• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 522
  • 314
  • 129
  • 76
  • 51
  • 7
  • Tagged with
  • 1083
  • 470
  • 254
  • 195
  • 171
  • 149
  • 131
  • 126
  • 120
  • 116
  • 97
  • 90
  • 89
  • 87
  • 86
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
571

Conception d’un procédé de microfabrication pour l’assemblage 3D puce-à-puce de circuits intégrés hétérogènes à des fins de prototypage

Maurais, Luc January 2018 (has links)
L’utilisation de photodiodes avalanche monophotoniques (PAMP) pour une utilisation au sein d’imageur préclinique par tomographie d’émission par positrons est d’intérêt. En effet, l’utilisation de ces photodétecteurs intégrés au CMOS est poussée par leurs excellentes performances de résolution en temps ainsi que leur haute sensibilité. Cependant, l’utilisation de ces détecteurs nécessite également un circuit intégré de contrôle visant à protéger les photodiodes de courants trop élevés lors de déclenchement d’avalanches et de contrôler leurs temps mort. Ces circuits de plus en plus sophistiqués nécessitent un espace significatif diminuant ainsi la surface photosensible à la surface de la puce et diminuant leurs sensibilités. L’assemblage 3D puce-à-puce est donc nécessaire dans le but d’augmenter la surface photosensible et de ne pas limiter les fonctionnalités de contrôles électroniques individuelles à chaque PAMP. Ce document présente le développement d’un procédé d’assemblage 3D puce-à-puce visant l’intégration de matrices de PAMP. Les étapes de microfabrication nécessaires visent l’intégration d’interconnexions verticales au travers du substrat (TSV) permettant de transmettre les signaux d’une couche à l’autre et le collage 3D de ceux-ci. De plus, des mesures de caractéristiques de bruits ont été effectuées sur des puces ayant subi certaines étapes de microfabrication du procédé d’assemblage 3D. Ces mesures ont été effectuées dans le but de déterminer l’impact potentiel du procédé d’assemblage sur les performances des PAMP intégrés en 3D.
572

Système intelligent de détection et diagnostic de fautes en tomographie d'émission par positrons

Charest, Jonathan January 2017 (has links)
La tomographie d'émission par positrons (TEP) est un outil de choix en imagerie moléculaire grâce à sa capacité à quantifier certains métabolismes et à porter des diagnostics précis sur l'évolution de pathologies. Cependant, la qualité du diagnostic est dépendante de la qualité de l'image obtenue. La complexité des appareils TEP fait en sorte que ceux-ci nécessitent des calibrations fréquentes demandant un professionnel qualifié dans le domaine que très peu de laboratoires pourvus d'un scanner possèdent. Conséquemment, ce projet vise à concevoir un système intelligent pouvant détecter des fautes et porter un diagnostic sur un scanner TEP de façon automatique dans le but de maximiser la qualité des images produites. Le système intelligent développé permettra alors de pallier à la surcharge ou à l'absence d'un professionnel en laboratoire puisqu'il automatisera le contrôle de qualité de l'appareil. Le projet englobe donc: l'identification de données permettant de détecter et diagnostiquer les fautes, l'implantation de système intelligent par module et de façon hiérarchique, la validation de l'exactitude des diagnostics et finalement l'évaluation de l'impact du système sur la qualité des images produites par le scanner. Pour arriver à son but, le système intelligent met en oeuvre différentes méthodes d'intelligence artificielle comprenant des réseaux de neurones artificiels, un système expert à base de règles et diverses méthodes de traitement de signal. Ce projet se penche plus spécifiquement sur le scanner LabPET, un scanner TEP pour petits animaux développé à Sherbrooke. LabPET est un bon candidat car il comporte un nombre élevé de canaux non interdépendants accentuant ainsi les bénéfices de la parallélisation apportés par le système proposé. Ainsi, les travaux ont permis de réaliser un système ayant une efficacité de détection et une exactitude de diagnostic dépassant les attentes et, une étude de l'impact du système sur la qualité des images a démontré une amélioration significative des paramètres de qualité d'image. Il en découle que le système est bien en mesure d'aider les professionnels dans l'entretien du scanner LabPET. Les résultats devraient permettre de promouvoir le développement de systèmes intelligents de détection et de diagnostic de fautes d'appareils TEP. Des systèmes similaires seront certainement nécessaires au bon fonctionnement des prochaines générations d'appareils TEP, et les résultats de ce projet pourront alors servir de référence.
573

Iterative tomographic X-Ray phase reconstruction / Reconstruction tomographique itérative de phase

Weber, Loriane 30 September 2016 (has links)
L’imagerie par contraste de phase suscite un intérêt croissant dans le domaine biomédical, puisqu’il offre un contraste amélioré par rapport à l’imagerie d’atténuation conventionnelle. En effet, le décalage en phase induit par les tissus mous, dans la gamme d’énergie utilisée en imagerie, est environ mille fois plus important que leur atténuation. Le contraste de phase peut être obtenu, entre autres, en laissant un faisceau de rayons X cohérent se propager librement après avoir traversé un échantillon. Dans ce cas, les signaux obtenus peuvent être modélisés par la diffraction de Fresnel. Le défi de l’imagerie de phase quantitative est de retrouver l’atténuation et l’information de phase de l’objet observé, à partir des motifs diffractés enregistrés à une ou plusieurs distances. Ces deux quantités d’atténuation et de phase, sont entremêlées de manière non-linéaire dans le signal acquis. Dans ces travaux, nous considérons les développements et les applications de la micro- et nanotomographie de phase. D’abord, nous nous sommes intéressés à la reconstruction quantitative de biomatériaux à partir d’une acquisition multi-distance. L’estimation de la phase a été effectuée via une approche mixte, basée sur la linéarisation du modèle de contraste. Elle a été suivie d’une étape de reconstruction tomographique. Nous avons automatisé le processus de reconstruction de phase, permettant ainsi l’analyse d’un grand nombre d’échantillons. Cette méthode a été utilisée pour étudier l’influence de différentes cellules osseuses sur la croissance de l’os. Ensuite, des échantillons d’os humains ont été observés en nanotomographie de phase. Nous avons montré le potentiel d’une telle technique sur l’observation et l’analyse du réseau lacuno-canaliculaire de l’os. Nous avons appliqué des outils existants pour caractériser de manière plus approfondie la minéralisation et les l’orientation des fibres de collagènes de certains échantillons. L’estimation de phase, est, néanmoins, un problème inverse mal posé. Il n’existe pas de méthode de reconstruction générale. Les méthodes existantes sont soit sensibles au bruit basse fréquence, soit exigent des conditions strictes sur l’objet observé. Ainsi, nous considérons le problème inverse joint, qui combine l’estimation de phase et la reconstruction tomographique en une seule étape. Nous avons proposé des algorithmes itératifs innovants qui couplent ces deux étapes dans une seule boucle régularisée. Nous avons considéré un modèle de contraste linéarisé, couplé à un algorithme algébrique de reconstruction tomographique. Ces algorithmes sont testés sur des données simulées. / Phase contrast imaging has been of growing interest in the biomedical field, since it provides an enhanced contrast compared to attenuation-based imaging. Actually, the phase shift of the incoming X-ray beam induced by an object can be up to three orders of magnitude higher than its attenuation, particularly for soft tissues in the imaging energy range. Phase contrast can be, among others existing techniques, achieved by letting a coherent X-ray beam freely propagate after the sample. In this case, the obtained and recorded signals can be modeled as Fresnel diffraction patterns. The challenge of quantitative phase imaging is to retrieve, from these diffraction patterns, both the attenuation and the phase information of the imaged object, quantities that are non-linearly entangled in the recorded signal. In this work we consider developments and applications of X-ray phase micro and nano-CT. First, we investigated the reconstruction of seeded bone scaffolds using sed multiple distance phase acquisitions. Phase retrieval is here performed using the mixed approach, based on a linearization of the contrast model, and followed by filtered-back projection. We implemented an automatic version of the phase reconstruction process, to allow for the reconstruction of large sets of samples. The method was applied to bone scaffold data in order to study the influence of different bone cells cultures on bone formation. Then, human bone samples were imaged using phase nano-CT, and the potential of phase nano-imaging to analyze the morphology of the lacuno-canalicular network is shown. We applied existing tools to further characterize the mineralization and the collagen orientation of these samples. Phase retrieval, however, is an ill-posed inverse problem. A general reconstruction method does not exist. Existing methods are either sensitive to low frequency noise, or put stringent requirements on the imaged object. Therefore, we considered the joint inverse problem of combining both phase retrieval and tomographic reconstruction. We proposed an innovative algorithm for this problem, which combines phase retrieval and tomographic reconstruction into a single iterative regularized loop, where a linear phase contrast model is coupled with an algebraic tomographic reconstruction algorithm. This algorithm is applied to numerical simulated data.
574

Study of generalized Radon transforms and applications in Compton scattering tomography / Étude de transformées de Radon généralisées et applications en tomographie Compton

Rigaud, Gaël 20 November 2013 (has links)
Depuis l'avènement des premiers appareils imageurs par rayonnement ionisant initié par les prix Nobel Godfrey Newbold Hounsfield et Allan MacLeod Cormack en 1979, le besoin en de nouvelles techniques d'imagerie non invasives n'a cessé de croître. Ces techniques s'appuient sur les propriétés de pénétration dans la matière des rayonnements X et gamma pour détecter une structure cachée sans avoir à détruire le milieu exposé. Elles sont employées dans de nombreux domaines allant de l'imagerie médicale au contrôle non destructif en passant par le contrôle environnemental. Cependant les techniques utilisées jusqu'à maintenant subissent de fortes dégradations dans la qualité des mesures et des images reconstruites. Généralement approchées par un bruit, ces dégradations exigent d'être compensées ou corrigées par des dispositifs de collimation et de filtrage souvent coûteux. Ces dégradations sont principalement dues aux phénomènes de diffusion qui peuvent constituer jusqu'à 80 % du rayonnement émis en imagerie biomédicale. Dès les années 80 un nouveau concept a vu le jour pourcontourner cette difficulté : la tomographie Compton. Cette nouvelle approche propose de mesurer le rayonnement dit diffusé en se plaçant dans des gammes d'énergie (140−511 keV) où l'effet Compton est le phénomène de diffusion prépondérant. L'exploitation de tels dispositifs d'imagerie nécessite une compréhension profonde des interactions rayonnement/matière afin de proposer un modèle, cohérent avec les données mesurées, indispensable à la reconstruction d'images. Dans les systèmes d'imagerie conventionnels (qui mesurent le rayonnement primaire), la transformée de Radon définie sur les lignes droites est apparue comme le modèle naturel. Mais en tomographie Compton, l'information mesurée est liée à l'énergie de diffusion et ainsi à l'angle de diffusion.Ainsi la géométrie circulaire induite par le phénomène de diffusion rend la transformée de Radon classique inadaptée. Dans ce contexte, il devient nécessaire de proposer des transformées de type Radon sur des variétés géométriques plus larges.L'étude de la transformée de Radon sur de nouvelles diversités de courbes devient alors nécessaire pour répondre aux besoins d'outils analytiques de nouvelles techniques d'imagerie. Cormack, lui-même, fut le premier à étendre les propriétés de la transformée de Radon classique à une famille de courbes du plan. Par la suite plusieurs travaux ont été menés dans le but d'étudier la transformée de Radon définie sur différentes variétés de cercles, des sphères, des lignes brisées pour ne citer qu'eux. En 1994 S.J. Norton proposa la première modalité de tomography Compton modélisable par une transformée de Radon sur lesarcs de cercle, la CART1. En 2010 Nguyen et Truong établirent l'inversion de la transformée de Radon sur les arcs de cercle, CART2, permettant de modéliser la formation d'image dans une nouvelle modalité de tomographie Compton. La géométrie des supports d'intégration impliqués dans de nouvelles modalitésde tomographie Compton les conduirent à démontrer l'invertibilité de la transformée de Radon définie sur une famille de courbes de type Cormack, appelée C_alpha. Ils illustrèrent la procédure d'inversion dans le cadre d'une nouvelle transformée, la CART3 modélisant une nouvelle modalité de tomographie Compton.En nous basant sur les travaux de Cormack et de Truong et Nguyen, nous proposons d'établir plusieurs propriétés de la transformée de Radon définie sur la famille C_alpha et plus particulièrement sur C1. Nous avons ainsi démontré deux formules d'inversion qui reconstruisent l'image d'origine via sa décompositionharmonique circulaire et celle de sa transformée et qui s'apparentent à celles établies par Truong and Nguyen. Nous avons enfin établi la bien connue rétroprojection filtrée ainsi que la décomposition en valeurs singulières dans le cas alpha = 1. L'ensemble des résultats établis dans le cadre de cette étude apporte des réponses concrètes a / Since the advent of the first ionizing radiation imaging devices initiated by Godfrey Newbold Hounsfield and Allan MacLeod Cormack, Nobel Prizes in 1979, the requirement for new non-invasive imaging techniques has grown. These techniques rely upon the properties of penetration in the matter of X and gamma radiation for detecting a hidden structure without destroying the illuminated environment. They are used in many fields ranging from medical imaging to non-destructive testing through. However, the techniques used so far suffer severe degradation in the quality of measurement and reconstructed images. Usually approximated by a noise, these degradations require to be compensated or corrected by collimating devices and often expensive filtering. These degradation is mainly due to scattering phenomena which may constitute up to 80% of the emitted radiation in biological tissue. In the 80's a new concept has emerged to circumvent this difficulty : the Compton scattering tomography (CST).This new approach proposes to measure the scattered radiation considering energy ranges ( 140-511 keV) where the Compton effect is the phenomenon of leading broadcast. The use of such imaging devices requires a deep understanding of the interactions between radiation and matter to propose a modeling, consistent with the measured data, which is essential to image reconstruction. In conventional imaging systems (which measure the primary radiation) the Radon transformdefined on the straight lines emerged as the natural modeling. But in Compton scattering tomography, the measured information is related to the scattering energy and thus the scattering angle. Thus the circular geometry induced by scattering phenomenon makes the classical Radon transform inadequate.In this context, it becomes necessary to provide such Radon transforms on broader geometric manifolds.The study of the Radon transform on new manifolds of curves becomes necessary to provide theoretical needs for new imaging techniques. Cormack, himself, was the first to extend the properties of the conventional Radon transform of a family of curves of the plane. Thereafter several studies have been done in order to study the Radon transform defined on different varieties of circles, spheres, broken lines ... . In 1994 S.J. Norton proposed the first modality in Compton scattering tomography modeled by a Radon transform on circular arcs, the CART1 here. In 2010, Nguyen and Truong established the inversion formula of a Radon transform on circular arcs, CART2, to model the image formation in a new modality in Compton scattering tomography. The geometry involved in the integration support of new modalities in Compton scattering tomography lead them to demonstrate the invertibility of the Radon transform defined on a family of Cormack-type curves, called C_alpha. They illustrated the inversion procedure in the case of a new transform, the CART3, modeling a new modeling of Compton scattering tomography. Based on the work of Cormack and Truong and Nguyen, we propose to establish several properties of the Radon transform on the family C_alpha especially on C1. We have thus demonstrated two inversion formulae that reconstruct the original image via its circular harmonic decomposition and itscorresponding transform. These formulae are similar to those established by Truong and Nguyen. We finally established the well-known filtered back projection and singular value decomposition in the case alpha = 1. All results established in this study provide practical problems of image reconstruction associated with these new transforms. In particular we were able to establish new inversion methods for transforms CART1,2,3 as well as numerical approaches necessary for the implementation of these transforms. All these results enable to solve problems of image formation and reconstruction related to three Compton scattering tomography modalities.In addition we propose to improve models and algorithms es
575

Amélioration de la résolution spatiale en microscopie multiphotonique par saturation de la fluorescence

Nguyen, Anh Dung 11 December 2015 (has links)
-------------------------------Abstract--------------------------------Since the prediction by Maria Göppert-Mayer in the thirties of the possibility for a fluorescent molecule to be simultaneously excited by multiple photons and, more recently, the development of pulsed lasers, multiphoton microscopy has gradually evolved to finally become one of the most used fluorescent imaging techniques for the studies of thick scattering tissues or for in vivo observations of animals. Either for neurological, physiological or morphological studies, the non invasiveness and the limitation of the excited volume to the focal volume have made this fluorescence microscopy technique an essential tool for biologists.However, in a world where the biological studies always require better microscopes and where there is always a need for the spatial resolution to be improved, it is essential to offer techniques allowing to obtain a better resolution in the three dimensions and to access resolution beyond the diffraction limit defined by Ernst Abbe more than a century ago. In this thesis, the saturated excitation of fluorescence technique is adapted to multiphoton microscopy. This method achieves super-resolved images by temporally modulating the excitation laser-intensity and by demodulating the higher harmonics from the saturated fluorescence signal. As a proof of principle, the improvement of the lateral and axial resolution has been measured on a sample of fluorescent microspheres. While the third harmonic already provides an enhanced resolution, we show in this work that a further improvement can be obtained with an appropriate linear combination of the demodulated harmonics.In the end, a near twofold improvement of the resolution has been obtained in the lateral but also in the axial directions. This improvement is in agreement with the estimated resolution improvement predicted in the theoretical and the mathematical analysis of the technique carried out in this work.We also present in vitro imaging of fluorescent microspheres incorporated in HeLa cells. Enhancements of lateral and axial resolution has been observed, showing that this super-resolution technique performs well in biological samples.Finally, the strengths and weaknesses of the technique have also been analysed and detailed to see in which niche in the world of biological imaging this method can find its place. To this end, its characteristics are compared to other super-resolution and super-localisation techniques that have been previously studied in this thesis.It points out that the imaging depth, the non invasiveness and the relatively low illumination power on the samples but also the limitation of the excited volume in multiphoton microscope coupled with the simple and cost-effective implementation as well as the relatively low illumination power on the sample used in the saturated excitation technique make this method an excellent candidate for deep in vivo studies trough scattering tissue like the skin. / -----------------------Résumé-----------------------Depuis la prédiction de Maria Göppert-Mayer dans les années 30 de la possibilité pour une molécule fluorescente d'être excitée simultanément par plusieurs photons et, plus récemment, depuis le développement des lasers pulsés, la microscopie multiphotonique s'est peu à peu développée pour finalement s'imposer aujourd'hui comme un des outils d'observation par fluorescence les plus performants pour les études de tissus épais diffusants, ou encore pour l'observation in vivo d'animaux. Que ce soit pour des études neurologiques, physiologiques ou morphologiques, l'aspect non invasif et la limitation du volume excité au volume focal ont rendu cet outil de microscopie indispensable aux biologistes.Cependant, dans un monde où les études biologiques nécessitent toujours de meilleurs microscopes et où la résolution spatiale en particulier doit toujours être améliorée, il convient de proposer des techniques permettant d'obtenir une meilleure résolution dans les trois dimensions et d'aller au-delà de la limite de diffraction définie par Ernst Abbe il y a plus d'un siècle.Dans cette thèse, la technique de saturation de l'excitation de la fluorescence est adaptée à la microscopie multiphotonique. Cette méthode permet d'obtenir des images de superrésolution en modulant temporellement l'intensité laser d'excitation et en démodulant les harmoniques supérieures présentes dans le signal saturé de fluorescence. La démonstration de principe sur des microsphères fluorescentes a été réalisée montrant une amélioration de la résolution latérale et axiale. Alors que l'utilisation de la troisième harmonique produit déjà une meilleure résolution, ce travail de thèse montre qu'une amélioration supplémentaire peut être obtenue en utilisant une combinaison linéaire particulière des harmoniques démodulées.Au final, un quasi doublement de la résolution a pu être observé tant dans les directions latérales que dans la direction axiale. Cette amélioration correspond à l'amélioration prédite dans l'analyse théorique et mathématique réalisée également dans ce travail.De plus, le passage aux études in vitro a été réalisé avec succès en observant des microsphères fluorescentes incorporées dans des cellules HeLa. Des améliorations de la résolution latérale et axiale ont également été observées montrant que cette technique de superrésolution peut être appliquée à l'étude d'échantillons biologiques. Les forces et les faiblesses de cette méthode sont également analysées et détaillées afin de voir dans quel créneau d'études biologiques la technique de saturation de l'excitation de fluorescence pourrait se faire une place. A cette fin, ses caractéristiques sont comparées aux autres méthodes de superrésolution et de superlocalisation détaillées dans la première partie de ce travail.Il en resort que l'importante profondeur d'imagerie, l'aspect non invasif et la limitation du volume excité de la microscopie multiphotonique couplés à la simplicité d'implémentation et les relativement faibles puissances utilisées pour saturer l'excitation font de cette technique un excellent candidat pour des études in vivo dans des zones en profondeur dans des milieux diffusants comme la peau. / Doctorat en Sciences de l'ingénieur et technologie / info:eu-repo/semantics/nonPublished
576

Chronic allograft rejection in lung transplant recipients: assessment with paired inspiratory and expiratory CT

Bankier, Alexandre 20 June 2011 (has links)
This work discusses the role of CT in the etection and quantification of chronic allograft rejection in patients after lung transplantation and provides solutions to the technical challenges involved with this approach. / Doctorat en Sciences médicales / info:eu-repo/semantics/nonPublished
577

Advanced 3D and in-situ TEM approaches applied to carbon-based and zeolitic nanomaterials / Microscopie électronique 3D et environnementale de nanomatériaux carbones et zéolitiques

Melinte, Georgian 18 September 2015 (has links)
Dans le cadre de cette thèse, des techniques avancées de Microscopie électronique à transmission (MET)ont été utilisées dans le but de caractériser et de fabriquer de nouveaux nanomatériaux pour des applications dans les domaines de la nanoélectronique et de la catalyse. Trois types de matériaux fonctionnalisés sont étudiés: le graphène multifeuillets (FLG– Few-Layer Graphene) avec des nanomotifs,des nanotubes de carbone (CNTs - Carbon Nanotubes en anglais) et des zéolithes mésoporeux. La formation de nanomotifs de tranchées et de tunnels sur des flocons de FLG à l’aide de nanoparticules(NPs) de fer est étudiée dans une approche qui combine la tomographie électronique et la MET environnementale. Le rôle des facettes de la nanoparticule et des paramètres topographiques de FLG a été déterminé du point de vue quantitatif, ce qui a mené à la mise en évidence du mécanisme de formation des nanomotifs de tranchées et de tunnels. Le transfert de nanoparticules à base de métal entre deux nanostructures de carbone a été également étudié, en temps réel, en employant un porte-échantillon MET couplé avec un dispositif STM (Scanning Tunneling Microscope en anglais). Le protocole de contrôle du transfert des nanoparticules, les transformations chimiques et structurales subies par celles-ci, le mécanisme de croissance de nouvelles nanoparticules et d’autres phénomènes liés à ces effets ont été étudiés avec attention. La dernière partie de la thèse est centrée sur l’étude de la tomographie électronique à faible dose de la porosité induite dans deux classes de zéolithes, ZSM-5 et zéolithe Y, en utilisant un traitement chimique novateur à base de fluor. / In this thesis, advanced Transmission Electron Microscopy (TEM) techniques are used to characterize and fabricate new nanomaterials with applications in nanoelectronics and catalysis. Three types of functionalized materials are investigated: nanopatterned few-layer graphene (FLG), carbon nanotubes(CNTs) and mesoporous zeolites. The nanopatterning process of FLG flakes by iron nanoparticles (NPs) is studied using an approach combining electron tomography (ET) and environmental TEM. The role of the nanoparticle faceting and of the FLG topographic parameters has been quantitatively determined leading to the first determination of the operating mechanism of the patterning process. The mass transfer of metallic-based NPs between two carbon nanostructures was studied as well in real-time by using a TEMSTMholder. The protocol of controlling the mass transfer, the chemical and structural transformations of the NPs, the growth mechanism of the new NPs and other related phenomena were carefully investigated.The last part deals with the low-dose ET investigation of the porosity induced in two classes of zeolites,ZSM-5 and zeolite Y, by an innovative fluoride-based chemical treatment.
578

Analyse du comportement mécanique des mousses polymères : apport de la tomographie X et de la simulation numérique / Polymeric foams mechanical behavior analysis : x-ray tomography and numerical simulation contribution

Dabo, Mouhamadou 16 December 2015 (has links)
Les matériaux polymères à structures cellulaires allient des propriétés mécaniques, thermiques, chimiques et optiques intéressantes aux regards des contraintes d’allègement des systèmes et des structures. Toutefois, pour diversifier leurs applications et les rendre toujours plus performants dans les domaines de la santé, du transport ou encore du bâtiment, une étude fine des relations qui lient les procédés de fabrication à la microstructure générée et aux propriétés qui en découlent, doit être menée. Ces propriétés mécaniques dépendent étroitement des propriétés de la matière dont les mousses sont faites mais aussi de la morphologie de leurs microstructures (orientation, distribution et taille des pores, épaisseur des parois). Il est donc crucial de pouvoir quantifier et mesurer ces paramètres pour tendre vers une compréhension fine des propriétés mécaniques et définir des modèles capables de relier le comportement macroscopique du matériau cellulaire vis-à-vis de son « équivalent » massif et de la microstructure. En collaboration étroite avec la direction recherche et développement de l’entreprise INTEREP, leader européen du caoutchouc cellulaire étanche, une caractérisation expérimentale du comportement mécanique de mousses de différentes natures polymériques et de différentes topologies à d’abord été effectuée. Ensuite un ensemble de modélisations géométriques a été développé à partir d’observations microstructurales de vraies mousses en micro-tomographie RX et à partir de microstructures générées virtuellement par le biais d’une description physique du processus de fabrication de mousses polymères. Finalement, une simulation numérique éléments finis en 2D et en 3D de ces microstructures couplées à la caractérisation expérimentale du matériau massif des parois a permis de reproduire et d’étudier finement les mécanismes de déformations observés expérimentalement sur des mousses polymères et d’affiner les lois de comportement empiriques avec la prise en compte d’un paramètre supplémentaire caractéristique de la statistique de distribution des cellules dans l’espace, c'est-à-dire de leurs localisations et de leur distribution de taille et de forme. / Polymer foams materials combine mechanical, thermal, chemical and optical interesting properties going with light weighting structures problems. However, to diversify their applications and make them even more efficient in health field, transportation or building, a fine study of the relationships between manufacturing processes to generated microstructures and resulting properties must be conducted. These mechanical properties are highly depending on the properties of material with which foams are made but also on the morphology of their microstructures (orientation, distribution and pore size, wall thickness). Thus it is crucial to quantify and measure these parameters to strive for a detailed understanding of the mechanical properties and define models capable of linking global behavior of cellular materials to bulk materials and microstructures. Working closely with research and development division of INTEREP, European leader in waterproof cellular rubber, an experimental characterization of the mechanical behavior of polymer foams of different natures and different topologies has been performed first. Then geometrical modeling was developed from micro structural observations of real foams in x-ray micro-tomography and from virtually generated microstructures through a physical description of polymer foams manufacturing process. Finally finite element simulation in 2D and 3D of these microstructures were coupled with the experimental characterization of bulk material allowing thus to reproduce and finely study deformation mechanisms experimentally observed on polymer foams and refine empirical behavior laws by taking into account additional characteristic parameter of cells statistical distribution in space like their location and their size distribution and shape.
579

Asservissement visuel direct fondé sur les ondelettes pour le positionnement automatique d'une sonde de tomographie par cohérence optique / Visual servoing based on the wavelets for automatic positioning of an optical coherence tomography probe

Ourak, Mouloud 08 December 2016 (has links)
Les avancées technologiques ont ouvert la voie à des approches de biopsie optique innovantes. Elles permettent à l'inverse des méthodes physiques de profiter des avantages d'une procédure mini-invasive, temps réels et répétitive. Le système de tomographie par cohérence optique (OCT) (la technique de biopsie optique utilisée dans cette thèse) propose des approches qui naviguent dans le corps humain grâce à des sondes endoscopiques robotisées. Toutefois, leur contrôle une fois à l’intérieur du corps devient difficile, surtout si l’objectif est de suivre l’évolution d'une zone cible, en faisant un travail de repositionnement dans le temps. L'asservissement visuel est un outil de choix pour le contrôle et le positionnement directement par l'image. Néanmoins, la richesse des informations présentes dans les images autorisent l'utilisation de plusieurs types d'information visuelle. Dans ce contexte, nous proposons l'utilisation de primitives visuelles innovantes fondées sur les ondelettes. Ainsi, deux approches d'asservissements visuels fondées sur les ondelettes ont été développées. La première approche est un asservissement visuel 2D pose fondé sur les ondelettes spectrales continues qui assure une convergence sur un espace plus important avec une bonne robustesse au bruit et une commande découplée. La deuxième est un asservissement visuel 2D direct fondé sur les ondelettes multirésolution, principalement pour faire du positionnement aux petits déplacements. Par ailleurs, la deuxième méthode couvre les 6 DDL quand la première se limite aux 3 DDL dans les images CCD. De plus, ces deux approches ont prouvé leurs aptitudes à faire du positionnement des coupes OCT. Mais encore, nous avons proposé une méthode de positionnement partitionnée que nous pouvons qualifier d'hybride, car elle exploite deux modalités d'images (OCT - CCD) pour assurer un positionnement sur SE(3) d'un échantillon. De même, nous avons proposé une méthode d'étalonnage des images de coupe et de volume OCT, liée aux distorsions générées par le chemin optique parcouru par le faisceau laser OCT. Finalement, ces travaux ouvrent la voie vers des applications dans le positionnement des volumes OCT, la compensation de mouvement physiologique et le suivi d'outils par des images OCT. / The technological advances have facilitated the optical biopsy approaches, unlike physical methods to take advantage of a minimally invasive, real time and repetitive procedure. The optical coherence tomography system is one of the optical biopsy techniques used in this thesis to prospect in the human body with robotized OCT endoscopic probes. Nevertheless, their control once inside the body becomes difficult, especially if the goal is following changes in the target area. The visual servoing is an ideal tool for the control and positioning of the robot. However, the amount of information present in the images allows the use of several types of visual features. In this thesis, we propose to use an innovative visual servoing feature based on wavelets. This representation developed as the evolution of the Fourier transform for non-stationary signals provides a time-frequency representation of the signal with a better extraction of the relevant information. Indeed, two visual servoing approaches based on wavelets were developed. The first approach is a 2D pose visual servoing based on spectral continuous wavelets, which ensures convergence over a larger area and decoupled control. The second is a direct 2D visual servoing based on multiresolution wavelets, mainly for small displacements positioning. However, the latter covers the 6 DOF when the previous one is limited to 3 DDL with a CCD camera. Both approaches have proven their ability to make the positioning of B-Scan OCT images. After that, we have proposed a method of partitioned positioning, that we can qualify by hybrid because it uses two image modalities to ensure SE(3) positioning of a sample. On the other side, we proposed a calibration method of B-Scan and 3D-Scan OCT images, due to the distortions generated by the optical path of the laser beam in OCT. Finally, these thesis is a beginning work for applications in positioning of 3D-Scan OCT, physiological motion compensation and monitoring tools by OCT images.
580

Tomographie ultrasonore dédiée à l'imagerie anatomique du sein : Validation expérimentale du projet ANAIS

Rouyer, Julien 15 February 2012 (has links)
La tomographie ultrasonore assistée par ordinateur possède un fort potentiel en tant que moyen d'inspection des tissus mammaires pour le dépistage du cancer du sein; cette technique permet de réduire la dépendance à l'opérateur constatée avec l'échographie conventionnelle. Une antenne de transducteurs (3 MHz) à géométrie semi-circulaire conformée à l'anatomie du sein a été développée pour réaliser une imagerie de réflectivité des structures d'intérêt en employant une procédure de reconstruction tomographique. L'antenne comporte 1024 éléments répartis sur un arc de 190 degrés ayant un rayon de courbure de 100 mm. Les acquisitions sont gérées par une électronique à 32 voies parallèles indépendantes en émission/réception et par un multiplexer pour l'adressage des voies vers les éléments de l'antenne. Les circuits d'émission et de réception ont une fréquence d'échantillonnage allant jusqu'à 80 MHz avec une précision de 12 bits. Des formes d'ondes arbitraires (pseudo-chirp, codes de Golay) sont transmises afin d'améliorer le rapport signal sur bruit. L'électroacoustique a été caractérisée avec des objets académiques et un hydrophone afin de déterminer les propriétés d'émission du système d'imagerie (réponses impulsionnelles et distribution spatiale du champ) et de développer des outils de correction des données; ces résultats sont mis en regard avec le formalisme de résolution du problème inverse (algorithme de sommation des rétroprojections elliptiques filtrées en champ proche). L'évaluation du système d'imagerie est réalisées sur des objets ponctuels, des objets bidimensionnels à faible contraste d'impédance et un fantôme anthropomorphique de sein contenant des inclusions / Ultrasound computed tomography has considerable potential as a means of breast cancer detection since it reduces the operator-dependency observed in echography. A half-ring transducer array was designed based on the breast anatomy, to obtain reflectivity images of the ductolobular structures using tomographic reconstruction procedures. The 3-MHz transducer array comprises 1024 elements set, in a 190-degree circular arc with a radius of 100 mm. The front-end electronics incorporate 32 independent parallel transmit/receive channels and a 32-to-1024 multiplexer unit. The transmit and receive circuitries have a variable sampling frequency of up to 80 MHz and a 12-bit precision. Arbitrary waveforms are synthesized to improve the signal-to-noise ratio. The set-up was calibrated with academic objects and a needle hydrophone to develop the data correction tools and specify the properties of the system; results are compared with the formalism of inverse problem (elliptical back-projection summation algorithm).The backscattering field was recorded using a restricted aperture, and tomographic acquisitions were performed with a pair of 0.08 mm diameter steel threads, a low contrast 2-D breast phantom, and a breast-shaped phantom containing inclusions. The pulse compression is used and the contribution of this technique to ultrasound computed tomography is evaluated with respect to the use of a standard broadband pulse. Prospects for development of inspection methods and also adaptations of the electroacoustic set-up dedicated to the anatomical tomographic imaging are proposed relative to conducted studies during this thesis.

Page generated in 0.0329 seconds