• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 59
  • Tagged with
  • 59
  • 59
  • 38
  • 19
  • 14
  • 14
  • 11
  • 10
  • 9
  • 9
  • 8
  • 8
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Estudo experimental de escoamento pulsátil através de biopróteses valvulares cardíacas mitrais a partir do desenvolvimento de um simulador do lado esquerdo do coração. / Experimental study pulsatile flow through mitral heart bioprosthesis based on the development of a left human heart cardiac simulator.

Bazan, Ovandir 26 March 2014 (has links)
Uma vez que a maioria das complicações relacionadas ao funcionamento das próteses de válvulas cárdicas é devida aos distúrbios de escoamento, a sua caracterização hidrodinâmica é um auxílio útil no projeto de novas válvulas. Simulações do escoamento pulsátil através de próteses de válvulas cardíacas começaram há cerca de 60 anos, por meio do desenvolvimento de diferentes simuladores cardíacos, melhorando a interpretação dos resultados clínicos. Para o presente estudo, um simulador cardíaco foi desenvolvido completamente na Escola Politécnica da Universidade de São Paulo, no Departamento de Engenharia Mecânica, para estudar o fluxo através de próteses mitrais e aórticas. A sua concepção é baseada na geometria e na fisiologia do lado esquerdo do coração humano, no estado da arte desses simuladores e na norma ISO 584:2010. Neste trabalho, o simulador cardíaco desenvolvido foi aplicado para estudar experimentalmente o fluxo pulsátil através de próteses cardíacas mitrais biológicas de pericárdio bovino. Para tanto, após a validação do simulador para algumas freqüências cardíacas, as biopróteses foram submetidas a ensaios de velocimetria não invasiva, por meio de um equipamento Particle Image Velocimetry (PIV). Os experimentos, que se concentraram principalmente logo após o começo da diástole, mostraram qualitativamente uma diferença significativa no escoamento intraventricular em função de dois posicionamentos das biopróteses, defasadas entre si de 180º no sentido do seu eixo longitudinal. Além disso, produziram significativas mudanças no escoamento próximo à prótese aórtica considerada. Com a continuidade deste estudo, os resultados poderão induzir a um dado procedimento clínico. / Since most complications related to the operation of prosthetic heart valves are due to disturbances of flow, their hydrodynamic characterization is a useful aid in the design of new prostheses. Simulations of pulsatile flow in cardiac prostheses began nearly 60 years ago, through the development of different mock human circulatory systems, improving the clinical results interpretation. A complete design of a cardiac simulator was developed at Polytechnic School of USP, Mechanical Engineering Department, to study mitral and aortic prosthetic heart valves. The simulator design is based on the both geometry and physiology of the left side of the human heart, on state-of-art studies and also considering the ISO 584:2010 standard. The cardiac simulator was applied to pulsatile flow testing of bovine pericardium mitral prosthetic valves. For this, after the cardiac simulator validation for some heart rates, the bioprostheses were assayed by noninvasive velocimetry technics, i.e., a Particle Image Velocimetry (PIV) system. The testing, which mainly were focused on just after the beginning of diastole, qualitatively have showed a significant difference in the intraventricular flow according two different positions for the bioprostheses, dephased of 180° in the direction of their longitudinal axis. Moreover, they produced significant changes in flow close to the aortic prosthesis considered. Future works may lead to a particular medical procedure.
22

Avaliação anatômica comparativa da valva mitral e da valva aórtica de corações normais e com cardiomiopatia dilatada isquêmica e idiopática / Comparative anatomical evaluation of the mitral valve and aortic valve of normal hearts and with ischemic and idiopathic dilated cardiomyopathy

Caldas, Guilherme Martins Marrelli 19 December 2006 (has links)
O objetivo deste trabalho foi estudar e comparar a valva mitral e a valva aórtica e em corações com cardiomiopatia dilatada (CMD) de etiologia isquêmica e idiopática, em relação aos corações humanos normais, buscando identificar variações que possam auxiliar em diagnósticos por imagem e para o tratamento cirúrgico das mesmas. Este estudo analisou 22 corações normais, 15 corações dilatados de etiologia isquêmica e 15 corações dilatados de etiologia idiopática, fixados em formaldeído a 10%. Foram obtidas medidas por meio de fotografias digitais dos corações e, posteriormente, utilizando-se software, foram analisados as distâncias e os perímetros da valva mitral e da valva aórtica, que foram comparadas por meio de testes estatísticos. Nos corações normais, a área da valva mitral foi de 5,44 ± 0,82 cm2 e o perímetro de 8,91 ± 0,57 cm, e nos corações com CMD de etiologia isquêmica e idiopática, a área foi de, respectivamente, 7,38 ± 1,76 cm2 e 7,03 ± 1,44 cm2, e o perímetro foi de, respectivamente, 10,41 ± 1,37 cm e 9,97 ± 1,23 cm. O perímetro de inserção da cúspide anterior da valva mitral, nos corações normais, foi de 3,68 ± 0,52 cm e nos corações com CMD de etiologia isquêmica e idiopática foi de, respectivamente, 3,99 ± 0,86 cm e 3,62 ± 0,78 cm. A menor distância perimetral entre os trígonos fibrosos (porção fibrosa), nos corações normais, foi de 2,06 ± 0,26 cm e nos corações com CMD de etiologia isquêmica e idiopática foi de, respectivamente, 2,64 ± 0,37 cm e 2,34 ± 0,37 cm. Nos corações normais, a área da valva aórtica foi de 3,46 ± 0,66 cm2 e o perímetro de 6,83 ± 0,66 cm. Nos corações com CMD de etiologia isquêmica e idiopática, a área da valva aórtica foi de, respectivamente, 5,22 ± 1,53 cm2 e 3,44 ± 1,33 cm2, e o perímetro de, respectivamente, 8,26 ± 1,24 cm e 6,82 ± 1,37 cm. Nos casos de CMD idiopática e isquêmica, a valva mitral apresentava-se aumentada, tanto na sua área e em seu perímetro, quanto na maior e na menor distância perimetral entre os trígonos fibrosos. Em relação à valva aórtica, apenas nos corações com CMD isquêmica houve aumento estatisticamente significante em sua área e em seu perímetro, enquanto que nos corações com CMD idiopática não houve diferença quando comparados aos corações normais. Há manutenção da proporcionalidade, dos corações normais para os com CMD idiopática e isquêmica, das distâncias entre os trígonos fibrosos. Há evidência de que o aumento da valva mitral e da valva aórtica, quando ocorrem na CMD, se dão de forma independente. / The objective of this work was to study and to compare mitral valve as well as aortic valve in the ischemic and idiopathic dilated cardiomyopathy (CMD) in relation to the normal hearts, searching to identify variations that can assist in diagnostic for image and for the surgical treatment of the same ones. This study it analyzed 22 normal hearts, 15 dilated hearts of ischemic etiology and 15 dilated hearts of idiopathic etiology, fixed in formaldehyde 10%. They had been gotten measured through digitalized photographs of the hearts, and, through software, the distances and perimeters of the mitral valve and of the aortic valve had been analyzed, that later they had been compared through statistical tests. In the normal hearts, the area the mitral valve was 5.44 ± 0.82 cm2 and the perimeter of 8.91 ± 0.57 cm. In the hearts with ischemic and idiopathic CMD the area of the mitral valve were, respectively, 7.38 ± 1.76 cm2 and 7.03 ± 1.44 cm2, and to the perimeter it were, respectively, 10.41 ± 1.37 cm and 9.97 ± 1.23 cm. The perimeter of insertion of anterior cusp of mitral valve in the normal hearts was 3.68 ± 0.52 cm, in the hearts with ischemic and idiopathic CMD were, respectively, 3.99 ± 0.86 cm and 3.62 ± 0.78 cm. The lesser length enter the fibrous trigones (fibrous portion) in the normal hearts was 2.06 ± 0.26 cm and in the hearts with ischemic and idiopathic CMD were, respectively, 2.64 ± 0.37 cm and 2.34 ± 0.37 cm In the normal hearts the area of aortic valve was 3.46 ± 0.66 cm2 and the perimeter of 6.83 ± 0.66 cm. In the hearts with ischemic and idiopathic CMD the area of aortic valve were, respectively, 5.22 ± 1.53 cm2 and 3.44 ± 1.33 cm2, and the perimeter of, respectively, 8.26 ± 1.24 cm and 6.82 ± 1.37 cm. In the cases of idiopathic and ischemic CMD, mitral valve is presented increased, as much in its area and its perimeter, how much in the greater and the lesser perimetral distance between the fibrous trigones. In relation to aortic valve, only in the hearts with Ischemic CMD it had significant statistic increase in its area and its perimeter, whereas in the hearts with Idiopathic CMD it did not have difference when compared with the normal hearts. It has maintenance of the proportionality, the normal hearts for the ones with idiopathic and ischemic CMD, of the distances between the fibrous trigones. It has evidence of that the increase of mitral valve and aortic valve, when they occur in the CMD, occurs of independent form.
23

Estudo anatômico do aparelho subvalvar da valva atrioventricular esquerda de corações humanos / Anatomic study of the subvalvar apparatus of the left atrioventricular valve in human hearts

Almeida, Antonio Flávio Sanchez de 26 August 2008 (has links)
Este estudo foi desenvolvido com a intenção de propor uma classificação anatômica atualizada para o aparelho subvalvar da valva atrioventricular esquerda de corações humanos. A classificação de Pomerantzeff foi desenvolvida utilizando nomes lógicos e correlatos, baseada na posição anatômica do coração, e tem uma inovação: a identificação de uma nova estrutura anatômica, o músculo papilar basal. Cinqüenta valvas atrioventriculares esquerdas de corações humanos normais foram examinadas através de incisões realizadas na parede do ventrículo esquerdo. Foram analisados o tipo, a quantidade e a extensão das cordas, seus locais de origem e de inserção. Foi identificada a presença de três conjuntos de cordas: aposicional, basal e central. As cordas aposicionais são divididas em três subgrupos: mural, aórtico e comissural. Esses subgrupos se originam respectivamente nas cabeças mural, aórtica e comissural dos músculos papilares clássicos, aqui denominados superior-esquerdo e inferior-direito, e se inserem na região aposicional dos folhetos mural e aórtico da valva mitral e das suas comissuras superior-esquerda e inferiordireita. O conjunto de cordas basal pode ter três locais de origem: nas cabeças murais dos músculos papilares superior-esquerdo e inferior-direito ou em um músculo papilar acessório, nomeado músculo papilar basal. As cordas basais inserem-se próximas da base de implantação do folheto mural no anel valvar mitral. O terceiro conjunto é constituído pelas cordas centrais, que se originam nas cabeças aórticas dos músculos papilares superioresquerdo e inferior-direito e se implantam na porção central do folheto aórtico da valva mitral. Em cada conjunto podem ser encontrados até quatro tipos de cordas: primárias, secundárias, terciárias e quaternárias. As primárias são aquelas que têm sua origem nas pontas dos músculos papilares. As secundárias são ramificações das primárias, as terciárias são ramificações das secundárias e as quaternárias são ramificações das terciárias. Essa classificação, clara e objetiva, permite fácil reconhecimento das estruturas e pode ser utilizada igualmente por anatomistas, cirurgiões cardiovasculares e médicos que realizam exames diagnósticos por imagem / The aim of this study was proposing an anatomic and present classification of the subvalvar apparatus of the left atrioventricular valve in normal human hearts. Pomerantzeffs classification uses logic and correlated names, the anatomic position of the heart, and has an innovation: the identification of a new anatomic structure, the basal papillary muscle. Fifty left atrioventricular valves of normal human hearts were examined via incisions in the left ventricle wall, visualizing the valve from below. The type, quantity and length of the chordae tendineae and their places of origin and insertion were analyzed. Was identified the presence of three groups of chordae tendineae: appositional, basal and central. The appositional group is divided in three subgroups: mural, aortic and comissural, that arise from the respective heads mural, aortic and comissural of the classic papillary muscles here named leftsuperior and right- inferior and has his insertion in the appositional portion of the mural and aortic leaflets of the mitral valve and in the commissures leftsuperior and right-inferior. The basal group of cords can have three places of origin: from the mural heads of the left-superior and right-inferior papillary muscles or from an accessory papillary muscle, named basal papillary muscle, and as his insertion near of the base of implantation of the mural leaflet in the valvar ring. The central group of cords arises from the aortic heads of the classic papillary muscles and has his insertion in the central portion of the aortic leaflet of the mitral valve. In each group described above there are four types of cordae tendineae: primary (arise from the papillary muscles), secondary (ramification of primary), tertiary (ramification of secondary) and quaternary (ramification of tertiary). This classification, clear and objective, allows easy recognition of the subvalvar structures and can be used equally by anatomists, cardiovascular surgeons and physicians who carry out exams with image diagnostic methods
24

Estudo anatômico do aparelho subvalvar da valva atrioventricular esquerda de corações humanos / Anatomic study of the subvalvar apparatus of the left atrioventricular valve in human hearts

Antonio Flávio Sanchez de Almeida 26 August 2008 (has links)
Este estudo foi desenvolvido com a intenção de propor uma classificação anatômica atualizada para o aparelho subvalvar da valva atrioventricular esquerda de corações humanos. A classificação de Pomerantzeff foi desenvolvida utilizando nomes lógicos e correlatos, baseada na posição anatômica do coração, e tem uma inovação: a identificação de uma nova estrutura anatômica, o músculo papilar basal. Cinqüenta valvas atrioventriculares esquerdas de corações humanos normais foram examinadas através de incisões realizadas na parede do ventrículo esquerdo. Foram analisados o tipo, a quantidade e a extensão das cordas, seus locais de origem e de inserção. Foi identificada a presença de três conjuntos de cordas: aposicional, basal e central. As cordas aposicionais são divididas em três subgrupos: mural, aórtico e comissural. Esses subgrupos se originam respectivamente nas cabeças mural, aórtica e comissural dos músculos papilares clássicos, aqui denominados superior-esquerdo e inferior-direito, e se inserem na região aposicional dos folhetos mural e aórtico da valva mitral e das suas comissuras superior-esquerda e inferiordireita. O conjunto de cordas basal pode ter três locais de origem: nas cabeças murais dos músculos papilares superior-esquerdo e inferior-direito ou em um músculo papilar acessório, nomeado músculo papilar basal. As cordas basais inserem-se próximas da base de implantação do folheto mural no anel valvar mitral. O terceiro conjunto é constituído pelas cordas centrais, que se originam nas cabeças aórticas dos músculos papilares superioresquerdo e inferior-direito e se implantam na porção central do folheto aórtico da valva mitral. Em cada conjunto podem ser encontrados até quatro tipos de cordas: primárias, secundárias, terciárias e quaternárias. As primárias são aquelas que têm sua origem nas pontas dos músculos papilares. As secundárias são ramificações das primárias, as terciárias são ramificações das secundárias e as quaternárias são ramificações das terciárias. Essa classificação, clara e objetiva, permite fácil reconhecimento das estruturas e pode ser utilizada igualmente por anatomistas, cirurgiões cardiovasculares e médicos que realizam exames diagnósticos por imagem / The aim of this study was proposing an anatomic and present classification of the subvalvar apparatus of the left atrioventricular valve in normal human hearts. Pomerantzeffs classification uses logic and correlated names, the anatomic position of the heart, and has an innovation: the identification of a new anatomic structure, the basal papillary muscle. Fifty left atrioventricular valves of normal human hearts were examined via incisions in the left ventricle wall, visualizing the valve from below. The type, quantity and length of the chordae tendineae and their places of origin and insertion were analyzed. Was identified the presence of three groups of chordae tendineae: appositional, basal and central. The appositional group is divided in three subgroups: mural, aortic and comissural, that arise from the respective heads mural, aortic and comissural of the classic papillary muscles here named leftsuperior and right- inferior and has his insertion in the appositional portion of the mural and aortic leaflets of the mitral valve and in the commissures leftsuperior and right-inferior. The basal group of cords can have three places of origin: from the mural heads of the left-superior and right-inferior papillary muscles or from an accessory papillary muscle, named basal papillary muscle, and as his insertion near of the base of implantation of the mural leaflet in the valvar ring. The central group of cords arises from the aortic heads of the classic papillary muscles and has his insertion in the central portion of the aortic leaflet of the mitral valve. In each group described above there are four types of cordae tendineae: primary (arise from the papillary muscles), secondary (ramification of primary), tertiary (ramification of secondary) and quaternary (ramification of tertiary). This classification, clear and objective, allows easy recognition of the subvalvar structures and can be used equally by anatomists, cardiovascular surgeons and physicians who carry out exams with image diagnostic methods
25

Estudo experimental de escoamento pulsátil através de biopróteses valvulares cardíacas mitrais a partir do desenvolvimento de um simulador do lado esquerdo do coração. / Experimental study pulsatile flow through mitral heart bioprosthesis based on the development of a left human heart cardiac simulator.

Ovandir Bazan 26 March 2014 (has links)
Uma vez que a maioria das complicações relacionadas ao funcionamento das próteses de válvulas cárdicas é devida aos distúrbios de escoamento, a sua caracterização hidrodinâmica é um auxílio útil no projeto de novas válvulas. Simulações do escoamento pulsátil através de próteses de válvulas cardíacas começaram há cerca de 60 anos, por meio do desenvolvimento de diferentes simuladores cardíacos, melhorando a interpretação dos resultados clínicos. Para o presente estudo, um simulador cardíaco foi desenvolvido completamente na Escola Politécnica da Universidade de São Paulo, no Departamento de Engenharia Mecânica, para estudar o fluxo através de próteses mitrais e aórticas. A sua concepção é baseada na geometria e na fisiologia do lado esquerdo do coração humano, no estado da arte desses simuladores e na norma ISO 584:2010. Neste trabalho, o simulador cardíaco desenvolvido foi aplicado para estudar experimentalmente o fluxo pulsátil através de próteses cardíacas mitrais biológicas de pericárdio bovino. Para tanto, após a validação do simulador para algumas freqüências cardíacas, as biopróteses foram submetidas a ensaios de velocimetria não invasiva, por meio de um equipamento Particle Image Velocimetry (PIV). Os experimentos, que se concentraram principalmente logo após o começo da diástole, mostraram qualitativamente uma diferença significativa no escoamento intraventricular em função de dois posicionamentos das biopróteses, defasadas entre si de 180º no sentido do seu eixo longitudinal. Além disso, produziram significativas mudanças no escoamento próximo à prótese aórtica considerada. Com a continuidade deste estudo, os resultados poderão induzir a um dado procedimento clínico. / Since most complications related to the operation of prosthetic heart valves are due to disturbances of flow, their hydrodynamic characterization is a useful aid in the design of new prostheses. Simulations of pulsatile flow in cardiac prostheses began nearly 60 years ago, through the development of different mock human circulatory systems, improving the clinical results interpretation. A complete design of a cardiac simulator was developed at Polytechnic School of USP, Mechanical Engineering Department, to study mitral and aortic prosthetic heart valves. The simulator design is based on the both geometry and physiology of the left side of the human heart, on state-of-art studies and also considering the ISO 584:2010 standard. The cardiac simulator was applied to pulsatile flow testing of bovine pericardium mitral prosthetic valves. For this, after the cardiac simulator validation for some heart rates, the bioprostheses were assayed by noninvasive velocimetry technics, i.e., a Particle Image Velocimetry (PIV) system. The testing, which mainly were focused on just after the beginning of diastole, qualitatively have showed a significant difference in the intraventricular flow according two different positions for the bioprostheses, dephased of 180° in the direction of their longitudinal axis. Moreover, they produced significant changes in flow close to the aortic prosthesis considered. Future works may lead to a particular medical procedure.
26

Efeito da correção cirúrgica nas variáveis do teste cardiopulmonar de exercício em pacientes com insuficiência mitral crônica. / Effect of surgical correction on cardiopulmonary exercise testing in patients with organic mitral regurgitation.

Dorival Júlio Della Togna 09 May 2012 (has links)
Introdução: A Insuficiência Mitral (IM) crônica orgânica tem fisiopatologia complexa. Os sintomas de insuficiência cardíaca e piora da capacidade funcional, podem aparecer apenas tardiamente, quando já existe disfunção contrátil do ventrículo esquerdo (VE). O teste cardiopulmonar de exercício (TCPE) pode avaliar objetivamente a capacidade funcional e auxiliar a conduta médica nos pacientes com IM, mas, pouco se conhece sobre o efeito da cirurgia em suas variáveis. Objetivos: Avaliar os efeitos da correção cirúrgica da IM nas variáveis do TCPE realizados em bicicleta e em esteira rolante. Métodos: Foram selecionados 72 pacientes com IM grave e submetidos à cirurgia corretiva da valvopatia, sendo nestes realizados ecocardiograma (ECO) e TCPE ± 30 dias antes da cirurgia, e de seis a 12 meses após a cirurgia. Resultados: A média das idades foi de 49,9 ± 16,9 anos. Houve predominância do sexo masculino, da etiologia degenerativa e da classe funcional I ou II pela NYHA em 41 pacientes (56,9%), 50 pacientes (69,4%) e 51 pacientes (70,8%), respectivamente. O reparo mitral foi realizado em 47 pacientes (65,3%) e a troca valvar em 25 pacientes. Após a cirurgia houve redução do volume atrial esquerdo (VAE), de 124,4 ± 58,9 ml para 76,4 ± 34,0 ml (p<0,001), do volume diastólico final do VE (VDFVE), de 151,7 ± 35,7ml para 109,6 ± 42,8 ml (p<0,001), do volume sistólico final do VE (VSFVE), de 47,6 ± 18,0 para 43,9 ± 27,1ml (p<0,001), da fração de ejeção (FE), de 69,1 ± 6,3 para 61,30 ± 8,2% (p<0,001) e da pressão sistólica em artéria pulmonar (PSAP), de 46,7 ± 15,9 para 35,4 ± 12,5 mm Hg (p<0,001). Também foi observado uma diminuição do consumo de oxigênio (VO2) pico em ambas as modalidades de exercício após a cirurgia (bicicleta: de 1356 ± 506 para 1269 ± 408 mL.min-1, p=0,015; esteira: de 1618 ± 579 para 1536 ± 447 mL.min-1, p=0,06), assim como a variável OUES (bicicleta: de 1530 ± 516 para 1414 ± 415, p=0,001; esteira: de 1761 ± 585 para 1691 ± 508, p=0,050). O pulso de oxigênio (O2) aumentou após a cirurgia apenas no TCPE realizado em esteira, de 10,7 ± 4,0 para 11,5 ± 3,2 mL.bat-1 (p=0,023). No TCPE realizado em esteira, a diferença percentual do OUES apresentou significativa correlação negativa com a diferença percentual do VDFVE (r=-0,277; p=0,034), do VAE (r=-0,275; p=0,035) e da PSAP (r=-0,282; p=0,041), respectivamente. No TCPE realizado na bicicleta, a diferença percentual do OUES revelou correlação negativa apenas com a diferença percentual da PSAP (r=-0,359; p=0,010). Conclusão: A cirurgia valvar mitral, não determinou aumento do VO2 pico e do OUES apesar da melhora sintomática avaliada pela classe funcional (NYHA). Entretanto, a variável OUES apresentou correlação negativa com parâmetros ecocardiográficos de remodelação cardíaca. O TCPE é uma ferramenta útil e promissora, podendo auxiliar na conduta médica em pacientes com IM. / Introduction: Chronic organic Mitral Regurgitation (MR) has a complex physiopathology. The symptoms of heart failure and functional capacity worsening may appear too late, when a left ventricle (LV) contractile dysfunction already exists. The cardiopulmonary exercise testing (CPET) may objectively assess the functional capacity and helps in the medical conduct concerning patients with MR, but little is known about the surgery effect on its variables. Objectives: To evaluate the effects of the MR surgical correction on the variables related to the CPET performed on stationary bicycle and treadmill. Methods: A total of 72 patients with severe MR were selected and underwent a surgery for valvulopathy correction and an echocardiogram (ECHO) and CPET were performed around 30 days before the surgery and then from six to 12 months after the surgery. Results: The patients were aged an average 49.9 ± 16.9 years. There was a predominance of male patients [41 patients (56.9%)], degenerative etiology [50 patients (69.4%)] and NYHA I or II functional class [51 patients (70.8%)]. Forty-seven (47) patients (65.3%) had their mitral valves repaired and 25 patients had them replaced. After the surgery, there was a reduction in the left atrial volume (LAV) from 124.4 ± 58.9 ml to 76.4 ± 34.0 ml (p<0.001), in the LV end-diastolic volume (LVEDV) from 151.7 ± 35.7ml to 109.6 ± 42.8 ml (p<0.001), in the LV end-systolic volume (LVESV) from 47.6 ± 18.0 to 43.9 ± 27.1ml (p<0.001), in the ejection fraction (EF) from 69.1 ± 6.3 to 61.30 ± 8.2% (p<0.001) and in the pulmonary artery systolic pressure (PASP) from 46.7 ± 15.9 to 35.4 ± 12.5 mm Hg (p<0.001). A reduction in the peak consumption of oxygen (VO2) was also observed in both types of exercise testing after the surgery (stationary bicycle: from 1356 ± 506 to 1269 ± 408 mL.min-1, p=0.015; treadmill: from 1618 ± 579 to 1536 ± 447 mL.min-1, p=0.06), as well as in the variable Oxygen Uptake Efficiency Slope (OUES) (stationary bicycle: from 1530 ± 516 to 1414 ± 415, p=0.001; treadmill: from 1761 ± 585 to 1691 ± 508, p=0.050). Pulse oxymetry readings (O2) increased after the surgery only for the CPET performed on the treadmill from 10.7 ± 4.0 to 11.5 ± 3.2 mL. heartbeat -1 (p=0.023). For the CPET performed on the treadmill, the OUES percent difference showed significant negative correlation with the percent difference of LVEDV (r=-0.277; p=0.034), LAV (r=-0.275; p=0.035) and PASP (r=-0.282; p=0.041), respectively. For the CPET performed on the stationary bicycle, the percent difference of the OUES showed a negative correlation only with the percent difference of PSAP (r=-0.359; p=0.010). Conclusion: The mitral valve surgery caused no increase in the peak VO2 or OUES despite the symptomatic improvement as assessed through the functional class (NYHA). However, the variable OUES showed negative correlation with the echocardiographic parameters of cardiac remodeling. The CPET is a useful and promising tool, and may help in the medical conduct concerning patients with MR.
27

Avaliação anatômica comparativa da valva mitral e da valva aórtica de corações normais e com cardiomiopatia dilatada isquêmica e idiopática / Comparative anatomical evaluation of the mitral valve and aortic valve of normal hearts and with ischemic and idiopathic dilated cardiomyopathy

Guilherme Martins Marrelli Caldas 19 December 2006 (has links)
O objetivo deste trabalho foi estudar e comparar a valva mitral e a valva aórtica e em corações com cardiomiopatia dilatada (CMD) de etiologia isquêmica e idiopática, em relação aos corações humanos normais, buscando identificar variações que possam auxiliar em diagnósticos por imagem e para o tratamento cirúrgico das mesmas. Este estudo analisou 22 corações normais, 15 corações dilatados de etiologia isquêmica e 15 corações dilatados de etiologia idiopática, fixados em formaldeído a 10%. Foram obtidas medidas por meio de fotografias digitais dos corações e, posteriormente, utilizando-se software, foram analisados as distâncias e os perímetros da valva mitral e da valva aórtica, que foram comparadas por meio de testes estatísticos. Nos corações normais, a área da valva mitral foi de 5,44 ± 0,82 cm2 e o perímetro de 8,91 ± 0,57 cm, e nos corações com CMD de etiologia isquêmica e idiopática, a área foi de, respectivamente, 7,38 ± 1,76 cm2 e 7,03 ± 1,44 cm2, e o perímetro foi de, respectivamente, 10,41 ± 1,37 cm e 9,97 ± 1,23 cm. O perímetro de inserção da cúspide anterior da valva mitral, nos corações normais, foi de 3,68 ± 0,52 cm e nos corações com CMD de etiologia isquêmica e idiopática foi de, respectivamente, 3,99 ± 0,86 cm e 3,62 ± 0,78 cm. A menor distância perimetral entre os trígonos fibrosos (porção fibrosa), nos corações normais, foi de 2,06 ± 0,26 cm e nos corações com CMD de etiologia isquêmica e idiopática foi de, respectivamente, 2,64 ± 0,37 cm e 2,34 ± 0,37 cm. Nos corações normais, a área da valva aórtica foi de 3,46 ± 0,66 cm2 e o perímetro de 6,83 ± 0,66 cm. Nos corações com CMD de etiologia isquêmica e idiopática, a área da valva aórtica foi de, respectivamente, 5,22 ± 1,53 cm2 e 3,44 ± 1,33 cm2, e o perímetro de, respectivamente, 8,26 ± 1,24 cm e 6,82 ± 1,37 cm. Nos casos de CMD idiopática e isquêmica, a valva mitral apresentava-se aumentada, tanto na sua área e em seu perímetro, quanto na maior e na menor distância perimetral entre os trígonos fibrosos. Em relação à valva aórtica, apenas nos corações com CMD isquêmica houve aumento estatisticamente significante em sua área e em seu perímetro, enquanto que nos corações com CMD idiopática não houve diferença quando comparados aos corações normais. Há manutenção da proporcionalidade, dos corações normais para os com CMD idiopática e isquêmica, das distâncias entre os trígonos fibrosos. Há evidência de que o aumento da valva mitral e da valva aórtica, quando ocorrem na CMD, se dão de forma independente. / The objective of this work was to study and to compare mitral valve as well as aortic valve in the ischemic and idiopathic dilated cardiomyopathy (CMD) in relation to the normal hearts, searching to identify variations that can assist in diagnostic for image and for the surgical treatment of the same ones. This study it analyzed 22 normal hearts, 15 dilated hearts of ischemic etiology and 15 dilated hearts of idiopathic etiology, fixed in formaldehyde 10%. They had been gotten measured through digitalized photographs of the hearts, and, through software, the distances and perimeters of the mitral valve and of the aortic valve had been analyzed, that later they had been compared through statistical tests. In the normal hearts, the area the mitral valve was 5.44 ± 0.82 cm2 and the perimeter of 8.91 ± 0.57 cm. In the hearts with ischemic and idiopathic CMD the area of the mitral valve were, respectively, 7.38 ± 1.76 cm2 and 7.03 ± 1.44 cm2, and to the perimeter it were, respectively, 10.41 ± 1.37 cm and 9.97 ± 1.23 cm. The perimeter of insertion of anterior cusp of mitral valve in the normal hearts was 3.68 ± 0.52 cm, in the hearts with ischemic and idiopathic CMD were, respectively, 3.99 ± 0.86 cm and 3.62 ± 0.78 cm. The lesser length enter the fibrous trigones (fibrous portion) in the normal hearts was 2.06 ± 0.26 cm and in the hearts with ischemic and idiopathic CMD were, respectively, 2.64 ± 0.37 cm and 2.34 ± 0.37 cm In the normal hearts the area of aortic valve was 3.46 ± 0.66 cm2 and the perimeter of 6.83 ± 0.66 cm. In the hearts with ischemic and idiopathic CMD the area of aortic valve were, respectively, 5.22 ± 1.53 cm2 and 3.44 ± 1.33 cm2, and the perimeter of, respectively, 8.26 ± 1.24 cm and 6.82 ± 1.37 cm. In the cases of idiopathic and ischemic CMD, mitral valve is presented increased, as much in its area and its perimeter, how much in the greater and the lesser perimetral distance between the fibrous trigones. In relation to aortic valve, only in the hearts with Ischemic CMD it had significant statistic increase in its area and its perimeter, whereas in the hearts with Idiopathic CMD it did not have difference when compared with the normal hearts. It has maintenance of the proportionality, the normal hearts for the ones with idiopathic and ischemic CMD, of the distances between the fibrous trigones. It has evidence of that the increase of mitral valve and aortic valve, when they occur in the CMD, occurs of independent form.
28

Estudo biomolecular de produtos de Chlamydophila pneumoniae, Mycoplasma pneumoniae e Borrelia burgdorferi na etiopatogenia da degeneração mixomatosa da valva mitral / A biomolecular study on Chlamydophila pneumoniae, Mycoplasma pneumoniae and Borrelia burgdorferi products in myxoid mitral valve degeneration etiopathogenesis

Tiveron, Marcos Gradim 11 December 2015 (has links)
Introdução e Objetivo: A doença mixomatosa da valva mitral leva ao comprometimento de sua matriz devido à alteração em sua composição tecidual provocada pelo desequilíbrio na quantidade de ácidos mucopolissacarídeos ou glicosaminoglicanos. Sua etiologia ainda não está totalmente esclarecida, podendo ocorrer em formas familiares com transmissão autossômica dominante de penetrância variável, que pode ser dependente do tempo ou de prováveis fatores ambientais, situações em que a interação de agentes infecciosos necessita de maiores esclarecimentos. O objetivo deste estudo é a análise dos produtos dos patógenos da Chlamydophila pneumoniae, Mycoplasma pneumoniae e Borrelia burgdorferi em segmentos de cúspide retirados da valva mitral com degeneração mixomatosa, comparada ao grupo controle e a relação dos produtos bacterianos com aumento de marcadores inflamatórios (CD20, CD48, CD68) e de metaloproteinase (MMP9) na etiopatogenia da degeneração mixomatosa da valva mitral. Método: Estudo observacional, analítico, tipo caso-controle, que analisou 2 grupos contendo 20 pacientes cada e divididos em grupo 1, composto por fragmentos de tecido valvar mitral com diagnóstico de degeneração mixomatosa extraídos em procedimentos de troca ou plásticas valvares mitrais; e grupo 2, formado por segmentos de valvas mitrais sem valvopatia retirados no serviço de verificação de óbito. Foram realizadas colorações de hematoxilina e eosina e Movat para diagnóstico histológico da degeneração mixomatosa e técnica de imunohistoquímica para detecção de antígenos da Borrelia burgdorferi, Mycoplasma pneumoniae, mediadores inflamatórios (CD20, CD45, CD68) e marcadores de metaloproteinase (MMP9). A presença de antígenos da Chlamydophila pneumonia e foi pesquisada pela técnica de hibridização in situ. A análise quantitativa dos aspectos microscópicos foi realizada com o analisador de imagens Aperio. A pesquisa de elementos bacterianos foi feita através de microscopia eletrônica de transmissão. Resultados: No grupo 1, 14 (70%) pacientes são do gênero masculino e 6 (30%) do gênero feminino. A idade média é de 67,4 anos (51 a 79 anos, dp = 9,2). No grupo 2, 11 (55%) pacientes são do gênero masculino e 9 (45%) do gênero feminino. A idade média é de 67,6 anos (42 a 84 anos, dp= 12,0). Na análise da porcentagem de degeneração mixomatosa pela coloração Movat, houve diferença com significância estatística entre os grupos DM (G1), com média de 54,6 % ± 23,7 e grupo controle (G2) com média de 35,5 % ± 22,5 com valor de p = 0,013. Houve um maior número de células CD20 positivas/mm2 no grupo com DM com mediana igual a 17,8 (6,7 - 27,9) x 4,6 (3,6 - 9,8) com p = 0,007 para a área 1. Houve maior número de células CD45 positivas/mm2 no grupo com DM com mediana igual a 17,3 (3,4 - 92,5) x 2,8 (1,4 - 10,1) com p = 0,008 para a área 1. Houve maior número de células CD68 positivas/mm2 no grupo controle (G2), porém sem significância estatística com mediana igual a 38,7 (26,6 - 81,8) x 70 (42,7 - 120,4) com p = 0,098 para a área 1. Em relação à presença de antígenos de Mycoplasma pneumoniae, houve uma maior área (?m2) de antígenos detectados no grupo 1, quando comparadas com o grupo 2 com diferença estatisticamente significante para as duas áreas. Na área 1, mediana de 180.993 (24.856 - 387.477) x 7.970 (2.736 - 15.992) com p < 0,001 e na área 2, mediana igual a 105.968 (2.503 - 416.585) x 7.190 (3.314 - 17.833) com p = 0,02 A análise da presença de antígenos de Chlamydophila pneumoniae demonstrou que em ambas as áreas, houve uma maior área (?m2) de antígenos detectados no grupo de valvas com degeneração mixomatosa, quando comparadas com o grupo controle, porém sem diferença estatística com mediana para o G1 de 9.905 (4.716 - 16.912) x 5.864 (2.382 - 8.692) com p = 0,2 e para o G2, mediana de 3.199 (1.791 - 10.746) x 2.536 (683 - 6.125) com p = 0,3. Em relação à presença de antígenos de Borrelia burgdorferi, houve uma maior área (um2) de antígenos detectados no grupo 2 em relação ao grupo 1, em ambas as áreas. Na área 1, mediana de 7.596 (3.203 - 13.519) x 10.584 (7.223 - 15.974) com p = 0,14 e na área 2, mediana igual a 5.991 (3.009 - 8.475) x 8.403 (1.626 - 27.887) com p = 0,47. Em relação à presença da metaloproteinase MMP9, observamos maior área (um2) de antígeno marcado de MMP9 no grupo com degeneração mixomatosa tanto na área 1 quanto na área 2, com diferença estatística significante. Na área 1, mediana de 503.894 (202.428 - 938.072) x 269.244 (111.953 - 354.022) com p = 0,03. Na área 2, houve diferença estatística representada pela mediana de 389.844 (214.459 - 679.711) x 144.397 (29.894 - 247.453) com p < 0,001. No grupo DM houve correlação positiva entre Borrelia burgdorferi e porcentagem de DM com R = 0,52 e p = 0,018. Em relação às células inflamatórias, houve correlação positiva entre CD45 e Mycoplasma pneumoniae com R = 0,51 e p = 0,02. A presença de MMP9 se correlacionou positivamente com a presença de Mycoplasma pneumoniae com R = 0,45 e p = 0,04. Estas correlações estiveram ausentes no grupo controle. Conclusões: Houve associação de agentes infecciosos Mycoplasma pneumoniae e Borrelia burgdorferi na etiopatiopatogenia da degeneração mixomatosa da valva mitral. Na análise da relação dos produtos bacterianos com os marcadores inflamatórios e com a metaloproteinase, houve relação positiva entre o marcador inflamatório CD45 e a metaloproteinase (MMP9) apenas com a Mycoplasma pneumoniae, nas valvas com degeneração mixomatosa. O marcador inflamatório CD68 foi encontrado em maior número no grupo controle / Background: The myxomatous mitral valve disease leads to impairment due to changes in their tissue composition caused by the imbalance in the amount of acid mucopolysaccharides or glycosaminoglycans. Its etiology is not yet fully understood and may occur in familial forms of autosomal dominant trait with variable penetrance that can be time-dependent or probable environmental factors, where the interaction of infectious agents requires further elucidation. The purpose of this study is the analysis of the pathogens products of Chlamydophila pneumoniae, Mycoplasma pneumoniae and Borrelia burgdorferi in removed cusp segments of the mitral valve with myxoid degeneration, compared to the control group and the ratio of bacterial products with increased inflammatory markers (CD20, CD48, CD68) and metalloproteinase (MMP9) in the pathogenesis of myxomatous degeneration of the mitral valve. Method: Observational, analytical, case-control study which analyzed 2 groups of 20 patients each and divided in group 1, consisting of fragments of mitral valve tissue with diagnosis of myxomatous degeneration extracted in replacement procedures or mitral valve repair; group 2, formed by segments of mitral valves without valvolpaty clinial disease removed in the coroner service. Hematoxylin and eosin and Movat stains were done for histological diagnosis of myxoid degeneration and immunohistochemical technique for the detection of Borrelia burgdorferi, Mycoplasma pneumonia antigens, inflammatory mediators (CD20, CD45, CD68) and markers of metalloproteinase (MMP9). The presence of Chlamydophila pneumonia antigens was verified through an in situ hybridization technique. The quantitative analysis of the microscopic aspects was performed with the Aperio image analyzer. The research of bacterial elements was performed by a transmission electron microscopy. Results: In group 1, 14 (70%) patients were male and 6 (30%) were female. The mean age was (51 to 79 years, sd = 9.2). In group 2, 11 (55%) patients were male gender and 9 (45%) were female. The mean age was 67,6 years (42 to 84 years, sd= 12). In the analysis percentage of myxomatous tissue by Movat staining, there was a significant difference between the DM (G1) groups, with a media of 54.6 % ± 23,7 and control group (G2) with a media of 35.5 % ± 22.5 with p = 0.013. There was an increased number of CD20 cells/mm2 in myxomatous degeneration group (G1) with a median of 17.8 (6.7 - 27.9) x 4.6 (3.6 - 9.8) with p = 0.007 for the area 1. There was a higher number of CD45 cells/mm2 in myxomatous degeneration group (G1) with a median of 17.3 (3.4 - 92.5) x 2.8 (1.4 - 10.1) with p = 0.008 for the area 1. There was a higher number of CD68 cells/mm2 in control group (G2) without a statistically significant difference, with a median of 38.7 (26.6 - 81.8) x 70 (42.7 - 120.4) with p = 0,098 for the area 1. In quantifying Mycoplasma pneumoniae we observed a higher area (um2) antigen marked by, there was a higher amount of antigen detected in myxomatous degeneration group. In area 1, a median of 180,993 (24,856 - 387,477) x 7,970 (2,736 - 15,992) with p < 0.001 and in area 2, a median of 105,968 (2,503 - 416,585) x 7,190 (3,314 - 17,833) with p = 0.02. The analysis of the presence of Chlamydophila pneumoniae antigens showed that in both area, there was a larger area (?m2) antigens detected in the group of valves with MD when compared with the control group, but without significant differences with median for the G1 of 9,905 (4,716 - 16,912) x 5,864 (2,382 - 8,692), with p = 0.2 and the G2, median 3,199 (1,791 - 10,746) x 2,536 (683 - 6,125) with p = 0.3. Regarding the presence of Borrelia burgdorferi antigens, there was a greater area (?m2) antigens detected in group 2 than in group 1, in both areas. In one area, median 7,596 (3,203 - 13,519) x 10,584 (7,223 - 15,974), with p = 0.14 and in area 2, a median of 5,991 (3,009 - 8,475) x 8,403 (1,626 - 27,887) with p = 0.47. Regarding the presence of metalloproteinase MMP9, we observed a higher area (um2) antigen marked by MMP9 in the group with MD both in area 1and area 2, with statistically significant difference. In area 1, median of 503,894 (202,428 - 938,072) x 269,244 (111,953 - 354,022), p = 0.03. In area 2, median 389,844 (214,459 - 679,711) x 144,397 (29,894 - 247,453) with p < 0.001. In the DM group there was a positive correlation between Borrelia burgdorferi and the percentage of MD with R = 0.52 and p = 0.018. Regarding inflammatory cells, there was a positive correlation between CD45 and Mycoplasma pneumoniae with R = 0.51 and p = 0.02. The presence of MMP9 was positively correlated with the presence of Mycoplasma pneumoniae with R = 0.45 and p = 0.04. These correlations were absent in the control group. Conclusions: There was an association of infectious agents Mycoplasma pneumoniae and Borrelia burgdorferi in etiopathogeny of myxoid degeneration of the mitral valve. In the analysis of the relationship of bacterial products with the inflammatory markers and the metalloproteinase, there was a positive relationship between the inflammatory marker CD45 and metalloproteinase (MMP9) only with Mycoplasma pneumoniae. The inflammatory marker CD68 was found in greater numbers in the control group
29

Estudo biomolecular de produtos de Chlamydophila pneumoniae, Mycoplasma pneumoniae e Borrelia burgdorferi na etiopatogenia da degeneração mixomatosa da valva mitral / A biomolecular study on Chlamydophila pneumoniae, Mycoplasma pneumoniae and Borrelia burgdorferi products in myxoid mitral valve degeneration etiopathogenesis

Marcos Gradim Tiveron 11 December 2015 (has links)
Introdução e Objetivo: A doença mixomatosa da valva mitral leva ao comprometimento de sua matriz devido à alteração em sua composição tecidual provocada pelo desequilíbrio na quantidade de ácidos mucopolissacarídeos ou glicosaminoglicanos. Sua etiologia ainda não está totalmente esclarecida, podendo ocorrer em formas familiares com transmissão autossômica dominante de penetrância variável, que pode ser dependente do tempo ou de prováveis fatores ambientais, situações em que a interação de agentes infecciosos necessita de maiores esclarecimentos. O objetivo deste estudo é a análise dos produtos dos patógenos da Chlamydophila pneumoniae, Mycoplasma pneumoniae e Borrelia burgdorferi em segmentos de cúspide retirados da valva mitral com degeneração mixomatosa, comparada ao grupo controle e a relação dos produtos bacterianos com aumento de marcadores inflamatórios (CD20, CD48, CD68) e de metaloproteinase (MMP9) na etiopatogenia da degeneração mixomatosa da valva mitral. Método: Estudo observacional, analítico, tipo caso-controle, que analisou 2 grupos contendo 20 pacientes cada e divididos em grupo 1, composto por fragmentos de tecido valvar mitral com diagnóstico de degeneração mixomatosa extraídos em procedimentos de troca ou plásticas valvares mitrais; e grupo 2, formado por segmentos de valvas mitrais sem valvopatia retirados no serviço de verificação de óbito. Foram realizadas colorações de hematoxilina e eosina e Movat para diagnóstico histológico da degeneração mixomatosa e técnica de imunohistoquímica para detecção de antígenos da Borrelia burgdorferi, Mycoplasma pneumoniae, mediadores inflamatórios (CD20, CD45, CD68) e marcadores de metaloproteinase (MMP9). A presença de antígenos da Chlamydophila pneumonia e foi pesquisada pela técnica de hibridização in situ. A análise quantitativa dos aspectos microscópicos foi realizada com o analisador de imagens Aperio. A pesquisa de elementos bacterianos foi feita através de microscopia eletrônica de transmissão. Resultados: No grupo 1, 14 (70%) pacientes são do gênero masculino e 6 (30%) do gênero feminino. A idade média é de 67,4 anos (51 a 79 anos, dp = 9,2). No grupo 2, 11 (55%) pacientes são do gênero masculino e 9 (45%) do gênero feminino. A idade média é de 67,6 anos (42 a 84 anos, dp= 12,0). Na análise da porcentagem de degeneração mixomatosa pela coloração Movat, houve diferença com significância estatística entre os grupos DM (G1), com média de 54,6 % ± 23,7 e grupo controle (G2) com média de 35,5 % ± 22,5 com valor de p = 0,013. Houve um maior número de células CD20 positivas/mm2 no grupo com DM com mediana igual a 17,8 (6,7 - 27,9) x 4,6 (3,6 - 9,8) com p = 0,007 para a área 1. Houve maior número de células CD45 positivas/mm2 no grupo com DM com mediana igual a 17,3 (3,4 - 92,5) x 2,8 (1,4 - 10,1) com p = 0,008 para a área 1. Houve maior número de células CD68 positivas/mm2 no grupo controle (G2), porém sem significância estatística com mediana igual a 38,7 (26,6 - 81,8) x 70 (42,7 - 120,4) com p = 0,098 para a área 1. Em relação à presença de antígenos de Mycoplasma pneumoniae, houve uma maior área (?m2) de antígenos detectados no grupo 1, quando comparadas com o grupo 2 com diferença estatisticamente significante para as duas áreas. Na área 1, mediana de 180.993 (24.856 - 387.477) x 7.970 (2.736 - 15.992) com p < 0,001 e na área 2, mediana igual a 105.968 (2.503 - 416.585) x 7.190 (3.314 - 17.833) com p = 0,02 A análise da presença de antígenos de Chlamydophila pneumoniae demonstrou que em ambas as áreas, houve uma maior área (?m2) de antígenos detectados no grupo de valvas com degeneração mixomatosa, quando comparadas com o grupo controle, porém sem diferença estatística com mediana para o G1 de 9.905 (4.716 - 16.912) x 5.864 (2.382 - 8.692) com p = 0,2 e para o G2, mediana de 3.199 (1.791 - 10.746) x 2.536 (683 - 6.125) com p = 0,3. Em relação à presença de antígenos de Borrelia burgdorferi, houve uma maior área (um2) de antígenos detectados no grupo 2 em relação ao grupo 1, em ambas as áreas. Na área 1, mediana de 7.596 (3.203 - 13.519) x 10.584 (7.223 - 15.974) com p = 0,14 e na área 2, mediana igual a 5.991 (3.009 - 8.475) x 8.403 (1.626 - 27.887) com p = 0,47. Em relação à presença da metaloproteinase MMP9, observamos maior área (um2) de antígeno marcado de MMP9 no grupo com degeneração mixomatosa tanto na área 1 quanto na área 2, com diferença estatística significante. Na área 1, mediana de 503.894 (202.428 - 938.072) x 269.244 (111.953 - 354.022) com p = 0,03. Na área 2, houve diferença estatística representada pela mediana de 389.844 (214.459 - 679.711) x 144.397 (29.894 - 247.453) com p < 0,001. No grupo DM houve correlação positiva entre Borrelia burgdorferi e porcentagem de DM com R = 0,52 e p = 0,018. Em relação às células inflamatórias, houve correlação positiva entre CD45 e Mycoplasma pneumoniae com R = 0,51 e p = 0,02. A presença de MMP9 se correlacionou positivamente com a presença de Mycoplasma pneumoniae com R = 0,45 e p = 0,04. Estas correlações estiveram ausentes no grupo controle. Conclusões: Houve associação de agentes infecciosos Mycoplasma pneumoniae e Borrelia burgdorferi na etiopatiopatogenia da degeneração mixomatosa da valva mitral. Na análise da relação dos produtos bacterianos com os marcadores inflamatórios e com a metaloproteinase, houve relação positiva entre o marcador inflamatório CD45 e a metaloproteinase (MMP9) apenas com a Mycoplasma pneumoniae, nas valvas com degeneração mixomatosa. O marcador inflamatório CD68 foi encontrado em maior número no grupo controle / Background: The myxomatous mitral valve disease leads to impairment due to changes in their tissue composition caused by the imbalance in the amount of acid mucopolysaccharides or glycosaminoglycans. Its etiology is not yet fully understood and may occur in familial forms of autosomal dominant trait with variable penetrance that can be time-dependent or probable environmental factors, where the interaction of infectious agents requires further elucidation. The purpose of this study is the analysis of the pathogens products of Chlamydophila pneumoniae, Mycoplasma pneumoniae and Borrelia burgdorferi in removed cusp segments of the mitral valve with myxoid degeneration, compared to the control group and the ratio of bacterial products with increased inflammatory markers (CD20, CD48, CD68) and metalloproteinase (MMP9) in the pathogenesis of myxomatous degeneration of the mitral valve. Method: Observational, analytical, case-control study which analyzed 2 groups of 20 patients each and divided in group 1, consisting of fragments of mitral valve tissue with diagnosis of myxomatous degeneration extracted in replacement procedures or mitral valve repair; group 2, formed by segments of mitral valves without valvolpaty clinial disease removed in the coroner service. Hematoxylin and eosin and Movat stains were done for histological diagnosis of myxoid degeneration and immunohistochemical technique for the detection of Borrelia burgdorferi, Mycoplasma pneumonia antigens, inflammatory mediators (CD20, CD45, CD68) and markers of metalloproteinase (MMP9). The presence of Chlamydophila pneumonia antigens was verified through an in situ hybridization technique. The quantitative analysis of the microscopic aspects was performed with the Aperio image analyzer. The research of bacterial elements was performed by a transmission electron microscopy. Results: In group 1, 14 (70%) patients were male and 6 (30%) were female. The mean age was (51 to 79 years, sd = 9.2). In group 2, 11 (55%) patients were male gender and 9 (45%) were female. The mean age was 67,6 years (42 to 84 years, sd= 12). In the analysis percentage of myxomatous tissue by Movat staining, there was a significant difference between the DM (G1) groups, with a media of 54.6 % ± 23,7 and control group (G2) with a media of 35.5 % ± 22.5 with p = 0.013. There was an increased number of CD20 cells/mm2 in myxomatous degeneration group (G1) with a median of 17.8 (6.7 - 27.9) x 4.6 (3.6 - 9.8) with p = 0.007 for the area 1. There was a higher number of CD45 cells/mm2 in myxomatous degeneration group (G1) with a median of 17.3 (3.4 - 92.5) x 2.8 (1.4 - 10.1) with p = 0.008 for the area 1. There was a higher number of CD68 cells/mm2 in control group (G2) without a statistically significant difference, with a median of 38.7 (26.6 - 81.8) x 70 (42.7 - 120.4) with p = 0,098 for the area 1. In quantifying Mycoplasma pneumoniae we observed a higher area (um2) antigen marked by, there was a higher amount of antigen detected in myxomatous degeneration group. In area 1, a median of 180,993 (24,856 - 387,477) x 7,970 (2,736 - 15,992) with p < 0.001 and in area 2, a median of 105,968 (2,503 - 416,585) x 7,190 (3,314 - 17,833) with p = 0.02. The analysis of the presence of Chlamydophila pneumoniae antigens showed that in both area, there was a larger area (?m2) antigens detected in the group of valves with MD when compared with the control group, but without significant differences with median for the G1 of 9,905 (4,716 - 16,912) x 5,864 (2,382 - 8,692), with p = 0.2 and the G2, median 3,199 (1,791 - 10,746) x 2,536 (683 - 6,125) with p = 0.3. Regarding the presence of Borrelia burgdorferi antigens, there was a greater area (?m2) antigens detected in group 2 than in group 1, in both areas. In one area, median 7,596 (3,203 - 13,519) x 10,584 (7,223 - 15,974), with p = 0.14 and in area 2, a median of 5,991 (3,009 - 8,475) x 8,403 (1,626 - 27,887) with p = 0.47. Regarding the presence of metalloproteinase MMP9, we observed a higher area (um2) antigen marked by MMP9 in the group with MD both in area 1and area 2, with statistically significant difference. In area 1, median of 503,894 (202,428 - 938,072) x 269,244 (111,953 - 354,022), p = 0.03. In area 2, median 389,844 (214,459 - 679,711) x 144,397 (29,894 - 247,453) with p < 0.001. In the DM group there was a positive correlation between Borrelia burgdorferi and the percentage of MD with R = 0.52 and p = 0.018. Regarding inflammatory cells, there was a positive correlation between CD45 and Mycoplasma pneumoniae with R = 0.51 and p = 0.02. The presence of MMP9 was positively correlated with the presence of Mycoplasma pneumoniae with R = 0.45 and p = 0.04. These correlations were absent in the control group. Conclusions: There was an association of infectious agents Mycoplasma pneumoniae and Borrelia burgdorferi in etiopathogeny of myxoid degeneration of the mitral valve. In the analysis of the relationship of bacterial products with the inflammatory markers and the metalloproteinase, there was a positive relationship between the inflammatory marker CD45 and metalloproteinase (MMP9) only with Mycoplasma pneumoniae. The inflammatory marker CD68 was found in greater numbers in the control group
30

Fibrose miocárdica associada à insuficiência mitral crônica: estudo pela ressonância magnética / Myocardic fibrosis associated with chronic mitral insuficiency. A magnetic resonance study

Mansano, Joyce do Amaral Genta 10 August 2009 (has links)
Introdução: A história natural da insuficiência mitral associa-se a décadas de remodelação ventricular esquerda com fibrose intersticial. A fronteira entre o processo adaptativo e a miocardiopatia dilatada demanda avaliação clínico-histológica. Atualmente, sabe-se que o melhor método empregado para quantificar as alterações decorrentes do remodelamento que acomete o ventrículo esquerdo é a biópsia miocárdica, que analisa a doença, somente após a cirurgia ou no post mortem. O presente estudo visa avaliar a fibrose miocárdica associada à insuficiência mitral crônica, através de estudo pela Ressonância Magnética, de maneira não invasiva, precoce e rápida. Objetivos: Avaliar a capacidade e a aplicabilidade da ressonância magnética cardíaca de detectar a fibrose miocárdica na insuficiência mitral crônica importante, tendo como referência a biópsia miocárdica. Métodos: Foram selecionados 52 pacientes portadores de IM crônica pura ou associada a estenose mitral leve, com PVM e DR, e com indicação cirúrgica. Todos os pacientes foram reavaliados pelo EcoDopplercardiograma e realizaram ressonância magnética cardíaca para avaliação da função ventricular, volumes e índice de massa ventricular esquerda, através da cine-ressonância e pela técnica do realce tardio miocárdico, com injeção de 0,2 mmol/kg de contraste gadolínio para a detecção de FM, sendo submetidos a cirurgia de plástica ou troca de válvula mitral com bióspsias miocárdicas, retiradas de locais padrão, na parede lateral do ventrículo esquerdo. Todas foram coradas pela técnica do hematoxilinaeosina, e as positivas para FM, confirmadas pelo corante picrossirius, que cora colágeno, e quantificadas pelo aparelho do quantimet. Resultados: Os pacientes foram divididos em quatro grupos, conforme a RM e a biópsia. A RM diagnosticou FM em 18 pacientes, concordantes com a BM (RMC/BM +). A RM foi negativa para FM em 33 pacientes, sendo 28 concordantes com a BM (RMC/BM -). Observou-se discordância de RM com a BM, em 7 casos falsos negativos (RMC-/BM +). A sensibilidade da RMC à fibrose foi de 72%, especificidade de 100%, e acurácia de 86,3%. Nos grupos distintos estudados, a sensibilidade, especificidade e acurácia foram de 64,7%, 100% e 82,4%, respectivamente, na PVM, e de 97,5%, 100% e 92,9%, respectivamente, na DR. O índice Kappa foi de 0,724 (p<0,001) para o grupo total; 0,665 (p<0,001) para PVM e 0,857(p<0,001) na DR. VDF, VSF e IMVE tiveram correlação positiva e significativa com a porcentagem de fibrose, sendo que, quanto maiores esses valores, maior a porcentagem de fibrose. Conclusão: RMC teve boa concordância com a BM, em relação aos achados de FM / Introduction: The natural history of mitral insufficiency (MI) is associated to decades of left ventricular remodelation with intersticial fibrosis. The frontier between adaptative process and dilatade miocardiopaty needs clinic and histologic evaluation. Now a days , we know that the best method to quantify the alterations of remodelation in left ventricule is myocardial biopsies which analyses the illness only after surgery or post morten. This actual study aims to evaluate myocardial fibrosis associated with cronic MI, through the study with magnetic resonance (MR), in a not invasive, early and quickly way. Objectives: Evaluate capacity and applicability of the magnetic resonance in detection of myocardial fibrosis in chronic important mitral insufficiency in reference with myocardial biopsis. Methods: It was selected 52 patients with pure chronic MI or associated with mild mitral stenosis, with cirurgical indication. All of the patients were reevaluated by EcoDopplercardiogram and it was done cardiac MR to evaluate ventricular function, volumes and left ventricular mass rate through MR cine and myocardial late realce techinique with 0,2 mmol/Kg with gadoline contrast and myocardial fibrosis (MF) detection and being undergone plastic or mitral valvular changes surgery with myocardial biopsis (MB) were taken from the left ventricular lateral wall. All of them were colored with hematoxilin eosine and the positives were confirmated with picrossirius and quantified with quantimet device. Results: Patients were divided in four groups according to MR and biopsies. MR diagnosticated MF in 18 patients agreed with MB (MR / MB +). MR was negative for MF in 33 patients where 28 agreed with MB (MR / MB -). We observated discordance with MR and MB in 7 cases false negatives (MR- /MB+). The sensibility of MR to fibrosis was 72%, specificity was 100% and acurace was 86,3%. In the distinct groups studied, we see sensibility, specifity and acure were 64,7%, 100 % and 82,4% respectivity in PVM and 97,5%, 100% and 92,9% respectivity in reumathic disease. The Kappa indice is 0,714 (p<0,001) for the total group; 0,665 (p<0,001) for PMV and 0,857 (p<0,001) in RD. There is a positive correlation and significative between fibroses percentage with VDF, VSF, IMVE of the MR. So the higher the values, higher the fibrosis percentage. Conclusion: MR had a good concordance with MB in relation to found the MF in IMC

Page generated in 0.0637 seconds