• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 171
  • 110
  • 31
  • 18
  • 14
  • 14
  • 14
  • 13
  • 11
  • 9
  • 5
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 420
  • 420
  • 106
  • 75
  • 69
  • 67
  • 60
  • 59
  • 50
  • 45
  • 43
  • 39
  • 37
  • 37
  • 36
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
371

Investigação da resistência a corrosão da liga Ti-13Nb-13Zr por meio de técnicas eletroquímicas e de análise de superfície

ASSIS, SERGIO L. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:29Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:10Z (GMT). No. of bitstreams: 1 11326.pdf: 1707325 bytes, checksum: f4b793f522e5d69e25de853d166b1c79 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
372

Microestrutura do metal de solda GTAW reforçado com carbonetos de titânio, parcialmente refundido por laser Nd:YAG pulsado / Microstructure of GTAW weld metal reinforced with titanium carbides, partially melted Nd:YAG laser pulsed

Pontin, Gabriel Inácio [UNESP] 28 July 2017 (has links)
Submitted by GABRIEL INÁCIO PONTIN null (gabrielguaira@hotmail.com) on 2017-08-15T18:00:10Z No. of bitstreams: 1 Dissertação Final - Gabriel Inacio Pontin.pdf: 2725651 bytes, checksum: f1433687bb33e3c16dd042c87cb686db (MD5) / Approved for entry into archive by Monique Sasaki (sayumi_sasaki@hotmail.com) on 2017-08-22T17:44:39Z (GMT) No. of bitstreams: 1 pontin_gi_me_ilha.pdf: 2725651 bytes, checksum: f1433687bb33e3c16dd042c87cb686db (MD5) / Made available in DSpace on 2017-08-22T17:44:39Z (GMT). No. of bitstreams: 1 pontin_gi_me_ilha.pdf: 2725651 bytes, checksum: f1433687bb33e3c16dd042c87cb686db (MD5) Previous issue date: 2017-07-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O desgaste abrasivo é uma das causas de falhas em equipamentos e responsável por prejuízos nos processos industriais. Uma técnica capaz de minimizar os efeitos deste fenômeno é a aplicação de revestimentos duros nas superfícies críticas. Recentemente foram desenvolvidos revestimentos contendo carbonetos de titânio formados pela fusão de misturas contendo cavacos das ligas ASTM F67 e ASTM F136 sobre peças de aço-carbono ASTM A-36. Após a aplicação do processo de soldagem GTAW obteve-se significativa fração volumétrica de TiC grosseiro com elevada dureza. No presente trabalho foi investigada a refusão dessas soldas pelo processo de soldagem a Laser Nd:YAG pulsado. A microestrutura das amostras foi analisada por difração de raios-X (DRX), microscopia eletrônica de varredura (MEV) e microdureza Vickers. A caracterização microestrutural mostrou que houve refinamento dos carbonetos de titânio (TiC) na matriz ferrítica refundida com o Laser, cujo principal efeito foi um endurecimento do metal de solda. A caracterização mecânica demonstrou um aumento na microdureza da superfície do material. Este comportamento favorece o uso da refusão a Laser para a melhoria da qualidade das superfícies que demandam maior resistência ao desgaste abrasivo. / The abrasive wear is one of the causes of failures in equipment and responsible for damages in industrial processes. A technique capable of minimizing the effects of this phenomenon is the application of hard coatings on critical surfaces. Recently, coatings containing titanium carbides produced by melting mixtures containing ASTM F67 and ASTM F136 chip blends on ASTM A-36 carbon steel parts have been developed. After an application of the GTAW get process, an important volumetric fraction of coarse TiC with high hardness was obtained. In the present work the remelts is investigated for welds by the pulsed Nd: YAG Laser process. A microstructure of the samples was analyzed by X-ray diffraction (XRD), scanning electron microscopy (SEM) and Vickers microhardness. The microstructural characterization showed that there was a refinement of the titanium carbides (TiC) in the ferritic matrix remelt with the Laser, whose main effect was a hardening of the weld metal. The mechanical characterization showed an increase in the microhardness of the material surface. This behavior favors the use of laser cladding to improve the quality of surfaces that require high abrasive wear resistance.
373

Efeito de oxigênio na biocompatibilidade e propriedades da liga Ti-15Mo

Martins Júnior, José Roberto Severino [UNESP] 23 September 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:19Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-09-23Bitstream added on 2014-06-13T19:18:57Z : No. of bitstreams: 1 martinsjunior_jrs_me_bauru.pdf: 3438842 bytes, checksum: c98511273a55e7af07b24dd5b19c844f (MD5) / Desde 1970, o titânio e algumas de suas ligas são vastamente usados na fabrição de próteses e dispositivos especiais nas áreas médica e odontológica devido às suas propriedades como baixos valores de módulo de elasticidade (Módulo de Young), resistência à corrosão e características de biocompatibilidade. A presença de elementos intersticiais (oxigênio, carbono, nitrogênio e hidrogênio) altera de maneira significativa as propriedades mecânicas da liga, principalmente suas propriedades elásticas, causando endurecimento ou fragilização da liga. As medidas de espectroscopia mecânica constituem uma ferramenta poderosa para o estudo da interação destes elementos substitucionais e intersticiais com a matriz metálica. O objetivo do trabalho foi prepararA LIGA Ti-15Mo por fusão a arco, e estudar a influência de tratamentos térmicos e do oxigênio presente em solução sólida, na estrutura, propriedades mecânicas, químicas, anelásticas e biocompatibilidade da liga. Os resultados de difração de raios X analisados pelo método de Rietveld permitiram quantificar as fases presentes na microestrutura, estando de acordo com as micrografias obtidas. Os resultados de dureza e módulo de elasticidade mostraram ser sensíveis à concentração de oxigênio e à microestrutura da liga. Nos ensaios de corrosão houve uma melhora significativa do potencial de corrosão após as dopagens com oxigênio. As medidas de espectroscopia mecânica apresentaram estruturas de relaxação e foram identificados os processos constituintes. Os ensaios de biocompatibilidade mostraram que a liga em questão pode ser considerada biocompatível / Since 1970, titanium and some of its alloys have been widely used in the manufacture of special devices and prostheses in medical and dental areas due to properties which include low elasticity modulus values, corrosion resistance and characteristics of biocumpatibility. The presence of interstial elements (carbon, nitrogen, oxygen and hydrogen) significantly alters the alloy's mechanical properties, mainly its elastic properties, causing either a hardening or softening of the alloy. Mechanical spectroscopy measurements are a powerful tool to study the interaction of these substitutional and interstitial elements with a metallic matrix. The aim of this work was to prepare the Ti-15Mo alloy by arc-melting and study the influence of heat treatments and oxygen present in the solid solution of the structure, as well as the mechanical, chemical and anelastic properties, and biocompatibility of the alloys. The results of x-ray diffraction were analyzed by the Rietveld Method to allow the phases present in the microestructure to be quantified according to the obtained micrographies. The hardness and elasticity modulus results were sensitive to the oxygen concentration and the alloy microstructure. In corrosion tests there was a significant improvement of the corrosion potential after the oxygen dopyng. The mechanical spectroscopy measurements showed relaxation structures, and constituent relaxation processes were identified. The biocompatibility tests showed that the alloy in question can be considered biocompatible
374

Revêtement de Phosphate de calcium sur dioxyde de titane pour des implants métalliques pour des applications médicales / Compound coatings of Ca-phosphates and/ titanate on metallic implants for medical applications

Mohamed, Ibrahim 10 September 2013 (has links)
Pour combiner les bonnes propriétés mécaniques des matériaux métalliques et obtenir des surfaces bioactives, des revêtements de phosphate de calcium (Ca-P) ont été développés. Le but est d’améliorer la biocompatibilité et la bioactivité du système et créer une barrière contre l’éventuelle libération d’ions toxiques du substrat métallique. Notre démarche a été de développer une nouvelle voie de synthèse. Après un polissage mécanique et décapage chimique du substrat de Titane ou Ti–6Al–4V une couche intermédiaire en titanate de sodium a été obtenue par un prétraitement alcalin sur les substrats. Elle a été ensuite soumise à un traitement thermique afin de créer une couche alvéolaire nanométrique. Celle-ci facilite la croissance une couche de phosphate de calcium par voie autocatalytique d'une manière similaire au procédé de formation de l'os naturel. La caractérisation et l’étude des revêtements des Ca-P obtenus par les trois bains (acides, alcalins et oxydant) sur les substrats métalliques ont été réalisés. Les dépôts ont été étudiés d’un point de vue structural et morphologique. La stabilité des couches de Ca-P a été mesurée dans le fluide corporel (SBF) pour des périodes différentes utilisant des analyses biochimiques. En conclusion, cette méthode est une solution peu coûteuse, fiable, et utilisable à l'échelle industrielle. La couche de Ca-P aussi bien que le titanate de sodium obtenus peuvent permettre d’être imprégnés par des agents actifs comme un ou plusieurs agents antibactériens. / To combine the good mechanical properties of metallic substrate with the bioactivity of some ceramics, to obtain bioactive surface, a calcium phosphate (Ca-P) coating has been developed. The goal is to improve the biocompatibility and bioactivity of metallic implant and create a barrier against the possible release of toxic ions from the metallic substrate. Our approach has been to develop a new synthetic route. After mechanical polishing and chemical etching of the titanium or Ti-6Al-4V substrates, an interlayer of sodium titanate was obtained by an alkaline pretreatment of the substrates. Then, it was subjected to a heat treatment to create a nanometeric layer. The latter facilitates the growth of a layer of Ca-P by means of an electroless manner similar to the forming process of the natural bone. Characterization and study of Ca-P coatings obtained by the three baths (acids, alkalis and oxidizing) on metallic substrates have been made. The deposits were studied from a structural and morphological point of view. The stability of Ca-P layers was measured in simulated body fluid (SBF) for different periods using biochemical analyzes. In conclusion, this method is a cheap and reliable solution that can be used on an industrial scale. The Ca-P as well as the sodium titanate layers can afford to be impregnated with active agents such as one or more antibacterial agents.
375

Produção, deformação a frio e recristalização da liga Ti-35Nb-0,15Si / Production, cold deformation and recrystallization of the Ti-35Nb-0,15Si alloy

Cabral, Helton José Rodrigues 30 August 2013 (has links)
This work studied the deformation and recrystallization in Ti-35Nb-0,15Si alloy. Were produced alloys with four different compositions in arc melting furnace under controlled argon atmosphere. The amount of Nb was kept constant at 35 wt% and the amount of Si ranging between 0.15 and 0.55% wt%. The amount of Ti ranging according amount of Si. The alloys were homogenized at 1000 ° C for 8 hours, and then cold-deformed by compression in a matrix. Deformed alloys were recrystallized at the temperatures of 500, 600 and 700 ° C for 1 hour in the differential thermal analysis equipment (DTA). Were used techniques of the optical microscopy, X-ray diffraction and microhardness to evaluate the changes caused by the deformation and the recrystallization. The alloy with the composition Ti-35Nb-0, 15Si showed the highest level of deformation, resulting in increased hardness and formation of a martensitic phase. DTA curves provide information about the ß transus temperature, recovery and recrystallization of the alloys. The recrystallization at 500, 600 and 700 ° C propitiated stress relief, decreasing in the amount of a" and hardness reduction. / Este trabalho estudou a deformação e recristalização em ligas de Ti-Nb-Si. Foram produzidas ligas com quatro composições diferentes em forno de fusão a arco sob atmosfera controlada de argônio. A quantidade de Nb foi mantida constante em 35% em peso e a quantidade de Si variou entre 0,15 e 0,55% em peso. A quantidade de Ti variou de acordo com a quantidade de Si. As ligas produzidas foram homogeneizadas a 1000 °C por 8 horas e posteriormente deformadas a frio em uma matriz via compressão. As ligas deformadas foram recristalizadas nas temperaturas de 500, 600 e 700 °C por 1 hora no equipamento de análise térmica diferencial (DTA). Foram utilizadas as técnicas de microscopia óptica, difração de raios-X e microdureza Vickers para avaliar as mudanças ocasionadas pela deformação e pela recristalização. A liga com composição Ti-35Nb-0,15Si foi a que apresentou maior nível de deformação, gerando aumento na microdureza e formação da fase martensítica a . As curvas de DTA forneceram informações a respeito das temperaturas ß transus, recuperação e recristalização das ligas As recristalizações a 500, 600 e 700 oC propiciaram alívio das tensões, diminuição da quantidade de a e redução da microdureza.
376

Avaliação dos filmes oxidos crescidos anodicamente na liga Ti-6Al-7Nb, pela tecnica de impedancia eletroquimica, para aplicação como biomaterial / Evaluation of anodic oxide films in Ti-6Al-7Nb alloy, through electrochemical impedance technique, to be applied as biomaterial

Kawakami, Kenji 30 August 1996 (has links)
Orientador: Margarita Ballester F. Santos / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-22T11:08:57Z (GMT). No. of bitstreams: 1 Kawakami_Kenji_D.pdf: 19175620 bytes, checksum: b6a661ea70e2abc1018ffcac8a295caa (MD5) Previous issue date: 1996 / Resumo: Não informado / Abstract: In this work is developped a procedure for evaluation of oxides films properties. Through Electrochemical Impedance Spectroscopy, by obtaining from Bode diagrams a capacitance and dissipation coefficient. It is proposed a mathematical model for the metal-oxide-eletrolute system description based on na equivalent circuit. The oxide films properties are evaluated by fitting procedure. The technique . is applied to Ti-6AI-7Nb anodized alloys, used as a substitute for Ti-6AI-4Valloy, in surgical aplications. The results show the possibility of film properties evaluation from direct analysis of Bode diagrams / Doutorado / Materiais e Processos de Fabricação / Doutor em Engenharia Mecânica
377

Obtenção de ligas à base de titânio-nióbio-zircônio processados com hidrogênio e metalurgia do pó para utilização como biomateriais / Obtention of titanium-niobium-zirconium alloys processed with hydrogen and powder metallurgy for use as biomaterials

DUVAIZEM, JOSE H. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:24Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:07Z (GMT). No. of bitstreams: 0 / Biomateriais para uso em implantes devem exibir propriedades como biocompatibilidade, biofuncionalidade e resistência à corrosão. O uso do titânio e suas ligas em aplicações biomédicas vem continuamente aumentando devido à sua maior taxa resistência-peso, superior biocompatibilidade e resistência à corrosão, boas propriedades mecânicas e baixo módulo de elasticidade quando comparado a outros materiais biomateriais metálicos como aço inox e ligas Co-Cr. Um importante aspecto para o sucesso de um implante é a utilização de materiais com módulo de elasticidade baixo, próximo ao do osso, pois estudos indicam que a transferência insuficiente de carga entre implante e osso pode resultar em reabsorção óssea e afrouxamento do implante, que é chamado efeito de blindagem de tensão (stress shielding effect). A liga ternária Ti13Nb13Zr apresenta em sua composição somente elementos considerados biocompatíveis, possui menor módulo de elasticidade que ligas Co-Cr, aço inox e Ti6Al4V, e superior resistência à corrosão. Neste trabalho foi estudado o efeito do teor de nióbio e zircônio nas propriedades mecânicas da liga ternária TiNbZr numa faixa de composições com quantidade de titânio constante em 74 %peso e teor de Nb e Zr variando entre 6 e 20 %peso, produzida por metalurgia do pó a partir de pós hidrogenados e método de mistura elementar, após diferentes condições de processamento e tratamentos térmicos. Os resultados de caracterização microestrutural obtidos por MEV e difração de raios X mostraram que o aumento do teor de Nb não produziu alterações significativas na fração volumétrica das fases e e, o aumento do teor de Zr proporcionou o aumento da fração de fase , favorecendo a formação da estrutura de Widmanstätten. O aumento dos teores de Nb e Zr produziram alterações nas microestruturas dos materiais que levaram ao aumento dos valores de módulo de elasticidade e dureza, e com aumento do teor de Zr houve aumento da susceptibilidade à corrosão. Nas condições de processamento utilizadas, a liga Ti13Nb13Zr apresentou as propriedades mecânicas e microestruturais mais indicadas para utilização como biomateriais. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
378

Investigação da resistência a corrosão da liga Ti-13Nb-13Zr por meio de técnicas eletroquímicas e de análise de superfície

ASSIS, SERGIO L. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:29Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:10Z (GMT). No. of bitstreams: 1 11326.pdf: 1707325 bytes, checksum: f4b793f522e5d69e25de853d166b1c79 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
379

Estudo do comportamento mecânico em temperaturas elevadas da liga Ti-6Al-4V após tratamento superficial de nitretação por plasma / High temperature mechanical behavior of the TI-6AL-4V alloy after plasma nitriding

ALMEIDA, GISELE F.C. 22 November 2017 (has links)
Submitted by Pedro Silva Filho (pfsilva@ipen.br) on 2017-11-22T18:22:46Z No. of bitstreams: 0 / Made available in DSpace on 2017-11-22T18:22:46Z (GMT). No. of bitstreams: 0 / A liga Ti-6Al-4V é uma das ligas de titânio mais suas aplicações estruturais em temperaturas elevadas são limitadas devido a sua afinidade pelo oxigênio. Um tratamento superficial que melhore a resistência à oxidação desta liga permitindo a substituição de peças que atualmente são produzidas com superligas de Ni por este material, poderia reduzir significativamente o peso destes componentes. O objetivo deste trabalho é melhorar a resistência à fluência desta liga utilizando nitretação por plasma. Para homogeneizar a microestrutura do material, foi realizado um tratamento térmico a 1050ºC por 30 minutos para obtenção da microestrutura de Widmanstätten que foi a que apresentou melhor resistência à fluência no material sem tratamento. A nitretação foi realizada variando parâmetros de processo como tempo, temperatura e mistura de gases na atmosfera. A partir dos resultados obtidos, a mistura de gás de Ar:N2:H2 (0,49:0,49:0,03) a 700°C por 4 horas foi a condição escolhida. A caracterização da camada nitretada foi realizada por técnicas de microscopia ótica e eletrônica de varredura, além de difração de raios X. As fases da amostra nitretada detectadas por DRX foram o ε-Ti2N e δ-TiN, além das fases α e β da matriz. A espessura da camada nitretada foi de cerca de 1 μm. Os ensaios de tração a quente foram realizados em temperaturas entre 500°C e 700°C no material com e sem nitretação e mostraram um aumento na resistência da liga nitretada de até 29% nos limites de escoamento e resistência. Os ensaios de fluência foram realizados variando a temperatura também entre 500 e 700ºC e tensão aplicada entre 125 e 319 MPa. O resultado foi um aumento na resistência à fluência do material nitretado. Isto foi evidenciado pela diminuição da taxa de fluência secundária e também pelo aumento do tempo de ruptura do material. / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
380

Caracterização de revestimentos de TiO2 depositados por aspersão termica a plasma sobre a liga Ti-13Nb-13Zr / Covering characterization of TiO2 deposited by plasma thermal aspersion on the alloy Ti-13Nb-13Zr

Santos, Jose Carlos Sousa dos 12 August 2018 (has links)
Orientador: Cecilia Amelia de Carvalho Zavaglia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-12T14:04:29Z (GMT). No. of bitstreams: 1 Santos_JoseCarlosSousados_M.pdf: 6317167 bytes, checksum: 3007b440a82fcaab621d5cef423c3334 (MD5) Previous issue date: 2008 / Resumo: A liga Ti-13Nb-13Zr tem sido proposta em estudos de pesquisa como uma nova alternativa dentre as ligas biomédicas por apresentar em sua formulação alguns dos elementos metálicos de maior compatibilidade como: titânio, nióbio e zircônio; considerados como metais válvulas, onde apresentam excelente resistência à corrosão, excelente propriedades mecânicas e baixa densidade. O substrato da liga Ti-13Nb-13Zr foi revestido com titânia (TiO2) por aspersão térmica a plasma visando viabilizar a sua utilização como implantes biomédicos. Foram utilizadas técnicas de caracterização desses substratos revestidos para avaliar os efeitos da titânia sobre as propriedades mecânicas e físico-químicas da liga Ti-13Nb-13Zr. Foram obtidos revestimentos de boa qualidade com baixa porosidade, baixo nível de partículas não fundidas e com boa adesão. O ensaio de riscamento com e sem tratamento térmico não apresentou alterações significativas nos valores da carga crítica. Os resultados experimentais obtidos do substrato da liga Ti-13Nb-13Zr revestido com titânia após o ensaio de riscamento apresentou uma boa adesão do depósito ao substrato o que viabilizará em futuro o seu uso em implantes ortopédicos. / Abstract: The Ti-13Nb-13Zr alloy has been proposed by researchers as new alternative amongst the biomedical alloys for presenting on its composition some of the metallic elements of better compatibility; as titanium, niobium and zirconium; considered as metals valves, by presenting excellent corrosion resistance, excellent mechanical properties and low density. The Ti-13Nb-13Zr alloy substratum was coated with titanium dioxide (TiO2) by plasma thermal aspersion aiming its biomedical application. Titanium influence on the mechanical and physico-chemical properties was determined and coatings were found to be of good quality exhibiting low content of an melted particles and good adhesion. The scratch test with and without thermal treatment did not have significant alterations on the values of the critical load. The results obtained on these experiments showed that TiO2 coating on Ti-13Nb-13Zr alloys has good potencial for orthopedics implantations since it exhibits good adhesion and good mechanical properties. / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica

Page generated in 0.0399 seconds