• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 6
  • 4
  • 3
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 30
  • 30
  • 6
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Návrh optoelektrického snímače biologických tkání / Design of optoelectronic sensor for biological tissues

Balík, Zdeněk January 2014 (has links)
Biological tissues are optically inhomogeneous and absorbent materials. They are comprised of various structures such as cells, cell organelles, and various fiber structures. Due to these structures leads to different interactions with the light and phenomena such as absorption, scattering and polarization of light. Different ultrasonic, electromagnetic, electrical and optical methods are used for meat ageing detection. Muscles are turbid anisotropic media, they exhibit changes in electrical and optical properties according to the direction of the electrical and optical fields in the sample. The diploma work assesses the feasibility of impedance measurements for meat ageing detection and their comparison with optical measurement of scattered polarized light. Two different sample were used: pork chop slices and chicken breasts were used for their relative homogeneity. The electrical method is a promising method due to the possibility of getting much information and realizing cheap and fast enough measurement systems. The proposed optical method allows measure the rotation of polarization plane with meat ageing in the range of 95 degrees within considered period. Through the first promising results obtained in this thesis, a further work has to be provided to determine closer relationship between optical scattering characteristics, electrical anisotropy in ageing-related tissue structural properties.
22

Detekce průtoku pomocí optických interferenčních metod / Flow detection using optical intereference methods

Hoštáková, Nina January 2015 (has links)
The thesis deals with LSCI (Laser Speckle Contrast Imaging), an optical method utilizing laser speckle contrast for the estimation of blood flow changes. LSCI is non-invasive and technically not demanding approach, capabilities of which have not yet been fully exploited. The literature review part contains detailed description of the operating principle, imaging techniques, potential for medical applications with considering the limiting factors. The main aim of the thesis is to design and construct a complete LSCI system including appropriate phantoms able to simulate blood flow through the tissue. Imaging algorithms for the obtained data evaluation were implemented in Matlab® development enviroment. Finally, the created system was tested using different acquisition parameters as well as varying the image processing schemes. The resulting qualitative flow images were subsequently discussed and confronted with the theoretical assumptions.
23

Studium rozptylu a polarizace světla v biologické tkáni / Study of Scattering and Polarization of Light in Biological Tissue

Abubaker, Hamed Mohamed January 2013 (has links)
Tkáňová optika nabývá rychle na významu a přesná znalost optických vlastností biologických tkání je podstatná pro výzkum v biomedicíně i pro kontrolu kvality potravin. Jestliže je vzorek tkáně osvětlen, dochází k mnohonásobnému odrazu světla. V případě postmortem neživých tkání (maso) je rozměr buněk větší než vlnová délka použitého světla. Dochází k Mieovu rozptylu prošlého nebo zpět odraženého světla, v důsledku čehož se objevují různé polarizační stavy světla. Polarizační stavy světla rozptýleného na difúzním prostředí jsou experimentálně zkoumány a modelovány. V práci jsme provedli dva modifikované experimenty: rozptyl polarizovaného světla, které dvakrát prochází vzorkem (vpřed a vzad) a jen světla, které jen prochází vzorkem. Měření rozptýleného světla ukazuje, že dochází k depolarizaci a ke stáčení polarizační roviny, což obojí závisí na orientaci svalových vláken a stárnutí tkání postmortem. Mimo experimentů byl také proveden teoretický popis difúzní biologické tkáně a byla vypočtena radiační přenosová rovnice pomocí modifikované Monte Carlo metody, která zahrnuje polarizační stav světla (PLMC). Je ukázáno, že stupeň polarizace podstatně závisí na optických vlastnostech rozptylového prostředí. Výsledky ukazují, že stav polarizace světla na výstupu závisí na stavu polarizace světla před vzorkem a na optických vlastnostech a tloušťce vrstvy prostředí v průběhu jejího stárnutí. Je také provedena korelace změn polarizace na čerstvosti masa, i popis dynamického chování polarizace při stárnutí masa.
24

Voltage Controlled Current Source with Reduced Stray Capacitances Effect and Extended Impedance and Frequency Ranges

Nouri, Hanen 31 July 2024 (has links)
Bioimpedance spectroscopy is a non-invasive measurement technique in medical applications. It requires low amplitude current excitation to maintain safety. Designing a current source for this purpose is a challenge as it needs to maintain a stable and safe excitation current, below 0.5 mA, independent of the impedance and frequency. Various topologies of voltage controlled current sources exist in the literature, where the Enhanced Howland Current Source (EHCS) and the Dual HCS (DHCS) show advantages concerning low output current deviation and high output impedance. They are composed of operational amplifiers and resistors, where the operational amplifier's non-ideal characteristics, resistors' tolerance influence the circuit performance. In this thesis, we propose an analytical model to systematically select circuit components. Stray capacitances influence the circuit' performance. Thus, we propose a new structure of the Howland current source to eliminate their effects. We have thereby successfully grounded the measured impedance on a virtual ground and isolated it from stray capacitances. As a result, we achieve a wide working bandwidth of 5 MHz and 7 MHz for EHCS and DHCS, respectively. Moreover, the circuits can deliver precise current for a high range of load reaching 10 kOhm. The developed circuit solves critical requirements in the development of a bioimpedance spectrometers by ensuring the safety and accuracy in a wide frequency range and a wide impedance range.:1 Introduction 2 Theoretical background 3 Howland current sources 4 Methodical design of Howland Current Sources 5 Experimental investigations 6 Conclusions and Outlook
25

Caractérisation des tissus biologiques mous par diffusion multiple de la lumière / Characterization of soft biological tissues by diffusing wave spectroscopy

Zerrari, Naoual 18 March 2014 (has links)
La diffusion multiple de la lumière(DWS) est une technique qui permet de sonder la dynamique interne de milieux opaques et concentrés à des fréquences élevées. Elle a été utilisée pour déterminer les propriétés viscoélastiques de ces milieux. Elle a l'avantage d'être non destructive, rapide et sensible. Ce travail a pour objectif l'étude des tissus biologiques mous par DWS. La première étape est la mise en place du dispositif expérimental. Afin d'évaluer les limites de la technique, des études successives ont été réalisées sur des matériaux de complexité croissante (une suspension, le lait et une mousse) tendant vers la complexité structurale des tissus biologiques. Pour la suspension et le lait, la théorie de DWS peut s'appliquer et permet de mesurer avec une bonne précision leur viscosité. Les limites de DWS pour évaluer la viscosité sont atteintes avec la mousse dont la structure complexe est proche de celle des tissus biologiques. Enfin, le cortex rénal, le parenchyme hépatique et le cerveau de porc ont été étudiés. La théorie appliquée pour les milieux précédents ne permet pas de remonter à leur viscosité. Mais la DWS a permis de suivre leur microstructure au cours de la déshydratation et de la dégénérescence. Pour tous ces milieux la répétabilité, la reproductibilité, la variabilité et l'effet des conditions expérimentales ont été évalués. La DWS pourrait être utilisée pour étudier l'effet de la température et de la congélation sur le spectre de DWS des tissus biologiques ou combinée à la rhéologie pour suivre l'évolution des spectres de DWS au cours d'un cisaillement / Diffusing Wave Spectroscopy (DWS) is a technique that allows to probe the internal dynamics of opaque media and concentrated at high frequencies. It has been used to determine the viscoelastic properties of these media. It has the advantage of being nondestructive, rapid and sensitive. This work aims to study soft biological materials by DWS. The first step is setting up of the experimental device. To evaluate the limits of the art, successive studies were conducted on materials of increasing complexity (a suspension, milk and a foam) tending to the structural complexity of biological tissues. Concerning the suspension and milk, two concentrated media, and mono-dispersed in which the particles are in Brownian motion, DWS allowed to measure with good precision their viscosity. The limits of DWS to evaluate the viscosity of the medium are achieved with the foam which the complex structure is similar to that of soft biological tissues. Finally, the renal cortex, the hepatic parenchyma and porcine brain were studied. The theory applied to previous media does not allow to calculate viscosity. But the DWS allowed us to follow their microstructure during dehydration and degeneration. For all these media, repeatability, reproducibility, variability and effect of experimental conditions were evaluated. The DWS could be used to study the effect of temperature and freezing on the DWS spectrum of biological tissues, or combined with rheology to monitor the evolution spectra DWS during shear
26

Ανάπτυξη συστημάτων με χρήση μη ιοντιζουσών ακτινοβολιών για διαγνωστικές εφαρμογές και ανίχνευση εγκεφαλικής δραστηριότητας

Ασημάκης, Νικόλαος 05 January 2011 (has links)
Καθώς η εξέλιξη της βιοϊατρικής επιστήμης και τεχνολογίας είναι συνεχής και ραγδαία, η έρευνα επικεντρώνεται τόσο στη βελτίωση των κλινικών τεχνικών όσο και στην ανάπτυξη νέων με κυριότερο σκοπό την ακριβέστερη και ασφαλέστερη διάγνωση και θεραπεία. Στην παρούσα διατριβή, μελετάται η χρήση δύο περιοχών του φάσματος, που ανήκουν στο πεδίο των μη ιοντιζουσών ακτινοβολιών, των μικροκυματικών και των ακουστικών συχνοτήτων, για διαγνωστικές λειτουργικές εφαρμογές εγκεφάλου. Παρόλο που η χρήση των υπερήχων έχει αξιοποιηθεί στην κλινική εφαρμογή, οι αναφορές για τη χρήση των ακουστικών κυμάτων στις βιοϊατρικές εφαρμογές είναι περιορισμένες στη διεθνή βιβλιογραφία. Στην παρούσα διδακτορική διατριβή μελετάται η ανάπτυξη ενός συστήματος για διαγνωστικές εφαρμογές εγκεφάλου στις ακουστικές συχνότητες. Στα δύο πρώτα κεφάλαια περιγράφονται οι βασικές αρχές που διέπουν την επιστήμη του ήχου (ακουστική) αλλά και οι φυσικές αρχές αλληλεπίδρασης των ακουστικών κυμάτων με τους βιολογικούς ιστούς (δημιουργία και εξέλιξη των φυσικών φαινομένων ανάκλασης, διάθλασης, μετάδοσης και απορρόφησης της ηχητικής δέσμης). Πιο συγκεκριμένα, μοντελοποιείται και μελετάται θεωρητικά το πρόβλημα της αλληλεπίδρασης των ακουστικών κυμάτων με τον ανθρώπινο εγκέφαλο ενώ τέλος παρουσιάζονται βασικές και σύγχρονες εφαρμογές ακουστικής στην ιατρική. Στο τρίτο κεφάλαιο παρατίθεται η θεωρητική ανάλυση και οι βασικές αρχές της προτεινόμενης μεθόδου για μέτρηση της εγκεφαλικής δραστηριότητας στις ακουστικές συχνότητες και πραγματοποιούνται προσομοιώσεις, με τη βοήθεια του λογισμικού MATLAB, παραθέτοντας τα αντίστοιχα αριθμητικά αποτελέσματα. Ολοκληρώνοντας το πρώτο μέρος της διατριβής, στο τέταρτο κεφάλαιο παρουσιάζεται η πρακτική υλοποίηση του προτεινόμενου συστήματος, περιλαμβάνοντας ανάλυση του πιεζοηλεκτρικού φαινομένου και των αντίστοιχων αισθητήρων, εκτενής μελέτη του κάθε τμήματός του καθώς και πειραματικές μετρήσεις με ομοιώματα. Τα μικροκύματα έχουν χρησιμοποιηθεί σε πλήθος διαγνωστικών και θεραπευτικών τεχνικών τόσο σε επίπεδο έρευνας όσο και στην κλινική πράξη. Στην παρούσα διατριβή πραγματοποιείται θεωρητική μελέτη και υλοποίηση πολυσυχνοτικών κυρτών προσαρμόσιμων μικροταινιακών τυπωμένων κεραιών και χρήση τους με σύστημα ευαίσθητου δέκτη μικροκυματικής ραδιομετρίας. Στο κεφάλαιο 5 περιγράφονται η βασική τεχνολογία και οι βασικές αρχές λειτουργίας της παθητικής μεθόδου διάγνωσης με μικροκύματα, της μικροκυματικής ραδιομετρίας ενώ στο κεφάλαιο 6 μοντελοποιούνται οι προτεινόμενες κυρτές κεραίες και μελετούνται με τη βοήθεια του ηλεκτρομαγνητικού προσομοιωτικού λογισμικού πακέτου HFSS που χρησιμοποιεί τη μέθοδο των πεπερασμένων στοιχείων. Επίσης, παρουσιάζονται αναλυτικά οι ιδιότητες εστίασης των κεραιών αυτών σε δύο διαφορετικά μοντέλα κεφαλιού στο εύρος συχνοτήτων 2 – 3.3 GHz. Τέλος, οι κεραίες που μελετήθηκαν θεωρητικά, κατασκευάζονται και χρησιμοποιούνται ως κεραίες λήψης ραδιομέτρου τύπου διακόπτη Dicke (Dicke switch) για πειραματικές μετρήσεις σε ομοιώματα (κεφάλαιο 7). Ο συνδυασμός των δύο συστημάτων σε μια κοινή υλοποίηση και η πραγματοποίηση κοινών πειραματικών μετρήσεων και στις δύο περιοχές συχνοτήτων είναι μια πολύ σημαντική προοπτική που μπορεί να βελτιώσει τα πιθανά μειονεκτήματα της κάθε μεθόδου αλλά και να τις επαληθεύσει, με την παροχή και το συνδυασμό διαφορετικού είδους πληροφορίας για το ίδιο αίτιο. / As progress in the field of biomedical science and technology is continuous, the research focuses mainly on the improvement of existing clinical techniques and the development of new ones, aiming at the most accurate and safe diagnosis and treatment. In the present thesis, passive diagnosis in the non ionizing radiation regime and especially two frequency bands, microwave and acoustic frequencies, are used for diagnostic functional brain applications. Despite the fact that ultrasounds have been utilized in clinical practice, the references regarding the application of acoustic waves in medical diagnosis are restrained in international literature. In the present thesis the development of a system for diagnostic brain applications operating at acoustic frequencies is studied. In the first two chapters the basic principles of acoustics and the physical principles of the interaction of acoustic waves with biological tissue (including physical phenomena of reflection, diffraction, transmission and absorption of sound) are described. More specifically, the problem of the interaction of acoustic waves with the human brain tissues is theoretically modeled and studied. In the third chapter theoretical analysis is carried out and the basic operation principles of the suggested method for monitoring brain activity in acoustic frequencies are described. Simulations are performed using the MATLAB software and the respective numerical results are presented. Completing the first part of the thesis, the fundamentals of the system’s practical implementation are introduced in the fourth chapter. All system modules are described and the results of the implementation study through experiments using phantoms are presented. Microwaves have been used in many diagnostic and therapeutic techniques both at research level and in clinical practice. Herein, a theoretical study and implementation of various multi-frequency conformal microstrip patch antennas are performed, and finally they are used in conjunction with a sensitive microwave radiometry receiver. In chapter 5 the basic technology and the basic operation principles of the passive diagnostic method with microwaves (microwave radiometry) are described, while in chapter 6 the suggested conformal antennas are modeled and studied using the electromagnetic simulation tool HFSS that implements the finite element method (FEM). Moreover, the properties of these antennas and their focusing ability on specific brain areas are presented at 2 – 3.3 GHz in two different head models. Finally, a few are materialized in Rogers 4350B dielectric substrate and two of them are used together with a Dicke switch type radiometer for experimental measurements with phantoms (chapter 7). The combination of the aforementioned systems in a common implementation and the realization of common experimental measurements in both frequency bands is a very significant prospective which can optimize the performance of each methodology, by collecting and combining different types of information originating from the same event.
27

Simulation of Biological Tissue using Mass-Spring-Damper Models / Simulering av biologisk vävnad med hjälp av mass-spring-damper-modeller

Eriksson, Emil January 2013 (has links)
The goal of this project was to evaluate the viability of a mass-spring-damper based model for modeling of biological tissue. A method for automatically generating such a model from data taken from 3D medical imaging equipment including both the generation of point masses and an algorithm for generating the spring-damper links between these points is presented. Furthermore, an implementation of a simulation of this model running in real-time by utilizing the parallel computational power of modern GPU hardware through OpenCL is described. This implementation uses the fourth order Runge-Kutta method to improve stability over similar implementations. The difficulty of maintaining stability while still providing rigidness to the simulated tissue is thoroughly discussed. Several observations on the influence of the structure of the model on the consistency of the simulated tissue are also presented. This implementation also includes two manipulation tools, a move tool and a cut tool for interaction with the simulation. From the results, it is clear that the mass-springdamper model is a viable model that is possible to simulate in real-time on modern but commoditized hardware. With further development, this can be of great benefit to areas such as medical visualization and surgical simulation. / Målet med detta projekt var att utvärdera huruvida en modell baserad på massa-fjäderdämpare är meningsfull för att modellera biologisk vävnad. En metod för att automatiskt generera en sådan modell utifrån data tagen från medicinsk 3D-skanningsutrustning presenteras. Denna metod inkluderar både generering av punktmassor samt en algoritm för generering av länkar mellan dessa. Vidare beskrivs en implementation av en simulering av denna modell som körs i realtid genom att utnyttja den parallella beräkningskraften hos modern GPU-hårdvara via OpenCL. Denna implementation använder sig av fjärde ordningens Runge-Kutta-metod för förbättrad stabilitet jämfört med liknande implementationer. Svårigheten att bibehålla stabiliteten samtidigt som den simulerade vävnaden ges tillräcklig styvhet diskuteras genomgående. Flera observationer om modellstrukturens inverkan på den simulerade vävnadens konsistens presenteras också. Denna implementation inkluderar två manipuleringsverktyg, ett flytta-verktyg och ett skärverktyg för att interagera med simuleringen. Resultaten visar tydligt att en modell baserad på massa-fjäder-dämpare är en rimlig modell som är möjlig att simulera i realtid på modern men lättillgänglig hårdvara. Med vidareutveckling kan detta bli betydelsefullt för områden så som medicinsk bildvetenskap och kirurgisk simulering.
28

Untersuchung der Eignung von Methoden zur Schlingenverschleißanalyse bei der transurethralen Resektion der Prostata

Morgenstern, Tino 21 April 2022 (has links)
Die transurethrale Resektion der Prostata (TURP) ist eine elektrochirurgische Behandlung der gutartigen Vergrößerung der Prostata. Hierbei treten sehr selten gebrochene Resektionsschlingen auf, deren Ursachen in der Literatur unzureichend dokumentiert sind. In dieser Arbeit erfolgt die Untersuchung der Eignung von Methoden zur Schlingenverschleißanalyse bei der TURP. Es gilt die aktuell offenen Fragen zu klären, wie sich zum Beispiel der Schlingenverschleiß äußert, ob dieser Ursache für gebrochene Schlingen während einer Operation ist und ob er Einfluss auf den Leistungseintrag ins Prostatagewebe und damit auf Ihre Temperaturverteilung hat. Angewandt werden erstmals vier experimentelle Methoden zur Verschleißanalyse in Kombination. Gemessene Geometrieänderungen stehen in Zusammenhang mit einer gemessenen verschleißbedingten Impedanzänderung, welche hier erstmals in‑situ erfolgt. Diese liefert auch Informationen über Defekte im nichtsichtbaren Bereichen der Resektionsschlingen. Es geht auch hervor, dass aufgrund üblicher Nutzungsdauern der Schlingenverschleiß als Ursache für Schlingenbrüche während der Dauer einer Operation mit sehr großer Wahrscheinlichkeit auszuschließen ist. Aufbauend auf den Messergebnissen werden durch Finite Elemente Simulationen Informationen über den Leistungseintrag ins Prostatagewebe gewonnen. Die Auswertung der simulierten räumlichen Temperaturverteilung zeigt keine Vergrößerung von betroffenen Gewebearealen mit verschleißbedingtem Temperaturanstieg.:1 Einleitung 2 Grundlagen und Stand der Forschung 3 Lösungsansatz und Methoden 4 Versuchsumgebungen zur experimentellen Umsetzung 5 Ergebnisse der experimentellen Untersuchungen 6 Numerische Methoden 7 Ergebnisse aus den numerischen Methoden 8 Diskussion 9 Zusammenfassung / The transurethral resection of the prostate (TURP) is an electrosurgical treatment of benign prostatic hyperplasia. In the literature, broken resection loops are rarely discussed and the reasons for their occurrence are insufficiently documented. The purpose of the present work is to investigate the suitability of methods for loop wear analysis in TURP. The aim is to clarify the currently open questions such as: Does material wear on the loop surface lead to broken resection loops during the surgery procedure? How does material wear influence the power input into the prostate tissue and thus the resulting temperature distribution in the tissue? For the first time, four experimental methods for loop wear analysis are applied in combination. As a result, the experimental investigation show that it was possible to measure a wear-related impedance change in-situ, matching to the wear-related geometry change of the resection loop. Moreover, the measured impedance led to information about loop defects in an invisible part of the resection electrode. For the duration of the surgery procedure, the loop wear can be ruled out as the cause of broken loops with a very high probability. Finite element analyses were used for evaluating the spatial temperature distribution of the prostate tissue. The simulation model based on the measurement results. The simulated spatial temperature distribution does not show any enlargement of affected tissue areas due to wear-induced temperature increase.:1 Einleitung 2 Grundlagen und Stand der Forschung 3 Lösungsansatz und Methoden 4 Versuchsumgebungen zur experimentellen Umsetzung 5 Ergebnisse der experimentellen Untersuchungen 6 Numerische Methoden 7 Ergebnisse aus den numerischen Methoden 8 Diskussion 9 Zusammenfassung
29

Semi-quantitative röntgentomographische Untersuchungen zur Biodistribution von magnetischen Nanopartikeln in biologischem Gewebe

Rahn, Helene 13 February 2012 (has links) (PDF)
Im Rahmen der vorliegenden Dissertationsschrift „Semi-quantitative röntgentomographische Untersuchungen zur Biodistribution von magnetischen Nanopartikeln in biologischem Gewebe“ wurden tomographische Untersuchungen an biologischen Objekten durchgeführt. Bei diesen Objekten handelt es sich um Gewebeproben nach minimal-invasiven Krebstherapien wie zum Beispiel magnetischem Drug Targeting und magnetischer Wärmebehandlung. Der Erfolg dieser Therapien ist sowohl abhängig von der korrekten Verteilung der magnetischen Nanopartikel als auch von der Tatsache, dass diese in der Zielregion in einer ausreichenden Menge vorhanden sind. Das Vorliegen dieser beiden Voraussetzungen ist in der vorliegenden Arbeit untersucht worden. Dabei lag der Schwerpunkt der Arbeit auf der Quantifizierung von magnetischem Material in unterschiedlichen biologischen Gewebeproben mittels Röntgenmikrocomputertomographie (XµCT). Für diesen Zweck wurde ein Kalibrationssystem mit speziellen Phantomen entwickelt, mit dessen Hilfe eine Nanopartikelkonzentration einem Grauwert voxelweise zugewiesen werden kann. Mit Hilfe der Kalibration kann der Nanopartikelgehalt sowohl in monochromatischen als auch in polychromatischen tomographischen Daten im Vergleich zu magnetorelaxometrischen Ergebnissen mit wenigen Prozent Abweichung ermittelt werden. Trotz Polychromasie und damit einhergehenden Artefakten können 3-dimensionale röntgentomographische Datensätze mit einer geringfügigen Konzentrationsabweichung im Vergleich zur quantitativen Messmethode Magnetorelaxometrie semi-quantitativ ausgewertet werden. / The success of the minimal invasive cancer therapies, called magnetic drug targeting and magnetic heating treatment, depends strongly on the correct distribution of the magnetic nanoparticles on one side. On the other side it depends on the fact that a sufficient amount of magnetic nanoparticles carrying drugs is accumulated in the target region. To study whether these two requirements are fulfilled motivates this PhD thesis „Semi-quantitative X-ray-tomography examinations of biodistribution of magnetic nanoparticles in biological tissues“. The analysis of the distribution of the magnetic nanoparticles in tumours and other tissue examples is realized by means of X-ray-micro computer tomography (XμCT). The work focuses on the quantification of the magnetic nanoparticles in different biological tissue samples by means of XµCT. A calibration of the tomographic devices with adequate phantoms, developed in the frame of this work, opens now the possibility to analyze tomographic data in a semi-quantitative manner. Thus, the nanoparticle concentration can be allocated voxel-wise to the grey values of the three-dimensional tomographic data. With the help of calibration of the tomography equipments used, polychromatic as well as monochromatic three-dimensional representations of objects can be analyzed with regard to the biodistribution of magnetic nanoparticles as well as with regard to their quantity. The semi-quantitative results have been compared with results obtained with a quantitative measurement method magnetorelaxometry (MRX). Thereby a good agreement of the semi-quantitative and quantitative data has been figured out.
30

Semi-quantitative röntgentomographische Untersuchungen zur Biodistribution von magnetischen Nanopartikeln in biologischem Gewebe

Rahn, Helene 12 December 2011 (has links)
Im Rahmen der vorliegenden Dissertationsschrift „Semi-quantitative röntgentomographische Untersuchungen zur Biodistribution von magnetischen Nanopartikeln in biologischem Gewebe“ wurden tomographische Untersuchungen an biologischen Objekten durchgeführt. Bei diesen Objekten handelt es sich um Gewebeproben nach minimal-invasiven Krebstherapien wie zum Beispiel magnetischem Drug Targeting und magnetischer Wärmebehandlung. Der Erfolg dieser Therapien ist sowohl abhängig von der korrekten Verteilung der magnetischen Nanopartikel als auch von der Tatsache, dass diese in der Zielregion in einer ausreichenden Menge vorhanden sind. Das Vorliegen dieser beiden Voraussetzungen ist in der vorliegenden Arbeit untersucht worden. Dabei lag der Schwerpunkt der Arbeit auf der Quantifizierung von magnetischem Material in unterschiedlichen biologischen Gewebeproben mittels Röntgenmikrocomputertomographie (XµCT). Für diesen Zweck wurde ein Kalibrationssystem mit speziellen Phantomen entwickelt, mit dessen Hilfe eine Nanopartikelkonzentration einem Grauwert voxelweise zugewiesen werden kann. Mit Hilfe der Kalibration kann der Nanopartikelgehalt sowohl in monochromatischen als auch in polychromatischen tomographischen Daten im Vergleich zu magnetorelaxometrischen Ergebnissen mit wenigen Prozent Abweichung ermittelt werden. Trotz Polychromasie und damit einhergehenden Artefakten können 3-dimensionale röntgentomographische Datensätze mit einer geringfügigen Konzentrationsabweichung im Vergleich zur quantitativen Messmethode Magnetorelaxometrie semi-quantitativ ausgewertet werden. / The success of the minimal invasive cancer therapies, called magnetic drug targeting and magnetic heating treatment, depends strongly on the correct distribution of the magnetic nanoparticles on one side. On the other side it depends on the fact that a sufficient amount of magnetic nanoparticles carrying drugs is accumulated in the target region. To study whether these two requirements are fulfilled motivates this PhD thesis „Semi-quantitative X-ray-tomography examinations of biodistribution of magnetic nanoparticles in biological tissues“. The analysis of the distribution of the magnetic nanoparticles in tumours and other tissue examples is realized by means of X-ray-micro computer tomography (XμCT). The work focuses on the quantification of the magnetic nanoparticles in different biological tissue samples by means of XµCT. A calibration of the tomographic devices with adequate phantoms, developed in the frame of this work, opens now the possibility to analyze tomographic data in a semi-quantitative manner. Thus, the nanoparticle concentration can be allocated voxel-wise to the grey values of the three-dimensional tomographic data. With the help of calibration of the tomography equipments used, polychromatic as well as monochromatic three-dimensional representations of objects can be analyzed with regard to the biodistribution of magnetic nanoparticles as well as with regard to their quantity. The semi-quantitative results have been compared with results obtained with a quantitative measurement method magnetorelaxometry (MRX). Thereby a good agreement of the semi-quantitative and quantitative data has been figured out.

Page generated in 0.0927 seconds