• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 250
  • 117
  • 51
  • 39
  • 30
  • 10
  • 6
  • 5
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 627
  • 627
  • 260
  • 177
  • 163
  • 163
  • 123
  • 115
  • 113
  • 111
  • 109
  • 108
  • 102
  • 92
  • 78
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
491

Desenvolvimento de métodos de extração e determinação de bifenilas policloradas por cromatografia gasosa e detector de captura de elétrons em óleo Ascarel, reator anaeróbio e solo / Development and validation of a method for determination of Polychlorinated Biphenyls (PCBs) of a standard solution PCB Congener MIX 1 by gas chromatography and electron capture detector in three different matrices: Askarel oil, samples from batch anaerobic reactors and soil

Adorno, Maria Angela Tallarico 23 August 2013 (has links)
Bifenilas policloradas (PCBs) são componentes de óleo ascarel, usado extensamente (no Brasil até os anos 80) como isolante em transformadores de energia devido às suas propriedades físico-químicas como estabilidade térmica e alta constante dielétrica. Apesar de ter sido proibido em todo o mundo devido à alta toxicidade dos PCBs presentes em sua composição, ainda resta grande quantidade de ascarel em circulação como resíduo \"passivo\" e resultante de contaminação em trocas dos fluidos dos transformadores, além de vazamentos. A principal forma de eliminação é por incineração, que, além de ser um processo caro, pode provocar a formação de compostos mais tóxicos, as dioxinas. Por isso é importante o monitoramento da concentração dessas substâncias, a fim de evitar maiores impactos ambientais na sua disposição, bem como em estudos de biodegradação. Esta matriz é extremamente complexa, o que torna a extração e determinação desses analitos um processo trabalhoso e difícil. Neste trabalho avaliaram-se métodos de extração e determinação de PCBs presentes na solução padrão comercial PCB Congener MIX 1, SUPELCO (PCBs 10, 28, 52, 138, 153 e 180). O desenvolvimento de métodos de extração (cromatografia em coluna, extração líquido-líquido (L-L), extração em fase sólida (SPE) e micro-extração em fase sólida - SPME) dos PCBs foi seguido da determinação, por cromatografia gasosa com detector por captura de elétrons (CG/DCE), em três matrizes diferentes: óleo ascarel, amostras provenientes de reatores anaeróbios em batelada e solo. Os métodos cuja purificação e extração diminuíram o efeito dos interferentes da matriz, como SPE - Sulfoxide, cromatografia em coluna de sílica e extração L-L com n-hexano foram validados pela avaliação dos seguintes parâmetros: linearidade e faixa de aplicação; precisão instrumental; limite de detecção, limite de quantificação e recuperação absoluta. O critério de escolha entre os métodos para extração dos PCBs do óleo que forneceram maior eficiência (cartucho SPE Sulfoxide e coluna de sílica gel, após lavagem ácida; método da adição de padrão, entre 1,0 e 4,0 mg L-1) deve considerar a disponibilidade de recursos, pois a sílica gel é mais viável economicamente do que o cartucho SPE. Os valores de R2 > 0,99 para o método de extração com sílica, mesmo tendo sido considerados apenas três pontos para a curva de calibração, atestam maior linearidade do que o método com SPE Sulfoxide (R2 entre 0,97 e 0,99). A extração L-L e determinação por CG/DCE dos PCBs (padronização interna) de amostras provenientes de reatores anaeróbios em batelada (aquosas, em matriz extremamente complexa com biomassa e espuma de poliuretano para imobilização de microrganismos) foram eficientes na faixa de concentração entre 0,05 e 0,5 mg L-1. Esse método foi adequado para monitorar PCBs em estudo de degradação anaeróbia e teste de adsorção dos PCBs em espuma; forneceu linearidade com R2 entre 0,93 e 0,96 e limites de detecção de 0,048 a 0,298 mg L-1, além de recuperação absoluta entre 14,1% e 110,7%. As condições testadas por SPME não permitiram a extração dos PCBs de óleo e de solo, principalmente devido à dessorção incompleta dos PCBs da fibra de polidimetil-siloxano, de 100 μm. / Polychlorinated biphenyls (PCBs) are components of ascarel, oil widely used as insulation (until the \'80s in Brazil) due to its physicochemical properties such as thermal stability and high dielectric constant. Despite having been banned worldwide due to the high toxicity of PCBs present in its composition, there are still lots of outstanding ascarel as \"passive\" residue and resulting contamination of fluids in transformers exchanges, plus leaks. The main form of disposal is incineration, which, besides being costly, can cause the formation of more toxic compounds, that is, dioxins. It is therefore important to monitor the concentration of these substances in order to prevent further environmental impacts in their disposal, as well as in studies of biodegradation. This is an extremely complex matrix, which makes the extraction and determination of this analytes very difficult and labor intensive. In this work we have evaluated methods of extraction and determination of the PCBs present in the standard solution Congener MIX 1, SUPELCO (PCBs 10, 28, 52, 138, 153 e 180). The extraction and cleanup developed methods which reduced the effects of interfering matrix as solid phase extraction (SPE) - Sulfoxide, column chromatography on silica and liquid-liquid (L-L) extraction with n-hexane, and solid phase microextraction (SPME) after determination of the PCBs by gas chromatography with electron capture detector (GC/ECD) were validated by assessing the following parameters: linearity and range of application; instrumental precision; detection limit; limit of quantification and absolute recovery. The criterion for choosing between the methods for extraction of PCBs from the oil with a higher efficiency (SPE cartridge Sulfoxide and silica gel column, after acid washing; using the standard addition method, between 1.0 and 4.0 mg L-1) must evaluate the availability resources, since the silica gel is more economically viable than the SPE cartridge. The R2 values > 0.99 for silica extraction method, even though it was considered only three points for the calibration curve, attested higher linearity than the method with SPE Sulfoxide (R2 between 0.97 and 0.99). The L-L extraction and determination by GC/ECD of the PCBs (internal standardization) of samples from batch anaerobic reactors (aqueous, in a very complex matrix with biomass and polyurethane foam for the immobilization of microorganisms) were efficient in the concentration range between 0.05 and 0.5 mg L-1. This method was suitable to monitor PCBs in anaerobic degradation studies and its adsorption on foam; provided R2 linearity between 0.93 and 0.96 and detection limits from 0.048 to 0.298 mg L-1, as well as absolute recovery between 14.1% and 110.7%. The conditions tested for SPME technique did not allow the extraction of the PCBs from the oil and soil, mainly due to the \"incomplete dessorption\" of PCBs from the polydimethylsiloxane fiber of 100 micron.
492

Novas abordagens para exploração de reações químicas relativamente lentas em sistemas de análises em fluxo. Aplicações a amostras de relevância agronômica e ambiental / Novel approaches for exploiting relatively slow chemical reactions in flow analysis systems. Applications to relevant agronomic and environmental samples

Vida, Ana Clara Felix 27 November 2015 (has links)
Diferentes estratégias foram projetadas e desenvolvidas para sistemas de análises em fluxo envolvendo reações químicas relativamente lentas. O aprisionamento da zona da amostra na bobina de reação permite melhorias de sensibilidade em métodos espectrofotométricos em fluxo envolvendo reações catalíticas. Uma característica inerente a esta estratégia é que, de acordo com as baixas concentrações do analito de interesse esperadas nas amostras, pode-se explorar tanto a variação do tempo quanto da temperatura de aquecimento para o desenvolvimento reacional. Esta estratégia evita a geração de bolhas de ar quando temperaturas elevadas são empregadas. O aprisionamento da zona da amostra na bobina de reação em sistema de análises por injeção em fluxo foi aplicado à reação de oxidação do reagente Tiron por peróxido de hidrogênio catalisada por Co(II) para determinação espectrofotométrica de cobalto em gramíneas. O sistema apresentou boas figuras de mérito, tais como repetibilidade [d.p.r. = 0,8% para 0,6 ?g L-1 Co(II), (n = 5)], limite de detecção [0,046 ?g L-1 Co(II)], frequência de amostragem (19 h-1) e consumo de reagente (330 ?g de Tiron por determinação). Os dados de recuperação nas amostras de gramíneas digeridas variaram entre 97% e 113%. O aquecimento explorando o aprisionamento da zona da amostra na cubeta de detecção mostrou-se promissor para implementação de reações relativamente lentas sem a geração de bolhas de ar, e não houve liberação de bolhas mesmo sob a temperatura de 95ºC. Esta estratégia foi aplicada à determinação espectrofotométrica de vanádio em águas minerais envolvendo a oxidação de p-anisidina por bromato catalisada por V(V) e ativada por Tiron. Sob temperatura de 95ºC, boas figuras de mérito foram obtidas, tais como limite de detecção (0,1 ?g L-1), repetibilidade [d.p.r. = 2,1 % para 5,0 ?g L-1 (n = 10)], frequência analítica [25 h-1] e consumo de reagente (3,0 mg de p-anisidina por determinação). Adicionalmente, foi desenvolvido um procedimento analítico em fluxo para monitoramento dos resíduos de ametrina e atrazina potencialmente lixiviáveis em solos, envolvendo também um processo relativamente lento. Um sistema de análises por injeção sequencial foi utilizado para as etapas de dessorção dos herbicidas com solução 0,01 mol L-1 CaCl2 e concentração em fase sólida em linha, seguida da eluição dessas espécies para a separação em uma coluna monolítica C18 conectada a um cromatógrafo líquido por meio de uma válvula de seis vias. Os eluatos eram injetados no cromatógrafo por meio de uma alça de amostragem de 300 ?L conectada à válvula. Boas figuras de mérito foram obtidas, tais como fatores de enriquecimento de 10,2 e 18,8 e limites de detecção de 0,016 e 0,015 mg L-1 para ametrina e atrazina, respectivamente, limite de quantificação de 0,05 mg L-1 para ambos os herbicidas e repetibilidade estimada como 6,3% e 5,1% para 0,05 mg L-1 (n = 10) para ametrina e atrazina, respecivamente. Os dados de adição e recuperação dos herbicidas nos extratos de solos em condições de equilíbrio se situaram na faixa de 85 a 99% / Different approaches to analytical flow systems involving relatively slow chemical reactions were developed. Zone trapping inside the reaction coil enables sensitivity improvements in flow-based spectrophotometric procedures relying on catalytic reactions. The reaction time and/or temperature can be increased for the determination of analytes present in the samples at low concentrations. Exploitation of the strategy avoids the liberation of air bubbles in the analytical path when high temperatures are involved. A flow injection system with zone trapping in the main reactor was developed for the spectrophotometric determination of cobalt in grass samples exploiting the oxidation of Tiron by bromate catalised by Co(II). Good figures of merit such as repeatability [r.s.d. = 0.8% for 0.6 ?g L-1 Co(II), (n = 5)], detection limit [0.046 ?g L-1 Co(II)], sampling frequency [19 h-1] and reagent consumption (330 ?g of Tiron for determination) were attained. Recovery data in grass sample digests varied within 97% e 113%. Zone trapping inside the flow-through cuvette for exploiting high temperatures was also promising for relatively slow reactions, as no liberation of air bubbles was noted even for temperatures as high as 95oC. The approach was applied to the spectrophotometric determination of vanadium in mineral water samples relying on the oxidation of p-anisidine by bromate catalised by V(V) at 95ºC. Good analytical figures of merit such as repeatability [r.s.d. = 2.1% for 5.0 µg L-1 V(V), n = 10], detection limit [0.1 µg L-1 V(V), sample frequency (25 h-1) and reagent consumption (3.0 mg of p-anisidine per determination) were attained. Additionally, an analytical procedure to monitor the potentially leachable ametryn and atrazine residues in soil samples was proposed. As leaching is relatively slow, a sequential injection system was used to perform the herbicide extractions with 0.01 mol L-1 CaCl2 and in-line solid phase extraction followed by elution towards a C18 monolithic column connected to a liquid chomatograph. To this end, the outlet of the column was connected to a 300-µL six-port valve. Regarding analytical performance, enrichment factors and detection limits were 10.2 and 18.8 and 0.016 e 0.015 mg L-1 for ametryn and atrazine, respectively, quantification limits were 0.05 mg L-1 for both herbicides and good repeatability (r.s.d. = 6.3 and 5.1 % for 0.05 mg L-1 of ametryn and atrazine, n = 10) were attained. Recovery data in the soil extracts under equilibrium conditions were within 85 and 99%
493

Estudo da síntese convergente de peptídeos em fase sólida: abordagem clássica e uso de temperatura alta / Study of the convergent solid phase peptide synthesis: classical approach and use of high temperature

Ruiz, Cesar Manuel Remuzgo 12 December 2003 (has links)
A síntese de peptídeos em fase sólida passo a passo (SPFS) tem sido aplicada com sucesso na preparação de peptídeos curtos, médios e de determinados sequências contendo mais de 30 resíduos. Entretanto, esta apresenta problemas e limitações que podem ser contornados pela síntese convergente de peptídeos em fase sólida (SCPFS) que se baseia na condensação entre fragmentos peptídicos Nα-acilados protegidos em suas cadeias laterais (doadores de acila) a fragmentos protegidos ligados a um suporte polimérico (receptores de acila). Além de desenvolver outros projetos enfocados na síntese de peptídeos ou no uso de sintéticos para o estudo de peptídeos biologicamente ativos ou proteinas, o nosso grupo de pesquisa tem se dedicado a estudar o emprego de temperaturas altas em SPFS. O objetivo final é propor protocolos ágeis alternativos aos empregados classicamente. Neste trabalho nos propusemos a investigar alguns aspectos da SCPFS e a explorar a possibilidade de agilizá-Ia a 60°C. Para tanto, empregamos como modelos a colecistocinina-33 humana (hCCK-33) não sulfatada e o análogo [Gln1]-gomesina. As seqüências destes peptídeos foram divididas em: doadores de acila (fragmentos central e N-terminal da hCCK-33 não sulfatada de 11 e de 5 resíduos, respectivamente, e N-terminal de 8 resíduos do [Gln1]-gomesina) e receptores de acila (fragmentos C-terminais da hCCK-33 não sulfatada de 17 resíduos e do [Gln1]-gomesina de 10 resíduos). As peptidil-resinas correspondentes foram sintetizadas manualmente por SPFS passo a passo e caracterizadas por análise de aminoácidos para determinação de seus graus de substituição. Suas propriedades de solvatação em diferentes sistemas de solventes foram também examinadas. Análises por RP-HPLC e LC/ESI-MS dos peptídeos brutos obtidos após clivagem das resinas e desproteção total permitiram avaliar as sínteses realizadas. Os doadores de acila foram então gerados a partir das peptidil-resinas empregando procedimentos conhecidos (catálise por DBU ou NaOH) e um proposto por nós (assistência por íons metálicos). Finalmente, os acoplamentos entre os doadores e receptores de acila foram realizados a 37 e 60°C empregando sistemas de solventes adequados à solvatação dos receptores de acila e diferentes reagentes acopladores. As peptidil-resinas alongadas foram analisadas em seu conteúdo de aminoácidos e submetidas à clivagem e desproteção total para liberação dos peptídeos brutos correspondentes. Estes foram submetidos à análise comparativa usando RP-HPLC e LC/ESI-MS. Os resultados obtidos neste primeiro trabalho que emprega alta temperatura na SCPFS demonstraram que: 1) o conhecimento do grau de solvatação das peptidil-resinas auxilia na escolha do sistema de solventes a ser empregado na geração dos doadores de acila (desligamento dos peptídeos protegidos correspondentes) e nos seus acoplamentos aos receptores de acila; 2) a geração de doadores de acila a partir de peptidil-KOR não é trivial como sugere a literatura (o fragmerto 6-19 da hCCK-33 na forma protegida não foi obtido) e deve ser melhor estudada. O tamanho e a seqüência peptídica parecem estar diretamente relacionados à eficiência do processo; 3) o uso de alta temperatura agiliza o processo; 4) a geração de doadores de acila a partir de peptidil-2-CI-Trt empregando 1%TFA em DCM e misturas AcOH:TFE:DCM é simples e eficiente; 5) o uso combinado de DMF, do agente acoplador TBTU e de 60°C levou à agilização dos acoplamentos convergentes realizados, fornecendo os peptídeos desejados com boa qualidade em tempos relativamente menores; 6) vantagens e desvantagens da SCPFS em alta temperatura devem ser melhor avaliadas; 7) a SCPFS também apresenta limitações e problemas a serem contornados, o que demanda exploração sistemática empregando seqüências peptídicas e resinas variadas. / Stepwise solid-phase peptide synthesis (SSPPS) has been applied successfully for the preparation of most peptides containing up to 30 residues. However, it presents problems and limitations. Convergent soIid-phase peptide synthesis (CSPPS) can overcome part of them. This methodology is based on the synthesis of peptide segments by SSPPS followed by their condensations: the Nα- acylated protected segments act as acyl donors and the protected segments bound to the resin as acyl receptors. When the sequence is completed this is detached from the resin and fully deprotected to give the crude peptide. Besides developing other projectsfocused on peptide synthesis itself or on the use of synthetics to study biologically active peptides or proteins, we have systematically examined solid-phase peptide synthesis at elevated temperature. The aim of the present work was to investigate different aspects of convergent solid-phase peptide synthesis and examine the possibility to improve it at 60°C. Thus, unsulfated human cholecystokinin-33 and [Gln1]-gomesin were divided in three and two fragments, respectively. In the first case, the acyl donors were built-up by SSPPS on Kaiser oxime resin while in the second peptide elongation was done on 2-CI-Trt resin. The acyl receptor was synthesized and kept on the MBHA resin. The synthetic process was evaluated through characterization of every peptidyl-resin by amino acid analysis and of each crude peptide obtained from resin cleavage/full deprotection by RP-HPLC and LC/ESI-MS. The swelling degrees of the peptidyl-resins were determined in various solvents or mixtures of high boiling points. The peptidyl-KOR and peptidyl-2-CI-Trt were then submitted to peptide detachment under a few experimental conditions in order to release the Nα-acyl protected peptides (the acyl donors). Finally, their couplings with the acyl receptors were carried-out at 37 and 60°C in solvents or mixtures suitable for peptidyl-resin solvation containing specific coupling agents. The resulting peptidyl-resins were isolated, dried and submitted to HF treatment to release the corresponding unprotected crude peptides, which were analysed by RP-HPLC and LC/ESI-MS. The results found indicated that: 1) the knowledge of the swelling properties of the peptidyl-resins in different solvents systems is very useful in SCPFS. Indeed, it may guide the selection of experimental conditions to be used in peptide detachment from KOR and 2-CI-Trt and in segment condensation at elevated temperature, 2) peptide detachment from KOR is not as trivial as described (it was impossible to release hCCK-33 fragment 6-19 in its protected form). Further studies are certainly required to improve it. It seems that the size and the sequence are strictly related to the process efficiency, 3) high temperature can improve it, 4) peptide detachment from 2-CI-Trt is as simple as described, 5) combination of DMF as solvent, TBTU as coupling agent and 60°C was suited for the segment couplings studied: the reactions were completed in relatively short times and crude peptides of good quality were obtained, 6) this is the first attempt to carry-out CSPFS at elevated temperature, thus its advantages and disadvantages must be studied, 7) CSPPS also presents problems and limitations to overcome. Such task requires further investigation using various resins and peptide sequences.
494

Determinação de íons metálicos por FI-FAAS após separação e concentração em fase sólida: avaliação crítica de adsorventes / Determination of metallic ions by FI-FAAS after separation and preconcentration in solid-phase: critical evaluation of adsorbents

Anaia, Grazielle de Campos 29 February 2008 (has links)
Um procedimento de separação e pré-concentração em sistemas de análises em fluxo acoplado a espectrometria de absorção atômica com atomização em chama (FI-FAAS) é proposto para a determinação de Cu(II), Ni(II) e Cd(II). Diferentes adsorventes (XAD-7, sílica-gel e sílica funcionalizada C18) foram avaliados para a imobilização do reagente 1-(2-tiazolilazo)-2-naftol (TAN) que forma complexos com diversos íons metálicos. A avaliação e seleção do adsorvente baseou-se em isotermas de adsorção (Langmuir, Freundlich e Dubinin- Radushkevich (D-R)) e estudos de dessorção. O modelo de Langmuir indicou que a -2 -1 sílica-gel adsorve uma quantidade maior de TAN (1,81±0,08)x10-2 g g-1 em relação à XAD-7 (4,05±0,51)x10-3 g g-1 e à sílica funcionalizada C18 1,58x10-2 g g-1 . Pelo modelo de Freundlich, foi verificado que a superfície da XAD-7 apresenta elevada heterogeneidade energética dos sítios de adsorção evidenciado pelo parâmetro n de 2,57±0,08 contra 1,01±0,02 para sílica-gel. A constante de Freundlich foi de -1 (0,232±0,023) e (2,27±0,59) g g-1 para XAD-7 e sílica-gel, respectivamente. O modelo de D-R revelou que ocorre fisissorção para ambos os adsorventes. Estudos de dessorção permitiram concluir que a XAD-7 modificada apresentou a menor massa de TAN dessorvida em comparação com a sílica-gel, nas condições de acidez a serem empregadas nas etapas de retenção e eluição dos íons metálicos. Desta forma, XAD-7 imobilizada com o TAN foi selecionada para pré-concentração dos metais no sistema de análises em fluxo. Utilizando um amostrador temporizado eletronicamente, as variáveis vazão e concentração do eluente, pH de retenção, vazão e tempo de pré-concentração da amostra foram avaliadas. Na etapa de amostragem, os íons metálicos foram pré-concentrados por 300 s na forma de complexos com o TAN, empregando vazão de amostra de 6,2 mL min-1 e pH 7,5. A eluição foi efetuada com 0,2 mol L-1 HNO3 e vazão de 6,2 mL min-1 . O limite de detecção e o fator de enriquecimento foram estimados em 0,20 µg L-1 e 68; 1,5 µg L-1 e 15 e 0,060 µg L-1 e 44 para Cu(II), Ni(II) e Cd(II), respectivamente. Os coeficientes de variação foram estimados em 3,2%, 5,6% e 3,6% para Cu(II), Ni(II) e Cd(II), respectivamente. O procedimento proposto para FI não é adequado para a pré-concentração de metais em amostras contendo altas concentrações de íons cloreto, devido à formação de cloro-complexos, que prejudicam a formação de complexos com TAN na fase sólida. / A flow-based procedure for separation and preconcentration coupled to flame atomic absorption spectrometry (FI-FAAS) is proposed for determination of Cu(II), Ni(II) e Cd(II). Different sorbents (XAD-7, silica gel and C18 bonded silica) were evaluated for the immobilization of the reagent 1-(2-thiazolylazo)-2-naphthol (TAN), which reacts with several metal ions yielding complexes. The evaluation and selection of the adsorbent was based on adsorption isotherms (Langmuir, Freundlich and Dubinin-Radushkevich (D-R)) as well as desorption studies. The Langmuir model indicated that silica gel uptakes higher amount of TAN (1.81±0.08)x10-2 g g-1 as compared to (4.05±0.51)x10-3 g g-1 for XAD-7 and (1.58x10-2 ) g g-1 for C18 bonded silica. Based on the Freundlich model, it was verified that XAD-7 surface presented high energetic heterogeneity of the adsorption sites evidenced by the parameter n of 2.57±0.08 against 1.01±0.02 to silica gel. The Freundlich constant was 0.232±0.023 -1 and 2.27±0.59 g g-1 for XAD-7 and silica gel, respectively. The D-R model revealed that physical sorption occurred for both adsorbents. The modified XAD-7 showed the lowest desorbed mass in comparison to silica gel, in the same acidity conditions employed for retention and eluting steps of the metal ions. XAD-7 modified with TAN was thus selected to concentrate metal ions in the flow system. Using a time-based sample loading, the variables like eluent flow rate and concentration; pH in the retention step, sample flow rate and loading sample time were investigated. In the sampling step, the metal ions were preconcentrated for 300 s in the form of TAN complexes, employing a sample flow rate of 6.2 mL min-1 and pH 7.5. The elution was carried out with 0.2 mol L-1 HNO3 and flow rate of 6.2 mL min-1 . The detection limits and enrichment factors were estimated as 0.2 µg L-1 and 68; 1.5 µg L-1 and 15 and 0.060 µg L-1 and 44 for Cu(II), Ni(II) and Cd(II), respectively. The coefficients of variation were estimated as 3.2%, 5.6% and 3.6% for Cu(II), Ni(II) and Cd(II), respectively. The proposed procedure is not appropriate for the preconcentration of metals in samples containing high chlorides concentrations due to the formation of chloride-complexes that hinder the formation of the TAN-complexes on the solid phase.
495

Fettsäureethylester als Marker exzessiven Alkoholkonsums

Auwärter, Volker 27 February 2006 (has links)
In der vorliegenden Arbeit wurde ein analytisches Verfahren zur quantitativen Bestimmung von Fettsäureethylestern (FSEE) im Haar und in Hautoberflächenlipiden mittels Headspace-Festphasenmikroextraktion (HS-SPME) und Gaschromatographie-Massenspektrometrie (GC-MS) sowie eine auf Hochleistungs-Flüssigchromatographie mit Photodiodenarray-Detektion (HPLC-DAD) basierende Methode zur Bestimmung der Squalenkonzentrationen in Lipidextrakten entwickelt. Die bei Untersuchung von Proben verschiedener Konsumentengruppen erhaltenen Konzentrationswerte wurden hinsichtlich ihrer Eignung als Marker für chronisch exzessiven Alkoholkonsum untersucht. Aus den Ergebnissen lässt sich schließen, dass Fettsäureethylester im Haar als Alkoholmarker den bisher üblicherweise genutzten Markern wie GGT, CDT oder MCV bezüglich Sensitivität und Spezifität mindestens ebenbürtig sind. Es wurden die folgenden vorläufige Cut-off-Werte festgelegt: wenn sich im Haar für die Summenkonzentration der vier in der höchsten Konzentration vorkommenden FSEE (Ethylmyristat, Ethylpalmitat, Ethyloleat und Ethylstearat) ein Wert > 1 ng/mg ergibt, kann mit hoher Sicherheit von chronisch exzessivem Alkoholkonsum ausgegangen werden, für Abstinenzler werden typischerweise Werte < 0,4 ng/mg gefunden. Durch Bildung des Quotienten der FSEE-Konzentrationen und der Squalenkonzentrationen wurden relative FSEE-Konzentrationen erhalten, die im Falle der Haaranalyse zu einer Verbesserung der Zuordnungssicherheit zu den entsprechenden Konsumentengruppen führten bzw. bei der Analyse von Hautoberflächenlipiden einen sinnvollen Vergleich der Werte erst ermöglichten. Als vorläufiger Cut-off-Wert für die relativen FSEE-Konzentrationen wurde ein Wert von 2 ng/µg vorgeschlagen. Als weiteres wichtiges Ergebnis der Arbeit wurde der Einlagerungsmechanismus der FSEE ins Haar aufgeklärt. Es konnte gezeigt werden, dass Fettsäureethylester in erster Linie über das Sebum ins Haar gelangen. / The current doctoral thesis presents the development of an analytical procedure for the quantitative analysis of fatty acid ethyl esters (FAEE) in hair and in skin surface lipids using headspace solid phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS) as well as a method based on high-performance liquid chromatography with photodiode array detection (HPLC-DAD) to determine squalene concentrations in lipid extracts. The results obtained from analysis of samples from different alcohol consuming groups showed that FAEE are suitable markers for long-term alcohol misuse. Concerning sensitivity and specifity they are at least as good as other commonly used markers like GGT, CDT or MCV. The following provisional cut-off values were established: for chronically excessive alcohol consumption, the sum of the four FAEE (ethyl myristate, ethyl palmitate, ethyl oleate and ethyl stearate) found in the highest mean concentrations should be > 1 ng/mg in hair; for non-drinkers, concentrations < 0,4 ng/mg are typical. The quotient obtained by dividing the FAEE concentration by the squalene concentration was defined as the relative FAEE concentration, which provides a better classification of the samples regarding the consumer groups through hair analysis. Relative FAEE values also allow a reasonable comparison in the case of skin surface lipid concentrations for the first time. 2 ng/µg is suggested as a preliminary cut-off value. As a further important result of the current work, the mechanism of incorporation of FAEE into hair was clarified. It was shown that fatty acid ethyl esters are incorporated into hair mainly through sebum.
496

Avaliação da exposição de crianças a substâncias psicoativas durante a lactação através da análise toxicológica em leite materno / Evaluation of infant exposure to psychoactive substances during lactation by toxicological analysis in breast milk.

Silveira, Gabriela de Oliveira 13 June 2016 (has links)
O aleitamento materno está associado a benefícios de ordem nutricional, imunológica, afetiva, econômica e social. Grande parte das drogas lícitas e ilícitas consumidas pela lactante pode ser transferida para o leite, o que pode representar potenciais efeitos nocivos para a criança em curto e longo prazos. Embora o conhecimento a respeito de substâncias psicoativas durante a lactação venha sendo ampliado, ainda há poucas informações sobre as concentrações de substâncias excretadas por essa via e muitas dúvidas sobre os efeitos delas em crianças durante o período de amamentação. O leite materno é uma matriz não convencional que pode ser usada para avaliar a exposição de crianças a substâncias durante o aleitamento e sua principal vantagem é a coleta simples e não-invasiva. Contudo, a extração destas a partir do leite materno é um desafio analítico devido ao seu alto conteúdo lipídico e proteico, bem como a alteração na sua composição durante o período pós-parto. No presente trabalho, técnicas analíticas miniaturizadas foram desenvolvidas visando a detecção das substâncias psicoativas cocaína, cocaetileno, norcocaína, tetraidrocanabinol, canabinol, canabidiol em amostras de leite materno, utilizando cromatografia gasosa acoplada à espectrometria de massas (GC-MS). A microextração em fase líquida (LPME) foi aplicada para analitos de cocaína e a microextração em fase sólida (SPME) para canabinoides. Após o desenvolvimento e validação dos métodos, as análises foram aplicadas em amostras de leite coletadas no hospital municipal Dr. Arthur Ribeiro de Saboya (n=109). Além das técnicas terem se mostrado adequadas à extração e detecção dos analitos, confirmou-se a excreção de cocaína no leite materno em quantidades moderadas com resultado positivo para uma amostra (138 ng/mL). Bem como foi detectado tetraidrocanabinol nas concentrações de 20 ng/mL e 31 ng/mL em amostras de leite humano. / Maternal breastfeeding is related with nutritional, immunological, affective, economic, and social benefits. Most licit and illicit substances consumed by the nursing mother might be excreted in breast milk, which may cause potential harmful effects to the breastfed infant at short and long terms. Although the knowledge about the psychoactive substances during lactation is increasing, there is still few information on the levels in which these substances are excreted in breast milk and many questions about the possible effects of these substances in the infant during the nursing period still remain unanswered. Breast milk is an unconventional matrix that can be used to assess infant exposure to drugs, and its main advantage is its easy and non-invasive collection. However, the extraction of substances from breast milk is an analytical challenge because of its high protein and fat content and changing composition during the postpartum period. In this study, miniaturized analytical techniques will be carried out to determine psychoactive substances such as cocaine, cocaethylene, norcocaine, tetrahydrocannabinol, cannabinol, and cannabidiol in milk samples by using gas chromatography-mass spectrometry (GC-MS). Liquid-phase microextraction (LPME) was applied to cocaine analytes and solid-phase microextraction (SPME) was applied to cannabinoids. After the development and validation, the methods were applied in milk samples collected from municipal hospital Dr. Arthur Ribeiro de Saboya (n=109). These techniques have proved to be suitable for analyte extraction and detection. Cocaine excretion in breast milk has been confirmed given that one sample was positive to cocaine in moderate amounts (138 ng/mL), as well as, two samples could be confirmed positive to tetrahydrocannabinol at 20 ng/mL and 31 ng/mL.
497

Desenvolvimento de métodos de extração e determinação de bifenilas policloradas por cromatografia gasosa e detector de captura de elétrons em óleo Ascarel, reator anaeróbio e solo / Development and validation of a method for determination of Polychlorinated Biphenyls (PCBs) of a standard solution PCB Congener MIX 1 by gas chromatography and electron capture detector in three different matrices: Askarel oil, samples from batch anaerobic reactors and soil

Maria Angela Tallarico Adorno 23 August 2013 (has links)
Bifenilas policloradas (PCBs) são componentes de óleo ascarel, usado extensamente (no Brasil até os anos 80) como isolante em transformadores de energia devido às suas propriedades físico-químicas como estabilidade térmica e alta constante dielétrica. Apesar de ter sido proibido em todo o mundo devido à alta toxicidade dos PCBs presentes em sua composição, ainda resta grande quantidade de ascarel em circulação como resíduo \"passivo\" e resultante de contaminação em trocas dos fluidos dos transformadores, além de vazamentos. A principal forma de eliminação é por incineração, que, além de ser um processo caro, pode provocar a formação de compostos mais tóxicos, as dioxinas. Por isso é importante o monitoramento da concentração dessas substâncias, a fim de evitar maiores impactos ambientais na sua disposição, bem como em estudos de biodegradação. Esta matriz é extremamente complexa, o que torna a extração e determinação desses analitos um processo trabalhoso e difícil. Neste trabalho avaliaram-se métodos de extração e determinação de PCBs presentes na solução padrão comercial PCB Congener MIX 1, SUPELCO (PCBs 10, 28, 52, 138, 153 e 180). O desenvolvimento de métodos de extração (cromatografia em coluna, extração líquido-líquido (L-L), extração em fase sólida (SPE) e micro-extração em fase sólida - SPME) dos PCBs foi seguido da determinação, por cromatografia gasosa com detector por captura de elétrons (CG/DCE), em três matrizes diferentes: óleo ascarel, amostras provenientes de reatores anaeróbios em batelada e solo. Os métodos cuja purificação e extração diminuíram o efeito dos interferentes da matriz, como SPE - Sulfoxide, cromatografia em coluna de sílica e extração L-L com n-hexano foram validados pela avaliação dos seguintes parâmetros: linearidade e faixa de aplicação; precisão instrumental; limite de detecção, limite de quantificação e recuperação absoluta. O critério de escolha entre os métodos para extração dos PCBs do óleo que forneceram maior eficiência (cartucho SPE Sulfoxide e coluna de sílica gel, após lavagem ácida; método da adição de padrão, entre 1,0 e 4,0 mg L-1) deve considerar a disponibilidade de recursos, pois a sílica gel é mais viável economicamente do que o cartucho SPE. Os valores de R2 > 0,99 para o método de extração com sílica, mesmo tendo sido considerados apenas três pontos para a curva de calibração, atestam maior linearidade do que o método com SPE Sulfoxide (R2 entre 0,97 e 0,99). A extração L-L e determinação por CG/DCE dos PCBs (padronização interna) de amostras provenientes de reatores anaeróbios em batelada (aquosas, em matriz extremamente complexa com biomassa e espuma de poliuretano para imobilização de microrganismos) foram eficientes na faixa de concentração entre 0,05 e 0,5 mg L-1. Esse método foi adequado para monitorar PCBs em estudo de degradação anaeróbia e teste de adsorção dos PCBs em espuma; forneceu linearidade com R2 entre 0,93 e 0,96 e limites de detecção de 0,048 a 0,298 mg L-1, além de recuperação absoluta entre 14,1% e 110,7%. As condições testadas por SPME não permitiram a extração dos PCBs de óleo e de solo, principalmente devido à dessorção incompleta dos PCBs da fibra de polidimetil-siloxano, de 100 &#956;m. / Polychlorinated biphenyls (PCBs) are components of ascarel, oil widely used as insulation (until the \'80s in Brazil) due to its physicochemical properties such as thermal stability and high dielectric constant. Despite having been banned worldwide due to the high toxicity of PCBs present in its composition, there are still lots of outstanding ascarel as \"passive\" residue and resulting contamination of fluids in transformers exchanges, plus leaks. The main form of disposal is incineration, which, besides being costly, can cause the formation of more toxic compounds, that is, dioxins. It is therefore important to monitor the concentration of these substances in order to prevent further environmental impacts in their disposal, as well as in studies of biodegradation. This is an extremely complex matrix, which makes the extraction and determination of this analytes very difficult and labor intensive. In this work we have evaluated methods of extraction and determination of the PCBs present in the standard solution Congener MIX 1, SUPELCO (PCBs 10, 28, 52, 138, 153 e 180). The extraction and cleanup developed methods which reduced the effects of interfering matrix as solid phase extraction (SPE) - Sulfoxide, column chromatography on silica and liquid-liquid (L-L) extraction with n-hexane, and solid phase microextraction (SPME) after determination of the PCBs by gas chromatography with electron capture detector (GC/ECD) were validated by assessing the following parameters: linearity and range of application; instrumental precision; detection limit; limit of quantification and absolute recovery. The criterion for choosing between the methods for extraction of PCBs from the oil with a higher efficiency (SPE cartridge Sulfoxide and silica gel column, after acid washing; using the standard addition method, between 1.0 and 4.0 mg L-1) must evaluate the availability resources, since the silica gel is more economically viable than the SPE cartridge. The R2 values > 0.99 for silica extraction method, even though it was considered only three points for the calibration curve, attested higher linearity than the method with SPE Sulfoxide (R2 between 0.97 and 0.99). The L-L extraction and determination by GC/ECD of the PCBs (internal standardization) of samples from batch anaerobic reactors (aqueous, in a very complex matrix with biomass and polyurethane foam for the immobilization of microorganisms) were efficient in the concentration range between 0.05 and 0.5 mg L-1. This method was suitable to monitor PCBs in anaerobic degradation studies and its adsorption on foam; provided R2 linearity between 0.93 and 0.96 and detection limits from 0.048 to 0.298 mg L-1, as well as absolute recovery between 14.1% and 110.7%. The conditions tested for SPME technique did not allow the extraction of the PCBs from the oil and soil, mainly due to the \"incomplete dessorption\" of PCBs from the polydimethylsiloxane fiber of 100 micron.
498

Aplicação da cromatografia a gás associada à espectrometria de massas em tandem no diagnóstico da deficiência de 3&#946;-hidroxidesidrogenase / Application of gas chromatography coupled to tandem mass spectrometry in the diagnosis of 3&#946;-hidroxidesidrogenase deficiency

Presutti, Thais Rodrigues 10 April 2017 (has links)
Pregnenolona (PREG) e 17-alfa-hidroxipregnenolona (17OHPREG) são dois esteroides produzidos pela glândula adrenal e precursores de vários hormônios esteroidais. A dosagem desses compostos tem aplicações clínicas, como o diagnóstico de doenças relacionadas aos corticoesteroides e mineralocorticóides e especialmente na avaliação da atividade da enzima 3-&#946;-hidroxidesidrogenase que é decisiva no diagnóstico de um dos tipos de hiperplasia da glândula adrenal que causa defeitos severos na síntese de esteroides. Métodos cromatográficos associados à espectrometria de massas superaram a especificidade reduzida dos imunoensaios e tem sido crescentemente utilizados na quantificação de esteroides. Os últimos anos tem sido marcados pela hegemonia da cromatografia líquida acoplada à espectrometria de massas em tandem (LC-MS/MS) em grande parte devido à velocidade e possibilidade da análise direta de vários analitos. Porém, no caso específico dos esteroides de tipo 3-hidroxi-5-eno, que apresentam baixa afinidade protônica e, portanto, baixa eficiência de ionização, são necessárias muitas etapas para a conversão em derivados mais detectáveis. Embora desfavorecida em relação ao LC-MS/MS nos últimos anos, a cromatografia gasosa acoplada à espectrometria de massas (CG-MS) apresenta várias características favoráveis para a análise de esteroides como a eficiência cromatográfica ainda insuperável. Adicionalmente, a incorporação da espectrometria de massas em tandem ao CG (CG-MS/MS) torna a técnica tão seletiva quanto LC-MS/MS. No presente trabalho, foi desenvolvido um novo método que permite a extração e derivatização simultâneas da PREG e 17OHPREG de amostras de soro tornando o método de preparo da amostra tão simples quanto os descritos para LC-MS/MS. O método de detecção desenvolvido baseado em ionização química no modo negativo obteve a sensibilidade necessária para o diagnóstico da deficiência da enzima 3-beta-hidroxidesidrogenase utilizando apenas 250 &#181:L de amostra. / Pregnenolone (PREG) and 17&#945;-hydroxypregnenolone (17OHPREG) are two steroid precursors produced by the adrenal gland. The quantification of these compounds is essential for the evaluation of 3-&#946;-hidroxidesidrogenase enzyme activity, which promotes the conversion of PREG in 17OHPREG. The 3-&#946:-hidroxidesidrogenase deficiency is a rare but severe type of adrenal hyperplasia that causes serious defects in steroid synthesis. Chromatographic methods coupled to mass spectrometry overcame immunoassays limitations such as reduced specificity, and have been widely used for steroids quantification. Recent years have been marked by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) hegemony due to the speed and possibility to analyze directly several analytes. However, in the case of type 3-hydroxy-5-ene steroids, which have low affinity for protons and, therefore, low ionization efficiency, many steps are required for conversion to detectable products. Notwithstanding, gas chromatography coupled to mass spectrometry (GC-MS) has some favorable features for steroid analysis such as unbeatable chromatographic efficiency. In addition, the incorporation of tandem mass spectrometry (GC-MS/MS) makes it as selective as LC-MS/MS. In this study, a new method for simultaneous extraction and derivatization of PREG and 17OHPREG from serum was developed. This procedure makes sample preparation for GC-MS/MS as simples as those described for LC-MS/MS. The detection method based on negative mode chemical ionization achieved the sensitivity required for the diagnosis of 3-&#946;-hidroxidesidrogenase defficiency using only 250 &#181;L of sample.
499

Desenvolvimento de procedimento analítico para a determinação de ácido salicílico em materiais vegetais explorando cromatografia por injeção sequencial / Development of an analytical procedure for the determination of salicylic acid in plant materials exploiting sequential injection chromatography

Barrientos, Marcia Otto 24 July 2015 (has links)
A cromatografia por injeção sequencial com extração em fase sólida (EFS) em linha foi explorada para a determinação de ácido salicílico em amostras vegetais. Uma mini coluna de polietileno, preenchida com sílica funcionalizada C18, foi utilizada para EFS, com tampão fosfato pH 5,2 como eluente. O eluato foi diretamente transferido para a separação cromatográfica em uma coluna monolítica C18, utilizando solução de acetonitrila/tampão acetato pH 4,75 (5:95, v/v) como fase móvel. A detecção foi realizada por fluorescência com excitação em 298 nm e emissão em 406 nm. Os sinais analíticos foram baseados na altura do pico cromatográfico referente ao ácido salicílico em um tempo de retenção de 9.0 min. Os limites de detecção (99,7% de confiança) e quantificação foram estimados em 80 e 240 ?g L-1, respectivamente. A precisão foi estimada através do coeficiente de variação intradia (n = 10) em 0,99% e interdia (3 dias) em 3,6%. A resposta foi linear até 8,0 mg L-1 (r = 0,996). A resolução em relação aos demais componentes da matriz, o número de pratos e a altura equivalente a um prato foram estimados em 6,0; 3980 e 12,6 ?m, respectivamente. Utilizando calibração pelo método das adições de padrão, foram estimadas recuperações entre 74,2 e 96,4% em 4 amostras de folhas de soja. Com estes resultados conclui-se que o procedimento é adequado à determinação de ácido salicílico nos materiais vegetais com a remoção de interferentes em linha, tendo as vantagens de ser um procedimento rápido (ca. 17 min por determinação), limpo (consumo de ca. 320 ?L de acetonitrila por determinação), de custo relativamente baixo, suficientemente sensível e seletivo / Sequential injection cromatography with on-line solid phase extraction (SPE) was explored for the determination of salicylic acid in vegetable samples. A polyethylene column filled with C18-bonded silica was used for SPE, with a phosphate buffer pH 5.2 as eluent. The treated extract was directly sent towards chromatographic separation in a C18 monolithic column with an acetonitrile/acetate buffer solution, pH 4,75 (5:95, v/v) as mobile phase before fluorescence detection (excitation at 298 nm and emission at 406 nm). The analytical signals were based on peak height at the 9.0 min retention time. Limits of detection (99.7% confidence level) and quantification were estimated at 80 and 240 ?g L-1. Precision was estimated through intraday coefficient of variation (n = 10) at 0.99% and interday (3 days) at 3.6 %. A linear response up to 8.0 mg L-1 was estimated (r = 0.996). Resolution, number of plates and the height equivalent to one plate were estimated at 6.0, 3980 and 12,6 ?m, respectively. With calibration by the standard additions method recoveries within 74.2 and 96.4 % were estimated to four soy leaves samples. Thus, the procedure is suitable for the determination of salicylic acid in the extracts with on-line removal of interferences, being a rapid (ca. 17 min per determination), clean (ca. 320 ?L of acetonitrile by determination), inexpensive, and suitably sensitive and selective
500

Metodologias para determinação de fármacos, metabólitos e disruptores endócrinos em água de abastecimento público utilizando técnicas de separação em meio líquido (CE/UV, CE-MS, LC-MS/MS) / Methods for determination of pharmaceuticals, their metabolites and endocrine disruptors in surface water using separation techniques in liquid media (CE/UV, CE-MS, HPLC-MS/MS)

Costa, Ana Carolina de Oliveira 03 December 2009 (has links)
Este trabalho apresenta o desenvolvimento e validação de métodos analíticos para investigar a presença de fármacos e seus metabólitos, assim como disruptores endócrinos, em amostras de águas superficiais, utilizando estratégias de \"clean up\" e enriquecimento de amostra no modo \"on line\" (\"stacking\") e \"off line\" (extração em fase sólida, SPE), em junção com técnicas de separação avançadas em meio líquido (eletroforese capilar, CE, e cromatografia a líquido, LC, com detecção UV, e seus acoplamentos com espectrometria de massas). No primeiro Capítulo são discutidos aspectos gerais sobre os produtos farmacêuticos, produtos de higiene pessoal e disruptores endócrinos, bem como a origem e ocorrência destas substâncias no meio ambiente. O segundo Capítulo aborda o desenvolvimento de um método de separação capaz de determinar oito substâncias entre fármacos de caráter ácido e metabólitos (diclofenaco, bezafibrato, fenoprofeno, ibuprofeno, cetoprofeno, naproxeno e ácidos gentísico e salicílico) numa única corrida, utilizando eletroforese capilar com enriquecimento em linha da amostra (stacking do analito baseado em grande volume de injeção da amostra) utilizando eletrólito de corrida constituído por 30 mmol L-1 de tetraborato de sódio e 5 mmol L-1 de Brij 35, pH 9,3. O método proposto alcançou limites de detecção que variaram de 2 &#181;g L-1 para o fármaco naproxeno até 80 &#181;g L-1 para o ibuprofeno. No terceiro capítulo é explorado um método de separação por CE para nove substâncias entre fármacos e hormônios (fluoxetina, trimetoprima, diazepam, carbamazepina, propranolol, clofibrato, fenofibrato, etinilestradiol e estrona). Utilizou-se como estratégia de pré-concentração dos analitos, o modo \"stacking\" de micelas com grande volume de injeção de amostra. Este método chegou a limites de detecção na ordem de 9 &#181;g L-1 com eletrólito de corrida composto por 30 mmol L-1 de ácido fosfórico, 40 mmol L-1 de dodecilsulfato de sódio, 20% (v,v) de acetonitrila e 0,1% (v,v) de trietilamina. No quarto capítulo, foi realizado o estudo de parâmetros físico-químicos que estão relacionados à técnica de extração em fase sólida, tais como tipo do sorvente, volume de capacidade, volume de eluição, lavagem do cartucho de extração, entre outros. As condições ótimas de \"clean up\" e pré-concentração \"off line\" da amostra obtidas foram combinadas com as condições ótimas de pré-concentração \"on line\" e separação descritas nos Capítulos 2 e 3, para todas as substâncias abordadas ali, com o intuito de analisar amostras reais de água superficial coletadas no reservatório Billings (Estado de São Paulo). O método combinado permitiu alcançar concentrações da ordem de 500 ng L-1, com valores de recuperação satisfatórios (58 - 88%), quando levada em consideração a origem complexa da matriz ambiental. No quinto capítulo, desenvolveu-se um método de análise de p-hidroxibenzoatos de alquila, substâncias utilizadas como conservantes em diversos produtos de uso diário, utilizando eletroforese capilar associada a estratégias de concentração \"on line\" (stacking com injeção de grande volume de amostra) e \"off line\" (SPE). O método proposto, utilizando eletrólito constituído por 40 mmol L-1 de glicina e 40 mmol L-1 de trietilamina, foi aplicado na análise destas substâncias em amostras de água superficial, alcançando níveis de concentração da ordem de 4 6 &#181;g L-1. O sexto capítulo aborda o desenvolvimento de um método por eletroforese capilar destinada à análise de alquilbenzeno sulfonato linear (LAS) e homólogos, tensoativo comumente utilizado na composição de detergentes de uso doméstico e industrial. O eletrólito de separação era composto de 60 mmol L-1 TRIS, 30 mmol L-1 HIBA, 15 mmol L-1 Brij 35 e 40% (v,v) acetonitrila. Foi realizada uma etapa de extração em fase sólida (C18), e uma concentração total de LAS na ordem de 1,09 mg L-1 foi encontrada em uma amostra de efluente de estação de tratamento de esgoto. No capítulo 7 foi desenvolvido um método utilizando eletroforese capilar acoplada a um espectrômetro de massas, com analisador \" ion trap\", para a análise dos fármacos cimetidina, propranolol, salbutamol, trimetoprima e metoclopramida. Amostras de água coletadas no reservatório Billings foi fortificada com os fármacos em estudo e submetida a procedimento de extração em fase sólida em cartuchos de poliestireno divinilbenzeno (PS-DVB). O método permitiu a análise das substâncias estudadas na concentração aproximada de 40 &#181;g L-1. Finalmente, no oitavo capítulo foi explorado um método envolvendo cromatografia líquida de alta eficiência, hifenada a dois tipos de espectrômetros de massas: um triplo quadrupolo e um triplo quadrupolo com \"ion trap\" linear. Foram investigados fármacos de diversas classes em amostras de água coletadas no reservatório Billings, sendo possível encontrar carbamazepina na concentração de 20 ng L-1, com apenas uma etapa de filtração da amostra antecedendo a análise, utilizando o triplo quadrupolo. Cabe destacar que o LOD para este analito foi de 400 fg L-1, sem nenhum tratamento da amostra visando préconcentração. / This work presents the development and validation of analytical methods to investigate the presence of pharmaceutical compounds, their metabolites and endocrine disruptors in surface water using on line (stacking) and off line (solid phase extraction) sample clean up and enrichment strategies coupled to advanced separation techniques in liquid medium (capillary electrophoresis and liquid chromatography with UV detection and their hyphenation with mass spectrometry). In the first Chapter, general aspects on pharmaceuticals, products of personal care and endocrine disruptors are discussed as well as their origin and means of entry to the environment. Chapter 2 describes the development of a separation method for the determination of eight pharmaceuticals and endocrine disruptors substances with acidic character (diclofenac, bezafibrate, fenoprofen, ibuprofen, ketoprofen, naproxen, gentisic and salicylic acids) in a single run using capillary electrophoresis with on line sample enrichment (analyte stacking with large sample volume injection) in electrolytes composed of 30 mmol L-1 sodium tetraborate at pH 9.3 and 5 mmol L-1 Brij 35. The proposed method reached limits of detection between 2 &#181;g L-1 (naproxen) and 80 &#181;g mL-1 (ibuprofen). In Chapter 3, a CE separation method for the determination of nine pharmaceuticals and hormones with neutral and basic character (fluoxetin, trimethoprim, diazepam, carbamazepine, propranolol, clofibrate, fenofibrate, ethynylestradiol and estrone) was exploited. As preconcentration strategy, micelle stacking with large sample volume injection was performed. Limits of detection in the order of 9 &#181;g L-1 were reached with electrolytes composed of 30 mmol L-1 phosphoric acid, 40 mmol L-1 sodium dodecylsulfate, 20% (v,v) acetonitrile and 0.1% (v,v) triethylamine. In Chapter 4, the physicochemical parameters associated with the solid phase extraction technique, such as sorbent type, breakthrough volume, elution volume, extraction cartridge rinse, among others, were evaluated. Optimum sample clean up and off line preconcentration conditions combined with the optimum on line preconcentration and separation conditions described in Chapters 2 and 3, for all substances under consideration, were applied to the analysis of real surface water samples collected at the Reservoir Billings (Sao Paulo state, Brazil). The combined method reached concentrations in the order of 500 ng L-1, with satisfactory recoveries (58 88%) for complex environmental matrices. In Chapter 5, a method for the analysis of alkyl p-hydroxybenzoates, substances used as preservatives in several products of personal care, was developed using capillary electrophoresis associated with on line (stacking with large volume injection) and off line (SPE) preconcentration strategies. The proposed method, which used 40 mmol L-1 glycine and 40 mmol L-1 triethylamine as electrolyte, was applied to the analysis of alkyl p-hydroxybenzoates in surface water, reaching 4 - 6 &#181;g L-1 concentrations. Chapter 6 describes the development of a CE method for de analysis of linear alkylbenzene sulfonates (LAS) and homologues, surfactants commonly used in the composition of detergents of industrial and domestic use. As separation electrolyte, 60 mmol L-1 TRIS, 30 mmol L-1 HIBA, 15 mmol L-1 Brij 35 and 40% (v,v) acetonitrile was used. A solid phase preconcentration extraction step in C18 was employed and a total LAS concentration of 1.09 mg L-1 was found in a sample obtained from the effluent of a sewage treatment plant. In Chapter 7, a CE-MS (ion trap) method was developed for the analysis of cimetidine, propranolol, salbutamol, trimethoprim and methoclopramide in fortified surface water samples collected in the Reservoir Billings (Sao Paulo state, Brazil) and previously enriched by SPE (PS-DVB). The method reached concentrations of c.a. 40 &#181;g L-1. Finally, in Chapter 8, a method based on high-performance liquid chromatography coupled with two different mass spectrometers: a triple quadrupole and a triple quadrupole with linear ion trap). Several pharmaceuticals were investigated in surface water samples collected from the Reservoir Billings (Sao Paulo state, Brazil). With the LC-MS/MS (triple quadrupole) system, carbamazepine was found in a non treated sample (just a filtration step prior to injection was performed) in a concentration level of 20 ng L-1. It is worth mentioning that for carbamazepine, a LOD of 400 fg L-1 was found, without any preconcentration sample treatment

Page generated in 0.0689 seconds