21 |
Síntese de 2-(1,4,5,6-tetraidropiridin-3-il)-2-oxoacetato de etila 1,6-dissubstituídas via mecanismo ANRORC / ANRORC syntesis of 1,6-disubstituted ethyl 2-(1,4,5,6-tetrahydropyridin-3-yl)-2-oxoacetatePretto, Leida de Mendonça 18 March 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This paper presents a synthetic strategy for the preparation of two series of novel 1,6-disubstituted Ethyl 2-(1,4,5,6-tetrahydropyridin-3-yl)-2-oxoacetate from the reaction of the cyclic enone ethyl 2-(6-ethoxy-5 ,6-dihydro-4H-pyran-3-yl)-2-oxoacetate and aryl amines as precursors, following an ANRORC type mechanism. The substituents of the amines are the flowing: C6H5, C6H4-4-Cl, 3-Cl-C6H4,-C6H3 3,4-Cl 2,4-Cl-C6H3 3-F-C6H4, 2-F-C6H4 3-Me-C6H4, 2-OMe-C6H4, 4-Br-C6H4. The ethyl 1-aryl-6-arylamino-2-(1,4,5,6-tetrahydropyridin-3-yl)-2-oxoacetate were synthesized in a simple procedure, using room temperature and 24 h as the reaction condition. The products from this series were obtained with satisfactory yields between 45-93% and the purification thereof was performed by recrystallization.
To obtain the Ethyl 1-amino-6-ethoxy-2-(1,4,5,6-tetrahydropyridin-3-yl)-2-oxoacetate the ethyl 2-(1,4,5,6-tetrahydropyridin-3-yl)-2-oxoacetate was reacted withan equivalent of primary amine in ethanol and an equivalent of pyridine was required. The reaction was refluxed for 48h. Purification of this series of compounds was accomplished by eluting the compound through a chromatographic column. The products were obtained in good yields ranging from 66-86%. / Este trabalho apresenta uma estratégia sintética para a preparação de duas séries inéditas de 2-(1,4,5,6-tetraidropiridin-3-il)-2-oxoacetato de etila 1,6-dissubstituídas à partir da enona cíclica 2-(6-etóxi-5,6-diidro-4H-piran-3-il)-2-oxoacetato de etila e aril aminas como precursores, através de um único passo reacional. Essas aminas possuem diferentes substituintes, sendo eles: C6H5, 4-Cl-C6H4, 3-Cl-C6H4, 3,4-Cl-C6H3, 2,4-Cl-C6H3, 3-F-C6H4, 2-F-C6H4, 3-Me-C6H4, 2-OMe-C6H4, 4-Br-C6H4. As 1-aril-6-arilamino-2-(1,4,5,6-tetraidropiridin-3-il)-2-oxoacetato de etila, foram sintetizadas de maneira simples, utilizando temperatura ambiente e 24h como condição reacional. Os produtos dessa série foram obtidos com rendimentos satisfatórios, entre 45-93% e a purificação dos mesmos foi feita através de recristalização.
Para obtenção das 1-aril-6-etóxi-2-(1,4,5,6-tetraidropiridin-3-il)-2-oxoacetato de etila, foi necessário o uso equimolar de piridina como reagente no decorrer de todo o processo reacional, contando ainda com temperatura de refluxo e um período de 48h. A purificação dos compostos desta série foi efetuada de forma eficiente, sendo realizada através da eluição dos compostos através de uma coluna cromatográfica. Os produtos foram obtidos com bons rendimentos, variando entre 66-86%.
Todos os produtos sintetizados neste trabalho foram obtidos com alto grau de pureza e identificados por Ressonância Magnética Nuclear de Hidrogênio, Ressonância Magnética Nuclear de Carbono-13, Espectrometria de Massa, Análise elementar e Massa de alta resolução.
|
22 |
Resistência à fadiga flexural dos sistemas rotatórios k3 e Endosequence em razão do uso / Resistance to flexural fatigue of K3 and Endosequence rotary systems in relation to the useLuis Cesar Brisighello 30 October 2008 (has links)
O presente estudo teve como objetivo avaliar a resistência à fadiga cíclica de dois diferentes sistemas rotatórios de níquel-titânio, K3 (Sybron Endo, EUA) e Endosequence (Brasseler, EUA), fundamentando-se no número de usos. Todas as limas rotatórias que foram selecionadas possuíam conicidade 0.04, 25 mm de comprimento e diâmetro de ponta 25, padrão ISO. Para tal logro, um dispositivo desenvolvido especificamente para executar ensaios dinâmicos foi utilizado. Cada grupo foi subdividido em quatro subgrupos em função do número de usos, sendo estabelecidos da seguinte maneira: grupos A0 e B0, instrumentos sem nenhum uso; grupos A1 e B1, instrumentos de um único uso; grupos A3 e B3, instrumentos de três usos e grupos A5 e B5, instrumentos de cinco usos. Cada subgrupo era composto por 12 limas, totalizando 96 instrumentos rotatórios entre K3 e Endosequence. A simulação foi realizada em canais artificiais de resina com curvatura de 40 graus e raio de 5 mm. Todas as limas foram submetidas a ensaios de fadiga cíclica realizados em um dispositivo experimental que permitiu que o instrumento reproduzisse uma instrumentação rotatória em canais curvos. Esse dispositivo possui um temporizador, que registra o tempo de avanços em segundos, desde o início do movimento até a fratura da lima e também um contador, que registra dentro do intervalo de tempo o número de ciclos realizados pelo cilindro pneumático até o momento da fratura. Foi utilizada uma peça de mão com contra-ângulo redutor de 16:1, acionado por motor elétrico na velocidade de 350 rpm e 2 Ncm de torque. O tempo foi registrado por meio do contador presente no dispositivo. Os valores foram transformados em segundos. Para análise estatística, empregou-se o teste de análise de variância (dois critérios) entre as amostras testadas e observou-se que não houve diferença estatisticamente significante em relação ao número de usos. Entretanto, o sistema K3 apresentou maior resistência à fadiga flexural em relação ao sistema Endosequence (p < 0,05). / The aim of this work was to evaluate the cyclic fatigue resistance of two different nickel-titanium rotary systems, K3 (Sybron Endo, EUA) and Endosequence (Brasseler, EUA), based on the number of uses. All rotary files which were selected had their conicity of 0,04, 25mm of length and tip diameter of 25, following ISO standardization. To reach the purposes, a specially developed apparatus to perform dynamic assays was employed. Each group was subdivided into 4 subgroups according to the number of uses, being established as follows: groups A0 and B0, instruments without any use; groups A1 and B1, instruments of a single use; groups A3 and B3, instruments of three uses and groups A5 and B5, instruments of five uses. Each subgroup was compound of 12 files, totalizing 96 rotary instruments between K3 and Endosequence. The simulation was conducted in resin artificial canals presenting curvature of 40 degrees and radius of 5 mm. All files were submitted to cyclic fatigue assays performed on an experimental apparatus where the instrument could reproduce a rotary instrumentation in curved canals. This equipment contains an timer, which records advance time per seconds, since the begin of movement until the file fracture, and also has a counter which registers, on a period of time, the cycle number accomplished by the pneumatic cylinder until the fracture time. A reducer contra-angle hand piece of 16:1 was used, activated by an electric motor on a speed of 350rpm and 2 Ncm of torque. Time was recorded by the counter coupled in the apparatus. Values were converted into seconds. The two-way analysis of variance was employed to statistical evaluation, among tested samples and we could observe that no statistical differences were found in relation to the number of uses. However, the K3 system showed higher resistance to flexural fatigue when compared to the Endosequence system (p < 0,01).
|
23 |
Estudo da técnica de voltametria adsortiva de redissolução anódica, empregando o eletrodo DDB para detecção de metaisFerreira, Robson Dantas 28 January 2016 (has links)
Submitted by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-05-04T18:05:02Z
No. of bitstreams: 1
Dissertação - Robson Dantas Ferreira.pdf: 2998812 bytes, checksum: c551f20b9cce8eee052bd58fe5cf262d (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-05-04T18:05:41Z (GMT) No. of bitstreams: 1
Dissertação - Robson Dantas Ferreira.pdf: 2998812 bytes, checksum: c551f20b9cce8eee052bd58fe5cf262d (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-05-04T18:06:29Z (GMT) No. of bitstreams: 1
Dissertação - Robson Dantas Ferreira.pdf: 2998812 bytes, checksum: c551f20b9cce8eee052bd58fe5cf262d (MD5) / Made available in DSpace on 2016-05-04T18:06:29Z (GMT). No. of bitstreams: 1
Dissertação - Robson Dantas Ferreira.pdf: 2998812 bytes, checksum: c551f20b9cce8eee052bd58fe5cf262d (MD5)
Previous issue date: 2016-01-28 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The discharge of potentially toxic metals in water bodies has promoted significant changes in behavior harmful physical, chemical and biological receptor body. The detection of these contaminants with adequate selectivity, sensitivity, and reprodutibility is essential for reliable methods and required to determine these metal ions. The voltammetry of stripping are important electrochemical techniques in trace metals analysis. There is no study of the adsorptive anodic stripping voltammetry (AdASV) technical for in the current literature the determination of metal ions, using the Boron Doped Diamond Electrode (BDD). This study aimed to carry out a study on the determination of metals in aqueous medium using the BDD electrode with AdASV technique the supporting electrolyte selected was Britton - Robinson buffer 0,04 M, pH (1-11), and EDTA as chelating agent. For the Study of adsorptive process on the electrode surface DDB, voltammetric behavior of the complexes Fe-EDTA, Cu-EDTA and Zn-EDTA were analyzed and being possible to observe the oxidation processes related to Fe2+, Cu2+ and Zn2+, the methodology Technical AdASV was optimized by varying the following parameters: Deposition time (Td), deposition potential (Ed), frequency (f) and amplitude (a). Calibration curves were prepared for certain metals and found values for the detection limits LD and limits of quantification LQ. As LD: 0,005 ppm for Fe2+, Cu2+ 0,002 ppm and 0,02 ppm for Zn2+. LQ: 0,019 ppm for Fe2+, Cu2+ to 0,007 and 0,07 to Zn2+. After optimization of technical parameters, triplicate tests were carried out with real samples of the stream of forty in Manaus-AM, Brazil, the concentrations found through the methodology proposed for certain metals were: 0,09 ppm for Fe2+, 0,24 ppm Cu2+ and 0,06 ppm Zn2+. The results obtained with the optimization of the parameters of the voltammetric technique and detection in real sample showed that it is possible to use the BDD electrode for detecting metals in aqueous solution by the technique AdASV / A descarga de metais potencialmente tóxicos em corpos aquáticos tem promovido alterações prejudiciais significativas nos comportamentos físicos, químicos e biológicos do corpo receptor. A detecção destes contaminantes com seletividade adequada, sensibilidade e reprodutibilidade é essencial para que sejam impostas metodologias confiáveis na determinação desses íons metálicos. As voltametrias de redissoluções são técnicas eletroquímicas importantes na análise de metais-traço. Não há na literatura trabalhos que realizem um estudo da Técnica Voltametria Adsortiva de Redissolução Anódica (AdASV) na determinação de íons metálicos, empregando o Eletrodo de Diamante Dopado com Boro (DDB). Este trabalho teve como objetivo realizar um estudo acerca da determinação de metais em meio aquoso utilizando o eletrodo DDB com a técnica AdASV. Foi selecionado como eletrólito suporte o Tampão Britton – Robinson 0,04M, pH (1-11), e o EDTA como agente quelante. Para o Estudo do processo adsortivo na Superfície do Eletrodo DDB, foram analisados os comportamentos voltamétricos dos seguintes complexos: Fe-EDTA, Cu-EDTA e Zn-EDTA, sendo possível observar processos de oxidação referentes aos íons Fe2+, Cu2+ e Zn2+, a metodologia da Técnica AdASV foi otimizada variando os seguintes parâmetros: Tempo de Deposição (Td), Potencial de Deposição (Ed), Frequência (f) e amplitude (a). Foram elaboradas curvas analíticas para os determinados metais e encontrados valores referentes aos Limites de detecção LD e Limites de Quantificação LQ. Sendo LD: 0,005 ppm para o Fe2+, 0,002 ppm para Cu2+ e 0,02 ppm para o Zn2+. LQ: 0,019 ppm para o Fe2+, 0,007 para o Cu2+ e 0,07 para o Zn2+. Após a otimização dos parâmetros da técnica, foram realizados ensaios triplicatas com amostras reais coletadas do igarapé do quarenta em Manaus-AM-Brasil, as concentrações encontradas através da metodologia proposta para os determinados metais foram: 0,09 ppm para Fe2+, 0,24 ppm Cu2+ e 0,06 ppm para Zn2+. Os Resultados obtidos com a otimização dos parâmetros voltamétricos da Técnica e a detecção em amostra real demonstraram que é possível utilizar o Eletrodo DDB para detecção de metais em solução aquosa através da Técnica AdASV
|
24 |
Oxidação eletroquímica do etanol em eletrólito alcalino utilizando nanocompósito a base de grafeno/paládio / Electrochemical oxidation of ethanol in alkaline electrolyte using graphene / palladium base nanocompositeFerreira Sobrinho, Luiza 13 December 2018 (has links)
Nesse estudo foi sintetizado e caracterizado o óxido de grafeno (OG) a partir do método de Hummers modificado. O OG foi utilizado como suporte para nanopartículas de paládio para uso como eletrocatalisador em células a combustíveis abastecidas diretamente a etanol. O uso de carbono grafite como suporte de nanopartículas metálicas é deteriorado com mais rapidez, levando a diminuição do tempo de vida útil da célula a combustível. O objetivo principal foi a incorporação do paládio no óxido de grafeno via feixe de elétrons, e a comparação com o catalisador incorporado por via química, utilizando o borohidrato de sódio. Foram utilizadas técnicas de caracterização tais como: termogravimetria (TG), difração de raios-X (DRX), as espectroscopias de Raman e infravermelho com transformada de Fourier (FT-IR), microscopia de transmissão eletrônica (MET), Espectroscopia de fotoelétrons por raios- X (XPS) e estudos voltamétricos como a voltametria cíclica e cronoamperometria. Os resultados indicaram que para a dose de 288 kGy, houve a incorporação, porém, não foi suficiente para que houvesse a redução dos grupos oxigenados, estudos com o oxido de grafeno previamente reduzido via térmica e incorporado via feixe de elétrons foram comparados na mesma dose. / In this study, graphene oxide (GO) was synthesized by the modified Hummers method and characterized. GO was used as support for palladium nanoparticles as an electrocatalyst on direct ethanol fuel cell (DEFC). One of the drawbacks using carbon graphite as a support for metal nanoparticles was because it deteriorates more quickly, leading to shortened fuel cell life. The main objective was the incorporation of Pd on the graphene oxide by the electron beam and was compared with the chemical incorporation, using sodium borohydride. Characterization techniques such as thermogravimetry (TG), X-ray diffraction (XRD), Raman spectroscopy and Fourier transform infrared (FT-IR), electron transmission microscopy (TEM), X-ray photoelectron spectroscopy (XPS) and voltammetric studies such as cyclic voltammetry and chronoamperometry. The results indicated that at a dose of 288 kGy, there was an incorporation, however, it was not enough for there to be a decrease in the groups of oxygenates, studies with the graphene oxide downloaded through the thermal and through electron beams were compared in the same dose.
|
25 |
Fadiga cíclica flexural de instrumentos Hyflex CM e TF Adaptive em diferentes situações experimentais / Flexural cyclic fatigue of instruments Hyflex CM and TF Adaptive in diferente experimental situationsMustafá, Nágila Ali 08 March 2016 (has links)
O presente estudo teve como objetivo avaliar a resistência à fadiga cíclica flexural dos instrumentos de níquel- titânio, Hyflex CM (Coltène, EUA) e TF Adaptive (SybronEndo, EUA) em diferentes situações experimentais. Todas as limas que foram selecionadas possuíam conicidade 0,04 e diâmetro de ponta 35. Utilizou-se um dispositivo desenvolvido especificamente para realizar o ensaio flexural dinâmico. Os instrumentos TF Adaptive foram divididos em 3 grupos de acordo com o ângulo de curvatura do ensaio: 45º, 60º e 90º e cada grupo subdividido em 2 subgrupos de acordo com o tipo de movimento: rotação contínua e Adaptive. Cada subgrupo era composto por 15 instrumentos TF Adaptive, totalizando 90 instrumentos. Quinze instrumentos Hyflex CM formavam o grupo 4, no ensaio com ângulo de curvatura 90 graus e rotação contínua. A simulação foi realizada em canais artificiais de aço com ângulo de 45, 60, 90 graus e raio 5m m. O número de ciclos e o tempo em segundos até a fratura foram tabulados e analisados. Entretanto, a fadiga cíclica flexural foi significante maior nos três grupos em movimento Adaptive. E as limas TF Adaptive em seu próprio movimento tiveram maior número de ciclos e tempo até a fratura quando comparadas as Hyflex CM no ensaio de 90 graus. Portanto, conclui-se que o sistema Adaptive (limas TF Adaptive + movimento Adaptive) foi mais seguro à resistência á fadiga flexural, e no ensaio de 90 graus o sistema Adaptive foi mais resistente quando comparado com as limas Hyflex CM no movimento de rotação contínua. / The aim of this work to evaluate the cyclic fatigue resistance flexural the instruments of nickel-titanium, HyFlex CM (Coltène, USA) and TF Adaptive (SybronEndo, USA) in different experimental situations. All files that were selected had 0.04 taper and tip diameter 35. We used a device developed specifically to perform the dynamic flexural test. The TF Adaptive instruments were divided into 3 groups according to the angle of curvature of the test: 45, 60 and 90 and further divided in two subgroups according to the type of movement: continuous rotation and Adaptive. Each group consisted of 15 instruments TF Adaptive totaling 90 instruments. Fifteen HyFlex CM instruments formed the group 4 in the trial of bend angle 90 degrees and continuous rotation. The simulation was performed in artificial steel angled channels 45, 60, 90 degrees and radius 5m m. The number of cycles and the time in seconds until fracture were tabulated and analyzed. However, the cyclical flexural fatigue was significantly greater in the three groups Adaptive motion. And the TF Adaptive files on your own movement had a higher number of cycles and time to fracture when the HyFlex CM compared in 90-degree test. Therefore, it is concluded that the adaptive system (TF Adaptive Motion + Adaptive files) was safer resistance to flexural fatigue, and 90 degrees test Adaptive system is more resistant when compared with the HyFlex files into continuous.
|
26 |
Preparação e caracterização de carbono polimérico vítreo a partir da resina resol e modificação com íons metálicos / Preparation and Characterization of Glassy Polymeric Carbon from Resin Resol and Its Modification with Metallic IonsJesus, Celso Ricardo Nogueira 03 July 2009 (has links)
Pertencendo à família dos eletrodos de carbono, o carbono polimérico vítreo (CPV) apresenta condutividade elétrica, estabilidade térmica, resistência mecânica e grande intervalo de potencial. Dessa forma, se torna possível sua aplicação como eletrodo sólido para o monitoramento de processos de transferência de carga, suporte para polímeros eletroativos e modificadores de superfície. O processo de obtenção do CPV se baseia na carbonização em ambiente inerte de materiais precursores, dentre os quais, podem-se destacar as resinas fenólicas, como por exemplo, resol (C7H8O2). Neste contexto, este trabalho investiga a obtenção do CPV a partir da resina fenólica resol, bem como o efeito da incorporação de íons metálicos (crômio, ferro e cério) na estrutura cristalina e nas propriedades eletroquímicas. Os materiais foram caracterizados por análise térmica, microscopia eletrônica de varredura, difratometria de raio-X, espectrofotometria no infra-vermelho e por voltametria cíclica. O difratograma de raio-X confirmou a obtenção de um material com estrutura similar a do carbono vítreo e, através da microscopia eletrônica de varredura, ficou comprovada a baixa porosidade do CPV. Por espectrofotometria no infra-vermelho, ficou demonstrada a presença de grupos funcionais, como carbonilas e hidroxilas, na estrutura do material. Os resultados mostram que tanto o CPV quanto o CPV modificado por íons metálicos possuem boa estabilidade térmica, pois não houve nenhuma decomposição desses materiais abaixo de 400ºC. E, tanto o CPV quanto o CPV modificado por íons metálicos apresentam comportamento eletroquímico similar no sistema ferricianeto/ferrocianeto. Concluindo, o método desenvolvido para obtenção do CPV modificado por íons metálicos é satisfatório, reprodutivo além de proporcionar uma dispersão homogênea dos íons na fase do CPV. Desta forma, possibilita uma nova frente de estudos destes materiais eletródicos em eletrocatálise e eletroanalítica. / Belonging to the family of the carbon electrodes, the glassy polymeric carbon (GPC) presents electric conductivity, thermal stability, mechanical resistance mechanics and great potential interval. In this way, it is possible its application as solid electrode in order to follow electron transfer process, act as support of electroactive molecules and surface modifier. The glassy polymeric carbon production is based on carbonization of organic precursors in inert atmosphere such as phenolic resins (for example, resol - C7H8O2) In this context, this work investigates the production of GPC from phenolic resin, as well as the effect of incorporation of metallic ions (chromium, iron, and cerium) on crystalline structure and electrochemical properties. The materials were characterized by thermal analysis, scanning electron microscopy, X-ray diffraction, infrared spectrophotometry, and cyclic voltammetry. X-ray diffraction patterns had confirmed the presence of a material with similar structure of that found in conventional glassy carbon, and through SEM images it has shown a low porosity carbon material. From infrared spectrum, it can be observed carbonyl and hydroxide groups. The found results showed that both GPC and metallic ion modified GPC exhibit thermal stability, since no decomposition has occurred up to 450 oC. And, both carbon materials present similar electrochemical behavior in hexacyanoferrate system. In conclusion, the method developed for attainment of the GPC modified for ions metallic is satisfactory, and reproductive. Besides, it provides a homogeneous dispersion of ions in the bulk phase of the GPC. As a consequence, it makes possible a new front of studies of these materials in electrocatalysis and electroanalysis.
|
27 |
Estudo da eletrodeposição da liga Zn/Co sobre aço carbono e sua resistência à corrosão. / Study of the electrodeposition of Zn/Co alloy on carbon steel and its corrosion resistance.Falcón Roque, Jesús Marino 08 March 2010 (has links)
Este trabalho consiste no estudo da eletrodeposição de ligas de Zn/Co para diferentes relações de concentração [Zn2+]/[Co2+] (1:1, 3:1, 6:1, 9:1 e 12:1) sobre aço-carbono ABNT 1020 e sua resistência à corrosão, usando como banho um eletrólito à base de cloretos. Foram realizados estudos preliminares sobre o mecanismo de deposição da liga Zn/Co usando a técnica de voltametria cíclica e estabeleceram-se assim os parâmetros de deposição da liga. Os ensaios de deposição para as relações de concentração [Zn2+]/[Co2+] : 9/1 e [Zn2+]/[Co2+] : 12/1 no banho foram realizados usando a técnica potenciostática (cronoamperometria) e a técnica galvanostática (cronopotenciometria). As relações 1:1, 3:1 e 6:1 não foram escolhidas já que os teores de cobalto de seus eletrodepósitos não estavam na faixa de 1 % a 2 %. Foram feitas análises por microscopia eletrônica de varredura (MEV) para conhecer a diversidade morfologia dos eletrodepósitos como conseqüência do aumento do conteúdo de íons de zinco no banho. A identificação das fases dos eletrodepósitos foi feita por difração de raios X (XRD) e a composição elementar mediante espectroscopia de energia dispersiva de raios X (EDS) e fluorescência de raios X (XRF). Os ensaios de avaliação da resistência à corrosão foram realizados em solução naturalmente areada de NaCl 0,1 M por técnicas eletroquímicas como espectroscopia de impedância eletroquímica e curvas de polarização potenciodinâmicas. A partir dos resultados obtidos na voltametria cíclica foi possível selecionar a faixa de potencial adequada para a realização dos ensaios potenciostáticos e galvanostáticos das relações [Zn2+]/[Co2+] 9:1 e 12:1. As análises dos dados obtidos dos transientes de corrente (ensaios potenciostáticos) para cada relação (9:1 e 12:1) permitiram concluir que para ambas as relações seus processos de nucleação ocorrem seguindo uma transição, iniciando-se como progressiva para t/tmax < 1 e passando a instantânea para t/tmax > 1. As técnicas eletroquímicas usadas para avaliar a resistência à corrosão mostraram que os eletrodepósitos obtidos com a técnica potenciostática foram mais resistentes à corrosão que os eletrodepósitos obtidos com a técnica galvanostática, sendo o potencial de - 1450 mV vs Ag/AgCl e a densidade de corrente catódica de 30 mA/cm2 as melhores condições para a obtenção de eletrodepósitos de Zn/Co com boa resistência à corrosão. / This work reports the study of the electrodeposition of Zn/Co alloys with different concentration ratios [Zn2+]/[Co2+] (1:1, 3:1, 6:1, 9:1 e 12:1) on carbon steel ABNT 1020 and its corrosion resistance, using a chloride - based electrolyte. Initial studies were performed to find the best parameters of deposition by cyclic voltammetry. The alloy deposition for concentration ratios of [Zn2+]/[Co2+] : 9/1 and [Zn2+]/[Co2+] : 12/1 were carried out using potentiostatic (chronoamperometry) and galvanostatic (chronopotenciometry) techniques. The ratios 1:1, 3:1 e 6:1 were not chosen because them composition in cobalt were not within the range of 1% to 2%. Scan electron microscopy (SEM) was performed in order to verify the morphological diversity of the electrodeposits as a consequence of the increasing zinc concentration in the bath. X-ray diffraction was used to identify the phases present in the electrodeposits; their elemental composition was determined by X-ray dispersive energy spectroscopy and X-ray fluorescence. Corrosion resistance experiments were performed in aerated 0,1 M NaCl solution by electrochemical techniques such as electrochemical impedance spectroscopy and potenciodynamic polarization curves. From the voltametric results it was possible to select the adequate potential range in order to perform the potenciostatic and galvanostatic experiments for concentration ratios of [Zn2+]/[Co2+] 9:1 and 12:1. Analysis of the data obtained from the current transients for each ratio (9:1 and 12:1) allow us to conclude that, for both ratios, the processes of nucleation occur following a transition which starts as progressive for t/tmax < 1 and become instantaneous for t/tmax > 1. The electrodeposits obtained by potentiostatic and galvanostatic techniques were evaluated for their corrosion resistant and the best results were found for potentiostatic deposition at -1450 mV vs Ag/AgCl and galvanostatic deposition at 30 mA/cm2. In general, the deposits obtained potentiostatically showed better corrosion resistant.
|
28 |
"Uso de pirrolidinoditiocarbamatos de manganês(II) e vanadila na preparação e aplicação de eletrodos de pasta de carbono modificados"Segnini, Aline 26 June 2003 (has links)
Devido à sua baixa solubilidade em água, os pirrolidinoditiocarbamatos poderiam produzir eletrodos livres do problema de lixiviação do modificador, os quais poderiam ser usados como detectores amperométricos, em análises em fluxo e outros procedimentos hidrodinâmicos. O complexo poderia agir como um intermediário de transferência de elétrons entre o analito e a superfície eletródica, aumentando a sensibilidade da resposta analítica do sensor. Desta forma, eletrodos de pasta de carbono modificados (EPCM) com complexos de pirrolidinoditiocarbamatos anidros de diversos metais foram preparados e testados quanto à sua aplicação em técnicas voltamétricas. Os complexos de manganês(II), [MnPyr2] e cobalto(II), [CoPyr2], foram os que apresentaram os melhores resultados em termos de estabilidade e reprodutibilidade de resposta, escolhendo-se o EPCM-[MnPyr2], para uso neste trabalho. O desempenho do eletrodo foi avaliado usando voltametria cíclica, cronoamperometria e análise em fluxo, com detecção amperométrica de peróxido de hidrogênio apresentando regiões lineares de 1,25-14,8; 0,5-41; 1,0-75 x 10-4 mol L-1 e limites de detecção de 11,2; 2,98; 5,40 x 10-5 mol L-1 respectivamente para cada técnica. Na determinação de peróxido de hidrogênio em amostra de alvejante comercial observou-se concordância nos resultados obtidos em voltametria cíclica e análise em fluxo, usando o eletrodo proposto em comparação com a permanganometria clássica, com 95 % de intervalo de confiança. Estes resultados foram obtidos após otimização de parâmetros como velocidade de varredura, pH, eletrólito suporte, entre outros. A oxidação ocorre por meio de um processo eletrocatalítico. O desempenho do pirrolidinoditiocarbamato de vanadila hidratado também foi avaliado como alternativa aos ditiocarbamatos anidros, na preparação de eletrodos modificados com esta classe de complexos, considerando que os complexos hidratados seriam mais fáceis de preparar. Entretanto uma baixa estabilidade e reprodutibilidade de resposta foi observada. O [MnPyr2] mostrou comportamento no qual ocorre oxidação, concordando com a proposta de Schrauzer para ligantes do tipo ímpar, apesar de que a oxidação só ocorreu na presença de oxidantes fortes, como o peróxido de hidrogênio. / Considering their low solubility in water, the dithiocarbamate complexes should produce electrodes without problems of modifier leaching. Such electrodes could be used as amperometric detectors in flow injection analysis and hydrodynamic methods. The complex should act as an electron transfer mediator between the analyte and the electrode surface, improving the response sensitivity of the sensor. Considering these statements carbon paste electrodes modified (EPCM) with anhydrous pyrrolidinedithiocarbamates of several metals were prepared and evaluated in relation to their possible application in voltammetric techniques. Best results regarding response stability and reproducibility were obtained with manganese(II), [MnPyr2] and cobalt(II), [CoPyr2] complexes. The first one was chosen to develop the present work. The electrode performance was evaluated in cyclic voltammetry, chrono amperometric and flow injection analysis with amperometric detection. Linear dynamic ranges of 1,25-14,8; 0,5-41; 1,0-75 x 10-4 mol L-1 and limits of detection of 11,2; 2,98; 5,40 x 10-5 mol L-1 were found respectively for each technique in the determination of hydrogen peroxyde. The methods were used for the determination of H2O2 in bleaching formulation and presented agreement with the classical titration with potassium permanganate within 95% confidence level. Such results have been obtained after optimization of experimental parameters such as scan rate, pH, supporting electrolyte, and others. The oxidation occurred by an electrocatalytic process. Finally the performance of a carbon paste electrode modified with a hydrated vanadyl pyrrolidinedithiocarbamate complex was evaluated as an alternative to the anhydrous complex in the preparation of the modified electrode, since the hydrated complexes are easier to prepare. However a low response stability and reproducibility have been observed. The [MnPyr2] presented an oxidation behavior in agreement with Schrauzers predictions, although the oxidation of the metal center occurred only in the presence of strong oxidative agents as the hydrogen peroxide.
|
29 |
Comparison of mechanical behavior between conventional NiTi, CM, M-Wire and CM-EDM alloy instruments for cyclic fatigue and torsion fracture - evaluation of fracture surface in scanning electron microscope / Comparação do comportamento mecânico entre instrumentos de liga NiTi convencional, CM, M-Wire e CM-EDM quanto a fratura por fadiga cíclica e por torção avaliação da superfície da fratura em microscópio eletrônico de varreduraRenan Diego Furlan 31 July 2018 (has links)
The aim of this study was to evaluate the cyclic and torsional fatigue resistance of Nickel-Titanium rotary instruments manufactured by different thermal treatments. Were tested a total of 140 rotary instruments (n=20): Genius (GN size 25, .04 taper), Trushape (TS size 25, .06 taper), Logic (LOG size 25, .06 taper), Vortex Blue (VB size 25, .06 taper), ProTaper Gold (PTG size 25, .08 taper), Hyflex CM (HCM size 25, .06 taper) and Hyflex EDM (EDM size 25, .08 taper). Cyclic fatigue resistance testing was performed using an artificial stainless steel canal with a curvature (60° angle and 5- mm radius) located at 5 mm from the tip. The files (n=10) rotated until fracture and time was recorded in seconds. The torsional test evaluated the angular deflection and torque at failure of the instruments (n=10) at 3 mm from the tip according to ISO 3630- 1. The fractured surface of five instruments of each brand was observed by using scanning electron microscopy (SEM). Data were analysed using one-way ANOVA and Tukey tests, and the level of significance was set at 5%. The cyclic fatigue resistance value of EDM size 25, .08 taper was significantly higher than those of all instruments tested (P<0.05). The LOG size 25, .06 taper showed a higher cyclic fatigue resistance than those of GN size 25, .04 taper; TS size 25, .06 taper (P<0.05). There was no difference among the others groups. The torsional test showed that PTG size 25, .08 taper had the highest torsional strength value of all instruments tested followed by VB size 25, .06 taper and EDM size 25, .06 taper (P<0.05). The LOG size 25, .06 taper showed significant difference only with GN size 25, .04 taper (P<0.05). No difference was found among the others groups (P>0.05). In relation to angular deflection, the GN size 25, .04 taper; TS size 25, .06 taper; HCM size 25, .06 taper, and EDM size 25, .08 taper showed significantly higher values until fracture than the others groups (P<0.05). No difference was found among PTG size 25, .08 taper, LOG size 25, .06 taper, and VB size 25, .06 taper (P<0.05). The EDM size 25, .08 taper presented the highest cyclic fatigue resistance among all the tested instruments. For the torsional test, the PTG size 25, .08 taper showed highest torsional strength and lowest angular deflection values. / O objetivo deste estudo foi avaliar a resistência às fadigas cíclica e torsional de instrumentos rotatórios de Níquel - Titânio fabricados por diferentes tratamentos térmicos. Foram testados o total de 140 instrumentos (n=20): Genius (GN diâmetro 25, conicidade .04), Trushape (TS diâmetro 25, conicidade .06), Logic (LOG diâmetro 25, conicidade .06), Vortex Blue (VB diâmetro 25, conicidade .06), ProTaper Gold (PTG diâmetro 25, conicidade .08), Hyflex CM (HCM diâmetro 25, conicidade .06) e Hyflex EDM (EDM diâmetro 25, conicidade .08). O teste de resistência à fadiga cíclica foi realizado utilizando um canal artificial de aço inoxidável com curvatura (ângulo de 60° e raio de 5mm) localizada a 5 mm da ponta. Os instrumentos (n=10) foram rotacionados até a fratura e tempo foi registrado em segundos. O teste torsional avaliou a deflexão angular e torque até a falha dos instrumentos (n=10) a 3 mm da ponta de acordo com a ISO 3630-1. A superfície da fratura de 5 instrumentos de cada fabricante foi observado utilizando o microscópio eletrônico de varredura (MEV). A análise-estatística foi realizada utilizando o teste de análise de variância com um fator ANOVA e teste de Tukey, o nível de significância foi de 5%. O valor de resistência a fadiga cíclica do EDM diâmetro 25, conicidade .08 foi significantemente maior que todos os instrumentos testados (P<0.05). A LOG diâmetro 25, conicidade .06 mostrou maior resistência à fadiga cíclica que o GN diâmetro 25, conicidade .04; TS diâmetro 25, conicidade .06 (P<0.05). Não houve diferença significante entre os outros grupos. O teste torsional mostrou que PTG diâmetro 25, conicidade .08 obteve o maior valor de torque até a fratura de todos os instrumentos testados seguido por VB diâmetro 25, conicidade .06 e EDM diâmetro 25, conicidade .06 (P<0.05). O LOG diâmetro 25, conicidade .06 mostrou diferença significativa apenas com com GN diâmetro 25, conicidade .04 (P<0.05). Não houve diferença significativa entre os outros grupos (P>0.05). Em relação a deflexão angula, o GN diâmetro 25, conicidade .04; TS diâmetro 25, conicidade .06; HCM diâmetro 25, conicidade .06 e EDM diâmetro 25, conicidade .08 apresentou significantimente o maior valor até a fratura que os outros grupos (P<0.05). Nao foi encontrado diferença significativa entre PTG diâmetro 25, conicidade .08, LOG diâmetro 25, conicidade .06, e VB diâmetro 25, conicidade .06 (P<0.05). O EDM diâmetro 25, conicidade .08 apresentou a maior resistência a fadiga cíclica entre todos os instrumentos testados. Para o teste torsional, o PTG diâmetro 25, conicidade .08 apresentou o maior valor de torque e menor deflexão angular.
|
30 |
Avaliação da resistência à fadiga cíclica flexural dos instrumentos Reciproc Blue e WaveOne Gold / Evaluation of cyclic flexural fatigue of Reciproc Blue and WaveOne Gold instrumentsPoveda, Leonardo Medina 04 July 2017 (has links)
Inquestionavelmente, inovações ocorridas nos últimos anos no preparo do canal radicular revolucionaram o tratamento endodôntico. Dentre elas, destaca-se o tratamento térmico recristalizador da liga de níquel-titânio na confecção de limas endodônticas, o qual aumentou de sobremaneira sua flexibilidade e as capacidades de flexibilidade, torção e resistência à fadiga cíclica flexural quando comparadas às limas de níquel-titânio convencionais fabricadas até então. O presente estudo teve como objetivo avaliar a resistência à fadiga cíclica flexural dos instrumentos de níquel-titânio tratados termicamente Reciproc Blue R25 (VDW) e WaveOne Gold Primary (Dentsply-Maillefer) em um dispositivo desenvolvido especificamente para realizar ensaios flexurais dinâmicos. As limas selecionadas possuíam conicidade 0,08 mm e 0,07 mm respectivamente, com diâmetros de ponta 0,25 mm e foram utilizadas no motor elétrico VDW Silver Reciproc (VDW) em movimento reciprocante específico de cada sistema. Os instrumentos foram divididos em 2 grupos de 15 limas e testados em canais de aço simulados com o ângulo de 60º e raio de curvatura de 5mm. O número de ciclos e o tempo em segundos até a ocorrência de fratura dos instrumentos foram registrados e estatisticamente avaliados. As limas Reciproc Blue R25 apresentaram desempenho significativamente melhor (P<0,05), por meio do maior número de ciclos e de tempo até a fratura quando comparadas com as limas WaveOne Gold. Assim, conclui-se que o sistema Reciproc Blue R25 foi mais seguro quanto à resistência à fadiga flexural no ensaio realizado quando comparado ao sistema WaveOne Gold Primary em movimento reciprocante. / Innovations that have occurred in recent years in the preparation of the root canal have revolutionized endodontic treatment. Among them, the heat treatment of the nickel-titanium alloy in the manufacture of endodontic files, which greatly increased the flexibility, torsional and flexural fatigue resistance capacities when compared to the conventional nickel-titanium files manufactured until then. The present study aimed to evaluate the resistance to flexural cyclic fatigue of thermally treated Reciproc Blue R25 (VDW) and WaveOne Gold Primary (Dentsply-Maillefer) instruments in a device specifically developed to perform dynamic flexural tests. The selected files had taper 0.08 mm and 0.07 mm respectively, with tip diameters of 0.25 mm and were used in the reciprocating movement of each system in the VDW Silver Reciproc (VDW) electric motor. The instruments were divided into 2 groups of 15 files and tested in simulated steel channels with angle of 60º and radius of curvature of 5mm. The number of cycles and the time in seconds until the occurrence of fracture of the instruments were recorded and statistically evaluated. The Reciproc Blue R25 files presented significantly better performance (p <0.05), by the higher number of cycles and time to fracture when compared to WaveOne Gold files. Thus, it was concluded that the Reciproc Blue R25 system was safer than the WaveOne Gold Primary reciprocating system in terms of resistence of flexural fatigue
|
Page generated in 0.6293 seconds