• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 35
  • 1
  • Tagged with
  • 36
  • 32
  • 26
  • 21
  • 19
  • 16
  • 13
  • 13
  • 9
  • 8
  • 5
  • 5
  • 5
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Reprodutibilidade da curva de pressão intraocular de 24 horas em pacientes com glaucoma e suspeita de glaucoma /

Hashimoto, Mitsuo. January 2015 (has links)
Orientador: Hamilton Almeida Rollo / Coorientador: Maria Rosa Bet de Moraes Silva / Banca: Edson Nacib Jorge / Banca: Ralph Cohen / Banca: José Paulo Cabral de Vasconcellos / Banca: Maria de Lourdes Veronese Rodrigues / Resumo: Foi avaliada a reprodutibilidade das medidas de pressão intraocular (PIO) nos mesmos horários da curva tensional diária (CTD) de 24 horas, com três repetições. Foram estudados 33 indivíduos com glaucoma e suspeita de glaucoma sem tratamento. Todos os participantes foram submetidos a 3 CTDs de 24 horas. Os pacientes foram internados e as medidas foram realizadas às 9:00 hs, 12:00 hs, 15:00 hs, 18:00 hs, 21:00 hs, 24:00 hs e 6:00 hs com tonômetro de aplanação de Goldmann (TAG). A medida das 6:00 hs também foi realizada no leito, utilizando-se um tonômetro manual de Perkins antes da medida com o TAG. Uma segunda CTD de 24 horas foi realizada após um intervalo entre uma e três semanas e uma terceira após mesmo intervalo. A reprodutibilidade foi avaliada em cada horário da CTD de 24 horas com o coeficiente de correlação intraclasse (CCI) e os gráficos de Bland- Altman. Nos gráficos de Bland-Altman considerou-se como limite de concordância uma diferença de até 3 mmHg entre as medidas. O CCI variou de 0,736 a 0,917 nos diferentes horários, estando a maioria deles acima de 0,800. Nos gráficos de Bland- Altman, a porcentagem de pontos dentro do limite de concordância de 3 mmHg variou de 72,7 a 97,0%, sendo na maioria das observações acima de 80%. Concluiuse que as medidas da PIO em cada momento da CTD de 24 horas nas três repetições apresentaram excelente ou boa reprodutibilidade em indivíduos com glaucoma e suspeita de glaucoma / Abstract: The reproducibility of measurements of intraocular pressure (IOP) at the same points of the 24-hour daily tension curve (DTC) with three replications was evaluated. Thirtythree untreated subjects with glaucoma and suspected glaucoma were studied. All participants underwent three 24-hour DTCs. Briefly, participants were hospitalized and IOP measurements obtained at 9:00 AM, noon, 3:00 PM, 6:00 PM, 9:00 PM, midnight and 6:00 AM using a Goldmann applanation tonometer. The 6:00 AM measurement was also obtained at bedside with a handheld Perkins tonometer prior to Goldmann tonometry. A second 24-hour DTC was performed 1 to 3 weeks after the first, and a third and final curve was obtained 1 to 3 weeks after the second. Reproducibility of measurements at each time point of the 24-hour DTC was assessed by means of the intraclass correlation coefficient (ICC) and Bland-Altman plots. A 3-mmHg difference in IOP was defined as the limit of agreement for Bland- Altman plots. ICCs ranged from 0.736 to 0.917 at different time points, with the majority exceeding 0.800. The percentage of points within the 3-mmHg limit of agreement on Bland-Altman plots ranged from 72.7% to 97.0%, exceeding 80% in most cases. In conclusion, in patients with glaucoma or suspected glaucoma, IOP measurements obtained at each time point of the 24-hour DTC showed good or excellent reproducibility across the three curves performed / Doutor
12

Avaliação da pressão intraocular em chinchilas (chinchilla Lanigera) de diferentes faixas etárias utilizando tonometria de rebote

Claros Chacaltana, Flor Diana Yokoay January 2013 (has links)
A aferição da pressão intraocular (PIO) é fundamental durante o exame oftálmico. Objetivou-se estabelecer os valores de referência da PIO de chinchilas de diferentes faixas etárias utilizando o tonômetro de rebote. A PIO foi aferida ao longo do dia às 7, 12 e 19 horas utilizando o tonômetro de rebote (Tonovet®). As chinchilas foram subdivididas em três grupos com 12 animais cada, considerando as idades, designados por GI (animais com idade entre dois a seis meses), GII (com idade entre 20 e 34 meses) e GIII (animais com idade entre 37 e 135 meses). Previamente, foram realizados teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia indireta em todos os animais. O valor médio da pressão intraocular encontrado foi 2,49 ± 0,56 mmHg, os valores médios para o grupo I foi de 2,47±0,581 mmHg, no grupo II de 2,47±0,581 mmHg e no grupo III de 2,51±0,531 mmHg. Não foram encontradas diferenças significativas entre a idade e a PIO (P = 0,756). Não foram encontradas diferenças significativas entre as horas do dia e a PIO (P = 0,415). Não foram encontradas diferenças significativas entre os sexos (P = 0,857). Os valores da PIO em chinchilas não sofrem alterações decorrentes do sexo e da idade dos animais. Não ocorre influência do ritmo circadiano na PIO de chinchilas. / The assessment of intraocular pressure (IOP) is essential for the ocular examination. The purpose of this study was to establish reference values of intraocular pressure chinchillas (Chinchilla lanigera) of different age groups. Thirty-six Chinchillas were divided in three groups of 12 animals each, considering the ages designated by GI (animals aged two to six months), GII (aged between 20 and 34 months) and GIII (animals aged between 37 and 135 months). Intraocular pressure was measured at 7, 12 and 19 hours. Tear production was measured, fluorescein test, slit-lamp biomicroscopy and indirect ophthalmoscopy in all animals and IOP was measured using the rebound tonometer (Tono Vet®) set on the P (undefined species) setting, with measurements obtained from each eye. No abnormalities were found on ophthalmic examination. The mean (±SD) of IOP was 2.49 ± 0.56 mmHg, with a range of 2-4 mmHg. The mean (±SD) of IOP for group I, II and III were 2.47 ± 0.581 mmHg, 2.47 ± 0.581 mmHg and 2,51 ± 0.531 mmHg, respectively. No significant differences were found between age and IOP and no significant differences were found between the hours of day and IOP. No significant differences were found between the genders. The IOP in chinchillas is unchanged between genders and age of the animals. The circadian rhythm is not influenced by IOP in chinchillas.
13

Avaliação de parâmetros tomográficos de córnea e segmento anterior e de variáveis desencadeadas pela resposta ocular à tonometria de não contato / Evaluation of corneal and anterior segment tomography parameters and variables triggered by ocular response to non-contact tonometry

Iris de Souza Yamane 24 July 2012 (has links)
OBJETIVO: avaliar e correlacionar parâmetros tomográficos de segmento anterior e parâmetros biomecânicos de córnea entre si, com a idade e o gênero de pacientes com olhos normais. MÉTODOS: um estudo clínico de série de casos com intervenção diagnóstica foi realizado, envolvendo um olho selecionado aleatoriamente de 235 pacientes (235 olhos). Os pacientes foram submetidos a exame oftalmológico completo, incluindo avaliação tomográfica (Pentacam) e biomecânica (ORA). Parâmetros avaliados pelo Pentacam: K1, K2, K Front Max , Astig, ISV, IVA, KI, CKI, IHA, IHD, BAD D, BAD Df, BAD Db, BAD Dp, BAD Dt, BAD Dy, ART Max, ART Avg, ART Min, Enh BFS Front 8mm, Enh BFS Back 8mm, Ele F BFS 8mm Apex, Ele F BFS 8mm Thinnest, Ele F BFS 8mm Max 4mm zone, Ele B BFS 8mm Apex, Ele B BFS 8mm Thinnest, Ele B BFS 8mm Max 4mm zone, Ele F BFTE 8mm Apex, Ele F BFTE 8mm Thinnest, Ele F BFTE 8mm 4 mm zone, Ele B BFTE 8mm Apex, Ele B BFTE 8mm Thinnest, Ele B BFTE 8mm Max 4mm zone, RPI Max, RPI Avg, RPI Min, Diff RPI Max Compl, Diff RPI Min Compl, Pachy Min, Pachy Apex, Pachy Pupil, Rel Pachy Min, Asph Q Front 30º, Asph Q Back 30º, Q Asymmetr Frontal Hor 30º, Q Asymmetr Frontal Vert 30º, AC Depth, AC Volume, Ch Angle, Volume, PNS, Densid Avg %. Parâmetros avaliados pelo ORA: IOPg, IOPcc, CH, CRF, KC Score, KC Normal, KC Suspect, KC Mild, KC Moderate, KC Severe, WS, aindex, bindex, p1area, p2area, aspect1, aspect2, uslope1, uslope2, dslope1, dslope2, w1, w2, h1, h2, dive1, dive2 , path1, path2, mslew1, mslew2, slew1, slew2, aplhf, p1area1, p2area1, aspect11, aspect21, uslope11, uslope21, dslope11, dslope21, w11, w21, h11, h21, path11, path21. RESULTADOS: K1, K2, K Max Front, BAD Df, Ele B BFS 8mm Thinnest, Ele B BFTE 8mm Thinnest, CRF e CH apresentaram valores mais altos no sexo feminino, enquanto BAD Db, Enh BFS Front 8mm, AC Depth, AC Volume, Ch Angle, p1area, w2, h1, p1area1, w21 e h11 apresentam valores mais altos no sexo masculino. CKI, BAD Db, Ele F BFS 8mm Apex, Ele F BFS 8mm Thinnest, Ele F BFTE 8mm Apex, Ele F BFTE 8mm Thinnest, Asph Q Back 30º, AC Depth, Ch Angle mostraram forte correlação negativa com a idade. Ele B BFS 8mm Apex, Ele B BFS 8mm Thinnest, Ele B BFTE 8mm Apex, Ele B BFTE 8mm Thinnest mostraram forte correlação positiva com a idade. As correlações mais altas de CH e CRF ocorreram com BAD Dt, Pachy Min, Pachy Apex e Pachy Pupil, ou seja, CH e CRF apresentaram associação positiva com a espessura corneana central. As correlações mais altas da IOPg ocorreram com BAD Dt, ART Max, ART Avg, Pachy Min, Pachy Apex e Pachy Pupil mostrando ser afetada pela espessura corneana. A IOPcc mostrou correlações mais baixas do que as obtidas com a IOPg, sendo esta menos afetada pela espessura corneana. CONCLUSÃO: Os parâmetros tomográficos de segmento anterior (Pentacam) e biomecânicos (ORA) mostraram diversas associações estatisticamente significantes entre si com a idade e com o gênero de pacientes com olhos normais / PURPOSE: to evaluate and to correlate anterior segment tomography parameters and corneal biomechanical parameters between each other, age and gender in patients with healthy eyes. METHODS: a clinical study of case series design with diagnostic intervention was conducted, involving one eye randomly selected from 235 patients (235 eyes). Patients underwent complete ophthalmological examination, including tomographic (Pentacam) and biomechanical (ORA) evaluation. Pentacam parameters assesssed: K1, K2, K Front Max , Astig, ISV, IVA, KI, CKI, IHA, IHD, BAD D, BAD Df, BAD Db, BAD Dp, BAD Dt, BAD Dy, ART Max, ART Avg, ART Min, Enh BFS Front 8mm, Enh BFS Back 8mm, Ele F BFS 8mm Apex, Ele F BFS 8mm Thinnest, Ele F BFS 8mm Max 4mm zone, Ele B BFS 8mm Apex, Ele B BFS 8mm Thinnest, Ele B BFS 8mm Max 4mm zone, Ele F BFTE 8mm Apex, Ele F BFTE 8mm Thinnest, Ele F BFTE 8mm 4 mm zone, Ele B BFTE 8mm Apex, Ele B BFTE 8mm Thinnest, Ele B BFTE 8mm Max 4mm zone, RPI Max, RPI Avg, RPI Min, Diff RPI Max Compl, Diff RPI Min Compl, Pachy Min, Pachy Apex, Pachy Pupil, Rel Pachy Min, Asph Q Front 30º, Asph Q Back 30º, Q Asymmetr Frontal Hor 30º, Q Asymmetr Frontal Vert 30º, AC Depth, AC Volume, Ch Angle, Volume, PNS, Densid Avg %. ORA Parameters assessed: IOPg, IOPcc, CH, CRF, KC Score, KC Normal, KC Suspect, KC Mild, KC Moderate, KC Severe, WS, aindex, bindex, p1area, p2area, aspect1, aspect2, uslope1, uslope2, dslope1, dslope2, w1, w2, h1, h2, dive1, dive2 , path1, path2, mslew1, mslew 2, slew1, slew2, aplhf, p1area1, p2area1, aspect11, aspect21, uslope11, uslope21, dslope11, dslope21, w11, w21, h11, h21, path11, path21. RESULTS: K1, K2, K Max Front, BAD Df, Ele B BFS 8mm Thinnest, Ele B BFTE 8mm Thinnest, CRF and CH showed higher values in females and BAD Db, Enh BFS Front 8mm, AC Depth, AC Volume, Ch Angle, p1area, w2, h1, p1area1, w21 and h11 showed higher values in males. CKI, BAD Db, Ele F BFS 8mm Apex, Ele F BFS 8mm Thinnest, Ele F BFTE 8mm Apex, Ele F BFTE 8mm Thinnest, Asph Q Back 30º, AC Depth, Ch Angle showed strong negative correlation with age. Ele B BFS 8mm Apex, Ele B BFS 8mm Thinnest, Ele B BFTE 8mm Apex, Ele B BFTE 8mm Thinnest showed strong positive correlation with age. The highest correlations of CH and CRF occurred with BAD Dt, Pachy Min, Pachy Apex and Pachy Pupil, i.e. CH and CRF presented positive association with central corneal thickness. The highest correlations of IOPg occurred with BAD Dt, ART Max, ART Avg, Pachy Min, Pachy Apex and Pachy Pupil, showing that it is affected by the thickness of the cornea. IOPcc showed lower correlations than those obtained with IOPg, showing that it is less affected by the thickness of the cornea. CONCLUSION: Anterior segment tomographic parameters (Pentacam) and biomechanical parameters (ORA) showed several statistically significant associations between each other, age and gender in patients with healthy eyes
14

Avaliação da pressão intraocular em chinchilas (chinchilla Lanigera) de diferentes faixas etárias utilizando tonometria de rebote

Claros Chacaltana, Flor Diana Yokoay January 2013 (has links)
A aferição da pressão intraocular (PIO) é fundamental durante o exame oftálmico. Objetivou-se estabelecer os valores de referência da PIO de chinchilas de diferentes faixas etárias utilizando o tonômetro de rebote. A PIO foi aferida ao longo do dia às 7, 12 e 19 horas utilizando o tonômetro de rebote (Tonovet®). As chinchilas foram subdivididas em três grupos com 12 animais cada, considerando as idades, designados por GI (animais com idade entre dois a seis meses), GII (com idade entre 20 e 34 meses) e GIII (animais com idade entre 37 e 135 meses). Previamente, foram realizados teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia indireta em todos os animais. O valor médio da pressão intraocular encontrado foi 2,49 ± 0,56 mmHg, os valores médios para o grupo I foi de 2,47±0,581 mmHg, no grupo II de 2,47±0,581 mmHg e no grupo III de 2,51±0,531 mmHg. Não foram encontradas diferenças significativas entre a idade e a PIO (P = 0,756). Não foram encontradas diferenças significativas entre as horas do dia e a PIO (P = 0,415). Não foram encontradas diferenças significativas entre os sexos (P = 0,857). Os valores da PIO em chinchilas não sofrem alterações decorrentes do sexo e da idade dos animais. Não ocorre influência do ritmo circadiano na PIO de chinchilas. / The assessment of intraocular pressure (IOP) is essential for the ocular examination. The purpose of this study was to establish reference values of intraocular pressure chinchillas (Chinchilla lanigera) of different age groups. Thirty-six Chinchillas were divided in three groups of 12 animals each, considering the ages designated by GI (animals aged two to six months), GII (aged between 20 and 34 months) and GIII (animals aged between 37 and 135 months). Intraocular pressure was measured at 7, 12 and 19 hours. Tear production was measured, fluorescein test, slit-lamp biomicroscopy and indirect ophthalmoscopy in all animals and IOP was measured using the rebound tonometer (Tono Vet®) set on the P (undefined species) setting, with measurements obtained from each eye. No abnormalities were found on ophthalmic examination. The mean (±SD) of IOP was 2.49 ± 0.56 mmHg, with a range of 2-4 mmHg. The mean (±SD) of IOP for group I, II and III were 2.47 ± 0.581 mmHg, 2.47 ± 0.581 mmHg and 2,51 ± 0.531 mmHg, respectively. No significant differences were found between age and IOP and no significant differences were found between the hours of day and IOP. No significant differences were found between the genders. The IOP in chinchillas is unchanged between genders and age of the animals. The circadian rhythm is not influenced by IOP in chinchillas.
15

Estudo caso-controle de paquimetria corneana central em indivíduos com catarata congênita e afacia pós-cirúrgica / Central corneal thickness in individuals with congenital cataract and surgical aphakia : a case-control study

Lupinacci, Alvaro Pedroso de Carvalho 17 August 2018 (has links)
Orientador: Vital Paulino Costa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-17T05:07:13Z (GMT). No. of bitstreams: 1 Lupinacci_AlvaroPedrosodeCarvalho_D.pdf: 8725508 bytes, checksum: 4f3d11456e7491230be37c721f4fe7a4 (MD5) Previous issue date: 2010 / Resumo: O presente estudo teve como objetivo medir a espessura corneana central (ECC) de indivíduos com catarata congênita e afacia cirúrgica após extração de catarata congênita. Indivíduos com catarata congênita ou afacia cirúrgica após cirurgia de catarata congênita foram recrutados prospectivamente e divididos em quatro grupos: catarata unilateral (n=14), catarata bilateral (n=18), afacia unilateral (n=32) e afacia bilateral (n=44). Um grupo controle foi selecionado a partir de indivíduos normais pareados por idade, gênero e etnia. Paquimetria ultrassônica foi realizada pelo mesmo observador com o aparelho Micropach 200P+ (Sonomed, Lake Success, Nova Iorque, EUA), após anestesia tópica com uma gota de oxibuprocaína 0,4%. Registrou-se a média de cinco medidas para cada olho. A ECC média do grupo controle (513,57±23,32µm) não foi significativamente diferente da média dos olhos contralaterais normais (526,36±38,52µm) (p=0,747) e dos olhos com catarata (527,00±36,03µm) (p=0,252) do grupo catarata unilateral. A ECC média de ambos os olhos do grupo catarata bilateral (olho direito: 547,69±34,17µm; olho esquerdo: 545,88±36,69µm) foi maior que a observada no grupo controle (olho direito: 516,06±18,66µm; olho esquerdo: 515,53±17,43µm) (p<0,01). A média da ECC dos olhos afácicos (597,25±44,14µm) no grupo afacia unilateral foi significativamente maior que as observadas nos olhos contralaterais saudáveis (523,47±21,42µm) e no grupo controle (511,81±18,81µm) (p<0,001). Ambos os olhos do grupo afacia bilateral apresentaram ECC média (olho direito: 615,75±61,03µm; olho esquerdo: 618,91±61,86µm) significativamente maior que no grupo controle (olho direito: 515,59±18,80µm; olho esquerdo: 515,86±18,51µm) (p<0,001). Observou-se ECC média significativamente maior nos olhos afácicos (uni e bilaterais) que nos olhos com catarata (uni e bilaterais) (p<0,001). Olhos afácicos após extração de catarata congênita apresentam córneas mais espessas que olhos fácicos normais. Olhos afácicos após cirurgia de catarata congênita também apresentam córneas mais espessas que olhos com catarata congênita, sugerindo que o aumento da espessura corneana central ocorra após a cirurgia / Abstract: This study aimed to measure the central corneal thickness (CCT) of patients with congenital cataract and surgical aphakia post congenital cataract extraction. Individuals with congenital cataract or aphakia after surgery for congenital cataract were recruited prospectively and divided into four groups: unilateral cataract (n=14), bilateral cataracts (n=18), unilateral aphakia (n=32) and bilateral aphakia (n=44). A control group was selected from healthy individuals matched for age, gender and ethnicity. Ultrasonic pachymetry was performed by the same observer with the Micropach 200P+ pachymeter (Sonomed, Lake Success, New York, USA) after topical anesthesia with a drop of oxybuprocaine 0.4%. The average of five measurements for each eye was recorded for the analysis. The mean CCT of the control group (513.57±23.32µm) was not significantly different from the contralateral normal eyes (526.36±38.52µm) (p=0.747) and eyes with cataract (527.00±36.03µm) (p=0.252) of the unilateral cataract group. The mean CCTs of both eyes in the bilateral cataract group (right eye: 547.69±34.17µm; left eye: 545.88 ± 36.69µm) were significantly thicker than the observed in the control group (right eye: 516.06±18.66µm; left eye: 515.53±17.43µm) (p<0.01). The mean CCT of aphakic eyes (597.25±44.14µm) in the unilateral aphakia group was significantly thicker than those observed in healthy contralateral eyes (523.47±21.42µm) and the control group (511.81±18.81µm) (p<0.001). Both eyes of the bilateral aphakia group had mean CCT (right eye: 615.75±61.03µm; left eye: 618.91±61.86µm) significantly thicker than the control group (right eye: 515.59±18.80µm; left eye: 515.86±18.51µm) (p<0.001). The mean CCT was significantly thicker in aphakic eyes (unilateral and bilateral) than in eyes with cataract (unilateral and bilateral) (p<0.001). Aphakic eyes after congenital cataract extraction have thicker corneas than normal phakic eyes and eyes with congenital cataract. This suggests that increased central corneal thickness occurs after congenital cataract extraction surgery / Doutorado / Oftalmologia / Doutor em Ciências Médicas
16

Hemodiluição normovolêmica aguda: estudo experimental comparativo utilizando amido hidroxietílico a 6% ou solução de Ringer lactato / Acute normovolemic hemodilution: comparative evaluation with hydroxyethyl starch and Lactated Ringer’s

Denise Aya Otsuki 18 June 2004 (has links)
Hemodiluição normovolêmica aguda é um procedimento utilizado para diminuir a necessidade de transfusões sangüíneas em diversas cirurgias de grande porte. Poucos trabalhos avaliam as alterações hemodinâmicas e perfusão tecidual através de estudo ecocardiográfico e tonometria gástrica. Foram utilizados 23 porcos (peso 46.6 ± 6.0 kg) anestesiados com quetamina, fentanil e propofol e instrumentados para monitorização hemodinâmica convencional. Os animais foram randomizados em três grupos 30 minutos após estabilização da anestesia: Grupo I (Controle), Grupo II (amido hidroxietílico) e Grupo III (Ringer lactato). Os animais do grupo II e III foram submetidos ao protocolo de hemodiluição com hematócrito alvo de 15%. A retirada de sangue foi realizada em 30 minutos e a expansão plasmática feita simultaneamente com amido hidroxietílico ou Ringer lactato nas proporções de 1:1 ou 1:3 em relação ao sangue retirado. Os parâmetros hemodinâmicos e de oxigenação, pH gástrico, ecocardiografia transesofágica (fração de ejeção através do método Simpson) foram coletados antes da hemodiluição (T0), no fim do procedimento de hemodiluição (T1) e após uma e duas horas (T2, T3). Os dados foram submetidos a análise de variância para medidas repetidas, seguida pelo teste Tukey e teste T student. Resultados: Em relação aos parâmetros do grupo controle, não houve diferença significante durante todo o procedimento. No grupo II e grupo III, houve aumento no índice cardíaco após hemodiluição (T0=5,80±1,46; T1=10,64±1,69 L.min-1.m2 e T0=5,53±1,18, T1=7,91±1,40 L.min-1.m2 respectivamente), e diminuição do índice de resistência vascular sistêmica (T0=1753±336, T1=822±140 dina.s.cm-5.m-2 e T0=1673±566, T1=1026±190 dina.s.cm-5.m-2 respectivamente), ambos estatisticamente significante. A fração de ejeção apresentou aumento significativo após a hemodiluição no grupo II. O pH gástrico diminuiu significativamente no grupo III. O lactato arterial aumentou de forma significante no grupo III após a hemodiluição. A microscopia eletrônica do ventrículo esquerdo mostraram discreta destruição de miofilamentos no grupo II. Houve destruição importante nas miofibrilas no grupo III. Conclusão: Estes resultados sugerem que na hemodiluição moderada a grave, o amido hidroxietílico consegue preservar melhor a estabilidade hemodinâmica do que a solução de Ringer lactato. / Normovolemic acute hemodilution is a procedure utilized to decrease the needs of blood transfusion during a variety of surgical procedures. Nevertheless, there are few works that evaluate its pulmonary effects as well as hemodynamic changes by means of echocardiography and tonometric evaluation. Methods: 23 anesthetized pigs (weight 46.6 ± 6.0 kg) were instrumented for standard hemodynamic monitoring. In order to prevent possible effects of inhaled anesthetics on pulmonary mechanics, intravenous anesthesia was chosen and consisted of ketamine, fentanyl and propofol administered throughout the study. Thirty minutes after anesthesia stabilization animals were randomized in three groups: Group I (Control), Group II (hydroxyethyl starch) and Group III (Lactated Ringer’s). Animals of group II and III were submitted to acute normovolemic hemodilution to reach a pre-established hematocrit around 15%. Blood withdrawal was accomplished in thirty minutes and plasma expansion was performed simultaneously with hydroxyethyl starch or Lactated Ringer’s administered in a proportion of 1:1 or 3:1 in relation to the amount of bloods withdrawn. Hemodynamic, gastric pH, transesophageal echography (ejection fraction, by Simpon method) and oxygen transport were measured before blood withdrawal (T0), at the end of hemodilution (T1), one and two hours after the end of hemodilution (T2, T3). Data were submitted to analysis of Variance for repeated measures followed by the Tukey test and also to a student T test. Results: In regard to all parameters of Group I (Control), there were no significant difference during the whole procedure. In Group II and Group III, there was an increase in cardiac index after hemodilution (T0=5.80±1.46; T1=10.64±1.69 L.min-1.m2 and T0=5.53±1.18, T1=7.91±1.40 L.min-1.m2), and a decrease in systemic vascular resistance index (T0=1753±336, T1=822±140 dyne.s.cm-5.m-2 and T0=1673±566, T1=1026±190 dyne.s.cm-5.m-2), both statistically significant. Ejection Fraction increased significantly after hemodilution in group II. Gastric pH decreased significantly in Group III, and arterial lactate increased significantly after hemodilution in group III. Electron microscopy of left ventricular bipsies showed a slight destruction in filament and preserved myofibrillar ultrastructure in group II. There was important destruction in myofibrillar ultrastructure in group III. Conclusion: These results suggest that in severe hemodilution, hydroxyethyl starch preserves hemonodynamic stability better than Lactate Ringer’s.
17

Curva diária de pressão intraocular em porquinhos da índia (Cavia porcellus) de diferentes faixas etárias com tonometria de rebote

Ghiggi, Eduardo January 2016 (has links)
A aferição da pressão intraocular (PIO) é essencial para o exame oftálmico. Objetivou-se estabelecer os valores da curva diária da PIO de porquinhos da índia de diferentes faixas etárias com tonômetro de rebote. A PIO foi aferida às 6, 12, 18 e 24 horas utilizando o tonômetro de rebote (Tonovet®). Os porquinhos da índia foram subdivididos em dois grupos com 10 animais no grupo I e 4 animais no grupo II, considerando as idades, designados por GI (animais entre 2 a 3 meses de idade) e GII (animais entre 2 a 3 anos de idade). Previamente, foram realizados teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia indireta em todos animais. O valor médio da pressão intraocular foi de 12,0 ± 1,83 mmHg. Foram encontradas diferenças significativas entres as idades, sendo que os valores médios para o grupo I foram 11,63 ± 0,29 mmHg, e para o grupo II foram 12,82 ± 0,45mmHg (P= 0,0295). Não foram encontradas diferenças entre ambos os olhos (P= 0,7454). Não foram encontradas diferenças significativas nos valores da PIO relacionadas ao sexo (P= 0,1858). Os valores da PIO em porquinhos da índia tiveram alteração nas horas avaliadas. Com base nos resultados obtidos foi possível concluir que os valores da PIO em porquinhos da índia da sofrem alterações ao longo do dia. Os menores valores de pressão intraocular ocorreram às 18 horas. / The measuring of intraocular pressure (IOP) it is essential for the ophthalmic evaluation; the aim of this study was establish the values of the IOP diurnal curve of guinea pigs with different ages using the rebound tonometer (Tonovet®). The animals were divided according to the age in two groups, Group I (GI) constituted with 10 guinea pigs aged between 2 -3 moths, and Group II (GII), 4 animals with 2 -3 years of old. Previously the Schirmer tear test, fluorescein test, biomicroscopy with slit lamp, and direct optalmoscopy were performed on all animals. The men value of IOP was 12.0±0.34 mmHg. Statistical difference were found between ages (mean GI 11.64 ± 0.29 mmHg, and GII 12.83 ± 0.45mmHg), did not have statistical difference related with gender (P= 0.1858) or between eyes (P= 0.7454). In conclusion the guinea pigs had alteration of IOP true the day, the values of IOP are higher in the morning period, decrease true the day and at the night period haves an elevation again.
18

Curva diária de pressão intraocular em porquinhos da índia (Cavia porcellus) de diferentes faixas etárias com tonometria de rebote

Ghiggi, Eduardo January 2016 (has links)
A aferição da pressão intraocular (PIO) é essencial para o exame oftálmico. Objetivou-se estabelecer os valores da curva diária da PIO de porquinhos da índia de diferentes faixas etárias com tonômetro de rebote. A PIO foi aferida às 6, 12, 18 e 24 horas utilizando o tonômetro de rebote (Tonovet®). Os porquinhos da índia foram subdivididos em dois grupos com 10 animais no grupo I e 4 animais no grupo II, considerando as idades, designados por GI (animais entre 2 a 3 meses de idade) e GII (animais entre 2 a 3 anos de idade). Previamente, foram realizados teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia indireta em todos animais. O valor médio da pressão intraocular foi de 12,0 ± 1,83 mmHg. Foram encontradas diferenças significativas entres as idades, sendo que os valores médios para o grupo I foram 11,63 ± 0,29 mmHg, e para o grupo II foram 12,82 ± 0,45mmHg (P= 0,0295). Não foram encontradas diferenças entre ambos os olhos (P= 0,7454). Não foram encontradas diferenças significativas nos valores da PIO relacionadas ao sexo (P= 0,1858). Os valores da PIO em porquinhos da índia tiveram alteração nas horas avaliadas. Com base nos resultados obtidos foi possível concluir que os valores da PIO em porquinhos da índia da sofrem alterações ao longo do dia. Os menores valores de pressão intraocular ocorreram às 18 horas. / The measuring of intraocular pressure (IOP) it is essential for the ophthalmic evaluation; the aim of this study was establish the values of the IOP diurnal curve of guinea pigs with different ages using the rebound tonometer (Tonovet®). The animals were divided according to the age in two groups, Group I (GI) constituted with 10 guinea pigs aged between 2 -3 moths, and Group II (GII), 4 animals with 2 -3 years of old. Previously the Schirmer tear test, fluorescein test, biomicroscopy with slit lamp, and direct optalmoscopy were performed on all animals. The men value of IOP was 12.0±0.34 mmHg. Statistical difference were found between ages (mean GI 11.64 ± 0.29 mmHg, and GII 12.83 ± 0.45mmHg), did not have statistical difference related with gender (P= 0.1858) or between eyes (P= 0.7454). In conclusion the guinea pigs had alteration of IOP true the day, the values of IOP are higher in the morning period, decrease true the day and at the night period haves an elevation again.
19

Estudo comparativo entre a tonometria de rebote e a tonometria de aplanação em equinos da raça crioula (Equus cabbalus)

Andrade, Maria Cristina Caldart de January 2011 (has links)
A aferição da pressão intraocular (PIO) é importante para o diagnóstico e acompanhamento de doenças oculares. Métodos fidedignos para quantificar a PIO de maneira acurada têm sido buscados. Com o aparecimento de tonômetros portáteis, a avaliação da pressão intraocular em equinos tem se intensificado e os diferentes princípios de aferição têm sido comparados. Este estudo objetivou a comparação entre a tonometria de aplanação, realizada com o Tono-Pen Avia®, e tonometria de rebote, realizada com o Tonovet®, em equinos da raça Crioula. Além disso, a utilização, ou não, do cachimbo como método de contenção também foi comparada e submetida à análise estatística. Foram avaliados 30 cavalos com idades entre dois e 20 anos, machos ou fêmeas. Exame oftálmico prévio foi realizado com teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia direta. A tonometria de aplanação foi realizada, no mínimo, 30 minutos após a tonometria de rebote. A pressão intraocular média do Tonovet® foi maior, 36,82 ± 5,91mmHg com cachimbo e 30,04 ± 3,19mmHg sem. A do Tono-Pen Avia® foi de 26,43 ± 5,48 mmHg com cachimbo e 23,10 ±4,01mmHg sem. Todos os resultados diferiram estatisticamente entre si. Quando comparados os sexos, o Tono-Pen Avia® não mostrou diferenças, enquanto o Tonovet® mostrou pressões maiores para cavalos castrados e garanhões, e menores para éguas (p<0,001) com a utilização do cachimbo. Não há correlação entre a idade dos cavalos e os valores de PIO, independente do aparelho (p > 0,05). Os valores da PIO com o Tonovet® foram maiores do que os obtidos com o Tono-Pen Avia®. A contenção dos animais com cachimbo eleva a pressão intraocular em equinos. / Intraocular pressure evaluation is important for diagnosis and control of ophthalmic diseases. Accurate methods to quantify intraocular pressure have been searched. With the development of handheld tonometers, equine intraocular pressure evaluation has been intensified and the different principles of measurement have been compared. The objective of this study was to compare the applanation tonometry, taken with the Tono- Pen Avia® and the rebound tonometry, taken with the Tonovet® in adult “crioulo” breed horses. The age, gender and the use of upper lip twitch as a restraint method was also surveyed and submitted to statistical analysis. Thirty horses, aged two to 20, male or female were evaluated. A previous ophthalmic examination was performed with Schirmer tear test, fluoresceine test, slit lamp biomicroscopy and direct ophthalmoscopy in all animals. Applanation tonometry was performed, at least, 30 minutes after rebound tonometry. Intraocular pressure mean values measured with the Tonovet® was higher, 36,82±5,91mmHg with the lip twitch and 30,04±3,19mmHg without. Tonopen Avia® mean values were 26,43±5,48mmHg with the lip twitch and 23,10±4,1mmHg without. All results was statistical different between themselves. When genders were compared the Tono-Pen Avia® revealed no difference, however the Tonovet® showed higher pressures for male horses (p‹0,001) with the use of lip twitch. There was no correlation between age and intraocular pressure in “crioulo” horses, regardless of the equipment tested (p›0,05). Intraocular pressure mean values measured with the Tonove®t were higher than those obtained with the Tono-Pen Avia®. The restraint of animals with upper lip twitch increases equine intraocular pressure.
20

Pressão intra-ocular em pré-termos de muito baixo peso de nascimento e sua relação com a idade pós-concepção

Lindenmeyer, Rodrigo Leivas January 2012 (has links)
Objetivo: medir a pressão intra-ocular (PIO) em pré-termos de muito baixo peso (PMBP) e correlacionar com a idade pós-concepção (IPC). Métodos: Estudo longitudinal incluindo 50 pré-termos. Local: Hospital de Clínicas de Porto Alegre. Período: entre novembro de 2008 e junho de 2010. Pacientes: PMBP definido como idade nascimento ≤ 1.500 g e idade gestacional ≤ 32 semanas. Intervenção: medidas semanais da PIO. Principais desfechos: variação da PIO de acordo com a idade pós-concepção (IPC definida como a idade gestacional ao nascimento mais a idade no momento do exame) nas semanas seguintes ao nascimento pré-termo. Análise estatística: modelos de efeitos mistos foram utilizados para determinar a variação da PIO em relação a IPC. Foram calculados as médias e os percentis 10 e 90 (P10 e P90) para os valores da PIO. Resultados: Cinqüenta PMBP com idade gestacional média de 29,7 ± 1,6 semanas e peso de nascimento de 1.127,7 ± 222,7 gramas foram avaliados. Não houve diferença significativa entre a PIO do olho direito e do olho esquerdo (p=0.177). A média da PIO em toda a coorte, considerando ambos os olhos, foi de 14,9 ± 4,5 mmHg, sendo que 13,5% das medidas isoladas da PIO foram superiores a 20 mmHg. A PIO reduziu em média 0,29 mmHg para cada aumento de uma semana da IPC (p=0.047 IC95%: -0,58 a -0,0035). A PIO média (P10-P90) reduziu de 16,3 mmHg (10,52-22,16) com 26,3 semanas de IPC para 13,1 mmHg (7,28-18,92) com 37,6 semanas de IPC. Conclusões: A PIO média em PMBP foi 14,9 ± 4,5 mmHg e apresentou correlação negativa em relação a idade pós-concepção. / Purpose: To measure intraocular pressure (IOP) in very low birth weight preterm infants and correlate it with the postconceptional age (PCA). Methods: Longitudinal study including 50 premature infants. Setting: Hospital de Clinicas de Porto Alegre, Brazil. Patients: Very low birth weight premature infants (defined as birth weight ≤1,500 g and gestational age ≤32 weeks). Intervention: Weekly measurements of the IOP. Main outcomes: The variation of IOP according to the postconceptional age (PCA defined as the gestational age at birth plus the age in weeks at the time of examination) in the weeks following preterm birth. Statistics: Mixed-effects models were used for the statistical analysis to determine IOP variation according to PCA. Means, 10th and 90th percentiles were calculated for IOP values. Results: Fifty preterm infants with a mean gestational age of 29.7 ± 1.6 weeks and mean birth weight of 1,127.7 ± 222.7 grams were evaluated. Mean IOP in the whole cohort considering both eyes was 14.9 ± 4.5 mmHg, and 13.5% of the IOP measurement values were greater than 20 mmHg. The analysis revealed a mean IOP reduction of 0.29 mmHg for each increase of PCA (p=0.047; 95% CI, -0.58 to -0.0035). Mean IOP (P10- P90) decreased from 16.3 mmHg (10.52-22.16) at 26.3 weeks PCA to 13.1 mmHg (7.28- 18.92) at 37.6 weeks PCA. Conclusions: Mean IOP in very low birth weight preterm infants was 14.9 ± 4.5 mmHg and was negatively correlated with PCA.

Page generated in 0.058 seconds