• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 152
  • 58
  • 6
  • 6
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 252
  • 73
  • 54
  • 51
  • 44
  • 36
  • 35
  • 33
  • 32
  • 31
  • 31
  • 29
  • 24
  • 23
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
241

Polydopamine-mediated long-term elution of the direct thrombin inhibitor bivalirudin from TiO₂ nanotubes for improved vascular biocompatibility

Yang, Zhilu, Zhong, Si, Yang, Ying, Maitz, Manfred F., Li, Xiangyang, Tu, Qiufen, Qi, Pengkai, Zhang, Heng, Qiu, Hua, Wan, Jin, Huang, Nan 07 January 2020 (has links)
Thrombosis and restenosis are two major complications associated with current commercial vascular stents. In situ regeneration of a healthy endothelium has been recognized as a promising strategy to address these issues. Numerous strategies have been explored for this goal. However, in most of the cases, they only focused on enhancing endothelial cell growth, ignoring antithrombotic requirements and the competition between smooth muscle cells (SMCs) and endothelial cells (ECs) for their growth. This resulted in non-satisfying clinical results. In this study, we created a multifunctional surface that meets the need of antithrombosis and re-endothelialization. A nanotubular titanium oxide (TiO₂) system has been developed, which elutes the direct thrombin inhibitor, bivalirudin (BVLD); moreover, polydopamine (PDAM) is used to tailor the surface functionality of TiO₂ nanotubes (NTs) for controlling the elution of BVLD. PDAM-functionalized TiO₂ NTs controls the BVLD for more than two months. BVLD eluted from NTs was bioactive and showed a substantial inhibitory effect on thrombin bioactivity, platelet adhesion and activation. In addition, the BVLD-eluting nanotubular TiO₂ system has high selectivity to enhance human umbilical vein endothelial cell (HUVEC) growth, while it inhibits human umbilical artery smooth muscle cell (HUASMC) proliferation. Our design strategy for the BVLD-eluting nanotubular TiO₂ system creates a favorable microenvironment for durable thromboresistance and the promotion of reendothelialization, and thus it is suitable for the long-term treatment of cardiovascular diseases.
242

Determinação do impacto do oversizing da endoprótese sobre a aorta torácica. Estudo experimental em porcos / Impact of stent-graft oversizing on the thoracic aorta: experimental study in a porcine model

Sincos, Igor Rafael 09 November 2012 (has links)
Introdução: A utilização da técnica endovascular para tratar as diversas afecções da aorta têm suplantado as técnicas abertas tradicionais, sendo particularmente promissora no trauma 1. A ruptura traumática da aorta é a segunda causa de morte por acidente de trânsito 2,3; e o reparo endoluminal dessas lesões com endopróteses apresenta menor taxa de mortalidade e paraplegia quando comparada a cirurgia aberta, no entanto os resultados a longo prazo ainda não estão disponíveis2-7. As próteses aprovadas e comercialmente disponíveis, até o momento desse estudo, foram desenhadas para doença aneurismática, com diâmetro muito superior ao diâmetro da aorta de jovens (vítimas de trauma). Esse sobredimensionamento (oversizing) pode levar a alteração mecânica na interação da prótese com a parede aórtica, comprometendo a vascularização e aumento o risco de complicações relacionadas ao implante de endopróteses 8-12. Objetivos: Analisar, a partir de um modelo animal experimental, o efeito biomecânico e histopatológico de quatro níveis diferentes de sobredimensionamento de endopróteses sobre a aorta não aterosclerótica, semelhante às encontradas em pacientes jovens vítimas de trauma. Método: O diâmetro da aorta torácica suína é semelhante ao da aorta de jovens adultos (18-20 mm), desta forma 25 porcos foram randomizados em 5 grupos: 1 controle (sem stent) e 4 grupos de sobredimensionamento (A: 10% -19 %, B: 20% -29%, C: 30% -39%, e D: >40% de sobredimensionamento). Dois tipos de testes biomecânicos foram realizados em todas as aortas 4 semanas após a implantação da endoprótese: \" z\" endoprótese; e o teste de biomecânica propriamente dito dos fragmentos aórticos coletados. Os fragmentos foram, então, submetidos a uma análise histológica e imunohistoquímica. Resultados: Os resultados do teste de destacamento, que avaliou a força necessária para remover o stent da aorta, foram semelhantes nos quatro grupos (A: 42 N, B: 41 N, C: 46 N e D: 46 N, p= 0,881204). O segundo teste foi realizado em três segmentos da aorta. Força máxima, estresse máximo e tensão máxima suportada pela parede da aorta tiveram uma correlação negativa e linear com o oversizing, isto é, quanto maior o oversizing, menor a resistência do fragmento à ruptura. Houve diferenças significativas em todos os quatro grupos, quando comparados com o grupo controle. A deformação máxima e o Strain, que refletem as propriedades elásticas da parede da aorta, foram muito semelhantes em todos os quatro grupos de sobredimensionamento. Mas, uma diminuição significativa da elasticidade foi encontrada quando comparados cada um dos grupos com o grupo controle (p= 0,0000001). A análise histológica e imunohistoquímica demonstrou que a parede da aorta tem uma perda significativa de fibras musculares e ?-actina com o aumento do sobredimensionamento (p= 0,000198 e p= 0,002031, respectivamente). A quantidade de fibra elástica apresentou uma queda significativa independente do sobredimensionamento (p= 0,0000001). Conclusões: Os quatro níveis de sobredimensionamento estudados não demonstraram diferenças significativas no teste de destacamento. Os testes biomecânicos dos fragmentos da aorta mostraram uma diminuição na resistência da parede aórtica proporcional ao aumento do oversizing. A elasticidade da parede aórtica sofre alteração significativa independente do sobredimensionamento utilizado. Os exames histopatológicos e imunohistoquímicos comprovaram o desarranjo na estrutura da parede aórtica com a utilização de endopróteses, resultando na diminuição da quantidade de fibras elásticas e musculares / Introduction: The use of endovascular techniques to treat the various disorders of the aorta has supplanted traditional open techniques, and is particularly promising in trauma1. The traumatic rupture of the aorta is the second leading cause of death by traffic accident2, 3, and repair of these lesions with endoluminal stents has showed lower mortality and paraplegia when compared to open surgery, however the long-term results are not yet available2-7. The endoprosthesis approved and commercially available during this study were designed to aneurysmal disease, with a diameter greater than the diameter of the aorta of young people ( ) \" z \" prosthesis with the aortic wall, affecting the vascularization and raising the risk of complications related to stent-graft implantation8-12. Purpose: Analyze, from an experimental animal model, the biomechanical and histological effects of four different levels of stents-graft oversizing in non-atherosclerotic aortas; such as those aorta found in young individuals who undergo stent-graft repair for traumatic aortic injuries. Methods: The diameter of the porcine thoracic aorta is similar to the aorta of young adults (18-20 mm), so 25 pigs were randomized into 5 groups: 1 control (without stent-graft) and 4 oversizing groups (A: 10%-19%, B: 20%-29%, C: 30%-39%, and D: .40%). Two types of biomechanical tests were performed on all aortas 4 weeks after endoprosthesis deployment: The \"detachment\" of the stent, and the biomechanics test of aortic fragments collected. The fragments were submitted to a histological and an immunohistochemistry analysis. Results: The results of the detachment test, which analyzed the strength necessary to remove the stent-graft from the aorta, were similar in the 4 groups (A: 42 N, B: 41 N, C: 46 N e D: 46 N, p= 0,881204). The second test was performed in 3 aortic segments. Maximum strength, maximum stress, and maximum tension supported by the aortic wall had a negative and linear correlation with oversizing. There were significant differences in all 4 groups when compared with the control group. The maximum deformation and strain, which reflect the elastic properties of the aortic wall, were very similar in all 4 groups. But a significant decrease in elasticity was found when compared each group with the control group (p = 0.0000001). Histological and immunohistochemistry analysis supported that the aortic wall has a signifi-?-actin by increasing the oversize (p = 0.000198 p = 0.002031, respectively). The amount of elastic fiber showed a significant drop regardless of the oversizing (p = 0.0000001). Conclusion: The four levels of oversizing studied did not show significant differences in the detachment test. Biomechanical tests of the fragments of the aorta showed a decrease in resistance of the aortic wall with increase in oversize. The elasticity of the aortic wall undergoes significant change independent of the oversizing used. The histopathological and immunohistochemical examinations confirmed the breakdown in the structure of the aortic wall with the use of stents-graft, resulting in decreased amount of elastic and muscle fibers.
243

Determinação do impacto do oversizing da endoprótese sobre a aorta torácica. Estudo experimental em porcos / Impact of stent-graft oversizing on the thoracic aorta: experimental study in a porcine model

Igor Rafael Sincos 09 November 2012 (has links)
Introdução: A utilização da técnica endovascular para tratar as diversas afecções da aorta têm suplantado as técnicas abertas tradicionais, sendo particularmente promissora no trauma 1. A ruptura traumática da aorta é a segunda causa de morte por acidente de trânsito 2,3; e o reparo endoluminal dessas lesões com endopróteses apresenta menor taxa de mortalidade e paraplegia quando comparada a cirurgia aberta, no entanto os resultados a longo prazo ainda não estão disponíveis2-7. As próteses aprovadas e comercialmente disponíveis, até o momento desse estudo, foram desenhadas para doença aneurismática, com diâmetro muito superior ao diâmetro da aorta de jovens (vítimas de trauma). Esse sobredimensionamento (oversizing) pode levar a alteração mecânica na interação da prótese com a parede aórtica, comprometendo a vascularização e aumento o risco de complicações relacionadas ao implante de endopróteses 8-12. Objetivos: Analisar, a partir de um modelo animal experimental, o efeito biomecânico e histopatológico de quatro níveis diferentes de sobredimensionamento de endopróteses sobre a aorta não aterosclerótica, semelhante às encontradas em pacientes jovens vítimas de trauma. Método: O diâmetro da aorta torácica suína é semelhante ao da aorta de jovens adultos (18-20 mm), desta forma 25 porcos foram randomizados em 5 grupos: 1 controle (sem stent) e 4 grupos de sobredimensionamento (A: 10% -19 %, B: 20% -29%, C: 30% -39%, e D: >40% de sobredimensionamento). Dois tipos de testes biomecânicos foram realizados em todas as aortas 4 semanas após a implantação da endoprótese: \" z\" endoprótese; e o teste de biomecânica propriamente dito dos fragmentos aórticos coletados. Os fragmentos foram, então, submetidos a uma análise histológica e imunohistoquímica. Resultados: Os resultados do teste de destacamento, que avaliou a força necessária para remover o stent da aorta, foram semelhantes nos quatro grupos (A: 42 N, B: 41 N, C: 46 N e D: 46 N, p= 0,881204). O segundo teste foi realizado em três segmentos da aorta. Força máxima, estresse máximo e tensão máxima suportada pela parede da aorta tiveram uma correlação negativa e linear com o oversizing, isto é, quanto maior o oversizing, menor a resistência do fragmento à ruptura. Houve diferenças significativas em todos os quatro grupos, quando comparados com o grupo controle. A deformação máxima e o Strain, que refletem as propriedades elásticas da parede da aorta, foram muito semelhantes em todos os quatro grupos de sobredimensionamento. Mas, uma diminuição significativa da elasticidade foi encontrada quando comparados cada um dos grupos com o grupo controle (p= 0,0000001). A análise histológica e imunohistoquímica demonstrou que a parede da aorta tem uma perda significativa de fibras musculares e ?-actina com o aumento do sobredimensionamento (p= 0,000198 e p= 0,002031, respectivamente). A quantidade de fibra elástica apresentou uma queda significativa independente do sobredimensionamento (p= 0,0000001). Conclusões: Os quatro níveis de sobredimensionamento estudados não demonstraram diferenças significativas no teste de destacamento. Os testes biomecânicos dos fragmentos da aorta mostraram uma diminuição na resistência da parede aórtica proporcional ao aumento do oversizing. A elasticidade da parede aórtica sofre alteração significativa independente do sobredimensionamento utilizado. Os exames histopatológicos e imunohistoquímicos comprovaram o desarranjo na estrutura da parede aórtica com a utilização de endopróteses, resultando na diminuição da quantidade de fibras elásticas e musculares / Introduction: The use of endovascular techniques to treat the various disorders of the aorta has supplanted traditional open techniques, and is particularly promising in trauma1. The traumatic rupture of the aorta is the second leading cause of death by traffic accident2, 3, and repair of these lesions with endoluminal stents has showed lower mortality and paraplegia when compared to open surgery, however the long-term results are not yet available2-7. The endoprosthesis approved and commercially available during this study were designed to aneurysmal disease, with a diameter greater than the diameter of the aorta of young people ( ) \" z \" prosthesis with the aortic wall, affecting the vascularization and raising the risk of complications related to stent-graft implantation8-12. Purpose: Analyze, from an experimental animal model, the biomechanical and histological effects of four different levels of stents-graft oversizing in non-atherosclerotic aortas; such as those aorta found in young individuals who undergo stent-graft repair for traumatic aortic injuries. Methods: The diameter of the porcine thoracic aorta is similar to the aorta of young adults (18-20 mm), so 25 pigs were randomized into 5 groups: 1 control (without stent-graft) and 4 oversizing groups (A: 10%-19%, B: 20%-29%, C: 30%-39%, and D: .40%). Two types of biomechanical tests were performed on all aortas 4 weeks after endoprosthesis deployment: The \"detachment\" of the stent, and the biomechanics test of aortic fragments collected. The fragments were submitted to a histological and an immunohistochemistry analysis. Results: The results of the detachment test, which analyzed the strength necessary to remove the stent-graft from the aorta, were similar in the 4 groups (A: 42 N, B: 41 N, C: 46 N e D: 46 N, p= 0,881204). The second test was performed in 3 aortic segments. Maximum strength, maximum stress, and maximum tension supported by the aortic wall had a negative and linear correlation with oversizing. There were significant differences in all 4 groups when compared with the control group. The maximum deformation and strain, which reflect the elastic properties of the aortic wall, were very similar in all 4 groups. But a significant decrease in elasticity was found when compared each group with the control group (p = 0.0000001). Histological and immunohistochemistry analysis supported that the aortic wall has a signifi-?-actin by increasing the oversize (p = 0.000198 p = 0.002031, respectively). The amount of elastic fiber showed a significant drop regardless of the oversizing (p = 0.0000001). Conclusion: The four levels of oversizing studied did not show significant differences in the detachment test. Biomechanical tests of the fragments of the aorta showed a decrease in resistance of the aortic wall with increase in oversize. The elasticity of the aortic wall undergoes significant change independent of the oversizing used. The histopathological and immunohistochemical examinations confirmed the breakdown in the structure of the aortic wall with the use of stents-graft, resulting in decreased amount of elastic and muscle fibers.
244

"Análise volumétrica da hiperplasia intimal intra-stent em pacientes diabéticos tratados com e sem abciximab" / Volumetric analysis of in-stent intimal hyperplasia in diabetic patients treated with or without abciximab

Chaves, Áurea Jacob 19 July 2004 (has links)
Noventa e seis pacientes com diabetes melito do tipo 2 foram randomizados para receberem ou não abciximab durante o implante eletivo de stent coronário, com o objetivo de determinar se esse inibidor da glicoproteína IIb/IIIa reduz a hiperplasia intimal intra-stent, avaliada pelo ultra-som intracoronário, aos seis meses de evolução. A análise volumétrica mostrou que o abciximab não reduz o volume de obstrução intra-stent nestes pacientes [41,3% (DP21,0%) versus 40,5% (DP18,3%), p=0,853]. / Ninety-six type 2 diabetics were randomly assigned to receive abciximab or no abciximab at the time of elective stent implantation to determine whether this IIb/IIIa glycoprotein inhibitor would reduce in-stent intimal hyperplasia, measured by intravascular ultrasound, at 6-month follow-up. Volumetric analysis showed that abciximab was not associated with a reduction of in-stent volume obstruction in diabetic patients [41.3% (DP21.0%) versus 40.5% (DP18.3%), p=0.853).
245

Custo-efetividade e custo-utilidade dos tratamentos clínico, cirúrgico e percutâneo em portadores de doença coronariana multiarterial estável / Cost-effectiveness and cost-utility of surgery, angioplasty, or medical therapy in patients with multivessel coronary artery disease

Sara Michelly Gonçalves Brandão 05 December 2018 (has links)
Introdução - Os custos para o tratamento da doença arterial coronariana (DAC) são altos em todo o mundo. Foi realizada uma análise post hoc de custo-efetividade de três estratégias terapêuticas para DAC multiarterial. Métodos - De maio de 1995 a maio de 2000, um total de 611 pacientes foram aleatoriamente designados para CRM (n = 203), ICP (n = 205) ou TM (n = 203). Este estudo de análise de custos baseou-se na perspectiva do Sistema Público de Saúde. Os custos iniciais de procedimentos e acompanhamento de medicamentos, exames cardiológicos e hospitalizações por complicações foram calculados após a randomização. Anos de vida e anos de vida ajustados pela qualidade (QALY) foram usados como medidas de eficácia. As razões de custo-efetividade incremental (RCEI) foram obtidas usando métodos de bootstrap não paramétricos com 5.000 replicações. Resultados - Os custos iniciais do procedimento foram menores para o TM. No entanto, os custos acumulados de 5 anos foram menores para a CRM. Em comparação com a linha de base, as 3 opções de tratamento produziram melhorias significativas no QALY. Após 5 anos, a ICP e a CRM tiveram melhores resultados de QALY em comparação com o TM. Os resultados da RCEI favoreceram a CRM e a ICP quando comparadas ao TM, já a ICP em relação à CRM foi mais custo-efetiva em 61% para limiares até 3 PIB per capita por QALY. Por outro lado, a análise de sensibilidade mostrou o TM como a terapia preferida em comparação com a CRM e ICP, na análise considerando custos mais elevados. Conclusão - No seguimento de 5 anos, a ICP e CRM mostraram ser os tratamentos com QALYs cumulativos mais altos entre pacientes com DAC multiarterial quando comparados com TM. Além disso, apesar dos custos iniciais serem mais elevados, a comparação de custo-efetividade após 5 anos de acompanhamento entre os 3 tratamentos mostrou que ambas as intervenções (CRM e ICP) são estratégias custo-efetivas em comparação com a TM / Background. The costs for treating coronary artery disease (CAD) are high worldwide. We performed a post hoc analysis of cost-effectiveness of 3 therapeutic strategies for multivessel CAD. Methods. From May 1995 to May 2000, a total of 611 patients were randomly assigned to CABG (n=203), PCI (n=205), or MT (n=203). This cost analysis study was based on the perspective of the Public Health Care System. Initial procedural and follow-up costs for medications, cardiology examinations, and hospitalizations for complications were calculated after randomization. Life-years and quality-adjusted life years (QALY) were used as effectiveness measures. Incremental cost-effectiveness ratios (ICER) were obtained by using nonparametric bootstrapping methods with 5000 resamples. Results. Initial procedural costs were lower for MT. However, the subsequent 5-year cumulative costs were lower for CABG. Compared with baseline, the 3 treatment options produced significant improvements in QALY. After 5 years, PCI and CABG had better QALY results compared with MT. The ICER results favored CRM and PCI when compared to the TM, since the PCI in relation to the CRM was more costeffective in 61% for the thresholds up to 3 GDP per capita per QALY. On the other hand, sensitivity analysis showed MT as the preferred therapy compared with CABG and PCI, in the analysis considering higher costs. Conclusion. At 5-year follow-up, the 3 treatment options yielded improvements in quality of life, with comparable and acceptable costs. However, despite higher initial costs, the comparison of costeffectiveness after 5 years of follow-up among the 3 treatments showed both interventions (CABG and PCI) to be cost-effective strategies compared with MT
246

Análise dos resultados imediatos e tardios do tratamento percutâneo da coartação da aorta em adolescentes e adultos: comparação entre balões e stents / Analysis of the immediate and late results of percutaneous treatment of coarctation of the aorta in adolescents and adults: comparison between balloons and stents

Pedra, Carlos Augusto Cardoso 05 July 2004 (has links)
Mais informações são necessárias para definir se o tratamento percutâneo da coartação da aorta com stents é superior à angioplastia com cateter-balão. De julho de 2000 a maio de 2003, 21 adolescentes e adultos com coartação da aorta focal e média de idade de 24 anos (DP 11 anos) foram submetidos, consecutivamente, a implante de stents (grupo 1). Os resultados foram comparados com os obtidos em um grupo histórico de 15 pacientes com média de idade de 18 anos (DP 10 anos) (p = 0,103) submetidos a angioplastia (grupo 2) nos últimos 18 anos. Após o procedimento, a redução do gradiente sistólico foi maior (99% [DP 2%] versus 87% [DP 17%]; p = 0,015), o gradiente residual foi menor (0,4 mmHg [DP 1,4 mmHg] versus 5,9 mmHg [DP 7,9 mmHg]; p = 0,019), o ganho no local da coartação foi maior (333% [DP 172%] \"versus\" 190% [DP 104%]; p = 0,007) e o diâmetro da coartação foi maior (16,9 mm [DP 2,9 mm] versus 12,9 mm [DP 3,2 mm]; p < 0,001) no grupo 1. Alterações da parede da aorta, incluindo dissecções, abaulamentos e aneurismas, foram observadas em oito pacientes do grupo 2 (53%) e em um do grupo 1 (7%) (p < 0,001). Não houve complicações maiores. Cateterismo (n = 33) ou ressonância magnética (n = 2) de controle foram realizados em seguimento mediano de um ano para o grupo 1 e um ano e meio para o grupo 2 (p = 0,005). A redução do gradiente sistólico persistiu em ambos os grupos; entretanto, gradientes tardios mais altos foram observados no grupo 2 (mediana de 0 mmHg para o grupo 1 versus 3 mmHg para o grupo 2; p = 0,014). Não houve perdas no diâmetro da coartação no grupo 1 e houve ganho tardio no grupo 2 (16,7 mm [DP 2,9 mm] versus 14,6 mm [DP 3,9 mm]; p = 0,075). No grupo 1, dois pacientes necessitaram de novo implante de stent em decorrência da formação de aneurisma ou fratura da malha do stent. No grupo 2, as anormalidades da parede aórtica não progrediram e um paciente necessitou de redilatação em decorrência da recoartação. A pressão arterial sistêmica foi semelhante em ambos os grupos durante o seguimento (sistólica: 126 mmHg [DP 12 mmHg] no grupo 1 versus 120 mmHg [DP 15 mmHg] no grupo 2; diastólica: 81 mmHg [DP 11 mmHg] no grupo 1 versus 80 mmHg [DP 10 mmHg] no grupo 2; p = 0,149 e p = 0,975, respectivamente). Apesar de os desfechos clínicos terem sido satisfatórios e similares com ambas as técnicas, o uso de stents propiciou resultados mais previsíveis e uniformes para alívio da estenose, minimizando também o risco de desenvolvimento de alterações da parede da aorta. / More information is needed to define whether stenting is superior to balloon angioplasty for coarctation of the aorta. From July/2000 to May/2003, 21 adolescents and adults with discrete coarctation underwent consecutive stent implantation at a mean age of 24 years (SD 11 years) (group 1). The results were compared to those achieved by balloon angioplasty performed in the last 18 years in a historical group of 15 patients at a mean age of 18 years (SD 10 years) (p = 0.103) (group 2). After the procedure, systolic gradient reduction was higher (99% [SD 2%] vs. 87% [SD 17%]; p = 0.015), residual gradients lower (0.4 mmHg [SD 1.4 mmHg] vs. 5.9 mmHg [SD 7.9 mmHg); p = 0.019), gain at the coarctation site higher (333% [SD 172%] vs. 190% [SD 104%]; p = 0.007) and coarctation diameter larger (16.9 mm [SD 2.9 mm] vs.12.9 mm [SD 3.2 mm]; p < 0.001) in group 1. Aortic wall abnormalities, including dissections, bulges and aneurysms, were observed in eight patients in group 2 (53%) and in one in group 1 (7%) (p < 0.001). There was no major complication. Repeat catheterization (n = 33) or magnetic resonance imaging (n = 2) was performed at a median follow-up of 1.0 year for group 1 and 1.5 year for group 2 (p = 0.005). Gradient reduction persisted in both groups, although higher late gradients were observed in group 2 (median of 0 mmHg for group 1 vs. 3 mmHg for group 2; p = 0.014). There was no late loss in the coarctation diameter in group 1 and there was a late gain in group 2 (16.7 mm [SD 2.9 mm] for group 1 vs. 14.6 mm [SD 3.9 mm] for group 2; p = 0.075). Two patients required late stenting due to aneurysm formation or stent fracture in group 1. Aortic wall abnormalities did not progress and one patient required redilation due to recoarctation in group 2. Blood pressure was similar in both groups at follow-up (systolic: 126 mmHg [SD 12 mmHg] in group 1 vs. 120 mmHg [SD 15 mmHg] in group 2; diastolic: 81 mmHg [SD 11 mmHg] in group 1 vs. 80 mmHg [SD 10 mmHg] in group 2; p = 0.149 and p = 0.975, respectively). Although satisfactory and similar clinical outcomes were observed with both techniques, the use of stents yielded more predictable and uniform results for stenosis relief, also minimizing the risk of developing aortic wall abnormalities.
247

Custo-efetividade e custo-utilidade dos tratamentos clínico, cirúrgico e percutâneo em portadores de doença coronariana multiarterial estável / Cost-effectiveness and cost-utility of surgery, angioplasty, or medical therapy in patients with multivessel coronary artery disease

Brandão, Sara Michelly Gonçalves 05 December 2018 (has links)
Introdução - Os custos para o tratamento da doença arterial coronariana (DAC) são altos em todo o mundo. Foi realizada uma análise post hoc de custo-efetividade de três estratégias terapêuticas para DAC multiarterial. Métodos - De maio de 1995 a maio de 2000, um total de 611 pacientes foram aleatoriamente designados para CRM (n = 203), ICP (n = 205) ou TM (n = 203). Este estudo de análise de custos baseou-se na perspectiva do Sistema Público de Saúde. Os custos iniciais de procedimentos e acompanhamento de medicamentos, exames cardiológicos e hospitalizações por complicações foram calculados após a randomização. Anos de vida e anos de vida ajustados pela qualidade (QALY) foram usados como medidas de eficácia. As razões de custo-efetividade incremental (RCEI) foram obtidas usando métodos de bootstrap não paramétricos com 5.000 replicações. Resultados - Os custos iniciais do procedimento foram menores para o TM. No entanto, os custos acumulados de 5 anos foram menores para a CRM. Em comparação com a linha de base, as 3 opções de tratamento produziram melhorias significativas no QALY. Após 5 anos, a ICP e a CRM tiveram melhores resultados de QALY em comparação com o TM. Os resultados da RCEI favoreceram a CRM e a ICP quando comparadas ao TM, já a ICP em relação à CRM foi mais custo-efetiva em 61% para limiares até 3 PIB per capita por QALY. Por outro lado, a análise de sensibilidade mostrou o TM como a terapia preferida em comparação com a CRM e ICP, na análise considerando custos mais elevados. Conclusão - No seguimento de 5 anos, a ICP e CRM mostraram ser os tratamentos com QALYs cumulativos mais altos entre pacientes com DAC multiarterial quando comparados com TM. Além disso, apesar dos custos iniciais serem mais elevados, a comparação de custo-efetividade após 5 anos de acompanhamento entre os 3 tratamentos mostrou que ambas as intervenções (CRM e ICP) são estratégias custo-efetivas em comparação com a TM / Background. The costs for treating coronary artery disease (CAD) are high worldwide. We performed a post hoc analysis of cost-effectiveness of 3 therapeutic strategies for multivessel CAD. Methods. From May 1995 to May 2000, a total of 611 patients were randomly assigned to CABG (n=203), PCI (n=205), or MT (n=203). This cost analysis study was based on the perspective of the Public Health Care System. Initial procedural and follow-up costs for medications, cardiology examinations, and hospitalizations for complications were calculated after randomization. Life-years and quality-adjusted life years (QALY) were used as effectiveness measures. Incremental cost-effectiveness ratios (ICER) were obtained by using nonparametric bootstrapping methods with 5000 resamples. Results. Initial procedural costs were lower for MT. However, the subsequent 5-year cumulative costs were lower for CABG. Compared with baseline, the 3 treatment options produced significant improvements in QALY. After 5 years, PCI and CABG had better QALY results compared with MT. The ICER results favored CRM and PCI when compared to the TM, since the PCI in relation to the CRM was more costeffective in 61% for the thresholds up to 3 GDP per capita per QALY. On the other hand, sensitivity analysis showed MT as the preferred therapy compared with CABG and PCI, in the analysis considering higher costs. Conclusion. At 5-year follow-up, the 3 treatment options yielded improvements in quality of life, with comparable and acceptable costs. However, despite higher initial costs, the comparison of costeffectiveness after 5 years of follow-up among the 3 treatments showed both interventions (CABG and PCI) to be cost-effective strategies compared with MT
248

Optimisation de stents actifs

Bozsak, Franz 03 June 2013 (has links) (PDF)
L'utilisation de stents actifs (DES) a révolutionné le traitement de l'athérosclérose. Le relargage contrôlé de médicaments anti-prolifératifs dans la paroi artérielle (PA) a permis de réduire fortement le taux de resténose intra-stent. Mais le risque de thromboses intra-stents tardives demeure un enjeu majeur des DES en partie lié au retard de cicatrisation de la PA endommagée lors de l'implantation. Cette thèse présente une méthode d'optimisation du design des DES afin d'inhiber la resténose sans affecter la cicatrisation. Pour quantifier la performance des différents designs, un modèle numérique décrivant l'écoulement sanguin et le transport de médicaments dans les artères stentées a été développé. Il prend en compte la structure multi-couches de la PA et les interactions du médicament avec les cellules. Un algorithme d'optimisation est couplé au modèle afin d'identifier les DES optimaux. L'optimisation du temps de relargage ainsi que de la concentration initiale du médicament dans le revêtement du DES ont un effet significatif sur la performance. Lorsque le médicament utilisé est le paclitaxel, les solutions optimales consistent à relarguer le produit à des concentrations nettement inférieures à celles des DES actuels soit pendant quelques heures, soit pendant une durée d'un an. Pour le sirolimus, un relargage lent est nécessaire. Les formes optimales des spires du DES sont toujours allongées mais profilées seulement lorsque le relargage est rapide. Ces résultats permettent d'expliquer en partie les performances des différents DES récents et révèlent un fort potentiel d'amélioration dans la conception des DES par rapport aux dispositifs commerciaux actuels.
249

"Análise volumétrica da hiperplasia intimal intra-stent em pacientes diabéticos tratados com e sem abciximab" / Volumetric analysis of in-stent intimal hyperplasia in diabetic patients treated with or without abciximab

Áurea Jacob Chaves 19 July 2004 (has links)
Noventa e seis pacientes com diabetes melito do tipo 2 foram randomizados para receberem ou não abciximab durante o implante eletivo de stent coronário, com o objetivo de determinar se esse inibidor da glicoproteína IIb/IIIa reduz a hiperplasia intimal intra-stent, avaliada pelo ultra-som intracoronário, aos seis meses de evolução. A análise volumétrica mostrou que o abciximab não reduz o volume de obstrução intra-stent nestes pacientes [41,3% (DP21,0%) versus 40,5% (DP18,3%), p=0,853]. / Ninety-six type 2 diabetics were randomly assigned to receive abciximab or no abciximab at the time of elective stent implantation to determine whether this IIb/IIIa glycoprotein inhibitor would reduce in-stent intimal hyperplasia, measured by intravascular ultrasound, at 6-month follow-up. Volumetric analysis showed that abciximab was not associated with a reduction of in-stent volume obstruction in diabetic patients [41.3% (DP21.0%) versus 40.5% (DP18.3%), p=0.853).
250

Análise dos resultados imediatos e tardios do tratamento percutâneo da coartação da aorta em adolescentes e adultos: comparação entre balões e stents / Analysis of the immediate and late results of percutaneous treatment of coarctation of the aorta in adolescents and adults: comparison between balloons and stents

Carlos Augusto Cardoso Pedra 05 July 2004 (has links)
Mais informações são necessárias para definir se o tratamento percutâneo da coartação da aorta com stents é superior à angioplastia com cateter-balão. De julho de 2000 a maio de 2003, 21 adolescentes e adultos com coartação da aorta focal e média de idade de 24 anos (DP 11 anos) foram submetidos, consecutivamente, a implante de stents (grupo 1). Os resultados foram comparados com os obtidos em um grupo histórico de 15 pacientes com média de idade de 18 anos (DP 10 anos) (p = 0,103) submetidos a angioplastia (grupo 2) nos últimos 18 anos. Após o procedimento, a redução do gradiente sistólico foi maior (99% [DP 2%] versus 87% [DP 17%]; p = 0,015), o gradiente residual foi menor (0,4 mmHg [DP 1,4 mmHg] versus 5,9 mmHg [DP 7,9 mmHg]; p = 0,019), o ganho no local da coartação foi maior (333% [DP 172%] \"versus\" 190% [DP 104%]; p = 0,007) e o diâmetro da coartação foi maior (16,9 mm [DP 2,9 mm] versus 12,9 mm [DP 3,2 mm]; p < 0,001) no grupo 1. Alterações da parede da aorta, incluindo dissecções, abaulamentos e aneurismas, foram observadas em oito pacientes do grupo 2 (53%) e em um do grupo 1 (7%) (p < 0,001). Não houve complicações maiores. Cateterismo (n = 33) ou ressonância magnética (n = 2) de controle foram realizados em seguimento mediano de um ano para o grupo 1 e um ano e meio para o grupo 2 (p = 0,005). A redução do gradiente sistólico persistiu em ambos os grupos; entretanto, gradientes tardios mais altos foram observados no grupo 2 (mediana de 0 mmHg para o grupo 1 versus 3 mmHg para o grupo 2; p = 0,014). Não houve perdas no diâmetro da coartação no grupo 1 e houve ganho tardio no grupo 2 (16,7 mm [DP 2,9 mm] versus 14,6 mm [DP 3,9 mm]; p = 0,075). No grupo 1, dois pacientes necessitaram de novo implante de stent em decorrência da formação de aneurisma ou fratura da malha do stent. No grupo 2, as anormalidades da parede aórtica não progrediram e um paciente necessitou de redilatação em decorrência da recoartação. A pressão arterial sistêmica foi semelhante em ambos os grupos durante o seguimento (sistólica: 126 mmHg [DP 12 mmHg] no grupo 1 versus 120 mmHg [DP 15 mmHg] no grupo 2; diastólica: 81 mmHg [DP 11 mmHg] no grupo 1 versus 80 mmHg [DP 10 mmHg] no grupo 2; p = 0,149 e p = 0,975, respectivamente). Apesar de os desfechos clínicos terem sido satisfatórios e similares com ambas as técnicas, o uso de stents propiciou resultados mais previsíveis e uniformes para alívio da estenose, minimizando também o risco de desenvolvimento de alterações da parede da aorta. / More information is needed to define whether stenting is superior to balloon angioplasty for coarctation of the aorta. From July/2000 to May/2003, 21 adolescents and adults with discrete coarctation underwent consecutive stent implantation at a mean age of 24 years (SD 11 years) (group 1). The results were compared to those achieved by balloon angioplasty performed in the last 18 years in a historical group of 15 patients at a mean age of 18 years (SD 10 years) (p = 0.103) (group 2). After the procedure, systolic gradient reduction was higher (99% [SD 2%] vs. 87% [SD 17%]; p = 0.015), residual gradients lower (0.4 mmHg [SD 1.4 mmHg] vs. 5.9 mmHg [SD 7.9 mmHg); p = 0.019), gain at the coarctation site higher (333% [SD 172%] vs. 190% [SD 104%]; p = 0.007) and coarctation diameter larger (16.9 mm [SD 2.9 mm] vs.12.9 mm [SD 3.2 mm]; p < 0.001) in group 1. Aortic wall abnormalities, including dissections, bulges and aneurysms, were observed in eight patients in group 2 (53%) and in one in group 1 (7%) (p < 0.001). There was no major complication. Repeat catheterization (n = 33) or magnetic resonance imaging (n = 2) was performed at a median follow-up of 1.0 year for group 1 and 1.5 year for group 2 (p = 0.005). Gradient reduction persisted in both groups, although higher late gradients were observed in group 2 (median of 0 mmHg for group 1 vs. 3 mmHg for group 2; p = 0.014). There was no late loss in the coarctation diameter in group 1 and there was a late gain in group 2 (16.7 mm [SD 2.9 mm] for group 1 vs. 14.6 mm [SD 3.9 mm] for group 2; p = 0.075). Two patients required late stenting due to aneurysm formation or stent fracture in group 1. Aortic wall abnormalities did not progress and one patient required redilation due to recoarctation in group 2. Blood pressure was similar in both groups at follow-up (systolic: 126 mmHg [SD 12 mmHg] in group 1 vs. 120 mmHg [SD 15 mmHg] in group 2; diastolic: 81 mmHg [SD 11 mmHg] in group 1 vs. 80 mmHg [SD 10 mmHg] in group 2; p = 0.149 and p = 0.975, respectively). Although satisfactory and similar clinical outcomes were observed with both techniques, the use of stents yielded more predictable and uniform results for stenosis relief, also minimizing the risk of developing aortic wall abnormalities.

Page generated in 0.0509 seconds