• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 92
  • 15
  • 13
  • 8
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 142
  • 142
  • 60
  • 58
  • 50
  • 50
  • 38
  • 37
  • 34
  • 30
  • 29
  • 26
  • 22
  • 21
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Análise da relação entre a posição anatômica da ponta do cateter CCIP e o motivo de remoção do dispositivo em uma coorte de neonatos / Analysis of the relation between anatomical location of PICC tip and the reason for the removal of the device in a cohort of neonates

Costa, Priscila 24 November 2011 (has links)
Introdução: O uso do Cateter Central de Inserção Periférica (CCIP) vem sendo cada vez mais frequente em neonatos internados em Unidades de Terapia Intensiva Neonatal (UTIN) em razão da necessidade de um dispositivo de acesso venoso seguro para infusão de drogas irritantes e nutrição parenteral. Detalhes técnicos do CCIP, especialmente a posição anatômica de sua ponta são descritos como fatores de risco para complicações que podem culminar em remoção não eletiva do dispositivo. Objetivo: analisar a relação entre a posição anatômica da ponta do CCIP e o motivo de remoção do dispositivo em uma coorte de neonatos. Método: coorte concorrente, composta por neonatos submetidos à instalação do CCIP, internados em UTIN de um hospital privado da cidade de São Paulo no período de 31 de agosto de 2010 a 01 de julho de 2011. Os neonatos foram incluídos no estudo no momento da instalação do cateter e acompanhados durante a permanência do dispositivo. O projeto de pesquisa foi apreciado e aprovado pelo Comitê de Ética em Pesquisa da instituição, campo do estudo (Processo 238/2010). Resultados: foram analisados dados referentes a 237 CCIPs, dos quais, 207 (86,9%) tiveram posicionamento central da ponta (grupo central) e 30 (12,5%) posição não central da ponta (grupo não central). Nos grupos central e não central, as médias da idade gestacional corrigida, idade pós-natal e peso foram, respectivamente: 34,1 semanas e 33,8 semanas; 9,9 dias e 10,4 dias; 1.936,8 gramas e 1.867 gramas, com homogeneidade entre os grupos, exceto em relação ao diagnóstico de afecção cardíaca, com maior proporção no grupo com cateter não central (p=0,0472). O sitio de inserção, tipo de cateter e terapia intravenosa instituída foram semelhantes entre os grupos. A maioria dos CCIPs (62,3%) foi removida eletivamente. A incidência de remoção não eletiva do CCIP foi maior entre os cateteres não centrais (43,3%), em comparação aos centrais (36,7%) não apresentando diferença estatisticamente significante entre os grupos (p=0,4842). O risco relativo de remoção não eletiva foi 1,18 (IC 95%: 0,76-1,84) vezes maior para os cateteres não centrais. Os principais motivos de remoção não eletiva nos cateteres centrais foram obstrução, ruptura e suspeita de infecção de corrente sanguínea relacionada a cateter, e nos cateteres não centrais foram: tração acidental, suspeita de infecção de corrente sanguínea relacionada a cateter e extravasamento. Houve diferença estatística significante quanto à incidência de extravasamento nos cateteres não centrais em relação aos centrais (p=0,0092). A taxa de incidência (TI) de extravasamento foi 0,8 por 1.000 cateteres-dia em cateteres centrais e 10,2 por 1.000 cateteres-dia nos cateteres não centrais. As médias do tempo de permanência dos cateteres não centrais e centrais foram respectivamente de 9,8 dias e 11,7 dias sem diferença estatisticamente significante (p=0,1627). Conclusão: Os achados sugeriram não haver associação entre o posicionamento não central da ponta do CCIP e a ocorrência de remoção não eletiva do cateter. Entretanto, há necessidade de avaliação permanente do neonato quanto aos sinais de extravasamento / Background: The use of Peripherally Inserted Central Catheters (PICC lines) has become common in neonates admitted to Neonatal Intensive Care Units (NICU), due to the necessity of safe intravenous access for irritant drugs and parenteral nutrition. Some technical details of the PICC, especially the anatomical location of its tip are described as risk factors for complications leading to nonelective removal of this device. Aim: Analyze the relation between anatomical location of the PICC tip and the reason for the removal of the device. Methods: Prospective cohort, composed of neonates who underwent placement of the PICC, admitted to a private NICU in the city of São Paulo, from 31 August 2010 to 1st July 2011. The infants were enrolled after successfully catheter insertion and they were followed up until its removal. The research project was appraised and approved by the Ethics Committee of the institution, (Case 238/2010). Results: Data from 237 PICCs were analyzed, 207 (86.7%) were central in tip location (central group), and 30 (12.5%) were noncentral in tip location (non central group). At central and noncentral groups, the means of corrected gestational age, postnatal age and weight were respectively: 34.1 weeks and 33.8 weeks, 9.9 days and 10.4 days, 1936. 8 grams and 1.867 grams, both groups are homogeneous, except for the diagnosis of heart disease, with the highest proportion in the noncentral group (p=0.0472). The site of insertion, type of catheter and intravenous therapy were similar in both groups. Most of PICCs (62.3%) was removed electively. The incidence of nonelective removal was higher among noncentral catheters (43.3%) compared to central (36.7%) with no statistical significant difference (p = 0.4842). The noncentral group had a 1.18-fold increased risk of nonelective removal compared to central catheters. The main reasons for nonelective removal at the central group were obstruction, rupture and suspicion of catheter-related bloodstream infection, and at the noncentral group were accidental dislodgment, suspicion of catheter-related bloodstream infection and extravasation. There was a statistically significant difference in the incidence of extravasation at the noncentral group compared to central group (p=0.0092). The extravasation rate was 0.8 per 1.000 catheter-days at central group and 10.2 per 1.000 catheter-days at noncentral group. The catheter indwelling time at noncentral and central catheters were respectively 9.8 days and 11.7 days with no statistically significant difference (p=0.1627). Conclusion: The results suggested no association between noncentral tip location of the PICC and the occurrence of nonelective removal of the catheter. However, a continuous assessment of the neonate for the signs of extravasation is needed.
52

Parecer técnico-científico: uso do conector sem agulha para sistema fechado de infusões vasculares / Technical-scientific opinion: use of the needleless connector for a closed vascular infusion system

Roque, Simone Cristina da Silva 23 February 2018 (has links)
Submitted by SIMONE CRISTINA DA SILVA SANTOS (simoneenfer2009@gmail.com) on 2019-01-31T10:36:29Z No. of bitstreams: 1 SIMONE CRISTINA DA SILVA ROQUE.pdf: 1347038 bytes, checksum: 9722d99fa9ab996c4b434e523d42e4dd (MD5) / Approved for entry into archive by Luciana Pizzani null (luciana@btu.unesp.br) on 2019-01-31T10:54:03Z (GMT) No. of bitstreams: 1 roque_scs_ms_bot.pdf: 1347038 bytes, checksum: 9722d99fa9ab996c4b434e523d42e4dd (MD5) / Made available in DSpace on 2019-01-31T10:54:03Z (GMT). No. of bitstreams: 1 roque_scs_ms_bot.pdf: 1347038 bytes, checksum: 9722d99fa9ab996c4b434e523d42e4dd (MD5) Previous issue date: 2018-02-23 / Introdução: A terapia intravenosa é um procedimento rotineiro nas instituições de saúde, requerendo, portanto, acessórios que favoreçam a realização da técnica. Dentre eles destacam-se os conectores para acesso ao sistema de infusão, uma inovação tecnológica com potencial influência nos resultados das infecções nosocomiais. Objetivo: Avaliar a evidência científica disponível sobre o uso do conector sem agulha para sistema fechado de infusões vasculares em pacientes hospitalizados em instituições de saúde. Metodologia: Foi realizada uma busca até 01 de agosto de 2017 nas bases de dados The Cochrane Library, EMBASE, PubMed e Literatura Latino-Americana e do Caribe em Ciências da Saúde (LILACS). Foram incluídos estudos de Revisões Sistemáticas (RS) e Ensaios Clínicos Randomizados (ECR). Não houve restrição de idioma e ano de publicação do artigo. Os resultados das bases de dados foram agrupados e eliminados os estudos em duplicatas. Em seguida, aplicados os critérios de elegibilidade para os títulos e resumos, restando 23 estudos para leitura completa. Após leitura dos artigos na íntegra, foram selecionados 3 estudos que comparassem os conectores sem agulha para acesso por sistema fechado e oclusores/conectores convencionais por sistema aberto e os conectores sem agulha para acesso por sistema fechado e oclusores/conectores convencionais por sistema fechado. Resultados: Para os desfechos infecção de corrente sanguínea relacionada ao cateter, colonização da ponta de cateter e colonização/contaminação da entrada de hub, não foram encontradas diferenças significativas entre os grupos. Conclusão: Considerando as evidências científicas, a recomendação da tecnologia avaliada é incerta para redução das infecções hospitalares. / Introduction: Intravenous therapy is a routine procedure in health institutions, requiring, therefore, accessories that favor the performance of the technique. Among them, the connectors for access to the infusion system, a technological innovation with potential influence on the results of nosocomial infections, stand out. Objective: To evaluate the available scientific evidence on the use of the needleless connector for closed system of vascular infusions in patients hospitalized in health institutions. Methodology: A search was performed until August 1, 2017 in the databases The Cochrane Library, EMBASE, PubMed and Latin American and Caribbean Literature in Health Sciences (LILACS). We included studies of Systematic Reviews (RS) and Randomized Clinical Trials (RCTs). There was no language restriction and year of publication of the article. The results of the databases were grouped and the duplicate studies were eliminated. Then, the eligibility criteria for the titles and abstracts were applied, leaving 23 studies for complete reading. After reading the articles in full, 3 studies comparing needleless connectors for closed system access and conventional open system occluders / connectors and needleless connectors for closed system access and conventional closed system occluders / connectors were selected. Results: For catheter-related bloodstream infection, catheter-tip colonization, and colonization / contamination of the hub entrance, no significant differences were found between groups. Conclusion: Considering the scientific evidence, the recommendation of the technology evaluated is uncertain for the reduction of hospital infections.
53

Verificação da pressão venosa central em unidade de terapia intensiva

Silva, Lidia Maria Beloni 04 August 2014 (has links)
Submitted by Fabíola Silva (fabiola.silva@famerp.br) on 2017-03-20T11:54:49Z No. of bitstreams: 1 lidiamariabelonisilva_dissert.pdf: 985957 bytes, checksum: d191961fe0b9e78f9e0c8325a666d58b (MD5) / Made available in DSpace on 2017-03-20T11:54:49Z (GMT). No. of bitstreams: 1 lidiamariabelonisilva_dissert.pdf: 985957 bytes, checksum: d191961fe0b9e78f9e0c8325a666d58b (MD5) Previous issue date: 2014-08-04 / Introduction: The bedside monitoring in the intensive care unit is considered mandatory safety technology and an indispensable tool in the management of critical patients. The recommended procedures for basic hemodynamic monitoring are: cardiac and respiratory rate, diuresis, continuous electrocardiography, oxygen saturation, noninvasive and invasive mean arterial pressure, temperature, and central venous pressure. Objective: Describe the evidence regarding the procedure of central venous pressure monitoring in the intensive care unit and identify whether there are differences in the values of the pressure with the different angles of the patient’s bedside. Method: We conducted an integrative review of the literature on the scientific databases PubMed, LILACS and SciELO, seeking idenfy scientific literature on the topic. After review, 15 articles were selected. In the second stage we conducted a prospective open study with a quantitative approach, with verification of central venous pressure in four different angles. Data are expressed as absolute numbers and percentages. Variables were analyzed with the Mann-Whitney test and the Wilcoxon test. Associations between measures were test by Pearson’s correlation coefficient (r) Results: Through the reading and discussion of the articles we identified that the monitoring can be performed with the catheter positioned in the superior vena cava and inferior device with single or multilumen, through two systems in the water column or the electronic pressure transducers. Four points should be followed in the monitoring process: mounting system, leveling, zeroing and dynamic response. The values for parameter of normal pressure must consider the point used as the phlebostatic axis and the unit of measurement used. The results should be analyzed together with other monitoring parameters and the patient’s condition. In the second stage 156 patients, checked the central venous pressure in four different angles, totaling 624 measures were included. Conclusion: Further studies are needed to identify whether there are differences between the various forms of performing the procedure, and if the values change according to the technique used. We found a positive linear correlation between the measures 0º and 30º, but in 0 ° and 45 ° the correlation is weak showing little association between the variables. / Introdução: A monitoração à beira do leito em unidade de terapia intensiva é considerada tecnologia de segurança obrigatória e ferramenta imprescindível na assistência ao paciente grave. Os procedimentos recomendados para monitoração hemodinâmica básica são: frequência cardíaca e respiratória, diurese, eletrocardiograma contínuo, saturação de oxigênio, pressão arterial média não invasiva e invasiva, frequência respiratória, temperatura e pressão venosa central. Objetivo: Descrever as evidências encontradas na literatura sobre a monitoração da pressão venosa central em unidade de terapia intensiva e identificar se existe diferença nos valores da medida com a cabeceira do leito do paciente em diferentes angulações. Método: A primeira parte da pesquisa foi constituída de um estudo descritivo de revisão integrativa da literatura nas bases de dados científicas PubMed, LILACS e SciELO, buscando idenficar a produção científica sobre o tema. Após análise, 15 artigos foram selecionados. Na segunda foi realizado um estudo prospectivo aberto, com abordagem quantitativa, com verificação da pressão venosa central em em quatro angulações diferentes. Os resultados foram apresentados em números absolutos e percentuais, as variáveis analisadas pelo Teste de Mann- Whitney e o teste Wilcoxon e a associação entre as medidas pela análise do coeficiente de correlação de Pearson (r) Resultados: Por meio de leitura e discussão dos artigos evidenciou-se que a monitoração pode ser realizada com o cateter posicionado em veia cava superior e inferior, com dispositivo uni ou multi-lúmen, por meio de dois sistemas: em coluna de água ou com transdutores eletrônicos de pressão. Quatro pontos devem ser seguidos no processo de monitoração: montagem do sistema, nivelamento, zeragem e resposta dinâmica. Os valores para parâmetro de normalidade da pressão devem considerar o ponto usado como eixo flebostático e a unidade de medida adotada. Os resultados devem ser analisados, associados a outros parâmetros de monitoração e ao quadro clínico do paciente. Na segunda etapa foram incluídos 156 pacientes, sendo verificada a PVC em quatro angulações diferentes, totalizando 624 medidas. Conclusão: Na primeira etapa ficou evidente que novos estudos são necessários para identificar se existem diferenças entre as várias formas de realizar o procedimento, e se os valores se alteram de acordo com a técnica utilizada. Na segunda etapa concluiu-se que a mensuração pode ser realizada com acurácia a 0º e 30º, pois apresentaram correlação positiva entre as medidas, porém a 0º e 45º a correlação é fraca demonstrando pouca associação entre as variáveis.
54

Adesividade e irritação cutânea do filme transparente gel de clorexidina em pacientes submetidos ao transplante de células tronco hematopoiéticas / Adhesiveness and skin rash related to the transparent film dressing with chlorhexidine gel applied to patients submitted to hematopoietic stem cell transplantation

Bruna Nogueira dos Santos 21 September 2015 (has links)
O Transplante de Células-Tronco Hematopoéticas (TCTH) trata-se da substituição das Células-Tronco Hematopoéticas (CTH) doentes de um indivíduo por CTH normais com o objetivo de normalizar a hematopoese do receptor. O cateter venoso central (CVC) tornou-se indispensável para viabilizar tal terapêutica pela segurança na infusão das CTH e dos quimioterápicos. Para o TCTH são utilizados cateteres do tipo Hickman ou duplo lúmen, ambos de longa permanência. O curativo adesivo utilizado no sítio de inserção do cateter é essencial para a fixação do cateter, proteção contra agentes externos e prevenção de infecção. Há forte evidência clínica no uso do filme transparente gel de clorexidina (CHX) como uma alternativa no controle de infecções relacionadas ao cateter. A adesividade deste curativo confere-lhe uma possível permanência de até sete dias aderido à pele, o que evita repetidas aplicações e remoções do curativo, diminui a frequência na manipulação do cateter, a ocorrência de infecção e irritação cutânea local. Observa-se que a adesividade do curativo nem sempre permite a permanência por sete dias, sendo necessárias trocas não planejadas, podendo causar lesões à integridade cutânea. Neste estudo, objetivou-se avaliar a adesividade e a irritação cutânea do filme transparente gel de CHX aplicado no sítio de inserção do CVC por meio de um estudo transversal, prospectivo, realizado em um hospital público de ensino, no período de novembro de 2013 a junho de 2014, com crianças e adultos de ambos os sexos com doenças autoimunes ou onco-hematológicas submetidos ao TCTH. A amostra desta pesquisa foi constituída por 25 pacientes. Onze (44%) apresentaram irritação cutânea caracterizada por perda de pele de extensão <=0,5cm, perda de pele de extensão > 0,5cm, placa eritematosa e vesículas. Destes, seis tiveram necessidade de suspensão do uso do curativo. A pele fragilizada devido ao uso de agentes quimioterápicos pode aderir fortemente ao curativo adesivo, sendo desprendida com o mesmo quando este é removido. A perda da integridade cutânea com remoção da camada protetora da pele facilita a entrada de microrganismos aumentando a susceptibilidade a infecções em pacientes imunossuprimidos. Em 55,6% das avaliações foi observado desprendimento do curativo e a região da fenda foi onde mais ocorreu desprendimento (43,4%). Esta é uma região da margem do curativo, assim denominada por possuir uma abertura no adesivo onde são posicionadas as vias do cateter. Infere-se que devido à mobilidade do paciente e manuseio das vias do cateter, com o passar dos dias, essa região da borda do curativo apresenta maior desprendimento. Em 8,4% das observações havia bolha de ar no gel de clorexidina envolvendo o sítio de inserção do cateter. A bolha de ar no gel de clorexidina significa que este não está em contato com a pele do paciente o que é preocupante quando envolve o sítio de inserção do cateter, pois a CHX não está exercendo sua função antisséptica neste local, onde há possibilidade de migração extra- lúmen de microrganismos à corrente sanguínea / Hematopoietic stem cell transplantation (HSCT) involves the replacement of sick hematopoietic stem cells (HSC) from an individual with normal HSC, with the aim to restore the recipient\'s hematopoiesis. Central venous catheters (CVC) have become indispensable to make this therapy feasible due to the safety of infusion of the HSC and the chemotherapeutic agents. In HSCT, long-term Hickman or long-term double lumen catheters are used. The adhesive dressing used in the site of insertion of the catheter is essential for the catheter fixation, protection against external agents and prevention of infection. There is strong clinical evidence on the use of transparent film dressing with chlorhexidine gel (CHX) as an alternative in the control of catheter-related infections. The adhesiveness of this dressing allows it to be used up to seven days once it adheres to the skin, which avoids repeated dressing applications and removals, and reduces the frequency of catheter handling, the occurrence of infection, and local skin rash. However, as observed, the dressing adhesiveness does not always allow it to be used for seven days, and unplanned replacements may be needed, which can cause lesions to the skin integrity. The objective of this study was to evaluate the adhesiveness and skin rash related to the transparent film dressing with CHX gel applied at the site of insertion of the CVC by means of a cross-sectional, prospective study developed at a public teaching hospital, between November 2013 and June 2014, with children and adults of both genders with autoimmune or onco-hematological diseases who were submitted to HSCT. The sample comprised 25 patients. Eleven (44%) presented skin rash characterized by skin loss to an extension of <=0.5 cm, skin loss to an extension of > 0.5 cm, erythematous plaque and vesicles. Of these, six had to interrupt the use of the dressing. Frail skin due to the use of chemotherapeutic agents can adhere strongly to the adhesive dressing, coming off with the dressing at its removal. The loss of skin integrity with the removal of the skin\'s protective layer facilitates the entrance of microorganisms, increasing susceptibility to infections in immunosuppressed patients. In 55.6% of the evaluations, there was dressing detachment, and it was greater in the opening region (43.4%), which is a region in the dressing border with a break in the adhesive where the catheter is placed. Given the mobility of the patient and the handling of the catheter, over the days, this region of the dressing border presents greater detachment. In 8.4% of the observations there were air bubbles in the chlorhexidine gel involving the site of insertion of the catheter. Air bubbles in the chlorhexidine gel means that it is not in contact with the patient\'s skin, which is a cause of concern when the site of insertion of a catheter is involved, since CHX is not exerting its antiseptic function in this location, which can lead to extra-lumen migration of microorganisms to the bloodstream
55

Avaliação da diferença arterio-venosa central de dióxido de carbono (ΔpCO2) como índice prognóstico em pacientes com instabilidade hemodinâmica

Araujo, David Theophilo January 2012 (has links)
INTRODUÇÃO: Instabilidade hemodinâmica é uma condição comum nos pacientes críticos e usualmente associada aos quadros de choque. O débito cardíaco (DC) é o principal determinante da oferta de oxigênio, e uma importante variável a ser monitorizada nestes pacientes. A diferença arterio-venosa central de dióxido de carbono (△pCO2), é um índice que mostrou-se correlacionar inversamente com o DC em diversos estudos. OBJETIVOS: O objetivo deste estudo é avaliar o valor prognóstico do △pCO2 (utilizando uma amostra venosa central) em uma série heterogênea de pacientes com instabilidade hemodinâmica. MÉTODOS: Estudo prospectivo observacional conduzido em uma UTI geral de 18 leitos do Complexo Hospitalar da Santa Casa de Porto Alegre. Variáveis hemodinâmicos, coleta de gasometria arterial e venosa central, e lactato, foram realizadas na admissão e após 6, 12, 18 e 24 horas. A gravidade da doença foi avaliada pelo escore APACHE II e a a severidade da disfunção orgânica pelo escore SOFA. RESULTADOS: 60 pacientes foram analisados. A mortalidade ao fim de 28 dias foi de 43% (26/60). Não se observou diferença entre os valores médios de △pCO2 entre sobreviventes e óbitos em 28 dias. O tempo de permanência na UTI foi maior entre os pacientes com um △pCO2 “alargado”. Os valores médios de saturação venosa central de oxigênio (SvcO2) foram maiores no subgrupo de pacientes com △pCO2 normal. CONCLUSÃO: Este estudo mostrou que o △pCO2, em pacientes com instabilidade hemodinâmica, está relacionado com desfecho secundários importantes como uma maior permanência em UTI. A explicação fisiológica para isso deve-se a uma maior redução no fluxo sanguíneo (como sugerido por uma SvcO2 mais baixa) causando uma oferta inadequada de oxigênio na fase aguda da doença, resultando em maior tempo de recuperação. / BACKGROUND: Hemodynamic instability is a common condition in critically ill patients and is usually associated with shock. Cardiac output (CO) is the major determinant of oxygen supply and an important variable to be monitored in these patients. The venousarterial difference of partial pressure of carbon dioxide (△pCO2) ,is an index that have shown to be inversely correlate with the CO in several studies. OBJECTIVES: This study aims to evaluate the prognostic value of the △pCO2 (using a central venous sample) in a heterogeneous series of critically ill patients with hemodynamic instability. METHODS: A prospective observational clinical study was conducted in a 18-bed general ICU of the Santa Casa de Porto Alegre Hospital Complex. Hemodynamic measurements, collection of arterial and central venous blood gases, and lactate were performed on admission and after 6 , 12, 18 and 24 hours.The severity of patient’s disease was evaluated by the APACHE II score and the level of organic disfunction was evaluated by the SOFA score. RESULTS: A total of 60 patients were analyzed. The mortality rate at 28 days was 43% (26/60). There was no difference observed in mean △pCO2 between deaths and survivors after 28 days.The ICU stay was longer among patients with “enlarged” △pCO2.Mean central venous oxygen saturation values were higher in patients with normal △pCO2. CONCLUSION: This study showed that the △pCO2 in patients with hemodynamic instability is correlated with important secondary outcomes like higher ICU stay. The physiologic explanation is a reduction on blood flow (as suggested by lower ScvO2) causing a inadequate oxygen tissue delivery in the acute phase of the disease, resulting in a greater recovery time.
56

Avaliação do biofilme de Staphylococcus spp. de cateter venoso central / Evaluation of the biofilm in Staphylococcus spp. from central venous catheter

Antunes, Ana Lucia Souza January 2011 (has links)
O gênero Staphylococcus está intimamente relacionado às infecções hospitalares onde existe a presença de implantes médicos, em especial os cateteres venosos centrais (CVC). Nestas infecções, a habilidade de formar biofilme é considerada um importante fator de virulência entre Staphylococcus. Biofilmes são agregados microbianos envolvidos por uma matriz polimérica extracelular que confere proteção contra a ação do sistema imunológico e ação dos antimicrobianos, dificultando assim o tratamento das infecções relacionadas a implantes médicos. Os objetivos deste estudo foram: (i) avaliar a formação de biofilme em 222 isolados de Staphylococcus spp. de CVC através de dois métodos fenotípicos [ágar Congo Red (ACR) e microplacas com cristal violeta] e estabelecer possíveis marcadores genéticos de formação de biofilme, através da pesquisa dos genes icaA, icaD, aap e atlE, (ii) estabelecer um teste de suscetibilidade através da técnica de microdiluição em caldo para avaliar a concentração inibitória mínima de vancomicina necessária para erradicar o biofilme formado (CMEB), e comparar estes valores com os resultados obtidos através da técnica de concentração inibitória mínima (CIM) em crescimento planctônico.Das 222 amostras analisadas, encontramos 64,5% (143/222) de isolados formadores de biofilme. A detecção de biofilme em S. epidermidis foi de 64,5% e 54% pelos métodos de microplaca e ACR respectivamente, utilizando microplacas com cristal violeta como padrão ouro. Encontramos os genes icaA e icaD na grande maioria (92% - 132/143) dos isolados produtores, o que confirma a importância destes genes na formação de biofilme. Em um total de 37 S. aureus a produção de biofilme ocorreu em 81,1% (30/37) dos isolados, sendo que entre os MRSA a taxa foi de 88,9% e entre os MSSA de 78,6%. Os genes icaA e icaD estavam presentes em 25/30 das amostras formadoras de biofilme. Nos demais Staphylococcus spp. coagulase negativos não epidermidis foi observada uma taxa de produção de biofilme de 35,6% (6/19). Os isolados formadores de biofilme foram classificados em três categorias: forte, moderado e fraco. Entre os isolados forte e moderadamente produtores de biofilme foram observados uma maior razão CMEB / CIM (> 32) frente à vancomicina. Entre isolados biofilme negativos, não encontramos diferenças nos valores de CMEB e CIM. Embora a forma de crescimento em biofilme no processo infeccioso já tenha sido bem comprovada, os laboratórios de microbiologia clínica realizam testes de suscetibilidade em isolados na forma xii planctônica. Desta forma, os resultados obtidos neste estudo, indicam que a CIM pode não ser o parâmetro mais adequado para guiar a terapêutica. Sendo assim, é extremamente importante avaliar a suscetibilidade à vancomicina, em casos de infecções relacionadas à CVC, na forma de biofilme bacteriano (CMEB). / Staphylococcus is closely related to hospital infections, where the presence of medical implants exists, here represented by central venous catheter (CVC). In these infections, the ability to form biofilm is considered an important virulence factor among Staphylococcus. Biofilms are structured communities of microbial species involved by an extracellular polymeric matrix, which protects against the immunologic system and antimicrobial actions, making it harder to treat those infections related to medical implants. The goals of this study were: (i) to evaluate the biofilm formation in 222 isolates of Staphylococcus spp. of CVC through both phenotypic methods [agar Congo Red (ACR) and microtiter plates] and establish possible genetic markers of biofilm formation, through the research of the icaA, icaD, aap and atlE genes, by PCR, (ii) establish susceptibility in biofilm, through of the microdilution test to evaluate the minimal inhibitory concentration of vancomycin to eradicate the biofilm formed - Minimal Biofilm Eradication Concentration (MBEC) and to compare these results with the values found to the Minimal Inhibitory Concentration (MIC) in growth planctonic. From the 222 analyzed samples, we found 64.5% (143/222) of isolates biofilm producers. The detection of the biofilm formation in the S. epidermidis was 64.5% and 54% by the microtiter plate and ACR methods, respectively, using microtiter plates as gold standard. We found icaA and icaD genes in most (92%) of the biofilm producing isolates, which confirms that those genes are essential for this kind of formation. In a total of 37 S. aureus, the biofilm production was observed in 81.1% (30/37) of the isolates. Concerning the MRSA we found 88.9% and among MSSA were observed 78.6% of biofilm-producing. The icaA and icaD genes were present in 25/30 of the samples biofilm producers. On the other Staphylococcus spp. coagulase negatives non-epidermidis, it was observed a number of 35.6% (6/19). The biofilm producing isolates were classified in three categories: strong, moderate and weak. Among the strong and moderate biofilm producing isolates, we could observe a higher ratio MBEC/MIC (>32) in relation to the vancomycin. Among negative biofilm isolates we found matching values for MBEC and MIC. Although the form of growth in biofilm among the infection process has already been well proven, the clinical microbiology laboratories perform susceptibility testing on isolates in the xiv planktonic form. Thus, the results of this study indicate that the MIC cannot be the most appropriate parameter to guide therapy. It is therefore extremely important to evaluate the susceptibility to vancomycin in cases of infection related to CVC, in the form of bacterial biofilms (MBEC).
57

Parecer técnico-científico uso do conector sem agulha para sistema fechado de infusões vasculares /

Roque, Simone Cristina da Silva January 2018 (has links)
Orientador: Silvana Andréa Molina Lima / Resumo: Introdução: A terapia intravenosa é um procedimento rotineiro nas instituições de saúde, requerendo, portanto, acessórios que favoreçam a realização da técnica. Dentre eles destacam-se os conectores para acesso ao sistema de infusão, uma inovação tecnológica com potencial influência nos resultados das infecções nosocomiais. Objetivo: Avaliar a evidência científica disponível sobre o uso do conector sem agulha para sistema fechado de infusões vasculares em pacientes hospitalizados em instituições de saúde. Metodologia: Foi realizada uma busca até 01 de agosto de 2017 nas bases de dados The Cochrane Library, EMBASE, PubMed e Literatura Latino-Americana e do Caribe em Ciências da Saúde (LILACS). Foram incluídos estudos de Revisões Sistemáticas (RS) e Ensaios Clínicos Randomizados (ECR). Não houve restrição de idioma e ano de publicação do artigo. Os resultados das bases de dados foram agrupados e eliminados os estudos em duplicatas. Em seguida, aplicados os critérios de elegibilidade para os títulos e resumos, restando 23 estudos para leitura completa. Após leitura dos artigos na íntegra, foram selecionados 3 estudos que comparassem os conectores sem agulha para acesso por sistema fechado e oclusores/conectores convencionais por sistema aberto e os conectores sem agulha para acesso por sistema fechado e oclusores/conectores convencionais por sistema fechado. Resultados: Para os desfechos infecção de corrente sanguínea relacionada ao cateter, colonização da ponta de cateter e col... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Introduction: Intravenous therapy is a routine procedure in health institutions, requiring, therefore, accessories that favor the performance of the technique. Among them, the connectors for access to the infusion system, a technological innovation with potential influence on the results of nosocomial infections, stand out. Objective: To evaluate the available scientific evidence on the use of the needleless connector for closed system of vascular infusions in patients hospitalized in health institutions. Methodology: A search was performed until August 1, 2017 in the databases The Cochrane Library, EMBASE, PubMed and Latin American and Caribbean Literature in Health Sciences (LILACS). We included studies of Systematic Reviews (RS) and Randomized Clinical Trials (RCTs). There was no language restriction and year of publication of the article. The results of the databases were grouped and the duplicate studies were eliminated. Then, the eligibility criteria for the titles and abstracts were applied, leaving 23 studies for complete reading. After reading the articles in full, 3 studies comparing needleless connectors for closed system access and conventional open system occluders / connectors and needleless connectors for closed system access and conventional closed system occluders / connectors were selected. Results: For catheter-related bloodstream infection, catheter-tip colonization, and colonization / contamination of the hub entrance, no significant differences were foun... (Complete abstract click electronic access below) / Mestre
58

Prolonged use of intravenous administration sets: a randomised controlled trial.

Rickard, Claire January 2004 (has links)
The purpose of this research study was to improve the nursing care of intravenous catheters by providing evidence on the effects of prolonged duration of intravenous administration set use. Intravenous therapy is a vital part of modern health care. However, its invasive nature can result in infection, with high associated morbidity and mortality. The highest infection rates are displayed in intensive care patients with central venous catheters. The duration of intravenous administration set use may have an impact on infection rates,however the current practice usage and the optimum duration of use is unknown. Previous studies of central venous catheters have reported equal infection rates with 1 to 4 days of administration set use; however few patients have been evaluated with administration sets used beyond this time. Previous research has been limited by the inadequacy of available definitions for Catheter-Related Infection. A prospective, randomised, controlled clinical trial was performed to assess the infection risk of using administration sets for prolonged periods. In the developmental phase prior to the clinical trial; definitions of Catheter-Related Bloodstream Infection (CRBSI) were developed; a nursing practice survey was undertaken to establish the current duration of administration set use; and laboratory experiments were executed to assess the impact of prolonged use on administration set physical integrity and performance. Central venous catheters were randomised to have their administration sets used for 4 days (n = 203) or 7 days (n = 201). Percutaneous central venous catheters were enrolled into the study from two adult intensive care units at a metropolitan, tertiary-referral, teaching hospital. Catheters were multiple-lumen, chlorhexidine-gluconate and silver-sulphadiazine coated lines, both inserted and removed in the intensive care unit. Catheters were cultured for microbial colonisation on removal using the Maki roll-plate technique. Patients were assessed for CRBSI using the developed definitions consisting of categories: definite, probable (type I and II), possible and absent. Prior to the clinical trial, a practice survey questionnaire was administered, and laboratory experimentation was performed. Normality of distribution for continuous variables was assessed using the Kolmogorov- Smirnov statistic. The distribution between groups of variables considered risk factors for Catheter-Related Infection were tested to assess for bias using Chi-square and T-test. Logistic regression modelling was performed to analyse the influence of potentially confounding variables. The incidence of catheter colonisation and CRBSI was tested between groups using Kaplan-Meier survival curve with Log-rank test. Paired T-tests were performed to test for difference in programmed and delivered volumes of administration sets. A general linear model (ANOVA)± a Scheffe post hoc test to isolate difference was fitted to the standardised values of delivered volumes to determine the effects of day of measurement and volume delivery rate on the accuracy of volume delivery. There were 10 colonised tips in the intervention group and 19 in the control group. This difference was not statistically significant (Kaplan Meier survival analysis, Log Rank = 0.87, df = 1, p = 0.35). There were 3 cases of CRBSI per group and the difference in survival from CRBSI was not statistically significant (Kaplan Meier with Log Rank test, p = 0.86). The pre-clinical trial phases of the research programme established that current clinical practice was 3 to 7-day use of administration sets; that administration sets were physically intact and delivered clinically accurate volumes after 7 days of use; and developed useful definitions of CRBSI. Prolonged intravenous administration set use of 7 days was found to have no significant impact on patient infection indicators or physical performance of the sets. This finding is congruent with previous research and trends in current clinical practice. In conclusion, the research findings support the use of intravenous administration sets for 7 days.
59

Förebyggande åtgärder för att minska CVK-relaterade infektioner inom intensivvården : En strukturerad litteraturstudie

Nygren, Cecilia, Nyåkers, Erika January 2018 (has links)
Bakgrund: Vårdrelaterade infektioner är ett stort problem inom dagens sjukvård och en av de vanligaste vårdrelaterade infektionerna inom intensivvården är kateterrelaterade. En central venkateter (CVK) är en kärlaccess som är vanligt förekommande inom intensivvården och handhavandet av dessa utförs till största del av sjuksköterskan. Sjuksköterskans förebyggande arbete är därför viktigt för att minska förekomsten av CVK-relaterade infektioner samt öka patientsäkerheten. Syfte: Syftet med litteraturstudien var att beskriva vilka CVK-relaterade åtgärder utförda av sjuksköterskor hos vuxna patienter inom intensivvård som minskar risken för vårdrelaterade infektioner. Metod: En strukturerad litteraturstudie som sammanställt kvantitativ forskning med en induktiv innehållsanalys. Antal studier som inkluderades i resultatet var 18 stycken. Huvudresultat: Litteraturstudiens huvudresultat baserades på fem teman, samtliga beskrev preventiva omvårdnadsåtgärder. Resultatet inom respektive tema var vikten av mekanisk rengöring med desinfektionsmedel av injektionsportar och trevägskranar, daglig utvärdering av patientens behov av en CVK, en klorhexidinkomponent i förbandet, daglig helkroppsavtvättning med tvättlappar innehållande klorhexidin samt utbildning av personalen kring evidensbaserade riktlinjer. Samtliga dessa områden sågs minska risken och förekomsten av CVK-relaterade infektioner. Slutsats: Det är angeläget att det finns sjukhusövergripande riktlinjer som baseras på den bästa tillgängliga evidensen i syfte att minska CVK-relaterade infektioner inom intensivvården. Dessa bör vara samstämmiga med de nationellt övergripande riktlinjerna. Detta för att skapa en så jämlik och patientsäker vård som möjligt. / Introduction: Healthcare-related infections are a major problem in today's healthcare and one of the most common care related infections in the intensive care unit is catheter related. A central venous catheter (CVC) is a vascular access commonly found in intensive care units, and the maintenance is commonly performed by the nurses. The preventive work is therefore important in reducing the incidence of CVC-related infections and by that increasing the patient safety.   Aim: The aim of the study was to describe what part of maintenance regarding the CVC performed by nurses in adult patients in the intensive care unit that reduces the risk of healthcare-related infections. Method: A structured literature study was conducted and studies with a quantitative design were compiled. The results were analyzed with an inductive content analysis. The number of articles included in the results were 18. Main results: The main results of the study were based on five themes which were preventive measures. The results were mechanical cleaning with disinfectants of needleless connectors and three-way stop cork, daily evaluation of the patients need for a CVC, chlorhexidine dressing, daily chlorhexidine baths and education of staff. These areas were seen to reduce the risk and incidence of CVC-related infections. Conclusion: It is important that there is a consensus of the guidelines regarding the preventions of CVC-related infections both locally and nationally. The guidelines should be based on the best available evidence to reduce CVC-related infections in the intensive care unit. The purpose is to perform equal care and to promote patient safety.
60

Nutrição parenteral como fator de risco para infecção relacionada a cateter venoso central

Beghetto, Mariur Gomes January 2003 (has links)
O uso de cateteres venosos centrais (CVC) para fins diagnósticos e terapêuticos está incorporado à prática médica diária. Complicações sérias, com elevada morbidade e mortalidade, como a sepse, estão associadas a este procedimento. O diagnóstico das infecções relacionadas a cateter é fundamentado em sinais clínicos e laboratoriais. Os fatores de risco para infecção devem ser considerados por ocasião da utilização de CVC e estão relacionados ao paciente, ao cateter, ao tipo de solução administrada, ao profissional que manipula o cateter e ao agente etiológico. A identificação destes fatores permite a intervenção precoce sobre os mesmos e o manejo adequado do CVC e das complicações clínicas relacionadas. / The use of central venous catheters (CVC) for diagnosis and treatment is common in the medical practice. This procedure is associated with severe complications that present high morbidity and mortality rates, such as sepsis. The diagnosis of catheter-related infections is based on clinical signs and laboratorial confirmation through semi-quantitative or quantitative culture of the catheter tip. The risk factors for infection should be considered when using CVC. These factors may be related to the patient, to the catheter, to the type of solution administered, to the professional who handles the catheter and to the etiological agent. The identification of these factors will early intervention and ensure adequate management of CVC- related complications.

Page generated in 0.0861 seconds