• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 307
  • 107
  • 34
  • 21
  • 20
  • 10
  • 8
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 583
  • 583
  • 315
  • 294
  • 125
  • 89
  • 80
  • 76
  • 70
  • 68
  • 64
  • 64
  • 60
  • 58
  • 54
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
291

Fachada flex?vel para casa padronizada em condom?nios

Albuquerque, Karla Susanna Correia Cavalcanti de 04 April 2012 (has links)
Made available in DSpace on 2014-12-17T13:57:08Z (GMT). No. of bitstreams: 1 KarlaSCCA_DISSERT_Capa_ate_pag49.pdf: 4603204 bytes, checksum: b52448152d451ce76ca78743e0d28711 (MD5) Previous issue date: 2012-04-04 / The employment of flexibility in the design of fa?ades makes them adaptable to adverse weather conditions, resulting in both minimization of environmental discomfort and improvement of energy efficiency. The present study highlights the potential of flexible fa?ades as a resource to reduce rigidity and form repetition, which are usually employed in condominiums of standardized houses; as such, the work presented herein contributes to field of study of architectural projects strategies for adapting and integrating buildings within the local climate context. Two fa?ade options were designed using as reference the bionics and the kinetics, as well as their applications to architectural constructions. This resulted in two lightweight and dynamic structures, which cater to constraints of comfort through combinations of movements, which control the impact of solar radiation and of cooling in the environment. The efficacy and technical functionality of the fa?ades were tested with comfort analysis and graphic computation software, as well as with physical models. Thus, the current research contributes to the improvement of architectural solutions aimed at using passive energy strategies in order to offer both better quality for the users and for the sustainability of the planet / O emprego da flexibilidade no desenho das fachadas, tornando-as adapt?veis a situa??es clim?ticas adversas, conduz a minimiza??o do desconforto ambiental e a efici?ncia energ?tica. Desse modo, esta pesquisa evidencia o potencial de fachadas flex?veis como recurso para diminuir a rigidez e a repeti??o da forma, comumente empregada em condom?nios de casas padronizadas, contribuindo para o aprofundamento no estudo de estrat?gias de projeto que auxiliam na adapta??o e integra??o do edif?cio com o clima e contexto locais. Para tanto, duas op??es de fachadas foram projetadas utilizando como refer?ncia a bi?nica e a cin?tica e suas aplica??es em constru??es arquitet?nicas. Como resultados foram obtidos duas estruturas leves e din?micas que atendem aos condicionantes de conforto por meio de combina??es de movimentos que controlam a radia??o solar e o arrefecimento no ambiente. A efic?cia e funcionalidade t?cnica das fachadas foram testadas por meio de softwares de an?lises de conforto e computa??o gr?fica e simula??es com maquete f?sica. Assim, a pesquisa contribui para o aperfei?oamento de solu??es projetuais objetivando o uso de estrat?gias de energia passiva na arquitetura com o intuito de oferecer melhor qualidade para o usu?rio e para a sustentabilidade do planeta
292

Qualidade do ar interior e conforto t?rmico : um estudo em espa?os de estacionamento em Natal/RN

Costa, Juliana Magna da Silva 13 May 2005 (has links)
Made available in DSpace on 2014-12-17T13:57:10Z (GMT). No. of bitstreams: 1 JulianaMSC.pdf: 2960475 bytes, checksum: ff925978b7f6c5c27eed0072ef0251db (MD5) Previous issue date: 2005-05-13 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / The recent tendency to utilize parking lots for other purposes has demonstrated that more time has been spent by visitors, mainly in great cities. Therefore, this paper investigates the thermal comfort and the air quality indoors in areas specifically used as parking lots by analyzing the direct relation between such environments and vehicular pollution. The thermal comfort and the quality of air indoors in parking lots with different architectonic typology (ground-floor and underground) are also studied, aiming to contribute to the proposition of suitable new areas designated to human usage. Field research was done, in two distinct periods within different weather conditions (January and July) in, two naturally cooled, parking lots located in Natal - RN. The internal environment agents were measured by using tools for air temperature, humidity, speed and direction; interviews with employees and visitors and chemical analysis through appropriate tools to analyze specific material, carbon monoxide and ozone. The results showed that chemical agents densely concentrate mostly in the closed parking space, aggravated by weather conditions, which dissatisfied the visitors. Still, it was shown that architectonic typology, alongside topographical aspects compromise internal environmental conditions, which increases the retention of pollution, leading to dissatisfactory thermal comfort levels and becoming less suitable for usage by visitors considering air and thermal comfort aspects. Consequently, they are not suitable for human stay due to the poor quality of the indoor air / A atual tend?ncia de utiliza??o dos espa?os destinados a estacionamento veicular para outras finalidades tem resultado num tempo maior de perman?ncia dos usu?rios nestes espa?os, principalmente nas grandes cidades. Por esta raz?o, o presente trabalho investiga a qualidade do ar interior e o conforto t?rmico em ?reas reservadas a estacionamentos, atrav?s da rela??o direta destes ambientes com a polui??o veicular. Para realiza??o deste estudo, optou-se por estacionamentos com tipologias arquitet?nicas diferenciadas, sendo um estacionamento aberto e um estacionamento fechado, ambos ventilados naturalmente, situados em Natal/RN, com o intuito de contribuir para a proposi??o de novos espa?os desta natureza adequados ? perman?ncia humana. Para tal, realizou-se pesquisa de campo nos dois estacionamentos em per?odos distintos (janeiro e julho), espa?o de tempo condizente com os per?odos clim?ticos caracter?sticos (ver?o e inverno, respectivamente) da referida cidade. As condicionantes ambientais internas foram mensuradas atrav?s de instrumentos de medi??es da temperatura do ar, umidade relativa do ar, velocidade do ar e dire??o dos ventos; as humanas, atrav?s de entrevistas aplicadas com usu?rios dos locais (visitantes e funcion?rios); e as qu?micas, atrav?s de instrumentos de medi??o apropriados para material particulado, mon?xido de carbono e oz?nio. Na an?lise dos resultados, constatou-se que as condicionantes qu?micas atingiram maiores concentra??es no estacionamento fechado. Este quadro foi agravado pelas condi??es clim?ticas do local (maiores temperaturas do ar), resultando num maior registro de usu?rios insatisfeitos. Constatou-se que a tipologia arquitet?nica de estacionamentos fechados, com contribui??o tamb?m de seu aspecto topogr?fico, compromete as condi??es ambientais internas, potencializando a reten??o de poluentes, acarretando espa?os com baixo ?ndice de conforto t?rmico para seus usu?rios, sendo, assim, menos adequados do ponto de vista da qualidade do ar interior e do conforto t?rmico
293

Qualidade dos espaços públicos viários : ergonomia em escala urbana /

Gasparini Júnior, Roberto Antônio. January 2006 (has links)
Orientador: João Roberto Gomes de Faria / Banca: Léa Cristina Lucas de Souza / Banca: Lucila Chebel Labaki / Resumo: O trabalho analisa o espaço público sob aspectos que envolvem a ergonomia em escala urbana por meio de avaliação pós-ocupação com ênfase em parâmetros comportamentais e de conforto térmico. A pesquisa estuda as condições microclimáticas e morfológicas, relacionando-as com a quantidade e a qualidade de uso para conhecer as influências dessas variáveis no comportamento dos usuários. Para isso, utilizou-se como estudo de caso três vias de Bauru, SP, espaços públicos de grande importância para a cidade, que apresentam diferentes aspectos e diversos tipos de uso. Utilizou-se uma metodologia adaptada que considerou dados quantitativos e também qualitativos, fazendo-se uso também de entrevistas para se conhecer o perfil do usuário e seu grau de satisfação. Os resultados evidenciam a relação entre uso e microclima, bem como entre o uso e outras características peculiares de cada espaço, identificando aspectos positivos e negativos. Objetivou-se também, contribuir com dados que subsidiem intervenções projetuais nos espaços analisados ou em áreas similares. Assim, mostrou-se que o profissional de planejamento deve dedicar especial atenção ao comportamento microclimático gerado com a morfologia como determinantes da qualidade do uso, em garantia do sucesso do espaço público / Abstract: This work analyses the public space under some aspects of ergonomy in urban scale by post-occupation evaluation system based on user's behavior and thermal comfort. The research studies the microclimate and morphological conditions, doing relations with the quantity and quality of the uses to know the influences of these variables on users' behaviors. Then were studied three roads in Bauru, SP, public spaces with great importance for the city, which presents different aspects and various kind of use. An adapted methodology was used to consider quantitative data and also the qualitative ones, doing interviews to know the users' profile and your opinion about the place. The results showed a relationship between use and microclimate, as well as between use and other characteristics of each space, identifying positives and negatives aspects. This study also means to contribute with data to provide information for intervention at the studied spaces or similar areas. Then, the planner must dedicate special attention to the microclimate behavior produced by the morphology like important motive of quality use in this way guarantee the success of the public space / Mestre
294

Estudo t?rmico e de materiais de um comp?sito ? base de gesso e EPS para constru??o de casas populares

Santos, Reginaldo Dias dos 28 July 2008 (has links)
Made available in DSpace on 2014-12-17T14:57:49Z (GMT). No. of bitstreams: 1 ReginaldoDS.pdf: 1111406 bytes, checksum: d55968c3491b3eb05981971626b26f4e (MD5) Previous issue date: 2008-07-28 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / A housing unit was built to study the thermal performance, and of material using a composite made of gypsum and EPS ground. We used two techniques of construction, using blocks, and filling on the spot. Two compositions of the composite were studied. The blocks were fixed using conventional mortar. In the technical of filling on the spot were used PET bottles up inside the walls to provide mechanical and thermal resistance. Compression tests were realized according to the ABNT standard of sealing bricks. It is going to be shown an analysis of the thermal comfort through the use of thermocouples placed on the walls of the building, internally and externally. The manufacturing viability of houses, using recyclable materials, through the use of composite materials proposed will be demonstrated. The constructive aspects showing the advantages and disadvantages of the technique used also will be broached. The block used presents structural functions and thermal insulating, is low cost and represents an alternative to the use of EPS and PET bottles which are materials that end up occupying much space in the landfills, giving than an ecologically correct use. The results of thermal analysis shows the thermal comfort provided by the composite by the obtainment of a difference between the internal and external surfaces of the walls more exposed to the sun around 7? C. The average temperature of the air inside the building, around 28.0 ? C was below the zone of thermal comfort recommended for countries with hot weather / Foi constru?da uma unidade habitacional para estudo de desempenho t?rmico, e de materiais utilizando um comp?sito ? base de gesso e EPS triturado. Foram utilizadas duas t?cnicas de constru??o, usando blocos, e enchimento in loco. Duas composi??es do comp?sito foram estudadas. Os blocos foram assentados utilizando argamassa convencional. Na t?cnica do enchimento in loco utilizou-se garrafas PET no interior das paredes para proporcionar resist?ncias t?rmica e mec?nica. Foram realizados ensaios de compress?o m?nima segundo as normas da ABNT para blocos de veda??o. Foi realizada uma an?lise de conforto t?rmico, atrav?s do uso de termopares colocados nas paredes da edifica??o, interna e externamente. Demonstrar-se-? as viabilidades de fabrica??o de casas, utilizando materiais recicl?veis, atrav?s do uso do material comp?sito proposto. Abordar-se-? tamb?m os aspectos construtivos mostrando as vantagens e desvantagens da t?cnica utilizada. O bloco utilizado apresenta fun??es estruturais e de isolante t?rmico, tem baixo custo e representa uma alternativa para o aproveitamento do EPS e garrafas PET que s?o materiais que acabam ocupando muito espa?o nos aterros sanit?rios, dando-lhe um fim ecologicamente correto. Os resultados da an?lise t?rmica demonstram o conforto t?rmico proporcionado pelo comp?sito pela obten??o de uma diferen?a de temperatura entre as superf?cies interna e externa das paredes mais expostas ao sol em torno de 7? C. A temperatura m?dia do ar no interior da edifica??o, em torno de 28,0? C ficou dentro da zona de conforto t?rmico recomendada para pa?ses de clima quente
295

Obtenção, caracterização e aplicação de microcápsulas em espumas de poliuretano visando o conforto térmico para potencial uso na tecnologia assistiva

Marcuzzo, Leciane Cristina January 2012 (has links)
O design de produto através de suas interfaces multidisciplinares possibilita o desenvolvimento de novas tecnologias destinadas a pessoas com deficiência física. A Tecnologia Assistiva (TA) engloba todo arsenal de recursos e serviços que contribuem para proporcionar ou ampliar habilidades funcionais de pessoas com deficiência e tem como principal exemplo a cadeira de rodas, onde o usuário fica longos períodos na posição sentada e o conforto térmico é necessário. Neste trabalho, desenvolveu-se microcápsulas de eicosano e impregnou-se espumas de poliuretano (PU) com as microcápsulas visando o conforto térmico nessas espumas. O eicosano é um material de mudança de fase (PCM) com temperatura de mudança de fase ao redor de 37°C, que é igual a temperatura de equilíbrio térmico do corpo humano. As microcápsulas inseridas em espumas de poliuretano possuem potencial uso na Tecnologia Assistiva, mais especificamente em assentos de cadeiras de rodas visando o conforto térmico. As microcápsulas foram obtidas através da polimerização in-situ, utilizando resina melamina-formaldeído como invólucro e eicosano como núcleo. As técnicas usadas para a caracterização das microcápsulas envolveram análises de microscopia óptica, microscopia eletrônica de varredura (MEV), granulometria, Espectroscopia do Infravermelho por Transformada de Fourier (FT-IR), Análise Termogravimétrica (TGA) e Calorimetria Exploratória Diferencial (DSC). As microcápsulas de eicosano foram então inseridas em espumas de poliuretano com diferentes densidades e foram analisadas por termografia. As microcápsulas de eicosano impregnadas nas espumas de PU possuem capacidade de absorver ou liberar calor do ambiente circundante e manter a temperatura ao seu redor constante por um determinado período de tempo, sendo assim possuem aplicação potencial na Tecnologia Assistiva, como em assentos de cadeiras de roda por exemplo, devido a sua capacidade de isolamento térmico e absorção ou liberação de calor enquanto ocorre a mudança de fase do eicosano. / The product design through its multidisciplinary interfaces allows de development of new technologies for people with some physical disability. The Assistive Technology (TA) includes all the resources and services that contribute to give and enlarge the functional abilities of people with some disability. The most significant sample of TA resource is the wheel chair, where the person stays long time in the seat position and the thermal comfort is necessary. In this work, microcapsules of eicosane were developed and then polyurethane foams were impregnated with the microcapsules aiming the thermal comfort on the polyurethane foams. The eicosane is a phase change material (PCM) with temperature of phase change of 37°C which is similar to the human body temperature in thermal equilibrium. The microcapsules added to the polyurethane foams have potential use on the Assistive Technology, more specifically on cushion seats aiming the thermal comfort. The microcapsules were obtained by in-situ polymerization using resin melamine-formaldehyde as wall and eicosane as the core. The analysis used to evaluate the properties of the microcapsules were: optical microscopy, scanning electron microscopy (SEM), particle size analysis, fourier transform infrared spectroscopy (FT-IR), thermogravimetry analysis (TGA) and differential scanning calorimetry (DSC). Then the microcapsules of eicosane were added in polyurethane foams with different densities and were analyzed by infrared thermography. The microcapsules of eicosane added to the polyurethane foams present the capacity of absorb or release heat to the environment and maintain the around temperature constant for a period of time. So they have potential application on the Assistive Techology, as wheel chair cushion seats for example, due to its capacity of thermal insulation and absorption or release of heat while occurs the eicosane phase change.
296

Avaliação da legislação brasileira como influência sobre o conforto térmico de edifícios para escritórios em Porto Alegre / Evaluation of the brazilian legislation regarding its influence on the indoor thermal comfort of office buildings in Porto Alegre

Poehls, Lennart Bertram January 2012 (has links)
A presente dissertação propõe avaliar a influência da legislação atual brasileira no conforto térmico no interior de edificações utilizadas como escritório em Porto Alegre no estado do Rio Grande do Sul, Brasil. Para isso, foram avaliadas as horas de conforto para um modelo simplificado através de simulações térmicas. Este trabalho analisa se as prescrições dos textos legislativos resultam em conforto térmico no interior dos ambientes utilizados como escritório através do uso de elementos arquitetônicos abstraídos a partir da legislação brasileira. Para cada uma dos 12 séries, que representam os elementos arquitetônicos abstraídos dos textos legislativos, foram simuladas 5 variações que, por sua vez, consideram 4 orientações solares. A metodologia desenvolve-se a partir das informações obtidas a partir da revisão bibliográfica que se concentra nos fundamentos relacionados ao clima, à legislação brasileira e ao conforto térmico. Os resultados demostram que a legislação brasileira resulta em conforto térmico em apenas algumas das séries consideradas neste trabalho. Note que cada série representa um elemento arquitetônico mencionado na legislação brasileira. Assim, baseado nos resultados obtidos, entre outras conclusões, foi identificada a falta de detalhamento em relação à orientação solar nos textos legislativos em vigor para Porto Alegre. / The present Master thesis proposes a revision of the present Brazilian legislation regarding its influence on the thermal comfort of the internal environments of office buildings in Porto Alegre, situated in the state of Rio Grande do Sul, Brazil. Using computational thermal simulation, the hours of comfort of a simplified model are evaluated to analyse if the values defined in the Brazilian legislation result in confortable interior environments. Inside this case study, a total of 12 series are created and 5 variations are defined for each. All variations are simulated using 4 solar orientations. The methodology is derived from the information obtained during the review of the literature regarding climate, legislation and thermal comfort. The obtained results demonstrate that the Brazilian legislation partially results in offices with thermal comfort. Based on the results and among other conclusions, the work identifies the general lack of details regarding the solar orientation in the legislative texts for Porto Alegre.
297

Análise do conforto térmico de uma edificação de ensino superior em Campina Grande – PB

Souza, Aderson Rodrigues de 25 April 2017 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2017-11-14T13:16:49Z No. of bitstreams: 1 PDF - Aderson Rodrigues de Souza.pdf: 7962462 bytes, checksum: 6f01d4e08ea2460d5c3770f460f086e0 (MD5) / Made available in DSpace on 2017-11-14T13:16:49Z (GMT). No. of bitstreams: 1 PDF - Aderson Rodrigues de Souza.pdf: 7962462 bytes, checksum: 6f01d4e08ea2460d5c3770f460f086e0 (MD5) Previous issue date: 2017-04-25 / The importance of thermal comfort studies in educational buildings is associated with the relationship that this condition has with the performance of human activities, providing a thermally comfortable environment better levels of concentration and attention. Thus, the objective of this research is to evaluate the thermal comfort conditions of classrooms and administrative rooms, naturally ventilated, in a building of higher education, in the city of Campina Grande, Northeast Region of Brazil, where the weather is predominantly hot and humid. In order to obtain the results, two methods traditionally used in this type of research were applied. The analytical method, included in International Standards ISO 7730 (2005) and ASHRAE 55 (2010), provides results on 4 environmental and 2 personal variables, collected from the studied environments. The second method consists in the application of questionnaires to the ordinary users of the environments aiming to obtain personal answers about the real thermal sensations. The analysis of the results showed that the comfort zones, verified in the building, were distinct for each season of the year in which the research was developed. By personal votes, the comfort temperature ranges in the fall were broader than those provided by the technical standards. However, in the winter, the normalized method overestimated the ranges of comfort temperatures obtained by direct votes. The results of the thermal comfort zones were compared with those of other studies done in regions with climatological features similar to those of this work, as well as with those obtained in regions of colder climates, verifying the coherence between the data. This research concluded that, in the autumn season, the environments of the building provided its occupants with thermal discomfort for the heat most of the time, however, in the winter season, thermal comfort situations were predominant. / A importância do estudo do conforto térmico em edificações de ensino está associada ao vínculo que essa condição tem com o desempenho de atividades humanas, para as quais um ambiente termicamente confortável proporciona melhores níveis de concentração e atenção. Assim, o objetivo desta pesquisa é avaliar as condições de conforto térmico de salas de aula e salas administrativas, naturalmente ventiladas, de uma edificação de ensino superior, na cidade de Campina Grande, na Região Nordeste do Brasil, onde o clima é predominantemente quente e úmido. Para obtenção dos resultados, foram seguidos dois métodos tradicionalmente utilizados nesse tipo de pesquisa. O método analítico, constante nas Normas Internacionais ISO 7730 (2005) e ASHRAE 55 (2010), fornece resultados a partir de 4 variáveis ambientais e 2 pessoais, coletadas no interior dos ambientes estudados. O segundo método consiste na aplicação de questionários aos usuários dos ambientes, para a obtenção de respostas pessoais sobre as sensações térmicas reais. A análise dos resultados mostrou que as zonas de conforto, verificadas na edificação, foram distintas para cada estação do ano em que a pesquisa foi desenvolvida. Pelos votos pessoais, os intervalos de temperaturas de conforto, no outono, foram mais amplos do que os previstos pelas Normas. Entretanto, no inverno, o método normatizado superestimou as faixas de temperaturas de conforto obtidas pelos votos diretos. Os resultados das zonas de conforto térmico foram confrontados com os de outras pesquisas feitas tanto em regiões de clima semelhante ao deste trabalho, quanto em locais de clima mais frio, verificando-se coerência entre os dados. A pesquisa concluiu que, na estação do outono, os ambientes da edificação proporcionaram a seus ocupantes situações de desconforto térmico para o calor na maior parte do tempo, todavia, na estação do inverno, as situações de conforto térmico foram predominantes.
298

AmbiÃncia e bem-estar de ovelhas criadas em sistema agrossilvipastoril no semiÃrido cearense. / Ambience and wellness sheep created in agrosylvopastoral system in Cearà semiarid region.

IsmÃnia FranÃa de Brito 14 September 2012 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / This study aimed to establish the physiological parameters of ewes reared in agrosilvopasture system in the northeast semiarid and hence assess environmental conditions offered by the system. Thus, 22 crossbred ewes were selected and evaluated during the dry and rainy seasons, considering the following physiological parameters: heart rate (HR), respiratory rate (RR), surface temperature (ST) and rectal temperature (RT) during shifts morning and afternoon. Six mini-stations and meteorological Data Loggers were used to record the data of temperature and relative humidity. It was calculated the Enthalpy Index of Comfort (EIC) for evaluating the thermal comfort. It was observed that the temperature was higher in the dry season compared to the rainy season and the RR presented significant difference (P <0.05) between the morning and afternoon during the rainy season. Statistical difference was observed (p <0.05) for both HR between the dry and rainy seasons, as between morning and afternoon shifts. As for the ST, a significant difference (p <0.05) was detected between the morning and afternoon and between the dry and rainy seasons. For TR, the data showed no statistical difference (p> 0.05) for the afternoon shift, between the two periods evaluated. The sexual behavior of animals was also monitored and, through an ethogram, the following parameters were evaluated: proximity to male (PM); urination (U); smells the male (SM); licks the male (LM); mounts the male (MM); remains immobile with the male sniffing (RIMS); wags/raises the tail (W/RT); mounts the females (MF); allows to assemble by females (AAF) and accepts the mount (AM). It was observed that PM, U, RIMS, SM and WRT showed a significant relationship (p <0.05) with acceptance of mount. The demonstration of the sexual conduct of females studied was not affected by the climatic parameters. The rectal temperatures were 38.1 ÂC for females that showed estrus during the morning and 38.7 ÂC for the afternoon shift. The animals showed normal sexual behavior in estrus and the rectal temperature of ewes remained in the normal limits. Overall, the system agrosilvopastoral evaluated in this study ensured favorable conditions for thermal comfort and well being of the animals. / Objetivou-se estabelecer os parÃmetros fisiolÃgicos de ovelhas criadas em sistema agrossilvipastoril no SemiÃrido Nordestino e, consequentemente, avaliar as condiÃÃes ambientais oferecidas aos animais por esse sistema de criaÃÃo. Assim, foram selecionadas 22 ovelhas mestiÃas, avaliadas durante as Ãpocas seca e chuvosa, quanto aos seguintes parÃmetros fisiolÃgicos: frequÃncia cardÃaca (FC); frequÃncia respiratÃria (FR); temperatura superficial (TS) e temperatura retal (TR), durante os turnos da manhà e tarde. Seis miniestaÃÃes meteorolÃgicas e Data Loggers foram utilizadas para o registro dos dados de temperatura e umidade relativa do ar. Foi calculado o Ãndice Entalpia de Conforto (IEC) para a avaliaÃÃo do conforto tÃrmico. Foi possÃvel observar que a temperatura mostrou-se mais elevada no perÃodo seco em comparaÃÃo ao perÃodo chuvoso; que a FR apresentou diferenÃa significativa (P<0,05) entre os turnos da manhà e da tarde no perÃodo chuvoso. Foi observada diferenÃa estatÃstica (p<0,05) para a FC tanto entre as Ãpocas seca e chuvosa, quanto entre os turnos manhà e tarde. Quanto à TS, esta apresentou diferenÃa (p<0,05) entre os turnos da manhà e tarde e entre as Ãpocas seca e chuvosa. Para TR, os dados mostraram que nÃo houve diferenÃa estatÃstica (p>0,05) para o turno da tarde, entre as duas Ãpocas avaliadas. Foi monitorada ainda a conduta sexual dos animais e, por meio de um etograma, foram avaliados os seguintes parÃmetros: proximidade ao macho (PM); micÃÃo (M); cheira o macho (CM); lambe o macho (LM); monta no macho (MM); mantÃm-se imÃvel com o macho cheirando (IMC); abana/levanta a cauda (ALC); monta nas fÃmeas (MF); deixa-se montar pelas fÃmeas (DMF) e aceita a monta (AM). Observou-se que PM, M, IMC, CM e ALC apresentaram uma relaÃÃo significativa (p < 0,05) com a aceitaÃÃo da monta. A demonstraÃÃo da conduta sexual das fÃmeas estudadas nÃo foi afetada pelos parÃmetros climÃticos. As temperaturas retais foram de 38,1 ÂC para as fÃmeas que apresentaram estro no turno da manhà e 38,7 ÂC para as do turno da tarde. Os animais apresentaram comportamento sexual normal de ovelhas em estro e a temperatura retal das ovelhas se manteve dentro da normalidade. De forma geral, o sistema agrossilvipastoril avaliado nesta pesquisa assegurou condiÃÃes favorÃveis de conforto tÃrmico e bem estar aos animais.
299

Otimização de parâmetros de projeto de tubulações de sistemas de calefação por piso radiante. / Optimization of piping design parameters for a radiant floor heating system.

María Carolina Díaz Rastello 02 September 2013 (has links)
Devido à climatização dos ambientes internos condicionar o bem estar e o conforto térmico das pessoas é que se fazem necessárias novas pesquisas que procurem potencializar as tecnologias existentes e reduzir tanto os custos de instalação quanto o consumo de energia. É sabido que os sistemas convencionais de calefação proporcionam um alto consumo de energia e uma emissão de níveis de ruído muitas vezes inaceitáveis, entretanto os sistemas radiantes ganham, a cada dia, uma maior abrangência como alternativa de climatização devido às suas vantagens comparativas com relação aos sistemas convencionais. O emprego de sistemas de calefação por piso radiante em muitos países é limitada pelo preço da instalação como consequência do elevado custo dos materiais como é o caso da fabricação das tubulações. Estas geralmente são fabricadas de polietileno ou de cobre, sendo este ultimo o que entrega um maior desempenho térmico e, por conseguinte um melhor fornecimento de energia, mas o elevado custo deste material restringe o seu uso principalmente ao setor residencial, podendo atingir um mercado maior que compreenda edifícios públicos, de escritório, escolas, hospitais, etc. Com isso, este trabalho procura reduzir a quantidade de materiais de tubulação necessários para garantir o desempenho do sistema e o conforto térmico de uma habitação aquecida com um sistema radiante. Para isto, foi desenvolvida a resolução numérica do modelo matemático da transferência de calor no interior do piso pelo método dos volumes finitos na formulação implícita e implementada em código computacional na linguagem Matlab. Para isto, foram considerados dois parâmetros fundamentais para garantir o conforto térmico da habitação que correspondem à temperatura da água e a distancia entre os tubos que compõem o sistema. A análise corresponde ao cálculo da temperatura superficial do piso para distintas temperaturas da água e distintas distâncias, obtendo resultados interessantes que permitem reduzir o custo da instalação em até um 40%. / Due to temperature control of interiors conditioning the well-being and the thermal comfort of people, it is necessary to make new researches aiming to improve the existing technologies and to reduce both installation costs and energy consumption. It is known that the use of traditional heating systems involves high energy consumption and, in some cases, unacceptable noise levels; while radiant systems are gaining a wider scope as a heating alternative due to its advantages compared to conventional systems. The use of radiant floor heating systems in Brazil is limited by installation cost due to the high price of required materials. This fact restricts the use of these systems primarily to the residential sector. However, it may be possible for this technology to reach a larger market, including public buildings, offices, schools and hospitals. Therefore, to optimize the most relevant design parameters relating to the thermal performance of the system and reduce both the amount of required materials and the system operating time, this paper elaborates on a method consisting of a high-resolution numerical mathematical model of the heat transfer within a floor using a finite control volume method with an implicit solution scheme. In this work, we consider how the properties of the materials, environmental thermal comfort factors and the performance of the system work together with the theoretical underpinnings of the heat transfer phenomenon to define the design parameters to optimize the materials and provide greater control over the energy consumption. This optimization is achieved without changing any environmental thermal comfort conditions or the well-being of the occupants. Finally, a numerical solution for the heat transfer within the floor is implemented using the computer code Matlab.
300

AnÃlise do conforto tÃrmico em habitaÃÃes de interesse social no Bairro SumarÃ, MunicÃpio de Sobral, Cearà / Analysis of thermal comfort in social housing in the neighborhood SumarÃ, Municipality of Sobral, CearÃ

Marta NÃlia Alves Braga 13 August 2013 (has links)
CoordenaÃÃo de AperfeÃoamento de Pessoal de NÃvel Superior / One of the roles of housing is to protect individuals from the weather to which they are subject, saving inside a protection against the severities of the climate. When the house does n ot respect this principle of comfort, individuals are subject to the emergence of physical or psychosocial disorders. Studies show that thermal comfort directly influences productivity at work (Oliveira et al, 2010.), Yield of studies (Batiz; GOEDERT; MORS CH; Kasmirski - Jr; Venske, 2009) and especially in population health (Araujo, 2012). In this context, the main residents are affected as to mitigate the discomfort in their homes, they need to use artificial means of cooling, almost always, inconsistent wit h its income group. The proposed study aims to evaluate the thermal performance of single - storey and single - family dwellings built and in use Sumarà neighborhood in the city of Sobral / CearÃ, and the thermal comfort of its users. To this end, we preserve housing characteristics of the original design were chosen. Selected dwellings are part of a city program to build housing in order to meet the population living in risk areas prone to flooding. The method used for performance evaluation based on requireme nts and criteria proposed by the NBR 15220 (ABNT, 2005), which are obtained from the mathematical calculation of thermal parameters that consider the performance of the building components. It was also evaluated the perceptions of users through questionnai res that were applied in July and August 2013 The degree of satisfaction was checked according to the Estimated Mean Vote (PMV - Predicted Mean Vote) suggested by Fanger and regulated by the International 7730 Organization for Standardization (ISO, 2005) a nd American Society of Heating, Refrigerating and Air - Conditioning Engi neers (ASHRAE, 2004). In parallel, measurements were made of the internal and external temperatures using thermo - hygrometer to compare with the opinion of the respondents. The results show that the tested housing have poor thermal performance. Regarding the results of the interviews, it can be noticed that the calculated thermal performance reflects the opinion of respondents who consider their thermally uncomfortable dwellings. / Um dos papÃis da moradia à resguardar os indivÃduos das intempÃries a que estÃo sujeitos, conservando em seu interior uma proteÃÃo contra as severidades do clima. Quando a moradia nÃo respeita esse princÃpio de conforto, os indivÃduos ficam sujeitos ao surgimento de patologias fÃsicas ou psicossociais. Estudos mostram que o conforto tÃrmico influencia diretamente na produtividade no trabalho (OLIVEIRA et al., 2010), no rendimento dos estudos (BATIZ; GOEDERT; MORSCH; KASMIRSKI-Jr; VENSKE, 2009) e, principalmente na saÃde da populaÃÃo (ARAUJO, 2012). Nesse contexto, os moradores sÃo os principais afetados, pois, para mitigar a sensaÃÃo de desconforto em suas habitaÃÃes, necessitam utilizar meios para climatizaÃÃo artificial, quase sempre, incompatÃvel com a sua faixa de renda. O trabalho proposto tem como objetivo, avaliar o desempenho tÃrmico de habitaÃÃes tÃrreas e unifamiliares construÃdas e em uso no bairro SumarÃ, no municÃpio de Sobral/CearÃ, e o conforto tÃrmico de seus usuÃrios. Para tanto, foram escolhidas habitaÃÃes que preservassem caracterÃsticas do projeto original. As habitaÃÃes selecionadas fazem parte de um programa municipal para construÃÃo de moradias, a fim de atender a populaÃÃo que vive em Ãrea de risco sujeitas a inundaÃÃes. O mÃtodo utilizado para a avaliaÃÃo de desempenho baseia-se em requisitos e critÃrios propostos pela NBR 15220 (ABNT, 2005), que sÃo obtidos a partir do cÃlculo matemÃtico de parÃmetros tÃrmicos que consideram o desempenho de componentes da edificaÃÃo. Avaliou-se, tambÃm, a percepÃÃo dos usuÃrios atravÃs de questionÃrios que foram aplicados nos meses de julho e agosto de 2013. O grau de satisfaÃÃo foi verificado segundo o Voto MÃdio Estimado (PMV â Predicted Mean Vote) sugerido por Fanger e normatizado pela International Organization for Standardization 7730 (ISO, 2005) e American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE, 2004). Em paralelo, fizeram-se aferiÃÃes das temperaturas internas e externas usando termo-higrÃmetro para comparar com a opiniÃo dos entrevistados. Os resultados mostram que as habitaÃÃes avaliadas possuem desempenho tÃrmico insatisfatÃrio. Quanto aos resultados das entrevistas, pode-se perceber que o desempenho tÃrmico calculado reflete a opiniÃo dos entrevistados que consideram suas habitaÃÃes termicamente desconfortÃveis.

Page generated in 0.0459 seconds