• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 588
  • 10
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • Tagged with
  • 607
  • 297
  • 202
  • 134
  • 84
  • 78
  • 74
  • 73
  • 68
  • 65
  • 63
  • 61
  • 58
  • 57
  • 54
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
481

Análise experimental e numérica da concentração e dinâmica de partículas em sala cirúrgica e quarto de isolamento hospitalar. / Numerical and experimental analysis of particle concentration and dynamics in an operating room and isolation room.

Vilain, Rogério 15 December 2015 (has links)
A presente pesquisa tem como objetivo avaliar a eficiência de diferentes sistemas de ventilação no controle da transmissão aérea de agentes infecciosos em sala cirúrgica e em quarto de isolamento hospitalar. Para isso, foram desenvolvidos estudos experimentais e numéricos a partir de dados gerados em um hospital brasileiro de referência no tratamento de doenças respiratórias. Em uma sala cirúrgica, comparou-se o sistema de climatização existente (sistema de ventilação unidirecional) com um sistema split, adaptado na sala especialmente para este estudo. Em um quarto de isolamento compararam-se diferentes arranjos com ventilação natural (porta e janelas) e/ou mecânica (ventilador axial e unidade de descontaminação - filtro e exaustor). Em ambos os ambientes foram medidos parâmetros ambientais (velocidade do ar, temperatura do ar e intensidade de turbulência) e se realizou um estudo da concentração de partículas, mediante o uso de um gerador de partículas monodisperso. A partir dos dados gerados por meio desses procedimentos experimentais, para a sala cirúrgica, obteve-se o fator de proteção e, para o quarto de isolamento, a probabilidade de infecção utilizando o equacionamento proposto por Wells e Riley, bem como a taxa de decaimento de partículas. Os resultados experimentais subsidiaram a realização de um estudo numérico, que consistiu na avaliação dos campos de velocidade, temperatura e intensidade de turbulência do ar para os diferentes tipos de ventilação estudados e no estudo da dinâmica de partículas nos dois ambientes. Embora o sistema unidirecional seja, teoricamente, mais eficiente no controle das partículas, a metodologia de análise adotada evidenciou ineficiência do sistema na remoção de partículas devido a problemas na instalação e operação. Quanto ao sistema split, o presente estudo, como outros assemelhados, evidenciou a inadequação de seu uso em salas cirúrgicas. No quarto de isolamento a ventilação natural mostrou-se o método mais eficiente para a remoção de partículas e, consequentemente, o que mais reduz o risco de contaminação cruzada, conforme o equacionamento original de Wells-Riley. Para a sala cirúrgica foram obtidos valores experimentais do fator de proteção variando entre 0,10 e 0,52 e de -0,9 a +2,5 na análise numérica. Para o quarto de isolamento foram obtidos experimentalmente riscos de infecção entre 0,25 e 2,65%. Finalizando, este trabalho visa contribuir na proposição de uma metodologia experimental e numérica para a avaliação da dinâmica das partículas e, consequentemente, do risco de infecção por via aérea em ambientes hospitalares. / This research aims to evaluate the efficiency of different ventilation systems to control airborne transmission of infectious agents in a hospital operating room and isolation room. Experimental and numerical studies were carried out based on data generated in a Brazilian reference hospital for the treatment of respiratory diseases. In an operating room, an existing unidirectional air conditioning system (i. e., laminar air flow - LAF) was compared to a split system, adapted in the room especially for this study. In a respiratory isolation room, comparisons were drawn between different arrangements with natural ventilation (door and window) and/or mechanical ventilation (axial fan and decontamination unit - filter plus exhaust fan). In both rooms, environmental parameters (air speed, air temperature and turbulence intensity) were measured, and a study of particle concentration was developed employing a monodisperse aerosol generator. The data generated by these experimental procedures were used to calculate the protection factor for the operating room and the probability of infection for the isolation room, using the equation proposed by Wells and Riley, as well as the rate of particle decay. The experimental results were then used in a numerical study, which included evaluation of the fields of air velocity, temperature and turbulence intensity for different types of ventilation under study, as well as the analysis of particle dynamics in both environments. Although the unidirectional system is theoretically more effective for particle control, the methodology of analysis adopted revealed an inefficiency of this system in removing particles, due to installation and operation problems. Concerning the split system, this research - similarly to analogous studies - emphasizes the inadequacy of its use in operating rooms. In the isolation room, natural ventilation proved the most effective method for removing particles and, consequently, the one which reduces the most the risk of cross-contamination, according to the original Wells-Riley modeling. In the operating room were obtained experimental data for the protection factor ranging from 0.10 to 0.52 and from -0.9 to +2.5 in the numerical analysis. In the isolation room were obtained probabilities of infection between 0.25 and 2.65%. Finally, this work aims to contribute in proposing an experimental and numerical methodology for assessing the dynamics of particles and hence risk of airborne infection in hospital settings.
482

Contaminação aérea em cabines climatizadas: processo de avaliação e análise da influência de sistema de ventilação personalizado. / Airbone contamination in acclimatized cabins: process of evaluation and analysis of the influence of personalized ventilation system.

Conceição, Sandro Tavares 01 June 2012 (has links)
A disseminação de agentes infecciosos em ambientes interiores é um assunto de interesse da sociedade em geral e uma questão de saúde pública, tendo em vista os surtos recentes do vírus SARS, gripe suína, gripe aviária, etc. Em particular, o sistema com suprimento de ar individualizado têm se mostrado eficaz, atuando como barreira contra contaminação cruzada entre ocupantes. Diversas metodologias têm sido aplicadas nesses estudos, tal como gás traçador, geradores de partículas e simulação CFD, muitas vezes sem muito critério, ou com equipamentos e simulações excessivamente complexas. Neste contexto, o objetivo do presente trabalho é desenvolver um processo robusto e com menor complexidade do que os utilizados atualmente para avaliar a dispersão de contaminantes aéreos em ambientes interiores. O processo desenvolvido é aplicado em um estudo de caso onde a influência de um sistema de ventilação personalizado de cabine de aeronave é avaliado sobre a ótica da infecção cruzada. O trabalho contempla a realização de atividades de simulação computacional (CFD) e medições experimentais no ambiente interno de uma cabine de avião (mock-up), onde os campos de velocidade do ar são medidos com Velocimetria por Imagem de Partículas (PIV), partículas entre 2 e 10m são geradas com um gerador de aerossol e contadas com contadores ópticos portáteis. Obteve-se boa correlação entre os resultados numéricos e experimentais para o campo de velocidades e boa concordância qualitativa entre as contagens de partículas no experimento e nas simulações CFD Lagrangeanas. Observou-se, dentre outros aspectos, que a válvula gasper, tal como ensaiada no presente trabalho, contribui para a qualidade do ar na zona de respiração dos ocupantes sentados, promovendo um aumento nas taxas de deposição de partículas nas superfícies internas do mock-up. / The indoor dispersion of infections agents still concern the society, and has become a matter of public health, taken into account the outbreak of SARS in 2003, and the recent cases of influenza strains (H1N1, avian flu, SARS, etc). The use of personalized ventilation has improved the occupants\' air quality on recent evaluations, working as a contaminant spread barrier. Different kinds of methodologies are usually applied for those studies, such as tracer gas, particle generators and CFD simulations, sometimes without adequate criteria, or applying quite complex equipment and simulation methodologies such as transient analysis. Therefore, the main objective of the present work is to develop a robust method, and if possible less complicated than the current ones, to evaluate the dispersion of indoor airborne contaminants. Moreover, one\'s intend to apply the proposed method in a case study to evaluate the influence of a personalized ventilation system to the spread of indoor air contaminants. The study is composed by CFD simulations and experimental measurements inside an aircraft cabin mock-up, where the velocity and temperature field, as well as particle concentration are measured. Particle Image Velocimetry technique is used to analyse air flow velocities. Particles from 2 to 10µm are produced with aerosol generator and injected into the cabine. Finally, particle distributions are measured with hand held optical counters to evaluate air quality at the breathing zone. Good correlation between numerical and experimental results was obtained for velocity field, and adequate qualitative agreement was obtained for concentration field. One\'s conclude the investigated personalized ventilation system has improved the air quality around occupants breathing zone, mainly by increasing the deposition rates at the internal cabin surfaces.
483

Paredes trombe no Brasil: análise do potencial de utilização para aquecimento e refrigeração / Trombe walls in Brazil: analysis of feasibility of use for heating and cooling

Cavalcanti, Fernando Antonio de Melo Sá 13 November 2013 (has links)
Neste trabalho avaliou-se o desempenho térmico de um ambiente padrão a partir do uso de parede trombe com diferentes configurações e tipologias de uso, por meio de comparação com um ambiente de mesmas dimensões dotado de janelas convencionais, para oito cidades brasileiras, pois o potencial de utilização desta forma de estratégia passiva ainda é pouco estudado no Brasil. A parede trombe consiste em uma \"estufa\" entre uma parede de alta inércia térmica com aberturas inferiores e superiores e uma superfície envidraçada por onde o ambiente mantém contato com o exterior. Este dispositivo é capaz de absorver energia proveniente da radiação solar aquecendo o ar nesta estufa e este ar aquecido pode ser direcionado para o interior ou exterior da edificação a depender da finalidade. Este ar pode ser usado para aquecer o ambiente ou resfriá-lo por meio da ventilação natural. A análise deste trabalho se deu a partir de uma série de simulações computacionais utilizando o software EnergyPlus, versão 7.0 de modo a quantificar e classificar o desempenho térmico de um ambiente padrão dotado deste componente, sob as diversas configurações construtivas. Tanto para aquecimento quanto para resfriamento dos ambientes. A partir destas simulações, elaborou-se um modelo matemático simplificado capaz de quantificar a temperatura do ar no interior dos ambientes em que sejam utilizadas as paredes trombe de modo a tornar possível a utilização deste dispositivo na composição de edificações na fase de projeto, estimando seu desempenho sem que haja necessidade de novas simulações computacionais. O uso das paredes trombe melhorou o conforto térmico dos usuários em edificações localizadas no Brasil, a depender do clima onde estão inseridas, promovendo ventilação natural e aquecimento solar passivo, mesmo quando comparado com o modelo convencional de aberturas. Por fim foi elaborado um aplicativo para sistema Android em dispositivos móveis, possibilitando aos profissionais de projeto identificar a melhor tipologia para a localidade onde se deseja inserir este sistema e prever seu desempenho, contribuindo para que o potencial deste dispositivo seja investigado nas mais diversas regiões brasileiras. / This research evaluated the thermal performance of a standard environment from the use of Trombe wall with different settings and types of use, by comparison with a setting of the same dimensions equipped with conventional windows for eight Brazilian cities, because the potential the utilization of this passive strategy is still little studied in Brazil. A Trombe wall consists of a \"greenhouse\" between a wall of high thermal inertia lower and upper vents and a glazed area where the environment keeps contact with the outside. This device is capable of absorbing energy from solar radiation heating the air this greenhouse and this heated air can be directed to the interior or exterior of the building depending on the purpose. This air can be used to heat the room or cool it by means of natural ventilation. The analysis of this work was made from a series of computer simulations using EnergyPlus software, version 7.0 in order to quantify and classify the thermal performance of a standard environment with this component, under the various construction settings. Both for heating and for cooling environments. From these simulations, we elaborated a simplified mathematical model able to measure the air temperature within the environments in which they are used Trombe walls in order to make use of this device in the composition of buildings in the design stage as possible, estimating its performance without the need for new computer simulations. The use of Trombe walls improved thermal comfort of users in buildings located in Brazil, depending on the climate where they are located , providing natural ventilation and passive solar heating, even when compared with the conventional model of openings. Finally an app for Android system for mobile devices was developed, enabling professionals to identify the best design type to the location where you want to enter this system and predict its performance, contributing to the potential of this device is investigated in several Brazilian regions.
484

Ventilação não invasiva na prática clínica de um hospital terciário de grande porte: características demográficas, clínicas de fatores relacionados ao desfecho de pacientes internados em UTI / Non invasive ventilation in clinical pratice in a large tertiary hospital: demographical characteristics, clinics, and factors related to the outcome of patients in ICU

Travaglia, Teresa Cristina Francischetto 15 April 2010 (has links)
INTRODUÇÃO: A ventilação não invasiva (VNI) tem sido amplamente utilizada na prática clínica para o tratamento de insuficiência respiratória aguda (IRpA) e crônica. OBJETIVO: Observar longitudinalmente a rotina da utilização da VNI e estimar o seu impacto sobre os desfechos dos pacientes internados em UTI. METODOS: Estudo de coorte prospectivo de pacientes admitidos consecutivamente em 10 UTIs de um grande hospital público universitário. Durante 9 meses, foram estudados todos os pacientes com idade >= 18 anos, submetidos a VNI durante a permanência na UTI. RESULTADOS: Um total de 392 pacientes foram incluídos. A média (DP) de idade foi 56 (19) anos e 55% eram do sexo masculino. A média (DP) escore SAPS II foi de 36 (14). As indicações de VNI foram: pós-extubação (44%), IRpA (27%), fisioterapia respiratória(18%). A média do IPAP e do EPAP no último dia da VNI foi de 14 cmH2O e 8,8 cmH2O, respectivamente. A máscara facial foi utilizada em 93% dos casos e a máscara facial total em apenas 6%. A incidência de pneumonia foi de 5%. No desfecho do estudo, foi observado falência da VNI em 35% dos casos, taxa de mortalidade em 25% e o tempo de internação na UTI com uma mediana de 10 dias. CONCLUSÕES: A VNI pode ser bem sucedida se usada em pacientes selecionados. Muitos fatores foram associadas ao fracasso NIV: idade, SAPS II, IPAP, EPAP e valores FiO2 no último dia da VNI e presença de tosse e da necessidade de aspiração traqueal. A taxa de mortalidade e tempo de UTI foi maior no grupo que fracassou na VNI. / CONTEXT: Noninvasive ventilation (NIV) has been widely used in clinical practice in order to treat acute or chronic respiratory failure. OBJECTIVE: To observe the routine use of NIV and estimate the outcomes of this population. METHODS: A prospective cohort study of consecutively admitted patients in 10 ICUs of a large public university affiliated hospital. Over a 9 months period, we studied all patients with age >= 18 years, submitted to NIV during ICU stay. RESULTS: A total of 392 patients were included in this study. The mean (SD) age was 56(19) years, and 55% were males. The mean (SD) SAPS II Score was 36 (14). NIV indications were: post extubation (44%), acute respiratory failure (ARF)(27%), and chest physiotherapy (18%). The mean IPAP and EPAP at the last day of NIV was 14 cmH2O and 8.8 cmH2O respectively. The full face mask was used in 93% of cases, only 6% used total face mask. The incidence of pneumonia was 5%. The NIV failure rate was 35%, ICU mortality rate 25% and the median ICU stay 10 days. CONCLUSIONS: NIV can be successful in selected patients. Many factors were associated to NIV failure: age, and SAPS II, IPAP, EPAP and FiO2 values at the last day of NIV and presence of cough and the need for tracheal aspiration. Mortality rate and ICU length of stay were higher in NIV failure group.
485

Controlo da humidade em espaços de banho : comparação da eficiência energética de diferentes estratégias

Gomes, Filipe Alberto Vilaça January 2012 (has links)
Tese de mestrado integrado. Engenharia Mecânica. Faculdade de Engenharia. Universidade do Porto. 2012
486

Ingestão de bicarbonato de sódio e cloreto de amônio e seus efeitos sobre o ritmo de prova, desempenho e equilíbrio ácido-base em um teste contrarrelógio de ciclismo de 4km / Sodium bicarbonate and ammonium chloride ingestion and their effects on pacing, performance and acid-base balance during a 4-km cycling time trial

Carlos Rafaell Correia de Oliveira 09 June 2016 (has links)
Nós determinamos a influência da alcalose e acidose metabólica induzida sobre o ritmo de prova, gasto energético e desempenho durante um teste contrarrelógio de ciclismo de 4 km (TCR). Após um estudo preliminar (N=7) determinando as doses ótimas de cloreto de amônio (NH4Cl), bicarbonato de sódio (NaHCO3) e placebo (carbonato de cálcio, CaCO3), 11 ciclistas amadores realizaram um TCR de 4 km 100 min após ingerirem 0,15 g·kg-1 de NH4Cl, 0,3 g·kg-1 de NaHCO3 ou 0,15 g·kg-1 de CaCO3 (desenho de medidas repetidas, contrabalançado e duplo-cego). Comparado com placebo, a ingestão de NaHCO3 resultou em uma alcalose sanguínea pré-exercício (pH: + 0,06 ± 0,04, [HCO3-]: + 4,7 ± 2,6 mmol?L-1, excess de base: + 4,6 ± 2,4 mmol?L-1, P<0,05), enquanto que o NH4Cl resultou em uma acidose sanguínea (pH: - 0,05 ± 0,04, [HCO3-]: - 5,5 ± 2,9 mmol?L-1, excesso de base: - 5,3 ± 2,5 mmol?L-1, P<0.05), com essas diferenças permanecendo durante todo o teste. Apesar de nenhum desconforto gastrointestinal severo, os participantes adotaram um ritmo de prova significativamente mais conservador em NH4Cl comparado com placebo e NaHCO3, que foi acompanhado por uma redução na taxa de gasto energético anaeróbio (~ -14 %, P<0,05) e menor trabalho anaeróbio total (~ -13 %, P<0,05). Consequentemente, o desempenho foi prejudicado em NH4Cl (~ -7 %) comparado com as demais condições (P<0,05). O lactato plasmático, VCO2 e a PetCO2 foram menores e a VE/VCO2 maior durante o TCR em acidose do que em placebo e alcalose (P<0,05). Entretanto, não houve diferença para essas variáveis entre placebo e NaHCO3 (P<0,05). A acidose metabólica induzida diminuiu o ritmo de prova e o metabolismo anaeróbio, além de prejudicar o desempenho durante um TCR de 4 km, independente de desconforto gastrointestinal / We determined the influence of induced metabolic alkalosis and metabolic acidosis on pacing, energy expenditure and performance during a 4-km cycling time trial (TT). After a preliminary study (N=7) determining the optimal ammonium chloride (NH4Cl), sodium bicarbonate (NaHCO3), and placebo (calcium carbonate, CaCO3) doses, 11 amateur cyclists performed a 4-km TT 100 min after ingesting either 0.15 g·kg-1 of body mass of NH4Cl, 0.3 g·kg-1 of NaHCO3 or 0.15 g·kg-1 of CaCO3 (double-blind, counterbalanced and repeated-measures design). Compared with placebo, the NaHCO3 ingestion resulted in a pre exercise blood alkalosis (pH: +0.06 ± 0.04, [HCO3-]: +4.7 ± 2.6 mmol?L-1, base excess: +4.6 ± 2.4 mmol?L-1, P<0.05), while NH4Cl resulted in a blood acidosis (pH: -0.05 ± 0.04, [HCO3-]: -5.5 ± 2.9 mmol?L-1, base excess: -5.3 ± 2.5 mmol?L-1, P<0.05), with these differences remaining throughout the trial. Despite no gastrointestinal distress, participants adopted a significant more conservative pacing in NH4Cl compared with placebo and NaHCO3, which was accompanied by a reduced anaerobic energy expenditure rate (~ -14 %, P<0.05) and lower total anaerobic work (~ -13 %, P<0.05). Consequently, the performance was less in NH4Cl (~ -7 %) compared with other conditions (P<0.05). Plasma lactate, VCO2 and PetCO2 were lower and the VE/VCO2 higher during the TT in acidosis than in placebo and alkalosis (P<0.05). However, there was no difference for these variables between placebo and NaHCO3 (P>0.05). Induced metabolic acidosis slows pacing, decreases anaerobic metabolism and impairs performance during a 4-km TT, independent of gastrointestinal distress
487

Comparação entre dois modos ventilatórios em anestesia pediátrica : ventilação controlada a volume versus ventilação controlada a pressão

Ajnhorn, Fabiana January 2006 (has links)
Justificativa e Objetivos: Comparar as repercussões na mecânica respiratória e na troca gasosa em pacientes pediátricos submetidos à cirurgia ortopédica em posição lateral sob anestesia geral, utilizando-se dois modos de ventilação mecânica: controlada a volume (VCV) versus controlada a pressão (PCV), pois, em anestesia, o benefício de um modo em relação ao outro não está bem estabelecido. Método: Ensaio clínico randomizado, realizado entre julho de 2003 e junho 2005 envolvendo crianças (seis meses a 5 anos) submetidas à cirurgia de correção de pé torto congênito no Hospital de Clínicas de Porto Alegre. No modo VCV o volume corrente para se obter 10ml.kg-1 foi fixado. No modo PCV a pressão de pico inspiratória para se obter 10 ml.kg-1 foi fixada. Nos dois modos os pacientes recebiam PEEP 5cmH2O e relação I:E 1:2. Os grupos foram comparados quanto aos efeitos na mecânica ventilatória e na troca gasosa em 4 momentos ao longo da cirurgia com duração de 2 a 3 horas. Os testes t de Student, ANOVA, e Quiquadrado foram utilizados para comparar os grupos. Resultados: 37 cirurgias de correção de pé torto congênito entraram no estudo, sendo 18 no grupo VCV e 19 no PCV. Observou-se redução do volume corrente expirado ao longo da cirurgia em ambos grupos: VT em M1 ~119 ml enquanto em M4 foi ~113 ml (p=0,03), correspondendo a uma redução de 5% no VT ao longo da cirurgia. O número de intervenções (ajustes na freqüência respiratória) ao longo do tempo cirúrgico foi semelhante nos dois grupos. As demais variáveis não diferiram. Conclusões: durante anestesia geral, em crianças saudáveis, o modo ventilatório não influenciou a estabilidade cardioventilatória das crianças ao longo do tempo cirúrgico no presente estudo. / Objectives: To compare the repercussions on the respiratory mechanics and on the gaseous exchange of pediatric patients submitted to orthopedic surgery in lateral position under general anesthesia using two modes of ventilation: volume control ventilation (VCV) versus pressure control ventilation (PCV), because, in anesthesiology, the superiority of one over another is not well established. Methods: Randomized clinical trial, conducted from July of 2003 through June 2005, involving children (from 6 months to 5 years of age) submitted to surgery of correction of congenital clubfoot in the Hospital de Clínicas de Porto Alegre. In the VCV mode, tidal volume to get 10ml.kg-1 was fixed. In the PCV mode, peak inspiratory pressure to get 10 ml.kg-1 was fixed. In the two ventilations modes the patients received a PEEP of 5cmH2O and relation I:E 1:2. The groups were compared in relation to the effect in the mechanical ventilatory support and the gaseous exchange at 4 times through surgery with duration of 2 the 3 hours. Student t Test, ANOVA, and Qui-square had been used to compare the groups. Results: 37 surgeries of correction of congenital clubfoot were included in study, being 18 in the VCV group and 19 in the PCV. Reduction of the exhaled tidal volume along of the surgery in both groups was observed: VT M1 ~119 ml while in M4 was ~113 ml (p=0,03), corresponding to a reduction of 5% in the VT through the surgery. The number of interventions (adjustments in the respiratory frequency) along the surgical period was similar in the two groups. Remaining variables had not differed. Conclusions: In the present study, envolving healthy children submitted to the general anesthesia using two modes of mechanical ventilation, we did not observed any interferency in the cardio respiratory stability along the surgical period.
488

Efeito do treinamento muscular inspiratório sobre a capacidade funcional e a qualidade de vida de pacientes com hipertensão pulmonar crônica / The effect of inspiratory muscle training on fuctional capacity and quality of life in patients with chronic pulmonary hypertension

Ferreira, Glória Menz January 2012 (has links)
Introdução: Pacientes com hipertensão pulmonar (HP) além de apresentar redução da capacidade funcional, da qualidade de vida e da sobrevida, apresentam fraqueza dos músculos respiratórios, o que pode contribuir para o aumento dos sintomas de fadiga e dispneia. Objetivos: Verificar o efeito do treinamento muscular inspiratório (TMI) sobre a capacidade funcional, a qualidade de vida, a força muscular respiratória, pressão sistólica da artéria pulmonar, a função pulmonar e o nível de atividade física de pacientes com HP. Métodos: Doze pacientes com HP foram randomizados em um grupo controle (n=7) e um grupo TMI (n=5). O protocolo do TMI foi realizado durante 8 semanas. Foram feitas avaliações da pressão arterial pulmonar média, através do ecocardiograma; da qualidade de vida, através do questionário SF-36; da capacidade funcional, através do teste de caminhada de 6 minutos e da força muscular respiratória, através de transdutor de pressão. Todos os pacientes foram avaliados na fase pré e pós protocolo. Resultados: A força muscular inspiratória aumentou significativamente no grupo TMI quando comparado ao grupo controle (105,2±6,6 vs 82,9±6,1; p=0,01), e o escore de saúde mental avaliado pelo questionário SF-36 aumentou no grupo TMI (de 70,4±21,6 para 80±14,4; p=0,05). Entretanto a capacidade funcional não apresentou alteração após o protocolo de TMI de 8 semanas. Conclusão: O TMI é capaz de aumentar a força muscular inspiratória e melhorar a qualidade de vida, em relação a saúde mental, de pacientes com HP. / Introduction: Besides showing pulmonary hypertension (PH), decreased functional capacity, quality of life and survival, patients also present respiratory muscle weakness, which may contribute to increased fatigue and dyspnea symptoms. Objectives: Evaluate the effects of inspiratory muscle training (IMT) on functional capacity, quality of life, respiratory muscle strength, pulmonary artery pressure, pulmonary function and level of physical activity. Methods: Twelve chronic PH patients randomized to a control group (n = 7) and an IMT group (n = 5) were studied. The IMT program was performed for 8 weeks. The following measures were obtained before and after the program: respiratory muscle function; function capacity (6-min walk test); pulmonary artery pressure; quality of life (SF-36); and level de physical activity (IPAQ). Results: Maximal inspiratory pressure (PI,max) was higher in the IMT group than in the control group (105.2±6.6 vs 82.9±6.1; p=0.01), and the mental health score by SF-36 increased in de IMT group (from 70.4±21.6 to 80±14.4; p=0.05). However, the six-min walk test did not change after the IMT program. Conclusions: This study indicates that IMT results in improvement in inspiratory muscle strength and in the quality of life regarding PH.
489

Avaliação ecocardiográfica e da capacidade funcional por ensaio clínico randomizado dos efeitos agudos de dois modos de ventilação não-invasiva nasal na insuficiência cardíaca compensada

Mundstock, Lorena Contreras January 2008 (has links)
Introdução: Os efeitos agudos da ventilação não invasiva (VNI), comparando os modos continuous positive airway pressure (CPAP) versus bilevel positive airway pressure (BiPAP) devem ser melhor verificados em pacientes insuficiência cardíaca (IC) crônica. Objetivo: avaliar os efeitos agudos da VNI em pacientes com IC na resposta hemodinâmica da função cardíaca por ecocardiografia com Doppler Tissular e na avaliação da capacidade funcional através do teste de caminhada de 6 minutos (TC6min), utilizando modo CPAP versus BiPAP. Métodos vinte e seis pacientes portadores de insuficiência cardíaca selecionados de ambulatórios de cardiologia de hospitais-escola de Porto Alegre. Os pacientes foram randomizados para receber VNI pelos modos CPAP ou BiPAP durante 60 minutos. Foram realizados TC6min e ecocardiograma antes e após o uso da VNI. No modo CPAP foi utilizada pressão de 8 cmH2O, e no BiPAP foram 8 cmH2O de pressão inspiratória e 4 cmH2O de pressão expiratória. Resultados: o tempo de relaxamento isovolumétrico (TRIV) diminuiu após uso do CPAP (pré = 104,7±18,9 mseg versus pós = 60,48±19,2 mseg; p<0,05) e a fração de encurtamento (FS) diminuiu em ambos os modos (pré = 25,9±1,4% versus pós = 23,15±1,02%, P < 0,05). Entre os pacientes com fração de ejeção do ventrículo esquerdo (FEVE) >= 50%, houve aumento do diâmetro sistólico final do VE (DSFVE) (pré = 37,27±2,84mm versus pós = 41,8±2,77mm; p<0,05) e diminuição da FEVE (pré = 61,9±2,6% versus pós = 53,32±2,9%). A capacidade funcional não foi alterada com o uso da VMNI. Conclusão: O CPAP alterou significativamente o TRIV. A FEVE preservada influenciou os resultados da função contrátil do VE. A VNI não provocou alterações significativas sobre a capacidade funcional. / Introdução: The noninvasive ventilation (NIV) acute effects da ventilação não invasiva by comparing continuous positive airway pressure (CPAP) versus bilevel positive airway pressure (BiPAP) should be more investigated in patients with chronic heart failure (CHF). Objective: evaluate the acute effects of NIV in patients with heart failure (HF) in the hemodynamic response of the cardiac function through echocardiography with Tissue Doppler and in the assessment of functional capability through the 6-minute walk test (6MWT), using CPAP vs. BiPAP modes. Methods: twenty-six patients with HF recruited from outpatient clinics of Cardiology schoolhospitals in Porto Alegre. The patients were randomized to receive NIV through CPAP or BiPAP modes for 60 minutes. The 6MWT and echocardiogram were performed before and after the use of NIV. In CPAP mode, 8 cmH2O pressure was applied and in BiPAP mode 8 cmH2O inspiratory pressure and 4 cmH2O expiratory pressure were applied. Results: The isovolumic relaxation time (IVRT) was reduced after the use of CPAP (before = 104.7±18.9 msec. vs. after = 60.48±19.2 msec.; p<0.05) and the shortening fraction was reduced in both modes (before = 25.9±1.4% vs. after = 23.15±1.02%, p<0.05). Patients with left ventricle ejection factor (LVEF)>= 50% presented increased left ventricle end systolic diameter (LVESD) (before = 37.27±2.84mm vs. after = 41.8±2.77mm; p<0.05) and reduced LVEF (before = 61.9±2.6% vs. after = 53.32±2.9%). The functional capability was not altered with the use of NIV. Conclusion: The CPAP significantly altered the IVRT. The preserved LVEF affected the results of LV contractile function. The NIV did not cause any significant alteration to the functional capability.
490

Implantação de protocolo de prevenção da pneumonia associada à ventilação mecânica : impacto do cuidado não farmacológico

Vieira, Débora Feijó Villas Boas January 2009 (has links)
Contextualização: Na última década, houve um grande crescimento de ações de melhoria da qualidade assistencial e de promoção da segurança do paciente, com objetivo de diminuir a ocorrência de desfechos preveníveis, como a pneumonia associada à ventilação mecânica (PAVM). Embora existam várias diretrizes clínicas, ainda não há evidências suficientes para um consenso quanto aos cuidados não farmacológicos de prevenção (CNFP) a serem implantados e sua contribuição na redução da PAVM. Objetivos: Avaliar o impacto da implantação de CNFP na ocorrência da PAVM. Métodos: O estudo foi realizado com pacientes adultos, submetidos à ventilação mecânica (VM) por mais de 48 horas, internados em centro de tratamento intensivo clínico e cirúrgico, de 34 leitos. No primeiro artigo, é descrito um quase experimento com controles históricos, realizado no período de setembro de 2004 (pré-intervenção -20 meses) a dezembro 2007 (pós-intervenção – 20 meses). Constou do experimento a implantação do protocolo de prevenção da PAVM, com cuidados não farmacológicos. No segundo artigo, é descrito um estudo de coorte prospectiva de pacientes submetidos à VM no período de junho de 2006 a julho de 2007. Entre as onze medidas preventivas que fazem parte da rotina de cuidados, foram escolhidas seis para serem examinadas na rotina assistencial de pacientes submetidos à VM: manutenção da cabeceira elevada (HOB) de 30º a 45º; manutenção do circuito de VM (CVM) sem condensação e sujidade; manutenção de trocadores de umidade e calor (HME); monitorização da pressão do balonete (PB) do tubo endotraqueal entre 18 mmHg a 25 mmHg; realização da higiene oral (HO) e realização fisioterapia respiratória (FR). Estabeleceu-se um ponto de corte de 80% para adesão aos cuidados de prevenção. Considerou-se o CNFP como adequado quando, durante a internação, o paciente foi observado em frequência, igual ou maior de 80%. Resultados: No primeiro estudo, foram diagnosticados 367 episódios de PAVM durante os 40 meses, em um total de 20285 dias de ventilação mecânica. A taxa de PAVM baixou em 28,7%, ou seja, de 20,6 casos por 1.000 dias de ventilação no período pré-intervenção para 16 casos por 1.000 dias de ventilação nos 20 meses seguintes à intervenção (P<0,001). Na análise de regressão segmentada verificou-se uma redução abruta de nível significativa do desfecho (t = -2,506; p= 0,017), mas não foi observado uma redução de tendência significativa do desfecho (t= -1,670; p= 0,104). No segundo estudo, a adesão aos seis CNFP foi aferida em 5.781 observações, em 541 internações de pacientes submetidos à ventilação mecânica, com 111 casos de PAVM. Nas internações em que os pacientes receberam cuidados adequados de prevenção, houve redução na ocorrência de PAVM de 61% para a FR (OR=0,39; IC95%= 0,18 a 0,84); 43% para a HOB (OR=0,57; IC95%= 0,31 a 0,99). Houve interação entre HO e PB, com uma redução da razão de chances de 56% para HO (OR=0,44; IC95%= 0,24 a 0,82) e 58% para PB (OR=0,42; IC95%= 0,21 a 0,85). Na ausência de um desses dois cuidados, o outro presente passa a ser fator de risco. Estimouse a fração de risco atribuível para não realização de FR, HO, monitorização PB e manutenção da HOB em frequência adequada, implicando a ocorrência de, respectivamente, 49% (IC95%= 13% a 65%), 29% (IC95%= 9% a 39%), 32% (IC95%= 8% a 44%) e 9% (IC95%= 0% a 13%) das PAVM. Conclusão: Os cuidados de prevenção da PAVM implantados mostraram-se medidas tecnologicamente simples, exequíveis em qualquer realidade e de baixo custo, possibilitando redução no desenvolvimento de PAVM e aumento na segurança do paciente. / Context: In the past decade there has been a large increase in the number of measures aimed at improving service quality and promoting patient safety. Most of these measures have been aimed at reducing the incidence of preventable iatrogenic morbidities such as ventilator-associated pneumonia (VAP). While related clinical guidelines do exist, there is still little evidence to indicate which of the many non-pharmacological preventive care (NPPC) measures provide the best protection against VAP. Objectives: To evaluate the impact of NPPC interventions on the incidence of VAP. Methods: The population represented in this study are adult, intensive care patients, admitted without pneumonia, which required mechanical ventilation (MV) for at least 48 hours. The 34 bed intensive care center clinic and surgical is part of a public, university hospital in Porto Alegre, Brazil. The first article describes a quasi-experimental study done during the 40 months between September, 2004 and December, 2007. Halfway through this period a non-pharmacological, VAP prevention protocol was introduced to the routine care intubated patients. As such the control group are those patient treated prior to introduction of the protocol and the experimental group, those patients treated after its introduction. The second article describes a prospective study of cohort of patients requiring mechanical ventilation between June, 2006 and July 2007. Of the 11 NPPC interventions that make up the protocol, 6 were selected for this study: maintaining the head-of-bed elevation between 30º and 45º (HOB), maintaining the mechanical ventilation circuit (MVC) clean and dry, maintaining the heat moisture exchange (HME) equipment; maintaining endotracheal tube cuff pressure (CP) between 18 and 25 mmHg, realizing oral hygiene (OH) and doing respiratory physiotherapy (RP). These interventions were audited, for each patient during their entire length of stay, to measure compliance with the protocol. For each non-pharmacological preventive intervention, any patient receiving ≥8O% of the recommended frequency of care was considered to have received that intervention. Results: During a total of 20285 days of MV, 367 cases of VAP were diagnosed. The incidence of VAP fell 28.7% (p<0.001), between the 20 month pre-intervention period (20.6 cases/1.000 MV days) and the 20 month post-intervention periods (16 cases/1.000 MV days). In the analysis of segmented regression there was a significant abrupt reduction in the level of outcome (t = - 2.506; p=0.017), but reduction of tendency of the outcome was not significant (t= - 1.670; p= 0.104). In the second study compliance with the 6 non-pharmacological preventive interventions was measure by means of 5.781 observations in 541 patients of whom 111 developed VAP. Patients that received ≥8O% of the recommended frequency of a specific intervention exhibited a reduction in the risk of developing VAP: 61% for RP (OR= 0.39; CI95%= 0.18 to 0.84); 43% for HOB (OR= 0.57; CI95%= 0.31 to 0.99); 56% for OH (OR= 0.44; CI95%= 0.24 to 0.82) and 58% for CP (OR= 0.42; CI95%= 0.21 to 0.85). OH and CP maintenance are interdependent. In the absence of the other intervention each goes from being protective to being a risk factor. The VAP risk attributable to non-compliance in each of RP, OH, CP and HOB is estimated to be: 49% (CI95%= 13% to 65%), 29% (CI95%= 9% to 39%), 32% (CI95%= 8% to 44%) and 9% (CI95%= 0% to 13%) respectively. Conclusion: NPPC interventions are technologically simple, low cost that, in combination, provide a patient security and substantial level of protection against VAP.

Page generated in 0.0392 seconds