• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 84
  • 11
  • 10
  • 1
  • 1
  • Tagged with
  • 107
  • 66
  • 24
  • 20
  • 18
  • 15
  • 14
  • 13
  • 12
  • 12
  • 12
  • 12
  • 12
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Estudo de tratabilidade de lixiviado de aterro sanitário submetido à eletro-oxidação como pré-tratamento a um sistema de lodos ativados operado em batelada / Study treatability of landfill leachate subjected to electro-oxidation as a pretreatment to an activated sludge batch system

Natália de Souza Pelinson 08 November 2013 (has links)
O lixiviado de aterro sanitário é um efluente gerado a partir da mistura de líquidos produzidos na degradação de resíduos sólidos e a água pluvial que infiltra o depósito de material. Estudos na literatura, abordando tratamento de lixiviados de aterro sanitário, indicam que os processos biológicos podem não ser suficientes para que os padrões de lançamento vigentes na legislação sejam cumpridos. Neste contexto os processos oxidativos avançados estão sendo apontados como uma alternativa atrativa para efluentes que apresentam baixa biodegradabilidade. A presente pesquisa objetivou avaliar, em escala de bancada, a tratabilidade do lixiviado de aterro sanitário com aplicação do tratamento de oxidação eletroquímica seguida pelo tratamento biológico de um sistema de lodos ativados operado em batelada. A eletro-oxidação promove a remoção ou degradação de espécies poluentes, direta ou indiretamente, por meio de processos que não necessitam de adição de grandes quantidades de produtos químicos. Nos ensaios realizados com lixiviado bruto e com lixiviado alcalinizado submetido ao tratamento físico-químico de air stripping não houve necessidade de adicionar eletrólitos suporte para a oxidação química ocorrer e ao longo de tais ensaios a matéria foi mensurada quanto à DQO, COT e COD. Quando aplicada a eletro-oxidação no lixiviado bruto (sem tratamento prévio), houve 87% de remoção de DQO utilizando o anodo DDB com aplicação de 48 A h L-1 (densidade de corrente de 100 mA cm-2) e 65% de remoção da DQO quando utilizado o anodo DSA, nas mesmas condições. Analogamente, foram obtidos valores percentuais de remoção de COT de 70 e 60%, respectivamente e ainda 61 e 67% em relação ao COD. A fim de se complementar os estudos quanto à atuação da eletroquímica no tratamento do lixiviado de aterros sanitários, o efluente eletro-oxidado foi adicionado a um sistema de lodos ativados em duas proporções volumétricas distintas (2,5 e 5%) combinadas com esgoto sanitário (97,5 e 95%, respectivamente). Para controle e possível análise na eficiência, foram realizados ensaios com lixiviado bruto (5% de lixiviado bruto e 95% de esgoto sanitário) e somente esgoto sanitário (100%). Foram obtidos valores de remoção de DQO de: 75% em condição 100% esgoto sanitário, 64% com adição 2,5% de lixiviado eletro-oxidado, 57% com adição de 5% de lixiviado eletro-oxidado e 38% com adição de 5% de lixiviado bruto, além de valores percentuais de remoção de COT em cerca de 56, 52, 47 e 37%, respectivamente. E ainda foram obtida remoções nos valores de DBO na ordem de 91, 87, 64 e 24%, respectivamente. De forma geral, o sistema combinado proposto atingiu eficiências consideráveis e se mostrou compatível com o intuito de se estudar o aumento da tratabilidade por meio da aplicação de processos eletroquímicos em lixiviado bruto. / The landfill leachate is a wastewater generated from the mixture of liquids produced in the degradation of solid waste and rainwater that infiltrates the landfill. Studies in the literature approaching the treatment of landfill leachate indicate that biological processes may not be sufficient for the discharge standards prevailing in the present legislation. In this context the advanced oxidation processes (AOP) are being singled out as an attractive alternative for wastewater with a low biodegradability. This study aimed to evaluate, in a bench scale treatability of landfill leachate treatment with application of electrochemical oxidation followed by biological treatment of an activated sludge batch system. The electro-oxidation promotes the removal or degradation of pollutants species directly or indirectly, through processes which do not require addition of large amounts of chemicals. For tests with raw leachate and leachate with alkaline subjected to physico- chemical treatment of air stripping, there was no need to add support for electrolytes and chemical oxidation occurs over such trials the subject was measured as the COD, TOC and DOC. When applied the electro-oxidation in the raw leachate (without treatment) was reached 87% for COD removal using the DDB anode with the application of 48 L h-1 (current density 100 mA cm-2) and 65% COD removal when using the DSA anode under the same conditions. Similarly, the percentage values of TOC removal are 70 and 60 % respectively and also 61 and 67% compared to the DOC was obtained. In order to complement the studies regarding the performance of the electrochemical treatment of landfill leachate, the electro-oxidized effluent was added to an activated sludge system in two different volume ratios (2,5 and 5%) combined with sewage (97.5 and 95%, respectively). For control and possible efficiency analysis, testing with raw leachate (5% and 95 % crude leachate sanitary sewer) and only sanitary wastewater (100 %) were performed. Values of COD removal was obtained: 75% in 100% sewage condition, 64% with addition of 2,5% leachate electro- oxidized , with 57% addition of 5% leachate electro- oxidized and 38% with the addition of 5% raw leachate , and percentage values of TOC removal by about 56, 52, 47 and 37% , respectively. And BOD removal values were obtained in the order of 91, 87, 64 and 24%, respectively. In general, the proposed combined system has achieved considerable efficiency and proved to be compatible with the aim of studying the increased tractability through the use of electrochemical processes raw leachate.
62

Aplicação de lise celular forçada em sistema de tratamento aeróbio precedido de reator UASB

Parsekian, Marilú Pereira Serafim 09 May 2003 (has links)
Este estudo visou avaliar as implicações do uso da lise celular sobre a produção de lodos e acumulação de nutrientes no efluente do sistema combinado de tratamento (anaeróbio/aeróbio) de despejo sintético simulando esgoto sanitário. O sistema operado era constituído de reator UASB (V = 10,5 l), reator aeróbio (V = 4,4 l) e sedimentador (V = 2,7 l), operando com tempo de detenção hidráulica de 8,0 h, 3,5 h e 2,7 h respectivamente. Durante a fase de controle, acompanhou-se as características de funcionamento do processo sem o emprego da lise celular no lodo de excesso e posteriormente fez-se uso de equipamento de ultra-som para promover a lise do lodo, com retorno posterior do lodo lisado à entrada do reator UASB. Verificou-se que a eficiência média global de remoção de DQO do sistema foi de 90% em ambas as fases considerando DQO efluente filtrada. A conversão de nitrogênio amoniacal a nitrato foi pequena no tanque de aeração e a remoção de fósforo foi insignificante no processo de tratamento, no entanto não ocorreu alteração na qualidade do efluente do sistema em função do retorno do material lisado. Na escala estudada foi freqüente o aparecimento de bulking (controlado pela aplicação de hipoclorito de sódio no sedimentador), fato esse que dificultou a operação do sistema de tratamento e interferiu na manutenção do tempo de retenção celular. Os resultados obtidos da simulação realizada por meio do software GPS-X 4.0, para reator em escala real empregando a lise celular, mostraram acréscimo na concentração de fósforo total no efluente de 30% após 5 anos de operação / The aim of this research is to value the use of cell lyses over the sludge production and effluent nutrient accumulation from a combined treatment system (anaerobic/aerobic) from a synthetic sanitary wastewater. The parts of this system where one UASB reactor (V = 10,5 l), one aeration tank (V = 4,4 l) and one sedimentation tank (V = 2,7 l), hydraulic detention times of 8,0 h, 3,5 h e 2,7 h, respectively. During the control period, the characteristics of the system working without the use of cell lyses were recorded. After this phase, ultrasound equipment was used to cause the sludge lyses and then the sludge was returned to the entrance of the UASB reactor. From these tests we could not observe changes in mean global DQO removal efficiency for the both phases and it was 90% considering filtrated effluent COD. Few ammonia-nitrogen changes into nitrate inside the aeration tank were observed. Phosphorus removal in the treatment system was insignificant, but we could notice no damage to the treatment system caused by the lyses material returned. In the reduced scale of the system bulking events were frequent. This was controlled with sodium hypochlorite at the sedimentation tank, but these events caused operation difficulties and had interfered on the cellular detention time maintenance. Results from a real scale simulation, using cell lyses, done with the GPS-X 4.0 software, show an increase in effluent total phosphorus equal to 30% after 5 years
63

Microbiologia e cinética de sistema de lodos ativados como pós-tratamento de efluente de reator anaeróbio de leito expandido / Microbiology and kinetic of activated sludge system as post treatment of expanded bed anaerobic reactor

Mendonça, Luciana Coêlho 22 November 2002 (has links)
Os principais objetivos deste trabalho foram analisar o desempenho de sistema combinado (escala piloto), constituído por reator anaeróbio de leito expandido (Ralex) seguido por sistema de lodos ativados, utilizado no tratamento de esgoto sanitário, correlacionar as características da microbiota do sistema de lodos ativados com os resultados físico-químicos e determinar a cinética de consumo de substrato no sistema de lodos ativados. O desempenho do sistema combinado quanto à remoção de DQO total e DQO filtrada foi de 82% e 80%, respectivamente. No sistema combinado, a remoção de nitrogênio total foi de 65% e a remoção de fósforo foi de 35%. A população de protozoários foi bem diversificada, sendo condizente com as características operacionais do sistema de lodos ativados. Arqueas metanogênicas foram capazes de sobreviver no tanque de aeração, porém em número reduzido. O modelo cinético que melhor representou a degradação de DQO filtrada, no sistema de lodos ativados, foi o de primeira ordem com residual. A constante aparente específica média foi de 0,05L/gSSV.dia. Nas condições estudadas, não ficou evidenciado o efeito da temperatura na cinética, provavelmente devido à resistência de transferência de massa. / The major objectives of this study were: (i) to evaluate the performance of a combined system (pilot scale) treating wastewater, composed by an expanded bed anaerobic reactor and an activated sludge system; (ii) to correlate microorganisms characteristics of the activated sludge system with the physical-chemical results; and (iii) to determinate the substrate consumption kinetics of the activated sludge system. The performance of the combined system in terms of total and filtrated COD was 82% and 80% respectively. Total nitrogen removal was 65% and total phosphorous removal was 35%, in the combined system. Protozoa populations were well diversified, according to operational characteristics of activated sludge. Methanogenics archeas survived into aeration tank, but in a reduced number. First order with residual kinetic model represented the filtered COD degradation, in the activated sludge system. The mean apparent specific constant was 0,05L/gVSS.day. In this study, the effect of temperature on kinetics was not evident, probably due to mass transfer resistance.
64

Análise do desempenho na frenagem de um cavalo mecânico e semi-reboque com suspensão mecânica e sistema ABS mediante simulação em Matlab/Simulink / Analysis of the performance of tractor-semitrailer vehicles with mechanical suspension and ABS system through simulation in Matlab/Simulink

Viveros, Henry Pizarro 29 October 2010 (has links)
A presente dissertação visa analisar o desempenho na frenagem de um cavalo mecânico e semi-reboque que utiliza o sistema ABS (Antilock Braking System). Foi desenvolvido um modelo virtual de simulação utilizando a técnica dos sistemas multicorpos (Multibody System) do SimMechanics, um toolbox do Matlab/Simulink. No modelo virtual do veículo combinado foram considerados os parâmetros geométricos e mecânicos dos chassis, das suspensões, dos freios, contato pneu-pavimento e a válvula sensível à carga. São obtidas as forças normais dinâmicas no contato pneu pavimento quando o veículo está desacelerando de 20m/s até a parada completa, estas forças normais dinâmicas são entradas de uma sub-rotina em Simulink onde são calculadas as forças de frenagem, quando os freios tipo S carne são acionados. São realizadas simulações de frenagens em linha reta em pistas de média aderência (0,4) e alta aderência (0,8). As eficiências são obtidas quando o cavalo mecânico utiliza a configuração fixa de ABS tipo 6S/6M e o semi-reboque utiliza diversas configurações de ABS tipos: 2S/1M (e 4,6); 2S/2M (e 4,6); 4S/2M (e4); 4S/2M (e6); 4S/3M (e4); 4S/3M (e6); 4S/4M (e4) e 4S/4M (e6) e 6S/6M. O veículo é simulado também freando sem sistema ABS e a eficiência resultante comparada com as obtidas anteriormente. Os resultados são apresentados em figuras que mostram as forças normais dinâmicas ao pavimento, as aderências utilizadas pelos pneus e as eficiências atingidas pelas diversas configurações de ABS utilizadas no semi-reboque. Conclui-se de forma geral que configurações de ABS com mais sensores e válvulas moduladoras produzem uma eficiência maior e que a utilização de qualquer configuração de ABS como sistema complementar do sistema de freios de serviço, aumenta a eficiência de frenagem que é sempre superior ao do veículo sem sistema ABS. Esses resultados ajudam na preservação da dirigibilidade e estabilidade do veículo combinado, contribuindo assim na prevenção de acidentes de trânsito em situações de emergência. / This dissertation reports on the development of a simulation model for the analysis of the braking performance of tractor-semitrailer vehicles that use the ABS (Antilock Braking System). The model was developed using the virtual simulation technique of multibody systems with SimMechanics, a toolbox of Matlab/Simulink. In this simulation model the mechanical and geometrical parameters of the chassis, suspensions, brakes, adhesion coefficient, and load sensing valve were considered. When the vehicle is decelerating, the normal forces between the tire and road surface are obtained by the virtual model. These forces are the input of a subroutine in which the braking forces are calculated when the S Came brakes are triggered. Simulations of braking on straight line in road were made for average adhesion coefficient (0.4) and high adhesion coefficient (0.8). Efficiencies were obtained when the tractor used fixed ABS configuration of a 6S/6M type, and the semitrailer used the ABS type: 2S/lM (and 4.6); 2S/2M (and 4.6); 4S/2M (e4); 4S/2M (e6); 4S/3M (e4); 4S/3M (e6); 4S/4M (e4) and 4S/4M (e6) and 6S/6M. The results are presented in figures which show, the normal dynamic forces between tire and road, adhesions used by the tires and the efficiencies achieved by different ABS configurations installed in the semi-trailer. It is possible to conclude that in general ABS configurations with more sensors and modulating valves produce higher efficiency and the use of any configuration as a complementary system of the ABS brake system service increases the braking efficiency, which is always higher than that of a vehicle without ABS. The results help preserving the vehicle stability and maneuverability, preventing road accidents in emergency situations.
65

Análise quantitativa da degradação de fachadas em revestimento cerâmico: estudo de caso em edifícios de Belém– PA / Quantitative analysis of façade degradation in ceramic tiling: case study in buildings in Belém– PA

SANTOS NETTO, Clementino José dos 15 June 2018 (has links)
Submitted by Kelren Mota (kelrenlima@ufpa.br) on 2018-08-31T20:13:35Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseQuantitativaDegradacao.pdf: 6804477 bytes, checksum: 0896be3e55793c655408b43519e639c4 (MD5) / Approved for entry into archive by Kelren Mota (kelrenlima@ufpa.br) on 2018-08-31T20:14:11Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseQuantitativaDegradacao.pdf: 6804477 bytes, checksum: 0896be3e55793c655408b43519e639c4 (MD5) / Made available in DSpace on 2018-08-31T20:14:12Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseQuantitativaDegradacao.pdf: 6804477 bytes, checksum: 0896be3e55793c655408b43519e639c4 (MD5) Previous issue date: 2018-06-15 / Este estudo aborda o levantamento e a identificação de manifestações patológicas nas fachadas de cinco edifícios, com sistema de revestimento cerâmico (SRC), da Região Metropolitana de Belém/ PA, por meio do modelo de quantificação de danos adaptado de Silva (2014). A metodologia proposta consiste em uma sistematização do processo de inspeção, com identificação, mapeamento e quantificação das manifestações patológicas nas fachadas dos edifícios, aplicando o Fator de Danos (FD) como forma de avaliar o comportamento da degradação em função de fatores de influência como o tipo de manifestação, idade e orientação solar das fachadas, analisando também agentes de degradação como a chuva dirigida, radiação solar e umidade. Posteriormente, foi aplicado o Fator de Danos Combinado (FDC) que atribui índices de ponderação ao FD, relativos ao custo de reparação de cada anomalia observada. Analisando os resultados, verificou-se que a manifestação patológica manchas (MA) no revestimento cerâmico foi a que apresentou maior percentual de ocorrência, ou seja, maior área degradada, entre os tipos de anomalias observadas. Além disso, essa manifestação apresentou valores elevados de FDMédio em todas as orientações cardeais e valores expressivos desse índice de degradação, tanto nas fachadas com menos de 20 anos, quanto nas com mais de 20 anos. Esses resultados são diretamente influenciados pelo clima extremamente agressivo da região, que apresenta constantes chuvas e elevada umidade relativa do ar (atingindo até 95%), favorecendo a propagação dessa anomalia (manchamento) já nas primeiras idades da edificação, visto que, as fachadas mais jovens analisadas (10 e 16 anos) já possuíam índices de degradação consideráveis essa manifestação patológica. A orientação que apresentou maior fator de degradação foi a direção Sul (FDTotal=9,42%), influenciado diretamente pelo fenômeno da chuva dirigida, que apresenta seu maior Índice de Chuva Dirigida (ICD) na direção Norte, afetando as fachadas orientadas na direção Sul. Após a aplicação do FDC, a manifestação patológica descolamento/ desplacamento (DC) cerâmico passou a apresentar o maior índice de degradação (FDCMédio=39,22%), devido ao seu alto custo de restauração, quando comparado ao valor de reparo das outras anomalias avaliadas. Por meio dos histogramas de FDTotal e FDCTotal, observou-se uma curva exponencial característica que apresenta uma diminuição na frequência de ocorrência à medida que aumenta o valor do índice de degradação. Tal curva característica também foi observada em Silva (2014) e Souza (2016). / This study approaches the collect and identification of pathological manifestations in the façades of five buildings, with ceramic coating system (SRC), in the Metropolitan Region of Belém / PA, using Silva 's adapted damage quantification model (2014). The proposed methodology consists of a systematization of the inspection process, with identification, mapping and quantification of the pathological manifestations in the façades of the buildings, applying the Damage Factor (FD) as a way to evaluate the degradation behavior as a function of influence factors such as type of manifestation, age and solar orientation of the facades, also analyzing agents of degradation such as directed rain, solar radiation and humidity. Subsequently, the Combined Damage Factor (FDC) was applied, which assigns weighting indices to the FD, related to the repair cost of each observed anomaly. Analyzing the results, it was verified that the pathological manifestation stain (MA) on the ceramic coating was the one that presented the highest percentage of occurrence, that is, greater degraded area, among the types of anomalies observed. In addition, this manifestation presented high values of FDC in all cardinal orientations and expressive values of this index of degradation, both in façades under 20 years and in those with more than 20 years. These results are directly influenced by the extremely aggressive climate of the region, which presents constant rains and high humidity (up to 95%), favoring the propagation of this anomaly (staining) already in the first ages of the building, since the façades (10 and 16 years old) already had considerable degradation rates of this pathological manifestation. The orientation that presented the highest degradation factor was the South direction (FDTotal=9.42%), influenced directly by the phenomenon of directed rainfall, which presents its highest Directed Rain Index (ICD) in the North direction, affecting the facades oriented in the South direction. After the application of FDC, the pathological manifestation of ceramic detachment / displacement (DC) presented the highest degradation index (FDCMédio=39.22%), due to its high restoration cost, when compared to the repair value of the other anomalies evaluated. By means of the histograms of FDTotal and FDCTotal, a characteristic exponential curve was observed that shows a decrease in the frequency of occurrence as the value of the degradation index increases. This characteristic curve was also observed in Silva (2014) and Souza (2016).
66

Tratamento combinado de lixiviado de aterro sanitário e esgoto doméstico por processo anaeróbio em reator UASB

Miorim, Mirela 23 February 2018 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2018-04-03T16:15:47Z No. of bitstreams: 1 Mirela Miorim_.pdf: 846687 bytes, checksum: 14941a4020bedba06eadbccc896dd4d1 (MD5) / Made available in DSpace on 2018-04-03T16:15:47Z (GMT). No. of bitstreams: 1 Mirela Miorim_.pdf: 846687 bytes, checksum: 14941a4020bedba06eadbccc896dd4d1 (MD5) Previous issue date: 2018-02-23 / Nenhuma / O tratamento combinado de lixiviado de aterro sanitário (LAS) e esgoto sanitário (ES) é uma solução promissora, uma vez que com a diluição do lixiviado ocorre a redução de elevadas concentrações de nitrogênio amoniacal e matéria orgânica. No entanto, é necessário que sejam determinadas as proporções de LAS:ES adequadas para este tipo de tratamento. A presente pesquisa objetiva estudar o tratamento combinado por processo anaeróbio através de um reator anaeróbio de manta de lodo e fluxo ascendente (UASB), utilizando como substratos o esgoto sanitário e o lixiviado de aterro sanitário. A primeira etapa da pesquisa abordou os ensaios de bancada realizados, afim de caracterizar os substratos adotados e assim determinar o acréscimo de cargas orgânicas e de nutrientes, e alterações nos parâmetros físico-químicos (pH, alcalinidade e AGV) com a adição de 3 e 6% de lixiviado ao esgoto sanitário. A segunda etapa da pesquisa compreende ensaios em escala piloto, utilizando o reator UASB em regime contínuo, com 830L, operando com um TDH de 12 h,e temperatura ambiente a qual foi monitorada por um termômetro no corpo do reator. O reator UASB foi inoculado com lodo anaeróbio proveniente do reator UASB em escala plena da UNISINOS. Este lodo apresentou uma concentração de 515 mg ST/L, 265,4 mg SV/L e 250,2 mg SF/L. O reator UASB operou inicialmente apenas com esgoto sanitário por um período de 127 dias (Fase 1), em seguida operou por 49 dias com a adição de 3% de LAS (Fase 2) e a última fase por um período de 28 dias com a adição de 6% de LAS (Fase 3). Verificou-se que houve um equilíbrio no pH, alcalinidade e AGV na Fase 1, enquanto que nas Fases 2 e 3 estes parâmetros sofreram uma elevação no afluente, e um decréscimo na alcalinidade efluente devido a necessidade de se neutralizar os AGV. Foi verificada uma concentração média de alcalinidade afluente e efluente de 114,7 e 129,3 mgCaCO3/L (Fase 1), de 373,0 e 345,0 mgCaCO3/L (Fase 2) e 665,8 e 581,3 mgCaCO3/L (Fase 3), nesta ordem. O pH inicial do afluente operando somente com ES foi de 6,9, chegando a 8,8 na Fase 3 na mistura com 6% de LAS. Foi observado que o nitrogênio amoniacal afetou diretamente o processo anaeróbio, uma vez que o aumento da alcalinidade do afluente ao partir da entrada do LAS ao processo, este aumento foi atribuído a formação de hidróxido de amônia a partir do nitrogênio amoniacal presente no LAS. A concentração de nitrogênio amoniacal correspondeu a mais de 80% do nitrogênio total da mistura LAS:ES, e manteve-se nestes patamares durante todo o período experimental. As concentrações de nitrogênio amoniacal afluente e efluente, foram, respectivamente, 31,4 e 42,7 mg/L (Fase 1), 60,8 e 60,8 mg/L (Fase 2) e 91,9 e 89,4 mg/L (Fase 3). A remoção de DQO na Fase 1 variou entre 27,1 - 63,6%, de 33,7 - 54,7% na Fase 2 e de 22,9 - 32,3% na Fase 3. Para as condições estudas não verificou-se uma elevada eficiência de remoção de matéria orgânica no reator operando com a mistura LAS:ES. Quantitativamente observou-se teores de metano entre 63,2 e 74%. / The combined treatment of landfill leachate (LAS) and sanitary sewage (ES) is a promising solution, since with the dilution of the leachate the reduction of high concentrations of ammoniacal nitrogen and organic matter occurs. However, it is necessary to determine the proportions of LAS: ES suitable for this type of treatment. The present research aims to study the combined treatment by anaerobic process through an anaerobic sludge blanket and UASB reactor, using wastewater and landfill leachate as substrates. The first stage of the research was carried out in order to characterize the substrates and to determine the increase of organic loads and nutrients, as well as changes in physical and chemical parameters (pH, alkalinity and VFA) with the addition of 3 and 6% of leachate to wastewater. The second stage of the research involves pilot scale tests using the continuous UASB reactor with 830 L, operating with a HRT of 12 h, and ambient temperature which was monitored by a thermometer in the reactor. UASB reactor was inoculated with anaerobic sludge from the UASB reactor at full scale from UNISINOS, this sludge presented a concentration of 515 mg ST/L, 265.4 mg VS/L and 250.2 mg FS/L. UASB reactor initially operated only with wastewater for a period of 127 days (Phase 1), then operated for 49 days with the addition of 3% leachate (Phase 2) and the last phase for a period of 28 days with addition of 6% leachate (Stage 3). It was verified that there was a balance in pH, alkalinity and VFA in Phase 1, whereas in Phases 2 and 3 these parameters suffered an increase in the affluent, and a decrease in the alkalinity effluent due to the necessity to neutralize the VFA. A mean affluent alkalinity affluent and effluent concentration of 114.7 and 129.3 mgCaCO3/L (Phase 1), 373.0 and 345.0 mgCaCO3/L (Phase 2) and 665.8 and 581.3 mgCaCO3/L (Phase 3), in that order. The initial pH effluent operating with wastewater alone was 6.9, reaching 8.8 in Phase 3 in the mixture with 6% of leachate. It was observed that the ammonia nitrogen directly affected the anaerobic process, since the increase of the alkalinity of the affluent from the addition of the leachate to the process, this increase was attributed to the formation of ammonia hydroxide from the ammonia nitrogen present in the leachate. The concentration of ammonia nitrogen corresponded to more than 80% of the total nitrogen of the leachate/wastewater mixture, and remained at these levels throughout the experimental period. The concentrations of ammonia nitrogen affluent and effluent were respectively 31.4 and 42.7 mg/L (Phase 1), 60.8 and 60.8 mg/L (Phase 2) and 91.9 and 89.4 mg/L (Phase 3). Removal of COD in Phase 1 ranged from 27.1 - 63.6%, from 33.7 - 54.7% in Phase 2 and from 22.9 - 32.3% in Phase 3. In the conditions under study, a high removal efficiency of organic matter was not verified in the reactor operating with the leachate/wastewater mixture. Methane levels between 63.2 and 74% were quantitatively observed.
67

Análise do desempenho operacional de seguradoras que operam no ramo de automóveis: um estudo com a aplicação de índices combinados

Deis, Cibele de Paula 23 May 2011 (has links)
Made available in DSpace on 2016-04-25T18:39:39Z (GMT). No. of bitstreams: 1 Cibele de Paula Deis.pdf: 672256 bytes, checksum: 63dd609334b89d8b2e6b3f76d3f9de9a (MD5) Previous issue date: 2011-05-23 / PricewaterhouseCoopers Auditores Independentes / The purpose of this study is to analyze the performance of insurance companies operating in auto lines, during the period from 1999 to 2008. Based on the analysis of the combined and broad-based combined ratios, as well as other correlated indices (claims ratio and ratios of selling and administrative expenses), it was possible to ascertain the level of dependence on financial gains required to obtain positive results. The study was limited to insurance companies operating in auto lines, which is Brazil's most popular type of insurance and, in this context, 18 large, medium and small insurance companies were analyzed based on their financial statements. The performance of insurance companies linked to banks, as well as that of the independent companies was examined. The results of the study revealed that, during the period from 1999 to 2008, financial gains contributed from 10.19% to 17.52% to improving the operating efficiency of the insurance companies under analysis and to maintaining, for the whole period, the broad-based combined ratios below 100%. At the same time, the average combined ratios determined varied from 122.91% to 98.33%. Only in 2006 and 2007, did the sample under analysis present operating efficiency. Moreover, the insurance companies presented high operating costs, especially for claims. In a comparison between the bank-linked insurance companies and the independent insurance companies, it was noted that, on average, the selling and administrative expenses of insurance companies which use a bank branch network for distributing their products were lower than those of the independent companies comprising the sample. During the period from 2003 to 2007, the large-sized insurance companies not associated to banks revealed a gradual improvement in operating efficiency, due to the significant decrease in the claims ratio of the portfolio and a partial reduction in administrative expenses. Considering that competition is expected to become even tougher, it follows that the insurance companies will need to focus on reducing costs and improving their operating controls in order to reduce their dependence on financial results and promote the continuity of their business / O objetivo deste trabalho é analisar o desempenho operacional de seguradoras que operam no ramo de Automóveis, no período de 1999 a 2008. A partir da análise dos índices combinado e combinado ampliado, bem como dos demais índices correlatos (sinistralidade e das despesas de comercialização e administrativa) foi possível verificar o nível de dependência dos ganhos financeiros para obtenção de resultados positivos. A pesquisa foi limitada às seguradoras que atuam no ramo de Automóveis, que é o seguro mais popular no país, e, nesse contexto, foram estudadas as 18 maiores seguradoras de grande, médio e pequeno porte, tomando por base as demonstrações contábeis. Verificou-se, também, o desempenho das seguradoras ligadas a Bancos e as Independentes. Os resultados da pesquisa evidenciaram que no período de 1999 a 2008, os ganhos financeiros contribuíram de 10,19% a 17,52% para melhoria da eficiência operacional das seguradoras estudadas e, fazendo com que durante todo o período os índices combinados ampliados ficassem inferiores a 100%. Por sua vez, os índices combinados médios apurados variaram de 122,91% a 98,33%. A amostra estudada apresentou eficiência operacional, somente em relação aos exercícios de 2006 e 2007. Além disso, as seguradoras apresentaram elevados custos operacionais, especialmente, com sinistros. Na comparação das seguradoras ligadas a Bancos e independentes, observou-se que, na média, as despesas de comercialização e administrativas das seguradoras que utilizam a rede de agência dos Bancos para distribuição de seus produtos foram inferiores as demais. No período de 2003 a 2007, as seguradoras de grande porte não ligadas a Bancos mostraram uma melhoria gradual na eficiência operacional, devido à redução significativa da sinistralidade da carteira e parcialmente das despesas administrativas. Considerando que a concorrência tende a continuar ser cada vez mais acirrada, conclui-se que as seguradoras necessitam focar na redução dos custos e controles operacionais, a fim de reduzir sua dependência dos resultados financeiros e a continuidade do seu negócio
68

Flexible models for hierarchical and overdispersed data in agriculture / Modelos flexíveis para dados hierárquicos e superdispersos na agricultura

Sercundes, Ricardo Klein 29 March 2018 (has links)
In this work we explored and proposed flexible models to analyze hierarchical and overdispersed data in agriculture. A semi-parametric generalized linear mixed model was applied and compared with the main standard models to assess count data and, a combined model that take into account overdispersion and clustering through two separate sets of random effects was proposed to model nominal outcomes. For all models, the computational codes were implemented using the SAS software and are available in the appendix. / Nesse trabalho, exploramos e propusemos modelos flexíveis para a análise de dados hierárquicos e superdispersos na agricultura. Um modelo linear generalizado semi- paramétrico misto foi aplicado e comparado com os principais modelos para a análise de dados de contagem e, um modelo combinado que leva em consideração a superdispersão e a hierarquia dos dados por meio de dois efeitos aleatórios distintos foi proposto para a análise de dados nominais. Todos os códigos computacionais foram implementados no software SAS sendo disponibilizados no apêndice.
69

Controlador robusto discreto para estabilidade de quadrirrotores

Frutuoso, Adriano Bruno dos Santos 02 February 2015 (has links)
Submitted by Kamila Costa (kamilavasconceloscosta@gmail.com) on 2015-06-15T20:50:21Z No. of bitstreams: 1 Dissertacao-Adriano B dos S Frutuoso.pdf: 1799620 bytes, checksum: acda5b957dcaee1690413438f4a99e8e (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-06-16T14:58:57Z (GMT) No. of bitstreams: 1 Dissertacao-Adriano B dos S Frutuoso.pdf: 1799620 bytes, checksum: acda5b957dcaee1690413438f4a99e8e (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-06-16T15:00:11Z (GMT) No. of bitstreams: 1 Dissertacao-Adriano B dos S Frutuoso.pdf: 1799620 bytes, checksum: acda5b957dcaee1690413438f4a99e8e (MD5) / Made available in DSpace on 2015-06-16T15:00:11Z (GMT). No. of bitstreams: 1 Dissertacao-Adriano B dos S Frutuoso.pdf: 1799620 bytes, checksum: acda5b957dcaee1690413438f4a99e8e (MD5) Previous issue date: 2015-02-02 / FAPEAM - Fundação de Amparo à Pesquisa do Estado do Amazonas / This work approaches the angles stability control of a quadrotor. The vehicle parts (mechanical structure and electronic devices), dynamic modeling, controllers design methodology and the experimental results are also presented. Attitude controllers were designed using a PD/H2 discrete control structure, which the gain of H2 part was performed by solving a convex optimization problem, described in linear matrix inequalities form. The experiments indicates that angles dynamic responses can be changed by setting the gain of H2, without modifying the gains of the proportional-derivative part. The results of PD/H2 controllers were compared with a PD controller, in order to evaluate the overshoot and settling time. / Neste trabalho é abordado o controle de estabilidade dos ângulos de atitude de um MAV (Micro Aerial Vehicle) do tipo quadrirrotor. São apresentadas as partes constituintes do veículo (estrutura mecânica e dispositivos eletrônicos), a modelagem dinâmica dos ângulos de atitude, a metodologia de projeto dos controladores de atitude e os resultados experimentais. Em relação ao projeto dos controladores de atitude, estes foram projetados usando estrutura de controle discreta combinada PD/H2, cuja sintonia do controlador H2 por realimentação de estados foi realizada a partir da resolução de um problema de otimização convexo descrito na forma de desigualdades matriciais lineares. Os experimentos mostraram que as respostas dinâmicas dos ângulos de atitude poderiam ser alteradas com o ajuste dos controladores H2, sem modificar os ganhos da parte proporcional-derivativa. Os resultados obtidos para os controladores PD/H2 foram comparados com os controladores PD, de modo a avaliar os seus desempenhos com relação a tempo de acomodação e overshoot.
70

Aplicação de lise celular forçada em sistema de tratamento aeróbio precedido de reator UASB

Marilú Pereira Serafim Parsekian 09 May 2003 (has links)
Este estudo visou avaliar as implicações do uso da lise celular sobre a produção de lodos e acumulação de nutrientes no efluente do sistema combinado de tratamento (anaeróbio/aeróbio) de despejo sintético simulando esgoto sanitário. O sistema operado era constituído de reator UASB (V = 10,5 l), reator aeróbio (V = 4,4 l) e sedimentador (V = 2,7 l), operando com tempo de detenção hidráulica de 8,0 h, 3,5 h e 2,7 h respectivamente. Durante a fase de controle, acompanhou-se as características de funcionamento do processo sem o emprego da lise celular no lodo de excesso e posteriormente fez-se uso de equipamento de ultra-som para promover a lise do lodo, com retorno posterior do lodo lisado à entrada do reator UASB. Verificou-se que a eficiência média global de remoção de DQO do sistema foi de 90% em ambas as fases considerando DQO efluente filtrada. A conversão de nitrogênio amoniacal a nitrato foi pequena no tanque de aeração e a remoção de fósforo foi insignificante no processo de tratamento, no entanto não ocorreu alteração na qualidade do efluente do sistema em função do retorno do material lisado. Na escala estudada foi freqüente o aparecimento de bulking (controlado pela aplicação de hipoclorito de sódio no sedimentador), fato esse que dificultou a operação do sistema de tratamento e interferiu na manutenção do tempo de retenção celular. Os resultados obtidos da simulação realizada por meio do software GPS-X 4.0, para reator em escala real empregando a lise celular, mostraram acréscimo na concentração de fósforo total no efluente de 30% após 5 anos de operação / The aim of this research is to value the use of cell lyses over the sludge production and effluent nutrient accumulation from a combined treatment system (anaerobic/aerobic) from a synthetic sanitary wastewater. The parts of this system where one UASB reactor (V = 10,5 l), one aeration tank (V = 4,4 l) and one sedimentation tank (V = 2,7 l), hydraulic detention times of 8,0 h, 3,5 h e 2,7 h, respectively. During the control period, the characteristics of the system working without the use of cell lyses were recorded. After this phase, ultrasound equipment was used to cause the sludge lyses and then the sludge was returned to the entrance of the UASB reactor. From these tests we could not observe changes in mean global DQO removal efficiency for the both phases and it was 90% considering filtrated effluent COD. Few ammonia-nitrogen changes into nitrate inside the aeration tank were observed. Phosphorus removal in the treatment system was insignificant, but we could notice no damage to the treatment system caused by the lyses material returned. In the reduced scale of the system bulking events were frequent. This was controlled with sodium hypochlorite at the sedimentation tank, but these events caused operation difficulties and had interfered on the cellular detention time maintenance. Results from a real scale simulation, using cell lyses, done with the GPS-X 4.0 software, show an increase in effluent total phosphorus equal to 30% after 5 years

Page generated in 0.0655 seconds