• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1493
  • 30
  • 10
  • 8
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 4
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 1553
  • 1199
  • 895
  • 812
  • 377
  • 353
  • 342
  • 326
  • 311
  • 246
  • 207
  • 180
  • 162
  • 160
  • 158
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
301

Estudo da anatomia dental por meio da tomografia computadorizada de feixe-cônico de indivíduos residentes em São Paulo / Study of dental anatomy by cone-beam CT of individuals living in São Paulo

Ferreira, Felipe Potgornik 24 September 2012 (has links)
A grande diversidade existente na cidade de São Paulo Brasil, torna esta cidade um interessante campo para estudos anatômicos em geral. Este estudo teve por objetivo avaliar a morfologia dental interna desta população e suas variações em função do sexo e idade. Foram analisadas 2102 imagens tomográficas obtidas por meio de dois tomógrafos (i-Cat e PreXion) de pacientes que se submeteram ao procedimento diagnóstico por motivos diversos. Todos os grupos dentais foram avaliados individualmente e divididos quanto ao sexo (masculino e feminino) e quanto a idade (18-29, 30-39, 40-49, 50-59, 60-69 e 70-80 anos). O número de raízes foi determinado e a morfologia interna classificada em oito tipos: tipo I (1), tipo II (2-1), tipo III (1-2-1), tipo IV (2), tipo V (1-2), tipo VI (2-1-2), tipo VII (1-2-1-2) e tipo VIII (3), observando-se ainda se a variação anatômica era bilateral. Os resultados foram descritos em tabelas na forma de porcentagem. Pode-se concluir que a anatomia dental interna parece não sofrer influência da idade do indivíduo e pode sofrer influência quanto ao sexo em algumas situações, entretanto a morfologia interna é complexa, sendo que a população da cidade de São Paulo apresenta diferenças anatômicas quando comparada às populações descritas na literatura. / The great diversity in the city of Sao Paulo - Brazil, makes this city an interesting field for anatomical studies. This study aimed to evaluate the internal dental morphology of this population and sex and age variations We analyzed 2102 CT images obtained using two scanners (i-Cat and PreXion) of patients who underwent the diagnostic procedure for several reasons. All dental groups were analized individually and divided by gender (male and female) and by age (18-29, 30-39, 40-49, 50-59, 60-69 and 70-80 years). The number of roots were determined and the internal morphology classified into eight types: type I (1), type II (2-1), type III (1-2-1), type IV (2), type V (1-2), type VI (2-1-2), type VII (1-2-1-2), type VIII (3). Also was observed if anatomical differences was bilateral. The results were reported in the tables as a percentage. The conclusion is that the internal dental anatomy is not influenced by age and can be influenced by sex in some situations, however the internal morphology is complex, and the population of São Paulo presents anatomical differences when compared to populations described in the literature.
302

Avaliação, por meio de microtomografia computadorizada, da anatomia interna de dentes anteriores superiores / Micro-computed tomography analysis of the internal anatomy of maxillary anterior teeth

Chaves, Jardel Francisco Mazzi 29 January 2015 (has links)
O estudo da anatomia interna do complexo sistema de canais radiculares (SCR) é de fundamental importância no diagnóstico, planejamento e tratamento endodôntico. O objetivo deste estudo foi avaliar a anatomia do SCR de incisivos centrais, laterais e caninos superiores, por meio de microtomografia computadorizada (&mu;TC). Foram usados 50 incisivos centrais (ICS), 50 laterais (ILS) e 50 caninos superiores (CS), escaneados no microtomógrafo SkyScan 1174. Os espécimes foram reconstruídos e analisados os parâmetros bidimensionais (número, área, circularidade, fator de forma, diâmetro maior, diâmetro menor) a 1, 2, 3, 4 e 5 mm do forame apical e tridimensionais (volume, área de superfície, SMI, número e localização de canais acessórios, localização e volume do ombro palatino), bem como as características anatômicas externas dos dentes (comprimento, dimensões da coroa, curvatura radicular, posição do forame, presença, localização, profundidade e extensão dos sulcos) e análise qualitativa da anatomia interna dos modelos tridimensionais. Os resultados bidimensionais mostraram a presença de um canal no terço apical nos três grupos dentais estudados. Os valores de circularidade e fator de forma evidenciaram forma circular dos canais no terço apical tanto para os ICS quanto para os CS, com tendência ao achatamento destes canais no terço apical nos ILS. O teste de regressão linear evidenciou aumento progressivo dos diâmetros maior e menor nos 5 milímetros avaliados (p<0,001), com aumentos respectivos de 0,09 mm e 0,07 mm para os ICS; 0,12 mm e 0,07 mm para os ILS e 0,11 mm e 0,06 mm para os CS. A análise tridimensional demonstrou que as maiores médias de volume (mm3) e área de superfície (mm²) foram encontradas nos CS. Os valores de SMI foram semelhantes para os três grupos, sugerindo forma tridimensional com tendência a um cilindro. Os modelos tridimensionais evidenciaram a presença de 100% dos dentes com a classificação do Tipo I. Em relação à análise de canais acessórios foi possível observar alto índice de canais laterais, secundários e acessórios nos ICS, ILS e CS. Observou-se maior prevalência de curvatura leve nos ICS (45%) e moderada nos ILS (50%) e CS (50%). O volume do ombro palatino foi menor nos ILS (11,46 ± 3,09) quando comparado com os ICS (14,15 ± 3,85) e CS (13,95 ± 2,55). Na análise externa, observou-se maiores valores de comprimento nos CS (26,59 ± 1,93) e maiores dimensões da coroa nos ICS (10,46 ± 1,03). A maior prevalência da posição do forame foi na região central (22%), distopalatina (30%) e mesiovestibular (28%) para ICS, ILS e CS, respectivamente. A presença de sulcos radiculares foi de 2% nos ICS e 4% nos ILS. Desta forma, conclui-se que os dados bi e tridimensionais obtidos por meio da &mu;TC permitiram observar diferentes características morfológicas da anatomia interna e externa dos dentes anteriores superiores. / The study of the internal anatomy of the root canal system (RCS) is of paramount importance for the diagnosis, planning and endodontic treatment plan. The aim of this study was to evaluate the RCS anatomy of maxillary central and lateral incisors and canines by micro-computed tomography (&mu;CT). Fifty maxillary central incisors (MCI), 50 maxillary lateral incisors (MLI) and 50 maxillary canines (MC) scanned in the SkyScan 1174 &mu;CT device. The images were reconstructed for analysis of two-dimensional (number, area, roundness, form factor, major and minor diameter) at 1, 2, 3, 4 and 5 mm short of the apical foramen and three-dimensional parameters (volume, surface area, structure model index-SMI, number and localization of accessory canals, and localization and volume of palatal shoulder), as well as external anatomic characteristics of the teeth (length, crown dimensions, root curvature, foramen position, presence, position, depth and extent of radicular grooves) and for qualitative analysis of the internal anatomy of 3D models. The 2D analysis showed the presence of one canal in the apical third in the three dental groups. The roundness and form factor values revealed a circular canal in the apical third in the MCI and MC. In the MLI, these form descriptors indicated a circular form with tendency to flattening in the apical third. The linear regression test showed a progressive increase in the major and minor diameters in the 5 mm assessed (p <0.001), with respective increases of 0.09 mm and 0.07 mm for the MCI; 0.12 mm and 0.07 mm for MLI and 0.11 mm and 0.06 mm for MC. The 3D analysis revealed that the greatest means of volume (mm3) and surface area (mm2) were found in MCs. The SMI values were similar for the three dental groups, and suggested a tendency to a 3D cylinder-like geometry of the root canals. The analysis of 3D models showed that 100% of the teeth presented Vertuccis (1984) type I root canal configuration. Concerning the analysis of accessory canals was observed high rates of lateral, secondary and accessories canals in the MCI, MLI and MC. There was a prevalence of mild curvature in the MCI (45%) and moderate in the MLI (50%) and MC (50%). Palatal shoulder volume was smaller in the MLI (11,46 ± 3,09) than in the MCI (14,15 ± 3,85) and MC (13,95 ± 2,55). The external tooth analysis showed greater length values for MC (26,59 ± 1,93) and greater crown dimensions for MCI (10,46 ± 1,03). The prevalence of foramen position was the central (22%), distopalatal (30%) and mesiobuccal (28%) regions for MCI, MLI and MC, respectively. Presence of radicular grooves was observed in 2% of MCI and 4% of MLI. Thus, it may be concluded that the two and three-dimensional data obtained by &mu;CT allowed to observe different morphological characteristics of internal and external anatomy of the maxillary anterior teeth.
303

Monitorização e mensuração tomográfica de diferentes técnicas de crioterapia em pele de cães da raça Beagle, e sua relação com as medidas da necrose estimadas pela histopatologia / Computed tomography monitoring and mensuration of different cryotherapy techniques on the skin of Beagle dogs and their association with necrosis assessment through histopathological analysis

Lucas, Ronaldo 18 November 2004 (has links)
O uso do frio pela medicina é muito antigo, utilizado inicialmente de forma empírica, teve grandes avanços nos séculos XIV e XX, evoluindo juntamente com a Física. O surgimento de novas técnicas e equipamentos, possibilitou à crioterapia tornar-se uma importante opção no tratamento de neoplasias, benignas e malignas, de diferentes órgãos (tais como fígado, próstata, pâncreas e mamas) e sistemas (ósseo, neurológico e tegumentar). O grande desenvolvimento tecnológico permitiu além do maior número de indicações, melhores resultados, mormente com o uso de técnicas de imagem para o acompanhamento do procedimento. Porém, poucos são os trabalhos que enfocam a monitorização e mensuração do congelamento, pela tomografia computadorizada, bem como avaliação da necrose obtida. No presente trabalho propôs-se avaliar as relações entre as medidas obtidas pela tomografia computadorizada, em 20 cães da raça Beagle, durante o congelamento por aplicação do nitrogênio pela sonda fechada (75 segundos), spray (75 e 135 segundos) e derramamento (75 segundos), comparando estas medidas com aquelas mensuradas pela histopatologia da necrose provocada, para posteriormente avaliar a efetividade dos métodos e criar protocolos de tratamento. Os valores de diâmetro, raio, profundidade e volume do congelamento foram comparados entre si e, com os respectivos valores da necrose após 96 horas do procedimento. Os valores foram submetidos a análise de variância de medidas repetidas e teste de Bonferroni (p<0,05). Constatou-se que: a técnica de sonda fechada oferece congelamento e subseqüente necrose mais superficial que os outros métodos, sendo a técnica menos efetiva; em todas as técnicas o volume, diâmetro e profundidade são inferiores no tecido necrosado quando comparados aos seus similares naquele congelado; em nenhuma das quatro técnicas a profundidade de congelamento foi equivalente ao seu raio. Finalmente, houve a possibilidade de desenvolvimento de protocolos alternativos de congelamento a partir da profundidade de necrose pretendida (hf), obtendo-se como resultado (sonda - Di = hf / 0,29; spray I; Di = hf / 0,31; spray II - Di = hf / 0,35; derramamento -Di = hf / 0,38) o diâmetro do congelamento (Di) necessário para o êxito do tratamento / The use of cold by Medicine is a very old practice, initially used empirically, which had significant advances in the XIV and XX centuries, developing along with Physics. The appearance of new techniques and equipment turned cryotherapy into an important option in the treatment of benign and malignant neoplasms in different organs (such as the liver, the prostate, the pancreas and breasts) and systems (bone, neurological and tegumentary). The large technological development resulted in a higher number of indications as well as better results, especially with the concomitant use of imaging techniques to follow the procedure. However, few studies focus on the monitoring and mensuration of freezing through computed tomography, as well as the assessment of the resulting necrosis. Our study aims at evaluating the association between the measurements obtained through computed tomography in 20 Beagle dogs during freezing by liquid nitrogen use through a probe (75 sec), spray (75 and 135 sec) and overflow (75 sec), comparing these measurements to those obtained through histopathological analysis of the resulting necrosis, for later evaluation of the effectiveness of the methods and design of better treatment protocols. The values of diameter, radius, depth and volume of freezing were compared among them and also with the respective necrosis values 96 hours after the procedure. The values were submitted to analysis of variance of repeated measurements and Bonferroni test (p<0.05). We observed that the closed probe technique causes a more superficial freezing and resulting necrosis when compared to the other methods, being the less effective technique. In all techniques, the volume, diameter and depth are lower in the necrotic tissue when compared to those in the frozen tissue; none of the four techniques showed that freezing depth was equivalent to its radius. Finally, alternative freezing protocols could be developed from the depth of the intended necrosis (hf), resulting in the freezing diameter (Di) (probe - Di = hf/0.29; spray I; Di = hf/0.31; spray II Di = hf/0.35; overflow Di = hf/0.38), which is necessary for therapy success
304

Ultrassom de alta frequência para avaliação da tábua óssea vestibular de implantes dentais / High frequency ultrasound for evaluation of buccal bone surrounding dental implants

Bohner, Lauren Oliveira Lima 25 July 2017 (has links)
Objetivo: Avaliar a exatidão do ultrassom de alta frequência na mensuração das dimensões lineares tanto da tábua óssea vestibular como de defeitos periimplantares circundando implantes dentais. Materiais e Métodos: Em uma primeira etapa, implantes dentais (n=10) foram instalados na maxila de 3 crânios secos e escaneados com ultrassom de alta frequência (UAF) e tomografia computadorizada de feixe cônico (TCFC). As seguintes medidas lineares foram determinadas para avaliação: A) espessura óssea; B) nível ósseo. As medições foram comparadas com valores de referência determinados pela microscopia óptica. A segunda etapa do experimento envolveu amostras de osso porcino contendo defeitos ósseos ao redor dos implantes dentais (n=10), as quais foram escaneadas com ultrassom de alta frequência e tomografia computadorizada de feixe cônico. As seguintes medidas foram realizadas nos defeitos periimplantares: A) componente supra-alveolar, B) componente intra-ósseo e C) espessura do defeito. Os valores de referência foram determinado pela microtomografia computadorizada e o erro de medição (diferença entre grupo teste e controle) foi determinado. Os dados foram analisados estatisticamente considerando um nível de significância de p<=0.05. Resultados: Não houve diferença estatisticamente significante entre os grupos para as medições da espessura óssea e nível ósseo (p>0.05). Em relação à espessura óssea, a discrepância foi de 0.17mm para o UAF e 0.02mm para a TCFC. Para o nível ósseo, a discrepância foi de 0.55mm para o UAF e 0.12mm para a TCFC. Ao considerar o erro de medição dos equipamentos na mensuração de defeitos periimplantares, não houve diferença estatisticamente significante entre o UAF e TCFC (UAF= 0.54±0.69mm; TCFC= 0.62±0.55mm). Conclusão: O ultrassom de alta frequência apresentou exatidão para a mensuração das dimensões lineares da tábua óssea vestibular e de defeitos periimplantares circundando implantes dentais. / Purpose: To evaluate the accuracy of a high frequency ultrasound scanner (HFU) to the measurement of buccal bone and periimplant defects surrounding dental implants. Materials and Methods: The first phase of this study comprised the installation of dental implants (n=10) in the maxillary of 3 dry skulls. The dental implants were scanned with a high frequency ultrasound scanner and a cone-beam computed tomography (CBCT). The following measurements were determined for evaluation: A) bone thickness, and B) bone level. The measurements were compared with reference values determined by an optical microscopy. The second phase comprised the installation of dental implants (n=10) in porcine bone samples containing bone defects surrounding dental implants. The bone samples were scanned with a high frequency ultrasound and cone-beam computed tomography and the following measurements were performed: A) supra-alveolar component, B) intra-bony component and C) thickness. The reference values were determined by a micro-computed tomography and the measurement error (difference between experimental and control group) was determined for each group. All measurements were statistically analyzed with a significance level of p<=0.05. Results: There was no statistically significant difference between ultrasound and cone-beam computed tomography for the measurement of buccal bone (p>0.05). With regard to the bone thickness, the discrepancy to the reference values was 0.17mm for HFU and 0.02mm for CBCT. For bone level, the discrepancy was 0.55mm for HFU and 0.12mm for CBCT. The measurement error from both the devices not differed statistically (HFU= 0.54±0.69mm; CBCT= 0.62±0.55mm). Conclusion: The high frequency ultrasound presented accuracy for the measurement of buccal bone and periimplant defects surrounding dental implants.
305

Avaliação radiográfica e tomográfica do segmento lombo-sacro da coluna vertebral em cães da raça Pastor Alemão: estudo comparativo / Radiographic and tomographic evaluation of the lumbosacral junction in German Sheperd dogs: comparative study

Silva, Thelma Regina Cintra da 30 July 2008 (has links)
O nome síndrome da cauda eqüina define as manifestações clínicas oriundas da disfunção sensorial e/ou motora causada pela lesão das raízes nervosas que formam a porção terminal da medula espinhal. É uma condição neurológica resultante da compressão, destruição ou deslocamento dos trajetos nervosos que constituem a cauda eqüina. Acomete freqüentemente os cães de raças de grande porte, como Labrador, Golden Retriever, Bernese Mountain dog, Rottweiler e Pastor Alemão, não possuindo predileção quanto ao sexo e idade. As causas são inúmeras, podendo estar relacionada a fatores adquiridos, mais comuns nas raças de grande porte; ou congênitos, os quais são mais freqüentes nas raças de pequeno porte. Em ambos os casos, a estenose lombo-sacra é a causa mais comum, correlacionando-se às alterações das partes moles e/ou tecidos ósseos no segmento lombo-sacro. Este estudo teve por objetivo realizar uma análise crítica da contribuição dos métodos de imagem, quais sejam exames: radiográfico simples e tomográfico, para avaliação do segmento lombo-sacro em 30 cães da raça Pastor Alemão. Sendo treze animais pertencentes ao grupo (A) sem manifestações clínicas e alterações radiográficas no segmento lombo-sacra; doze animais pertencentes ao grupo (B) sem manifestações clínicas com alterações radiográficas no segmento lombo-sacro e cinco animais pertencentes ao grupo (C) com manifestações clínicas e portadores de alterações radiográficas no segmento lombo-sacro. Todos os exames foram submetidos a um protocolo de avaliação tendo como principais mensurações radiográficas: ângulo lombo-sacro, ângulo formado entre as epífises de L7-S1, ângulo dos processos articulares de L7-S1, listese ventral de S1 em relação à L7, grau de intersecção do vértice dos ângulos mensurados e grau de movimento na região lombo-sacra. O deslocamento ventral de S1 em relação à L7 esteve presente na maioria dos animais nos três diferentes grupos não só na dorso-extensão, levantando a hipótese de no padrão racial estudado, certo grau de listese possa fazer parte do esperado para o segmento lombo-sacro. Foi constatado diferença estatística entre os animais, nos seguintes grupos e variáveis: ângulo formado entre as epífises de L7-S1 (grupo A e B), grau de intersecção do ângulo entre as epífises de L7-S1 (grupo A e B), ângulo lombo-sacro (grupo A e B) e grau de movimento no segmento lombo-sacro (grupo A e B, A e C). Desta maneira, o grau de movimento demonstrou-se como elemento relevante no critério de avaliação do segmento lombo-sacro. O exame tomográfico mostrou-se superior na avaliação do canal vertebral, foramens intervertebrais e processos articulares, os quais puderam ser avaliados com maior riqueza de detalhes. Concluiu-se com esta pesquisa que as duas modalidades de imagem se complementam, constituindo ferramentas importantes na avaliação clínico-cirúrgica do segmento lombo-sacro, auxiliando no diagnóstico, estabelecimento do prognóstico e da terapêutica a ser adotada. / The name cauda equina syndrome defines the clinical signs that come from the sensory and or motor neural dysfunction caused by the terminal part of the spinal cord and adjacent nerve roots damages. Its one neurological condition resulting from the compression, destruction and displacement of the nervous routes which form the cauda equina. This syndrome normally happens to large breed dogs like the Labrador retriever, Golden Retriever, Bernese mountain dog, Rottweiler and the German shepherd dogs, without preference of gender or age. There are countless causes, which can be related to acquired factors, more common in the large breed dogs; or congenital, which are more frequent in the small breed dogs. In both cases, the stenosis lumbosacral is the most frequent, correlating to the alterations of the soft tissues and/ or the bone tissues in the lumbosacral segment. The aim of this sudy was to analise critically the real contribution of diagnostic imaging (X-Ray and CT), of the lumbosacral region of 30 German shepherd dogs. There were thirteen animals that belonged to the group (A) without clinical signs and X-Ray alterations in the lumbosacral segment; twelve animals belonged to the group (B) without clinical signs, with X-Ray alterations in the lumbosacral segment; five animals belonged to the group (C) with clinical signs and they had X-Ray alterations in the lumbosacral segment. All exams were submitted to one evaluation report which had as main radiographic measurements: lumbosacral angle, endplate angle L7 S1, articular process angle L7 S1 , ventral displacement of S1 to L7, the point of intersection of the measured angles and the mobility of the lumbosacral junction. The ventral displacement of S1 related to L7 was present in most of the animals in the three different groups not only in the extension position, raising the hypothesis about the racial standard established, a certain degree of ventral displacement of the sacrum might be part of the expected for the lumbosacral segment. It was noticed a statistical difference among the animals in the following groups and variables: endplate angle L7 S1 (groups A and B), the point of intersection of the endplate angle L7 S1 (groups A and B), lumbosacral angle (groups A and B) and the mobility of the lumbosacral junction (groups A and B, A and C). This way, the mobility showed itself as an relevant element in the criterion of evaluation of the lumbosacral segment. The CT examination showed being superior in the evaluation of the vertebral canal, intervertebral foramen and the articular processes, which could be evaluated with a greater number of details. It was concluded with this research that the two modalities of images complement each other, becoming important tools in the clinical- surgical evaluation in the lumbosacral segment, helping in the diagnosis, prognostic and therapeutic to be adopted.
306

Avaliação, por meio de microtomografia computadorizada, da anatomia interna de incisivos inferiores / Internal anatomy of lower incisors evaluated by computerized microtomography

Leoni, Graziela Bianchi 26 January 2012 (has links)
O conhecimento do sistema de canais radiculares (SCR) é de fundamental importância para o sucesso do tratamento endodôntico. O objetivo deste estudo foi avaliar quantitativa e qualitativamente a anatomia do SCR de incisivos inferiores por meio de microtomografia computadorizada. A aquisição de fotomicrotomografia de 283 incisivos centrais (ICI) e 329 incisivos laterais inferiores (ILI) foi realizada por meio do microtomógrafo SkyScan modelo 1174. Estas imagens foram utilizadas para classificação do SCR de acordo com Vertucci que considera número e localização da divisão dos canais, variando do tipo I ao VIII. Da amostra inicial, 39 ICI e 35 ILI foram escaneados com resolução de 22,9 &mu;m e reconstruídos para análises bidimensionais de: número, área, circularidade, diâmetro maior e menor a 1, 2, 3, 4 e 5 mm do forame apical; e análise tridimensional onde foram observados volume e área de superfície, número e localização de canais acessórios e classificação de acordo com Vertucci. Os resultados evidenciaram que, no terço apical, o número máximo de canais encontrados foi 3; a área aumentou progressivamente a cada milímetro avaliado; a circularidade variou entre 0,37 ± 0,21 (mínimo) e 0,52 ± 0,19 (máximo) demonstrando uma forma achatada destes canais; o diâmetro maior aumentou 95,45% nos ICI e 135,55% nos ILI enquanto o diâmetro menor aumentou 36,36% nos ICI e 66,67% nos ILI. A análise tridimensional revelou que em 76,92% dos ICI e 85,71% dos ILI foi possível a classificação de acordo Vertucci, com maior predominância do tipo I, com canal único, em 46,15% dos ICI e 54,29% dos ILI. Em 15,39% dos ICI e 11,43% de ILI foram identificadas dez novas morfologias. A média do volume (mm3) e da área de superfície (mm2) foram, respectivamente, de 4,38 ± 1,97 e 35,59 ± 11,72 para os ICI e 4,74 ± 1,33 e 38,91 ± 9,56 para os ILI. Os canais acessórios foram observados apenas no terço apical em 46,15% dos ICI e 28,57% dos ILI. Conclui-se que a microtomografia é um método não destrutivo, reprodutível e confiável para estudo de anatomia interna, sendo identificados dez novos tipos morfológicos de SCR de incisivos inferiores. / The knowledge of the root canal system (RCS) is of utmost importance to achieve success in the root canal treatment. The purpose of this study was to evaluate qualitative and quantitatively the RCS anatomy of mandibular incisors by means of microcomputed tomography. The image acquisition of 283 mandibular central incisors (MCI) and 329 mandibular lateral incisors (MLI) was performed using the SkyScan 1174 microtomography device. These images were used to classify the RCS from type I to VIII, considering the number and location of the canals, according to Vertuccis classification. From this sample, thirty-nine MCI and thirty-five MLI were scanned with a resolution of 22.9 &mu;m and reconstructed in order to evaluate the number and location of the main and accessory canals, according to Vertucci\'s classification, the bidimensional parameters of area, roundness, major and minor diameters of the root canal at 1, 2, 3, 4 and 5 mm from the apical foramen, as well as the three-dimensional analysis of volume and surface area. In the apical third, it was found up to three root canals; the area progressively increased from the apical foramen; the roundness ranged from 0.37 ± 0.21 to 0.52 ± 0.19 demonstrating the flat-oval shape of the canals; the major and minor diameters increased 95.45% and 36.36% in the MCI and 135.55% and 66.67% in the MLI, respectively. The threedimensional analysis revealed that in 76.92% of MCI and 85.71% of MLI the RCS could be classified according to Vertucci\'s, and type I (one root canal) was found in 46.15% and 54.29% of MCI and MLI, respectively. Ten new types of root canal morphologies were observed in 15.39% of MCI and 11.43% of MLI. The mean volume (mm3) and surface area (mm2) were 4.38 ± 1.97 and 35.59 ± 11.72 in the MCI, and 4.74 ± 1.33 and 38.91 ± 9.56 in the MLI, respectively. Accessory canals were observed only in the apical third in 46.15% of MCI and 28.57% of MLI. It was concluded that the microtomography is a non-destructive, reproducible and reliable method for the study of the RCS that allowed the identification of ten new types of root canal morphologies in mandibular incisors.
307

Avaliação de realce tardio pela Tomografia Computadorizada em pacientes chagásicos crônicos com disfunção ventricular / Delayed enhanced computed tomography in chronic chagasic patients with ventricular dysfunction

Silva, Nackle Jibran 26 June 2014 (has links)
A Doença de Chagas é uma infecção parasitária causada pelo Trypanosoma cruzi1, transmitida aos humanos principalmente pelas fezes contaminadas de insetos triatomídio. Esta patologia permanece endêmica na América Latina com grande impacto socioeconômico. O envolvimento cardíaco é a principal causa de morte, sendo que a fisiopatologia e a evolução clínica da doença não são completamente compreendidas e a estratificação de risco permanece desafiadora. A presença de disfunção miocárdica associada ou não à doença arterial aterosclerótica vem acompanhada de áreas de fibrose miocárdica e tem se mostrado como importante fator de pior prognóstico. Ressonância Magnética (RM) é um método já consagrado na detecção de fibrose miocárdica pela técnica de realce tardio (RT). Os objetivos deste trabalho foram: identificar e quantificar a área de realce tardio em pacientes com Cardiopatia Chagásica e disfunção contrátil do ventrículo esquerdo por meio da Tomografia Coronária; associar a extensão do RT pela tomografia com a FE do ventrículo esquerdo, medida pela ecocardiografia; determinar se há ou não associação da presença e extensão do realce tardio com a presença de coronariopatia significativa; determinar a presença de aterosclerose coronária neste subgrupo de pacientes chagásicos por meio do escore de cálcio; e identificar a presença de coronariopatia obstrutiva nesta população. Foram selecionados 36 pacientes com o diagnóstico confirmado de Doença de Chagas e disfunção ventricular (FE< 50%) confirmada pela ecocardiografia que respeitaram os critérios de inclusão e exclusão, e que assinaram o termo de consentimento livre e esclarecido. Todos os pacientes foram submetidos a angiotomografia coronária com a técnica de realce tardio e escore de cálcio. Todos os pacientes completaram o protocolo sem efeitos adversos com dose de radiação média de 11,17 +- 1,26 mSv e com exames interpretáveis. Observadores cegos e independentes, sem conhecimento prévio dos dados clínicos ou dos exames, realizaram análise visual e quantitativa do grau de estenose coronária, do escore de cálcio e do realce tardio. A média da idade foi de 57,5+- 8, dos quais 61,1% eram mulheres. A média da FE foi de 38,19 +- 6,91. Foram encontradas 2 lesões significativas (>50%) em 2 pacientes. A média do escore de cálcio foi de 19,06 +- 40,72. A fibrose miocárdica foi observada em 86,1% dos 36 pacientes e sua quantificação foi realizada de acordo com o esquema de segmentação miocárdica segundo a orientação da American Hear Association. A partir dos nossos achados, concluímos que, por meio da Tomografia coronária, é possível identificar áreas de fibrose miocárdica em pacientes chagásicos, que a quantidade de fibrose é inversamente proporcional à fração de ejeção ventricular esquerda (r= 0,52 p = 0,0011) e que a fibrose segue um padrão de localização específico da doença. Nossos achados permitem também inferir que a fibrose miocárdica nesse grupo de pacientes não se correlaciona à presença de obstruções coronárias, sendo o padrão de realce tardio diferente daquele observado em portadores de doença arterial coronária. Não houve correlação entre o escore de cálcio e áreas de fibrose vistas pela técnica de realce tardio (r= 0,04 p= 0,80). Desta forma, a tomografia pode ser uma alternativa à RM para a pesquisa de fibrose em pacientes chagásicos, aspecto que pode ser particularmente relevante naqueles que apresentam contraindicação formal à realização deste exame. / Chagas disease is a parasitic infection caused by Trypanosoma cruzi1. It is transmitted to humans mainly by the infected feces of triatomine insects. This pathological condition remains endemic in Latin America, posing a major socioeconomic impact on the region. Cardiac involvement is the principal cause of death of patients, given that the physiopathological mechanism and clinical evolution of the disease are not fully understood and risk stratification remains a challenge. Whether associated with arteriosclerotic vascular disease or not, the presence of myocardial dysfunction is accompanied by areas of myocardial fibrosis and has emerged as an important factor associated with poor prognosis. Magnetic resonance (MR) imaging is a well-established method of detecting myocardial fibrosis by the delayed enhancement (DE) technique. Objectives: The objectives of this thesis are to identify and quantify DE areas on left ventricular contractile dysfunction patients with chagasic cardiopathy using coronary tomography, to associate tomography DE extension with left ventricular ejection fraction (EF) measured by echocardiography, to determine whether the presence and extension of DE are associated with the presence of significant coronaropathy, and to identify the presence of obstructive coronaropathy in chagasic patients. Background: Methods: Thirty six patients with confirmed Chagas disease and ventricular dysfunction diagnosis (EF < 50%), as verified by echocardiography. All the patients underwent coronary computed tomographic (CT) angiography using DE technic. All the patients successfully completed the protocol with a mean radiation dose of 11.17 1.26 mSv, without adverse effects and undergoing measurable tests. Independent observers blinded to the clinical data or examinations of the patients performed visual and quantitative analyses of the degree of coronary stenosis, and DE. Results: The mean age was 57.5 8 years, and 61.1% of them were female. The mean EF was 38.19 6.91%. Two significant lesions (>50%) were identified in two patients. Myocardial fibrosis was observed in 86.1% of the 36 patients, and its quantification was assessed in accordance with the myocardial segmentation scheme and the American Heart Association guidelines The amount of fibrosis is inversely proportional to left ventricular EF (r = 0.52, p = 0.0011), and that the myocardial fibrosis in these patients follows the specific localization pattern of Chagas disease. Our findings reveal that myocardial fibrosis in this patient sub group was not related to coronary obstruction and that the DE pattern is different from the one found in patients who presented ischemic events. Computed tomography DE is also inversely related to left ventricle ejection fraction, another important prognosis marker. Therefore, computed tomography can provide an adequate alternative to MR in the assessment of myocardial fibrosis particularly in patients presenting formal contraindications to MR.
308

Desenvolvimento de um Guia orientativo para dosimetria em Tomografia Computadorizada / Development of a guidance guide for dosimetry in computed tomography

Fontes, Ladyjane Pereira 19 October 2016 (has links)
Devido as frequentes dúvidas dos usuários das câmaras de ionização do tipo lápis calibradas no Laboratório de Calibração de Instrumentos do IPEN (LCI IPEN), em como aplicar corretamente os fatores indicados em seus certificados de calibração, foi elaborado um guia orientativo para dosimetria em tomografia computadorizada. O guia orientativo inclui o conhecimento prévio da Camada Semirredutora (CSR), já que é necessário conhecer a energia efetiva do feixe para aplicação do fator de correção para qualidade (kq). A avaliação da CSR em tomógrafos torna-se uma difícil tarefa devido à geometria do sistema e por essa razão foi realizado um levantamento das metodologias existentes para a determinação da CSR em feixes clínicos de Tomografia Computadorizada (TC), levando em consideração fatores técnicos, práticos e econômicos. Neste trabalho, optou-se em testar um Sistema Tandem composto por capas absorvedoras confeccionado na oficina do IPEN, baseado em estudos preliminares devido ao baixo custo e boa reposta. O Sistema Tandem é composto por 5 capas absorvedoras cilíndricas de 1 mm, 3 mm, 5 mm, 7 mm, e 10 mm de alumínio e por 3 capas absorvedoras cilíndricas de 15 mm, 25 mm e 35 mm de acrílico (PMMA) acopladas à câmara de ionização do tipo lápis comercial amplamente utilizada em testes de controle de qualidade na dosimetria em feixes clínicos de Tomografia Computadorizada. Através das curvas Tandem, foi possível avaliar os valores de CSR e, através da curva de calibração da câmara de ionização do tipo lápis, encontrar o Kq adequado ao feixe. O Guia elaborado traz informações de como construir a curva de calibração em função da CSR, para encontrar o Kq, bem como informações para construção da curva Tandem, para encontrar valores próximos de CSR. / Due to frequent questions from users of ionization chambers pencil type calibrated in the Instrument Calibration Laboratory of the Institute of Energy and Nuclear Research (LCI - IPEN), on how to properly apply the factors indicated in their calibration certificates, a guide was prepared guidance for dosimetry in computed tomography. The guide includes guidance prior knowledge of half value layer (HVL), as it is necessary to know the effective beam energy for application quality for correction factor (kq). The evaluation of HVL in TC scanners becomes a difficult task due to system geometry and therefore a survey was conducted of existing methodologies for the determination of HVL in clinical beams Computed Tomography, taking into account technical, practical and economic factors. In this work it was decided to test a Tandem System consists of absorbing covers made in the workshop of IPEN, based on preliminary studies due to low cost and good response. The Tandem system consists of five cylindrical absorbing layers of 1mm, 3mm, 5mm, 7mm and 10mm aluminum and 3 cylindrical absorbing covers 15mm, 25mm and acrylic 35mm (PMMA) coupled to the ionization chamber of commercial pencil type widely used in quality control tests in dosimetry in clinical beams Computed tomography. Through Tandem curves it was possible to assess HVL values and from the standard curve pencil-type ionization chamber, Kq find the appropriate beam. The elaborate Guide provides information on how to build the calibration curve on the basis of CSR, to find the Kq and information for construction Tandem curve, to find values close to CSR.
309

Estudo imaginológico da regeneração óssea guiada associada ou não à terapia de fotobiomodulação (PBMT) em ratas com osteoporose / Imaging study of guided bone regeneration associated or not with photobiomodulation therapy (PBMT) in rats with osteoporosis

Alves, Fernando Amorim Mendonça 14 September 2018 (has links)
A osteoporose é uma doença sistêmica caracterizada pela perda de conteúdo mineral do osso propiciando fraturas críticas. A regeneração óssea guiada e a terapia de fotobiomodulação (PBMT do inglês photobiomodulation therapy) favorecem a regeneração óssea. O objetivo do estudo foi avaliar o efeito da PBMT no reparação óssea guiada de lesões críticas de 36 ratas com osteoporose induzida por ooforectomia. Foram realizadas lesões ósseas estandardizadas nos ossos parietais e então tratadas de acordo com os seguintes grupos experimentais (n=12 lesões por grupo): Controle: sem tratamento adicional; Membrana - Colocação de uma membrana de colágeno suíno comercial (Bio-Gide®) dentro do leito cirúrgico; PBMT1- membrana e aplicação da PBMT1; PBMT2- membrana e aplicação da PBMT2. A PBMT foi realizada com laser de diodo infravermelho no modo contínuo, pontual e em contato (808nm, 40mW, 1,42W/cm2; PBMT1: 3s, 4J/cm2, 0,12J por ponto e PBMT2: 10s, 14J/cm2, 0,4J por ponto) imediatamente, 48 e 96 horas após a cirurgia. Quatro e oito semanas após a cirurgia os animais foram eutanasiados, a calota craniana dissecada, fixada e submetida à análise por microtomografia computadorizada. Foram coletados os seguintes dados: volume ósseo relativo (razão entre o volume ósseo e o volume total), número, espessura e separação de trabéculas, conectividade por densidade e índice de estrutura de modelo (SMI do inglês structure model index). Os dados de cada análise foram comparados pelo teste ANOVA dois critérios/Tukey ou Kruskal Wallis/Dunn e os dados de análises diferentes pelo teste de correlação de Spearman (p<0,05). Diferenças significativas foram observadas em 8 semanas. A PBMT, em especial nos parâmetros de menor energia (0,12J), acelerou o reparo ósseo resultando na obtenção de maior volume ósseo, com grande número de trabéculas, de espessura média, próximas e interconectadas e com valores baixos de SMI. Dentro das limitações deste trabalho in vivo, concluímos que a PBMT acelera a formação e maturação do tecido ósseo neoformado em lesões ósseas críticas de ratas osteoporóticas. / Osteoporosis is a systemic disease characterized by loss of bone mineral content leading to critical fractures. Guided bone regeneration and photobiomodulation therapy (PBMT) favor bone regeneration. The objective of the study was to evaluate the effect of PBMT on the guided bone repair of critical lesions of 36 rats with osteoporosis induced by oophorectomy. Standardized bone lesions were performed on the parietal bones and then treated according to the following experimental groups (n = 12 lesions per group): Control: no additional treatment; Membrane - Placement of a commercial swine collagen membrane (Bio-Gide®) within the surgical bed; PBMT1 membrane and PBMT1 application; PBMT2-membrane and PBMT2 application. PBMT was performed with continuous wave infrared diode lasers in punctual and contact mode (808nm, 40mW, 1.42W / cm2, PBMT1: 3s, 4J / cm2, 0,12J per ponit and PBMT2: 10s, 14J / cm2, 0.4J per point) immediately, 48 and 96 hours after surgery. Four and eight weeks after surgery, the animals were euthanized, the skulls dissected, fixed and submitted to the analysis by computerized microtomography. The following data were collected: bone volume, relative bone volume (ratio of bone volume to total volume), number, thickness and separation of trabeculae, density connectivity and model structure index (SMI). The data from each analysis were compared using the ANOVA two criteria / Tukey or Kruskal Wallis / Dunn test and the different analysis data by the Spearman correlation test (p <0.05). Significant differences were observed at 8 weeks. PBMT, especially in the lower energy parameters (0.12J), accelerated bone repair resulting in higher bone volume, with a large number of trabeculae, medium thickness, close to each other and interconnected, and with low SMI values. Within the limitations of this in vivo study, we concluded that PBMT accelerates the formation and maturation of neoformed bone tissue in critical bone lesions of osteoporotic rats.
310

Avaliação de desvio do septo nasal em imagens panorâmicas e tomográficas volumétricas / Study on nasal septum deviation in panoramic and computerized tomography images

Zanda, Marcelo Junior 28 August 2009 (has links)
Neste estudo avaliou-se a eficácia da radiografia panorâmica na detecção de desvio do septo nasal. Para tanto, utilizou-se como padrão ouro o exame clínico e imagens tomográficas da face. A amostra foi composta por imagens radiográficas panorâmicas e por imagens de tomografia computadorizada da face de 70 indivíduos. Dentre os indivíduos que compuseram o estudo, 30 eram pacientes que seriam submetidos a tratamento odontológico e possuíam radiografias panorâmicas nas quais foram observadas imagens compatíveis com desvio do septo nasal. Estes pacientes foram avaliados por um otorrinolaringologista e submetidos, segundo o critério da justificação, ao exame de tomografia computadorizada da face. Os outros 40 indivíduos foram selecionados a partir de imagens panorâmicas dos prontuários de pacientes disponíveis no arquivo da Clínica de Estomatologia da FOB-USP e que também haviam realizado tomografia computadorizada da face para elaboração de diagnóstico e plano de tratamento odontológico. Os resultados mostraram que a radiografia panorâmica, segundo a metodologia adotada, foi eficaz na detecção do desvio do septo nasal, com 100% de Especificidade. Além disso, este exame permite a confirmação da ausência deste desvio na maioria dos casos, com 86% de Sensibilidade. / OBJECTIVE: Discern the efficacy of panoramic radiography on nasal septum deviation. Gold standard computerized tomography along with clinical examination was used for comparison. MATERIAL AND METHODS: Sample was composed of 70 subjects from Stomatology files of FOB-USP. Nasal septum deviation was assessed using the panoramic radiographies. Then, computerized tomography was analyzed and the results confronted. RESULTS: Images of nasal septum deviation were observed and confirmed in both exams on 100% of the subjects. However, in those cases with no deviation observed with the panoramic radiographies, its presence was confirmed in 86% after computerized tomography. CONCLUSION: Panoramic radiography was trustable for confirmation of nasal septum presence, with 100% of Specificity. Further, this exam allows the confirmation of the absence of this deviation in the majority of cases, with 86% of Sensibility.

Page generated in 0.0677 seconds