471 |
Magnetoestratigrafia e análise espectral de ritmitos permocarboníferos da Bacia do Paraná: influências dos ciclos orbitais no regime deposicional / Magnetostratigraphy and spectral analysis of Permian-Carboniferous rhythmites from Paraná Basin: orbital cycles influence on the depositional regimeDaniel Ribeiro Franco 06 June 2007 (has links)
Este trabalho teve por objetivo investigar a escala temporal envolvida na deposição de ritmitos permocarboníferos da Bacia do Paraná (Subgrupo Itararé), expostos no Parque do Varvito (Itu, SP) e pedreira Itaú (Trombudo Central, SC), através de dados paleomagnéticos e de anisotropia de suscetibilidade magnética. Os estudos paleomagnéticos revelaram componentes de magnetização estável para ambas as coleções, com indicações de que a magnetização remanente é devida a portadores magnéticos (principalmente magnetita e hematita) de origem detrítica. A componente de magnetização característica, em ambos os casos, é de polaridade reversa, e foi identificada nos dois portadores magnéticos principais. A investigação da mineralogia magnética foi feita através de várias técnicas, incluindo espectroscopia Mossbauer, curvas termomagnéticas, curvas de histerese e ZFC/FC, além de microscopia ótica e eletrônica. Os dados paleomagnéticos e de anisotropia de susceptibilidade magnética permitiram a composição de séries temporais, que foram submetidas a análise espectral por transformada de Fourier de Lomb-Scargle para séries desigualmente espaçadas. Os espectros de potência resultantes foram posteriormente comparados com os espectros de séries de espessura individual das unidades litológicas, o que possibilitou a investigação de sinais harmônicos, sobre a qual foram propostas inferências a respeito das escalas temporais de sedimentação. Esta etapa do trabalho revelou escalas milenares para o domínio do tempo nos espectros de potência, indicando o registro dos ciclos orbitais de Milankovitch, bem como quase-periodicidades associadas à variabilidade solar e feedback do sistema oceânico-atmosférico, para todas as análises. Este conjunto de dados sugere o caráter não-anual de deposição dos ritmitos, ao contrário do proposto por alguns autores. O pólo paleomagnético calculado para a seção de Rio do Sul é compatível com o pólo do Permocarbonífero para a Bacia Sanfranciscana (MG), indicando que o intervalo de tempo envolvido na deposição dos sedimentos é suficientemente longo para eliminar os efeitos da variação secular do campo geomagnético. Alguns resultados adicionais desta tese proveram informações especiais: (i) Foram observados ciclos de indução solar (ciclos de Hallstattzein e de Suess) e a sugestão de ciclo compatível com o ciclo glacial-interglacial de Bond, recentemente sugerido como de origem solar, o que apontaria para uma possível feição harmônica, dominante sobre o sistema oceânico-atmosférico, e que poderia operar sobre períodos geológicos mais antigos; (ii) registro da remanência magnética possivelmente controlado por fatores mecânicos na sucessão de Itu, provavelmente relacionados a correntes de turbidez; (iii) indícios da presença de magnetossomas possivelmente rompidas e/ou oxidadas, em especial para a sucessão de Itu. / This work aims to investigate the timescale of the sedimentation of Permocarboniferous rhythmites from Paraná Basin (Itararé Subgroup) cropping out at the Parque do Varvito, (Itu, SP), and at the Itaú quarry, (Trombudo Central, SC) by means of paleomagnetic and anisotropy of magnetic susceptibility (ASM). The paleomagnetic study revealed stable magnetization components for both sections, which are carried by magnetic carriers (mainly magnetite and hematite) of detritic origin. The characteristic magnetization direction for each section is of reverse polarity and is found in both magnetite and hematite. Several techniques were used in the investigation the magnetic mineralogy including Mossbauer spectrometry, thermomagnetic curves, hysteresis and ZFC/FC curves, optical and electronic microscopy. Although not confirmed, some data pointed to the possibility of magnetic biomineralization with disrupted or oxidized mineral chains. The paleomagnetic and ASM data allowed the construction of time series that were submitted to spectral analysis by the Lomb-Scargle Fourier transform for unevenly spaced series. The resulting power spectra were then compared with the thickness spectrum. Based on the harmonic signals identified in all time series it was possible to infer deposition rates for both Itú and Itaú rhythmites. This procedure pointed to millennial timescale, and periodical signal compatible to Milankovitch orbital forcing, as well quasi-periodicities related to solar variability and feedback of ocean-atmospheric system, were identified in both sections. Such evidences strongly point to the non-annual sedimentation character, in opposition to previous hypothesis. The paleomagnetic data from the Rio do Sul rocks allowed the calculation of a paleomagnetic pole which is in agreement to the one recently obtained for the Santa Fé Group, Sanfranciscana Basin (MG), indicating that the time interval comprised by the Rio do Sul rhythmites is long enough for eliminating the secular variation effects. Results from this work provide also indications for the record of (i) solar forcing cycles (Hallstattzein and Suess cycles); (ii) spectral peak values of 1,5-ky and 6,0 - 8,0 ky cycle, which is compatible to the glacial-interglacial Bond cycle observed in Quaternary geological records. Such result would extend to ancient times the atmosphere-ocean interaction pattern.
|
472 |
Técnica da TDR na estimativa da umidade e condutividade elétrica de solo irrigado com água residuária da suinoculturaSoncela, Rosimaldo 30 June 2010 (has links)
Made available in DSpace on 2017-05-12T14:47:58Z (GMT). No. of bitstreams: 1
Rosimaldo Soncela.pdf: 1165359 bytes, checksum: 65125007d81deb1038c3d55926b33252 (MD5)
Previous issue date: 2010-06-30 / The swine waste water (SWW) application in soil has become an alternative fertilizer for soil and used as a water reuse. However, special attention must be given to the amount of salt content in such water since succeeding applications can stimulate the saltishness process on soil, which can ask for an indispensable monitoring of salt content in soil. The time-domain reflectometry (TDR) allows for a continuous and simultaneous monitoring of water content and apparent electric conductivity on soil (AEC), in order to make feasible the indirect determination of electric conductivity of soil solution, which can estimate salt content in the soil. Nevertheless, there is a need to obtain and calibrate a model for each type of soil. Thus, this trial aimed at obtaining a volumetric humidity calibration model for a typical Distroferric Red Latosol, as well as studying this technique viability to indirectly determine the electrical conductivity in a soil solution using an empiric equation for the TDR Trase 6050X1 devise. Calibration was performed under laboratory conditions, with deformed samples of the studied soil, conditioned in columns, with a 0.0078 m3 volume. TDR hand-made probes, with three 0.20m-long shafts, were vertically installed in the soil columns, five probes per column, totaling 16 columns. The weighing answers were obtained by digital scales and daily readings with the TDR equipment. To indirectly determine soil solution electric conductivity, deformed and saturated samples were used and saturated with SWW at 0, 10, 20, 40, 60, and 80 liters with a soil volume of 0.0225 m3. The SWW was evaporated so that saturated soil got completely dry and sieved in a 2 mm sieve to obtain the air dried fine soil (ADFS). The volumes of dried soils were conditioned in three columns to characterize T0, T1, T2, T3, T4 and T5 treatments. The same procedure was carried out for probes calibration. At that moment, four probes were installed by column, totaling 18 columns. The empirical model to estimate the volumetric soil humidity under study showed an adequate degree of determination. At last, It was possible to establish an empirical model that connected AEC recorded by the TDR equipment and electrical conductivity of saturated soil sample (ECss), making possible the use of this technique on soil salinity estimation. / A aplicação de águas residuárias de suinocultura (ARS) no solo vem sendo uma alternativa como forma de adubação e reúso de água. Entretanto, atenção especial deve ser dada à quantidade de sais contidos nessas águas, uma vez que aplicações sucessivas podem favorecer o processo de salinização do solo, tornando-se necessário um monitoramento do teor de sais no solo. A reflectometria no domínio do tempo (TDR) possibilita o monitoramento simultâneo e contínuo do teor de água e da condutividade elétrica aparente do solo (CEa) a fim de viabilizar a determinação indireta da condutividade elétrica da solução do solo, a qual possibilita a estimativa do teor de sais no solo. Porém, há necessidade de obtenção e calibração de um modelo para cada tipo de solo. Desta forma, o objetivo deste trabalho foi obter um modelo de calibração de umidade volumétrica para um Latossolo Vermelho Distroférrico Típico, bem como estudar a viabilidade da técnica na determinação indireta da condutividade elétrica da solução do solo por meio de uma equação empírica para o equipamento TDR Trase 6050X1. A calibração foi realizada em condições de laboratório, utilizando amostras deformadas do solo em estudo, acondicionadas em colunas com volume de 0,0078 m3. As sondas fabricadas artesanalmente da TDR com três hastes e 0,20 m de comprimento foram instaladas verticalmente nas colunas de solo, em um total de cinco sondas por coluna, totalizando 16 colunas. Realizaram-se as pesagens com balança digital e leituras diárias com o equipamento TDR. Para a determinação indireta da condutividade elétrica da solução do solo, foram utilizadas amostras deformadas, as quais foram saturadas com ARS nas taxas de 0, 10, 20, 40, 60 e 80 litros por um volume de 0,0225 m3 de solo. Deixou-se que a ARS evaporasse até que o solo saturado secasse totalmente, peneirado em peneira de 2 mm para formar Terra Fina Seca ao Ar (TFSA). Os volumes de solos secos foram acondicionados em três colunas, caracterizando-se os tratamentos T0, T1, T2, T3, T4 e T5. O mesmo processo ocorreu para a calibração das sondas. Nesta etapa, foram instaladas quatro sondas por coluna totalizando 18 colunas. O modelo empírico para estimativa da umidade volumétrica do solo em estudo apresentou suficiente grau de determinação. Foi possível estabelecer um modelo empírico que relacionou a condutividade elétrica aparente do solo (CETDR) e a condutividade elétrica do extrato saturado do solo (CEes) para viabilizar o uso da técnica na estimativa da salinidade do solo.
|
473 |
Utilização da técnica da reflectometria no domínio do tempo para medidas de condutividade elétrica aparente de um solo / Use of the time domain reflectometry technique for soil bulk electrical conductivity measurementsOro, Alice Leal Terres 20 July 2006 (has links)
Made available in DSpace on 2017-05-12T14:48:24Z (GMT). No. of bitstreams: 1
Alice Leal Terres Oro.pdf: 734105 bytes, checksum: 00f0a2e6f0c0139384a1298b29fdcc57 (MD5)
Previous issue date: 2006-07-20 / Measurements of solute concentrations at soils are essential to optimize
irrigation and fertilizer application, to study surface runoff and erosion and to
evaluate soil salinity. For this purpose, Time Domain Reflectometry is a
dielectric technique that has been shown to give accurate water content and
electrical conductivity values. Used under both laboratory and field conditions,
this a non-destructive essay takes simultaneous measurements of electrical
conductivity and soil water content, using a single probe and testing only one
sample region. Although there are many ways in which electrical conductivity
may be obtained with Time Domain Reflectometry equipment, few of them are
characterized by simplicity and straight forwardness. Because of that, this study
aimed to evaluate different methods to determine electrical conductivity at
solutions and soils. A sequence of laboratory experiments was conducted in
deformed soil samples of an Oxisol from West Parana State, arranged in
columns 0,30 m height, with an internal diameter of 0,19 m. The three wire
probes, with manual assembling and without impedance-matching transformer,
were vertically installed in soil columns, considering as a control one the column
which soil received only distilled water. The others treatments were defined
according to the sodium chloride content: 0,01; 0,03; 0,05; 0,07; 0,09; 0,10 and
0,15 N. The electrical conductivity was determined using waveforms collected
with specific software and there wasn t signal attenuation. It was found a linear
relationship between the bulk electrical conductivity and the pore water
electrical conductivity under constant water content. It was concluded that soils
with significant iron contents display an atypical dielectric behavior that limits
the applicability of the equipment for measuring not only soil moisture but bulk
electrical conductivity also. / Medidas de concentrações de solutos em solos são essenciais para otimizar a
irrigação e aplicações de fertilizantes, para estudar escoamento superficial e
erosão e para avaliar a salinidade do solo. Para tal fim, a Reflectometria no
Domínio do Tempo é uma técnica dielétrica que tem sido capaz de fornecer
valores precisos, tanto para teores de água como para condutividade elétrica
do solo. Empregada tanto em condições de laboratório como em condições de
campo, esta técnica não-destrutiva realiza medidas simultâneas das duas
grandezas, empregando uma única sonda e testando a mesma região da
amostra. Embora existam várias técnicas através das quais a condutividade
elétrica pode ser determinada com um equipamento de Reflectometria no
Domínio do Tempo, poucas técnicas são caracterizadas pela simplicidade e
pela rapidez. Devido a isso, o presente trabalho objetivou avaliar diferentes
métodos para a determinação da condutividade elétrica de soluções e de solos.
O trabalho foi desenvolvido em condições de laboratório, usando amostras
deformadas de um Latossolo Vermelho distroférrico da Região Oeste do
Paraná, acondicionadas em colunas com comprimento de 0,30 m e diâmetro
de 0,19 m. As sondas com 3 hastes, montadas de forma artesanal e sem
qualquer equalização de impedâncias, foram instaladas verticalmente nas
colunas de solo, sendo considerada como controle a coluna cujo solo recebeu
água destilada. Os outros tratamentos foram definidos conforme os teores de
cloreto de sódio adicionado: 0,01; 0,03; 0,05; 0,07; 0,09; 0,10 e 0,15 N. A
condutividade elétrica foi determinada a partir das formas de onda coletadas
com um programa específico e não ocorreu atenuação de sinal. Encontrou-se
uma relação linear entre as medidas de condutividade elétrica total do solo e a
condutividade elétrica da solução do solo, sob umidade constante. Também
se concluiu que solos com alto teor de Fe exibem um comportamento dielétrico
atípico, o qual limita a aplicabilidade da técnica.
|
474 |
Obtenção em larga escala de transmissores de pressão piezoresistivos de alto desempenho. / Large scale production of industrial piezoresistive pressure transmitters of high performance.Mayor Herrera, César Augusto 18 November 2013 (has links)
É apresentado um sistema para redução do tempo de calibração e compensação de sensores piezoresistivos de pressão para aplicações de automação e controle com características de alto desempenho, com compensação de diversas fontes de erro, especialmente, compensação de não-linearidade e influência da temperatura na medição, baseado em uma concepção que privilegia a precisão e exatidão da medida, a qualidade e a confiabilidade. O sistema projetado permite a automação do processo de calibração e compensação térmica de transmissores de pressão por meio de um sistema de medição e programação múltiplo, que possibilita a aquisição dos sinais em um único computador para até 16 transmissores simultâneos, aperfeiçoando o tempo total do processo, permitindo efetuar essa operação para uma produção a nível industrial. O tempo total do processo de compensação e calibração de mais de um transmissor foi reduzido em aproximadamente 6 horas por cada transmissor adicional. No caso de 16 transmissores o sistema sem multiplexação demoraria 114 horas enquanto o sistema com multiplexação demora 24 horas para efetuar o processo completo, representando uma diminuição de 78,9% no tempo total do processo. Os transmissores calibrados e compensados usando o sistema de multiplexação apresentam TEB menor que 0,1% FS, mostrando que o sistema projetado permite que os transmissores de pressão produzidos cumpram com características de desempenho iguais às atingidas pelo sistema de compensação e calibração simples. / Is presented a system for time optimization of the calibration and compensation process of piezoresistive pressure sensors for automation and control applications with high performance characteristics, with compensation of several error sources, specially, compensation of temperature dependencies and nonlinearity, based in an approach that privileges accuracy and precision in the measurements, quality and reliability. The designed system enables the automation of the calibration process and temperature compensation of pressure transmitters through a measuring and multiple programming system that enables the acquisition of signals on a single computer for up to 16 simultaneous transmitters, improving the overall process time, allowing to perform this operation for a production of industrial level. The total process time of compensation and calibration of more than one transmitter has been reduced by about 6 hours for each additional transmitter. In the case of 16 transmitters, the system without multiplexing would take 114 hours while the system with multiplexing takes 24 hours to make the entire process, representing a decrease of 78.9% in the total process time. The transmitters calibrated and compensated using the multiplexing system have TEB less than 0.1% FS, showing that the designed system allows pressure transmitters produced comply with performance characteristics equal to those achieved by the original compensation and calibration system.
|
475 |
Calibração automática de modelos em elementos finitos por meio de métodos de otimização e análise modal / Automatic calibration of finite element models through optimization methods and modal analysisRibeiro, Paula de Oliveira 25 February 2019 (has links)
O processo de calibração de parâmetros é uma importante tarefa que pode consumir bastante tempo no desenvolvimento de projetos e pesquisas. A calibração manual é um processo lento, exige experiência e, muitas vezes, não alcança a precisão desejada. Neste sentido, o presente trabalho propõe uma metodologia de calibração automática, baseada em parâmetros modais, com o intuito de tornar o processo de calibração mais eficaz e preciso. Nesta metodologia, o modelo numérico é desenvolvido em elementos finitos e os parâmetros modais experimentais são identificados por meio de ensaios dinâmicos. Com base nesses parâmetros, o modelo inicial em elementos finitos é atualizado automaticamente por meio de algoritmos de otimização até a convergência. O modelo numérico foi elaborado no software Abaqus e os algoritmos de otimização foram implementados em linguagem Python. A metodologia desenvolvida foi aplicada inicialmente na detecção de dano, sendo dano definido como uma degradação estrutural que resulta em perda parcial de rigidez de um ou vários elementos estruturais. Foram estudados exemplos numéricos e experimentais. Após a calibração da malha, das dimensões da seção transversal, das propriedades mecânicas e das rigidezes das molas, os danos foram corretamente detectados. Outra aplicação foi na investigação da anisotropia do concreto, os parâmetros modais foram obtidos por ensaio de ressonância acústica de amostras de concreto com diferentes traços (pobre, médio e rico) e direções de concretagem (horizontal e vertical). Os resultados mostraram uma clara tendência de comportamento, as amostras concretadas na horizontal foram melhor representadas por material ortotrópico e as concretadas na vertical por material isotrópico transversal no plano de concretagem. A metodologia desenvolvida obteve bons resultados nas aplicações estudadas, indicando seu potencial na calibração de estruturas reais por meio de respostas dinâmicas experimentais. / The process of parameter calibration is an important task that can be time-consuming in the development of projects and research. Manual calibration is a slow process, requires experience, and often does not achieve the desired accuracy. In this sense, the present work proposes a methodology of automatic calibration, based on modal parameters, in order to make the calibration process more efficient and accurate. In this methodology, the numerical model is developed in finite elements and the modal experimental parameters are identified by means of dynamic tests. Based on these parameters, the initial finite element model is automatically updated through optimization algorithms to convergence. The numerical model was elaborated in the software Abaqus and the algorithms of optimization were implemented in Python language. The methodology developed was initially applied in the detection of damage, being damage defined as a structural degradation that results in partial loss of rigidity of one or several structural elements. Numerical and experimental examples have been studied. After the mesh calibration, the cross-sectional dimensions, the mechanical properties and the stiffness of the springs, the damages were correctly detected. Another application was to investigate the anisotropy of concrete, the modal parameters were obtained by acoustic resonance test of concrete samples with different mixes (poor, medium and rich) and directions of concrete placement and compaction (horizontal and vertical). The results showed a clear trend of behavior, the horizontal specimens were better represented by orthotropic material and those concreted vertically by transverse isotropic material in the concreting plane. The developed methodology obtained good results in the studied applications, showing its potential in the calibration of real structures through experimental dynamic responses.
|
476 |
Inferência em um modelo de regressão com resposta binária na presença de sobredispersão e erros de medição / Inference in a regression model with overdispersed binary response and measurement errorsTieppo, Sandra Maria 15 February 2007 (has links)
Modelos de regressão com resposta binária são utilizados na solução de problemas nas mais diversas áreas. Neste trabalho enfocamos dois problemas comuns em certos conjuntos de dados e que requerem técnicas apropriadas que forneçam inferências satisfatórias. Primeiro, em certas aplicações uma mesma unidade amostral é utilizada mais de uma vez, acarretando respostas positivamente correlacionadas, responsáveis por uma variância na variável resposta superior ao que comporta a distribuição binomial, fenômeno conhecido como sobredispersão. Por outro lado, também encontramos situações em que a variável explicativa contém erros de medição. É sabido que utilizar técnicas que desconsideram esses erros conduz a resultados inadequados (estimadores viesados e inconsistentes, por exemplo). Considerando um modelo com resposta binária, utilizaremos a distribuição beta-binomial para representar a sobredispersão. Os métodos de máxima verossimilhança, SIMEX, calibração da regressão e máxima pseudo-verossimilhança foram usados na estimação dos parâmetros do modelo, que são comparados através de um estudo de simulação. O estudo de simulação sugere que os métodos de máxima verossimilhança e calibração da regressão são melhores no sentido de correção do viés, especialmente para amostras de tamanho 50 e 100. Também estudaremos testes de hipóteses assintóticos (como razão de verossimilhanças, Wald e escore) a fim de testar hipóteses de interesse. Apresentaremos também um exemplo com dados reais / Regression models with binary response are used for solving problems in several areas. In this work we approach two common problems in some data sets and they need appropriate techniques to achieve satisfactory inference. First, in some applications, the same sample unity is utilized more than once, bringing positively correlated responses, which are responsible for the response variable variance be greater than an assumption binomial distribution, phenomenon known as overdispersion. On the other hand, also we find situations where the explanatory variable has measurement errors. It is known that the use of techniques which ignores these measurement errors brings inadequate results (e. g., biased and inconsistent estimators). Taking a model with binary response, we will use a beta-binomial distribution for modeling the overdispersion. The methods of maximum likelihood, SIMEX, regression calibration and maximum pseudo-likelihood were used in the estimation of the parameters, which are compared through a simulation study. The simulation studies suggest that the maximum likelihood and regression calibration methods are better for bias correcting, especially for larger sample size. Likelihood ratio, Wald and score statistics are used in order to test hypothesis of interest. We will illustrate the techniques with an application to a real data set
|
477 |
Desenvolvimento de um Medidor de Vazão Termal Inteligente. / Development of an Intelligent Thermal Flow Meter.Marcos Antônio Andrade de Oliveira 07 July 2010 (has links)
Técnicas não-intrusivas de medição de vazão constituem uma necessidade crescente em diversas aplicações. Atualmente, diversos estudos têm sido realizados com o objetivo de desenvolver técnicas de medição não-intrusivas que possam suprir as deficiências das técnicas existentes. Este trabalho visa desenvolver um medidor de vazão baseado no princípio de convecção forçada (termal) não-intrusivo inteligente. O medidor utiliza dois transdutores RTD comerciais do tipo PT100, um aquecido, que é responsável pela medição da velocidade de escoamento, e o outro utilizado como referência de set-point de temperatura do sensor aquecido. Uma Rede Neural é responsável por corrigir os erros de medição do instrumento. Para a avaliação do medidor construído, foi desenvolvida uma bancada de realização de ensaios, possibilitando a variação da vazão e temperatura na seção de teste. Com o intuito de prover a bancada de uma referência para comparação, foi instalado também um medidor do tipo Venturi normalizado segundo a ABNT. / Non-intrusive techniques of flow measurement are very useful in several applications. Nowadays, several studies have been conducted to develop non-intrusive measuring techniques that can overcome the shortcomings of the existing ones. This work aims to design an intelligent non-intrusive flow meter device based on the forced heat convection principle (thermal). This device uses two commercial RTD transducers (PT100), one is used as reference of temperature set-point, and the other is responsible for the flow measurement. A neural network is responsible for correcting the errors in relation to the calibration standard. To evaluate the intelligent flow meter, test bench was built. In order to provide another flow meter to compare the results, an ABNT Venturi type flow meter was installed in the test bench.
|
478 |
Espectroscopia no infravermelho e método quimiométrico para a pesquisa de antimicrobianos em leite da microrregião de Pato Branco - PR / Spectroscopy infrared and chemometric method for antimicrobial research on milk of the region of Pato Branco - PRToscan, Angelisa 29 February 2016 (has links)
CAPES; CNPq / Tendo em vista a importância social e econômica que o leite possui, o objetivo do trabalho foi avaliar a incidência e quantificar resíduos de antimicrobianos neste alimento. As amostras foram coletadas em laticínios do sudoeste do estado do Paraná e desta maneira puderam-se abranger todos os dez municípios pertencentes à microrregião de Pato Branco. Os trabalhos se concentraram no desenvolvimento de modelos apropriados para a identificação e quantificação dos analitos: tetraciclina, sulfametazina, sulfadimetoxina, cloranfenicol e ampicilina, todos antimicrobianos com interesse sanitário. Para a fase de calibração e validação dos modelos foi utilizada a Espectroscopia no Infravermelho com Transformada de Fourier associada a método quimiométrico fundamentado em regressão por Mínimos Quadrados Parciais (PLS - Partial Least Squares). Para o preparo de uma solução estoque de trabalho, foram utilizados os cinco analitos de interesse em doses crescentes, a saber, tetraciclina 0 a 0,60 ppm, sulfametazina 0 a 0,12 ppm, sulfadimetoxina 0 a 2,40 ppm, cloranfenicol 0 a 1,20 ppm e ampicilina 0 a 1,80 ppm, para a realização das análises de multirresíduos. O desempenho dos modelos construídos foi avaliado através das figuras de mérito: erros quadráticos médios de calibração e de validação cruzada, coeficientes de determinação e relação de desempenho de desvio. Para efeitos de aplicabilidade no âmbito deste trabalho, considerou-se que os modelos gerados para Tetraciclina, Sulfadimetoxina e Cloranfenicol foram considerados viáveis, com maior poder de predição e eficiência, logo foram empregados para a avaliação da qualidade do leite cru da microrregião de Pato Branco. Dentre as amostras analisadas por NIR, 70 % estavam em conformidade com a legislação sanitária, sendo que 5 % destas amostras apresentaram concentrações abaixo do Limite Máximo de Resíduos permitido, sendo igualmente satisfatória. No entanto 30 % do conjunto amostral apresentou resultado insatisfatório quando avaliada a contaminação com resíduos de antimicrobianos, sendo esta não conformidade relacionada à presença de antimicrobiano de uso proibido ou com concentrações acima dos limites permitidos. Com o desenvolvimento deste trabalho pode-se dizer que a análises laboratoriais na área de alimentos, utilizando a espectroscopia no infravermelho com calibração multivariada apresenta bons resultados, com rapidez nas análises, custos reduzidos e com mínima geração de resíduos laboratoriais. Sendo assim, o método alternativo proposto vai ao encontro dos anseios de qualidade e eficiência almejados pelos setores industriais e pela sociedade de um modo geral. / Considering the social and economic importance that the milk has, the objective of this study was to evaluate the incidence and quantifying antimicrobial residues in the food. The samples were collected in dairy industry of southwestern Paraná state and thus they were able to cover all ten municipalities in the region of Pato Branco. The work focused on the development of appropriate models for the identification and quantification of analytes: tetracycline, sulfamethazine, sulfadimethoxine, chloramphenicol and ampicillin, all antimicrobials with health interest. For the calibration procedure and validation of the models was used the Infrared Spectroscopy Fourier Transform associated with chemometric method based on Partial Least Squares regression (PLS - Partial Least Squares). To prepare a work solution antimicrobials, the five analytes of interest were used in increasing doses, namely tetracycline from 0 to 0.60 ppm, sulfamethazine 0 to 0.12 ppm, sulfadimethoxine 0 to 2.40 ppm chloramphenicol 0 1.20 ppm and ampicillin 0 to 1.80 ppm to perform the work with the interest in multiresidues analysis. The performance of the models constructed was evaluated through the figures of merit: mean square error of calibration and cross-validation, correlation coefficients and offset performance ratio. For the purposes of applicability in this work, it is considered that the models generated for Tetracycline, Sulfadimethoxine and Chloramphenicol were considered viable, with the greatest predictive power and efficiency, then were employed to evaluate the quality of raw milk from the region of Pato Branco . Among the analyzed samples by NIR, 70% were in conformity with sanitary legislation, and 5% of these samples had concentrations below the Maximum Residue permitted, and is also satisfactory. However 30% of the sample set showed unsatisfactory results when evaluating the contamination with antimicrobials residues, which is non conformity related to the presence of antimicrobial unauthorized use or concentrations above the permitted limits. With the development of this work can be said that laboratory tests in the food area, using infrared spectroscopy with multivariate calibration was also good, fast in analysis, reduced costs and with minimum generation of laboratory waste. Thus, the alternative method proposed meets the quality concerns and desired efficiency by industrial sectors and society in general.
|
479 |
Calibração da potência do reator IPEN/MB-01 na configuração cilíndrica de menor excesso de reatividade obtida a partir da medida absoluta do fluxo médio de nêutrons / Power calibration of the IPEN/MB-01 reactor for the cylindrical configuration of minor reactivity excesso obtained from the measurements of the absolut average neutron fluxAlexandre Fonseca Póvoa da Silva 06 August 2014 (has links)
A ativação de folhas de ouro é uma das técnicas mais usadas para obter dados experimentais e assim comparar os resultados obtidos com aqueles calculados usando metodologias específicas e seus respectivos dados nucleares. Através da irradiação de folhas de ativação e posterior medida da atividade nelas induzida é possível determinar o fluxo de nêutrons no local da irradiação. O nível da potência de operação do reator é um parâmetro diretamente proporcional ao fluxo médio de nêutrons no núcleo do reator. O objetivo deste trabalho é obter, pela irradiação de folhas de ouro posicionadas simetricamente dentro do núcleo, utilizando a configuração cilíndrica que apresenta o menor excesso de reatividade, a potência gerada pela distribuição espacial do fluxo de nêutrons térmicos e epitérmicos no núcleo do reator IPEN/MB-01 e assim, calibrar seus canais nucleares. As folhas foram colocadas em uma placa de Lucite e irradiadas com e sem cobertura de cádmio, para se obter o valor absoluto de nêutrons térmicos e epitérmicos. A correlação entre a potência média do fluxo de nêutrons, como resultado da irradiação das folhas de ouro e, a potência média obtida a partir da aquisição de valores digitais dos canais nucleares, permite calibrar os canais nucleares do reator. Em 2008 foi feita a correlação para a configuração de núcleo retangular que resultou em uma calibração específica do nível de potência de operação para esta configuração geométrica de núcleo. Assim, esta calibração não pode ser utilizada como referência para a configuração em questão, ou seja, a cilíndrica, pois os parâmetros nucleares de distribuição de fluxo não são os mesmos, pois a distribuição difere para cada tipo de distribuição geométrica de núcleo. Além disto, o conhecimento preciso da potência de operação do reator nos permite obter os valores absolutos de fluxos de nêutrons e assim validar a metodologia de cálculo utilizada para este propósito. / The activation foils is one of the most used techniques to obtain nuclear parameters and thus compare the results with the calculated ones using specific methodologies and its nuclear data. Through the irradiation in the activation foils and ulterior measurement on its induced activity, it is possible to determine the neutron flux in the position where they were irradiated. The power level operation of the reactor is a parameter directly proportional to the average neutron flux in the core. The objective of this work is to obtain, by irradiating gold foils positioned symmetrically into the core for a cylindrical configuration, that presents the minor reactivity excess, the power generated through the spatial thermal and epitermal neutron flux distribution in the core of the IPEN/MB-01 Reactor, and thus calibrate its nuclear channels. The foils were put in a Lucite plate and irradiated with and without cadmium covered small plates, to obtain the absolute thermal and epithermal neutron flux. The correlation between the average power neutron flux, as a result of the gold foil´s irradiation and, the average power obtained by the digital values of the nuclear channels, allows the calibration of the nuclear channels of the reactor. This same correlation was done in 2008 with the reactor in a rectangular configuration, which resulted in a specific calibration of the power level operation for this geometric configuration of the core. Thus this calibration cannot be used as a reference for the actual configuration, the cylindrical one, because the nuclear parameters of the neutrons distribution are not the same, it changes for every geometric configuration of the core. Furthermore, the precise knowledge of the power neutron flux allows us to obtain absolute value of the neutron flux and thus validate the methodology used for this purpose.
|
480 |
Modelo hidrológico SWAT na bacia hidrográfica do rio Paraibuna, região da Mata Atlântica - São Paulo, Brasil / Hydrological model SWAT in the stretch Paraibuna river basin, Atlantic Forest region - São Paulo, BrazilMarmontel, Caio Vinicius Ferreira [UNESP] 03 May 2018 (has links)
Submitted by CAIO VINICIUS FERREIRA MARMONTEL (caioomarmontel@gmail.com) on 2018-05-30T19:16:14Z
No. of bitstreams: 1
tese_caiovfmarmontel.pdf: 3393744 bytes, checksum: c80daca7ae4e8871496c00cb8b548ba6 (MD5) / Approved for entry into archive by Maria Lucia Martins Frederico null (mlucia@fca.unesp.br) on 2018-06-04T13:57:05Z (GMT) No. of bitstreams: 1
marmontel_cvf_dr_botfca.pdf: 3241299 bytes, checksum: 194185ca33e9c13c6ba04b1dabe49aae (MD5) / Made available in DSpace on 2018-06-04T13:57:05Z (GMT). No. of bitstreams: 1
marmontel_cvf_dr_botfca.pdf: 3241299 bytes, checksum: 194185ca33e9c13c6ba04b1dabe49aae (MD5)
Previous issue date: 2018-05-03 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A água disponível para o consumo humano vem se tornando cada vez mais escassa, um exemplo, foi a crise hídrica iniciada em 2014 na Região Metropolitana de São Paulo. Diante desse problema, uma possibilidade de melhorar a compreensão do comportamento hidrológico, é a utilização de tecnologias, ou seja, as bases computacionais, em especial a integração do SIG com a modelagem hidrológica, por possuir um grande potencial de estimar quantitativamente a vazão. O presente estudo teve como objetivo testar a aplicabilidade do modelo hidrológico SWAT para estimação de vazões em um trecho da bacia hidrográfica do rio Paraibuna - Vale do Paraíba, região da Mata Atlântica, no estado de São Paulo. O rio Paraibuna utiliza suas águas para gerar energia elétrica e é um dos formadores do rio Paraíba do Sul, importante corpo d’água da região sudeste do Brasil. Os dados climáticos e fluviométricos foram coletados no LHFWE/PESM-NC com uma série histórica de 22 anos. O trecho da bacia hidrográfica estudada tem elevação de 974 a 1662 metros, cinco tipos de solos e três tipos de usos da terra. As avaliações dos dados observados e simulados na calibração e validação foram feitas por meio da avaliação dos gráficos-visuais de dispersão, hidrogramas e índices estatísticos pelo SWAT-CUP. Os dados gerados do balanço hídrico pelo SWAT, após a calibração foram valores próximos com a realidade. Na calibração e validação foi verificado boa aderência entre os dados simulados e observados, ou seja, os valores simulados reconheceram os picos e recessões dos valores observados. Os índices estatísticos (NS, PBIAS, RSR e R²) calculados para a calibração e validação do SWAT foram qualificados como “muito bom” para a estimação das vazões. Os resultados confirmaram a aplicabilidade do modelo, dessa forma, pode servir como ferramenta para planejamento e gestão de políticas públicas dos recursos hídricos em bacias hidrográficas, na região da Mata Atlântica. O modelo hidrológico SWAT mostrou-se muito bom e apto para estimação de vazões e do balanço hídrico no trecho da bacia hidrográfica do rio Paraibuna. / The water available for human consumption is becoming increasingly scarce, an example was the water crisis started in 2014 in the Metropolitan Region of São Paulo. Faced with this problem, one possibility to improve the understanding of hydrological behavior, is the use of technologies, that is, the computational bases, especially the integration of GIS with hydrological modeling, because it has a great potential of quantitatively estimate the flow rate. The present study had as objective to test the applicability of the SWAT hydrological model for flow estimation in the stretch of the Paraibuna river basin - Paraiba Valley, in the Atlantic Forest region, in the state of São Paulo. The Paraibuna River uses its waters to generate electricity and is one of the creators of the river South Paraiba, an important body of water in the southeastern region of Brazil. Climatic and fluviometric data were collected at the LHFWE/PESM-NC with a historical series of 22 years. The stretch of the studied basin has elevation of 974 to 1662 meters, five types of soils and three types of land use. The evaluations of the data observed and simulated in the calibration and validation were done by means of the evaluation of the visual graphics of dispersion, hydrograms and statistical indexes by SWAT-CUP. The data generated from the SWAT water balance after calibration, were close to reality. In the calibration and validation, in good adherence was observed between the simulated and observed data, that is, the simulated values recognized the peaks and recessions of the observed values. The statistical indices (NS, PBIAS, RSR and R²) calculated for SWAT calibration and validation were qualified as "very good" for the estimation of flows. The results confirmed the applicability of the model, so it can serve as a tool for planning and management of water resources public policies in watersheds, in the Atlantic Forest region. The SWAT hydrological model was very good and suitable for estimation of flow and water balance in the stretch of the Paraibuna river basin. / 1513206
|
Page generated in 0.1027 seconds