421 |
Modelagem e monitoramento hidrológico das bacias hidrográficas dos córregos Botafogo e Cascavel, Goiânia – GO / Hydrological modeling and monitoring watershed streams Botafogo and Cascavel, Goiânia - GOPereira, Tatiane Souza Rodrigues 28 April 2015 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2015-10-23T11:41:58Z
No. of bitstreams: 2
Dissertação -Tatiane Souza Rodrigues Pereira - 2015.pdf: 12338914 bytes, checksum: c966794ae558bcc73711fb5a806a52dd (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2015-10-23T11:45:02Z (GMT) No. of bitstreams: 2
Dissertação -Tatiane Souza Rodrigues Pereira - 2015.pdf: 12338914 bytes, checksum: c966794ae558bcc73711fb5a806a52dd (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-10-23T11:45:02Z (GMT). No. of bitstreams: 2
Dissertação -Tatiane Souza Rodrigues Pereira - 2015.pdf: 12338914 bytes, checksum: c966794ae558bcc73711fb5a806a52dd (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Previous issue date: 2015-04-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Financiadora de Estudos e Projetos- Finep / The impermeabilization of Brazil watersheds have generated socio-economic and environmental impacts innumerable, which has resulton a dare for public administrations. This because most of the towns do not have an efficient drainage system, this causes the water seeps quickly into water streams that are not prepared to support this new level of streamflow, mainly towards the extreme rainfall events. Thus, the hydrological modeling appears like an important support tool for planning and management. However this tool is subject to limitations that must be ascertained through calibration and model validation in real field conditions. This calibration process has been the focus of research and discussion in the last 50 years, and the most currently accepted models are based on uncertainty those analysis to determine the parameters. This study aims at the assessthe development and calibration of the model rainfall-runoff UFGModel1.1 as well as analyze the uncertainty applied to the simulation of streamflow. For this purpose, we used methodologies of uncertainty analysis by means of the Monte Carlo methods (MC) and Markov Chain Monte Carlo (MCMC), which form the basis of the GLUE and DREAM algorithms, respectively, for estimating uncertainties.The results demonstrate that DREAM performs better than the calibrating the GLUE. The various sets of parameters found for both algorithms were considered great for model validation, enabling high efficiency of this precipitation events for medium at very strong with relatively narrow uncertainty limits for DREAM and great for GLUE. The parameter that showed lower sensitivity in the model was the Manning channel. / A impermeabilização das bacias hidrográficas brasileiras têm gerado inúmeros impactos sócio-econômicos-ambientais, o que tem resultado em um desafio para as gestõespúblicas. Isso porque, a maioria das cidades não possuem um sistema de drenagem eficiente, assim a água escoa rapidamente para dentro cursos d’água que nãoestão preparados para suportar esse novo patamar de vazões, principalmente frente a eventos de chuva extremos. Dessa forma, a modelagem hidrológica aparece como uma importante ferramenta de suporte ao planejamento e gestão. No entanto, tal ferramenta está sujeita a limitações que devem ser averiguadas por meio de calibração e validação do modelo em condições reais de campo. Este processo de calibração tem sido foco de pesquisa e discussão nos últimos 50 anos, sendo que atualmente os modelos mais aceitos são os que empregam análise de incerteza na determinação dos parâmetros. Este estudo, visa avaliar o desenvolvimento e calibração do modelo de precipitação-vazão UFGModel1.1, bem como analisar a incerteza aplicada na simulação das vazões. Para tanto, utilizou-se metodologias de análise de incerteza por meio dos métodos de Monte Carlo (MC) e Cadeia de MarkovMonte Carlo (MCMC),que formam as bases dos algoritmos GLUE e DREAM, respectivamente, paraestimação de incertezas. Os resultados demonstram que o DREAM realiza uma melhor calibração que o GLUE. Osvários conjuntos de parâmetrosencontrados, para ambos algoritmos, foram considerados ótimos para a validação do modelo, possibilitando alta eficiência deste para eventosde precipitação de médio à fortes com limites de incerteza relativamente estreitos para o DREAM e grandes para o GLUE.O parâmetro que apresentou menor sensibilidade no modelo foi o Manning do canal.
|
422 |
Algoritmo evolutivo de cromossomo duplo para calibração multivariada / Evolutive algorithm based on double chromosome for multivariate calibrationSantiago, Kelton de Sousa 05 March 2013 (has links)
Submitted by Marlene Santos (marlene.bc.ufg@gmail.com) on 2014-11-28T19:44:35Z
No. of bitstreams: 2
Dissertação - Kelton de Sousa Santiago - 2013.pdf: 1524155 bytes, checksum: d6ef69ca7d54266b0df3f43d6f5a6ced (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2014-12-04T14:17:43Z (GMT) No. of bitstreams: 2
Dissertação - Kelton de Sousa Santiago - 2013.pdf: 1524155 bytes, checksum: d6ef69ca7d54266b0df3f43d6f5a6ced (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2014-12-04T14:17:43Z (GMT). No. of bitstreams: 2
Dissertação - Kelton de Sousa Santiago - 2013.pdf: 1524155 bytes, checksum: d6ef69ca7d54266b0df3f43d6f5a6ced (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Previous issue date: 2013-03-05 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / samples and variables selection simultaneously. The algorithmic methods combination
for selecting samples and variables in the multivariate calibration aims to building an
effective model for predicting the concentration of a certain interest property.
As study case uses data acquired by a material analysis with near infrared waves (NIR)
on wheat samples in order to estimate the proteins concentration.
The algorithms for selection samples as the random number generator (RNG), KennardStone
(KS), sample set partitioning based on joint X and Y (SPXY) were used in conjunction
with successive projection algorithms (SPA) and partial least square algorithm
(PLS) for selection of variables in order to obtain results that can be used for comparison
basis with the proposed algorithm AGCD results obtained.
The presented results by samples selection algorithms (GNA, KS and SPXY) were too
close,butwhenusedtogetherwithvariableselectionalgorithms(SPAandPLS)theresults
were better in RMSEP terms.
TheAGCDachievedsignificantlybetterresultscomparedtotheotherstestedalgorithms,
reaching an improvement of 97% in comparison with the KS algorithm and an improvement
of 63% over SPXY-PLS algorithm, which further approached the AGCD results. / Este trabalho propõe o uso de um algoritmo genético de cromossomo duplo (AGCD)
paraaseleçãodeamostrasedevariáveisdeformasimultânea.Aassociaçãodosmétodos
algoritmicos para a seleção de amostras e variáveis na calibração multivariada busca a
construção de um modelo eficaz para a predição da concentração de uma determinada
propriedade de interesse.
Como estudo de caso utiliza-se dados adquiridos por uma análise de material com ondas
de infravermelho próximo (NIR) sobre amostras de trigo com o propósito de estimar a
concentração de proteínas existentes.
Os algoritmos de seleção de amostras como o gerador de números aleatórios (GNA),
Kennard-Stone(KS),particionamentodeconjuntodeamostrasbaseadanadistânciadeX
e Y (SPXY) foram utilizados em conjunto aos algoritmos de projeção sucessivas (SPA)
e o algoritmo de mínimos quadrados parciais (PLS) para seleção de variáveis, a fim de
se obter resultados que sirvam como base de comparação com os resultados obtidos pelo
algoritmo AGCD proposto.
Os resultados apresentados pelos algoritmos de seleção de amostras (GNA, KS e SPXY)
semostrarambastantepróximos,masquandoutilizadosjuntamentecomosalgoritmosde
seleção de variáveis (SPA e PLS) seus resultados foram melhores em termos de RMSEP.
O algoritmo evolutivo de cromossomo duplo (AGCD) alcançou resultados significativamentemelhoresemcomparaçãoaosdemaisalgoritmostestados,atingindoumamelhoria
de 97% em comparação com o algoritmo KS e uma melhoria de 63% sobre o algoritmo
SPXY-PLS, o que mais se aproximou dos resultados do AGCD.
|
423 |
Controle de qualidade de águas potáveis utilizando análise multivariada de imagens / Water quality control of potable water using multivariate image analysisDamasceno, Deangelis 15 December 2015 (has links)
Submitted by Cláudia Bueno (claudiamoura18@gmail.com) on 2016-05-12T18:18:17Z
No. of bitstreams: 2
Tese - Deangelis Damasceno - 2016.pdf: 4602737 bytes, checksum: 00c0eed1514b7ff11167a9271ed725e9 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-05-13T11:27:33Z (GMT) No. of bitstreams: 2
Tese - Deangelis Damasceno - 2016.pdf: 4602737 bytes, checksum: 00c0eed1514b7ff11167a9271ed725e9 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-05-13T11:27:33Z (GMT). No. of bitstreams: 2
Tese - Deangelis Damasceno - 2016.pdf: 4602737 bytes, checksum: 00c0eed1514b7ff11167a9271ed725e9 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Previous issue date: 2015-12-15 / New digital image based-analytical methodologies are proposed to measure pH,
alkalinity, total hardness, calcium hardness, magnesium hardness, chloride, fluorine,
and total iron of potable water samples. Multivariate image analysis and partial leastsquares
regression were applied to BMP digital images acquired from a CCD-scanner.
RGB, HIS, XYZ and YCbCr color spaces and 300 dpi images of 200 μL water samples
were employed. This micro volume per sample yielded micro volumes of analytical
waste per sample (400.0 μL). PLS root mean square error of prediction (RMSEP) for
pH analyses was 0.16. RMSEP values for alkalinity, total hardness, calcium hardness,
magnesium hardness, chloride, fluorine, and total iron were 0.03, 1.20, 2.01, 0.07,
0.04, and 0.06 mg L-1, respectively. Analytical figures of merit were computed for all
PLS proposed methods. Mean relative errors ranging from 0.20% to 1.33 were found.
The proposed methods were validated against standard analytical procedures for
water quality control. There were no statistical differences between mean PLS value
and the one found using the respective standard procedure (ttest, = 0.05). Precision
was found statistically equivalent for pH, alkalinity, chloride, fluoride, and total iron
when compared to the related reference method (Ftest, = 0.05). Therefore, the new
PLS analytical methods proposed for water control quality can be employed as an
alternative to standard methods. / Novas metodologias analíticas são propostas nesta Tese para a determinação físicoquímica
de pH, Alcalinidade, Dureza Total, Dureza Cálcio, Dureza Magnésio, Cloreto,
Fluoreto e Ferro Total de águas potáveis utilizando Análise Multivariada de Imagens
(MIA) associada à Regressão Multivariada por Mínimos Quadrados Parciais (PLS).
Imagens digitais de amostras obtidas por um scanner de mesa foram empregadas
para construir modelos de calibração multivariada. Amostras foram preparadas em
laboratório para cada parâmetro investigado. Os modelos PLS foram obtidos de
imagens digitais nos espaços RGB, HSI, XYZ e YCbCr, com 300 dpi de resolução e
formato de arquivo BMP. As análises foram realizadas em micro-volumes amostrais,
sendo necessários 200,0 μL de amostras por análise. O modelo PLS para
determinação do pH forneceu RMSEP = 0,16. Já para Alcalinidade, Dureza Total,
Dureza Cálcio, Dureza Magnésio, Cloreto, Fluoreto e Ferro Total os valores de
RMSEP foram iguais a 0,03, 1,20, 2,01, 0,07, 0,04 e 0,06 mg L-1, respectivamente.
Todos os modelos foram avaliados utilizando Figuras de Mérito (FOM) buscando
contemplar os parâmetros nacionais de validação de novos métodos analíticos. Para
o modelo PLS desenvolvido para determinação de pH, apresentou média dos erros
relativos obtidos da diferença entre os valores previstos e os valores de referência,
sendo igual a 0,20%. Para Alcalinidade, Dureza Total, Dureza Cálcio e Dureza
Magnésio, foram encontrados valores das médias dos erros relativos iguais a 0,85,
9,46 e 9,44%, respectivamente. Já os modelos desenvolvidos para Cloretos, Fluoretos
e Ferro, apresentaram valores menores, com médias dos erros relativos iguais a 1,01,
5,15 e 1,33%. Os modelos desenvolvidos foram validados utilizando amostras reais,
além de comparados com métodos de referência através de testes de exatidão e de
precisão. Todos os métodos desenvolvidos apresentaram exatidão estatisticamente
equivalentes aos valores obtidos pelos métodos convencionais (tcal < tcrítico, = 0,05).
Todos os modelos desenvolvidos, com exceção dos modelos de Dureza Total, Dureza
Cálcio e Dureza Magnésio, apresentaram previsão estatisticamente equivalentes aos
métodos convencionais (Fcal > Fcrítico, = 0,05). Dessa forma, as metodologias
analíticas desenvolvidas nesta Tese são alternativas aos métodos analíticos
convencionais, apresentando vantagens como menor quantidade de amostras (200,0
μL), menor quantidade de reagentes (40,0 μL), menor quantidade de solução
indicadora (4,0 μL), menor quantidade de resíduos por amostra (400,0 μL), além da
mobilidade dos métodos, não necessitando de laboratórios específicos para análise
das amostras.
|
424 |
Comparação de métodos empírico-teóricos de estimativa de evapotranspiração de referência ao modelo de Penman- Monteith / Comparison of empirical-theoretical methods of estimation of evapotranspiration reference to the Penman-Monteith modelSilva, Sérgio Soares da 29 September 2017 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2017-10-26T11:38:14Z
No. of bitstreams: 2
Dissertação - Sérgio Soares da Silva - 2017.pdf: 3227191 bytes, checksum: 2e563811d31bc63d3907c69c9b5b4c4c (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-10-26T11:39:11Z (GMT) No. of bitstreams: 2
Dissertação - Sérgio Soares da Silva - 2017.pdf: 3227191 bytes, checksum: 2e563811d31bc63d3907c69c9b5b4c4c (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-10-26T11:39:11Z (GMT). No. of bitstreams: 2
Dissertação - Sérgio Soares da Silva - 2017.pdf: 3227191 bytes, checksum: 2e563811d31bc63d3907c69c9b5b4c4c (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Previous issue date: 2017-09-29 / The reference evapotranspiration is a fundamental parameter in the calculation of the water
balance of watersheds or region as well as in determining the actual evapotranspiration of a
crop or vegetation. This climatic parameter also serves as a basis for the determination of the
volume and moment of irrigation of a crop. The objective of this research was on daily and
monthly basis to evaluate the performance and perform the calibration methods of
Hargreaves-Samani, Blaney-Criddle and Thornthwaite original and modified. The verification
of performance of the models, both in their original and calibrated forms, was by comparison
to the Penman-Monteith FAO 56 method. To evaluate the performance of the methods were
used the correlation coefficient (r), the index of agreement (d), the confidence index (c), the
mean absolute error (MAE), the mean square error (MSE), the mean square root error
(RMSE), the maximum error (ME) and the coefficient of determination (R2). For this research,
a series of data of ten years has been used from January 2007 to December 2016, and the
first five years were used to evaluate and calibrate the methods and the last five years used
to validate the adjusted methods. The meteorological data used come from a conventional
station belonging to the National Institute of Meteorology (INMET), located in the southwest of
the state of Goiás, more precisely in the city of Jataí-GO. The validation of calibration was
performed only by the Hargreaves-Samani and Blaney-Criddle models, because they had the
best adjustments over the standard Penman-Monteith FAO-56 method. / A evapotranspiração de referência é parâmetro fundamental no cômputo do balanço hídrico
de bacias hidrográficas ou região, bem como na determinação da evapotranspiração real de
uma cultura ou vegetação. Este parâmetro climatológico, serve de base também para a
determinação do volume e momento de irrigar uma cultura. O objetivo dessa pesquisa foi, em
escala diária e mensal, avaliar o desempenho e realizar a calibração dos métodos Hargreaves-
Samani, Blaney-Criddle e Thornthwaite original e modificado. A verificação do desempenho
desses modelos, tanto em suas formas originais quanto calibradas, foi por meio da
comparação ao método de Penman-Monteith FAO 56. Para avaliar o desempenho dos métodos
foram utilizados o coeficiente de correlação (r), o índice de concordância (d), o índice de
confiança (c), o erro absoluto médio (EAM), o erro quadrático médio (EQM), a raiz do erro
quadrado médio (REQM), o erro máximo (EM) e o coeficiente de determinação (R2). Para estapesquisa foi utilizada uma série de dados de dez anos, de janeiro de 2007 a dezembro de
2016, sendo que os cinco primeiros anos foram utilizados para avaliar e calibrar os métodos e
os últimos cinco anos utilizados para validar os métodos ajustados. Os dados meteorológicos
utilizados são provenientes de uma estação convencional, pertencente ao Instituto Nacional
de Meteorologia (INMET), localizada no sudoeste do estado de Goiás, mais precisamente na
cidade de Jataí-GO. A validação da calibração foi realizada apenas pelos modelos de
Hargreaves-Samani e Blaney-Criddle, pois estes tiveram os melhores ajustes em relação ao
método padrão Penman-Monteith FAO-56.
|
425 |
Modelo reduzido de sintetização de erros para máquinas de medir a três coordenadas / not availableRenata Belluzzo Zirondi 27 March 2002 (has links)
Desde sua criação por Ferranti, cerca de 50 anos atrás, as tecnologias de projeto e de fabricação das Máquinas de Medir a Três Coordenadas evoluíram muito. Entretanto, ainda é possível fabricar equipamentos livres de erros. Para garantir a acuracidade das medições realizadas é necessário que se conheça tais erros e que rotinas de compensação sejam implementadas. O levantamento dos erros de qualquer equipamento é feito através de procedimentos de calibração. Entretanto, devido à complexidade das MM3Cs, ainda não existem procedimentos internacionalmente aceitos, por usuários e fabricantes, para avaliar o desempenho metrológico desses equipamentos. Técnicas normalizadas existentes, a exemplo, JIS B 7440 de 1987, B89.4.1 de 1997, VDI/VDE 2617 de 1986 entre outras, propõem testes de desempenho que na maioria das vezes superestimam os erros da MM3C. Além disso, dificultam a rastreabilidade para quaisquer condições de medição diferente daquelas em que foi realizado o teste. Assim, diante do exposto, este trabalho tem por objetivo principal apresentar um novo modelo de sintetização de erros para MM3Cs, o Modelo Reduzido de Sintetização de erros. Este modelo possui equações de sintetização, para Ex, Ey e Ez, reduzidas, em comparação à outros modelos conhecidos, necessita de pequeno tempo na calibração o que reduz o custo desta atividade, possibilita o diagnóstico das fontes de erros e garante a rastreabilidade dos erros calculados. / Since the introduction of coordinate measuring machines by Ferranti in late fifties, the CMM design and manufacturing technology have enormously developed. Nevertheless, it is stile impossible to produce mechanical devices that are exempted from errors. In order to ensure measurements accuracy, it becomes necessary to understand such errors and establish compensation routines. The errors survey of any piece of equipment is performed by means of calibration procedures. However, due to the complexity of CMMs, there are not, until the present time, procedures that are internationally accepted by uses and manufactures to evaluate the metrological performance of this sort of equipment. Current standardized techniques, for instance, JIS B 7440 from 1987, B89.4.1. from 1997, VDI/VDE 2617 from 1986, among others, propose performance tests that usually overestimate CMM errors. Furthermore, they obstruct traceability to whatever measurement condition that is different from the ones used to perform the test. This being the case, the aim of this work comprises the presentation of the new error sinthetization model. This model deals with sinthetization equations for Ex, Ey and Ez that are reduced if compared to other known models, requires short calibration periods, reducing its expenses, allow the determination of the sources of errors and ensures traceability of calculated errors.
|
426 |
A calibração de instrumentos de medições topográficas e geodésicas: a busca pela acreditação laboratorial / The calibration of instruments topographical and geodetic measurements: the search of laboratory accreditationIara Alves Martins de Souza 06 May 2010 (has links)
É um dever dos profissionais que trabalham na área de mensuração discutir os temas que envolvem a manutenção/calibração de instrumentos geodésicos em ambiente laboratorial e o uso de padrões específicos voltados para as áreas de instrumentação e de Sistema de Gestão da Qualidade. Para isso, é importante mencionar as normas ISO 17123:2001, NBR ISO/IEC 17025:2005, ABNT NBR ISO 9001:2000 e os métodos compactos para laboratório voltados para testar estações totais e instrumentos EDM. Neste contexto, o principal objetivo desta pesquisa é discutir os temas relacionados à manutenção/calibração de instrumentos geodésicos em laboratório, mostrando a importância da implantação do Sistema de Gestão da Qualidade (SGQ). Também são discutidas as vantagens decorrentes desta implantação, bem como a organização estrutural e de pessoal para tal sistema, apresentando as normas específicas usadas para a realização de trabalhos em agrimensura. Para compreender melhor a temática da dissertação foram pesquisados alguns laboratórios internacionais que trabalham com a manutenção/calibração de instrumentos geodésicos, que são acreditados pela norma ISO 17025:2005, são certificados pelas normas ISO 9001:2000 e realizam os seus procedimentos de acordo com os requisitos da norma ISO 17123:2001. Dessa forma, as avaliações sobre a estrutura organizacional do laboratório, a estrutura de pessoal e o SGQ implantado, foram realizadas de forma mais segura. Os laboratórios pesquisados realizam suas atividades de acordo com os requisitos das normas ISO 9001:2000, ISO 17025:2005 e ISO 17123, garantindo qualidade aos trabalhos nos laboratórios. A calibração realizada de forma correta e regular contribui para a promoção da qualidade das atividades nos laboratórios. / It is the duty of professionals working in the area of measurement discuss issues involving the maintenance/calibration of geodesic instruments in the laboratory and the use of specific standards directed to the areas of instrumentation and Quality Management System. Therefore, it is important to dimensional standards ISO 17123:2001, ISO/IEC 17025:2005, ISO 9001:2000 and compact laboratory methods aimed at testing EDM instruments and total stations. In this context, the main objective of this research is to discuss issues related to maintenance/calibration of geodetic instruments in the laboratory, showing the importance of implementing the Quality Management System (QMS). Also discussed are advantages of this deployment, as well as the structural organization and personnel for such a system, with specific standards used to perform work in surveying. To better understand the theme of the thesis were searched some international laboratories that work with the maintenance/calibration of geodetic instruments, which are accredited to ISO 17025:2005 are certified by ISO 9001:2000 and realize their procedures in accordance with the requirements of ISO 17123:2001. Thus, the ratings on the organizational structure of the laboratory, the personnel structure and quality management system in place, were held more securely. The laboratories surveyed perform their activities in accordance with the requirements of ISO 9001:2000 and ISO 17025:2005 and ISO 17123, ensuring quality to work in laboratories. The calibration performed correctly and regularly contributes to the promotion of quality activities in the laboratories.
|
427 |
Estudo de calibração do questionário de frequência alimentar para adolescentes - QFAA a ser utilizado em um estudo de coorte de escolares de Piracicaba, SP / Calibration study of Adolescents Food Frequency Questionnaire AFFQ to Piracicaba students cohort, SPSilvia Maria Voci 19 September 2006 (has links)
Introdução - A maior limitação para avaliar a dieta habitual é dada pelo erro de medida. Para minimizar os seus efeitos, tem-se proposto metodologias de calibração para correção dos dados e medidas associativas, consistindo na determinação de uma relação entre duas escalas de medida, utilizando-se regressão linear. Objetivo - Calibrar os dados obtidos por Questionário de Freqüência Alimentar para Adolescentes (QFAA), a partir do fator de calibração obtido por regressão linear. Metodologia - A amostra foi constituída por 74 adolescentes de ambos os sexos, alunos de uma escola pública de Piracicaba, com idade entre 10 e 14 anos. Foram excluídos indivíduos com idade superior ou igual a 14 anos ou com dados de consumo de energia não plausíveis. Obtiveram-se informações sobre dados socioeconômicos, antropométricos, demográficos e de maturação sexual. O consumo alimentar foi levantado por meio de Questionário de Freqüência Alimentar para Adolescentes e dois Recordatórios de 24 horas. Os dados de consumo de ambos os instrumentos foram ajustados pela energia, sendo que apenas os dados do recordatório foram ajustados pela variabilidade intrapessoal. Realizaram-se análises descritivas e de tendência central, one way ANOVA, coeficientes de correlação de Pearson e regressão linear. A média dos dois recordatórios foi utilizada como referência para a calibração dos dados. Resultados - De 74 indivíduos, 71,6% eram do sexo feminino. As médias das variáveis dietéticas foram muito semelhantes para o questionário calibrado e média dos recordatórios, com redução dos valores de desvio-padrão. Os coeficientes de calibração da regressão linear variaram de -0,05 (ferro) a 0,28 (vitamina C). Conclusão Pelos resultados encontrados, a metodologia utilizada para a calibração dos dados dietéticos foi capaz de reduzir o erro de mensuração e, mesmo não o eliminando por completo, é uma abordagem que pode ser utilizada para obter estimativas menos enviesadas. / Background - A major limitation in usual diet assessment is the measurement error. Calibration approaches have been proposed to minimize its effects and to correct risk estimates. Calibration could be defined as a method which determines a relation between rank orders of two instruments by linear regression. Objective to apply a calibration strategy in nutrient intake datas obtained by Adolescents Food Frequency Questionnaire (AFFQ), by using a calibration factor obtained by linear regression. Methodology 74 boys and girls (10 to 14 years old) enrolled at a public school of Piracicaba were assessed. Values of energy intake higher than 6000Kcal and adolescents older than 14 years were excluded. Demographic and anthropometric data, sexual maturation and dietary intake (assessed by food frequency questionnaire and 24-hour recall) were examined. Dietary data intakes were adjusted by energy and, only 24-hour recall data were adjusted by within-person variance. Descriptive statistics, one way ANOVA, Pearson correlation coefficients and linear regression were performed. Results - 71,6% were girls. The calibrated values were similar to the reference data, with a reduction of standard deviation values. Linear regression coefficients (λ) ranged from -0,05 (iron) to 0,28 (vitamin C). Conclusion The methodology used to calibrate dietary data was capable to reduce measurement error. Although it was not able to eliminate error completely, it is an approach that can be used to obtain less unbiased estimates.
|
428 |
Validade, reprodutibilidade e calibração do questionário quantitativo de frequência alimentar brasileiro utilizado no estudo \"História natural da infecção por HPV em homens: o estudo HIM / Validity, reproducibility and calibration of a brazilian quantitative food frequency questionnaire used in the study Natural History of HPV Infection in Men: The HIM StudyJuliana Araujo Teixeira 31 August 2009 (has links)
Introdução. O estudo História Natural da Infecção por HPV em homens: O Estudo HIM será a primeira coorte prospectiva a investigar a história natural da infecção por HPV em homens dos Estados Unidos, Brasil e México. O questionário quantitativo de freqüência alimentar (QQFA) foi o método de escolha para a investigação do efeito dos fatores dietéticos sobre o processo da infecção. Objetivo. Avaliar o desempenho e estimar os fatores de calibração dos dados do QQFA utilizado no estudo HIM - Brasil, por meio de um estudo de validação, reprodutibilidade e calibração. Métodos. Uma amostra aleatória de 98 indivíduos do estudo HIM, com idades entre 18 e 70 anos, responderam, por meio de entrevista, a três QQFA e três recordatórios de 24 horas (R24h). O QQFA possui 54 itens alimentares e porções pré-determinadas (pequena, média, grande e extra grande). Avaliou-se a diferença entre os valores estimados pelos dois instrumentos e pelas duas aplicações do QQFA pelos coeficientes de correlação, pela concordância na classificação dos indivíduos por níveis de ingestão e pela metodologia proposta por Bland & Altman. A calibração foi feita por meio de análise de regressão linear, tendo o R24h, após deatenuação, como variável dependente e o último QQFA como variável independente, com os dados em seu logaritmo natural, ajustados pela energia. Idade, índice de massa corporal, atividade física, renda, escolaridade e o viés do relato presente no R24h foram utilizados como variáveis de ajuste nos modelos. Resultados. Os nutrientes melhor avaliados pelo QQFA foram carboidrato e fibra, com coeficientes de correlação de 0.42 e 0.46, respectivamente, para dados deatenuados. Estes nutrientes foram estimados pelo QQFA independentemente da magnitude do consumo. A estimativa da ingestão de gorduras pelo QQFA obteve os menores coeficientes de correlação e menores porcentagens de concordância entre os métodos. A análise de reprodutibilidade demonstrou que o QQFA possui precisão aceitável para avaliar a maioria dos nutrientes investigados. Os coeficientes de calibração variaram entre 0.03 para gordura total e 0.45 para fibras. O poder dos modelos (R2a) variou entre 0.01 para gordura monoinsaturada e polinsaturada e 0.81 para energia. Conclusão. Este estudo demonstrou que a medida da ingestão da população do estudo HIM Brasil por meio do QQFA avaliado é aceitável. A minimização dos erros de medida por meio da correção dos dados pela calibração é esperada. Entretanto, para analisar as relações entre os fatores dietéticos e a história da infecção por HPV em homens, dados corrigidos e não corrigidos pela calibração devem ser utilizados comparativamente. / Background. The study Natural History of HPV Infection in Men: The HIM Study will be the first prospective cohort to investigate the natural history of HPV infection in men from EUA, Brazil and Mexico. The quantitative food frequency questionnaire (QFFQ) was the method of choice to investigate the role of dietetic factors on process of infection. Objective. To assess the performance and to estimate the calibration factors from the data of QFFQ used in HIM - Brazil study, by a validation, reproducibility and calibration study. Methods. A random sample of 98 individuals from the HIM study, with age range of 18 to 70 years, by an interview, answered three QFFQ and three 24-hour recall (24h-R). The 54-item QFFQ have pre-determinate portions (small, middle, large and extra large). The difference between the estimated values from the two methods and from the two replications of QFFQ was assessed using correlation coefficients, evaluation of categorization agreement among methods and among replications and Bland & Altman plots. The calibration coefficient was calculated by regression of the 24h-R data after deattenuation (dependent variable) on the QFFQ data (independent variable) in linear regression models, with data in natural logarithm, adjusted by energy. Age, body mass index, physical activity, income, education and bias on report from 24h-R were included to adjust the multiple models. Results. Carbohydrate and fiber were well estimated by the QFFQ, with 0.42 and 0.46 in correlation coefficients, respectively, to deattenuated data. These nutrients were estimated by the QFFQ regardless of the magnitude of the intake. The consumption of fats, assessed by the QFFQ, had the worst correlation coefficients and smallest percentage agreement between the questionnaire and the 24h-R. The reproducibility analysis demonstrated that the QFFQ have acceptable precision for most of the nutrients investigated. The calibration coefficients ranged between 0.03 (total fat) and 0.45 (fiber). The power models (R2a) ranged from 0.01 (monounsaturated and polyunsaturated fat) to 0.81 (energy). Conclusion. This study demonstrated that the QFFQ is acceptable to assess nutrient intake from participants of HIM Brazil study. Minimizing bias of measurement is expected correcting the data by calibration. However, to examine the relationship between dietary factors and history of HPV infection in men, data corrected and not corrected by the calibration must be used comparatively
|
429 |
Calibração de redes de distribuição de água pelo método inverso aplicado a escoamento transiente / not availableJohn Kenedy de Araújo 24 January 2003 (has links)
Desenvolve-se um método para estimar os parâmetros de uma rede hidráulica a partir de dados observados de cargas hidráulicas transientes. Os parâmetros físicos da rede como fatores de atrito, rugosidades absolutas, diâmetros e a identificação e quantificação de vazamentos são as grandezas desconhecidas. O problema transiente inverso é resolvido utilizando uma abordagem indireta que compara os dados disponíveis de carga hidráulica transiente observados com os calculados através de um método matemático. O Método Transiente Inverso (MTI) com um Algoritmo Genético (AG) emprega o Método das Características (MOC) na solução das equações do movimento para escoamento transiente em redes de tubos. As condições de regime permanente são desconhecidas. Para avaliar a confiabilidade do MTI-AG desenvolvido aqui, uma rede-exemplo é usada para os vários problemas de calibração propostos. O comportamento transiente é imposto por duas manobras distintas de uma válvula de controle localizada em um dos nós da rede. Analisam-se, ainda, o desempenho do método proposto mediante a variabilidade do tamanho do registro transiente e de possíveis erros de leitura nas cargas hidráulicas. Ensaios numéricos realizados mostram que o método é viável e aplicável à solução de problema inverso em redes hidráulicas, sobretudo recorrendo-se a poucos dados observados e ao desconhecimento das condições iniciais de estado permanente. Nos diversos problemas de identificação, as informações transientes obtidas da manobra mais brusca produziu estimações mais eficientes. / A method for estimation of parameters of existing hydraulic networks on the basis of observed transients pressures. Such parameters include pipe friction factors or absolute roughness, their diameters and the leakage locations and discharges. The inverse transient problem in terms of unknown parameters is solved through an indirect calibration procedure, which compares the calculated and observed hydraulic heads. The search method for optimal parameters employs the Method of Characteristics for the solution equations of transient motions in pipes and Genetic Algorithms. The initial conditions in the state of equilibrium are supposed unknown and the observed transient behavior of the network is in response to a valve maneuver composed of partial closure and reestablishment of flow in a pipe. In order to validate the transient calibration method, an example network is used to test various proposed calibration problems. The results show that the proposed method can be used with confidence for determination of various kinds of parameters. The transient inverse method is capable of network calibration using transient data collected at few locations in response to a quick valve maneuver.
|
430 |
Calibração de modelos de redes de distribuição de água para abastecimento considerando vazamentos e demandas dirigidas pela pressão / Water distribution network calibration model considering leakage and head-driven demandsAlexandre Kepler Soares 27 March 2003 (has links)
No Brasil, são comuns sistemas de distribuição de água para abastecimento com elevados índices de perdas, nos quais parcela significativa das denominadas perdas físicas é devida às perdas por vazamento. Dessa maneira, o controle efetivo das perdas por vazamento e do comportamento do sistema sob as mais diversas condições operacionais é de fundamental importância, não só do ponto de vista financeiro, no que diz respeito ao desperdício da água bombeada e quimicamente tratada, mas principalmente da preservação deste recurso natural. Com o objetivo de se ter um maior conhecimento do comportamento real de uma rede de distribuição de água, técnicas de calibração, incluindo modelos para avaliação de perdas por vazamentos, vêm sendo propostas. Tais modelos devem considerar a relação pressão x vazamento, bem como a dependência pressão x demanda, face aos diferentes níveis de pressão atuantes em um sistema de distribuição de água. O presente estudo visa o desenvolvimento de uma rotina computacional que considere as perdas por vazamento e a dependência das demandas com a pressão, acoplada ao simulador hidráulico EPANET (ROSSMAN, 2000), utilizando dados de rede hipotética com vistas à calibração em termos das rugosidades absolutas, demandas, diâmetros, cotas topográficas e parâmetros do modelo de vazamentos, bem como a localização de componentes hidráulicos na rede. Para tanto, utilizam-se modelos inversos resolvidos com o suporte da tecnologia dos Algoritmos Genéticos (AGs) e procedimento híbrido (AGs e Método Simplex NELDER & MEAD, 1965) / Brazils water distribution systems usually present a high percentage of so-called physical losses, of which a significant portion is caused by leakage. Therefore, it is of fundamental importance, not only from the financial standpoint in terms of the pumped and chemically treated water but also particularly from that of the preservation of this natural resource, to effectively control leakage and the systems behavior under several operational conditions. In order to gain a better understanding of the real behavior of a water distribution network, several calibration techniques, including models to evaluate leakage, have been proposed. Those models normally consider the correlation between pressure and leakage, as well as the interdependence of pressure and demand in response to the varying levels of pressure in a water distribution system. The present study seeks to extend these models through the development of a computational routine based on leakage and on pressure-dependent demand, in conjunction with the hydraulic simulator EPANET (ROSSMAN, 2000), using the data from a hypothetical network to calibrate the absolute roughness and diameter of pipes, demands and elevations of nodes and the parameters of the leakage model, as well as the location of hydraulic components in the network. To this end, inverse models are used based on the technology of Genetic Algorithms (GA) and the hybrid procedure (GA and Simplex Method - NELDER & MEAD, 1965)
|
Page generated in 0.0826 seconds