• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 7
  • 7
  • 6
  • 6
  • 5
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo experimental dos efeitos de exercícios padronizados, aeróbios e anaeróbios em portadores de diabetes tipo II, mediante avaliações antropométricas, da glicemia e termográficas / Experimental study of the effects of pattern exercises, aerobic and anaerobic, in people with diabetes Mellitus type II, through anthropometric evaluations of glicemic index and termography

Luiz Eduardo Genovez Damiano 23 February 2007 (has links)
O diabetes Mellitus tipo II tem sido preocupação corrente nos dias atuais, pois, independente dos fatores desencadeados desta doença e de até certo ponto, algumas controvérsias sobre os mesmos, quaisquer investigações que possam contribuir para a melhoria de vida dos portadores do diabetes Mellitus tipo II, são altamente necessários. Destaque-se também que o levantamento estatístico e social da incidência dessa doença, tem demonstrado recentemente, que ocorrências tem incidido em indivíduos cada vez mais jovens contrariando a idéia de eventuais relações com idade avançada dos portadores. Durante os anos 90 estimava-se a existência de aproximadamente 175 a 200 milhões de diabéticos tipo II, em todo o mundo, por prospecção estima-se que em 2025, serão 300 milhões, os portadores da doença, sendo que 90 a 95% deles corresponderão ao tipo II. Esses fatos conduzem a presente pesquisa visto que, o exercício associado a medicamentos tem sido os elementos responsáveis pela melhoria de vida dos portadores de diabetes tipo II. Em vista disso foi proposto o estudo de 2 tipos de exercícios padronizados e avaliados mediante dosagem de glicose e teletermografia periférica. O nível glicêmico avaliado antes e após os 2 tipos de exercícios, (aeróbio e anaeróbio) demonstrou-se mais sensível aos exercícios anaeróbios propostos nesta investigação. Exercícios aeróbios (GDEA) - média da glicemia inicial 127,40 mg/dl - média da glicemia final 97,92 mg/dl - desvio padrão glicemia inicial 97,72 mg/dl, glicemia final 69,98 mg/dl. Exercícios anaeróbios (GDEAn) - média da glicemia inicial 132,62 mg/dl - média da glicemia final 91,54 mg/dl - desvio padrão glicemia inicial 90,84 mg/dl, glicemia final 61,11 mg/dl. A teletermografia periférica avaliada mediante a circulação do tegumento das plantas dos pés demonstrou-se igualmente favorável aos portadores dos diabetes tipo II submetidos aos exercícios anaeróbios. Exercícios aeróbios (GDEA) média da temperatura 28,09 graus Celsius - desvio padrão 1,14 graus Celsius.Exercícios anaeróbios (GDEAn) média da temperatura 29,67 graus Celsius - desvio padrão 1,13 graus Celsius. Procurou-se eventuais explicações para os resultados aqui obtidos, em vista dos quais os exercícios a serem praticados em portadores de diabetes Mellitus tipo II devem ser revistos. / Diabetes Mellitus type II investigations about quality of life improvement have been a concern nowadays, although there is some controversy about the cause of this disease. The incidence of this disease has been on younger people, what shows no direct relation with aging. During 90 decade it was estimated to exist 175 to 200 millions of people with diabetes type II around the world, it is estimated that in 2025 there will be 300 millions of diabetic people and 90 to 95% of these with the type II one. Those facts conduct the present research. Exercise associated to medicaments has improved the quality of life in people with diabetes type II. The present study investigated two different exercises and evaluated both with glucose dosage and periferical teletermography. Glicemic level was evaluated before and after both type of exercise (aerobic and anaerobic), and it was more sensitive to anaerobic exercises proposed. Aerobic exercises (GDEA) - mean initial glicemic index 127,40 mg/dl - mean final glicemic index 97,92 mg/dl - initial glicemic standard deviation 97,72 mg/dl - final glicemic standard deviation - 69,98 mg/dl. Anaerobic exercises (GDEAn) - mean initial glicemic index 132,62 mg/dl - mean final glicemic index 91,54 mg/dl - initial glicemic standard deviation 90,84 mg/dl - final glicemic standard deviation - 61,11 mg/dl. Peripherical teletermography evaluated trough feet plantar circulation demonstrated to be equally suitable to people with diabetes type II submitted to GDEA, mean temperature 28,09 °C - standard deviation 1,14°C, and to GDAn, mean temperature 29,67°C - standard deviation 1,13°C. Explanation was searched for presented results, those results demonstrated that exercise practicing must be reviewed if practiced by people with diabetes mellitus type II.
2

Efeitos dos exercícios de aquecimento e alongamento na flexibilidade de sujeitos idosos

Ferreira, José Jamacy de Almeida 14 March 2008 (has links)
Made available in DSpace on 2016-06-02T20:18:08Z (GMT). No. of bitstreams: 1 1702.pdf: 882223 bytes, checksum: ee9bdf9e2683cdafe91338db411cbade (MD5) Previous issue date: 2008-03-14 / Financiadora de Estudos e Projetos / Este estudo teve o propósito de avaliar as alterações termográficas associadas ao exercício localizado em sujeitos idosos e jovens. Um protocolo de exercícios utilizando carga de 1 Kg foi aplicado durante 3 minutos aos flexores do joelho de 14 sujeitos idosos (67±5 anos) e 15 jovens (23±2 anos) saudáveis. A temperatura do membro exercitado e contralateral foi medida por meio de termografia por infravermelho em condições pré-exercício, imediatamente pósexercício e durante o período de 10 minutos pós-exercício. Foi observada uma diferença (p<0,01) na temperatura pré-exercício entre os sujeitos idosos e jovens. Embora não tenha sido observada diferença entre a temperatura pré-exercício e imediatamente pós-exercício no membro exercitado, o perfil termográfico mostrou uma concentração de calor nas áreas exercitadas, para ambos os grupos. Apenas para os sujeitos jovens houve diminuição da temperatura do membro exercitado (p<0,05) aos 10 min pós-exercício (de 30,7±1,7 para 30,3±1,5 º C). Em contraste, houve uma redução da temperatura pós-exercício no membro contralateral (p<0,01), para ambos os grupos. Estes resultados apontam para novas evidências de que sujeitos jovens e idosos apresentam capacidade similar de produção de calor; entretanto, os sujeitos idosos apresentaram uma menor temperatura de repouso e uma dissipação de calor mais lenta. Este trabalho contribui para melhorar o entendimento sobre as alterações de temperatura em sujeitos idosos e pode apresentar implicações na prática esportiva e para os programas de reabilitação
3

Avaliação sazonal da qualidade seminal a fresco, refrigerado e pós-descongelação de touros Nelore / Sazonal evaluation of seminal quality to fresh, cooled and frozen-thawed of Nelore bulls

Francisquini , Camila Dutra de Souza 10 October 2018 (has links)
Submitted by Michele Mologni (mologni@unoeste.br) on 2018-11-22T11:15:18Z No. of bitstreams: 1 Camila Dutra de Souza Francisquini.pdf: 2946141 bytes, checksum: d4a8301da20ac5338becde2b5af3e95b (MD5) / Made available in DSpace on 2018-11-22T11:15:18Z (GMT). No. of bitstreams: 1 Camila Dutra de Souza Francisquini.pdf: 2946141 bytes, checksum: d4a8301da20ac5338becde2b5af3e95b (MD5) Previous issue date: 2018-10-10 / In regions of tropical climate, mating occurs during warmer months, bulls are subject to environmental variations that interfere with their fertility and reproductive efficacy of the herd. The use of some biotechnologies contributes to the efficiency of the production system and to evaluate the fertilization potential of a semen sample, be it fresh, chilled or frozen. A combination of several analyzes and seminal assay methods offers greater accuracy to define a complex functionality. For Chapter 1, the objectives of the study were: (1) to evaluate the effect of the seasons on the surface temperature of the scrotum and ocular globe, the semen quality and plasma concentration of testosterone from Nellore bulls raised extensively, (2) to verify the plasma protein composition (3) investigate the relationships of these proteins with seminal parameters, surface temperatures of the scrotum and THI. Nellore bulls (n = 20) were evaluated with two data collections with a 30-day interval within each season of the year. Infrared thermography (FLIR E40®) with image analysis (FLIR tools software) for spermatic cord (SCT), proximal pole of the testis (PPT), distal pole of the testis (DPT), tail of the epididymis (TeT) and scrotal temperature gradient (TG), and semen collected and analyzed for quantitative and qualitative characteristics. Blood samples were collected by venipuncture of the jugular to obtain the plasma concentration of testosterone by radioimmunoassay (RIA). The seminal plasma proteins were identified by electrophoresis on SDS-PAGE. The temperature-humidity index (THI) calculated per season. The TG was higher (P <0.05) in autumn (5ºC) and winter (4.4ºC) compared to spring (3.4ºC) and summer (3.7ºC). The THI of spring (73.5) and summer (72) differed (P <0.05) from autumn (64.5) and winter (59.6) and there were correlations (P <0.01) with SCT (0.54), TeT (0.74), PPT (0.71), DPT (0.72) and TG (-0.35). Similarly, MOT (61.5%) and VIG (2.7) in spring were lower in relation to autumn and winter (P <0.05). The plasma concentration of testosterone was higher (P <0.05) in the autumn, in relation to the other seasons of the year. Seminal plasma proteins of 20, 55 and 66KDa contributed positively to seminal quality. The concentration of the protein with 50KDa was high in all seasons, being considered indispensable for the fertility of the bulls. In the spring and summer seasons, in which the THI exceeded the value of 72, there was a decrease in progressive motility and spermatic vigor. The summer and fall, the seasons that presented greater percentages of major and total sperm defects. Ocular globe and scrotal surface temperatures increased in spring and summer and the thermal gradient and testosterone plasma concentration decreased in the same seasons, concluding that the thermal stress with THI above 72 in the spring and summer seasons was sufficient for negatively affect the reproduction of Nelore bulls raised in pasture in the tropics. The chapter 2, the objectives of the study were: (1) assess the quality of refrigerated beef semen transported by 3 hours, passive systems of transport of semen BotuBOX® and BotuFLEX®, diluted in TRIS and BotuBOV®; and (2) evaluate the spermatic kinetics, oxidative stress, mitochondrial potential and cell membrane integrity and acrossomal bovine semen after thawing, diluted in TRIS and BotuBOV® and transported in passive systems semen transport BotuBOX® and BotuFLEX®. The six bulls semen of Nellore breed (Bos taurus indicus), cooled and frozen in 2 extenders TRIS and BotuBOV® and transported in 2 cooling systems BotuBOX® and BotuFLEX®. In a semen sample refrigerated was made a subjective analysis of motility (MOT) and sperm vigor (VIG) and in the sample frozen-thawed, computer-assisted sperm analysis (CASA) and flow cytometry, evaluation of integrity of plasma membrane and acrossomal (IPAM), production of superoxide (O2-) and integrity of cells (IC). On after cooled analysis, the MOT of semen in the BotuBOV® and BotuFLEX® (69.4%) and TRIS and BotuFLEX® (62.9%), were higher (P < 0.05) when compared to the TRIS and BotuBOX®. The largest (P < 0.05) MOT (45.9%) observed in subjective analysis, TM (47.3%) and PM (37%) in the CASA, IPAM (29%), IC (19.8%) and lower production of the O2- (82%) found in the samples frozen-thawed diluted in BotuBOV® extender and transported in the BotuFLEX® system. We conclude that the diluted semen in the BotuBOV® and transported on BotuBOX® or BotuFLEX®, and diluted TRIS extender and transported on BotuFLEX® maintained the viability for using the cooled semen, as well as employment for freezing. The association between the BotuBOV® diluent and refrigerated transport of semen BotuFLEX® presented best effect on the frozen semen in regard to kinetics parameters, integrity of plasma and acrossomal membranes and oxidative stress reduction. / Em regiões de clima tropical, o acasalamento ocorre durante os meses mais quentes, os touros estão sujeitos às variações ambientais que interferem com a sua fertilidade e eficácia reprodutiva do rebanho. A utilização de algumas biotecnologias colabora para a eficiência do sistema de produção e avaliar o potencial de fertilização de uma amostra de sêmen, seja ela fresca, refrigerada ou congelada e Uma combinação de várias análises e métodos de avalição seminal oferece maior acurácia para definir uma complexa funcionalidade. Para o capítulo 1, os objetivos do estudo foram (1) avaliar o efeito das estações do ano na temperatura da superfície do escroto e do globo ocular, na qualidade do sêmen e concentração plasmática de testosterona de touros Nelore criados extensivamente, (2) verificar a composição proteica do plasma seminal em cada estação do ano e as proteínas com maior frequência e (3) investigar as relações dessas proteínas com parâmetros seminais, temperaturas da superfície do escroto e ITU. Touros Nelore (n=20) foram avaliados com duas coletas de dados com intervalo de 30 dias dentro de cada estação do ano, sendo realizados: termografia infravermelha (FLIR E40®) com análise de imagens (software FLIR tools) para cordão espermático (TCE), polo proximal do testículo (PPT), polo distal do testículo (PDT, cauda do epidídimo (TCEp) e gradiente de temperatura escrotal (GT). O sêmen foi coletado e analisado quanto às características quantitativas e qualitativas. Amostras de sangue foram coletadas por venopunção da jugular para obter a concentração plasmática de testosterona por radioimunoensaio (RIA). As proteínas do plasma seminal foram identificadas por eletroforese em SDS-PAGE. O índice de temperatura-umidade (ITU) por estação do ano. O GT foi maior (P<0.05) no outono (5ºC) e inverno (4.4ºC) comparado a primavera (3.4ºC) e verão (3.7ºC). O ITU da primavera (73.5) e verão (72) diferiram (P<0,05) do outono (64.5) e inverno (59.6) e houveram correlações (P<0,01) com TCE (0.54), TCEp (0.74), PPT (0.71), PDT (0.72) e GT (-0.35). Assim como, motilidade espermática (61.5%) e vigor (2.7) na primavera foram inferiores, em relação ao outono e inverno (P<0.05). A concentração plasmática de testosterona foi superior (P<0,05) no outono, em relação às demais estações do ano. As bandas proteicas do plasma seminal de 20, 55 e 66KDa contribuíram de forma positiva para a qualidade seminal. A concentração da banda com 50KDa foi elevada em todas as estações, sendo considerada indispensável para a fertilidade dos touros. Nas estações primavera e verão, nas quais o ITU excedeu o valor de 72, observou-se decréscimo na motilidade progressiva e vigor espermático. O verão e outono, as estações que apresentaram maiores porcentagens de defeitos espermáticos maiores e totais. As temperaturas do globo ocular e da superfície do escroto aumentaram na primavera e verão e o gradiente térmico e a concentração plasmática de testosterona diminuiu nas mesmas estações, concluindo que o estresse térmico com ITU acima de 72, nas estações primavera e verão, foi suficiente para afetar negativamente a reprodução de touros Nelore criados a pasto nos trópicos. Para o capítulo 2, Os objetivos do estudo foram: (1) avaliar a qualidade do sêmen bovino refrigerado transportado por 3 horas, nos sistemas passivos de transporte de sêmen BotuBOX® e BotuFLEX®, diluídos nos meios TRIS e BotuBOV®; e (2) avaliar a cinética espermática, estresse oxidativo, potencial mitocondrial e integridade de membrana plasmática e acrossomal do sêmen bovino pós-descongelação, diluídos nos meios TRIS e BotuBOV® e transportados nos sistemas passivos de transporte de sêmen BotuBOX® e BotuFLEX®. O sêmen de seis touros da raça Nelore (Bos taurus indicus), refrigeradas e congeladas em 2 meios diluentes TRIS e BotuBOV® e transportados em 2 sistemas de refrigeração BotuBOX® e BotuFLEX®. Em uma amostra de sêmen refrigerado foi realizada a análise subjetiva de motilidade (MOT) e vigor (VIG) e na amostra pós-descongelação, realizada a análise computadorizada da motilidade espermática (CASA) e por citometria de fluxo, avaliação de integridade de membrana plasmática e acrossomal (MPA), produção de superóxido (O2) e células íntegras (CI). Na análise pós-refrigeração, a MOT do sêmen na associação BotuBOV® e BotuFLEX® (69.4%) e TRIS e BotuFLEX® (62.9%), foram maiores (P<0.05) quando comparado à TRIS e BotuBOX®. A maior (P<0.05) MOT (45.9%) observada na análise subjetiva, MT (47.3%) e MP (37%) no CASA, MPAI (29%), CI (19.8%) e menor produção de O2- (82%) encontrados nas amostras pós-descongelação diluídas em meio BotuBOV® e transportados no sistema BotuFLEX®. Concluímos que o sêmen diluído no meio BotuBOV® e transportado na BotuBOX® ou BotuFLEX®, e diluído em meio TRIS e transportado na BotuFLEX® mantiveram a viabilidade seminal para uso do sêmen refrigerado, bem como o emprego para a congelação. A associação entre o meio diluente BotuBOV® e o sistema de transporte refrigerado de sêmen BotuFLEX® apresentou melhor efeito sobre o sêmen congelado em relação aos parâmetros de cinética espermática, integridade de membrana plasmática e acrossomal e redução do estresse oxidativo.
4

Estudo experimental dos efeitos de exercícios padronizados, aeróbios e anaeróbios em portadores de diabetes tipo II, mediante avaliações antropométricas, da glicemia e termográficas / Experimental study of the effects of pattern exercises, aerobic and anaerobic, in people with diabetes Mellitus type II, through anthropometric evaluations of glicemic index and termography

Damiano, Luiz Eduardo Genovez 23 February 2007 (has links)
O diabetes Mellitus tipo II tem sido preocupação corrente nos dias atuais, pois, independente dos fatores desencadeados desta doença e de até certo ponto, algumas controvérsias sobre os mesmos, quaisquer investigações que possam contribuir para a melhoria de vida dos portadores do diabetes Mellitus tipo II, são altamente necessários. Destaque-se também que o levantamento estatístico e social da incidência dessa doença, tem demonstrado recentemente, que ocorrências tem incidido em indivíduos cada vez mais jovens contrariando a idéia de eventuais relações com idade avançada dos portadores. Durante os anos 90 estimava-se a existência de aproximadamente 175 a 200 milhões de diabéticos tipo II, em todo o mundo, por prospecção estima-se que em 2025, serão 300 milhões, os portadores da doença, sendo que 90 a 95% deles corresponderão ao tipo II. Esses fatos conduzem a presente pesquisa visto que, o exercício associado a medicamentos tem sido os elementos responsáveis pela melhoria de vida dos portadores de diabetes tipo II. Em vista disso foi proposto o estudo de 2 tipos de exercícios padronizados e avaliados mediante dosagem de glicose e teletermografia periférica. O nível glicêmico avaliado antes e após os 2 tipos de exercícios, (aeróbio e anaeróbio) demonstrou-se mais sensível aos exercícios anaeróbios propostos nesta investigação. Exercícios aeróbios (GDEA) - média da glicemia inicial 127,40 mg/dl - média da glicemia final 97,92 mg/dl - desvio padrão glicemia inicial 97,72 mg/dl, glicemia final 69,98 mg/dl. Exercícios anaeróbios (GDEAn) - média da glicemia inicial 132,62 mg/dl - média da glicemia final 91,54 mg/dl - desvio padrão glicemia inicial 90,84 mg/dl, glicemia final 61,11 mg/dl. A teletermografia periférica avaliada mediante a circulação do tegumento das plantas dos pés demonstrou-se igualmente favorável aos portadores dos diabetes tipo II submetidos aos exercícios anaeróbios. Exercícios aeróbios (GDEA) média da temperatura 28,09 graus Celsius - desvio padrão 1,14 graus Celsius.Exercícios anaeróbios (GDEAn) média da temperatura 29,67 graus Celsius - desvio padrão 1,13 graus Celsius. Procurou-se eventuais explicações para os resultados aqui obtidos, em vista dos quais os exercícios a serem praticados em portadores de diabetes Mellitus tipo II devem ser revistos. / Diabetes Mellitus type II investigations about quality of life improvement have been a concern nowadays, although there is some controversy about the cause of this disease. The incidence of this disease has been on younger people, what shows no direct relation with aging. During 90 decade it was estimated to exist 175 to 200 millions of people with diabetes type II around the world, it is estimated that in 2025 there will be 300 millions of diabetic people and 90 to 95% of these with the type II one. Those facts conduct the present research. Exercise associated to medicaments has improved the quality of life in people with diabetes type II. The present study investigated two different exercises and evaluated both with glucose dosage and periferical teletermography. Glicemic level was evaluated before and after both type of exercise (aerobic and anaerobic), and it was more sensitive to anaerobic exercises proposed. Aerobic exercises (GDEA) - mean initial glicemic index 127,40 mg/dl - mean final glicemic index 97,92 mg/dl - initial glicemic standard deviation 97,72 mg/dl - final glicemic standard deviation - 69,98 mg/dl. Anaerobic exercises (GDEAn) - mean initial glicemic index 132,62 mg/dl - mean final glicemic index 91,54 mg/dl - initial glicemic standard deviation 90,84 mg/dl - final glicemic standard deviation - 61,11 mg/dl. Peripherical teletermography evaluated trough feet plantar circulation demonstrated to be equally suitable to people with diabetes type II submitted to GDEA, mean temperature 28,09 °C - standard deviation 1,14°C, and to GDAn, mean temperature 29,67°C - standard deviation 1,13°C. Explanation was searched for presented results, those results demonstrated that exercise practicing must be reviewed if practiced by people with diabetes mellitus type II.
5

Tipologia e conforto térmico em galpões avícolas no Estado de Pernambuco e sua influência no desempenho de frangos de corte / Typology and thermal comfort in the state of poultry sheds and its influence on Pernambuco performance of broiler

SILVA, Tatiana Patrícia Nascimento da 25 February 2013 (has links)
Submitted by (lucia.rodrigues@ufrpe.br) on 2016-10-14T11:39:21Z No. of bitstreams: 1 Tatiana Patricia Nascimento da Silva.pdf: 1324693 bytes, checksum: 31662474b4f5103f7a070cf7f5439bb7 (MD5) / Made available in DSpace on 2016-10-14T11:39:21Z (GMT). No. of bitstreams: 1 Tatiana Patricia Nascimento da Silva.pdf: 1324693 bytes, checksum: 31662474b4f5103f7a070cf7f5439bb7 (MD5) Previous issue date: 2013-02-25 / This research was conducted with the objective of analyzing quantitative and qualitative aspects of the poultry houses in terms of thermal efficiency and typology of built environments, with emphasis on productive performance. The first step was a survey of the main typological characteristics of the region where it was evaluated 68 sheds on 27 farms in the period May 2011 to April 2012, which allowed the removal of the constructive features of the aviaries in mesoregion of Pernambuco. For the second stage we selected five sheds with different typological characteristics, to determine the thermal efficiency of the system-poultry shed by means of thermal comfort indices (radiant heat load index, globe temperature and humidity and specific enthalpy) and the balance energy (sensible and latent exchanges) based on the performance of broilers. As a result of the first stage, the constructive characteristics were most evident width of 10-12 m (56%), length of 100-120 m (59%), with a slight separation between warehouses (<30 m) below the ceiling recommended (<3 m), eaves between 1 and 1.25 m (40%) low walls and high (> 0.2 m). As for natural cooling, most installations presented coverage natural lawn type (56%), no lining (96%) and louver (100%), cover with ceramic tile (93%), reflective paint on the roof (97%) and oriented east / west (89.7%). For artificial cooling, the primary heating source is wood hoods (71%), positive pressure ventilation (68%), fogging at high pressure (57%). As for the equipment presented to most feeders (54%) and drinkers (65%) commuting, axial fans (100%), the bed was used by most rice straw (56%) and yellow curtain (65%). In the second phase of this work, the thermal comfort indices showed no significant difference between the sheds (P <0.05). Environmental variables showed variations during the day, and the hours of 09 am to 15:00, showed mean values above the thermal comfort zone. As the energy balance, trade sensitive significant difference among the five sheds, as the times the effect was significant (P <0.05). The sensitive exchanges showed variation between the sheds. The data showed an increase in trade latent from the fourth week, but these values were lower than is thermal stress conditions, except for 3 who shed the seventh week exceeded trade exchanges latent sensitive. With respect to production performance, we note that there was no significant difference between 1 and 4 to shed the weight gain, mortality, feed intake and feed conversion. Including this last variable Shed 3. For other sheds the difference was significant at the 5% level of probability. Overall, it can be observed that the values found for the production indices remained below the tracks taken as optimal for cutting poultry industry. / Esta pesquisa foi conduzida com o objetivo de analisar aspectos quantitativos e qualitativos das instalações avícolas, em termos de eficiência térmica e tipologia dos ambientes construídos, com ênfase no desempenho produtivo das aves. Na primeira etapa foi realizado um levantamento das principais características tipológicas da região onde foi avaliados 68 galpões, em 27 granjas, no período de maio de 2011 a abril de 2012, o que permitiu o levantamento das características construtivas dos aviários na Mesorregião do Agreste pernambucano. Para a segunda etapa foram selecionados cinco galpões com características tipológicas distintas, para determinação da eficiência térmica no sistema ave-galpão, por meio dos índices de conforto térmico (carga térmica radiante, índice de temperatura de globo e umidade e entalpia específica) e do balanço de energia (trocas sensíveis e latentes) com base no desempenho de frangos de corte. Como resultado da primeira etapa, as características construtivas mais evidentes foram largura de 10-12 m (56%), comprimento de 100-120 m (59%), com pequeno afastamento entre galpões (< 30 m), pé-direito abaixo do recomendado (<3 m), beirais entre 1 e 1,25 m (40%) e muretas altas (> 0,2 m). Quanto à climatização natural, a maioria das instalações apresentou cobertura natural tipo gramado (56%), ausência forro (96%) e lanternim (100%), cobertura com telha cerâmica (93%), pintura reflexiva no telhado (97%) e orientação leste/oeste (89,7%). Para a climatização artificial, a principal fonte de aquecimento foi campânulas a lenha (71%), ventilação a pressão positiva (68%), nebulização a alta pressão (57%). Quanto aos equipamentos à maioria apresentaram comedouros (54%) e bebedouro (65%) pendulares, ventiladores axiais (100%), a cama utilizada pela maioria foi palha de arroz (56%) e cortina amarela (65%). Na segunda etapa do desse trabalho, os índices de conforto térmicos não apresentaram diferença significativa entre os galpões (P<0,05). As variáveis ambientais apresentaram variações ao longo do dia, sendo que os horários das 09 às 15:00, mostraram valores médios acima da zona de conforto térmico. Quanto o balanço de energia, as trocas sensíveis apresentaram diferença significativa entre os cinco galpões, quanto aos horários o efeito foi significativo (P<0,05). As trocas sensíveis apresentaram variação entre os galpões. Os dados mostraram que houve aumento das trocas latentes a partir da quarta semana, porém esses valores ficaram abaixo do que representa condições de estresse térmico, com exceção do galpão 3 que na sétima semana as trocas latentes ultrapassaram as trocas sensíveis. Com relação ao desempenho produtivo, nota-se que não houve diferença significativa entre o galpão 1 e 4 para as variáveis ganho de peso, mortalidade, consumo de ração e conversão alimentar. Incluindo nessa última variável o galpão 3. Para os demais galpões a diferença foi significativa ao nível de 5% de probabilidade. No geral, pode-se observar que os valores encontrados para os índices produtivos se mantiveram abaixo das faixas tidas como ideais para a indústria de aves de corte.
6

Avaliação da estabilidade temporal da umidade do solo em uma bacia experimental no semiárido pernambucano e uso da termografia para estimativa da permeabilidade do solo.

SILVA JÚNIOR, Valdemir de Paula e 03 February 2015 (has links)
Submitted by (lucia.rodrigues@ufrpe.br) on 2016-10-14T14:40:26Z No. of bitstreams: 1 Valdemir de Paula e Silva Junior.pdf: 1674024 bytes, checksum: fa219e683d9e8d4feb594943a85825eb (MD5) / Made available in DSpace on 2016-10-14T14:40:26Z (GMT). No. of bitstreams: 1 Valdemir de Paula e Silva Junior.pdf: 1674024 bytes, checksum: fa219e683d9e8d4feb594943a85825eb (MD5) Previous issue date: 2015-02-03 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Soil water content has an important role for agricultural practices, influencing water movement and storage within the soil. In semiarid regions, knowledge concerning soil water content holds great relevance, mainly due to precipitation’s high spatial-temporal variability and high evapotranspiration indices, bringing about soil water deficit. The aim of this study was to evaluate spatial and temporal stability of soil water content under different cover crop conditions and soil types, in order to identify a representative point for soil water content readings. Additionally, it was evaluated the use of infrared thermography as a tool to estimate non-saturated hydraulic conductivity at a representative watershed, located in Pesqueira, in the semiarid region of Pernambuco. A grid of points for soil water content measurement was monitored, using a capacitive probe. In the first chapter, the soil water content data was evaluated on a hillslope with six measuring points, under natural vegetation and pasture with the same type of soil (Red Yellow Ultisol). According to temporal stability concept, the technique for relative mean differences and standard deviations was applied in order to investigate the point, which is capable of representing the mean temporal behavior of the other measuring points, and the correlation among soil water content points. In the second chapter, temporal variation patterns were analyzed for seventeen soil water content points distributed along the watershed, under two different soil types: Yellow Ulitsol and Regolithic Entisol, and two cover crop conditions, being used the mean relative differences technique and correlation among points in order to validate if the stable point would be the same found for the hill experiment. In the third chapter, published in the Quantitative Infrared Thermography Journal, v.11, 2:2014, p.161-169, infrared thermography technique was used to estimate soil hydraulic conductivity. The study was performed in a laboratory of the Coimbra University, using a slope soil channel and three types of soil and a thermographic video camera to record the images. Estimated hydraulic conductivity data with the infrared thermography technique were correlated to the values obtained with the aid of a constant-head permeameter, by statistical indices and regression analysis. For the fourth chapter, the thermography technique was used under field condition to estimate non-saturated hydraulic conductivity, in the Mimoso watershed, for two soil types: Yellow Ultisol and Fluvic Entisol. Four different hydraulic heads were applied to soil surface, with three replications and seven tests for each soil type under different initial conditions of soil temperature and thermal records using a thermographic camera. Thermal records were correlated to non-saturated soil hydraulic conductivity, which presented high correlations. Water content dynamics technique allowed the identification of a point of stability in the watershed. Thermal records enabled the distinction between the studied soil types, when subjected to different hydraulic heads, being related with the respective non-saturated hydraulic conductivities. It was verified that the thermography is an innovative technique capable of estimating non-saturated hydraulic conductivity, enabling the mapping of soil surface conditions. / A umidade do solo tem grande importância para as atividades agrícolas, influenciando o movimento da água no solo e no seu armazenamento. Em regiões de clima semiárido, o conhecimento da umidade no solo tem grande relevância, principalmente por causa da grande variabilidade espacial e temporal da precipitação e dos altos índices de evapotranspiração, provocando déficit de umidade no solo. O objetivo desse estudo foi avaliar a estabilidade temporal e espacial da umidade do solo sob diferentes condições de cobertura vegetal e tipos de solo a fim de identificar um ponto que representativo para leitura da umidade e a aplicação da termografia por infravermelho, para estimativa da condutividade hidráulica não saturada do solo em uma bacia hidrográfica representativa, localizada na região de Pesqueira, semiárido pernambucano. Foi monitorada uma rede de pontos de medição de umidade, utilizando uma sonda capacitiva. No primeiro capítulo, os dados de umidade foram avaliados em uma encosta com seis pontos de monitoramento, com cobertura de vegetação natural e pastagem paro o mesmo tipo de solo um Argissolo Vermelho Amarelo. De acordo com o conceito de estabilidade temporal, foi aplicada a técnica de diferenças relativas médias e desvios padrão, para investigar o ponto que fosse capaz de representar o comportamento temporal da média dos demais locais de monitoramento, e a correlação entre os pontos de umidade. No segundo capítulo analisaram-se os padrões de variação temporal em dezessete pontos monitorados de umidade distribuídos em escala de bacia, avaliados para dois tipos de solo: Argissolo Amarelo e Neossolo Regolítico, com duas condições de cobertura do solo, sendo aplicada a técnica de diferenças relativas médias e correlação desses pontos, validam-se o ponto estável seria o mesmo encontrado para encosta. No terceiro capítulo, publicado na revista Quantitative Infrared Thermography Journal, v.11, 2:2014, p.161-169, foi utilizada a técnica da termografia de infravermelho para estimativa da condutividade hidráulica do solo. O estudo foi realizado em laboratório na Universidade de Coimbra, utilizando um canal de terra com declividade e três tipos de solo e uma câmera de vídeo termográfica para registros das imagens. Os dados de condutividade hidráulica estimados com a técnica da termografia infravermelha foram correlacionados com os valores medidos obtidos com um permeâmetro de carga constante, por meio de índices estatísticos e análises de regressão. Para o quarto capítulo, a técnica da termografia foi utilizada em campo para estimativa da condutividade hidráulica não saturada, na bacia do Mimoso para dois tipos de solo, Argissolo Amarelo e o Neossolo Flúvico. Foram aplicadas no solo quatro cargas hidráulicas distintas na superfície do solo, com três repetições e sete ensaios em cada solo em diferentes condições iniciais de temperatura do solo e registros térmicos utilizando uma câmera termográfica. Os registros térmicos foram correlacionados com a condutividade hidráulica não saturada do solo onde apresentaram correlações elevadas. A técnica da dinâmica da umidade permitiu identificar um ponto de estabilidade na bacia. Os registros térmicos permitiram distinção no solo estudado, quando submetidos a diferentes cargas hidráulicas, estando correlacionados com as respectivas condutividades hidráulicas não saturadas. Verificou-se que termografia é uma técnica inovadora capaz de estimar características da condutividade hidráulica não saturada, possibilitando mapeamento das condições de superfície do solo.
7

Hipertermia magnética in vivo com nanopartículas de MnFe2O4 no tratamento de tumores sólidos e subcutâneos de Sarcoma 180 / In vivo magnetic hyperthermia with MnFe2O4 magnetic nanoparticles in the treatment of solid and subcutaneous tumors of Sarcoma 180

Rodrigues, Harley Fernandes 19 April 2017 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2017-05-29T17:22:24Z No. of bitstreams: 2 Tese - Harley Fernandes Rodrigues - 2017.pdf: 14917308 bytes, checksum: 98bd396b4a6b5e7839b6b8ff0fd12102 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-05-30T10:44:17Z (GMT) No. of bitstreams: 2 Tese - Harley Fernandes Rodrigues - 2017.pdf: 14917308 bytes, checksum: 98bd396b4a6b5e7839b6b8ff0fd12102 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-05-30T10:44:17Z (GMT). No. of bitstreams: 2 Tese - Harley Fernandes Rodrigues - 2017.pdf: 14917308 bytes, checksum: 98bd396b4a6b5e7839b6b8ff0fd12102 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-04-19 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Fundação de Amparo à Pesquisa do Estado de Goiás - FAPEG / In this thesis a methodology of real-time monitoring of magnetic hyperthermia (HM) in vivo was developed in the murine tumor model Sarcoma 180 using infrared thermography technique. Magnetic nanoparticles (NPM) consisted of Mn ferrites capable of generating heat at low magnetic field amplitude at the 300 kHz frequency within the safety limit determined by Atkinson. It has been shown that the apparent surface temperature value measured with the infrared camera underestimates the real skin temperature value of the mice if the camera objective does not form an angle 0 ° with the normal direction to the animal's skin in the region of interest on the tumor, with the error reaching more than 7.0 ° C (for 60 °). A new theoretical model to estimate the error in the temperature of curved surfaces was developed and proved valid even in the case where the surface temperature diverges significantly from the environment. Preclinical treatment results indicated a complete remission condition in animal that was submitted to 150 min of hyperthermia and other cases with partial remission, suggesting that biological response analyzes need to be done in a long time (> 60 days). Measurements of the intratumoral temperature monitored by three fiber-optic thermometers during the therapeutic procedure of HM with NPM indicated an inhomogeneous heat delivery within the tumor. Additionally, a new methodology for calculating the thermal dose (CEM43) evaluated at the surface, considering each pixel of the thermographic image as a thermometer in the tumor region, indicated that the value T10(t) of the temperature detected in vivo at the surface of the skin over subcutaneous tumors can report, with an error of the order of 5%, the mean intratumoral temperature value during the therapeutic procedure of HM. / Nesta tese foi desenvolvida uma metodologia de monitoramento em tempo real da hipertermia magnética (HM) in vivo no modelo tumoral murino Sarcoma 180 utilizando a técnica de termografia por infravermelho. As nanopartículas magnéticas (NPM) consistiam de ferritas de Mn capazes de gerar calor em baixa amplitude de campo magnético, na frequência de 300 kHz, dentro do limite de segurança determinado por Atkinson. Foi demonstrado que o valor da temperatura superficial aparente medido com a câmera de infravermelho subestima o valor da temperatura real da pele dos camundongos se a objetiva da câmera não formar um ângulo 0° com a direção normal à pele do animal na região de interesse sobre o tumor, podendo o erro chegar a mais do que 7,0 °C (para 60°). Um novo modelo teórico para estimar o erro na temperatura de superfícies curvas foi desenvolvido e se mostrou válido inclusive para o caso em que a temperatura superficial diverge significativamente da ambiente. Resultados pré-clínicos do tratamento indicaram uma situação de remissão completa em animal que passou por 150 min de hipertermia e outros casos com remissão parcial, sugerindo que análises de resposta biológica precisam ser feitas em longo tempo (> 60 dias). Medidas da temperatura intratumoral monitorada por três termômetros de fibra-óptica durante o procedimento terapêutico de HM com NPM indicaram uma entrega de calor não homogênea dentro do tumor. Adicionalmente, uma nova metodologia para o cálculo da dose térmica (CEM43) avaliada na superfície, considerando cada pixel da imagem termográfica como um termômetro na região do tumor, indicou que o valor de T10(t) da temperatura detectada in vivo na superfície da pele sobre tumores subcutâneos pode informar, com um erro da ordem de 5%, o valor da temperatura média intratumoral durante o procedimento terapêutico de HM.

Page generated in 0.097 seconds