 2018 (has links)
Submitted by Maísa Fagundes (maisa.fagundes@fgv.br) on 2018-08-17T18:28:19Z No. of bitstreams: 1 A flexibilidade de RH.pdf: 1769015 bytes, checksum: f21dc7c1597b2b8486977eccff9aae43 (MD5) / Approved for entry into archive by Pamela Beltran Tonsa (pamela.tonsa@fgv.br) on 2018-08-20T13:14:30Z (GMT) No. of bitstreams: 1 A flexibilidade de RH.pdf: 1769015 bytes, checksum: f21dc7c1597b2b8486977eccff9aae43 (MD5) / Approved for entry into archive by Suzane Guimarães (suzane.guimaraes@fgv.br) on 2018-08-20T16:23:42Z (GMT) No. of bitstreams: 1 A flexibilidade de RH.pdf: 1769015 bytes, checksum: f21dc7c1597b2b8486977eccff9aae43 (MD5) / Made available in DSpace on 2018-08-20T16:23:42Z (GMT). No. of bitstreams: 1 A flexibilidade de RH.pdf: 1769015 bytes, checksum: f21dc7c1597b2b8486977eccff9aae43 (MD5) Previous issue date: 2018-07-20 / A Administração Pública brasileira tem passado, desde que se tem notícia, por ciclos alternados de enrijecimento e de mitigação do rigor, no que toca às normas jurídicas que a regem. Desde a década de 1990, com a Reforma do Aparelho do Estado, que refletiu um movimento mundial de revisão do perfil de Estado adequado à realidade contemporânea, almeja-se no Brasil um abrandamento das regras jurídicas que engessam o poder decisório do administrador público. Essa rigidez normativa havia piorado com a edição da Constituição Federal de 1988. O Plano Diretor da Reforma do Aparelho do Estado (PDRAE) trouxe instrumentos de flexibilização, dentre os quais a transferência do exercício da atividade estatal não-exclusiva para entidades não-estatais, públicas ou privadas. Os anos seguintes foram de criação de entidades públicas, de estabelecimento de parcerias ou de contratação, envolvendo tanto entidades públicas não-estatais (filantrópicas) quanto privadas (sociedades empresariais). Surgiram, então, as organizações sociais, a nova vertente de serviços sociais autônomos, as parcerias público-privadas, várias fundações estatais etc. Contudo, houve grande oposição a esses novos modelos de gestão. Entidades representativas dos trabalhadores alegavam que essa “privatização” do serviço público apenas contribuía para a precarização do trabalho. Os órgãos de controle, por sua vez, endureceram interpretações, reduzindo o alcance das poucas flexibilidades criadas. Mas os governos continuaram utilizando esses modelos, principalmente na área da saúde pública, escolhida para o presente estudo. Então pode-se concluir que o motivo dessa escolha de novos modelos de gestão é a busca por flexibilidade? Em caso positivo, qual flexibilidade? Como a gestão de pessoal é um ponto sensível na área da saúde, que engloba a prestação de serviços nos quais o elemento humano é indispensável, decidiu-se analisar a escolha desses modelos segundo a flexibilidade de recursos humanos (RH). Para tanto, realizou-se uma pesquisa qualitativa sobre três Estados, que apresentam casos emblemáticos: a primeira parceria público-privada na saúde do País, na Bahia; a bem-sucedida fundação estatal do Paraná; e as organizações sociais que hoje predominam em São Paulo. Foram feitas entrevistas semiestruturadas e análises de documentos, a fim de aferir se a flexibilidade contratual é mesmo o fator decisivo na adoção de um modelo de gestão do trabalho na saúde pública alternativo ao estatutário. As amostras escolhidas foram analisadas segundo a tipologia de flexibilidade em RH criada por Francisco Longo (2007). Foi possível concluir que a flexibilidade contratual está presente nos modelos analisados, mas que o conceito mais genérico de flexibilidade, limitado ao afastamento da rigidez legal, parece ter sido o verdadeiro móvel da escolha. / The Brazilian Public Administration has been governed by alternating cycles of rigorous and non-rigorous application of legal norms. In the 1990s, with the introduction of reforms in the State apparatus in Brazil to reflect the worldwide movement, the State profile was changed to suit contemporary reality, and relaxation of legal norms that undermined the decision-making power of the public manager was sought. Legal norms had become more rigid with the adoption of the Federal Constitution of 1988. The masterplan for reforming the State apparatus (PDRAE) established flexibility mechanisms, including transfer of responsibility of non-exclusive state activity to non-state public or private entities. Subsequent years witnessed the creation of public entities and establishment of partnerships and contracts involving both non-state public entities (philanthropic) and private organizations (corporations). Next, social organizations, the new strand of autonomous social services, public-private partnerships, and several state foundations emerged. However, there was great opposition to these new management models. Representative bodies of workers claimed that “privatization” of public services only contributed to job insecurities. The controlling agencies, in turn, hardened their stance and reduced the reach of the few flexibilities provided. However, governments continued to use these models, especially in public health, the area chosen for analysis in the present study. Thus, is it possible to conclude that the quest for flexibility is the main reason for adopting new management models? If so, which flexibility? As human resources is a sensitive aspect in the health field encompassing the provision of services in a field where presence of people is fundamental, we decided to analyze the adoption of these models based on the flexibility of human resources (HR). To this end, we analyzed three emblematic cases of Brazilian states using a qualitative approach: the first national public-private partnership in the health field in Bahia; the successful state-owned foundation of Paraná; and social organizations in São Paulo. Semi-structured interviews were conducted and documents were analyzed to assess whether contractual flexibility is the decisive factor in the adoption of these labor management models in public health, as an alternative to the statutory model. The selected samples were analyzed according to the human resources flexibility framework developed by Francisco Longo (2007). It was possible to conclude that even though flexibility is seen in the models analyzed, the model was adopted only for its broader aspect of flexibility, limited to the easing of regulatory rigidity.
199

Efeito do comprimento do parafuso e da rigidez da união no limite de fadiga de uniões parafusadas / The Effect of bolt length and of joint stiffness in the fatigue limit of bolted joints

Silva, Marcio Erick Gomes da 16 August 2013 (has links)
The design of a bolted joint shall consider several factors such as material and heat treatment of the bolt (defined by the class of the bolt), stiffness of the parts being assembled (stiffness of the union), dimensions of the bolt, among others. In our study we used bolts M6x1, class 8.8, with three different lengths: 40 mm, 60 mm and 80 mm. The purpose of this study is to verify the relationship between the length of the bolt and the fatigue limit of the bolted joints, subjected to fluctuating cyclic loading of tension. The results indicated that the greater the length of the bolt, the larger the fatigue limit. An analytical study was also evaluated on the relationship between the cyclic stress amplitude and the mean stress experienced by the bolts with 40 mm of length. The results were compared with the bolt fatigue diagram of the BURGUETE and PATTERSON (1995). Correction factors were proposed for the relationship between cyclic stress amplitude. The adapted model from LEHNHOFF and WISTEHUFF (1996) for M6 bolts was the one whose results were the closest to estimated. / O projeto de uma união parafusada deve considerar diversos fatores tais como material e tratamento térmico do parafuso (definidos pela classe do parafuso), rigidez das peças que estão sendo montadas (rigidez da união), dimensões do parafuso, entre outros. Em nosso estudo utilizamos parafusos M6x1, classe 8.8, com três comprimentos distintos: 40 mm, 60 mm e 80 mm. A proposta deste estudo é verificar a relação do comprimento do parafuso com o limite de fadiga de uniões parafusadas submetidas a carregamentos cíclicos de tração. Os resultados indicaram que quanto maior o comprimento do parafuso, maior é o limite de fadiga. Foi realizado ainda um estudo analítico da relação entre a amplitude de tensão e a tensão média suportada pelos parafusos de 40 mm de comprimento. Os resultados foram comparados com o diagrama de BURGUETE e PATTERSON (1995). Foram propostos coeficientes de correção para a relação entre as amplitudes de tensão. O modelo de rigidez adaptado de LEHNHOFF e WISTEHUFF (1996) para parafusos M6 foi o que apresentou resultado mais próximo aos estimados.
200

Estudo da ligação viga-pilar em sistema estrutural de concreto considerando a variação da semi-rigidez por meio de parâmetros geométricos da ligação / Study of beam-column connection in structural concrete system considering the variation of semi-rigidity through geometric parameters of the connection

Araújo, Tássio Jorge Figueiredo de 26 July 2013 (has links)
This work presents a study to quantify the influence of geometrical and stiffness parameters on the behavior of beam-column concrete connections. Therefore, linear elastic models are designed by using three-dimensional finite elements in the commercial software Abaqus. These models serve as a reference for the optimization of geometrical and rigidity parameters of reticulated models, which are commonly used in structural projects. The results confirm some tendencies of influence by parameters already reported in the literature, such as variations in stiffness caused by eccentricity and width variations. The results indicate variations in vertical displacement of the beams up to 5%, maintaining the vertical load and varying only the eccentricity and up to 60% only by varying the widths of the elements. Furthermore, the use of punctual representations of semi-rigidity on monolithic concrete connections through rotational springs is discarded, proving necessary an improvement of the model to represent the behavior of the connection. Several models have been proposed and tested in the representation of the semi-rigid behavior of the connections, making use of rigid core, rotational springs and variations of inertia and area. / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / Este trabalho apresenta um estudo de quantificação da influência de parâmetros geométricos e de rigidez no comportamento de ligações viga-pilar de concreto. Para tanto, são concebidos modelos elásticos lineares de ligação em elementos finitos tridimensionais utilizando o programa comercial Abaqus. Esses modelos servem como referência para a otimização dos parâmetros geométricos e de rigidez de modelos reticulados, que são os comumente utilizados em projetos estruturais. Os resultados obtidos confirmam algumas tendências de influência de parâmetros já apresentados na literatura, como variações de rigidez causadas por excentricidade e variações de largura. Os resultados indicam variações de deslocamento vertical nas vigas de até 5%, mantendo-se a carga vertical e variando apenas a excentricidade, e de até 60% variando-se apenas as larguras dos elementos. Além disso, é descartada a utilização de representações pontuais da semi-rigidez em ligações monolíticas de concreto através de molas rotacionais, provando ser necessário um aprimoramento do modelo para a representação do comportamento da ligação. Diversos modelos de barra são propostos e testados na representação do comportamento semi-rígido das ligações, fazendo uso de núcleos rígidos, molas rotacionais e variações de inércia e área.

Page generated in 0.085 seconds