• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 39
  • 15
  • 3
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 71
  • 71
  • 31
  • 28
  • 20
  • 19
  • 15
  • 13
  • 12
  • 11
  • 11
  • 11
  • 10
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Correction active des discontinuités pupillaires des télescopes à miroir segmenté pour l’imagerie haut contraste et la haute résolution angulaire / Active correction of pupil discontinuities on segmented telescopes for high contrast imaging and high angular resolution

Janin-Potiron, Pierre 19 October 2017 (has links)
La recherche de signes de vie extraterrestre par l'observation et la caractérisation d'exoplanètes est, entre autres, l'un des enjeux majeurs de l'astrophysique moderne. Cette quête se traduit de manière instrumentale par le développement de télescopes fournissant des résolutions angulaires supérieures à celles obtenues à l'heure actuelle. C'est pourquoi les projets de futurs très grands télescopes font usage de miroirs primaires dépassant les 30 mètres de diamètre. Leur conception est alors inévitablement basée, pour des raisons techniques et technologiques, sur une géométrie segmentée. De ce fait, la segmentation du miroir primaire implique une complexification des structures pupillaires du télescope. Dans le but d'atteindre les niveaux de qualité optique nécessaires aux applications scientifiques visées, la prise en compte et la correction des effets introduits par un mauvais alignement des segments est de prime importance puisque la résolution angulaire d'un télescope non cophasé serait équivalente à celle obtenue avec un segment individuel. Dans ce contexte, je développe dans cette thèse deux analyseurs de cophasage permettant de mesurer et de corriger les aberrations de piston, tip et tilt présentes sur une pupille segmentée. Le premier, nommé Self-Coherent Camera - Phasing Sensor (SCC-PS), est basé sur une analyse du signal en plan focal. Le second, nommé ZELDA - Phasing Sensor (ZELDA-PS), repose quant à lui sur une analyse du signal en plan pupille. Sont présentés dans ce manuscrit les résultats obtenus à l'aide de simulations numériques ainsi que ceux issus de l'implémentation de la SCC-PS sur un banc d'optique d'essai. / Searching for extraterrestrial life through the observation and characterization of exoplanets is, amongst others, one of the major goal of the modern astrophysics. This quest translate from an instrumental point of view to the development of telescope capable of reaching higher angular resolution that what is actually ongoing. That is why the future projects of extremely large telescopes are using primary mirrors exceeding the 30 meters in diameter. Their conception is consequently based, for technical and technological reasons, on a segmented geometry. The segmentation of the primary mirror therefore implies a growing complexity of the structure of its pupil. In order to reach the optical quality required by the sciences cases of interest, taking into account and correct for the effects introduced by a poor alignment of the segments is mandatory, as the angular resolution of a non-cophased telescope is equivalent to the one obtained with a single segment. In this context, I develop in this manuscript two cophasing sensors allowing to measure and correct for the aberrations of piston, tip and tilt present on a segmented pupil. The first one, the Self-Coherent Camera - Phasing Sensor (SCC-PS), is based on a focal plane analysis of the signal. The second one, the ZELDA - Phasing Sensor (ZELDA-PS), is based on a pupil plane analysis of the signal. The results obtained by means of numerical simulations and the first results coming from the implementation of the SCC-PS on an optical bench are presented in this manuscript.
62

Iterative Reconstruction Algorithm for Phase-Contrast X-Ray Imaging / Iterativ rekonstruktionsalgoritm för faskontraströntgen

Sadek, Ahmad, Pozzi, Ruben January 2020 (has links)
Phase-contrast imaging (PCI) is a modality of medical x-ray imaging that can solve one of the main limitations with conventional attenuation-based imaging: the imaging of materials with low attenuation coefficients, such as soft tissues. A modality of PCI, Propagation-based phase-contrast imaging (PBI), was used in this project. This method does not require any optical elements than those used in the conventional imaging; it does, however, require more processing compared to other kinds of PCI. In addition to the reduced image quality, the required image reconstruction process, with PCI, also requires several manual adjustments, which in turn results in a lot of time consuming. In order to achieve that, a simple iterative image reconstruction method that combines Simultaneous Iterative Reconstruction Technique (SIRT) and propagation-based phase-contrast imaging was developed. The proposed method was compared with another commonly used phase-retrieval method, Paganin's algorithm. The obtained results showed higher resolution and reduced blur artefacts compared with Paganin's method. The developed method also appeared to be less sensitive to error in the input parameters, such as the attenuation coefficient, but also more time-consumption than the non-iterative Paganin's method, due to the higher data processing. / Faskontrastavbildning är en ny medicinsk röntgenavbildningsteknik, som har utvecklats för att ge bättre kontrast än konventionell röntgenavbildning, särskilt för objekt med låg attenuationskoefficient, såsom mjuk vävnad. I detta projekt användes s.k. propagationsbaserad faskonstrantavbildning, som är en av de enkla metoder som möjliggör faskontrastavbildningen, utan extra optiska element än det som ingår i en konventionell avbildning. Metoden kräver dock mer avancerad bildbehandling. Två av de huvudsakliga problemen som oftast uppstår vid faskontrastavbildning är minskad bildkvalité efter den väsentliga bildrekonstruktionen, samt att den är tidskrävande p.g.a. manuella justeringar som måste göras. I det här projektet implementerades en enkel metod baserad på en kombination av den iterativa algoritmen för bildrekonstruktion, Simultaneous Iterative Reconstruction Technique (SIRT), med propagationsbaserad faskonstrantavbildning. Resultaten jämfördes med en annan fasåterhämtningsmetod, som är välkänd och ofta används inom detta område, Paganinsmetod. Efter jämförelsen konstaterades att upplösningen blev högre och artefakter som suddighet reducerades. Det noterades också att den utvecklade metoden var mindre känslig för manuell inmatning av parametern för attenuationskoefficient. Metoden visade sig dock vara mer tidskrävande än Paganin-metoden.
63

Noninvasive Blood Flow and Oxygenation Measurements in Diseased Tissue

Rinehart, Benjamin S. 17 December 2021 (has links)
No description available.
64

Les premières images à haut contraste de binaires X

Prasow-Émond, Myriam 04 1900 (has links)
Les binaires X, composées d'un objet compact (naine blanche, étoile à neutrons ou trou noir stellaire) et d'une étoile donneuse, sont des objets fascinants qui ont permis faire des découvertes majeures dans le domaine de l'astrophysique des hautes énergies. Toutefois, l'environnement immédiat de ces dernières, à l'échelle de $\sim$ 100--10,000 unités astronomiques, n'est pour sa part que très peu compris et exploré. Dans ce mémoire, on s'intéresse à la présence de compagnons, autant de masse planétaire que stellaire, dans lesdits environnements des binaires X. Pour ce faire, on a fait appel à des techniques observationnelles qui sont normalement utilisées pour la recherche d'exoplanètes jeunes, chaudes et en orbite autour d'étoiles situées à quelques parsecs de la Terre : il s'agit de l'imagerie directe ou plus précisément de l'imagerie à haut contraste. Ainsi, pour la toute première fois, on a appliqué ces méthodes sur un échantillon de binaires X avec l'instrument proche infrarouge NIRC2 de l'Observatoire W. M. Keck, avec l'aide d'un système d'optique adaptative et d'un coronographe. Ici, on a présenté les premières images à haut contraste de 14 binaires X. Le but était de détecter des sources lumineuses dans les images et de calculer leur flux et leur position avec des méthodes d'optimisation. Ensuite, il s'agissait de définir via diverses analyses si celles-ci sont cohérentes avec des compagnons liés par la gravité à la binaire X, ou plutôt avec des étoiles de fond. Ces travaux se veulent donc une introduction à un nouveau sous-domaine de l'astrophysique qui tente de relier l'exoplanétologie et l'astrophysique des hautes énergies. / X-ray binaries, consisting of a compact object (white dwarf, neutron star or stellar-mass black hole) and a donor star, are fascinating objects that have allowed major breakthroughs in the field of high-energy astrophysics. However, their immediate environments, on the scale of $\sim$ 100--10,000 astronomical units, are still poorly understood. In this Master's thesis, we investigated the presence of companions, ranging from planetary to stellar masses, in the environments of X-ray binaries. In order to do so, we used observational techniques that are normally used for the search of young, hot and distant exoplanets orbiting stars located at a few parsecs from the Earth: direct imaging or more precisely high-contrast imaging. Thus, for the very first time, we applied these techniques on a sample of X-ray binaries with the near-infrared instrument NIRC2 of the W. M. Keck Observatory, with the help of an adaptive optics system and a coronagraph. Here, we present the first high-contrast images for 14 X-ray binaries. The goal was to detect point sources in the images and to calculate their flux and position with optimization methods. Afterward, we determined via a variety of analyses if these were consistent with companions gravitationally bounded to the X-ray binary, or rather with background stars. This work acts as an introduction, albeit exploratory, to a new subfield of astrophysics that attempts to link exoplanetology and high-energy astrophysics.
65

Holographic imaging of cold atoms

Turner, Lincoln David Unknown Date (has links) (PDF)
This thesis presents a new optical imaging technique which measures the structure of objects without the use of lenses. Termed diffraction-contrast imaging (DCI), the method retrieves the object structure from a Fresnel diffraction pattern of the object, using a deconvolution algorithm. DCI is particularly adept at imaging highly transparent objects and this is demonstrated by retrieving the structure of an almost transparent cloud of laser-cooled atoms. Applied to transparent Bose-Einstein condensates, DCI should allow the non-destructive imaging of the condensate while requiring only the minimum possible apparatus of a light source and a detector. (For complete abstract open document)
66

Contrôle optimal géométrique : méthodes homotopiques et applications / Geometric optimal control : homotopic methods and applications

Cots, Olivier 20 September 2012 (has links)
Le contexte de ce travail est le contrôle optimal géométrique appliqué à la mécanique céleste et au contrôle quantique. On s’est tout d’abord intéressé au problème de transfert orbital de satellite autour de la Terre à consommation minimale,qui amena à la réalisation du code HamPath, permettant tout d’abord la résolution de problème de contrôle optimal dont la loi de commande est lisse. Il se base sur le Principe du Maximum de Pontryagin (PMP) et sur la notion de point conjugué. Ce programme combine méthode de tir, méthodes homotopiques différentielles et calcul des conditions d’optimalité du deuxième ordre. Nous nous intéressons par la suite au contrôle quantique. On étudie tout d’abord le contrôle d’un système composé de deux types de particules de spin 1/2 ayant des temps de relaxation différents et dont la dynamique est gouvernée par les équations de Bloch. Ces deux sous-systèmes,correspondant aux deux types de particules, sont couplés par un même contrôle (un champ electromagnétique), le but étant alors d’amener la magnétisation des particules du premier type à zéro tout en maximisant celle du second (dans un système de coordonnées bien choisi). Ce modèle intervient en imagerie médicale par Résonance Magnétique Nucléaire et consiste à maximiser le contraste entre deux régions d’une même image. L’utilisation des outils géométriques et numériques aura permis de donner une très bonne synthèse sous-optimale pour deux cas particuliers (mélange sang oxygéné/désoxygéné et liquide cérébrospinal/eau). La dernière contribution de cette thèse porte sur l’étude d’un système quantique à deux niveaux d’énergie dontl a dynamique est régie par les équations de Lindblad. Le modèle est basé sur la minimisation d’énergie du transfert. On se restreint à un cas particulier pour lequelle Hamiltonien donné par le PMP est Liouville intégrable. On décrit alors les lieux conjugués et de coupure pour ce problème riemannien avec dérive / This work is about geometric optimal control applied to celestial and quantum mechanics. We first dealt with the minimum fuel consumption problem of transfering a satellite around the Earth. This brought to the creation of the code HamPath which permits first of all to solve optimal control problem for which the command law is smooth. It is based on the Pontryagin Maximum Principle (PMP) and on the notion of conjugate point. This program combines shooting method, differential homotopic methods and tools to compute second order optimality conditions. Then we are interested in quantum control. We study first a system which consists in two different particles of spin 1/2 having two different relaxation time. Both sub-systems are driven by the same control. The problem consists in bringing to zero the magnetization of one of the two system while maximizing the magnetization of the second one. This problem comes from constrast imaging in Nuclear Magnetic Resonance and consists in maximising the contrast between two areas of the image. The use of geometrical and numerical tools has given a very precise sub-optimal synthesis for two particular cases (deoxygenated/oxygenated blood and cerebrospinal fluid/water cases). The last contribution of this thesis is about the Lindblad equations in the two-level case. The model is based upon the minimisation of the transfer energy. We restrict the study to a particular case for which the Hamiltonian given by the PMP is Liouville integrable.We describe the conjugate and cut loci for this Riemannian with drift problem
67

Evoluční algoritmy pro ultrazvukovou perfúzní analýzu / Evolution algorithms for ultrasound perfusion analysis

Hemzalová, Zuzana January 2021 (has links)
This thesis deals with the principles of ultrasonic perfusion analysis and methods for determining perfusion parameters. It examines Evolutionary algorithms and their ability to optimize the approximation of dilution curves from ultrasond tissue scannig. It compares the optimization performance of three evolutionary algorithms. Continuous genetic algorithm GA, algorithm SOMA and PSO. Methods are evaluated on simulated and clinical data.
68

Étude de la tomodensitométrie spectrale quantitative et ses applications en radiothérapie

Simard, Mikaël 02 1900 (has links)
La tomodensitométrie par rayons-X (CT) est une modalité d’imagerie produisant une carte tridimensionnelle du coefficient d’atténuation des rayons-X d’un objet. En radiothérapie, le CT fournit de l’information anatomique et quantitative sur le patient afin de permettre la planification du traitement et le calcul de la dose de radiation à livrer. Le CT a plusieurs problèmes, notamment (1) une limitation au niveau de l’exactitude des paramètres physiques quantitatifs extraits du patient, et (2) une sensibilité aux biais causés par des artéfacts de durcissement du faisceau. Enfin, (3) dans le cas où le CT est fait en présence d’un agent de contraste pour améliorer la planification du traitement, il est nécessaire d’effectuer un deuxième CT sans agent de contraste à des fins de calcul de dose, ce qui augmente la dose au patient. Ces trois problèmes limitent l’efficacité du CT pour certaines modalités de traitement qui sont plus sensibles aux incertitudes comme la protonthérapie. Le CT spectral regroupe un ensemble de méthodes pour produire plusieurs cartes d’atténuation des rayons-X moyennées sur différentes plages énergétiques. L’information supplémentaire, pondérée en énergie qui est obtenue permet une meilleure caractérisation des matériaux analysés. Le potentiel de l’une de ces modalités spectrales, le CT bi-énergie (DECT), est déjà bien démontré en radiothérapie, alors qu’une approche en plein essor, le CT spectral à comptage de photons (SPCCT), promet davantage d’information spectrale à l’aide de détecteurs discriminateurs en énergie. Par contre, le SPCCT souffre d’un bruit plus important et d’un conditionnement réduit. Cette thèse investigue la question suivante : y a-t-il un bénéfice à utiliser plus d’information résolue en énergie, mais de qualité réduite pour la radiothérapie ? La question est étudiée dans le contexte des trois problèmes ci-haut. Tout d’abord, un estimateur maximum a posteriori (MAP) est introduit au niveau de la caractérisation des tissus post-reconstruction afin de débruiter les données du CT spectral. L’approche est validée expérimentalement sur un DECT. Le niveau de bruit du pouvoir d’arrêt des protons diminue en moyenne d’un facteur 3.2 à l’aide de l’estimateur MAP. Celui-ci permet également de conserver généralement le caractère quantitatif des paramètres physiques estimés, le pouvoir d’arrêt variant en moyenne de 0.9% par rapport à l’approche conventionnelle. Ensuite, l’estimateur MAP est adapté au contexte de l’imagerie avec agent de contraste. Les résultats numériques démontrent un bénéfice clair à utiliser le SPCCT pour l’imagerie virtuellement sans contraste par rapport au DECT, avec une réduction de l’erreur RMS sur le pouvoir d’arrêt des protons de 2.7 à 1.4%. Troisièmement, les outils développés ci-haut sont validés expérimentalement sur un micro-SPCCT de la compagnie MARS Bioimaging, dont le détecteur à comptage de photons est le Medipix 3, qui est utilisé pour le suivi de particules au CERN. De légers bénéfices au niveau de l’estimation des propriétés physiques à l’aide du SPCCT par rapport au DECT sont obtenus pour des matériaux substituts à des tissus humains. Finalement, une nouvelle paramétrisation du coefficient d’atténuation pour l’imagerie pré-reconstruction est proposée, dans le but ultime de corriger les artéfacts de durcissement du faisceau. La paramétrisation proposée élimine les biais au niveau de l’exactitude de la caractérisation des tissus humains par rapport aux paramétrisations existantes. Cependant, aucun avantage n’a été obtenu à l’aide du SPCCT par rapport au DECT, ce qui suggère qu’il est nécessaire d’incorporer l’estimation MAP dans l’imagerie pré-reconstruction via une approche de reconstruction itérative. / X-ray computed tomography (CT) is an imaging modality that produces a tridimensional map of the attenuation of X-rays by the scanned object. In radiation therapy, CT provides anatomical and quantitative information on the patient that is required for treatment planning. However, CT has some issues, notably (1) a limited accuracy in the estimation of quantitative physical parameters of the patient, and (2) a sensitivity to biases caused by beam hardening artifacts. Finally, (3) in the case where contrast-enhanced CT is performed to help treatment planning, a second scan with no contrast agent is required for dose calculation purposes, which increases the overall dose to the patient. Those 3 problems limit the efficiency of CT for some treatment modalities more sensitive to uncertainties, such as proton therapy. Spectral CT regroups a set of methods that allows the production of multiple X-ray attenuation maps evaluated over various energy windows. The additional energy-weighted information that is obtained allows better material characterization. The potential of one spectral CT modality, dual-energy CT (DECT), is already well demonstrated for radiation therapy, while an upcoming method, spectral photon counting CT (SPCCT), promises more spectral information with the help of energy discriminating detectors. Unfortunately, SPCCT suffers from increased noise and poor conditioning. This thesis thus investigates the following question: is there a benefit to using more, but lower quality energy-resolved information for radiotherapy? The question is studied in the context of the three problems discussed earlier. First, a maximum a posteriori (MAP) estimator is introduced for post-reconstruction tissue characterization for denoising purposes in spectral CT. The estimator is validated experimentally using a commercial DECT. The noise level on the proton stopping power is reduced, on average, by a factor of 3.2 with the MAP estimator. The estimator also generally con- serves the quantitative accuracy of estimated physical parameters. For instance, the stopping power varies on average by 0.9% with respect to the conventional approach. Then, the MAP estimation framework is adapted to the context of contrast-enhanced imaging. Numerical results show clear benefits when using SPCCT for virtual non-contrast imaging compared to DECT, with a reduction of the RMS error on the proton stopping power from 2.7 to 1.4%. Third, the developed tools are validated experimentally on a micro-SPCCT from MARS Bioimaging, which uses the Medipix 3 chip as a photon counting detector. Small benefits in the accuracy of physical parameters of tissue substitutes materials are obtained. Finally, a new parametrization of the attenuation coefficient for pre-reconstruction imaging is pro- posed, whose ultimate aim is to correct beam hardening artifacts. In a simulation study, the proposed parametrization eliminates all biases in the estimated physical parameters of human tissues, which is an improvement upon existing parametrizations. However, no ad- vantage has been obtained with SPCCT compared to DECT, which suggests the need to incorporate MAP estimation in the pre-reconstruction framework using an iterative reconstruction approach.
69

Koherencí řízený holografický mikroskop / COHERENCE-CONTROLLED HOLOGRAPHIC MICROSCOPE

Kolman, Pavel January 2010 (has links)
ransmitted-light coherence-controlled holographic microscope (CCHM) based on an off-axis achromatic and space-invariant interferometer with a diffractive beamsplitter has been designed, constructed and tested. It is capable to image objects illuminated by light sources of arbitrary degree of temporal and spatial coherence. Off-axis image-plane hologram is recorded and the image complex amplitude (intensity and phase) is reconstructed numerically using fast Fourier transform algorithms. Phase image represents the optical path difference between the object and the reference arms caused by presence of an object. Therefore, it is a quantitative phase contrast image. Intensity image is confocal-like. Optical sectioning effect induced by an extended, spatial incoherent light source is equivalent to a conventional confocal image. CCHM is therefore capable to image objects under a diffusive layer or immersed in a turbid media. Spatial and temporal incoherence of illumination makes the optical sectioning effect stronger compared to a confocal imaging process. Object wave reconstruction from the only one recorded interference pattern ensures high resistance to vibrations and medium or ambience fluctuations. The frame rate is not limited by any component of the optical setup. Only the detector and computer speeds limit the frame rate. CCHM therefore allows observation of rapidly varying phenomena. CCHM makes the ex-post numerical refocusing possible within the coherence volume. Coherence degree of the light source in CCHM can be adapted to the object and to the required image properties. More coherent illumination provides wider range of numerical refocusing. On the other hand, a lower degree of coherence makes the optical sectioning stronger, i.e. the optical sections are thiner, it reduces coherence-noise and it makes it possible to separate the ballistic light. In addition to the ballistic light separation, CCHM enables us to separate the diffused light. Multi-colour-light
70

Iterative tomographic X-Ray phase reconstruction / Reconstruction tomographique itérative de phase

Weber, Loriane 30 September 2016 (has links)
L’imagerie par contraste de phase suscite un intérêt croissant dans le domaine biomédical, puisqu’il offre un contraste amélioré par rapport à l’imagerie d’atténuation conventionnelle. En effet, le décalage en phase induit par les tissus mous, dans la gamme d’énergie utilisée en imagerie, est environ mille fois plus important que leur atténuation. Le contraste de phase peut être obtenu, entre autres, en laissant un faisceau de rayons X cohérent se propager librement après avoir traversé un échantillon. Dans ce cas, les signaux obtenus peuvent être modélisés par la diffraction de Fresnel. Le défi de l’imagerie de phase quantitative est de retrouver l’atténuation et l’information de phase de l’objet observé, à partir des motifs diffractés enregistrés à une ou plusieurs distances. Ces deux quantités d’atténuation et de phase, sont entremêlées de manière non-linéaire dans le signal acquis. Dans ces travaux, nous considérons les développements et les applications de la micro- et nanotomographie de phase. D’abord, nous nous sommes intéressés à la reconstruction quantitative de biomatériaux à partir d’une acquisition multi-distance. L’estimation de la phase a été effectuée via une approche mixte, basée sur la linéarisation du modèle de contraste. Elle a été suivie d’une étape de reconstruction tomographique. Nous avons automatisé le processus de reconstruction de phase, permettant ainsi l’analyse d’un grand nombre d’échantillons. Cette méthode a été utilisée pour étudier l’influence de différentes cellules osseuses sur la croissance de l’os. Ensuite, des échantillons d’os humains ont été observés en nanotomographie de phase. Nous avons montré le potentiel d’une telle technique sur l’observation et l’analyse du réseau lacuno-canaliculaire de l’os. Nous avons appliqué des outils existants pour caractériser de manière plus approfondie la minéralisation et les l’orientation des fibres de collagènes de certains échantillons. L’estimation de phase, est, néanmoins, un problème inverse mal posé. Il n’existe pas de méthode de reconstruction générale. Les méthodes existantes sont soit sensibles au bruit basse fréquence, soit exigent des conditions strictes sur l’objet observé. Ainsi, nous considérons le problème inverse joint, qui combine l’estimation de phase et la reconstruction tomographique en une seule étape. Nous avons proposé des algorithmes itératifs innovants qui couplent ces deux étapes dans une seule boucle régularisée. Nous avons considéré un modèle de contraste linéarisé, couplé à un algorithme algébrique de reconstruction tomographique. Ces algorithmes sont testés sur des données simulées. / Phase contrast imaging has been of growing interest in the biomedical field, since it provides an enhanced contrast compared to attenuation-based imaging. Actually, the phase shift of the incoming X-ray beam induced by an object can be up to three orders of magnitude higher than its attenuation, particularly for soft tissues in the imaging energy range. Phase contrast can be, among others existing techniques, achieved by letting a coherent X-ray beam freely propagate after the sample. In this case, the obtained and recorded signals can be modeled as Fresnel diffraction patterns. The challenge of quantitative phase imaging is to retrieve, from these diffraction patterns, both the attenuation and the phase information of the imaged object, quantities that are non-linearly entangled in the recorded signal. In this work we consider developments and applications of X-ray phase micro and nano-CT. First, we investigated the reconstruction of seeded bone scaffolds using sed multiple distance phase acquisitions. Phase retrieval is here performed using the mixed approach, based on a linearization of the contrast model, and followed by filtered-back projection. We implemented an automatic version of the phase reconstruction process, to allow for the reconstruction of large sets of samples. The method was applied to bone scaffold data in order to study the influence of different bone cells cultures on bone formation. Then, human bone samples were imaged using phase nano-CT, and the potential of phase nano-imaging to analyze the morphology of the lacuno-canalicular network is shown. We applied existing tools to further characterize the mineralization and the collagen orientation of these samples. Phase retrieval, however, is an ill-posed inverse problem. A general reconstruction method does not exist. Existing methods are either sensitive to low frequency noise, or put stringent requirements on the imaged object. Therefore, we considered the joint inverse problem of combining both phase retrieval and tomographic reconstruction. We proposed an innovative algorithm for this problem, which combines phase retrieval and tomographic reconstruction into a single iterative regularized loop, where a linear phase contrast model is coupled with an algebraic tomographic reconstruction algorithm. This algorithm is applied to numerical simulated data.

Page generated in 0.1157 seconds