Spelling suggestions: "subject:"ventilação."" "subject:"destilação.""
451 |
Efeitos da filtragem de leucócitos sobre a resposta inflamatória e a função pulmonar de pacientes submetidos à revascularização miocárdica com circulação extracorpórea / Effects of leukocyte filtering on the inflammatory response and pulmonary function in patients undergoing coronary artery bypass grafting with cardiopulmonary bypassAmorim, Celio Gomes de 09 September 2014 (has links)
INTRODUÇÃO E OBJETIVOS: A Circulação extracorpórea (CEC) é associada a ativação leucocitária, resposta inflamatória e disfunção pulmonar. Objetivou-se avaliar os efeitos da filtragem leucocitária sobre a resposta inflamatória e a função pulmonar em indivíduos submetidos à revascularização do miocárdio (RM) com CEC. MÉTODO: Após aprovação pelo Comitê de Ética Institucional e obtenção do consentimento informado dos indivíduos, foi realizado estudo prospectivo randomizado, para comparar indivíduos adultos submetidos à RM com CEC, utilizando-se filtragem leucocitária (n=09) ou filtro standard (n=11) durante a CEC. Tomografia computadorizada (CT) de tórax, espirometria, análise da oxigenação e hemograma foram realizados antes da cirurgia. A anestesia foi induzida por via venosa com etomidato (0,3 mg.kg-1), sufentanil (0,3 ug.kg-1), pancurônio (0,08 mg.kg-1) e mantida com isoflurano (0,5 - 1,0 CAM) e sufentanil (0,5 ug.kg-1.h-1). A ventilação mecânica utilizou volume corrente de 8 mL.kg-1, com FiO2 de 0,6 e PEEP de 5 cm H2O, exceto durante a CEC. No grupo Filtragem, durante a CEC, foi inserido um filtro de leucócitos na linha arterial do circuito (LG-6, Pall Biomedical Products) e, no grupo Controle, foi utilizado o filtro Standard. Contagem leucocitária foi realizada após a indução, aos 5, 25 e 50 min de CEC, ao final da cirurgia, com 12 e 24 h PO. Dados hemodinâmicos, PaO2/FiO2, fração de Shunt, interleucinas, elastase e mieloperoxidase foram colhidos antes e após a CEC, no final da cirurgia, com 6,12 e 24 h PO. Trinta minutos depois da indução, e trinta após a CEC, três amostras sequenciais de ar exalado foram colhidas para análise de óxido nítrico (NO), por quimiluminescência. Espirometria e CT de tórax foram realizadas no primeiro dia pós-operatório. Os dados foram analisados por meio de ANOVA de duplo fator para medidas repetidas. RESULTADOS: O tempo de CEC foi similar entre os grupos controle e filtragem (86,78 ± 19,58 versus 104,64 ± 27,76 min, p=0,161). O grupo Filtragem mostrou menor contagem leucocitária que o grupo Controle até 50 min de CEC (3384 ± 2025 versus 6478 ± 3582 U.mm-3 U.mm-3, p=0,036), menor fração de shunt até 6 h PO (10 ± 2% versus 16 ± 5%, p=0,040) e menores níveis de IL-10 até o final da cirurgia (1571 ± 1137 pg.mL-1 versus 3108 ± 1694 pg.mL-1, p=0,031). Não houve diferença estatisticamente significativa entre os grupos em relação ao restante dos parâmetros avaliados (p > 0,05). CONCLUSÕES: A filtragem leucocitária durante a CEC, quando comparada à utilização de filtro convencional, promove diminuição da contagem de neutrófilos até 50 minutos de CEC, menor liberação de IL-10 até o final da cirurgia e menor alteração da fração de shunt intrapulmonar até 6 h PO, protegendo os pulmões apenas temporariamente contra a injúria aguda relacionada / BACKGROUND AND OBJECTIVE: The Cardiopulmonary bypass (CPB) is related to leukocyte activation, inflammatory response and lung dysfunction. The aim of this study was to evaluate the effects of CPB-leukocyte filtration on the inflammatory response and lung function after coronary artery bypass grafting (CABG). METHODS: After approval by the institutional ethics committee and informed consent, a prospective randomized study was performed to compare CABG-patients undergoing CPB-leukocyte filtration (n=9) or standard CPB (n=11). Espirometry, chest computed tomography (CT), oxygenation analysis and leukocyte count were performed before surgery. Anesthesia induction was performed intravenously with etomidate (0,3 mg.kg-1), sufentanil (0,3 ug.kg-1), pancuronium bromide (0,08 mg.kg-1) e sustained with isoflurano (0,5 - 1,0 CAM) and sufentanil (0,5 ug.kg-1.h-1). The tidal volume used during mechanical ventilation was 8 mL.kg-1, the FiO2 0.6 and PEEP 5 cm H2O, except during CPB. In Filtered group, during CPB, was inserted a leukocyte filter in the arterial line of CPB circuit (LG-6, Pall Biomedical Products) and, in Control group, the Standard arterial line filter was utilized. Hemodynamic data, PaO2/FiO2, shunt fraction, interleukins, elastase and myeloperoxidase were evaluated before and after CPB, at the end of surgery, and 6, 12 and 24 h PO. Thirty minutes after induction, and Thirty after CPB, three sequential exhaled air samples were collected to perform analysis of nitric oxide (NO), by chemiluminescence technique. Espirometry and chest CT were performed on first PO. Data were analyzed using two-factor ANOVA for repeated measurements. RESULTS: Length of CPB was similar in the filtered and control groups (86.78 ± 19.58 versus 104.64 ± 27.76 min, p = 0.161). The filtered group showed lower neutrophil counts than the control group up to 50 minutes of CPB (3384 ± 2025 versus 6478 ± 3582 U/mm-3, p = 0.036), lower shunt fraction up to 6 hours after surgery (10 ± 2% versus 16 ± 5%, p = 0.040), and lower levels of IL-10 at the end of surgery (1571 ± 1137 pg.ml-1 versus 3108 ± 1694 pg.ml-1, p = 0.031). There were no significant differences between the groups with respect to rest of the parameters evaluated (p >u0,05). CONCLUSIONS: The leukocyte filtration during CPB, when compared to the use of conventional filter, promotes lower neutrophil counts up to 50 minutes of CPB, lower levels of IL-10 at the end of surgery and lower shunt fraction up to 6 hours after surgery, protecting the lungs only temporarily against the acute injury related Trial registration: Clinicaltrials.gov identifier: NCT01469676
|
452 |
Avaliação da conformidade de práticas de controle e prevenção da pneumonia associada à ventilação mecânica em um hospital público de ensino / Evaluation of compliance to the practices of control and prevention of ventilator-associated pneumonia in a public teaching hospitalMenezes, Isa Rodrigues da Silveira Cabral de 11 December 2009 (has links)
Há praticamente consenso de que o processo de trabalho de controle e prevenção de infecção associada a serviços de saúde (IASS) atualmente hegemônico, pautado em indicadores de resultados, ou seja, eventos de IASS, são limitados para reconhecer as condições reais em que as práticas assistenciais são realizadas. Para tanto, avaliações processuais vêm sendo demandadas, para conhecer o grau de conformidade dessas ocorrências com as recomendações dadas por evidências científicas atualmente disponíveis. Este estudo teve a finalidade de avaliar a conformidade de práticas de controle e prevenção de pneumonia associada à ventilação mecânica (PAVM), por meio de indicadores clínicos processuais especificamente elaborados. Tais práticas corresponderam a: a) Avaliação da adesão às medidas específicas de prevenção e controle de PAVM: manutenção da cabeceira elevada a 30-45o; atendimento diário de fisioterapia respiratória; utilização de soluções estéreis para nebulizadores e inaladores; material de terapia respiratória em uso respeitando a rotina de troca estabelecida; b) Avaliação da adesão à realização de higiene bucal; c) Avaliação da adesão á higiene das mãos em procedimentos de aspiração orotraqueal, troca de cadarço da cânula orotraqueal e higiene bucal. Tratou-se de uma pesquisa aplicada envolvendo achados sobre o desempenho de práticas e procedimentos, buscando acessar sua qualidade, com delineamentos prospectivo, transversal e analítico. O cenário constituiu da UTI-Adulto de um Hospital Público de Ensino. A casuística correspondeu às oportunidades de avaliação das práticas selecionadas, realizadas por enfermeiros, auxiliares e técnicos de enfermagem e fisioterapeutas, nos três turnos de trabalho, em pacientes com intubação orotraqueal. A amostra baseou-se na conformidade esperada de 80%, acarretando 1748 avaliações distribuídas entre as práticas selecionadas, realizadas por meio de observação direta e registros em prontuários. Instrumentos e avaliadores foram submetidos à testes de aferição de concordância. O índice de conformidade geral obtido na adesão às medidas específicas de controle e prevenção de PAVM foi 68,0%, sendo que o turno da tarde apresentou o maior índice (72,4%) e o da manhã, o menor (63,2%). O índice de conformidade geral da prática de higiene bucal foi 60,1%, sendo que o turno da manhã apresentou o melhor índice (72,4%) e noturno, o menor (47,4%). Dentre as modalidades prescritas, a que apresentou maior conformidade foi a aplicação apenas de CHX 0,12%, em todos os turnos, mas somente o da manhã atingiu a conformidade mínima esperada (90%-manhã; 73,7%-noite; 72,9%-tarde). A modalidade menos acatada foi a escovação de dentes e aplicação de CHX 0,12%, em todos os turnos de trabalho (3,6%-noite; 28,6%-tarde; 33,3%-manhã). A conformidade geral da prática de higiene das mãos na realização dos procedimentos selecionados foi apenas 10,7%, sendo que a aspiração orotraqueal obteve maior conformidade (18,9%), seguindo-se troca de cadarço (7,9%) e higiene bucal (5,3%). O turno da manhã obteve maior adesão (16,7%) e o noturno a menor (3,1%). Nesta prática, o maior índice de conformidade foi obtido entre os fisioterapeutas (25,8%), seguindose os enfermeiros (15,6%) e, por último, auxiliares e técnicos (4,4%). Concluiu-se que embora as práticas avaliadas não tenham alcançado a conformidade geral esperada de 80% em nenhuma das avaliações, os resultados obtidos permitem inferir que as realidades observadas justificam a revisão de normas e rotinas instituídas, bem como a elaboração de estratégias que assegurem a adesão duradoura das práticas de controle e prevenção de PAVM, associado à análise contínua de infra-estrutura e condições de trabalho. Tornou-se evidente, também, a relevância de avaliações processuais constituírem atividades rotineiras de programas de controle e prevenção de IASS / There is a present consensus that the process of control and prevention of infection associated to health services (IAHS) based on result indicators is limited to recognize the real conditions in which assistance practices are performed. So, processual evaluations have been required to know the conformity level of these events in relation to recommendations given by scientific evidence now available. The aim of this study was to analyze the conformity of adhesion to the practices of control and prevention of ventilator-associated pneumonia (VAP) by means of specifically elaborated processual clinical indicators. These practices corresponded to: a) Evaluation of adherence to specific measures of prevention and control of VAP: maintaining the bed in a 30-45 degrees head-up position; daily respiratory physiotherapy; use of sterile solutions for nebulizers and inhalers; material of respiratory therapy in use respecting established routine of change; b) Evaluation of adherence to oral hygiene; c) Evaluation of adherence to hand-washing procedures when performing orotracheal aspiration, change of tape of the orotracheal cannula and oral hygiene. This was an applied research involving findings on performance of practices and procedures aiming to access its quality, through a prospective transversal and analytical design. It took place in an Adult-ICU of a Public Teaching Hospital. The casuistic corresponded to opportunities of evaluation of the selected practices performed by nurses, nursing assistant, nursing technicians and physiotherapists in the three work shifts in patients with orotracheal intubation. The sample was based on the expected conformity of 80%, with 1,748 evaluations distributed among the selected practices performed by means of direct observation and registers in patient records. Instruments and evaluators were submitted to tests for measuring compliance. The general conformity adhesion index obtained in the specific measures of control and prevention of VAP was 68.0%, of which the afternoon shift presented the greatest index (72.4%) and the morning shift with the lowest index (63.2%). The index of general conformity to the practice of oral hygiene was 60.1%, of which the morning shift presented the best index (72.4%) and the night shift with the worst (47.4%). Among the mentioned modalities the largest conformity was the CHX 0.12% application in all shifts, but only the morning shift reached the minimum expected conformity (90% in the morning; 73.7% at night and 72.9% in the afternoon). The less accepted modality was teeth cleaning and CHX 0.12% application in all shift works (3.6% at night; 28.6% in the afternoon; 33.3% in the morning). General conformity of hand hygiene practice in the performance of selected procedures was only 10.7%, the largest conformity represented by orotracheal aspiration (18.9%), followed by tape change (7.9%) and oral hygiene (5.3%). The morning shift obtained the best adherence (16.7%) and night shift the worst (3.1%). In this practice the best index of conformity was observed among the physiotherapists (25.8%), followed by nurses (15.6%) and the nursing assistants and technicians (4.4%). We concluded that the lack of the expected general adherence of 80% in all the evaluations justify a review of the rules and routines established, as well as the elaboration of strategies capable to assure a permanent adherence to the control and prevention practices of VAP, associated to a continuum analysis of infrastructure and work conditions. It was also evident the relevance of processual evaluations as routine activities of control and prevention programs of VAP
|
453 |
Estudo de eficiência da ventilação em sistema de climatização com distribuição de ar pelo piso. / Ventilation effectiveness study of an underfloor air distribution system.Marè, Renata Maria 21 May 2010 (has links)
A aplicação de sistemas de climatização com distribuição de ar pelo piso tem aumentado em países desenvolvidos, o que também tem ocorrido no Brasil. Em paralelo, tem crescido o interesse pela qualidade do ar interior e os seus efeitos no bem estar, saúde e produtividade dos ocupantes de uma edificação. Diversos estudos têm apontado para as vantagens deste sistema em relação à remoção de contaminantes do ambiente interior. Este sistema tem figurado nos programas de certificação ambiental de edificações como uma alternativa vantajosa para a melhoria da qualidade do ar interior e o conforto térmico com preservação da eficiência energética, recebendo pontuação adicional. Com o crescente interesse por este tipo de sistema, estudos que aprimorem o seu projeto visando à melhor eficiência global mostram-se essenciais. Este estudo tem como principal objetivo verificar experimentalmente a contribuição de um sistema de climatização com distribuição de ar pelo piso para a qualidade do ar interior de um ambiente, sendo este uma sala de aula para 48 alunos situada no Departamento de Engenharia de Construção Civil da Escola Politécnica da Universidade de São Paulo, em condições reais de uso. Para isso, foram medidas as concentrações de partículas em suspensão na zona de respiração para pessoas sentadas (a 1,10 m do piso), e no retorno do ar (a 2,60 m do piso) simultaneamente, sob seis diferentes valores de temperatura do ar na zona ocupada (a 0,60 m do piso), previamente escolhidos. Estas concentrações permitiram o cálculo e a análise do índice de efetividade na remoção de contaminantes IERC no ambiente, para partículas e CO2 (segunda etapa das medições). Simultaneamente, foram realizadas medições de variáveis de conforto térmico no ambiente, temperatura do ar e velocidade do ar, em seis diferentes alturas e quatorze pontos do ambiente. As baixas concentrações de partículas em suspensão (inferiores a 0,035 mg/m³) mostraram que este sistema não dispersa contaminantes no ar interior. Os IERC próximos ou superiores à unidade em todas as condições de operação do sistema, tanto para partículas em suspensão como para CO2, comprovaram a sua eficiência na remoção de contaminantes do ambiente interior. / The use of underfloor air distribution (UFAD) systems is growing in developed countries, and this is also observed in Brazil. Besides, the interest in indoor air quality and its effects on the well being, health and productivity of the occupants in a building is an important issue nowadays. Many studies have related the advantages of UFAD systems in removing indoor air contaminants from the ambient as compared to overhead systems. In the building certification systems, they figure as good alternatives to promote better indoor air quality and thermal comfort, preserving energy efficiency, which corresponds to additional points. With the expanding interest in this technology, studies that enhance its project, keeping as a goal its global efficiency, are very welcome. The aim is to experimentally verify the contribution of an UFAD system to the indoor air quality of a classroom used by 48 students at the Civil Construction Department of the Engineering School of the University of São Paulo Brazil. The study has been conducted in a non-steady state condition. In order to perform this evaluation, the levels of indoor air-borne particles were measured at the breathing zone for seated people (1.10m from the ground), and at the exhaust (2.60m from the ground) simultaneously, under six different pre-defined values of air temperature at the occupied zone (0.60m from the ground). These concentration levels have allowed calculating the contaminant removal effectiveness index, CRE, in many points of the ambient. A similar analysis was developed for the concentrations of CO2 in the second part of the experiment. At the same time, the air temperature and air velocity were measured in six different levels and at fourteen points of the ambient. The low concentration levels of total suspension particle (under 0.035 mg/m³) have shown that this system doesn\'t disperse air contaminants indoors. The CRE indexes near or above 1.0, for both total suspension particle and CO2, have confirmed the ventilation effectiveness of this underfloor air distribution system under all the operational conditions.
|
454 |
Impacto na ventilação e aeração pulmonar após remoção de derrame pleural neoplásico: um estudo com tomografia de impedância elétrica / Impact of lung ventilation and aeration after a therapeutic pleural aspiration of a malignant effusion: a study using electrical impedance tomographyAlves, Sergio Henrique Saraiva 15 March 2013 (has links)
INTRODUÇÃO: O primeiro passo na presença de derrame pleural maligno é a aspiração terapêutica do líquido para alívio dos sintomas e avaliar indicação de pleurodese. Infelizmente, em seres humanos a re-aeração e re- ventilação pulmonar após a retirada de líquido pleural foi avaliada apenas indiretamente. A tomografia de impedância elétrica (TIE) é uma técnica precisa que já foi extensivamente validada para quantificar aeração e ventilação pulmonar em tempo real e à beira-leito. O conhecimento das alterações em aeração e ventilação pulmonar após a retirada do líquido pleural é essencial para a compreensão da evolução clínica, objetivando novos esquemas de pleurodese e novos indicadores de reexpansão pulmonar. OBJETIVOS: Avaliar a aeração, ventilação e sincronia ventilatória antes e durante a primeira hora após a aspiração de um derrame pleural maligno. Objetivos secundários: correlacionar a re-aeração com variáveis que pudessem influenciá-la. Métodos: Critérios de inclusão: derrame pleural unilateral com necessidade de aspiração terapêutica e superior a 500 mL. Os sinais e imagens da TIE foram adquiridos em seis períodos diferentes: antes da aspiração pleural, imediatamente, 15, 30, 45 e 60 minutos após a aspiração. A re-aeração foi avaliada pela variação no valor da impedância (Z) ao final de uma expiração relaxada, enquanto a re-ventilação foi avaliada através da variação da impedância no volume corrente. Também medimos a sincronia entre os pulmões usando o ângulo de fase. Finalmente, correlacionamos à re-aeração final com o volume retirado, ângulo de fase inicial e elastância pleural. O pulmão afetado pelo derrame foi nomeado como ipsilateral e o não afetado como contralateral. RESULTADOS: Foram incluídos 22 pacientes. O volume médio aspirado foi 1438 ml. No pulmão ipsilateral, a média no final da expiração valor Z aumentou para 173,5 ± 122,3, imediatamente após a aspiração pleural (p <0,001), e a análise individual revelou que todos os pacientes ganharam re-aeracão pulmonar imediatamente, sem mais re-aerações após. O mesmo comportamento, mas com uma menor magnitude foi encontrado no pulmão contralateral. Na avaliação da re-ventilação, os pulmões ipsilateral e contralateral mostraram resultados heterogêneos, alguns aumentaram a ventilação, outros diminuíram ou mantiveram-na inalterada. Antes da aspiração pleural, a média do ângulo de fase foi de 93 ± 71 graus e diminuiu para 20 ± 30 graus, imediatamente após a aspiração pleural (p <0,001), sem outras alterações após. A re-aeração final correlacionou-se apenas com o volume de derrame aspirado (R2 = 0,49, p <0,01). CONCLUSÃO: Após a aspiração de derrame pleural unilateral neoplásico em pulmões não encarcerados, a re-aeração pulmonar ocorre imediatamente nos pulmões ipisilateral e contralateral, sem mais re-aeração durante a hora seguinte. As mudanças na re-ventilação mostram altas variações individuais. Há uma assincronia ventilatória entre os pulmões, que é imediatamente revertida pela aspiração pleural. A única variável correlacionada com a re-aeração do pulmão afetado é o volume de derrame drenado / INTRODUCTION: The first procedure in the management of a malignant pleural effusion is a therapeutic pleural aspiration to relieve symptoms and assess pleurodesis indication. Unfortunately, in humans the pulmonary re- aeration and re-ventilation after a pleural aspiration was evaluated only indirectly. Electrical impedance tomography (EIT) is an accurate, non- invasive and bedside method that has been extensively validated to quantify lung ventilation and aeration. The knowledge of changes in lung aeration and ventilation after a therapeutic pleural aspiration is essential to understand the clinical course, to propose new lung reexpansion predictors and pleurodesis schemas. OBJECTIVE: To measure the lung re-aeration, re-ventilation and ventilatory synchrony before and over the first hour after a therapeutic pleural aspiration for a malignant pleural effusion. As secondary objectives we correlate the lung re-aeration with variables that could influence them. METHODS: The inclusion criteria were the need of a therapeutic pleural aspiration of a unilateral effusion over 500 mL. EIT signals and images were acquired in six different periods: before the pleural aspiration, immediately and 15, 30, 45 and 60 minutes after the aspiration. The re-aeration was evaluated through the change in the end-expiratory lung impedance (Z), while the re-ventilation was evaluated through the change in tidal impedance. We also measure the ventilator synchrony between lungs using the phase angle. Finally we correlated the final re-aeration with the effusion volume drained, pleural elastances and baseline phase angle. The lung affected by the effusion was nominated as ipsilateral and the non-affected as contralateral. RESULTS: We included 22 patients. The mean volume of aspirated effusion was 1438 ml. In the ipsilateral lung, the mean end- expiratory Z value increased to 173.5 ± 122.3 immediately after the pleural aspiration (p < 0.001) and the individual analysis revealed that all patients re- aerated the lung immediately without further re-aeration thereafter. The same behavior but with a lower magnitude was found in the contralateral lung. The ipsilateral and contralateral lung re-ventilation showed heterogeneous results with patients increasing the ventilation, while others decreased or kept the ventilation unchanged. Before the pleural aspiration, the mean phase angle was 93 ± 71 degrees and decreased to 20 ± 30 degrees immediately after the pleural aspiration (p < 0.001), without further changes thereafter. The final re-aeration only correlated to the volume of effusion aspirated (R2 = 0.49; p < 0.01). CONCLUSION: In untrapped lungs, a pleural aspiration of a unilateral malignant pleural effusion causes an immediate re-aeration of the lung affected by the effusion and even of the contralateral lung, without further re-aeration over the next hour. The changes in ventilations show high individual variations. There is a ventilatory asynchrony between lungs that is immediately reversed by the aspiration. The only variable correlated to re- aeration of the affected lung is the effusion volume drained
|
455 |
Impacto da sedação intermitente ou interrupção diária da sedação em pacientes sob ventilação mecânica / Daily sedative interruption versus intermittent sedation in mechanically ventilated critically ill patientsNassar Junior, Antonio Paulo 22 September 2015 (has links)
Introdução: Interrupção diária da sedação e sedação intermitente são efetivas na redução do tempo de ventilação mecânica. No entanto, a superioridade de uma em relação à outra não foi ainda determinada. Nosso objetivo foi comparar a interrupção diária da sedação e a sedação intermitente quanto à duração da ventilação mecânica em uma unidade de terapia intensiva (UTI) com baixa densidade de pessoal de enfermagem. Métodos: Pacientes adultos com expectativa de permanecerem por mais de 24h em ventilação mecânica foram randomizados, em um centro único, à interrupção diária da infusão de sedativos e opioides ou à sedação intermitente. Em ambos os casos, o objetivo era manter os pacientes em nível de SAS (Sedation Agitation Scale) 3 ou 4, ou seja, os pacientes deveriam estar calmos ou serem facilmente despertos com estímulo verbal ou leve sacudida. O desfecho primário foi número de dias livres da ventilação mecânica em 28 dias. Os desfechos secundários foram mortalidade na UTI e hospitalar, incidência de delirium, carga de trabalho da enfermagem, extubação acidental e stress psicológico seis meses após a alta da UTI. Resultados: Foram incluídos 60 pacientes. Não houve diferenças quanto ao número de dias livres em 28 dias entre interrupção diária da sedação e sedação intermitente (mediana: 24 vs. 25 dias, P = 0,160). Também não houve diferenças quanto à mortalidade na UTI (40 vs. 23,3%, P = 0,165) ou hospitalar (43,3 vs. 30%, P = 0,284), incidência de delirium (30 vs. 40%, p = 0,472), extubação acidental (3,3 vs. 6,7%, P = 0,514) e stress psicológico seis meses após a alta da UTI. A carga de trabalho de enfermagem não foi diferente entre os dois grupos, mas reduziu-se no quinto dia de internação na UTI em comparação com o primeiro dia [Nurse Activity Score (NAS) no grupo sedação intermitente foi 54 no dia 1vs. 39 no dia 5, P < 0.001; NAS no grupo interrupção diária da sedação foi 53 no dia 1 vs. 38 no dia 5, P < 0.001]. As dosagens de fentanil e midazolam por paciente foram maiores no grupo interrupção diária da sedação. O volume corrente foi maior no grupo sedação intermitente durante os primeiros cinco dias de internação na UTI. Conclusões: Não houve diferenças quanto ao número de dias livres de ventilação mecânica em 28 dias entre os grupos. Sedação intermitente associou-se a um menor uso de sedativos e opioides / Introduction: Daily sedative interruption and intermittent sedation are effective in abbreviating the time on mechanical ventilation. Whether one is superior to the other has not yet been determined. Our aim was to compare daily interruption and intermittent sedation during the mechanical ventilation period in a low nurse staffing intensive care unit (ICU). Methods: Adult patients expected to need mechanical ventilation for more than 24 hours were randomly assigned, in a single center, either to daily interruption of continuous sedative and opioid infusion or to intermittent sedation. In both cases, our goal was to maintain a Sedation Agitation Scale (SAS) level of 3 or 4; that is patients should be calm, easily arousable or awakened with verbal stimuli or gentle shaking. Primary outcome was ventilator-free days in 28 days. Secondary outcomes were ICU and hospital mortality, incidence of delirium, nurse workload, self-extubation and psychological distress six months after ICU discharge. Results: A total of 60 patients were included. There were no differences in the ventilator-free days in 28 days between daily interruption and intermittent sedation (median: 24 versus 25 days, P = 0.160). There were also no differences in ICU mortality (40 versus 23.3%, P = 0.165), hospital mortality (43.3 versus 30%, P = 0.284), incidence of delirium (30 versus 40%, P = 0.472), self-extubation (3.3 versus 6.7%, P = 0.514), and psychological stress six months after ICU discharge. Also, the nurse workload was not different between groups, but it was reduced on day 5 compared to day 1 in both groups (Nurse Activity Score (NAS) in the intermittent sedation group was 54 on day 1versus 39 on day 5, P < 0.001; NAS in daily interruption group was 53 on day 1 versus 38 on day 5, P < 0.001). Fentanyl and midazolam total dosages per patient were higher in the daily interruption group. The tidal volume was higher in the intermittent sedation group during the first five days of ICU stay. Conclusions: There was no difference in the number of ventilator-free days in 28 days between both groups. Intermittent sedation was associated with lower sedative and opioid doses
|
456 |
"Avaliação e comparação de diferentes tipos de trocadores de calor e umidade" / Evaluation and comparison among different heat and moisture exchangersLucato, Jeanette Janaina Jaber 30 June 2005 (has links)
As tarefas de umidificação e aquecimento do ar inspirado podem ser realizadas por meio de trocadores de calor e umidade (HMEs - Heat and moisture exchangers). Os objetivos do nosso estudo são avaliar e comparar a capacidade de umidificação e aquecimento de oito diferentes tipos de HMEs em um modelo experimental com pulmão animal isolado e avaliar o impacto de cada um dos HMEs na ventilação alveolar em um modelo mecânico do sistema respiratório, com adição de CO2 a um fluxo de 0,65L/min. Os níveis de umidade e temperatura foram medidos durante a situação controle (nenhum HME) e com os diferentes HMEs quando volume corrente; freqüência respiratória e fluxo foram variados. A recuperação da umidade absoluta da expiração durante a próxima inspiração (% RAH) foi calculada. A % RAH aumentou com o uso do HME comparado ao controle. O volume corrente teve um significante efeito na % RAH, o que não ocorreu com alterações na frequência respiratória ou fluxo. O aumento do ETCO2 foi proporcional ao aumento do espaço morto dos HMEs. As alterações de fluxo ou a saturação dos HMEs não determinaram relevantes alterações no ETCO2 / When tracheal intubation is necessary during ventilatory support, the physiological mechanisms of heating and humidifying the inspired air are supressed, so it is vital the preconditioning of the inspired gases with the goal of offering water and heat contents similar to those normally provided by the upper airways. These tasks of humidification and heating can be accomplished through the use of heat and moisture exchangers (HMEs). Objectives: 1- Evaluate and compare the humidification and heating capacity of eight different types of HMEs in a respiratory system analog using preserved swine lung. 2- Evaluate the impact of each one of the tested HMEs over alveolar ventilation in a mevhanical model of the respiratory system
|
457 |
Um estudo sobre a simulação computacional da ventilação cruzada em habitações e sua aplicação no projeto arquitetônico. / A study on computer simulation of cross ventilation in dwellings and its application in architectural design.Motezuki, Fabio Kenji 27 May 2009 (has links)
Nos últimos anos, devido à crescente preocupação com a sustentabilidade, foram despendidos mundialmente grandes esforços para a redução do consumo de energia pelos sistemas prediais. Em países tropicais como o Brasil, a ventilação natural é uma maneira efetiva e econômica para melhorar o conforto térmico dentro de habitações. Ela contribui para diminuir o uso do condicionamento de ar e renovar o ar da edificação, ajudando a reduzir as chances de se ter a Síndrome do Edifício Doente (Sick Building Syndrome SBS) e melhorando a qualidade do ar interno (Indoor Air Quality IAQ). Para tirar proveito destas vantagens da ventilação natural, o comportamento do fluxo de ar dentro da edificação deve ser analisado considerando o clima local. Existem diversos códigos computacionais baseados na Dinâmica de Fluidos Computacional (Computational Fluid Dynamics CFD) que podem ser utilizados para esta finalidade, no entanto, o CFD é um campo que requer conhecimentos altamente especializados e experiência prática para se obter bons resultados e este conhecimento geralmente está além da formação da maioria dos engenheiros e arquitetos. Com base nas dificuldades listadas e na necessidade de complementar a formação de engenheiros e arquitetos nesta área do conhecimento, este trabalho está focado em dois objetivos: o primeiro é implementar um simulador numérico computacional baseado no algoritmo Solution Algorithm for Transient Fluid Flows SOLA e as condições de contorno necessárias para a simulação da ventilação, sendo que a validação do simulador foi realizada por comparação com resultados numéricos e experimentais existentes na literatura. O segundo objetivo é propor uma ferramenta prática para a análise da ventilação natural na fase de projeto, com uma abordagem baseada na teoria de sistemas nebulosos, para identificar as melhores configurações de aberturas para um dado leiaute. Para isto, adotou-se a idéia utilizada por Givoni em seu estudo experimental: o espaço interno de uma sala é dividido em subdomínios onde a velocidade média do ar, sob diversas configurações de aberturas, é registrada. Como as velocidades médias refletem bem a eficácia da ventilação no subdomínio, elas formam a base para a definição espacial da função de pertinência para boa circulação de ar dentro da sala, considerando cada configuração de abertura. No entanto, ao invés de usar resultados experimentais, uma série de simulações computacionais baseadas em CFD, foram executadas para compor um banco de dados para avaliação das funções de pertinência. Por outro lado, temos o leiaute, que é produzido durante a concepção do projeto. Na medida em que o leiaute provê as informações para elaborar os requisitos do fluxo de ar, a função de pertinência relacionada ao fluxo de ar em cada subdomínio deve ser avaliada baseada no leiaute e nos requisitos do usuário. Acertando os requisitos providos pelo leiaute com a eficácia do fluxo de ar provido pela configuração de abertura, pode ser identificada a configuração que melhor se adapta ao leiaute. Nos casos analisados neste trabalho, o método mostrou-se promissor, indicando a configuração típica que melhor atende aos requisitos de projeto com uma boa conformidade com os resultados obtidos pela simulação da sala completa, incluindo a mobília. / In the last years, due to the concerns on sustainability, a great effort in energy saving of building systems is being carried out worldwide. In tropical countries such as Brazil, the natural ventilation is an effective and economical option to improve thermal comfort inside the dwellings, to avoid the use of costly HVAC systems, and to renew the indoor air, contributing to mitigate the Sick Building Syndrome (SBS) and to improve the Indoor Air Quality (IAQ). In order to take advantage of the natural ventilation, the behaviors of the airflow inside the buildings must be analyzed considering the local climate. There are many computer simulation codes based on Computational Fluid Dynamics (CFD) that may be adopted for this purpose, however, CFD is a field that requires highly specialized knowledge and experience to achieve good results and this expertise, which is needed to obtain reliable numerical results, is generally beyond the formation of the most part of architects and engineers. Owing to these difficulties and on the necessity to form engineers and architects in this area of knowledge, this work is focused in two main objectives: The first one is to implement a numeric computational simulation program based on Solution Algorithm for Transient Fluid Flows (SOLA) and the boundary conditions needed to simulate ventilation. The validation of the code is made by comparing the numerical results with results obtained using numerical or experimental methods published by other authors. The second objective is to propose a practical tool for the analysis of natural ventilation in the design of dwellings, with an approach based on the concepts of the Fuzzy Systems Theory to identify the best configurations of the openings for a given layout. For this, the idea used by Givonis experimental study is adopted: the inner space of a room is divided in sub-domains whose mean air velocities under different opening configurations are recorded. As the mean velocities reflect very well the effectiveness of the ventilation in the sub-domain, they form the basis for the definition of spatial distribution of the membership function for good air circulation inside the room concerning each opening configuration. However, instead of the experimental ones, a series of computer simulations were carried out to build a database for the assessment of the membership functions. On the other hand, we have the sketch of the layout, which is produced during the conceptual stage of design. As the layout provides the information about the requirements for the airflow, the membership function regarding the desirable air flow for each sub-domain might be assessed based on the layout and considering the user\'s requirements. By matching the requirements provided by the layout with the effectiveness of the airflow provided by the opening configurations, the opening configuration that best fits the layout can be identified. In the cases analyzed in this work, the method shows promising results. The typical configuration that best fits the design requirements with a good conformity with the results was obtained by full room simulation, including the furniture.
|
458 |
Avaliação da qualidade da assistência à saúde quanto às medidas de prevenção e controle de pneumonia associada à ventilação mecânica / Evaluation of quality of health care regarding the measures of prevention and control of ventilator-associated pneumoniaSilva, Leandra Terezinha Roncolato da 10 September 2010 (has links)
Os serviços de saúde vêm desenvolvendo programas e ações visando a qualificação de seus processos de trabalho com intuito de reduzir, eliminar e prevenir deficiências da qualidade e que também atendam às necessidades e expectativas dos usuários. Diferentes estratégias de avaliação das práticas em saúde têm sido adotadas, permitindo a identificação das condições em que as práticas assistenciais são executadas. As infecções hospitalares constituem risco significativo à saúde dos usuários e, dentre estas, a pneumonia (PNM) assume particular importância, dada a prevalência e mortalidade a ela associadas, especialmente quando acomete pacientes graves internados em unidades de terapia intensiva (UTI). Para avaliação dos processos de trabalho, a literatura recomenda a utilização de indicadores que avaliem não só a estrutura, como também o processo e o resultado. Assim, este estudo objetivou avaliar a qualidade da assistência à saúde prestada em uma UTI, quanto ao uso das medidas de prevenção e controle de PNM em pacientes de alto risco submetidos à ventilação mecânica. Trata-se de um estudo descritivo exploratório, com abordagem quantitativa, realizado na UTI adulto de um hospital público de ensino de grande porte e nível terciário. Os sujeitos da pesquisa foram os pacientes internados na unidade sob assistência ventilatória invasiva com rebaixamento de consciência e/ou nutrição por sondas digestivas. Os dados foram coletados diariamente nos três turnos de trabalho utilizando o Indicador de Avaliação da Adesão às Medidas de Prevenção e Controle de Pneumonia em Pacientes de Alto Risco (IRPR) que monitora a aplicação de medidas de controle e prevenção de pneumonia hospitalar, a saber: decúbito elevado (entre 30 e 45º), fisioterapia respiratória, utilização de soluções estéreis nos equipamentos de terapia respiratória e adesão à rotina de troca dos inaladores estabelecida na instituição. Participaram do estudo, 38 pacientes, sendo 26 (68,42%) do sexo masculino e 12 (31,58%) do sexo feminino, com idades entre 19 e 82 anos e tempo de internação na UTI de 1 a 28 dias. Destes pacientes, 19 receberam alta, 3 (7,89%) permaneceram internados e 16 (42,10%) evoluíram para óbito. Foram realizadas 839 observações, relacionadas às medidas de prevenção e controle de PAVM conforme indicador IRPR. A conformidade geral a todas as medidas de prevenção e controle de PAVM correspondeu a 26,94%. A manutenção da cabeceira elevada e o atendimento de fisioterapia foram as medidas que mais influenciaram negativamente na obtenção dessa conformidade geral. Observou-se nos prontuários médicos que 13 (34,21%) pacientes desenvolveram PNM durante a internação. Foram calculados os índices de conformidade e não conformidade geral e de cada medida específica de prevenção e controle de PAVM para estes pacientes, com resultados semelhantes. Conclui-se que a conformidade alcançada nesta investigação não foi satisfatória (26,94%), embora algumas medidas isoladas que compõem o indicador IRPR tenha alcançado índices próximos a 100%. Este estudo possibilitou identificar a não adesão a determinadas práticas, embora instituídas na instituição investigada. Espera-se que a divulgação dos resultados propicie a adoção de novas estratégias educativas para equipe de saúde, visando desenvolver ações de melhoria contínua para práticas assistenciais. / The health services have been developing programs and actions aiming at the qualification their process of work with intent to reduce, to eliminate and to prevent deficiencies of the quality and that also meet the needs and expectations of users. Different strategies of evaluation of the practices in health have been adopted, allowing the identification of the conditions under which care practices are executed. The hospital infections constitute significant risk the health of the users and among these, the pneumonia (PNM) assumes private importance, given the prevalence and mortality it associated, especially when to assault patient serious interned in units of intensive therapy (UTI). For evaluation of the work processes, the literature recommends the use of pointers that not only evaluate the structure, as well as the process and the result. Thus, this study it objectified to evaluate the quality of the assistance to the health given in a UTI, how much to the use of the measures of prevention and control of PNM in patients of high risk submitted to the ventilation mechanics. This is a descriptive exploratory study, with quantitative boarding, carried through in the adult UTI of a public hospital of education of great transport and tertiary level. The study subjects were patients interned in the unit under invasive ventilators support with degradation of conscience and/or nutrition for digestive sounding leads. The data had been collected daily in the three turns of work using the Pointer of Evaluation of the Adhesion to the Measures of Prevention and Control of Pneumonia in at righ risk (IRPR) that monitors the application of measures of control and prevention of hospital pneumonia, namely: high decubitus (between 30 and 45º), respiratory therapy, use of barren solutions in the equipment of respiratory therapy and adhesion to the routine of exchange of inhalers established in the institution. Participated in the study, 38 patients, being 26 (68.42%) of masculine sex and 12 (31.58%) of the feminine sex, with ages between 19 and 82 years and time of internment in the UTI of 1- 28 days. From these patients, 19 they had 19 received high, 3 (7.89%) had remained interned and 16 (42.10%) had evolved for death. 839 comments, related to the measures of prevention and control of PAVM as indicating IRPR had been carried through. General conformity to all the measures of prevention and control of PAVM corresponded 26.94%. The maintenance of the high headboard and the attendance of therapy had been the measures that had more influenced negative in the attainment of this general conformity. It was observed in the medical handbooks that 13 (34.21%) patient ones had developed PNM during the internment. The indices of conformity and not general conformity and each specific measure of prevention and control of PAVM for these patients had been calculated, with similar results. One even so concludes that the conformity reached in this inquiry was not satisfactory (26.94%), some isolated measures that compose pointer IRPR have reached next indices the 100%. This study identified not adherence to certain practices, through established in the institution studied. It is hoped that the dissemination of results conducive to the adoption of new educational strategies for health staff in order to develop actions for continuous improvement to health care practices.
|
459 |
Integração da ventilação híbrida e da iluminação natural em saletas comerciais na cidade de São Paulo: influência de parâmetros de projeto / Daylighting and hybrid ventilation integration in cellular offices in the city of São Paulo: design parameters influence.Santesso, Caroline Antonelli 11 November 2016 (has links)
Atualmente, os edifícios selados hermeticamente e com as chamadas \"peles de vidro\" estão presentes em diversos países, e possuem, como consequência, um elevado consumo de energia elétrica para conseguir manter o conforto ambiental dos usuários. Contudo, é possível se beneficiar de uma maior eficiência energética nesses espaços através da combinação de soluções ativas e passivas. Esse estudo tem como objetivo principal avaliar a influência de parâmetros de projetos, tais como o formato da sala, tamanho e orientação das aberturas na fachada, no consumo de energia e no conforto visual em saletas comerciais com ventilação híbrida e integração da iluminação natural com a artificial na cidade de São Paulo. As saletas comerciais analisadas possuem uma área média, diferentes formatos e diferentes aberturas em uma só fachada, representando a solução arquitetônica mais comum encontrada nesse tipo de edifício. Através de análise energética realizada por meio do programa EnergyPlus e da análise lumínica com o programa DIVA-for-Rhino, verificou-se que o formato da sala é essencial para a decisão de um percentual de área de abertura na fachada (PAF) que consuma menos energia. Os resultados mostraram que o uso da ventilação híbrida sempre representou uma economia, atingindo uma redução de até 51% do consumo do ar condicionado para resfriamento e até 26% do consumo de energia total, com os PAF´s de 40, 70 e 100%. Seria interessante considerar elementos de proteção solar que não diminuam a eficácia da ventilação e iluminação naturais nesses ambientes, para se aliar o baixo consumo de energia com menores riscos de ofuscamento. Desta forma, o trabalho auxilia a incorporação destas estrategias para uma maior economia de energia no desenvolvimento do projeto arquitetônico desta tipologia de edifício comercial. / Nowadays, sealed airtight office buildings and so-called \"glass curtain wall\" are present in many countries, and have as a result a high consumption of electric energy to be able to maintain the environmental comfort of the users. However, the combination of passive and active strategies could improve the energy efficiency in these spaces. This study aims to evaluate the design parameters influence, such as rooms shape, the openings size and orientation, in the energy consumption and in the visual comfort in cellular offices with hybrid ventilation system and the integration of daylight and artificial lighting in São Paulo. The analyzed cellular offices have an average area, different shapes and different openings in one facade, representing the more common architectural characteristics found in this type of building in that context. Energy analyses in EnergyPlus and daylight studies using DIVA-for-Rhino were conducted. It was found that the rooms shape is essential for the determination of the window-to-wall-ratio (WWR) for reducing energy consumption. The results showed that the hybrid ventilation use always represented an economy, reaching reduction values up to 51% in the consumption of air conditioning for cooling and up to 26% in cellular offices total consumption, with a WWR of 40, 70 and 100%. It would be interesting to consider sun shading elements that do not reduce the effectiveness of natural ventilation and daylighting in these environments to combine low power consumption with a lower risk of glare. In this way, the work helps the incorporation of these strategies for save energy in the development of the architectural design of this type of commercial building.
|
460 |
Avaliação da conformidade de práticas de controle e prevenção da pneumonia associada à ventilação mecânica em um hospital público de ensino / Evaluation of compliance to the practices of control and prevention of ventilator-associated pneumonia in a public teaching hospitalIsa Rodrigues da Silveira Cabral de Menezes 11 December 2009 (has links)
Há praticamente consenso de que o processo de trabalho de controle e prevenção de infecção associada a serviços de saúde (IASS) atualmente hegemônico, pautado em indicadores de resultados, ou seja, eventos de IASS, são limitados para reconhecer as condições reais em que as práticas assistenciais são realizadas. Para tanto, avaliações processuais vêm sendo demandadas, para conhecer o grau de conformidade dessas ocorrências com as recomendações dadas por evidências científicas atualmente disponíveis. Este estudo teve a finalidade de avaliar a conformidade de práticas de controle e prevenção de pneumonia associada à ventilação mecânica (PAVM), por meio de indicadores clínicos processuais especificamente elaborados. Tais práticas corresponderam a: a) Avaliação da adesão às medidas específicas de prevenção e controle de PAVM: manutenção da cabeceira elevada a 30-45o; atendimento diário de fisioterapia respiratória; utilização de soluções estéreis para nebulizadores e inaladores; material de terapia respiratória em uso respeitando a rotina de troca estabelecida; b) Avaliação da adesão à realização de higiene bucal; c) Avaliação da adesão á higiene das mãos em procedimentos de aspiração orotraqueal, troca de cadarço da cânula orotraqueal e higiene bucal. Tratou-se de uma pesquisa aplicada envolvendo achados sobre o desempenho de práticas e procedimentos, buscando acessar sua qualidade, com delineamentos prospectivo, transversal e analítico. O cenário constituiu da UTI-Adulto de um Hospital Público de Ensino. A casuística correspondeu às oportunidades de avaliação das práticas selecionadas, realizadas por enfermeiros, auxiliares e técnicos de enfermagem e fisioterapeutas, nos três turnos de trabalho, em pacientes com intubação orotraqueal. A amostra baseou-se na conformidade esperada de 80%, acarretando 1748 avaliações distribuídas entre as práticas selecionadas, realizadas por meio de observação direta e registros em prontuários. Instrumentos e avaliadores foram submetidos à testes de aferição de concordância. O índice de conformidade geral obtido na adesão às medidas específicas de controle e prevenção de PAVM foi 68,0%, sendo que o turno da tarde apresentou o maior índice (72,4%) e o da manhã, o menor (63,2%). O índice de conformidade geral da prática de higiene bucal foi 60,1%, sendo que o turno da manhã apresentou o melhor índice (72,4%) e noturno, o menor (47,4%). Dentre as modalidades prescritas, a que apresentou maior conformidade foi a aplicação apenas de CHX 0,12%, em todos os turnos, mas somente o da manhã atingiu a conformidade mínima esperada (90%-manhã; 73,7%-noite; 72,9%-tarde). A modalidade menos acatada foi a escovação de dentes e aplicação de CHX 0,12%, em todos os turnos de trabalho (3,6%-noite; 28,6%-tarde; 33,3%-manhã). A conformidade geral da prática de higiene das mãos na realização dos procedimentos selecionados foi apenas 10,7%, sendo que a aspiração orotraqueal obteve maior conformidade (18,9%), seguindo-se troca de cadarço (7,9%) e higiene bucal (5,3%). O turno da manhã obteve maior adesão (16,7%) e o noturno a menor (3,1%). Nesta prática, o maior índice de conformidade foi obtido entre os fisioterapeutas (25,8%), seguindose os enfermeiros (15,6%) e, por último, auxiliares e técnicos (4,4%). Concluiu-se que embora as práticas avaliadas não tenham alcançado a conformidade geral esperada de 80% em nenhuma das avaliações, os resultados obtidos permitem inferir que as realidades observadas justificam a revisão de normas e rotinas instituídas, bem como a elaboração de estratégias que assegurem a adesão duradoura das práticas de controle e prevenção de PAVM, associado à análise contínua de infra-estrutura e condições de trabalho. Tornou-se evidente, também, a relevância de avaliações processuais constituírem atividades rotineiras de programas de controle e prevenção de IASS / There is a present consensus that the process of control and prevention of infection associated to health services (IAHS) based on result indicators is limited to recognize the real conditions in which assistance practices are performed. So, processual evaluations have been required to know the conformity level of these events in relation to recommendations given by scientific evidence now available. The aim of this study was to analyze the conformity of adhesion to the practices of control and prevention of ventilator-associated pneumonia (VAP) by means of specifically elaborated processual clinical indicators. These practices corresponded to: a) Evaluation of adherence to specific measures of prevention and control of VAP: maintaining the bed in a 30-45 degrees head-up position; daily respiratory physiotherapy; use of sterile solutions for nebulizers and inhalers; material of respiratory therapy in use respecting established routine of change; b) Evaluation of adherence to oral hygiene; c) Evaluation of adherence to hand-washing procedures when performing orotracheal aspiration, change of tape of the orotracheal cannula and oral hygiene. This was an applied research involving findings on performance of practices and procedures aiming to access its quality, through a prospective transversal and analytical design. It took place in an Adult-ICU of a Public Teaching Hospital. The casuistic corresponded to opportunities of evaluation of the selected practices performed by nurses, nursing assistant, nursing technicians and physiotherapists in the three work shifts in patients with orotracheal intubation. The sample was based on the expected conformity of 80%, with 1,748 evaluations distributed among the selected practices performed by means of direct observation and registers in patient records. Instruments and evaluators were submitted to tests for measuring compliance. The general conformity adhesion index obtained in the specific measures of control and prevention of VAP was 68.0%, of which the afternoon shift presented the greatest index (72.4%) and the morning shift with the lowest index (63.2%). The index of general conformity to the practice of oral hygiene was 60.1%, of which the morning shift presented the best index (72.4%) and the night shift with the worst (47.4%). Among the mentioned modalities the largest conformity was the CHX 0.12% application in all shifts, but only the morning shift reached the minimum expected conformity (90% in the morning; 73.7% at night and 72.9% in the afternoon). The less accepted modality was teeth cleaning and CHX 0.12% application in all shift works (3.6% at night; 28.6% in the afternoon; 33.3% in the morning). General conformity of hand hygiene practice in the performance of selected procedures was only 10.7%, the largest conformity represented by orotracheal aspiration (18.9%), followed by tape change (7.9%) and oral hygiene (5.3%). The morning shift obtained the best adherence (16.7%) and night shift the worst (3.1%). In this practice the best index of conformity was observed among the physiotherapists (25.8%), followed by nurses (15.6%) and the nursing assistants and technicians (4.4%). We concluded that the lack of the expected general adherence of 80% in all the evaluations justify a review of the rules and routines established, as well as the elaboration of strategies capable to assure a permanent adherence to the control and prevention practices of VAP, associated to a continuum analysis of infrastructure and work conditions. It was also evident the relevance of processual evaluations as routine activities of control and prevention programs of VAP
|
Page generated in 0.0432 seconds