• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 307
  • 107
  • 34
  • 21
  • 20
  • 10
  • 8
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 583
  • 583
  • 315
  • 294
  • 125
  • 89
  • 80
  • 76
  • 70
  • 68
  • 64
  • 64
  • 60
  • 58
  • 54
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
411

Evaluating the Effectiveness of Tree Locations and Arrangements for Improving Urban Thermal Environment

January 2017 (has links)
abstract: Trees serve as a natural umbrella to mitigate insolation absorbed by features of the urban environment, especially building structures and pavements. For a desert community, trees are a particularly valuable asset because they contribute to energy conservation efforts, improve home values, allow for cost savings, and promote enhanced health and well-being. The main obstacle in creating a sustainable urban community in a desert city with trees is the scarceness and cost of irrigation water. Thus, strategically located and arranged desert trees with the fewest tree numbers possible potentially translate into significant energy, water and long-term cost savings as well as conservation, economic, and health benefits. The objective of this dissertation is to achieve this research goal with integrated methods from both theoretical and empirical perspectives. This dissertation includes three main parts. The first part proposes a spatial optimization method to optimize the tree locations with the objective to maximize shade coverage on building facades and open structures and minimize shade coverage on building rooftops in a 3-dimensional environment. Second, an outdoor urban physical scale model with field measurement is presented to understand the cooling and locational benefits of tree shade. The third part implements a microclimate numerical simulation model to analyze how the specific tree locations and arrangements influence outdoor microclimates and improve human thermal comfort. These three parts of the dissertation attempt to fill the research gap of how to strategically locate trees at the building to neighborhood scale, and quantifying the impact of such arrangements. Results highlight the significance of arranging residential shade trees across different geographical scales. In both the building and neighborhood scales, research results recommend that trees should be arranged in the central part of the building south front yard. More cooling benefits are provided to the building structures and outdoor microclimates with a cluster tree arrangement without canopy overlap; however, if residents are interested in creating a better outdoor thermal environment, open space between trees is needed to enhance the wind environment for better human thermal comfort. Considering the rapid urbanization process, limited water resources supply, and the severe heat stress in the urban areas, judicious design and planning of trees is of increasing importance for improving the life quality and sustaining the urban environment. / Dissertation/Thesis / Doctoral Dissertation Geography 2017
412

Qualidade dos espaços públicos viários: ergonomia em escala urbana

Gasparini Júnior, Roberto Antônio [UNESP] 20 July 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-07-20Bitstream added on 2014-06-13T18:51:47Z : No. of bitstreams: 1 gasparinijunior_ra_me_bauru.pdf: 1653529 bytes, checksum: 06b355dfab100d5f0587b736af461a59 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O trabalho analisa o espaço público sob aspectos que envolvem a ergonomia em escala urbana por meio de avaliação pós-ocupação com ênfase em parâmetros comportamentais e de conforto térmico. A pesquisa estuda as condições microclimáticas e morfológicas, relacionando-as com a quantidade e a qualidade de uso para conhecer as influências dessas variáveis no comportamento dos usuários. Para isso, utilizou-se como estudo de caso três vias de Bauru, SP, espaços públicos de grande importância para a cidade, que apresentam diferentes aspectos e diversos tipos de uso. Utilizou-se uma metodologia adaptada que considerou dados quantitativos e também qualitativos, fazendo-se uso também de entrevistas para se conhecer o perfil do usuário e seu grau de satisfação. Os resultados evidenciam a relação entre uso e microclima, bem como entre o uso e outras características peculiares de cada espaço, identificando aspectos positivos e negativos. Objetivou-se também, contribuir com dados que subsidiem intervenções projetuais nos espaços analisados ou em áreas similares. Assim, mostrou-se que o profissional de planejamento deve dedicar especial atenção ao comportamento microclimático gerado com a morfologia como determinantes da qualidade do uso, em garantia do sucesso do espaço público / This work analyses the public space under some aspects of ergonomy in urban scale by post-occupation evaluation system based on user’s behavior and thermal comfort. The research studies the microclimate and morphological conditions, doing relations with the quantity and quality of the uses to know the influences of these variables on users’ behaviors. Then were studied three roads in Bauru, SP, public spaces with great importance for the city, which presents different aspects and various kind of use. An adapted methodology was used to consider quantitative data and also the qualitative ones, doing interviews to know the users’ profile and your opinion about the place. The results showed a relationship between use and microclimate, as well as between use and other characteristics of each space, identifying positives and negatives aspects. This study also means to contribute with data to provide information for intervention at the studied spaces or similar areas. Then, the planner must dedicate special attention to the microclimate behavior produced by the morphology like important motive of quality use in this way guarantee the success of the public space
413

Avaliação de parâmetros cardiovasculares e desempenho cognitivo de estudantes de ambientes inteligentes de ensino submetidos à variação de temperatura do ar

Siqueira, Joseana Celiza Fernandes 24 February 2015 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2016-04-19T14:30:40Z No. of bitstreams: 1 arquivo total.pdf: 5424467 bytes, checksum: 801d02752f22cdbc2f419432ff437a77 (MD5) / Made available in DSpace on 2016-04-19T14:30:40Z (GMT). No. of bitstreams: 1 arquivo total.pdf: 5424467 bytes, checksum: 801d02752f22cdbc2f419432ff437a77 (MD5) Previous issue date: 2015-02-24 / Several institutions have issued alerts about the rise in global temperature in the past few years, and on its tendency to keep rising in the future. This temperature rise has been associated to human deaths, some of which related to cardiovascular dysfunctions, and to loss of physical and cognitive performance on humans. Purpose: To analyze the relation between cardiovascular parameters (blood pressure and heart rate) and cognitive performance of students submitted to changes of temperature in classrooms. Methods: The university students answered the survey adapted of Battery of Reasoning Tests (BPR-5) during three consecutive days in different temperatures, while thermal conditions and heart rate were measured. In these days, the blood pressure and the heart rate were evaluated before and after the test. Results: The blood pressure did not alter with different temperatures during cognitive activity. However, the average heart rate and the final increased at high temperatures. The accuracy of cognitive performance was not altered with changes of temperature, on the other hand, the execution time reduced at high temperatures. Using the analyzes by Generalized Linear Models, it was observed that the accuracy on cognitive test was related to mean blood pressure at the beginning of the test, the maximum heart rate during the test and the air temperature. Conclusion: This research concluded that accuracy in cognitive performance rises from 70% to 75%.when the students are submitted to temperatures which them consider neutral and maximum heart rate and mean blood pressure are compatible with activity. / Diversos institutos têm alertado sobre o aumento da temperatura do ar global nos últimos anos e a sua tendência em continuar aumentando. Este aumento tem sido associado a perda da produtividade física e cognitiva e a mortes humanas, algumas vezes relacionadas a disfunções cardiovasculares. Objetivo: Analisar a relação entre os parâmetros cardiovasculares (frequência cardíaca e pressão arterial) e o desempenho cognitivo de alunos submetidos à variação de temperatura do ar em ambientes de ensino. Métodos: Alunos universitários responderam a um questionário adaptado da Bateria de Provas de Raciocínio (BPR-5) em três dias consecutivos a diferentes temperaturas, enquanto as condições térmicas e frequência cardíaca foram medidas. Nestes dias, a pressão arterial e a frequência cardíaca foram avaliadas antes e depois do questionário. Resultados: A pressão arterial não foi alterada pela temperatura durante a realização de atividade cognitiva. Entretanto, tanto a frequência cardíaca média quanto a final aumentaram com o aumento da temperatura. Quanto ao desempenho, a acurácia do teste cognitivo não foi afetada pelas mudanças da temperatura. Por outro lado, houve redução no tempo de execução a altas temperaturas. Utilizando Modelos Lineares Generalizados foi observado que a acurácia no teste cognitivo foi relacionado à pressão arterial média ao início do teste, a frequência cardíaca máxima durante a atividade e a temperatura do ar. Conclusão: Esta pesquisa concluiu que a acurácia do desempenho cognitivo se eleva de 70% para 75% quando os alunos estão submetidos à temperatura que consideram neutra e com frequência cardíaca máxima e pressão arterial média adequadas para a atividade executada
414

Mapeamento e análise espacial do ambiente térmico de aviários de postura abertos em sistemas verticais / Mapping and spatial analysis of the thermal environment of open laying hens housing in vertical system

Coelho, Diogo José de Rezende 21 February 2014 (has links)
Made available in DSpace on 2015-03-26T13:24:00Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1723171 bytes, checksum: 7eb23327b84ea3efaee3e770c680bcc8 (MD5) Previous issue date: 2014-02-21 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In the current poultry industry, advances in the areas of nutrition, genetics, management and animal health, along with the importance now being given to the ambiance of the bird to its range of thermal comfort, the activity is allowed to consolidate as one of the most important agricultural sector. The production environment does a fundamental role in the success or failure of the activity, and environmental factors such as temperature and relative humidity are those that most directly affect the birds, because compromise their most important baseline function, which is to maintain of homeothermic own. Thus, the birds require values of temperature and relative humidity of the environmental air within certain specific ranges, and out of this comfort zone, have compromised their performance. The objective of this work was to realize the full thermal mapping of typical barns for layers practiced in Brazil, vertical rearing systems, and to establish the most representative spatial position of the average conditions of temperature and relative humidity of the air inside the housing for better positioning the sensors command of air conditioners panels. The study was conducted in Itanhandu, in Minas Gerais State - Brazil, in a commercial laying hens barn, with the typical patterns used barn creation practiced in Brazil, called vertical systems, during the peak egg production. The barn is 100% automated, having 100,000 birds / barn, housed in four batteries with six levels of cages. The results were presented in two articles: Article I - Mapping the thermal environment of open aviaries in vertical position for the phase of peak egg production system; Article II - Determination of representative spatial position of the average temperature and relative humidity for layer hens in vertical rearing systems. Through the results of the survey, one can observe a thermal variability within the aviary, with the central region had higher temperatures of the extremities, and in situations of maximum temperatures occurrence of heat stress in birds. It was also possible to determine the best allocation for spatial positioning of the temperature sensors and humidity within the facility, and that they represent the internal thermal conditions are distant extremities of the aviary at 1⁄4 the length of the installation, and also away from the sides of barn, so as to be positioned in the intermediate runners, the average height of the battery cages. / Na avicultura atual, os avanços nas áreas da nutrição, genética, manejo e sanidade animal, juntamente com a importância que passou a ser dada à ambientação da ave à sua faixa de conforto térmico, permitiram que a atividade se consolidasse como uma das mais importantes do setor agropecuário. O ambiente de produção desempenha papel fundamental para o sucesso ou fracasso da atividade, sendo que fatores ambientais tais como, temperatura e umidade relativa do ar são os que afetam mais diretamente as aves, pois comprometem a sua função basal mais importante, que é a manutenção da própria homeotermia. Sendo assim, as aves necessitam de valores de temperatura e umidade relativa do ar ambiente dentro de certas faixas específicas e, fora desta zona de conforto, tem seu desempenho comprometido. Objetivou-se com este trabalho realizar o mapeamento térmico completo de aviário de postura típico dos padrões praticados no Brasil, sistemas verticais de criação, bem como estabelecer a posição espacial mais representativa das condições médias de temperatura e umidade relativa do ar interna do alojamento para melhor posicionamento dos sensores de comando dos painéis climatizadores. O trabalho foi desenvolvido no município de Itanhandu - Minas Gerais, em uma granja comercial de aves de postura, sendo o aviário utilizado típico dos padrões de criação praticados no Brasil, denominados sistemas verticais, durante a fase de pico de postura das aves. O aviário é 100% automatizado, possuindo 100.000 aves/aviário, alojadas em quatro baterias com seis andares de gaiolas. Os resultados obtidos foram apresentados em dois artigos: Artigo I - Mapeamento do ambiente térmico de aviários de postura abertos em sistema vertical para a fase de pico de postura das aves; Artigo II - Determinação da posição espacial representativa das condições médias de temperatura e umidade relativa do ar para aviários de postura em sistemas verticais de criação. Por meio dos resultados da pesquisa realizada, pode-se observar uma variabilidade térmica dentro do aviário, com a região central apresentando temperaturas superiores as das extremidades, e nas situações de temperaturas máximas ocorrência de estresse calórico das aves. Foi possível também determinar que os melhores posicionamentos espaciais para alocação dos sensores de temperatura e umidade dentro da instalação, e que estes representassem as condições térmicas internas, são distantes das extremidades do aviário, à 1⁄4 o comprimento da instalação, e também afastadas das laterais do aviário, de modo a ser posicionado nos corredores intermediários, na altura média da bateria de gaiolas.
415

Estudo do comportamento de materiais não convencionais utilizados como revestimento de paredes, visando à redução da carga térmica.

Sousa, Vívian Aparecida Lima 10 February 2012 (has links)
Made available in DSpace on 2015-05-08T14:53:20Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2371434 bytes, checksum: 9feb77190f039aa7f22992e3cc4e4ad9 (MD5) Previous issue date: 2012-02-10 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This dissertation studied the behavior thermal, physical and mechanical of mortar coatings composed of pure gypsum, plaster / EVA (ethylene-vinyl acetate copolymer) and gypsum / vermiculite applied on surfaces of building walls in order to reduce the thermal load on the walls consisted of conventional ceramic bricks and cement-sand mortar, taken as a reference. The objective was to obtain a material capable of reducing the thermal load and therefore the consumption of electrical energy used in air conditioning system for the thermal comfort of people and protection of equipment from the electrical substation of CHESF located in Milagres, in the semi-arid northeast of Brazil. The mortars were developed at the Laboratory for Testing Materials and Structures LABEME / UFPB, and underwent tests assessing their physical and mechanical properties. The result showed that the mortars have developed physical and mechanical properties that satisfy the standards in Brazil, being suitable the use of coating internal and external walls. Moreover, its application involves the reduction of non-degradable material released in nature, as the residue of EVA. The thermal conductivity of each mortar was obtained at the Laboratory of Porous Media and Thermophysical Properties LMPT UFSC-through flowmetric method. The mortar plaster, plaster / EVA and gypsum / vermiculite showed the thermal conductivity of 0.43 W / mK, 0.41 W / mK and 0.22 W / mK, respectively, behaving as thermal insulation. The results showed that the coating using mortar and plaster gypsum / EVA had a 18% reduction of thermal load of the environment on the wall by reference. And using the coating gypsum mortar / vermiculite this reduction reached 36%. / A presente dissertação estudou o compartamento térmico, físico e mecânico das argamassas de revestimentos compostas por gesso puro, gesso/EVA (ethylene-vinyl acetate copolymer) e gesso/vermiculita aplicadas nas superficies das paredes de edificação visando à redução da carga térmica relativamente às paredes convencionais constituídas de tijolos de cerâmica e argamassas de cimento-areia, tomadas como referência. O objetivo foi obter um material capaz de reduzir a carga térmica e, por conseguinte, o consumo da energia elétrica utilizada no sistema de ar condicionado para o conforto térmico das pessoas e a proteção dos equipamentos de uma subestação elétrica da CHESF localizada em Milagres, na região semi-arida do nordeste brasileiro. As argamassas foram desenvolvidas no Laboratório de Ensaio de Materiais e Estruturas LABEME/UFPB, onde foram submetidas a testes da avaliação de suas propriedades fisicas e mecânicas. O resultado mostrou que as argamassas desenvolvidas têm propriedades físicas e mecânicas que satisfazem às normas brasileiras, sendo adequedas ao uso de revestimento de paredes internos e externos. Além disso, sua aplicação implica a redução de material não degradável lançado na natureza, como o residuo de EVA. A condutividade térmica de cada argamassa foi obtida no Laboratório de Meios Porosos e Propriedades Termofisicas LMPT-UFSC, através do método fluxometrico. As argamassas de gesso, gesso/EVA e gesso/Vermiculita apresentaram as condutividades térmicas de 0,43 W/mK, 0,41 W/mK e 0,22 W/mK, respectivamente, comportando-se portando, como isolamentes térmicos. Os resultados mostraram que utilizando o revestimento da argamassa de gesso e de gesso/EVA tem-se uma redução de 18% de carga térmica do ambiente em relação à parede de referencia. E utilizando o revestimento da argamassa de gesso/vermiculita essa redução chega a 36% .
416

An?lise bioclim?tica e investiga??o do conforto t?rmico em ambientes externos: uma experi?ncia no bairro de Petr?polis em Natal/RN / Bioclimatic analysis and investigation of thermal comfort in open spaces: An experience in the district of Petr?polis in Natal/RN

Costa, Angelina Dias Le?o 07 July 2003 (has links)
Made available in DSpace on 2014-12-17T13:57:17Z (GMT). No. of bitstreams: 1 AngelinaDLC_ate_cap4.pdf: 1799769 bytes, checksum: 9759bc5a57f38b8075aa467bae6e7d0c (MD5) Previous issue date: 2003-07-07 / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico / This study was intended to investigate how the urban form has been influencing the changes in the climate of the city and make a correlation between the climate and the thermal sensation of the users of open spaces. The research was developed in the district of Petr?polis in Natal/ RN whose occupation has been almost consolidated. Among other reasons, this district was selected because it was planned considering the environmental aspects of comfort. The methodologies used are based on KATZSCHNER (1997) and OLIVEIRA (1988) studies, which suggest the drawing and analysis of maps of the area under study, including topography, height of the buildings, land use, green areas, and types of soil pavement, as well as measurement of the environmental variables: air temperature, relative humidity, direction and wind speed for a comparative study. As part of this, study local users of the district were interviewed about their thermal sensations in open spaces. For the statistical analysis, data was collected at 10 distinct points characterized by BUSTOS ROMERO (2002), being 8 within the district and 2 at different places (outside the district), at climatologic stations, in 3 periods (August/2000, January/2002 and June/2002), for 4 consecutive days for each measurement (from Sunday to Wednesday) at the time of lower and higher temperatures in the city, 6:00 am and 1:00 pm, respectively. At the same time interviews were carried out with users of the open spaces in the area, totaling 171 valid formularies. The urban form showed a rather leveled topography, great diversity of land use and height of the buildings, with the existence of an area mostly occupied with high buildings, very little green area and soil practically impermeable. The statistical analysis showed high temperature and humidity levels. The wind direction is predominantly Southeast with extremely variable speeds. When the data from this district is compared with the data from other areas in the city and its outskirt, it was observed that this district is hotter and less ventilated than the others; besides, most users said that they felt uncomfortable in the local environmental conditions. The results of the analysis generated a zoning for the district with recommendations for soil occupation. The profile of the user was defined regarding the thermal comfort, as well as some discussion about the comfort parameters, including the proposal of limiting areas of temperature and humidity for the thermal comfort in the open spaces / Este estudo pretendeu investigar a maneira como a forma urbana vem influenciando as altera??es no clima da cidade e correlacion?-la com a sensa??o t?rmica do usu?rio do ambiente externo. A pesquisa ambientou-se no bairro de Petr?polis em Natal/ RN, que tem sua ocupa??o em parte consolidada e foi escolhido, dentre outras raz?es, por ter sido planejado levando-se em considera??o aspectos ambientais de conforto. As metodologias adotadas baseiam-se nos estudos de KATZSCHNER (1997) e OLIVEIRA (1988) que sugerem a elabora??o e an?lise de mapas da ?rea de estudo como topografia, altura das edifica??es, uso do solo, ?reas verdes e tipo de recobrimento do solo, aliados ? medi??o de vari?veis ambientais: temperatura do ar e umidade relativa, a velocidade e a dire??o dos ventos, para compara??o; al?m de entrevistas sobre a sensa??o t?rmica dos usu?rios do ambiente externo. Para a an?lise estat?stica foram levantados dados em 10 pontos distintos, caracterizados segundo m?todo proposto por BUSTOS ROMERO (2002), sendo 08 dentro do bairro e 02 fora dele, em esta??es meteorol?gicas, durante 03 per?odos (agosto/ 2000, janeiro/ 2002 e junho/ 2002), por 04 dias seguidos em cada per?odo (de domingo a quarta-feira), nos hor?rios de menor e maior temperatura para a cidade, 06h e 13h respectivamente. Simultaneamente, foram realizadas entrevistas com os usu?rios do ambiente externo do bairro, totalizando 171 formul?rios v?lidos. A forma urbana encontrada apresentou topografia pouco acidentada, grande diversidade de uso do solo e de altura das edifica??es com exist?ncia de n?cleo verticalizado, muito pouca ?rea verde e terreno praticamente imperme?vel. A an?lise estat?stica evidenciou altas temperaturas e umidades, e dire??o predominante dos ventos Sudeste, com velocidade bastante vari?vel. Quando comparados aos dados de outras ?reas da cidade e arredores, verifica-se que o bairro ? mais quente e menos ventilado; al?m disso, a maioria dos usu?rios sentiu-se desconfort?vel com as condi??es ambientais locais. Os resultados das an?lises possibilitaram um zoneamento para o bairro aliado a diretrizes para ocupa??o do solo; foi tamb?m tra?ado o perfil do usu?rio em conforto t?rmico e, levantadas algumas discuss?es acerca de par?metros de conforto, inclusive com a proposi??o de faixas limites de temperatura e umidade relativa do ar para o conforto t?rmico no ambiente externo
417

An?lises de elementos arquitet?nicos de prote??o solar em edifica??es institucionais na cidade de Natal/RN Diretrizes projetuais

Leite, Juliano Silva de Vasconcelos 15 December 2003 (has links)
Made available in DSpace on 2014-12-17T13:57:23Z (GMT). No. of bitstreams: 1 JulianoSVL_capa_ate_secao4.pdf: 2920544 bytes, checksum: 1be7339037691ce93eaf62558becf297 (MD5) Previous issue date: 2003-12-15 / The present work concerns the use of shade elements as architectural elements to block sunlight in public buildings. In a city like Natal, (5o South) the incidence of sunrays in any type of design should be a constant concern for all the architects. Besides, this habit of avoiding insolation in the environment is not a common practice. Within this context, the present work has the objective to dig deep into the knowledge of solar control, studying some cases and verifying its function according to the orientation and the original design of the building, having in mind if the shade elements usually used in the region have achieved their purpose of providing protection against the incidence of direct sun rays. This study considers the position of the shade element (horizontal and vertical), the angle formed between them and the respective facades, and the local of the buildings in relation to their orientation during the summer, winter and equinox solstice. As supporting instruments the solar map of the city and the protractor, for measuring shade angles, were used. It was concluded that in all the cases studied, it was not possible to obtain the maximum use of the elements. It was verified that the best type of shade element (more efficient) for the city of Natal is the mixed type (horizontal and vertical) and that the vertical shade elements are more efficient in the early mornings and late afternoon. The horizontal shade elements are used more effective at midday. We intend to present the results of this study to the architects in the region in order to show them the correct ways of using the shade elements according to the possible orientation on the facade, as a supporting tool at the time of designing a project as well as a subsidy for further discussions on the elaboration of the new urban standards for the city of Natal/RN / O presente trabalho apresenta o uso de elementos arquitet?nicos como forma de prote??o aos raios solares em edif?cios p?blicos. Em uma cidade como Natal (5? sul), a incid?ncia dos raios solares em qualquer tipo de projeto deveria ser uma preocupa??o constante para todos os arquitetos. Entretanto, o h?bito de proteger a edifica??o da insola??o n?o ? uma pr?tica comum. Dentro deste contexto, esta pesquisa tem como objetivo se aprofundar no conhecimento do controle solar, estudando alguns casos e verificando sua funcionalidade de acordo com a orienta??o e seu desenho original, tendo em mente que os elementos de sombra geralmente usados na regi?o t?m o prop?sito de dar prote??o contra a incid?ncia direta aos raios solares. Este estudo considera a posi??o do protetor solar (horizontal e vertical), o ?ngulo formado entre eles e as respectivas fachadas, al?m do local da edifica??o em rela??o a sua orienta??o durante os solst?cios de ver?o e inverno e equin?cio. Como instrumento de apoio foram utilizadas as cartas solares para a cidade e o transferidor de ?ngulo de sombra. Conclui-se que em todos os casos estudados, n?o foi poss?vel obter m?ximo proveito destes elementos. Foi verificado que o melhor protetor solar (mais eficiente) para a cidade do Natal ? o do tipo misto (horizontal e vertical) e que os elementos verticais s?o mais eficientes no come?o da manh? e final da tarde. Os elementos horizontais s?o mais eficientes pr?ximos ao meio-dia. Pretende-se apresentar os resultados deste estudo aos arquitetos da cidade para indicar as formas corretas de uso de elementos de prote??o ao sol, de acordo com a possibilidade da orienta??o da fachada, como ferramenta de aux?lio ao projeto, como tamb?m, que esta pesquisa possa servir de subs?dio para futuras discuss?es na elabora??o do novo c?digo de obras para a cidade de Natal/RN
418

Estudo t?rmico e de materiais na constru??o de casas populares com blocos confeccionados a partir de um composto a base de cimento, gesso, eps e raspa de pneu

Silva, Andr? da Rocha 16 August 2010 (has links)
Made available in DSpace on 2014-12-17T14:58:01Z (GMT). No. of bitstreams: 1 AndreRS_DISSERT.pdf: 3053585 bytes, checksum: 50d506b11ef1b50e68a6f0ead473ecc8 (MD5) Previous issue date: 2010-08-16 / We built an experimental house on an UFRN?s land using blocks made by a composite consisting of cement, plaster, EPS, crushed rubber and sand. Several blocks were made from various compositions and we made preliminary tests of mechanical and thermal resistance, choosing the most appropriate proportion. PET bottles were used inside the block to provide thermal resistance. In this work, a second function was given to the bottles: to serve as a docking between the blocks, because the ends of the cylinders came out of each block on top as well as at the bottom, with the bottom cut, allowing to fit of the extremities of the upper cylinder of a block in the lower holes of the other one, which were formed by the cutting already mentioned. Minimum compression tests were performed according to ABNT standards for walls closing blocks (fence). With that house built, we did studies of thermal performance in order to ascertain conditions of comfort, checking external and internal temperatures in the walls and in the ambient, among other variables, such as wind speed and relative humidity. The resulting blocks provided adequate thermal insulation to the environment, where the walls presented differences up to 11.7 ?C between the outer and inner faces, getting the maximum temperature inside the house around 31 ?C, within the so-called thermal comfort zone for warm climates. At the end of the experiments it was evident the effectiveness of that construction in order to provide thermal comfort in the internal environment of the house, as well as we could confirm the viability of building houses from recyclable materials, reducing the constructive costs, becoming a suitable alternative for low- incoming families. Moreover, besides the low cost, the proposal represents an alternative use of various recyclable materials, therefore considered an ecological solution / Foi constru?da uma casa experimental em um terreno da UFRN a partir de blocos confeccionados com um comp?sito constitu?do de cimento, gesso, EPS, borracha triturada e areia. Foram confeccionados diversos blocos a partir de composi??es variadas e foram efetuados testes preliminares de resist?ncia mec?nica e t?rmica, escolhendo-se a propor??o mais apropriada. Foram utilizadas garrafas PET no interior dos blocos a fim de proporcionar resist?ncia t?rmica. Neste trabalho, uma segunda fun??o foi conferida ?s garrafas: a de servir de encaixe entre os blocos, pois as extremidades das garrafas sa?am de cada bloco tanto na parte superior, como tamb?m na inferior, sendo a extremidade inferior seccionada, permitindo o encaixe das extremidades superiores das garrafas de um bloco nos orif?cios inferiores de outro bloco, os quais foram formados pela sec??o acima mencionada. Foram realizados ensaios de compress?o m?nima segundo as normas da ABNT para blocos destinados ao fechamento de paredes (blocos de veda??o). Constru?da a referida casa, foram realizados estudos de desempenho t?rmico a fim de averiguar as condi??es de conforto, verificando-se as temperaturas externa e interna nas paredes e a temperatura ambiente, dentre outras vari?veis, tais como a velocidade do vento e a umidade relativa do ar. Os blocos confeccionados proporcionaram isolamento t?rmico adequado para o ambiente, apresentando as paredes diferen?as de at? 11,7? C entre as faces externa e interna, ficando a temperatura m?xima interna da casa em torno de 31?C, dentro da chamada zona de conforto t?rmico para regi?es de clima quente. Ao t?rmino dos experimentos, ficou evidente a efic?cia da constru??o no sentido de proporcionar conforto t?rmino no ambiente interno da casa, bem como foi confirmada a viabilidade da constru??o de casas populares a partir de materiais recicl?veis, reduzindo-se o custo construtivo, sendo uma alternativa apropriada para fam?lias de baixa renda. Ademais, al?m do baixo custo, a proposta representa uma alternativa para o aproveitamento de diversos materiais recicl?veis, sendo ecologicamente correta
419

Efeito da temperatura e umidade na ingestão de alimentos de touros nelore confinados no cerrado

Oliveira, Tais Ferreira de 05 February 2016 (has links)
Neste estudo, objetivou-se analisar a influência da temperatura e umidade do ar sobre a ingestão de matéria natural de touros confinados no bioma cerrado. Foram utilizados 53 touros da raça Nelore monitorados individualmente pelo sistema GrowSafe System® de 12 de maio a 12 de agosto de 2014. A dieta foi composta por silagem de milho, milho grão moído, farelo de soja, ureia e núcleo mineral. A temperatura ambiente e umidade do ar foram registradas a cada hora por meio de Data Logger, e calculou-se o Índice de Temperatura e Umidade (ITU). Os dias foram divididos em quatro períodos (8- 10h; 10-15h; 15-18h e 18-8h) de acordo com a oferta da dieta no cocho (8, 10 e 15 horas) e calculou-se a média do consumo de matéria natural por horário por animal. As médias de consumo de matéria natural nos diferentes horários foram comparadas pelo teste tstudent. Utilizou-se regressão múltipla pelo método de Stepwise para relacionar o consumo médio com os fatores do ambiente térmico. Houve maior consumo de matéria natural no período mais ameno, das 18 às 8 horas, sendo, portanto, superior aos demais horários. Observou-se que o modelo que melhor explicou a relação entre consumo e ambiente térmico foi o que incluiu as variáveis independentes temperatura do ar, umidade relativa e ITU, conjuntamente. Os coeficientes padronizados para umidade; umidade e ITU; e umidade, ITU e temperatura apresentaram valores negativos. O ganho de massa corporal médio foi de 1,99 kg por dia de confinamento. Para cada segundo de permanência no cocho, o consumo aumentou em 3,20 gramas. Conclui-se que a temperatura e umidade, bem como em conjunto, calculadas no ITU podem reduzir o consumo de matéria natural de touros da raça Nelore em sistema de confinamento bem como o consumo de matéria natural está intimamente relacionado às horas de maior conforto térmico, observado no final da tarde e durante a noite. / In this study, was analysed the influence of air temperature and humidity on the natural matter feed intake of confined bulls in the cerrado biome. Fifty-three Nelore bulls were individually monitored by the GrowSafe System® from May 12 to August 12, 2014. The diet was composed by corn silage, ground corn, soybean meal, urea and mineral nucleus. The ambient temperature and air humidity were recorded every hour using Data Logger, and the Temperature and Humidity Index (THI) was calculated. The days were divided into four periods (8-10 h, 10-15 h, 15-18 h and 18-8 h) according to the meal offer in the trough (at 8, 10 and 15 h) and so on was calculated the mean of natural matter feed intake per hour per animal. The means of natural matter consumption at different times were compared by Student t test. Multiple regression was used by Stepwise method to relate the mean consumption with the thermal environment factors. There was greater consumption of natural matter in the milder period, from 18 to 8 hours, being, therefore, superior to the other periods. The model that best explained the relation between consumption and thermal environment which include the independent variables air temperature, relative humidity and ITU, together. The standardized coefficients for humidity; THI and humidity; THI and temperature presented negative values. The mean of body mass gain was 1.99 kg per day of confinement. For each second of permanency in the trough, consumption increased by 3.20 grams. It is concluded that the temperature; humidity, and both, calculated in the ITU can reduce the consumption of natural matter of Nelore bulls in confinement system as well as the natural matter feed intake is closely related to the hours of greater thermal comfort, that was observed in the late afternoon and at night. / Dissertação (Mestrado)
420

Estudos de sistemas de aquecimento aplicado a galpões avícolas com uso de elementos finitos

Leva, Flavia Fernandes de 23 November 2010 (has links)
The aim of this research was to evaluate and compare the behavior of temperature inside poultry sheds with bell jar type gas conventional heating and heating in the floor with use of a heat exchanger. It was used the public domain program FEMM 4.2 for the analysis of temperature through the use of finite elements techniques with data collected from two lots. Heating in the floor is made with the hot water flowing through a heat exchanger, which is installed below the bed; this hot water is from solar heaters. From the results obtained with the simulations can be observed that the heating through the floor provides a more homogeneous distribution breast when compared with the bell jar type heating. The flow of heat is upwards supplying thus the most needed heating of the bird that is the pectoral part. Energy consumption evaluation was made with use of LPG; this has enabled a comparative analysis of the quantity of electric energy necessary to provide the same thermal energy and the financial expenses obtained with the heating though LPG or electric energy for each lot. / Essa pesquisa foi conduzida com o objetivo de avaliar e comparar o comportamento da temperatura dentro do galpão avícola com aquecimento convencional tipo campânula a gás com o aquecimento pelo piso com o uso de serpentina. Foi utilizado para a análise do comportamento da temperatura o programa de computador de domínio público FEMM 4.2 que utiliza técnicas de elementos finitos, com base em 2 dos lotes coletados. O aquecimento pelo piso se dá com a utilização de água quente passando por um sistema tipo serpentina, que é instalada abaixo da cama, essa água quente é proveniente de aquecedor solar. A partir dos resultados obtidos com as simulações nota-se que o aquecimento através do piso fornece uma distribuição mais homogênea da temperatura quando comparado com o aquecimento tipo campânula. O fluxo de calor se dá de baixo para cima suprindo assim a necessidade maior de aquecimento da ave que é na parte peitoral. Foi realizada uma avaliação do consumo energético com a utilização do GLP, o que possibilitou uma análise comparativa da quantidade de energia elétrica necessária para fornecer a mesma energia térmica e os gastos financeiros obtidos com o aquecimento via GLP ou energia elétrica para cada lote. / Doutor em Ciências

Page generated in 0.1306 seconds