21

Beiträge zur räumlich aufgelösten Analyse mittels Scanning Laserablation-ICP-Massenspektrometrie unter besonderer Berücksichtigung von Schichtsystemen und Supraleitern

Plotnikov, Alexei 19 September 2004 (has links) (PDF)
Die vorliegende Arbeit stellt die Ergebnisse der methodologischen Entwicklung räumlich aufgelöster Analyse mittels Scanning Laserablation-ICP-Massenspektrometrie dar. Eine neue Behandlung zur Quantifizierung transienter analytischer Signale wurde für die Wiederherstellung von Konzentrationsprofilen vorgeschlagen. Die Anwendung der entwickelten Modelle auf die räumlich aufgelöste Analyse mittels LA-ICP-MS ermöglicht verbesserten Informationsgewinn und lässt dadurch eine höhere räumliche Auflösung erreichen. Die Anwendbarkeit der LA-ICP-MS für die räumlich aufgelöste Bestimmung der Stöchiometrie in supraleitenden Borokarbiden wurde untersucht. Der Einfluss apparativer Größen auf das analytische Signal wurde aufgeklärt, um die Messbedingungen zu optimieren. Zusätzlich wurden Fraktionierungseffekte untersucht, um die Ursache und deren Auswirkung auf die Analyse supraleitender Borokarbiden zu erklären. / This work represents the results of the methodological development of spatially resolved analysis by scanning laser ablation ICP mass spectrometry. A new approach to the quantification of transient analytical signals was proposed to reveal the concentration profile. An application of the developed models on spatially resolved analysis by LA-ICP-MS allows to gain more information from experimental data and hence to achieve better spatial resolution. The applicability of LA-ICP-MS to the spatially resolved determination of the stoichiometry of superconducting borocarbides was investigated. The effect of experimental parameters on analytical signals was elucidated in order to optimize the experimental conditions. In addition, fractionation effects were investigated to identify the causes for fractionation and their influence on the analysis of superconducting borocarbides.
22

Entwicklung eines integrierten Mikroresonators für die kernmagnetische Resonanzspektroskopie kleinster Probenvolumen

Leidich, Stefan 26 February 2010 (has links)
In der vorliegenden Arbeit wird ein Mikroresonator für die kernmagnetische Resonanzspektroskopie kleinster Probenvolumen entwickelt. Der Resonator besteht aus einem Mikrodetektor und einer elektrisch steuerbaren Kapazität für den Resonanzabgleich. Beide Bauteile sind speziell an die Anforderungen des Messverfahrens angepasst. Der Mikrodetektor, welcher die Funktion der Erregung der Kernspins und die Detektion des Messsignals erfüllt, weist aufgrund seiner besonderen Geometrie ein weitgehend homogenes statisches Magnetfeld im Bereich des Probenvolumens auf. Daraus resultieren eine Verbesserung der spektralen Auflösung und eine Steigerung der Empfindlichkeit. Die elektrisch steuerbare Kapazität weist eine hohe elektrische Güte und eine hohe Spannungsfestigkeit auf, wodurch die Verwendung von hohen Pulsleistungen möglich ist. Der Nachweis der Funktionalität des Systems erfolgt durch die Integration des Mikroresonators in einen Probenkopf, welcher zur Messung von Test- und Referenzsignalen eingesetzt wird. Anhand der Messwerte wird gezeigt, dass die neue Entwicklung eine sehr hohe Empfindlichkeit und eine deutlich höhere spektrale Auflösung als andere Detektorsysteme dieser Art aufweist und somit besonders gut für die Messung von sehr kleinen Probenvolumen geeignet ist. / The thesis describes the development of a micro resonator for nuclear magnetic resonance (NMR) spectroscopy of very small sample volumes. The resonator consists of a microcoil and an electrically adjustable capacitance for resonance tuning. Both components are specially designed for the purpose of NMR. The microcoil excites the nuclear spins and detects the measurement signal. Due to the special cylindrical geometry, the detector provides a very homogenous spatial distribution of the static magnetic field at the location of the sample. This leads to improved spectral resolution and increased sensitivity. The electrically adjustable capacitance provides a high quality factor and high voltage stability. Hence, short excitation pulses with high bandwidth can be applied. The components are integrated into a specially designed probe. The functionality of the system is demonstrated by test and reference measurements. The measurement results verify the high sensitivity and the high spectral resolution. Hence, the system is applicable and well suited for NMR measurements of small sample volumes.
23

Auflösungsvermögen und Genauigkeit der Kelvinsonden-Rasterkraftmikroskopie und deren Anwendung an molekularen Systemen

Zerweck-Trogisch, Ulrich 16 November 2007 (has links)
Die Arbeit befasst sich mit der Erforschung und Anwendung der Kelvinsonden-Rasterkraftmikroskopie. Die Technik wird bezüglich der Quantität der gemessenen Werte und der erzielbaren lateralen Auflösung untersucht und auf diverse Probensysteme angewandt. Die so erhaltenen nanoskopischen Werte werden mit markoskopischen Messergebnissen verglichen. Sowohl die elektrostatische Kraft zwischen der Messspitze und der Probenoberfläche als auch deren Gradienten können zur Minimierung der elektrostatischen Wechselwirkung herangezogen werden. Die Detektion des Kraftgradienten zum Aufbau eines Regelkreises erweist sich gegenüber der Kraftdetektion überlegen. Die experimentell ermittelten Befunde werden durch eine Rechnersimulation bestätigt. Diese zeigt die Möglichkeit von quantitativen Ergebnissen für laterale Objektgrößen im Bereich von einigen Nanometern. Im Experiment kann dies gezeigt werden. Es folgt die Anwendung der Kelvinsonden-Rasterkraftmikroskopie: Nanoskopisch ermittelte Werte der Austrittsarbeitsänderung von Metalleinkristall-Oberflächen durch die Adsorption von C_60 entsprechen Literaturwerten, die mit makroskopisch messenden Methoden ermittelt wurden. Sich zeitlich ändernde Oberflächenpotentiale von einer organischen Solarzelle und von lateral unterschiedlich dotiertem Silizium lassen sich quantitativ messen. Der sich bei der Adsorption von Oktadezyl-Phosphonsäure auf Glimmer und Graphit bildende elektrostatische Dipol wird untersucht und abgebildet. Das Wachstumsverhalten und die Austrittsarbeit der organischen Moleküle PTCDA und Alq_3 auf den teilweise mit KBr bedeckten Metallsubstraten Au und Ag wird untersucht. Schlussendlich wird gezeigt, dass mit der Kelvinsonden-Rasterkraftmikroskopie sogar der molekülinterne Dipol der vier Butyl-Gruppen von Tetra-3,5-di-ter-butyl-phenyl-Porphyrinen aufgelöst werden kann.
24

Beiträge zur räumlich aufgelösten Analyse mittels Scanning Laserablation-ICP-Massenspektrometrie unter besonderer Berücksichtigung von Schichtsystemen und Supraleitern

Plotnikov, Alexei 03 December 2003 (has links)
Die vorliegende Arbeit stellt die Ergebnisse der methodologischen Entwicklung räumlich aufgelöster Analyse mittels Scanning Laserablation-ICP-Massenspektrometrie dar. Eine neue Behandlung zur Quantifizierung transienter analytischer Signale wurde für die Wiederherstellung von Konzentrationsprofilen vorgeschlagen. Die Anwendung der entwickelten Modelle auf die räumlich aufgelöste Analyse mittels LA-ICP-MS ermöglicht verbesserten Informationsgewinn und lässt dadurch eine höhere räumliche Auflösung erreichen. Die Anwendbarkeit der LA-ICP-MS für die räumlich aufgelöste Bestimmung der Stöchiometrie in supraleitenden Borokarbiden wurde untersucht. Der Einfluss apparativer Größen auf das analytische Signal wurde aufgeklärt, um die Messbedingungen zu optimieren. Zusätzlich wurden Fraktionierungseffekte untersucht, um die Ursache und deren Auswirkung auf die Analyse supraleitender Borokarbiden zu erklären. / This work represents the results of the methodological development of spatially resolved analysis by scanning laser ablation ICP mass spectrometry. A new approach to the quantification of transient analytical signals was proposed to reveal the concentration profile. An application of the developed models on spatially resolved analysis by LA-ICP-MS allows to gain more information from experimental data and hence to achieve better spatial resolution. The applicability of LA-ICP-MS to the spatially resolved determination of the stoichiometry of superconducting borocarbides was investigated. The effect of experimental parameters on analytical signals was elucidated in order to optimize the experimental conditions. In addition, fractionation effects were investigated to identify the causes for fractionation and their influence on the analysis of superconducting borocarbides.
25

Comparison of image quality and spatial resolution between ¹⁸F, ⁶⁸Ga, and ⁶⁴Cu phantom measurements using a digital Biograph Vision PET/CT

Braune, Anja, Oehme, Liane, Freudenberg, Robert, Hofheinz, Frank, van den Hoff, Jörg, Kotzerke, Jörg, Hoberück, Sebastian 22 February 2024 (has links)
Background: PET nuclides can have a considerable influence on the spatial resolution and image quality of PET/CT scans, which can influence diagnostics in oncology, for example. The individual impact of the positron energy of ¹⁸F, ⁶⁸Ga, and ⁶⁴Cu on spatial resolution and image quality was compared for PET/CT scans acquired using a clinical, digital scanner. - Methods: A Jaszczak phantom and a NEMA PET body phantom were filled with ¹⁸F-FDG, ⁶⁸Ga-HCl, or ⁶⁴Cu-HCl, and PET/CT scans were performed on a Siemens Biograph Vision. Acquired images were analyzed regarding spatial resolution and image quality (recovery coefficients (RC), coefficient of variation within the background, contrast recovery coefficient (CRC), contrast–noise ratio (CNR), and relative count error in the lung insert). Data were compared between scans with different nuclides.- Results: We found that image quality was comparable between ¹⁸F-FDG and ⁶⁴Cu-HCl PET/CT measurements featuring similar maximal endpoint energies of the positrons. In comparison, RC, CRC, and CNR were degraded in ⁶⁸Ga-HCl data despite similar count rates. In particular, the two smallest spheres of 10 mm and 13 mm diameter revealed lower RC, CRC, and CNR values. The spatial resolution was similar between ¹⁸F-FDG and ⁶⁴Cu-HCl but up to 18% and 23% worse compared with PET/CT images of the NEMA PET body phantom filled with ⁶⁸Ga-HCl. - Conclusions: The positron energy of the PET nuclide influences the spatial resolution and image quality of a digital PET/CT scan. The image quality and spatial resolution of ⁶⁸Ga-HCl PET/CT images were worse than those of ¹⁸F-FDG or ⁶⁴Cu-HCl despite similar count rates.
26

Annexin A1 exerts renoprotective effects in experimental crescentic glomerulonephritis

Labes, Robert, Dong, Lei, Mrowka, Ralf, Bachmann, Sebastian, Vietinghoff, Sibylle von, Paliege, Alexander 30 May 2024 (has links)
Non-resolving inflammation plays a critical role during the transition from renal injury towards end-stage renal disease. The glucocorticoid-inducible protein annexin A1 has been shown to function as key regulator in the resolution phase of inflammation, but its role in immune-mediated crescentic glomerulonephritis has not been studied so far. Methods: Acute crescentic glomerulonephritis was induced in annexin A1-deficient and wildtype mice using a sheep serum against rat glomerular basement membrane constituents. Animals were sacrificed at d5 and d10 after nephritis induction. Renal leukocyte abundance was studied by immunofluorescence and flow cytometry. Alterations in gene expression were determined by RNA-Seq and gene ontology analysis. Renal levels of eicosanoids and related lipid products were measured using lipid mass spectrometry. Results: Histological analysis revealed an increased number of sclerotic glomeruli and aggravated tubulointerstitial damage in the kidneys of annexin A1-deficient mice compared to the wildtype controls. Flow cytometry analysis confirmed an increased number of CD45+ leukocytes and neutrophil granulocytes in the absence of annexin A1. Lipid mass spectrometry showed elevated levels of prostaglandins PGE2 and PGD2 and reduced levels of antiinflammatory epoxydocosapentaenoic acid regioisomers. RNA-Seq with subsequent gene ontology analysis revealed induction of gene products related to leukocyte activation and chemotaxis as well as regulation of cytokine production and secretion. Conclusion: Intrinsic annexin A1 reduces proinflammatory signals and infiltration of neutrophil granulocytes and thereby protects the kidney during crescentic glomerulonephritis. The annexin A1 signaling cascade may therefore provide novel targets for the treatment of inflammatory kidney disease.
27

MEMS-Laser-Display-System / MEMS Laser Display System

Specht, Hendrik 19 October 2011 (has links) (PDF)
In der vorliegenden Arbeit werden die im Zusammenhang mit der Strahlablenkung stehenden Systemaspekte der auf MEMS-Scanner basierenden Laser-Display-Technologie theoretisch analysiert und aus den Ergebnissen die praktische Implementierung eines Laser-Display-Systems als Testplattform vorgenommen. Dabei werden mit einem Ansatz auf Basis zweier 1D-Scanner und einem weiteren Ansatz mit einem 2D-Scanner zwei Varianten realisiert. Darüber hinaus erfolgt die Entwicklung eines bildbasierten Multiparametertestverfahrens, welches sowohl für den Test komplettierter Strahlablenkeinheiten bzw. Projektionsmodule als auch zum umfassenden und zeiteffizienten Test von MEMS-Scannern auf Wafer-Level geeignet ist. Mit diesem Verfahren erfolgt eine Charakterisierung der zwei realisierten Varianten des Laser-Displays. Ausgehend von den Eigenschaften des menschlichen visuellen Systems und den daraus resultierenden Anforderungen an das Bild sowie einer systemtheoretischen Betrachtung des mechanischen Verhaltens von MEMS-Scannern bildet die Ansteuersignalerzeugung für den resonanten Betrieb der schnellen und den quasistatischen Betrieb der langsamen Achse einen Schwerpunkt. Neben dem reinen digitalen Regler- bzw. Filterentwurf sowie mehreren Linearisierungsmaßnahmen beinhaltet dieser auch die Herleitung einer FPGA-basierten Videosignalverarbeitung zur Konvertierung von Scannpattern, Zeitregime und Auflösung mit einer entsprechenden Synchronisierung von Strahlablenkung und Lasermodulation. Auf Grundlage der daraus resultierenden Erkenntnisse über den Zusammenhang zwischen Scanner-/Systemparametern und Bildparametern werden Testbild-Bildverarbeitungsalgorithmus-Kombinationen entwickelt und diese, angeordnet in einer Sequenz, mit einem Kalibrierverfahren zu einem Testverfahren für MEMS-Scanner vervollständigt. Die Ergebnisse dieser Arbeit entstanden im Rahmen von industriell beauftragten F&E-Projekten und fließen in die andauernde Fortführung des Themas beim Auftraggeber ein.
28

Fast STED Microscopy / Schnelle STED-Mikroskopie

Lauterbach, Marcel 15 December 2009 (has links)
No description available.
29

MEMS-Laser-Display-System: Analyse, Implementierung und Testverfahrenentwicklung

Specht, Hendrik 20 May 2011 (has links)
In der vorliegenden Arbeit werden die im Zusammenhang mit der Strahlablenkung stehenden Systemaspekte der auf MEMS-Scanner basierenden Laser-Display-Technologie theoretisch analysiert und aus den Ergebnissen die praktische Implementierung eines Laser-Display-Systems als Testplattform vorgenommen. Dabei werden mit einem Ansatz auf Basis zweier 1D-Scanner und einem weiteren Ansatz mit einem 2D-Scanner zwei Varianten realisiert. Darüber hinaus erfolgt die Entwicklung eines bildbasierten Multiparametertestverfahrens, welches sowohl für den Test komplettierter Strahlablenkeinheiten bzw. Projektionsmodule als auch zum umfassenden und zeiteffizienten Test von MEMS-Scannern auf Wafer-Level geeignet ist. Mit diesem Verfahren erfolgt eine Charakterisierung der zwei realisierten Varianten des Laser-Displays. Ausgehend von den Eigenschaften des menschlichen visuellen Systems und den daraus resultierenden Anforderungen an das Bild sowie einer systemtheoretischen Betrachtung des mechanischen Verhaltens von MEMS-Scannern bildet die Ansteuersignalerzeugung für den resonanten Betrieb der schnellen und den quasistatischen Betrieb der langsamen Achse einen Schwerpunkt. Neben dem reinen digitalen Regler- bzw. Filterentwurf sowie mehreren Linearisierungsmaßnahmen beinhaltet dieser auch die Herleitung einer FPGA-basierten Videosignalverarbeitung zur Konvertierung von Scannpattern, Zeitregime und Auflösung mit einer entsprechenden Synchronisierung von Strahlablenkung und Lasermodulation. Auf Grundlage der daraus resultierenden Erkenntnisse über den Zusammenhang zwischen Scanner-/Systemparametern und Bildparametern werden Testbild-Bildverarbeitungsalgorithmus-Kombinationen entwickelt und diese, angeordnet in einer Sequenz, mit einem Kalibrierverfahren zu einem Testverfahren für MEMS-Scanner vervollständigt. Die Ergebnisse dieser Arbeit entstanden im Rahmen von industriell beauftragten F&E-Projekten und fließen in die andauernde Fortführung des Themas beim Auftraggeber ein.