• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 307
  • 107
  • 34
  • 21
  • 20
  • 10
  • 8
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 583
  • 583
  • 315
  • 294
  • 125
  • 89
  • 80
  • 76
  • 70
  • 68
  • 64
  • 64
  • 60
  • 58
  • 54
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
311

Alojamento de cachaços em instalações climatizadas : analise de desempenho reprodutivo e do uso de energia eletrica / Accommodation of boars in acclimatized facilities : analysis of reproductive performance and use of electric energy.

Velloso, Nina Miglioranza 29 February 2008 (has links)
Orientador: Luiz Antonio Rossi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-11T08:27:55Z (GMT). No. of bitstreams: 1 Velloso_NinaMiglioranza_M.pdf: 2115577 bytes, checksum: a41a9cbebf41a1039131c1d816d64d5e (MD5) Previous issue date: 2008 / Resumo: A importância da suinocultura brasileira no contexto socioeconômico do país é cada vez mais evidente. Por ser uma atividade que gera milhares de empregos anualmente, além de incrementar o produto interno bruto da nação por meio das expressivas exportações da carne suína, cada vez mais atenção é despendida com os requerimentos dos animais. Apesar disso, pouco tem sido pesquisado sobre as exigências de uma categoria em especial, a dos machos reprodutores do plantel, que são extremamente susceptíveis a condições climáticas adversas. Deste modo, torna-se importante a realização de estudos acerca dos requisitos necessários para mantê-los em conforto térmico, visto que são grandes as perdas na produção devido aos dias muito quentes e às grandes amplitudes térmicas. Uma alternativa para minimizar estas perdas é o uso de sistemas de climatização. Este trabalho teve por objetivo avaliar dois grupos de cachaços, grupos A e B, alojados, respectivamente, em instalações climatizadas por meio de sistema automatizado de ventilação artificial e nebulização, e em instalações climatizadas apenas por ventilação artificial e seguindo o manejo de acionamento dos ventiladores já praticado na propriedade. Foram considerados aspectos de desempenho reprodutivo e conforto térmico dos animais e do uso de energia elétrica pelos equipamentos de climatização. O experimento foi conduzido em uma granja comercial localizada na cidade de Capivari/São Paulo, com animais de uma mesma linhagem genética. O parâmetro utilizado na comparação do desempenho reprodutivo dos animais de ambos os grupos foi a análise das características do sêmen, que se relacionam diretamente com a taxa de prenhez das fêmeas. As edificações de alojamento dos animais também foram comparadas, avaliando-se variáveis climáticas, custos operacionais, gastos com equipamentos de climatização e automação, além da utilização da energia elétrica por parte dos mesmos. Os principais resultados obtidos demonstraram que o sistema de climatização automatizado manteve os animais em uma condição ambiental mais segura, porém não houve melhora nos índices de qualidade seminal dos animais deste grupo. Os valores médios de volume seminal e concentração espermática foram superiores nos animais do grupo B. Os impactos no custo mensal da conta de energia elétrica do posto transformador que fornece energia elétrica para a instalação dos cachaços foram de 2,26% e de 4,82%, para os dois meses completos avaliados / Abstract: Swine grow activities in Brazil is exhibiting an increasing importance to the national social economy. The particular attention devoted to the animal physical requirements is strongly supported by the direct and indirect job opportunities generated as well as by the significant swine meet exportation which push the national internal gross product to high levels. In spite of that, little research efforts has been directed to a special animal group identified as the breeding stock reproducing males, which are very susceptible to temperature changes. That information gives support to a deep study on animal thermal comfort, which is strongly associated to production losses and to the thermal amplitude variations. The application of environmental controlling systems aims to minimize these above referred losses. This research work aimed to evaluate two groups of males, named group A and group B, kept under artificial automatic ventilation and nebulization, as well as only under artificial ventilation following the traditional fan operation, respectively. Factors as reproducing performance, animal thermal comfort, as well as electrical energy use by the environment controlling system have been considered. Experimental trials were carried in a swine growing facility located at Capivari, SP, Brazil by employing animals belonging to a same commercial genetic group. Semen characteristics were employed as a factor of comparison, which are associated to the female pregnancy rate. The shelter¿s building of those animals were also compared, by assessing up climatic variables, operating costs, spending on air conditioning equipment and automation, and the use of electric energy by them. The main results showed that the automated system of air conditioning kept the animals in a safer environmental condition, however there was no improvement in seminal quality scores for the animals of this group. The mean values of seminal volume and sperm concentration were higher in the animals of group B. The impacts on the cost of monthly account of electric energy of the post processor, which provides electricity for the installation of males, were 2.26% and 4.82% for the two whole months assessed. / Mestrado / Construções Rurais e Ambiencia / Mestre em Engenharia Agrícola
312

Projeto Com-test: estudo de características dos tecidos relacionadas com o conforto térmico de vestimentas destinadas à proteção de riscos de origem térmica / Com-test Project: study of fabric features related to thermal comfort of clothes designed to protect from termal hazards

Cristina Salete Valentin 17 November 2015 (has links)
Em função de uma forte e crescente demanda do mercado consumidor de vestuário de proteção por maior conforto, considerando entre outros aspectos o fato que o conforto interfere no uso e proteção, aliado ao fato do Brasil ter clima predominantemente quente e úmido, e a inexistência de trabalhos e estudos referentes ao tema na área, este trabalho objetivou realizar um estudo das características relacionadas ao conforto, dos têxteis, (tecidos), utilizados nas vestimentas destinadas à proteção frente a riscos de origem térmica (calor e fogo) no mercado brasileiro. Após a seleção de onze produtos como objeto de estudo da pesquisa, realizou-se ensaios de transporte de umidade em tecidos, resistência ao vapor de água, ensaios de conforto físico e ergonômico (ensaio de massa laminar e Kawabata Evalution System (KES), e o Termo Labo II para avaliação da condutividade térmica e propriedades de retenção de calor / Consumers, while seeking for more comfort, have a strong and growing demand for protective clothing. Considering that comfort interferes on the use and protection, and also taking into account that Brazilian weather is predominantly hot and humid and there are no papers or studies about this subject, this work aimed to study the features related to the comfort of fabrics that are used to make clothes designed to protect from thermal hazards (heat and fire) in Brazilian market. After selecting eleven products as objects of the research, we performed tests of humidity transportation on fabrics, water vapor resistance, physical and ergonomic comfort (laminar mass test and Kawabata Evaluation System (KES) and Labo II Term for evaluation of thermal conductivity and heat retention properties
313

Dimensionamento e avaliação do ciclo de refrigeração de sistema de climatização automotivo. / Sizing and evaluation of an automotive climate system refrigeration cycle.

Eduardo Oliveira dos Santos 02 September 2005 (has links)
O ser humano consome grandes quantidades de energia para satisfazer as suas necessidades de conforto. Dentro do setor automotivo, depois da energia consumida com a mobilidade em si, o ar condicionado é o maior consumidor. O sistema de climatização para aplicações automotivas tem características particulares, diferentes de sistemas de climatização para outros ambientes. Em uma aplicação automotiva a variação de condições é bastante significativa, como por exemplo, a carga solar que é imposta, a velocidade do veículo, umidade do ar, as temperaturas interna e externa, variação do número e da posição dos ocupantes no interior do veículo, diferentes regimes de rotação e carga do motor, etc. O sistema deve, portanto, ser projetado para funcionar sob todas estas condições e propiciar condições de conforto térmico com o menor consumo de energia. No presente trabalho o objetivo é o projeto e a simulação de um ciclo de refrigeração que atenda aos requerimentos de carga térmica para um automóvel compacto em um ensaio específico realizado em túnel de vento. A partir da carga térmica, o ciclo de refrigeração é dimensionado seguindo-se o procedimento de projeto, que engloba o dimensionamento dos componentes principais como compressor, condensador, evaporador e o dispositivo de expansão. Os resultados dos cálculos teóricos são comparados com o dimensionamento do veículo real, permitindo se chegar a conclusões sobre o projeto. A avaliação do desempenho do sistema projetado é realizada por meio de um procedimento de simulação proposto, e os resultados comparados com os do veículo testado. O objeto de estudo é o sistema de refrigeração de um veículo compacto de quatro portas de fabricação nacional, submetido a um teste de desempenho do ciclo em um túnel de vento. O procedimento de dimensionamento pode ser usado para o projeto básico do sistema de refrigeração. Os resultados obtidos com o modelo de simulação proposto são bastante razoáveis. O modelo pode ser utilizado para prever o resultado de modificações no ciclo de refrigeração, como a troca de componentes, ou mesmo para prever o funcionamento do sistema sob outras condições de operação. A utilização do modelo fica restrita aos limites da validade dos modelos semi-empíricos dos componentes, não sendo recomendada a utilização fora desses limites. Ainda assim, a faixa de aplicação é grande o suficiente para simular a maioria das condições de trabalho encontradas na climatização veicular. / Human being spends a large amount of energy to satisfy its comfort needs. In the automotive applications, air conditioning is the second larger energy consumption system, after the mobility system itself. The refrigeration system for automotive application has peculiar characteristics, which are different from other refrigeration systems (e.g. buildings, food refrigeration, etc). In an automotive application, variation of several conditions are highly significant, such as the sun load, ambient temperature and humidity, the number and position of the occupants inside the vehicle, different engine loads and speeds and so on. The system must, therefore, be designed to operate satisfactorily under all these conditions and to provide thermal comfort with smallest possible energy consumption. The objective of this work is to present the project and simulation of a refrigeration cycle for a compact size vehicle in order to meet thermal load requirements of a specific wind tunnel test. From the thermal load, the refrigeration cycle is designed according to a design procedure, which includes the sizing of main components such as compressor, condenser, evaporator and expansion device. The results of the calculations are compared with the actual vehicle design. The performance evaluation is achieved by using a proposed simulation procedure, and the simulation results are compared with the actual vehicle test results. The study is conducted on the refrigerating system of a 4-door compact size vehicle locally manufactured, which was submitted to a refrigeration cycle performance test in a wind tunnel. The design procedure can be used for sizing a baseline refrigeration cycle. The results achieved with the proposed simulation model are acceptable. The model can be used to predict the impact of a modification in refrigeration cycle such as a component change, or even to predict the system balance point under different operating conditions. The application of the model is restricted to the range of validation of the component semiempirical models, so that the use beyond these limits is not recommended. The range of application, however, is wide enough to accommodate most of the operating conditions found in the vehicular refrigeration applications.
314

Avaliação do conforto térmico e do nível de CO2 em edifícios de escritório com climatização artificial na cidade de São Paulo. / Thermal comfort and CO2 level evaluation in air-conditioned office biuldings in São Paulo.

Eliane Hayashi Suzuki 18 October 2010 (has links)
O conforto térmico e a qualidade do ar interior são fatores importantes a serem considerados tanto na fase de projeto quanto na operação dos edifícios. Este trabalho tem como objetivo avaliar as condições do ambiente térmico durante operação do sistema de condicionamento de ar por meio de medições em campo no período de verão. A pesquisa foi realizada em nove edifícios corporativos com climatização artificial na cidade de São Paulo, que foram selecionados conforme critérios pré-estabelecidos de sistema central com distribuição de ar por dutos. A estratégia de medição e o dimensionamento estatístico do número de amostras por edifício foram determinados de acordo com os resultados das primeiras medições. Coletaram-se os dados dos parâmetros ambientais com instrumentação correspondente em três pavimentos aleatórios de cada edifício. Posteriormente, compararam-se os dados com os níveis estipulados por normas técnicas nacionais e internacionais de conforto térmico e qualidade do ar interior, a fim de verificar a eficiência dos sistemas de distribuição de ar dos edifícios pesquisados no que diz respeito à remoção de poluentes, baseado na medição da concentração de dióxido de carbono, e ao provimento do conforto através da análise de variáveis como temperatura, umidade relativa e velocidade do ar. Os resultados mostraram que a maior parte da amostra se enquadrou nas categorias de ambientes térmicos estabelecidos pelas normas e que existe um potencial de conservação de energia nos edifícios de escritório em São Paulo. / Thermal comfort and indoor air quality are important factors to be considered during building design and operation. This study aims to evaluate thermal environment conditions during air conditioning system operation through field measurements in summer. The survey was conducted in nine office buildings with mechanical cooling in São Paulo. Measurement strategy and statistical determination of the number of samples per building were determined in accordance to the results of initial measurements. Environmental parameters data was collected with corresponding instrumentation in buildings and then compared with the levels required by national and international standards for thermal comfort and indoor air quality in order to verify air distribution efficiency in regard of pollutants removal, based on carbon dioxide concentration, and the provision of comfort through the analysis of variables such as temperature, relative humidity and air velocity. The results showed that most of the sample fitted into the categories of thermal environment established by the standards and that there is potential for saving energy in air-conditioned buildings in Sao Paulo.
315

Simulação numérica de difusores tangenciais com modelo de tensões de Reynolds. / Numerical simulation of swirl diffusers with Reynolds stress model.

Rafael de Freitas Sartori 20 September 2013 (has links)
Difusores de ar é um tema de particular interesse na indústria dos sistemas de ar condicionado e climatização. O difusor swirl (ou tangencial) é um tipo de difusor já utilizado em alguns ambientes climatizados. O seu comportamento é mais conhecido em aplicações no campo da combustão, mas, em aplicações de sistemas de ar condicionado o Número de Reynolds é bem menor, não há a combustão e as condições de contorno são diferentes. Além disso, têm-se poucos estudos voltados para estes difusores num domínio 3D. Com esta motivação, o presente trabalho apresenta as simulações de um difusor tangencial em vazões típicas de aplicações de conforto térmico personalizado, utilizando a modelo de turbulência Reynolds Stress em um domínio 3D. Algumas simulações em um domínio 2D são realizadas a fim de se obter algumas características essenciais do escoamento, como abertura e comprimento do jato. Porém, comparados ao experimento, os resultados 2D precisam ser melhorados. Esquemas de discretização de maior ordem são utilizados para se avaliar o desempenho. Nas simulações no domínio 3D, verifica-se que um resultado melhor é alcançado quando se refina a malha na região central do jato, logo abaixo do difusor. Dois métodos de especificação da condição de contorno de entrada são estudados: o primeiro consiste em utilizar os dados experimentais obtidos na saída do difusor para simular o escoamento sem a geometria do difusor e o segundo simula o difusor completo, aplicando a magnitude da velocidade perpendicularmente à superfície de entrada com base na vazão calculada pelos dados do experimento do PIV (Particle Image Velocimetry). Os resultados numéricos são comparados com o experimento. Verifica-se que o método de simulação sem o difusor apresenta resultados mais precisos com relação ao experimento e apresenta maiores vantagens na simulação numérica. / Air diffusers are a topic of particular interest in the industry of acclimatization and air conditioning systems. The swirl (or tangential) diffuser is a type of device already used in some air conditioned environments. Their behavior is best known in combustion applications, but in air conditioning systems applications, the Reynolds number is much lower, there is no combustion and the boundary conditions are different. In addition, there have been few studies on these diffusers in 3D domain. With this motivation, this work presents simulations of a tangential flow diffuser for applications of thermal comfort. The numerical study uses the Reynolds stress turbulence model in a 3D domain. Some simulations in a 2D domain are performed in order to obtain some essential features of the flow, as the width and length of the jet. However, compared to the experiment, the 2D results need to be improved. Higher order discretization schemes are used to evaluate performance. In 3D domain simulations, it is verified that a better result is achieved when the mesh is refined in the jets central region, just below the diffuser. Two methods of the inlet boundary conditions are studied: the first consists of using the experimental data obtained at the exit of the diffuser to simulate the flow without the geometry of the diffuser and the second method simulates the diffuser completely, applying the velocity magnitude perpendicular to the inlet surface based on the calculated flow rate with experimental data of PIV (Particle Image Velocimetry). The numerical results are compared with experiment. It is noted that a simulation method without the geometry of the diffuser provides more accurate results with the experiment and has major advantages in the numerical simulation.
316

Áreas verdes hospitalares - percepção e conforto / Hospital Green areas Perception and Comfort

Léa Yamaguchi Dobbert 18 January 2011 (has links)
Nas primeiras décadas do século XX, profissionais da área da saúde investiram em ambientes funcionais de trabalho, dando ênfase à implantação de equipamentos de alta tecnologia, sem se preocuparem com o grau de conforto proporcionado pelo ambiente físico. Trabalhos científicos nesta área classificaram esses espaços como estressantes e inadequados em razão de não observarem as carências emocionais e psicológicas dos usuários. O presente estudo avaliou a melhoria do conforto humano na Irmandade Santa Casa de Valinhos/SP-Brasil, proporcionado pela requalificação de áreas verdes existentes entre as alas de internação. Para avaliar o grau de conforto térmico proporcionado por essas áreas verdes requalificadas, utilizaram-se dois modelos preditivos de conforto: o Predicted Mean Vote - PMV (FANGER, 1970) e o Predicted Percentage of Disatisfied - PPD baseado na ISO 7730 (1994) para ambientes internos. A fim de se compararem os resultados obtidos com base nos modelos preditivos à percepção subjetiva do conforto térmico dos entrevistados, foram aplicados questionários contendo questões abertas e fechadas que possibilitaram uma análise dos benefícios terapêuticos proporcionados pelas áreas verdes requalificadas. Outro instrumento utilizado, o Inventário de Sintomas de Stress de LIPP, avaliou e comparou o nível de stress entre dois grupos de funcionários (com contato e sem contato com áreas verdes). Os resultados deste estudo demonstram que os espaços verdes requalificados, apesar de ainda não interferirem no grau de conforto térmico dos ambientes a eles adjacentes, cumprem um papel terapêutico na medida em que promovem maior bem-estar a todos que deles se usufruem. / In the first decades of the twentieth century, health professionals have invested into functional work environments, emphasizing the insertion of high-tech equipment and not concerned about the comfort provided by the physical environment. Scientific work in this area ranked these spaces as stressful and inappropriate in order not to observe the emotional and psychological necessities the users have. This study has evaluated the improvement of human comfort in Santa Casa de Valinhos / SP-Brazil, provided by the recovery of green areas between the internment wards at the hospital. To evaluate the thermal comfort degree provided by these recovered green areas, we have used two predictive comfort models: Predicted Mean Vote - PMV (FANGER, 1970) and Predicted Percentage of Disatisfied - PPD based on ISO 7730 (1994) for indoor environments. In order to compare the results based on predictive models to the subjective perception of the thermal comfort, questionnaires have been applied with open and closed questions which have allowed an analysis of therapeutic benefits provided by the recovered green areas. The other instrument used was Lipp Stress Symptom Inventory, which evaluated and compared the level of stress among two staff groups (with or without contact to the green areas). The results of this study have demonstrated that the recovered green spaces, while not influencing the thermal comfort degree of adjacent environments, which has a therapeutic role while promoting a greater well-being to all who enjoy them.
317

Níveis de proteína bruta e balanço eletrolítico para frangos de corte / Levels from protein and electrolyte balance for broiler

Navarini, Franciele Clenice 29 May 2009 (has links)
Made available in DSpace on 2017-07-10T17:48:17Z (GMT). No. of bitstreams: 1 Franciele_Navarini.pdf: 271642 bytes, checksum: 28a7bcd130b21facc8ae729e942c43b9 (MD5) Previous issue date: 2009-05-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Four experiments were conducted to evaluate the effects of different electrolyte balance and crude protein in feed for broiler chickens Cobb male line reared in natural conditions of heat stress. In experiment 1, were used 880 chicks in the period from 1 to 7 days of age with an average weight of 52,00 grams. Being housed 22 chicks per experimental unit, comprising a density of 14.10 chicks.m-2 housed in 40 boxes were distributed in a completely randomized design with 8 treatments, five replications. In experiment 2, were used 800 chicks in the period from 8 to 21 days of age with an average weight of 160,00 grams. Being housed 20 chicks per experimental unit, comprising a density of 12.82 chicks.m-2. In experiment 3, were used 640 chicks in the period from 22 to 35 days of age with an average weight of 640 grams. Being housed 16 chicks per experimental unit, comprising a density of 10.25 chicks.m-2. In experiment 4, were used 480 chicks, with an average weight of 1,700 grams, the period from 36 to 42 days of age. Being housed 12 chicks per experimental unit, comprising a density of 7.69 chicks.m-2. The diets were formulated from corn, soybean meal and maize gluten to meet the nutritional requirements of chicks in all experiments, according to Rostagno et al. (2005), except for crude protein whose levels were calculated, considering the levels recommended reducing 5%, 10% and 15%, and two electrolyte balance (200 and 240 mEq.kg-1) in all experiments. The animals received water and food ad libitum. In all the experiments was evaluated zootechnical performance (average gain of weight, average consumption of feed, feed conversion and final weight), and developing bone (index Sedoor). The environmental conditions of the building were monitored six times a day to help the hygrometer, a black globe thermometer and the readings used to calculate the of Black Globe Temperature and Humidity Index (BGHI). During the experimental period, the values of temperature, relative humidity, temperature and black globe BGHI remained above the zone of thermo neutrality of broilers. For the variables of performance in all experiments, except for experiment 4, the chicks had greater weight gain and final weight with the balance of 240 mEq.kg-1. In all experiments, the chicks that received diets with reduced levels of CP showed lower performance on fed diets without reducing protein, independent of the BE. This result is most evident in the diet with a reduction of 15% CP. With regard to blood tests, as reduced levels of CP in the diet, also decreased the concentration of uric acid in serum (p <0.05). For the electrolyte balance of 200 mEq.kg-1 saw the highest amount of calcium in blood serum. The chicks had lower percentage of total protein in blood stock in the range of 240 mEq.kg-1, the average levels of total protein in blood that range from 2.36 (experiment 4) to 2.92 mg.dL-1 (experiment 2) and below 3.6 mg.dL-1, are considered normal. The concentrations of K +, Cl-(Experiment 4) were not influenced (p> 0.05) by treatments. In relation to the concentration of sodium at 21 days of age (Experiment 2), the reduction of diet crude protein decreased (p <0.05) the concentrations of this mineral in serum. This response, however, was not observed at 42 days of age (Experiment 4). For evaluation of bone development, only the levels of CP protein used in the experiment 3, linearly affect the rate of Seedor femur (P <0.05). The effect of GA on the levels of Seedor index was not significant (P <0.05) for all experiments. For chickens from 22 to 35 days of age, levels of CP in the diet caused a linear effect and decreasing the rate of Seedor femur. Only in experiment 1 the levels of protein PB used linearly influence the rate of Seedor tibia (P <0.05), with linear response decreasing. The reduction in the levels of CP in the diet, results in lower values for the index of Seedor by reducing the length and weight of the femur. In general the reduction of 0%, 5%, 10% and 15% crude protein of diet on the recommended per phase, associated with correction of electrolyte balance, was not beneficial in the environmental conditions studied / Foram conduzidos quatro experimentos com o objetivo de avaliar os efeitos de diferentes balanços eletrolíticos e de teores de proteína bruta da ração para frangos de corte machos da linhagem Cobb criados em condições naturais de estresse calórico. No experimento 1 foram utilizadas 880 aves, no período de 1 a 7 dias de idade, com peso médio de 52 gramas. Sendo alojadas 22 aves por unidade experimental, comportando uma densidade de 14,10 aves.m-2 alojados em 40 boxes, distribuídos em delineamento inteiramente casualizados com 8 tratamentos, cinco repetições. No experimento 2, foram utilizadas 800 aves, no período de 8 a 21 dias de idade, com peso médio de 160 gramas. Sendo alojadas 20 aves por unidade experimental, comportando uma densidade de 12,82 aves.m-2. No experimento 3, foram utilizadas 640 aves, no período de 22 a 35 dias de idade com peso médio de 640 gramas. Sendo alojadas 16 aves por unidade experimental, comportando uma densidade de 10,25 aves.m-2. No experimento 4, foram utilizadas 480 aves, com peso médio de 1700 gramas, no período de 36 a 42 dias de idade. Sendo alojadas 12 aves por unidade experimental, comportando uma densidade de 7,69 aves.m-2. As rações foram formuladas a base de milho, farelo de soja e glútem de milho para atender as exigências nutricionais das aves, em todos os experimentos, segundo Rostagno et al. (2005), exceto para proteína bruta cujos níveis foram calculados, considerando os níveis recomendados reduzindo 5%, 10% e 15%, e dois balanços eletrolítico (200 e 240 mEq.kg-1) em todos os experimentos. Os animais receberam água e ração à vontade. Em todos os experimentos foi avaliado desempenho zootécnico (Ganho Médio de Peso, Consumo Médio de Ração, Peso Final e Conversão Alimentar), parâmetros sanguíneos (ácido úrico, proteína total, cálcio, sódio, potássio, cloro); e desenvolvimento ósseo (índice de Sedoor). As condições ambientais do galpão foram monitoradas seis vezes ao dia com auxilio de um termo higrômetro e um termômetro de globo negro e as leituras usadas para calculo do Índice de Temperatura de Globo Negro e Umidade (ITGU). Durante o período experimental, os valores de temperatura, umidade relativa, temperatura de globo negro e ITGU mantiveram-se acima da zona de termoneutralidade para frango de corte. Para as variáveis de desempenho, em todos os experimentos, exceto para o experimento 4, as aves obtiveram maior ganho de peso e peso final com o balanço de 240 mEq.kg-1. Em todos experimentos, as aves que receberam ração com redução dos níveis de PB apresentaram desempenho inferior em relação às alimentadas com ração sem redução protéica, independente do BE. Este resultado fica mais evidente na ração com redução de 15% de PB. Com relação às análises sanguínea, conforme se diminuía os níveis de PB na dieta, diminuía também a concentração de ácido úrico no soro (p<0,05). Para o balanço eletrolítico de 200 mEq.kg-1 verificou-se o maior valor de cálcio no soro sanguíneo. As aves obtiveram menores percentuais sangüíneos de proteína total com balanço na faixa de 240 mEq.kg-1, Os valores médios dos níveis de proteína total no sangue que variam de 2,36 (experimento 4) a 2,92 mg.dL-1 (experimento 2) e encontram-se abaixo de 3,6 mg.dL-1, considerados normais. As concentrações de K+, Cl- (Experimento 4), não foram influenciadas (p>0,05) pelos tratamentos. Em relação à concentração de sódio aos 21 dias de idade (Experimento 2), a redução da proteína bruta da ração diminuiu (p<0,05) as concentrações deste mineral no soro. Esta resposta, entretanto, não foi observada aos 42 dias de idade (Experimento 4). Para avaliação de desenvolvimento ósseo, somente os níveis de proteína PB utilizados no experimento 3, influenciaram linearmente o índice de Seedor do fêmur (P<0,05). O efeito dos níveis de PB sobre o índice de Seedor não foi significativo (P<0,05) para os demais experimentos. Para frangos de 22 a 35 dias de idade, os níveis de PB na ração provocaram efeito linear e decrescente no índice de Seedor do fêmur. Somente no experimento 1 os níveis de proteína PB utilizados influenciaram linearmente o índice de Seedor da tíbia (P<0,05), com resposta linear decrescente. A redução nos níveis de PB na dieta, implica em menores valores para o índice de Seedor, por diminuir o comprimento e peso do fêmur. De maneira geral a redução de 0%, 5%, 10% e 15% da proteína bruta da ração, em relação ao recomendado por fase, associada à correção do balanço eletrolítico, não se mostrou benéfica nas condições ambientais estudadas
318

Conforto térmico no Colégio de Aplicação Pedagógica da Universidade Estadual de Maringá: proposta para melhoria do desempenho térmico de um antigo CAIC / Thermal Comfort in the Pedagogical College of the State University of Maringá: proposal for improving the thermal performance of an old CAIC

Mariana Fortes Goulart 07 April 2014 (has links)
O Colégio de Aplicação Pedagógica da Universidade Estadual de Maringá (CAP/UEM) fazia parte de um projeto de âmbito nacional criado na década de 1990, os Centros de Atenção Integral à Criança e ao Adolescente - CAIC´s. O projeto inicial é de autoria do arquiteto João Filgueiras Lima, Lelé, reconhecido pela preocupação com o conforto ambiental dos usuários em suas obras. Em geral, sabe-se que os alunos têm uma melhor qualidade no aprendizado quando os espaços estão bem ventilados, iluminados e silenciosos. Sendo assim, este trabalho tem como objetivo avaliar o conforto térmico no edifício do CAP/UEM verificando o desempenho das estratégias passivas para proporcionar conforto térmico, a sensação térmica dos usuários e aferindo o desempenho de uma estratégia, sugerida pelo arquiteto Lelé em entrevista a autora, para melhoria do comportamento térmico da cobertura. A metodologia proposta consiste, inicialmente, em um levantamento de dados que se destaca pela entrevista com o arquiteto. Após, foi feita uma análise projetual para a identificação e caracterização das soluções passivas de conforto e a verificação do funcionamento destas no âmbito de projeto. Para verificar a eficiência destas estratégias foi aplicado o método dos Votos Médios Preditos (PMV), que envolve medições das variáveis ambientais concomitantemente com aplicação de questionários aos alunos no período de verão. Além disso, ainda foi avaliado o desempenho térmico da cobertura, através de medições de temperaturas superficiais internas e externas comparadas entre três salas de aula: uma inalterada, outra lavada e a terceira, lavada e pintada de branco, sugestão do arquiteto Lelé para melhorar o desempenho térmico do edifício. Os resultados indicaram que a cobertura do prédio ocasiona grande ganho térmico e insatisfação dos usuários praticamente o tempo todo, prejudicando as condições de conforto no interior do edifício. Esse alto grau de desconforto pode ser explicado pela falta de manutenção e a pouca inércia térmica do sistema, principalmente da cobertura. A pintura do telhado de branco se mostrou eficiente para diminuir o calor que entra pela cobertura, ressaltando a importância da temperatura radiante para promoção das condições de conforto térmico nas salas de aula. / The Pedagogical College of the State University of Maringá (CAP/UEM) was part of a nationwide project created in the 1990s, the Centres for the Integral Care to Children and Adolescents - CAIC\'s. The initial design was concived by the architect João Filgueiras Lima (a.k.a. Lelé), acknowledged for his concern for the environmental comfort of users in his work. In general, it is known that the students have a better quality of learning when the spaces are well chilled, lighted and quiet. Therefore, this study aims to evaluate the thermal comfort in the building of the CAP/UEM checking the performance of passive strategies of thermal comfort, thermal sensation of users and verifying the performance of a strategy, suggested by the architect Lelé in an interview for the author, to improve the thermal performance of the roof. The proposed methodology consists, initially, in a collection of the datas that stands out from the interview with the architect. Afterwards, it was made an analysis projectual in order to identify passive solutions to obtain thermal comfort, at the same time, to verify the work system of this project. To check the efficiency of these strategies it was apllied the Predicted Mean Vote Method (PMV), that envolve measurements of environmental variables concurrently with questionnaires applied to students during the summer time. Futher there, it was analized the thermal performance of the roof, throught out indoor and outdoor superficial temperature measurements, compared between three classrooms: one untouchable, another washed and the third one washed and white painted, suggested by the architect Lelé to improve thermal comfort of the building. The results indicate that the roof of the building causes huge thermal gain and unsatisfaction of the users all the time, damaging the comfort conditions within the building. This high level of uncomfortable can be explained by the lack of maintenance and the low thermal inertia of the system, especially the roof. The white paint of the roof has shown efficient to reduce the heating coming throughout the roof, highlighting the importance of radiant temperature for promotion of thermal comfort conditions in classrooms.
319

O conforto térmico associado às variáveis de cobertura da terra na região central de Juiz de Fora – MG

Assis, Débora Couto de 20 May 2016 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-01-16T14:15:12Z No. of bitstreams: 1 deboracoutodeassis.pdf: 17927369 bytes, checksum: 90ae6fe51982bf87627a6d93e3fe6ef1 (MD5) / Approved for entry into archive by Diamantino Mayra (mayra.diamantino@ufjf.edu.br) on 2017-01-31T10:34:36Z (GMT) No. of bitstreams: 1 deboracoutodeassis.pdf: 17927369 bytes, checksum: 90ae6fe51982bf87627a6d93e3fe6ef1 (MD5) / Made available in DSpace on 2017-01-31T10:34:36Z (GMT). No. of bitstreams: 1 deboracoutodeassis.pdf: 17927369 bytes, checksum: 90ae6fe51982bf87627a6d93e3fe6ef1 (MD5) Previous issue date: 2016-05-20 / FAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais / A atual dinâmica de urbanização resulta no avanço de ambientes antropizados sobre o meio natural, que produz um clima essencialmente urbano, o qual se caracteriza por desequilíbrios que podem ser prejudiciais ao conforto humano e até mesmo à saúde. Neste sentido faz-se necessário, portanto, estudos que avaliem as condições térmicas deste ambiente modificado, além da investigação dos responsáveis por estas alterações. Igualmente é salutar o desenvolvimento de métodos capazes não só de mapear, mas de compreender os padrões espaciais geradores destas zonas de conforto diferenciadas. Sendo assim, o objetivo desta pesquisa é identificar padrões e processos relacionados ao uso da terra, aos fatores climáticos e ao crescimento e adensamento urbano, enquanto contribuição para a formação de zonas de conforto, estipuladas pelo Índice de Temperatura Efetiva em função do vento (TEv). Por fim, este trabalho também objetiva fornecer subsídios ao planejamento urbano/ambiental da cidade. A investigação se deu na região central de Juiz de Fora, que engloba 12 regiões urbanas, as quais tiveram tratamento de dados coletados em campo com a instalação de estações meteorológicas em pontos previamente escolhidos, durante o período dos dias 11 a 23 de Agosto de 2015. Quanto aos dados secundários, estes foram trabalhados através de ferramentas de Geoprocessamento. Como resultado constatou-se diferentes zonas de conforto térmico na Região Central, atreladas às distintas condições de adensamento, denotando áreas sombreadas, o que pôde gerar atenuação na temperatura, além do vento, o qual possuiu uma função determinante nas condições de conforto e até mesmo desconforto. / The current dynamics of urbanization results in advance of anthropogenic environments on the natural environment, which produces an essentially urban climate, which is characterized by imbalances that can be harmful to human comfort and even health. Thus, it is necessary, therefore, studies to evaluate the thermal conditions of this changed environment, besides to the investigation of those responsible for these changes. It also is beneficial to develop methods able not only to map, but to understand the generating spatial patterns of these different comfort zones. Thus, the objective of this research is to identify patterns and processes related to the use of land, climatic factors and growth and urban density, as a contribution to the formation of comfort zones, stipulated by Effective Temperature Index in wind function (TEv ). Finally, this work also aims to provide subsidies to the urban / environmental planning of the city. The research took place in the central region of Juiz de Fora, which covers 12 urban areas, which had processing of data collected in the field and secondary data through GIS tools. As a result it was found different areas of thermal comfort in the Central Region, linked to conditions of densification, showing shaded areas, which could generate attenuation in temperature, but the wind, which owned a decisive role in comfortable conditions and even discomfort.
320

Avaliação do sistema de ventilação em instalações para frangos de corte através de diferentes modelagens / Different methodologies to evaluate ventilation systems in broiler facilities

Carvalho Curi, Thayla Morandi Ridolfi de, 1985- 25 August 2018 (has links)
Orientadores: Daniella Jorge de Moura, Danilo Florentino Pereira / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agrícola / Made available in DSpace on 2018-08-25T02:19:47Z (GMT). No. of bitstreams: 1 CarvalhoCuri_ThaylaMorandiRidolfide_D.pdf: 8328770 bytes, checksum: eebd78d76f94cf27d5dfc9f66ccc7938 (MD5) Previous issue date: 2014 / Resumo: Na avicultura, com o recente aumento no número de aviários climatizados, projetar e adequar instalações ao clima quente que permitam a manutenção da temperatura, umidade relativa, velocidade do ar, concentração de amônia e dióxido de carbono em limites ideais às exigências das aves, sem aumento dos custos de produção, tem sido um grande desafio. Neste contexto, o objetivo deste trabalho foi avaliar o sistema de ventilação em quatro diferentes tipologias de aviários para frangos de corte em relação à qualidade do ambiente por meio de técnicas computacionais de simulação, tais como, Computational Fluid Dynamics, geoestatística e redes neurais e posicionamento estratégico de sensores. Para isso, o trabalho foi conduzido em quatro instalações de frangos de corte localizados na região de Campinas com sistema de ventilação artificial e diferentes tipologias. Os sistemas de ventilação avaliados foram: BH - isolamento lateral por cortinas azuis e sistema de ventilação artificial de pressão negativa com exaustores; DH - isolamento lateral por cortinas pretas e sistema de ventilação mecanizada com exaustores e entrada de ar através do painel evaporativo; SW - isolamento lateral por paredes de alvenaria e sistema de ventilação artificial de pressão negativa com exaustores e entrada de ar através do painel evaporativo; e DWH - isolamento lateral por cortinas pretas e sistema de ventilação artificial de pressão negativa com exaustores e entrada de ar através do painel evaporativo (DWH). Foram monitoradas as variáveis climáticas (temperatura, umidade relativa e velocidade do ar) e o ambiente aéreo (concentração de dióxido de carbono e amônia) duas vezes ao dia (9h00min e 14h00min), semanalmente aos 21, 28, 35 e 42 dias de idade das aves, em 52 pontos equidistantes na altura das mesmas, no período de inverno e verão. Os dados foram analisados por meio da análise estatística, geoestatística, redes neurais e CFD no intuito de avaliar, entender e sugerir mudanças para o sistema de ventilação. A partir das análises realizadas no presente trabalho foi possível observar que o período de verão é o mais crítico para criação de aves na fase final de criação. A análise geoestatística mostrou que a presença ou não do painel evaporativo influencia na condição padrão de funcionamento do sistema de ventilação. O painel evaporativo auxilia no resfriamento do ar no centro do aviário, enquanto nas paredes laterais ocorrem temperaturas acima do recomendado pela literatura em instalações com largura menores que 20 m. Aviários com largura maiores que 20 m apresentam regiões com baixa renovação de ar nas laterais e em todo o comprimento. A melhor disposição dos sensores (de temperatura e umidade) no interior do aviário foi três pontos equidistantes. A técnica do CFD permitiu visualizar o encaminhamento do ar de acordo com as diferentes condições de funcionamento dos exaustores em 2D e 3D e, determinar o melhor arranjo para o acionamento de exaustores a fim de evitar a formação de regiões com baixa renovação do ar e zonas de turbulência. As redes neurais artificiais foram capazes de auxiliar a tomada de decisão quanto da vazão de ar dos exaustores necessária para renovação e resfriamento do ar nas instalações de frango de corte / Abstract: With the recent increase in the acclimatized broiler houses in Brazil, the design and adaptation to the hot climate condition allowing the maintenance of the ideal temperature, relative humidity, air velocity, ammonia and carbon dioxide concentration has been a major challenge. The aim of this study was to evaluate the ventilation system in four different broiler houses typology in relation to air quality and thermal environment using computational techniques such as: computational fluid dynamics (CFD), geostatistics and neural networking. The research was carried out in four facilities located in Campinas region. Each facility had a different acclimatization system. The acclimatization system evaluated were: BH ¿ side wall curtains and exhaust fans in negative pressure ventilation system, DH ¿ side wall curtains and exhaust fans in negative pressure ventilation system with evaporative cooling panel, DWH ¿ side wall curtains and exhaust fans in negative pressure ventilation system with evaporative cooling panel and SW ¿ concrete bricks wall and exhaust fans in negative pressure ventilation system with evaporative cooling panel. The following climates were evaluated twice a day 9 AM and 2PM: temperature, relative humidity, air velocity, carbon dioxide and ammonia concentration when the birds were aged 21, 28, 35 and 42 days old. The data were monitored in 52 equidistant points, in the height of the birds, in summer and winter time. Data were evaluated by statistics analysis, geostatistic, neural networking and CFD in order to assess, understand and suggesting changes to the ventilation systems. The results showed that summer time is the more critical for final phase. Geostatistical analysis demonstrated the presence or absence of the evaporative panel influences the pattern of air flow. The ventilation systems with pad cooling chilled the air in the center of the building while the side walls active temperature above the temperature recommended in facilities with less than 20 m wide. However, poultry facilities greater than 20 m wide presents regions with lower air exchange, especially nearby side walls. The best position to locate the temperature and relative humidity sensors was in three equidistant points. The CFD technique allowed to visualize the air flow in 2D and 3D according to the different working conditions for the exhaust fans and, as well as determined the best exhaust fans arrangement to work avoiding low air exchange or turbulence area. The artificial neural networking was able to assist the decision making regards the ideal the air flow from the exhaust fans required to air exchanged and air cooling in the broiler house / Doutorado / Construções Rurais e Ambiencia / Doutora em Engenharia Agrícola

Page generated in 0.1553 seconds