• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1493
  • 30
  • 10
  • 8
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 4
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 1553
  • 1199
  • 895
  • 812
  • 377
  • 353
  • 342
  • 326
  • 311
  • 246
  • 207
  • 180
  • 162
  • 160
  • 158
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
321

Comparação do transporte, centralização e extrusão apical de detritos após o uso de sistemas de NiTi em canais radiculares curvos

Boijink, Daiana January 2018 (has links)
Introdução: Os objetivos do presente estudo foram comparar a extrusão apical de detritos durante o preparo apical #25 com os sistemas Twisted File Adaptive (TFA), WaveOne Gold (WOG) e técnica manual (TM), registrar o tempo de preparo; e comparar WOG com TFA em relação ao transporte do canal radicular (TCR) e centralização (CR) com diâmetros apicais #25 e #35. Metodologia: Quarenta e cinco canais mésio-vestibulares de molares inferiores foram preparados e divididos em 3 grupos (n=15) para avaliar extrusão apical. A extrusão de detritos foi quantificada subtraindo-se o peso final do peso inicial dos tubos Eppendorf. TCR e CR foram avaliados em micro-TC com os sistemas TFA e WOG (n=15). A normalidade dos valores obtidos para cada grupo foi verificada usando teste de Kolmogorov-Smirnov. Para quantificar detritos extruídos e tempo de preparo, os dados foram paramétricos, sendo utilizado o Teste ANOVA de 1 via e post hoc de Tukey’s. Para avaliar TCR e CR, o teste estatístico foi Mann Whitney e Wilcoxon (α=.05). Resultados: Em relação aos detritos, o sistema WOG foi associado com menos extrusão em comparação com TM (P<0,05) ou com o sistema TFA (P> 0,05). O tempo de preparo exigido pela TM foi significativamente maior do que o exigido pelas outras técnicas (P<0,05). Não foram encontradas diferenças estatisticamente significantes entre WOG e TFA em relação à centralização em todos os níveis, quando usado diâmetro apical #25 ou #35 (P> 0,05). Para TCR, diferença significativa foi encontrada entre TFA e WOG a 1 e 7mm com diâmetro apical #25 e #35 (P<0,05). Foi encontrada diferença significante para TFA em 4mm, quando os diâmetros apicais #25 e #35 foram avaliados no mesmo sistema (P <0,05). Conclusões: Todos os sistemas de instrumentação causaram extrusão de detritos apicais em algum grau. TFA e WOG podem ser usados em canais radiculares curvos com segurança com diâmetros apicais# 25 ou 35. / Introduction: The aims of this study were to assess the amount of apically debris during root canal preparation with apical size #25 with the Twisted File Adaptive system (TFA), WaveOne Gold system (WOG) and manual technique (MT), and recorded working time; and to assess WOG with TFA in relation to root canal transportation (RCT) and centering ratio (CR) with apical diameters # 25 and # 35. Methods: Forty-five mesiobuccal root canals of mandibular molars were prepared and assigned into 3 groups (n = 15) to evaluate apical extrusion. Debris extrusion was quantified by subtracting the final from the initial weight of the Eppendorf tubes. RCT and CR were evaluated in Micro-TC with the TFA and WOG systems (n = 15). The normality values obtained for each group were tested using the Kolmogorov-Smirnov test. To quantify extruded debris and preparation time, the data were parametric, using the Tukey's 1-way and post-hoc ANOVA test. To evaluate RCT and CR, the statistical test was Mann Whitney (α =.05). Results: The WaveOne Gold reciprocating single-file system was associated with less extrusion of debris compared with hand files (P < 0.05) or with the Twisted File Adaptive system (P > 0.05). The preparation time required by hand files was significantly longer than that required by the other techniques (P < 0.05). No significant differences were found between WOG and TFA regarding CR for all levels when used #25 or #35 apical size preparation (p>0.05). For RCT, significant difference was found among TFA and WOG at 1 mm and 7 mm with diameter apical #25 and #35. (p<0.05). Statistically different for the TFA in 4 mm was observed when the apical diameters # 25 and # 35 was evaluated in the same system (P <0,05). Conclusions: All of the instrumentation systems caused apical debris extrusion to some degrees. TFA and WOG can be used in curved root canals with safety with #25 or 35 apical diameters.
322

Paracoccidioidomicose tomografia computadorizada de alta resolução no estudo das alterações pleuro-pulmonares e mediastinais

Kauer, Carmen Lucia January 2000 (has links)
O estudo avalia as alterações pleuro-pulmonares e mediastinais detectáveis pela tomografia computadorizada de alta resolução na paracoccidioidomicose com comprometimento pulmonar em momentos distintos da evolução da doença: na fase ativa previamente ao tratamento medicamentoso específico ou até 30 dias do seu início, e na fase inativa, a partir do 6° mês (em média, 11,53 meses após). Foram acompanhados 37 pacientes (de 32 a 68 anos) com envolvimento pulmonar crônico por, em média, 29,60 ± 11,21 meses. No total, foram analisadas 60 tomografias, 28 na fase ativa da doença e 32 na fase inativa, sendo que 23 pacientes realizaram exames nas duas fases e 14 somente em uma delas. Utilizaram-se cortes axiais de 2mm, com intervalo de 10mm, no sentido crânio-caudal, em cuja reconstituição usou-se algoritmo de alta freqüência espacial. Os cortes foram fotografados em duas janelas de densidades apropriadas ao estudo do pulmão, parênquima pulmonar e mediastino (120 V; 2 s; 80 a 130 mA). Os achados mais freqüentemente detectados na fase ativa da doença foram: 1) espessamento de septos interlobulares (96,43%); 2) nódulos (92,86%); 3) consolidação (71,43%); 4) enfisema (67,86%); 5) espessamento de paredes brônquicas (64,29% ); 6) distorção da arquitetura broncovascular (60,71% ); 7)espessamento pleural (57,14%); 8) bolha (46,42 %); 9) bronquiectasias (42,86%); 10) linfonodomegalias (39,29%); 11) cavidades (35,71 %); 12) opacidade em vidro despolido (32,14%); 13) retração pleural (32,14%); 14) tree-in-bud (17,86%); 15) faveolamento e alterações fibróticas (14,29%). Em nenhum caso identificou-se pneumotórax espontâneo e/ ou derrame pleural. Em relação aos achados detectados no exame feito após o tratamento, verificou-se tendência 1) em manter a mesma quantidade de nódulos, com dimensões semelhantes, à detectada na fase ativa, mas com contornos bem-definidos mais freqüentemente; 2) em manter a presença de consolidação, mas em menos áreas; 3) em reduzir a presença e extensão de espessamento de paredes brônquicas; 4) em reduzir a quantidade de cavidades, sem alteração no seu diâmetro; 5) em reduzir a quantidade de bronquiectasias; 6) em reduzir a presença de linfonodomegalias; 7) em reduzir a quantidade de áreas com opacidade em vidro despolido; 8) em manter múltiplas áreas com espessamento de septos interlobulares. Predominaram as alterações de distribuição difusa, nos campos médios, bilaterais, nas regiões posteriores. Em três pacientes detectou-se bola fúngica na tomografia, sendo que em um identificou-se A.fumigatus no material obtido através da punção pulmonar transcutânea. A tomografia permite uma avaliação objetiva do tipo, extensão, distribuição, intensidade, localização e tamanho das alterações pleuro-pulmonares na paracoccidioidomicose, mas não identifica um achado ou característica que possa ser utilizado como critério para definir .doença ativa ou inativa. O estudo não detectou, no que se refere às variáveis analisadas, diferença estatísticamente significante (P Fischer • 1,00) entre as proporções iniciais encontradas na fase ativa da doença quando comparadas com as finais (fase inativa).
323

Avaliação da aeração e edema pulmonar por meio de tomografia computadorizada em pacientes submetidos a revascularização do miocárdio / Evaluation of the aeration and edema pulmonary by means of computed tomography in patients undergoing coronary artery bypass graft

Roseny dos Reis Rodrigues 30 August 2010 (has links)
Introdução: A disfunção respiratória é uma das complicações de maior prevalência no período pós-operatório de pacientes submetidos à cirurgia de revascularização do miocárdio (RM) com circulação extracorpórea (CEC), mesmo na ausência de doença pulmonar prévia1. Por meio de tomografia computadorizada, foram investigadas as alterações pulmonares pósoperatórias e o seu impacto na oxigenação. Métodos: vinte pacientes não hipoxêmicos em programação de cirurgia eletiva de revascularização do miocárdio com CEC foram estudados. Medidas hemodinâmicas, e amostras sanguíneas seriadas foram obtidas antes da cirurgia, após a intubação orotraqueal, após a CEC, na UTI, 12h, 24h e 48h após a cirurgia. Tomografias volumétricas pré e pós-operatórias foram adquiridas em condições de apneia após uma expiração espontânea. Os dados foram analisados usando teste de t Student; o comportamento temporal dos dados hemodinâmicos e outras variáveis fisiológicas foi analisado ao longo do tempo, usando análise de variância de uma via para repetidas medidas, seguido pelo teste de Student-Neumann-Keuls, quando necessário.Resultados: a relação PaO2/FiO2 diminuiu de forma significativa após a indução da anestesia, atingindo o seu nadir após a saída de CEC. Comparando-se com a TC pré-operatória, foi observada uma redução de 31% no volume de gás pulmonar (p<0,001), ao passo que foi observado um aumento do volume de tecido de 19% (p<0,001). A área não aerada dos pulmões aumentou de 253 97 g(p < 0.001), de 3 % a 27 %, após a cirurgia; e a área pobremente aerada pulmonar apresentou aumento de 72 68 g (p < 0.001), de 24 % to 27 %, enquanto a área normalmente aerada pulmonar reduziu de 147 119 g (p < 0.001), que representa 72 % to 46%. Não foram observadas correlações entre a relação PO2/FIO2 ou na fração de shunt nas primeiras 24 horas pós-operatórias Conclusões: A estrutura pulmonar está profundamente modificada após a cirurgia de RM com CEC. Associadas a outros fatores, essas alterações são responsáveis pela ocorrência de hipoxemia resultantes de atelectasias / Introduction: Hypoxemia is a frequent complication after coronary artery bypass graft (CABG) with cardiopulmonary bypass (CPB), usually attributed to atelectasis. Using computed tomography (CT), we investigated pulmonary alterations postoperatively and its impact on oxygenation. Methods: Twenty non-hypoxemic patients with normal cardiac function scheduled to CABG under CPB were studied. Hemodynamic measurements and blood samples were obtained before surgery, after intubation, after CPB, at ICU admission, 12h, 24h and 48h after surgery. Pre and postoperative volumetric thoracic CT scans were acquired in apnea conditions after a spontaneous expiration. Data was analyzed using paired Student t test and two-way repeated measures analysis of variance followed by SNK test when indicated. Results: PaO2/FiO2 ratio was significantly reduced after anesthesia induction, reaching its nadir after CPB and partially ameliorating 12h after surgery. Compared to preoperative CT, there was a postoperative 31 % reduction in pulmonary gas volume (p < 0.001) while tissue volume increased by 19 % (p < 0.001). Non-aerated lung increased by 253 97 g(p < 0.001), from 3 % to 27 %, after surgery and poorly-aerated lung by 72 68 g (p < 0.001), from 24 % to 27 % while normally-aerated lung was reduced by 147 119 g (p < 0.001), from 72 % to 46 %. No correlations were observed between PaO2/FiO2 ratio or shunt fraction at 24 h postoperatively and postoperative lung alterations. Conclusions: Lung structure is profoundly modified after CABG with CPB. Taken together, these multiple alterations occurring in the lungs are responsible for postoperative hypoxemia instead of atelectasis alone
324

Avaliação da estabilidade inicial de implantes instalados em modelos ósseos suínos padronizados em posicionamentos ao nível ou infraósseos / Evaluation of implants placed in bone standardized pig models in positions bone level or intraosseous using biomechanical tests and Micro-CT. An in vitro pilot study

Jessica Pires de Carvalho 25 August 2016 (has links)
A estabilidade primária é decorrente da adaptação mecânica imediata entre o osso e o implante após a sua inserção. O sucesso desta adaptação depende de fatores como a densidade e qualidade ósseas, tamanho, diâmetro, forma e rugosidade da superfície do implante. As cargas oclusais aplicadas sobre o implante podem afetar o osso circundante. Esse estudo teve como objetivo avaliar, comparativamente, a estabilidade inicial de implantes ósseo inseridos em cilindros de osso suíno padronizados, em diferentes posicionamentos ósseos, com e sem a aplicação de carga, por meio de análises de imagens tridimensionais (microtomografia computadorizada) e análises mecânicas (Frequência de ressonância, Torque de inserção e Ensaio de arrancamento). Os cilindros ósseos foram preparados a partir de osso suíno e separados em 2 grupos conforme a área doadora: Grupo A: cilindros removidos da cabeça do fêmur (alta densidade óssea) e Grupo B: cilindros removidos do côndilo mandibular (baixa densidade óssea). Previamente aos procedimentos experimentais, os cilindros ósseos foram certificados através de análises de imagens 2D (radiografia digital), para garantir a uniformidade intra-grupos e distinção entre os grupos dos espécimes. Após a certificação, foram feitas microtomografias computadorizadas dos cilindros ósseos para análise tridimensional de imagens prévia à instalação dos implantes, avaliando os seguintes parâmetros: porcentagem de volume ósseo (BV/TV), separação trabecular (TbSp), razão entre a medida da área superficial do osso e o seu volume ósseo (BS/BV) e porcentagem de porosidade total (POTOT). Depois disso, foram selecionados 60 implantes, que foram divididos em 4 grupos, cada um com 15 implantes: G1 (cilindros ósseos de alta densidade com implante situados ao nível ósseo), G2 (cilindros ósseos de alta densidade com implante 2 mm infraósseo), G3 (cilindros ósseos de baixa densidade com implante ao nível ósseo) e G4 (cilindros de baixa densidade com implante 2 mm infraósseo). A instalação dos implantes seguiu o protocolo recomendado pelo fabricante e durante o procedimento foi realizada a medida do torque de inserção. Após a instalação dos implantes, os cilindros ósseos foram submetidos à nova análise tridimensional (com avaliação dos mesmos parâmetros anteriores, nas áreas intra-roscas e adjacente à estas, acrescidos da medida da área de contato ossoimplante (BIC). Foi então realizada a avaliação do Coeficiente de Estabilidade (ISQ), utilizando a análise de frequência de ressonância (Osstell®). Após essa avaliação, 5 implantes de cada grupo foram submetidos ao ensaio de arrancamento. Os 10 implantes de cada grupo restantes foram conectados a pilares protéticos adequados, os quais receberam uma aplicação de forças axial (G1, G2, G3 e G4, 5 implantes de cada grupo) e lateral (G1, G2, G3 e G4, 5 implantes de cada grupo). Após aplicação das forças, os cilindros ósseos foram submetidos a nova análise tridimensional com avaliação dos mesmos parâmetros descritos, a nova análise de frequência de ressonância e ao ensaio de arrancamento. As variáveis foram testadas em relação à normalidade dos dados. Para todas as análises foi considerado um nível de significância de 5%. As análises estatísticas foram realizadas com base nos dados absolutos obtidos durante a análise tridimensional em cada situação de carga (antes do implante, pósimplante e pós-carga) e com a variação entre os valores das situações pós-implante e póscarga (variação carga - implante). A avaliação estatística do parâmetro de análise de frequência de ressonância não encontrou diferenças estatisticamente significantes para as comparações entre grupos G1 versus G3 e G2 versus G4 nas avaliações pós implante e pós carga. Em relação ao torque de inserção, houve diferenças estatisticamente significantes para as comparações entre grupos com implantes instalados no mesmo nível G1 versus G3 e G2 versus G4. Os maiores valores de torque de inserção obtidos foram registrados nos grupos de alta densidade. A análise estatística do ensaio de arrancamento mostrou diferenças estatisticamente significantes para as comparações: G1 versus G3 (inicial) e G1 versus G4 (inicial). Após a aplicação de carga oclusal, pode-se constatar diferenças estatisticamente significantes para as comparações: G1 versus G3 e G2 versus G4, após aplicação de carga lateral a análise mostrou diferença estatisticamente significante para a comparação G3 versus G4. Os resultados das análises tridimensionais mostraram diferenças estatisticamente significantes para os parâmetros TbSp e POTOT na avaliação da área óssea intra-rosca. A avaliação dos dados de variação após a aplicação de carga oclusal e lateral para o parâmetro TbSp, mostrou diferenças estatisticamente significantes para as comparações G2 versus G4. Em relação ao parâmetro POTOT, a aplicação de carga oclusal e lateral mostrou diferença estatisticamente significante para as análises: G1 versus G2 e G2 versus G4. Em relação ao parâmetro BSBV a análise dos valores absolutos, mostrou diferenças estatisticamente significantes para a área óssea intra-rosca dos grupos de baixa densidade. Já a análise dos valores de variação, a aplicação de carga oclusal mostrou diferenças estatisticamente significantes para os grupos G1 versus G3, G2 versus G4 e G3 versus G4, enquanto a aplicação de carga não axial resultou em diferenças estatisticamente significantes para os grupos G3 versus G4 e G2 versus G4. Já a análise estatística dos dados de variação do parâmetro BV/TV, mostrou diferença estatisticamente significante para todas as comparações na área óssea intra-rosca após aplicação de carga oclusal e lateral. A análise estatística do parâmetro BIC mostrou diferenças significantes para os grupos de baixa densidade (G3 e G4) nas comparações pós implante e pós carga. Em relação aos dados de variação, pode-se constatar diferença estatisticamente significante na aplicação de carga axial para G1 versus G2 e G2 versus G4, enquanto a aplicação de carga lateral mostrou diferença estatisticamente significante para as comparações G1 versus G3 e G2 versus G4. De acordo com os dados obtidos pode-se concluir que a densidade óssea tem relação com a estabilidade primária de implantes, que cargas não axias são prejudiciais para o tecido ósseo peri-implantar e que o posicionamento infraósseo pode promover melhor resposta do tecido ósseo, principalmente em regiões de baixa densidade óssea. / With the increase of oral rehabilitation with implants, immediate load can be used to reduce the treatment time. It is important to perform correct treatment planning for immediate implant loading, using 3D image analysis. The subcrestal implant positioning is one of the possible factors that may impact the success of immediate loading implants. Objective: The aim of this study is to evaluate the initial stability of osseointegrated implants placed infra bone or at the bone level in standardized porcine bone cylinders, through image (microcomputerized tomography) and mechanical analysis (resonance frequency, insertion torque and pull out test). Sixty bone cylinders were prepared from fresh porcine bone and separated in 2 groups: Group A 30 cylinders removed from femur head (high bone density) and Group B - 30 cylinders removed from the mandibular condyle (low bone density). Before the experimental procedure, the bone cylinders were certificated through 2D images analysis (digital radiography) to calculated bone density. After this, the bone cylinders were evaluated through micro computed three-dimensional analysis before the implant insertion. The parameters were analyzed in 2 levels (L1-bone volume internal to the threads and L2 - immediately adjacent to the end of threads). The microtomographical parameters analyzed were: Bone volume/Total volume (BV/TV), Trabecular thickness (TbSp), Bone surface/Volume ratio (BS/BV) and Total porosity percent (POTOT). Then, 60 implants (Alvim, 3.5 mm x 10 mm, Neodent®, Curitiba) were inserted in bone cylinders (1 implant in each cylinder), according to manufacturers protocol, and insertion torque was recorded for each implant. After that, the bone cylinders were submitted a new micro computed tomography analysis that evaluated the same levels and parameters, and Bone Implant Contact (BIC) was also recorded. After that, 5 implants were submitted to pull out test while the others implants received axial and non- axial load. After that, a new microcomputerized tomography analysis evaluated the same levels and parameters previously described, and resonance frequency analysis and pullout test were performed in the bone cylinders. 3D analysis showed that pre- and post-implants intra-groups had statistically significant differences for TbSp and POTOT parameters, and for BSBV and BIC parameters there were observed statistically significant differences for low bone densities groups. The values of differences between post and before loading showed statistically significant differences between G2 and G4 for TbSp, POTOT, BSBV, BV/TV and BIC parameters. The RFA analysis showed highest values for G2 and G4. Concerning insertion torque, the highest mean values were found in high bone densities groups. The pullout strength test showed that the non- axial loads in the low bone density maybe lead to implant displacement throughout the implant insertion axis. Bone density has a direct relationship with implant primary stability. Non- axial loads are harmful to peri- implantar bone tissue and subcrestal placement of implants presented the best mechanical and tomographical results.
325

Efeitos do colimador na qualidade de imagem em tomografia industrial de terceira geração / Collimator effects on image quality in industrial tomography third generation

Diego Vergaças de Sousa Carvalho 08 May 2014 (has links)
O estudo do efeito da colimação nos detectores de radiação sobre a qualidade de imagem do tomógrafo industrial de terceira geração desenvolvido no IPEN/CNEN-SP é descrito neste trabalho. Três conjuntos de colimadores de chumbo foram projetados e confeccionados, sendo um com janelas retangulares de 2 x 5 x 50 mm e outro com 4 x 10 x 50 mm (largura x comprimento x profundidade) e um terceiro com orifício circular de 5 mm de diâmetro x 40 mm de profundidade. Os colimadores foram projetados para poderem ser facilmente substituídos entre si nos detectores de radiação. Paralelamente, foram confeccionados e utilizadas a eletrônica associada, constituída de analisadores de sinais tipo multicanal de 8 bits contendo a unidade de alta tensão e o amplificador. Dentre as vantagens deste sistema destaca-se a sua capacidade de análise multicanal rápida e possuir uma eletrônica mais simples. Valores de resolução energética comparável com a da literatura foram encontrados utilizando a eletrônica desenvolvida acoplada ao detector de radiação de NaI(Tl). Os efeitos dos colimadores foram avaliados pelas medidas tomográficas em um fantom de polimetilmetacrilato contendo componentes multifásicos estáticos (ferro, alumínio e ar). Fontes de radiação com energias de das fontes de 75Se (97 keV, 121 keV, 136 keV, 265 keV, 279 keV e 400 keV), de 137Cs (662 keV) e de 192Ir (317 keV, 468 keV e 602 keV) observou-se que a melhor imagem do fantom foi obtida com os colimadores de janelas retangulares (fendas) de 2 x 5 x 50 mm. Na avaliação dinâmica da formação de bolhas em coluna simuladora de processos industriais, a melhor imagem foi obtida com a fonte de 192Ir. / The study of the effect of collimation in radiation detectors on the image quality of the third-generation industrial CT scanner developed at IPEN / CNEN-SP is described in this work. Three sets of lead collimators were designed and manufactured, one with rectangular windows of 2 x 5 x 50 mm and the other with 4 x 10 x 50 mm (width x length x deep) and a third circular hole of 5 mm diameter x 40 mm deep. The collimators were designed to be easily interchanged in radiation detectors. In parallel, were prepared and used the associated electronics, consisting of multi-channel signal analyzers type of 8 bits containing the high voltage unit and the amplifier. Among the advantages of this system stands out for its ability to fast multichannel analysis and possess a simpler electronics. Values in energy resolution comparable with the literature were found using the developed electronics coupled to the radiation detector of NaI (Tl). The effects of collimators were evaluated by tomographic measurements in a multiphase fantom polymethyl methacrylate containing static components (iron, aluminum and air). Radiation sources with energies of the sources of 75Se (97 keV, 121 keV, 136 keV, 265 keV, 279 keV and 400 keV), 137Cs (662 keV) and 192Ir (317 keV, 468 keV and 602 keV) observed that the best image was obtained fantom collimators with rectangular windows (slits) 2 x 5 x 50 mm. In the dynamic evaluation of formation of bubbles column in a simulated industrial processes the best image at was obtained with the 192Ir source.
326

AVALIAÇÃO DA POSTURA CORPORAL DOS TRABALHADORES DA OFICINA DE REPARO DE VAGÕES DA REGIONAL II, DA COMPANHIA VALE DO RIO DOCE, ATRAVÉS DA BIOFOTOGRAMETRIA COMPUTADORIZADA / Evaluation of the Corporal Position of the Workers of the Workshop of Repair of Wagons of Regional II, of the CVRD, through the Computerized Biophotogrammetry.

Dalmácia Eller Fernandes Ramos 03 August 2007 (has links)
lt;p align="justify"gt;A utilização de posturas inadequadas durante a realização das atividades laborais, freqüentemente podem levar a uma aceleração do processo de desgaste sofrido pelo aparelho locomotor. O estudo da relação entre a postura adotada no trabalho e as alterações posturais são preocupação crescente de diversas áreas da ciência. Nesse contexto, o objetivo desse trabalho foi avaliar a postura corporal dos trabalhadores da oficina de reparo de vagões da Regional II, da Companhia Vale do Rio Doce (CVRD), através da Biofotogrametria Computadorizada, um método simples, prático e de fácil utilização. Com este método, procurou-se estabelecer uma metodologia simples e objetiva de qualificação e quantificação das alterações posturais em situações cotidianas do trabalhador, por meio de imagens capturadas e digitalizadas no software ALCimage® 2.0. Para análise descritiva dos dados utilizou-se, freqüências, medidas de posição, dispersão e correlação de Spearman (não-paramétrico) através do software SAEG 9.1 (Sistema de Análises Estatísticas e Genéticas). Para análise inferencial dos dados, utilizouse o teste não paramétrico Qui-Quadrado através do software GraphdPad Prism 5.0. A significância adotada nesse estudo foi de p lt; 0,05. Os resultados encontrados foram uma tendência de desequilíbrio postural para direita com correlação estatisticamente significativa nos principais segmentos corporais. Concluiu-se que o resultado encontrado foi obtido devido à dominância lateral uma vez que 91,70 % dos indivíduos eram destros.lt;/pgt; / lt;p align="justify"gt;The use of inappropriate posture in carrying out industrial activities, can often lead to an acceleration of the process of wear suffered by the locomotor apparatus. The study of the relationship between the stance adopted at work and postural changes are increasing concern in various areas of science. In this context, the objective of this work was to evaluate the attitude of the employees of the body shop for repair of wagons of the Regional II, the Companhia Vale do Rio Doce (CVRD), through Biofotogrametria Computer, a simple method, practical and easy to use. With this method, tried to establish a simple and objective method of qualification and quantification of postural changes in everyday situations of the worker, through images captured and digitized in the software ALCimage ® 2.0. For descriptive analysis of the data is used, frequencies, measures of position, dispersion and Spearman correlation of (non - parametric) by the software SAEG 9.1 (System for Genetic Analysis and Statistics). For analysis inferencial of data, the test used is not parametric Chi- Square through software GraphdPad Prism 5.0. The significance adopted in this study was p 0.05. The results were found a trend of postural imbalance to right with statistically significant correlation in the main body segments. It is concluded that the results were obtained due to dominance side since 91.70% of the subjects were dextrous.lt;/pgt;
327

Tomografia computadorizada de feixe cônico: modificação do protocolo de obtenção de imagens para diagnóstico precoce de alterações principais e incidentais de cabeça e pescoço

AMARAL, Lysandro Fabris Almeida do 29 March 2016 (has links)
Este trabalho visa propor um protocolo utilizando-se um FOV de maior amplitude, na fase de aquisição de imagens, geradas por aparelhos do tipo dedicado, juntamente com a definição de parâmetros de utilização de software, na interpretação das imagens reconstruídas pós-processamento para a obtenção de diagnósticos mais abrangentes nas regiões de cabeça e pescoço. Isso permite elevar a atenção multidisciplinar entre as áreas médico-odontológicas para assim aumentar as chances de detecções incidentais que estão além da razão inicial dos encaminhamentos. Para comprovar a possibilidade de potencializar os achados incidentais, foi realizado um levantamento em arquivos DICOM (Digital Imaging and Communication in Medicine) de pacientes atendidos em clínica privada, no período de janeiro de 2012 a julho de 2015, tendo o FOV estendido (Field of View- campo de visão do aparelho) permitindo, então, uma captação mais abrangente nas regiões de cabeça e pescoço. E nas opções de reconstruções de imagens pós-processamento utilizou-se de set-ups pré-ajustados no software i-CatVision, proporcionando uma maior chance de visualização estrutural, principalmente quando envolveram regiões de tecidos moles. Totalizando 223 pacientes considerados no padrão para o estudo, constataram-se repercussões odontológicas em 77,57% de alterações presentes nas regiões ósseas de maxila e mandíbula, incluindo 23,31 % de lesões periapicais sem nenhum tipo de tratamento endodôntico prévio e ainda, alterações em regiões da articulação temporomandibulares em 54,23%. As ocorrências fora da área de interesse primário relacionadas às especialidades médicas foram em percentual de 67,26% dos casos. Em seios paranasais 57,84%, mineralizações ou calcificações em partes moles em 45,37%, como as encontradas nos espaços tireoideanos e principalmente quando localizadas em áreas vasculares das regiões carotídeas extra e intracranianas, compreendidas respectivamente no “Bulbo Carotídeo” e no chamado “Polígono de Willis”, possibilitando talvez uma maior chance de detecção precoce de doenças crônico-degenerativas graves, como a aterosclerose e todas as suas conseqüências, contribuindo para a manutenção da saúde geral dos pacientes. Assim, pode ser observado que, com a modificação do FOV e ajustes de ferramentas nos softwares pós-processamento, proporcionaram maior chance de detecção de alterações incidentais. Ficou evidente, então, uma direta relação entre a amplitude do FOV e o diagnóstico de achados incidentais. / This study aims at proposing a protocol using an IS of greater amplitude, the image acquisition phase generated by the dedicated type devices together with the setting software usage parameters in interpreting the postprocessing reconstructed images to obtaining more comprehensive diagnostics in the regions of the head and neck. This allows raising the multidisciplinary care between medical and dental areas to thereby increase the chances of incidental detections that are beyond the initial reason for the referral. To prove the possibility of enhancing the incidental findings, a survey in DICOM files (Digital Imaging and Communication in Medicine) of patients treated in private clinic was conducted from January 2012 to July 2015, and extended FOV (Field of view- device field of vision) allows, then a more extensive capture the head and neck regions. And in the reconstruction options post-processing images was used to pre-set set-ups in the i-CatVision software, providing a greater chance of structural visualization, especially when involving soft tissue regions. Totalizing 223 patients considered the standard for the study, they found themselves dental repercussions in 77.57% of present changes in bone regions of maxilla and mandible, including 23.31% of periapical lesions without any previous endodontic treatment and also changes in regions of the temporomandibular joint in 54.23%. The events outside the area of ​​primary interest related to medical specialties were a percentage of 67.26% of cases. In paranasal sinuses 57.84%, mineralization or calcifications in the soft tissues at 45.37%, as found in the thyroid spaces and particularly when located in vascular areas of the extracranial and intracranial carotid regions comprised respectively in the "Carotid Bulb" and called "Polygon of Willis' enabling perhaps a greater chance of early detection of serious chronic degenerative diseases such as atherosclerosis and all its consequences, contributing to the maintenance of general health of patients. Thus, it can be seen that with modification of the FOV and tool adjustments in the software post-processing, provided a higher chance of detecting incidental changes. It was evident, then, a direct relationship between the amplitude of the FOV and the diagnosis of incidental findings.
328

Avaliação comparativa dos coeficientes de Hounsfield entre a tomografia computadorizada de feixe cônico e tomografia multislice / Comparative evaluation of the coefficients of Hounsfield between cone computed tomography and multislice CT

Silva, Isabela Maria de Carvalho Crusoé 02 November 2011 (has links)
Orientador: Solange Maria de Almeida / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-09-11T21:16:55Z (GMT). No. of bitstreams: 1 Silva_IsabelaMariadeCarvalhoCrusoe_M.pdf: 2322395 bytes, checksum: 2378f18e1c22e49e20d1b9f0670b3d52 (MD5) Previous issue date: 2011 / Resumo: O objetivo no presente estudo foi comparar os coeficientes das unidades de Hounsfield (HU) em imagens adquiridas por tomografia de Feixe Cônico e tomografia multislice. Para tanto, foram utilizadas imagens de vinte mandíbulas maceradas adquiridas em dois tomógrafos: tomógrafo multislice de 40 canais (Somatom Sensation 40 - Siemens) com protocolo de cortes axiais de 0,7 mm de espessura e intervalo entre os cortes de 0,5 mm; e tomógrafo de feixe cônico i-CAT (Imaging Sciences International), com cortes axiais de 0,2 mm de espessura, tempo de aquisição de 40 segundos e Field of View (FOV) de 8 cm. As análises das imagens foram feitas pelos softwares Syngo CT (tomógrafo multislice). Os valores obtidos por este último foram considerados como Padrão Ouro. Para as mensurações foram utilizadas as coordenadas X e Y, bem como a ferramenta de HU de ambos os softwares. Ficando assim, viável a comparação dos resultados após as Análises Estatísticas Descritivas e do Teste t pareado. Os dados obtidos indicaram um valor médio das regiões de interesse de 313,13 HU para a tomografia multislice e de 418.06 HU para a tomografia de feixe cônico, com valor de P < 0,001. Portanto, os valores de HU, obtidos pelo software da tomografia de feixe cônico, apresentaram-se superestimados em relação aos encontrados no Tomógrafo multislice. Na ausência de correspondência entre os dados amostrados, a tomografia de feixe cônico não oferece segurança e credibilidade ao cirurgião-dentista na avaliação da densidade óssea no planejamento para implantes e em cirurgias do complexo maxilofacial / Abstract: The aim of this study was to compare the attenuation coefficients (Hounsfield Unit) in both cone-beam computed tomography (CT) and multislice CT images. The 40-channel CT scanner (SOMATOM Sensation 40 - Siemens) was used to obtain images (n=20) of macerated mandibles considering the following protocol: axial slices of 0.7 mm in thickness and an interval of 0.5 mm between cuts. This same sample was submitted to i-CAT cone-beam CT scanner (Imaging Sciences International): axial slices of 0.2 mm in thickness and a field of view of 8 cm. Images were analyzed by means of computer software - XoranCat (cone-beam CT scan) and the Syngo CT (multislice CT scan) - the latter of which was considered Gold Standard. Coordinates X and Y and the HU tool were used for the measurements. Data were submitted to the descriptive statistical analysis and the paired sample t-test. A mean value of 313.13 HU was obtained for Multislice CT and 418.06 HU for the cone-beam CT (p<0.001). The attenuation coefficient values obtained for the cone-beam CT were overestimated when compared to those for the multislice CT. Since no correspondence was found among the data sampled, cone-beam CT offers no credibility for the dentist to evaluate bone during planning of implant and/or maxillofacial complex surgery / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica
329

Simulação de espectros de plasmas moleculares via rede neural artificial.

Joares Lidovino dos Reis Junior 00 December 2004 (has links)
Neste trabalho fazemos uma aplicação das redes neurais artificiais (RNA) do tipo funções de base radial (RBFN) em espectroscopia molecular, mais precisamente em espectros moleculares no nitrogênio. Verificamos a capacidade de uma RBFN em simular espectros experimentais para diversas condições de pressão e corrente de descarga. O parâmetro usado para verificar a qualidade das simulações foi a temperatura. Os resultados destas simulações foram usados para treinar uma outra RNA, acoplada a primeira, que através de informações de pressão e corrente, não usadas no treinamento, pode prever o espectro experimental e o valor da temperatura. A mesma metodologia foi usada para estudos de espectros em função da resolução. Nestas condições a RNA pode obter espectros com resoluções melhores do que as experimentais.
330

Controle preditivo de uma bomba de infusão de insulina para regulação da glicemia em pacientes diabéticos tipo I.

Cleiton Diniz Pereira da Silva e Silva 00 December 2004 (has links)
O presente trabalho visa a investigar, via simulação numérica, o desempenho de um controlador preditivo generalizado aplicado à regulação da glicemia em pacientes diabéticos tipo I, mediante o emprego de bombas de infusão de insulina. A simulação da dinâmica do sistema endócrino-metabólico em um paciente diabético tipo I, metabolicamente normalizado, foi realizada através de um modelo não-linear de 19a ordem bastante difundido na literatura. Em pacientes diabéticos tipo I, metabolicamente não-normalizados, tal dinâmica foi simulada considerando-se variações, em relação aos valores nominais, nos valores dos parâmetros do modelo anterior. O controlador projetado, quando atuando em um paciente diabético metabolicamente normalizado, teve o seu desempenho avaliado pelos valores máximos e mínimos da concentração de glicose no sangue periférico venoso e pelo intervalo de tempo para a concentração de glicose anterior retornar à faixa de 2% em torno da concentração de referência, após uma refeição contendo uma quantidade pré-fixada de glicose. Quando o controlador proposto atuava em um paciente diabético metabolicamente não-normalizado, inicialmente descompensado, o seu desempenho foi avaliado pelo intervalo de tempo necessário para a glicemia retornar à faixa de 2% em torno da concentração de referência. O desempenho apresentado pelo controlador proposto neste trabalho é comparável aos já disponíveis na literatura sendo, entretanto, o controlador proposto aqui mais simples de ser implementado e menos custoso computacionalmente.

Page generated in 0.0558 seconds