• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 250
  • 117
  • 51
  • 39
  • 30
  • 10
  • 6
  • 5
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 627
  • 627
  • 260
  • 177
  • 163
  • 163
  • 123
  • 115
  • 113
  • 111
  • 109
  • 108
  • 102
  • 92
  • 78
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
501

Avaliação das técnicas de microextração e eletroforese capilar em meio não aquoso (NACE) para determinação de antidepressivos em amostras de plasma para fins de monitorização terapêutica / Evaluation of microextractions techniques and nonaqueous capillary electrophoresis (NACE) for the determination of antidepressants in plasma samples for therapeutic drug monitoring

Catai, Ana Paula Formenton 02 March 2012 (has links)
A monitorização terapêutica tem sido descrita como um recurso clínico valioso, na individualização do regime de dosagem, de acordo com a concentração do fármaco em amostras de plasma ou soro. O objetivo da monitorização terapêutica é assegurar a eficácia clínica e minimizar os efeitos adversos dos fármacos prescritos na clínica. A química analítica moderna tem sido direcionada para a simplificação dos métodos através da miniaturização dos sistemas analíticos, minimização do consumo de solvente orgânico e do volume da amostra. Neste contexto, metodologias analíticas utilizando as técnicas de microextração, extração sortiva em barra de agitação (SBSE) e microextração em sorvente empacotado (MEPS), juntamente com a eletroforese capilar em solução não-aquosa (NACE) foram desenvolvidas para fins monitorização terapêutica de antidepressivos inibidores seletivos da recaptação de serotonina (ISRSs: fluoxetina, sertralina, paroxetina e citalopram) em amostras de plasma de pacientes em terapia com ISRSs. Inicialmente foram padronizadas as condições eletroforéticas com detecção espectrofotométrica (UV) para análise simultânea dos ISRSs em amostras de plasma. Dentre as condições avaliadas (diferentes soluções de eletrólitos em meio aquoso e não aquoso, cromatografia eletrocinética micelar e NACE), a técnica NACE-UV foi a única que apresentou resolução dos fármacos adequada. Em seguida, otimizou-se as variáveis inerentes das técnicas de microextração (SBSE e MEPS), visando minimizar o tempo de análise e aumento da sensibilidade analítica. Para o método SBSE/NACE, as variáveis tempo e temperatura de extração, pH da amostra biológica e processo de dessorção foram otimizadas, já para o método MEPS/NACE, as variáveis, pH da amostra biológica, volume da amostra e número dos ciclos aspirar/dispensar foram otimizadas. A validação analítica foi realizada segundo as normas preconizadas pela Agência Nacional de Vigilância Sanitária (ANVISA), com adição de padrão de padrão interno às amostras de plasma enriquecidas com os antidepressivos em diferentes concentrações plasmáticas que contemplam o intervalo terapêutico dos ISRSs. Para avaliar a aplicabilidade das metodologias padronizadas, amostras de plasma de pacientes em terapia com os ISRSs foram analisadas. Os métodos padronizados (SBSE/NACE e MEPS/NACE) foram comparados ao método de referência (LLE/NACE), utilizando a extração líquido-líquido. As técnicas de microextração, quando comparadas à LLE, apresentaram as seguintes vantagens: a reutilização das fases extratoras, procedimentos de extração com reduzido número de etapas, menores volumes de amostras biológicas e de solventes orgânicos. Segundo os parâmetros de validação avaliados, os métodos SBSE/NACE e MEPS/NACE padronizados podem ser empregados nas análises dos antidepressivos (ISRSs) em amostras de plasma, para fins de monitorização terapêutica. / Therapeutic monitoring allows individualization of the dose regimen and has been indicated for the monitoring of well-established therapeutic intervals. In psychiatric disorders, most of the patients require that the plasmatic concentrations to be within a fixed range, so the disorders are kept under control and the adverse effects are acceptable. The aim of the therapeutic monitoring is ensure clinical effectiveness and minimization of adverse effects of drugs prescribed at the clinic. New trends in analytical chemistry have been directed towards simplification and miniaturization of analytical systems, and minimization of organic solvents and sample volume. In this work, analytical methodologies using microextraction techniques, such as stir bar sorptive extraction (SBSE) and microextraction by packed sorbent (MEPS), in conjunction with capillary electrophoresis in a nonaqueous background electrolyte (NACE) were developed for therapeutic drug monitoring of selective serotonin reuptake inhibitors (SSRIs: fluoxetine, sertraline, paroxetine and citalopram) in plasma sample of patients in therapy with SSRIs. First, the optimization of electrophoretic separation of the SSRIs was carried out to obtain simultaneous analysis of all antidepressants. Among the conditions evaluated (different background electrolytes in aqueous and nonaqueous medium, micellar electrokinetic capillary chromatography, and NACE), NACE-UV gave the best results. In the sequence, the optimization of the inherent variables of microextraction techniques (SBSE and MEPS)aiming analyses time minimization and increase of analytical sensibilitywas carried out. For SBSE/NACE methodology development the variables such as time of extraction, temperature of extraction, and matrix pH were optimized. For MEPS/NACE methodology the variables matrix pH and the volume of draw-eject cycles were optimized. Analytical validation was carried out in agreement with the norms of National Health Surveillance Agency (ANVISA) for both of the proposed methods, in different plasmatic concentrations, which completed the therapeutic interval. The developed methods (SBSE/NACE e MEPS/NACE) were compared to the reference method, using liquid-liquid extraction (LLE/NACE). Microextraction techniques, compared to LLE, gave the following advantages: reutilization of the extraction phase, fewer numbers of steps for extraction, reduction of sample volume, and less consumption of organic solvents. According to the evaluated validation parameters, the standardized methods SBSE/NACE and MEPS/NACE can be used in the analyses of antidepressants (SSRIs) in plasma sample for therapeutic drug monitoring purposes.
502

\"Verificação da janela de detcção do etilglicuronídeo urinário entre usuários crônicos e bebedores sociais de etanol por cromatografia em fase gasosa acoplada à espectrometria de massas\" / Detection range verification of urinary ethyl glucuronide between chronic ethanol users and social drinkers by gas chromatography/mass spectrometry analysis

Marin, Ana Verónica Flores 06 July 2006 (has links)
A janela de detecção de etilglicuronídeo (EtG) parece variar de acordo com a intensidade de consumo de etanol. Assim sendo, o objetivo do presente trabalho foi desenvolver e validar uma metodologia empregando extração em fase sólida e GC-MS para a determinação de EtG urinário, no sentido de verificar sua janela de detecção entre um grupo de bebedores sociais e usuários crônicos. Os limites de detecção e quantificação obtidos foram 0,1 e 0,2 mg/L respectivamente. O método proposto demonstrou ser linear no intervalo de 0,2 a 100,0 mg/L (r2>0,99), exato e preciso. A janela de detecção de EtG em amostras de urina de cinco voluntárias após ingestão única e controlada de 0,5 g/kg de etanol variou de 24 a 35 horas. Amostras de urina foram coletadas de 14 pacientes internados em clínica de recuperação. Os resultados mostraram que a maioria deles provavelmente consumiu etanol, prejudicando a interpretação dos resultados. Nos casos em que a concentração urinária de EtG foi decaindo no decorrer do tempo, a janela de detecção variou de 72 a 120 horas. O método mostrou ser útil para monitorar a abstinência durante o tratamento de pacientes dependentes de etanol ou o consumo após uma única exposição em baixa dose. / The detection range of the ethylglicuronide (EtG) seems to vary in accordance to the intensity of ethanol consumption. Thus, the objective of the present work was to develop and validate a method using extraction in solid phase and GCMS for the determination of urinary EtG, in order to verify its detection window in a group of social drinkers and chronic ethanol users. The limits of detection and quantification were 0,2 and 0.1 mg/L, respectively. The method showed to be linear in the interval of 0,2 to 100,0 mg/L (r2>0,99), and presented good accuracy and precision. The urinary EtG detection range in samples of five volunteers after controlled ingestion of 0,5 g/kg of ethanol varied between 24 to 35 hours. Urine samples were also collected from 14 patients from a recovery clinic. The results showed that the majority of them probably consumed ethanol, which compromised the interpretation of the results. In the cases where the urinary concentration of EtG decayed with time, the detection window varied from 72 to 120 hours. The method showed to be useful to monitor the ethanol abstinence during treatment of alcoholic patients or the consumption of only one ethanol low dose.
503

Desenvolvimento de procedimento analítico para a determinação de ácido salicílico em materiais vegetais explorando cromatografia por injeção sequencial / Development of an analytical procedure for the determination of salicylic acid in plant materials exploiting sequential injection chromatography

Marcia Otto Barrientos 24 July 2015 (has links)
A cromatografia por injeção sequencial com extração em fase sólida (EFS) em linha foi explorada para a determinação de ácido salicílico em amostras vegetais. Uma mini coluna de polietileno, preenchida com sílica funcionalizada C18, foi utilizada para EFS, com tampão fosfato pH 5,2 como eluente. O eluato foi diretamente transferido para a separação cromatográfica em uma coluna monolítica C18, utilizando solução de acetonitrila/tampão acetato pH 4,75 (5:95, v/v) como fase móvel. A detecção foi realizada por fluorescência com excitação em 298 nm e emissão em 406 nm. Os sinais analíticos foram baseados na altura do pico cromatográfico referente ao ácido salicílico em um tempo de retenção de 9.0 min. Os limites de detecção (99,7% de confiança) e quantificação foram estimados em 80 e 240 ?g L-1, respectivamente. A precisão foi estimada através do coeficiente de variação intradia (n = 10) em 0,99% e interdia (3 dias) em 3,6%. A resposta foi linear até 8,0 mg L-1 (r = 0,996). A resolução em relação aos demais componentes da matriz, o número de pratos e a altura equivalente a um prato foram estimados em 6,0; 3980 e 12,6 ?m, respectivamente. Utilizando calibração pelo método das adições de padrão, foram estimadas recuperações entre 74,2 e 96,4% em 4 amostras de folhas de soja. Com estes resultados conclui-se que o procedimento é adequado à determinação de ácido salicílico nos materiais vegetais com a remoção de interferentes em linha, tendo as vantagens de ser um procedimento rápido (ca. 17 min por determinação), limpo (consumo de ca. 320 ?L de acetonitrila por determinação), de custo relativamente baixo, suficientemente sensível e seletivo / Sequential injection cromatography with on-line solid phase extraction (SPE) was explored for the determination of salicylic acid in vegetable samples. A polyethylene column filled with C18-bonded silica was used for SPE, with a phosphate buffer pH 5.2 as eluent. The treated extract was directly sent towards chromatographic separation in a C18 monolithic column with an acetonitrile/acetate buffer solution, pH 4,75 (5:95, v/v) as mobile phase before fluorescence detection (excitation at 298 nm and emission at 406 nm). The analytical signals were based on peak height at the 9.0 min retention time. Limits of detection (99.7% confidence level) and quantification were estimated at 80 and 240 ?g L-1. Precision was estimated through intraday coefficient of variation (n = 10) at 0.99% and interday (3 days) at 3.6 %. A linear response up to 8.0 mg L-1 was estimated (r = 0.996). Resolution, number of plates and the height equivalent to one plate were estimated at 6.0, 3980 and 12,6 ?m, respectively. With calibration by the standard additions method recoveries within 74.2 and 96.4 % were estimated to four soy leaves samples. Thus, the procedure is suitable for the determination of salicylic acid in the extracts with on-line removal of interferences, being a rapid (ca. 17 min per determination), clean (ca. 320 ?L of acetonitrile by determination), inexpensive, and suitably sensitive and selective
504

Degradação de profenofós em solução aquosa e em ervilhas processadas por feixe de elétrons e a síntese de polímeros impressos para extração seletiva desse pesticida / Degradation of profenofos in aqueous solution and peas by electron beam processed and synthesis of imprinted polymers for selective extraction of this pesticide

Flavio Thihara Rodrigues 10 April 2015 (has links)
Profenofós é um organofosforado empregado como inseticida e acaricida amplamente utilizado no Brasil para o controle de pragas de cebolas, milho, soja, café, tomate, algodão, feijão, batata e outros. A irradiação é um processo empregado em todo o mundo e recomendada por diversos órgãos de saúde para a conservação de alimentos. A radiação ionizante utiliza raios gama, raios X ou aceleradores de elétrons e tem sido aplicada para eliminar ou reduzir a ação de agentes patogênicos e contribuir para aumentar o tempo de estocagem de vários alimentos. Os objetivos desse trabalho foram: (a) avaliar a degradação de soluções aquosas de profenofós submetidas à radiação ionizante, identificar e quantificar a formação de novos produtos por GC-MS; (b) analisar o efeito de feixe de elétrons em ervilhas inoculadas com soluções aquosas de profenofós; (c) sintetizar Polímeros Molecularmente Impressos (MIP) e Sílica Impressa Molecularmente (MIS), posteriormente, caracterizar os adsorventes em fase sólida e verificar sua seletividade para profenofós. O tratamento com aceleradores de elétrons com dose 31,6 kGy promoveu a formação de um novo produto de degradação e redução de 93,40 % de profenofós em soluções aquosas. Em ervilhas inoculadas com 1 μg de profenofós submetidas à radiação ionizante de 30,4 kGy promoveu uma redução na concentração de profenofós em 57,46 %. Além disso, foram realizadas sínteses de MIP e MIS para a extração em fase sólida de profenofós. Os MIS sintetizados por sol-gel mostraram-se eficazes para o reconhecimento molecular e extração seletiva de profenofós. / Profenofos is an organophosphate widely used in Brazil as insecticide and acaricide in the control of pests in onions, corn, soybeans, coffee, tomato, cotton, beans, potatoes among others. Irradiation is a process used worldwide and recommended by many health agencies for food preservation. Food irradiation preserving process uses accelerated electrons, gamma rays or X-rays. Ionizing radiation treatment is applied to eliminate or to reduce the action of pathogens and to increase the shelf life of some foods. The objective of this study were (a) to evaluate the degradation of aqueous solutions of Profenofos by ionizing radiation, identify and quantify the formation of new products by GC-MS; (b) to analyze the effects of electron beam in peas inoculated with aqueous solutions of Profenofos; (c) to synthesize Molecularly Imprinted Polymer (MIP) and Molecularly Imprinted Silica (MIS), subsequently characterize the adsorbents in solid phase and check its selectivity for profenofos. The treatment with electron accelerators with 31.6 kGy dose promoted the formation of a new by-product and 93.40 % reduction of profenofos in aqueous solutions. In peas inoculated with 1 μg of profenofos by ionizing radiation of 30.4 kGy promoted a reduction of 57.46 % in the concentration of profenofos. Furthermore, the MIP and MIS were performed for solid phase extraction of profenofos. The MIS synthesized by sol-gel proved to be effective for the recognition molecular and selective extraction of profenofos.
505

Avaliação da exposição de crianças a substâncias psicoativas durante a lactação através da análise toxicológica em leite materno / Evaluation of infant exposure to psychoactive substances during lactation by toxicological analysis in breast milk.

Gabriela de Oliveira Silveira 13 June 2016 (has links)
O aleitamento materno está associado a benefícios de ordem nutricional, imunológica, afetiva, econômica e social. Grande parte das drogas lícitas e ilícitas consumidas pela lactante pode ser transferida para o leite, o que pode representar potenciais efeitos nocivos para a criança em curto e longo prazos. Embora o conhecimento a respeito de substâncias psicoativas durante a lactação venha sendo ampliado, ainda há poucas informações sobre as concentrações de substâncias excretadas por essa via e muitas dúvidas sobre os efeitos delas em crianças durante o período de amamentação. O leite materno é uma matriz não convencional que pode ser usada para avaliar a exposição de crianças a substâncias durante o aleitamento e sua principal vantagem é a coleta simples e não-invasiva. Contudo, a extração destas a partir do leite materno é um desafio analítico devido ao seu alto conteúdo lipídico e proteico, bem como a alteração na sua composição durante o período pós-parto. No presente trabalho, técnicas analíticas miniaturizadas foram desenvolvidas visando a detecção das substâncias psicoativas cocaína, cocaetileno, norcocaína, tetraidrocanabinol, canabinol, canabidiol em amostras de leite materno, utilizando cromatografia gasosa acoplada à espectrometria de massas (GC-MS). A microextração em fase líquida (LPME) foi aplicada para analitos de cocaína e a microextração em fase sólida (SPME) para canabinoides. Após o desenvolvimento e validação dos métodos, as análises foram aplicadas em amostras de leite coletadas no hospital municipal Dr. Arthur Ribeiro de Saboya (n=109). Além das técnicas terem se mostrado adequadas à extração e detecção dos analitos, confirmou-se a excreção de cocaína no leite materno em quantidades moderadas com resultado positivo para uma amostra (138 ng/mL). Bem como foi detectado tetraidrocanabinol nas concentrações de 20 ng/mL e 31 ng/mL em amostras de leite humano. / Maternal breastfeeding is related with nutritional, immunological, affective, economic, and social benefits. Most licit and illicit substances consumed by the nursing mother might be excreted in breast milk, which may cause potential harmful effects to the breastfed infant at short and long terms. Although the knowledge about the psychoactive substances during lactation is increasing, there is still few information on the levels in which these substances are excreted in breast milk and many questions about the possible effects of these substances in the infant during the nursing period still remain unanswered. Breast milk is an unconventional matrix that can be used to assess infant exposure to drugs, and its main advantage is its easy and non-invasive collection. However, the extraction of substances from breast milk is an analytical challenge because of its high protein and fat content and changing composition during the postpartum period. In this study, miniaturized analytical techniques will be carried out to determine psychoactive substances such as cocaine, cocaethylene, norcocaine, tetrahydrocannabinol, cannabinol, and cannabidiol in milk samples by using gas chromatography-mass spectrometry (GC-MS). Liquid-phase microextraction (LPME) was applied to cocaine analytes and solid-phase microextraction (SPME) was applied to cannabinoids. After the development and validation, the methods were applied in milk samples collected from municipal hospital Dr. Arthur Ribeiro de Saboya (n=109). These techniques have proved to be suitable for analyte extraction and detection. Cocaine excretion in breast milk has been confirmed given that one sample was positive to cocaine in moderate amounts (138 ng/mL), as well as, two samples could be confirmed positive to tetrahydrocannabinol at 20 ng/mL and 31 ng/mL.
506

Développement d'échantillonneurs passifs de type POCIS pour l'évaluation de la contamination en pesticides des eaux de bassins versants languedociens / Passive samplers development (POCIS) to estimate pesticides contamination of catchment basins in Languedoc Roussillon

Desgranges, Nathalie 23 February 2015 (has links)
Malgré une sensible baisse des ventes depuis quelques années, la France reste le premier utilisateur européen de phytosanitaires. Ceci n’est pas sans conséquences sur l’environnement et les organismes non visés par ces produits. De nombreuses études ont permis d’une part de mieux comprendre les phénomènes de transfert des pesticides dans les compartiments eau-air sols et d’autre part de mettre en évidence leur contamination. Les données concernant l’eau sont plus nombreuses du fait de son statut de réceptacle ultime des pollutions.et des normes établies par les textes réglementaires. La Directive Cadre européenne sur l’Eau (DCE) adoptée en 2000 vise à atteindre le bon état chimique et écologique des eaux d’ici 2015 avec une obligation de résultats. Le bon état chimique dépend du respect des normes de qualité environnementales (NQE) établies notamment pour 24 pesticides. En 2012, 5% des points de mesure en cours d’eau et 19% des points de mesure en eaux souterraines ne respectent pas ces NQE.Le Languedoc Roussillon est depuis de nombreuses années la première région viticole de France et souffre d’une pression phytosanitaire importante. En 2014, un rapport de l’Agence Régionale de Santé (ARS) fait même état de l’utilisation encore récente de pesticides interdits (simazine, terbuthylazine…) depuis le début des années 2000. L’ARS a de plus affirmé que la plupart des cas de non-conformité avérés pouvaient être rattachés à la présence d’activité agricole dans le bassin versant du captage.Remédier à ces contaminations passe par le suivi de la qualité des eaux et la caractérisation de la pollution. Les outils actuels s’avèrent ne pas être toujours représentatifs de cette pollution ;de nouveaux outils sont donc mis au point. L’étude présentée ici porte sur l’utilisation de l’échantillonnage passif de type POCIS (Polar Organic Chemical Integrative Sampler) pour le suivi de la contamination en pesticides de trois bassins versants languedociens : Paulhan,Puissalicon, Roujan.Dans un premier temps, l’étude des limites possibles du dispositif POCIS a été faite pour évaluer son applicabilité dans les conditions d’exposition imposées par le terrain. Le comportement des molécules au sein de l’outil a été étudié pour une meilleure compréhension des phénomènes de diffusion qui s’y produisent. Ces études ont mené à la mise en place de calibrations en laboratoire en conditions contrôlées. [...] La mise en place des dispositifs POCIS sur les trois sites d’études a mis en évidence la prédominance de pesticides utilisés en viticulture et a montré tout l’intérêt de l’outil d’un point de vue qualitatif. La comparaison de l’outil avec l’échantillonnage automatisé montre des disparités entre concentration réelle et concentration estimée via le POCIS. Ce dernier reste à améliorer d’un point de vue quantitatif pour obtenir un échantillonneur fiable et robuste pour ce type de milieu d’exposition. / Despite a noticeable sales decrease since few years, France remains the first european user of phytosanitary products. This is not without consequences on the environment and the untargeted organisms. Several studies allowed on one hand to better understand phenomena of pesticides transfer in water-air and soils compartments and on the other hand to highlight their contamination. Data concerning the water are more numerous cause of its status of ultimate receptacle of pollution and standards established by regulatory texts. The european Water Framework Directive (WFD) adopted in 2000 aims to achieve good chemical and ecological status of water bodies by 2015 with an obligation of results. The good chemical status depends on respect for the Environmental Quality Standards (EQS) established, for instance, for 24 pesticides. In 2012, 5% of river measurement points and 19%of groundwater measurement points do not respect these EQS. For many years, Languedoc Roussillon is the first wine-producing region of France and suffers from a significant pesticide pressure. In 2014, a report from the Regional Health Agency (RHA) has mentioned a relatively recent use of banned pesticides since the early 2000’s like simazin and terbutylazin. Moreover, RHA stated that most of recognized cases of non-compliance could be linked to the presence of agricultural activity in the catchment basin.[...] The establishment of POCIS devices on the three study sites showed the predominance ofpesticides used in viticulture and showed all the interest of the tool on a qualitative point ofview. The comparison of the tool with the automated sampling shows disparities between real concentration and concentration estimated with the POCIS. However, it remains to improvethe tool on a quantitative way to obtain a reliable and robust sampler for this type of exposure medium.
507

Degradação de profenofós em solução aquosa e em ervilhas processadas por feixe de elétrons e a síntese de polímeros impressos para extração seletiva desse pesticida / Degradation of profenofos in aqueous solution and peas by electron beam processed and synthesis of imprinted polymers for selective extraction of this pesticide

Rodrigues, Flavio Thihara 10 April 2015 (has links)
Profenofós é um organofosforado empregado como inseticida e acaricida amplamente utilizado no Brasil para o controle de pragas de cebolas, milho, soja, café, tomate, algodão, feijão, batata e outros. A irradiação é um processo empregado em todo o mundo e recomendada por diversos órgãos de saúde para a conservação de alimentos. A radiação ionizante utiliza raios gama, raios X ou aceleradores de elétrons e tem sido aplicada para eliminar ou reduzir a ação de agentes patogênicos e contribuir para aumentar o tempo de estocagem de vários alimentos. Os objetivos desse trabalho foram: (a) avaliar a degradação de soluções aquosas de profenofós submetidas à radiação ionizante, identificar e quantificar a formação de novos produtos por GC-MS; (b) analisar o efeito de feixe de elétrons em ervilhas inoculadas com soluções aquosas de profenofós; (c) sintetizar Polímeros Molecularmente Impressos (MIP) e Sílica Impressa Molecularmente (MIS), posteriormente, caracterizar os adsorventes em fase sólida e verificar sua seletividade para profenofós. O tratamento com aceleradores de elétrons com dose 31,6 kGy promoveu a formação de um novo produto de degradação e redução de 93,40 % de profenofós em soluções aquosas. Em ervilhas inoculadas com 1 μg de profenofós submetidas à radiação ionizante de 30,4 kGy promoveu uma redução na concentração de profenofós em 57,46 %. Além disso, foram realizadas sínteses de MIP e MIS para a extração em fase sólida de profenofós. Os MIS sintetizados por sol-gel mostraram-se eficazes para o reconhecimento molecular e extração seletiva de profenofós. / Profenofos is an organophosphate widely used in Brazil as insecticide and acaricide in the control of pests in onions, corn, soybeans, coffee, tomato, cotton, beans, potatoes among others. Irradiation is a process used worldwide and recommended by many health agencies for food preservation. Food irradiation preserving process uses accelerated electrons, gamma rays or X-rays. Ionizing radiation treatment is applied to eliminate or to reduce the action of pathogens and to increase the shelf life of some foods. The objective of this study were (a) to evaluate the degradation of aqueous solutions of Profenofos by ionizing radiation, identify and quantify the formation of new products by GC-MS; (b) to analyze the effects of electron beam in peas inoculated with aqueous solutions of Profenofos; (c) to synthesize Molecularly Imprinted Polymer (MIP) and Molecularly Imprinted Silica (MIS), subsequently characterize the adsorbents in solid phase and check its selectivity for profenofos. The treatment with electron accelerators with 31.6 kGy dose promoted the formation of a new by-product and 93.40 % reduction of profenofos in aqueous solutions. In peas inoculated with 1 μg of profenofos by ionizing radiation of 30.4 kGy promoted a reduction of 57.46 % in the concentration of profenofos. Furthermore, the MIP and MIS were performed for solid phase extraction of profenofos. The MIS synthesized by sol-gel proved to be effective for the recognition molecular and selective extraction of profenofos.
508

Influência de diferentes porta-enxertos na composição química dos óleos essenciais e do suco de tangerinas Fremont IAC 543 / The influence of different rootstocks in the essential oils chemical composition and juice volatiles from mandarin Fremont IAC 543

Marques, Stéphano 26 April 2019 (has links)
O objetivo desta pesquisa foi investigar a influência de diferentes porta-enxertos (Limão Cravo, Citrumelo Swingle, Trifoliata e Trifoliata Flying Dragon) na composição química dos óleos essenciais e dos voláteis do suco integral de tangerinas Fremont IAC 543. Os óleos essenciais da casca dos frutos foram obtidos por hidrodestilação, e variaram de 0,36 a 0,47% (v/m), sendo que a tangerina cultivada em porta-enxerto Trifoliata Flying Dragon foi a que apresentou menor rendimento de óleo essencial. A caracterização química dos óleos essenciais foi realizada por cromatografia gasosa acoplada a espectrometria de massas (GC-MS) e a semi-quantificação dos componentes dos óleos essenciais foi realizada por cromatografia gasosa acoplada a detector de ionização em chama (GC-FID). Os compostos majoritários dos óleos essenciais das variedades estudadas foram limoneno, linalol e mirceno, os quais são responsáveis por mais de 95% da área relativa dos componentes dos óleos essenciais. Devido à maior produtividade do porta-enxerto Citrumelo Swingle (18 L/ha), este é o mais indicado para produção de óleo essencial de tangerina Fremont IAC 543. Para a caracterização dos voláteis presentes no suco integral da tangerina Fremont IAC 543 foi realizada a otimização multivaridada da extração dos voláteis do suco por microextração em fase sólida de headspace (HS-SPME). Encontrou-se que a melhor condição para a extração dos voláteis consistiu no uso de fibra de divinilbenzeno/polidimetilsiloxano (DVB/PDMS), temperatura de extração de 43 °C e tempo de 31 min. Os principais compostos voláteis dos sucos integrais estudados foram o limoneno, mirceno, linalol, decanal, α-pineno, havendo bastante variação na composição dos voláteis dos sucos integrais de acordo com o porta-enxerto utilizado. Os espectros de Ressonância Magnética Nuclear mostraram que os sucos das quatro amostras analisadas possuem perfis complexos, porém semelhantes. A tangerina cultivada com porta-enxerto de Limão Cravo apresentou maiores valores de ácido málico e tirosina. A tangerina enxertada com Citrumelo Swingle apresentou maiores quantidades de ácido cítrico e etanol. A variedade plantada sobre o porta-enxerto de Trifoliata apresentou maiores valores de alanina, glicose e sacarose. A amostra cultivada sobre o porta-enxerto de Trifoliara Flying Dragon apresentou menor quantidade de etanol. Através da análise de componentes principais foi possível diferenciar as amostras a partir de seus componentes de óleo essencial e compostos voláteis e não-voláteis do suco integral de cada variedade plantada em diferentes porta-enxertos. / The objective of this research was to investigate the influence of different rootstocks (Clove Lemon, Citrumelo Swingle, Trifoliata and Trifoliata Flying Dragon) on the chemical composition of the essential oils and volatiles of the Fremont IAC 543 mandarin. The essential oils from the fruit peels were obtained by hydrodistillation, and ranged from 0.36 to 0.47% (v/w) and the mandarin cultivated in Trifoliata Flying Dragon rootstock showed the lowest essential oil yield. The chemical characterization of the essential oils was performed by gas chromatography coupled to mass spectrometry (GC-MS) and the semi-quantification of essential oil components was performed by gas chromatography coupled to a flame ionization detector (GC-FID). The major essential oils compounds were limonene, linalool, and myrcene, which were responsible for more than 95% of the essential oil components. Due to the higher productivity of the Citrumelo Swingle rootstock (18 L/ha), this was the most suitable rootstock for the Fremont IAC 543 mandarin essential oil production. Aiming the characterization of the Fremont IAC 543 mandarin juice volatiles compounds, a multivariate optimization of juice volatiles extraction by headspace solid phase microextraction (HS-SPME) was performed. It was found that the best volatile extraction conditions were the use of divinylbenzene/polydimethylsiloxane (DVB/PDMS) fiber, 43 ° C for extraction temperature and 31 min for extraction time. The main volatile compounds of the whole juices studied were limonene, myrcene, linalool, decanal and α-pinene. It possible see a considerable variation in the volatile composition of whole juices according to the rootstock used. Nuclear Magnetic Resonance spectras showed that the juices of the four samples analyzed had complex but similar profiles. Tangerine cultivated with Lemon Cravo rootstock showed higher values of malic acid and tyrosine. Tangerine growth in Citrumelo Swingle showed higher amounts of citric acid and ethanol. The variety planted on the rootstock of Trifoliata showed higher values of alanine, glucose and sucrose. The sample cultivated on the Trifoliara Flying Dragon rootstock showed less ethanol. Through the principal component analysis, it was possible to differentiate the samples using their essential oil components and volatile and non-volatile compounds from the integral juice of each variety planted in different rootstocks.
509

Synthesis of Aldehyde-Functionalized Building Blocks and Their Use for the Cyclization of Peptides : Applications to Angiotensin II

Johannesson, Petra January 2002 (has links)
<p>This study addresses the issue of how to convert peptides into drug-like non- peptides with retained biological activities at peptide receptors. Angiotensin II (Asp-Arg-Val-Tyr-Ile-His-Pro-Phe, Ang II) was used as a model peptide. </p><p>Knowledge of the bioactive conformations of endogenous peptides is invaluable for the conversion of peptides into less peptidic analogues. Effectively constrained cyclic analogues, with retained pharmacological activities, may provide valuable information about the bioactive conformations of the peptide in question. </p><p>This thesis describes the development of synthesis for a number of protected, aldehyde-functionalized building blocks for standard solid phase peptide synthesis, and their use for the preparation of cyclic peptide analogues. The effect of variations in the side-chain lengths of the building blocks, on the outcome of the cyclizations was studied. Incorporation of a building block derived from L-aspartic acid afforded bicyclization towards the C-terininal end of the peptide, while for the corresponding L-glutamic acid derived building block, N-terminal directed bicyclization was achieved. A building block derived from L-2-aminoadipic acid was exploited for monocyclization furnishing <i>cis-</i> and <i>trans-</i> vinyl sulfide bridged peptide analogues. </p><p>The described cyclization methods have been applied to the synthesis of a number of conformationally constrained Ang II analogues, for which the pharmacological properties have been evaluated. Two of the Ang II analogues synthesized displayed high affinities and full agonist activities at the AT<sub>1</sub> angiotensin receptor, and have proven to be useful tools in the search for the bioactive conformation of Ang II.</p>
510

Novel Methods for Synthesis of High Quality Oligonucleotides

Semenyuk, Andrey January 2006 (has links)
<p>The first part of the work describes a procedure of oligonucleotide purification using a reversed-phase cartridge. The developed method employs a very efficient yet mild oligonucleotide detritylation on the cartridge support allowing fast purification of oligonucleotides regardless of their 5´-modification. Thiol- and amino-modified oligonuc-leotides were detritylated and purified with the same high efficiency as non-modified oligonucleotides. The method enables fast, parallel and automated purification of many oligonucleotide probes that was not possible before. In combination with the method of removal of tritylated failure fragments oligonucleotides were produced with purity superior to that of oligonucleotides purified using RP HPLC.</p><p>In the second part of the present study a method of solid-phase RNA synthesis using 2´-tert-butyldithiomethyl (2´-O-DTM) is discussed. The stability of the DTM group during oligonucleotide assembly and deprotection in ammonia, together with its ability for rapid deprotection under mild conditions, allowed the synthesis of RNA with the quality similar to that of synthetic DNA oligonucleotides. The advantage of the 2´-O-DTM group is that it is completely orthogonal to all protecting groups used for the traditional solid-phase DNA synthesis. Therefore, the synthesis can be performed using a standard DNA synthesis procedure – no changes are needed for the product assembly. RNA oligonucleotides synthesized with retained 5´-terminal trityl group can be subjected to a cartridge-based purification using the procedure described in the first part of the study. The phosphoramidite synthesis was optimized for a large scale preparation and gives versatility for introduction of other alkyldithiomethyl groups according to the preference to their certain properties.</p><p>The third part of the thesis describes the synthesis of a dithiomethyl linker and its utility for reversible conjugation of oligonucleotides. A dithiomethyl group, cleavable under mild conditions, was introduced onto 3´-OH of tritylated nucleosides via 3´-O-methylthiomethyl derivatives. The influence of different alkyl substituents on the disulfide bond stability was investigated, and stable analogues were employed in oligosyntheses. Two applications were developed using the present linker: 1) purification of oligonucleotides linked to the solid support; and 2) cartridge-based purification of tritylated oligonucleotides having an additional hydrophobic group on their 3´- terminus.</p>

Page generated in 0.061 seconds