• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 290
  • 20
  • 20
  • 2
  • 1
  • 1
  • Tagged with
  • 334
  • 260
  • 255
  • 229
  • 208
  • 153
  • 143
  • 119
  • 107
  • 72
  • 66
  • 58
  • 50
  • 47
  • 46
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Efeito do Agregado Tri?xido Mineral intracanal em um modelo de reimplante tardio em dentes de ratos : an?lise histol?gica e imunoistoqu?mica

Vogt, Beatriz Farias 22 July 2011 (has links)
Made available in DSpace on 2015-04-14T13:30:00Z (GMT). No. of bitstreams: 1 433436.pdf: 11903590 bytes, checksum: 4163e55cbb5eaeaad64c27591c93d62c (MD5) Previous issue date: 2011-07-22 / O reimplante ? o tratamento de escolha da avuls?o dent?ria. Deve ser realizado imediatamente, a fim de evitar que ocorra necrose pulpar e do ligamento periodontal e, consequentemente, o desenvolvimento de reabsor??o radicular. Por?m, quando a reabsor??o estiver instalada, a terapia com hidr?xido de c?lcio deve ser iniciada t?o logo quanto poss?vel. Pelo fato deste material ainda apresentar alguns inconvenientes, como a necessidade de trocas frequentes e o aumento da fragilidade da estrutura dent?ria quando utilizado por longos per?odos, outros materiais est?o sendo utilizados como substitutos do hidr?xido de c?lcio. Sendo assim, o objetivo deste trabalho foi de, atrav?s de uma revis?o da literatura, conhecer a aplicabilidade do agregado tri?xido mineral no tratamento de dentes traumatizados. Al?m disso, tamb?m foi realizado um estudo experimental para avaliar o efeito do MTA Branco (WMTA) (Angelus, Londrina, Brasil) e do MTA Fillapex (Angelus, Londrina Brasil) como medica??o intracanal na preven??o da reabsor??o radicular, em dentes de ratos, reimplantados tardiamente. Neste estudo foram utilizados 48 ratos machos (Wistar) que tiveram o incisivo central superior direito extra?do e mantido em meio seco por 30 minutos. Os animais foram divididos em quatro grupos: 1 WMTA; 2 MTA Fillapex; 3 Hidr?xido de c?lcio; 4 Controle negativo. Ap?s a remo??o qu?mica do ligamento periodontal, os canais radiculares foram secos, preenchidos com o material correspondente a cada grupo e reimplantados. Ap?s 10 e 60 dias, as pe?as operat?rias foram submetidas ao processamento para realiza??o de cortes histol?gicos no sentido longitudinal. As l?minas foram coradas com HE para an?lise histol?gica qualitativa e quantitativa. Os resultados foram analisados estatisticamente por meio de an?lise de vari?ncia (ANOVA), seguida pelo Teste de Tukey, com n?vel de signific?ncia de 5%. A avalia??o qualitativa demonstrou que os grupos do WMTA e MTA Fillapex apresentaram ?reas de reabsor??o inflamat?ria, reabsor??o por substitui??o e anquilose alv?olo-dent?ria, similares ?s observadas no grupo do hidr?xido de c?lcio, nos dois per?odos avaliados. Um processo inflamat?rio maior foi observado nos grupos WMTA e MTA Fillapex. Na an?lise quantitativa, a avalia??o do processo inflamat?rio mostrou diferen?a significativa entre o grupo do hidr?xido de c?lcio e o grupo controle, aos 10 dias (p<0.05). Aos 60 dias, ?reas de anquilose alv?olodent?ria foram significativamente maiores no grupo MTA Fillapex quando comparado ao grupo controle (p<0.05). Os resultados mostraram que nenhum dos materiais avaliados foi capaz de prevenir completamente o desenvolvimento da reabsor??o radicular, apesar de ambos os materiais ? base de MTA terem apresentado resultados compar?veis aos do hidr?xido de c?lcio. Sendo assim, os cimentos de MTA podem apresentar algumas vantagens; por?m, as consequ?ncias dos seus efeitos pro-inflamat?rios devem ser mais bem investigadas.
32

Influ?ncia da irradia??o com laser nd:yag associado ao fl?or nos valores de resist?ncia de uni?o de sistemas adesivos ?s dentinas sadia e cariada

Paranhos, Maria Paula Gandolfi 08 December 2006 (has links)
Made available in DSpace on 2015-04-14T13:30:04Z (GMT). No. of bitstreams: 1 386672.pdf: 7738475 bytes, checksum: 131327351db4ceb85e7af5e5a7ef43e8 (MD5) Previous issue date: 2006-12-08 / Este estudo avaliou, in vitro, a resist?ncia de uni?o ? microtra??o dos sistemas adesivos Single Bond - SB (3M/ESPE) e Clearfil SE Bond - CSE (Kuraray) ? dentina sadia e cariada, com ou sem aplica??o pr?via do laser Nd:YAG associado ou n?o a presen?a de fl?or. A superf?cie oclusal de 60 terceiros molares humanos foi removida para obten??o de uma superf?cie dentin?ria plana. Metade destes dentes foram submetidos ? ciclagem de pH para realiza??o de c?rie artificial e a outra metade permaneceu com a dentina h?gida. Os dentes foram divididos em 12 grupos, sendo que a dentina dos grupos 1-6 era cariada e dos grupos 7-12 sadia. Foram realizados 3 tratamentos distintos: irradia??o da dentina com laser Nd:YAG (60 mJ, 15 Hz e 0,9 W); irradia??o da dentina com laser Nd:YAG associado ao fl?or em gel; e sem tratamento (controle). Doze dentes, tratados como descrito acima, foram utilizados para avalia??o da microdureza, para an?lise em MEV e espectroscopia por energia dispersiva (EDS). Nos dentes dos grupos experimentais, a aplica??o dos sistemas adesivos foi realizada de acordo com as instru??es dos fabricantes e um plat? de resina composta (Z250/3M) com aproximadamente 6 mm de altura foi realizado. Ap?s, os esp?cimes foram armazenados em ?gua destilada por 24 h em uma estufa de cultura a 37?C. Decorrida esta etapa, os dentes foram seccionados nos sentidos x e y para obten??o de palitos (25 por grupo) com ?rea adesiva de 0,8 mm2. Estes palitos foram submetidos ao ensaio de microtra??o, em uma m?quina de ensaios mec?nicos (EMIC-DL), com velocidade de 0,5 mm/min. O padr?o de falha foi caracterizado pela an?lise em MEV e an?lise fractogr?fica. Segundo o modelo linear geral univariado (GLM) e Tukey (p < 0,05), as maiores m?dias foram obtidas quando os sistemas adesivos foram aplicados em dentina sadia, de acordo com as instru??es dos fabricantes (SB 34,2 MPa e CSE 40,65 MPa). Os resultados tamb?m mostraram que a presen?a de tecido cariado reduziu significativamente a resist?ncia de uni?o dos dois sistemas adesivos utilizados. A irradia??o da dentina com laser diminuiu a resist?ncia de uni?o do Clearfil SE Bond e n?o afetou os dentes tratados com o Single Bond. A irradia??o da dentina sadia com laser associado ao fl?or reduziu os valores de resist?ncia de uni?o para os dois sistemas adesivos, embora este tratamento em dentina cariada, utilizando o Clearfil SE 12 Bond tenha mostrado resultados superiores ao Single Bond. O tipo de falha predominante foi a falha do tipo mista. A an?lise em MEV da dentina sadia, ap?s aplica??o do laser, mostrou uma superf?cie com irregularidades e porosidades devido ? fus?o e recristaliza??o desta dentina, com t?bulos dentin?rios oclu?dos; a dentina cariada apresentou as mesmas caracter?sticas da dentina sadia irradiada, com t?bulos dentin?rios mais n?tidos devido ? reestrutura??o da dentina peritubular.
33

Efic?cia de dois m?todos de clareamento dental e sua influ?ncia sobre as propriedades f?sico-qu?micas e sobre a resist?ncia ? uni?o de sistemas adesivos

Marcondes, Maurem 19 January 2007 (has links)
Made available in DSpace on 2015-04-14T13:30:12Z (GMT). No. of bitstreams: 1 387564.pdf: 2940203 bytes, checksum: cf1530adcd62580b3d499dcac450127c (MD5) Previous issue date: 2007-01-19 / A fim de atender a crescente demanda por clareamento nos consult?rios odontol?gicos, pesquisas acerca de diferentes t?cnicas, concentra??es e f?rmulas de agentes clareadores est?o sendo realizadas. O objetivo desse estudo foi avaliar in vitro: A) a altera??o de cor de dentes humanos clareados com per?xido de hidrog?nio 35% associado ? corantes com diferentes comprimentos de onda e irradiados com laser de Nd:YAG ou luz hal?gena; B) a microdureza Vickers (VHN) destes esp?cimes antes e ap?s os tratamentos clareadores; C) topografia da superf?cie do esmalte pela MEV; D) a resist?ncia de uni?o ? tra??o de dois sistemas adesivos, um contendo acetona e o outro etanol; E) o padr?o de fratura dos corposde- prova com aux?lio da MEV ap?s o ensaio de resist?ncia de uni?o ? tra??o. Setenta e cinco molares humanos extra?dos tiveram a coroa seccionada no sentido m?sio-distal e os 150 fragmentos obtidos foram divididos em cinco grupos conforme o agente clareador e tipo de fotoativa??o: WL (Whiteness HP Maxx e Laser de Nd:YAG), WH (Whiteness HP Maxx e luz Hal?gena), QL (H2O2+carbopol+Q-Switch e laser de Nd:YAG), QH (H2O2+carbopol+QSwitch e luz Hal?gena) e C (Controle, sem clareamento). A avalia??o de cor pela escala Vita e o teste de microdureza Vickers foram realizados antes e depois dos tratamentos clareadores. Ap?s duas semanas de armazenamento em saliva artificial, os grupos foram subdivididos para a realiza??o dos tratamentos restauradores com os sistemas adesivos Adper Single Bond 2 e Solobond M e, logo ap?s, realizado o ensaio de resist?ncia ? tra??o e an?lise do padr?o de fratura. A cor variou sete n?veis para os grupos irradiados pelo laser de Nd:YAG e oito n?veis para os grupos irradiados pela luz hal?gena. De acordo com o teste t-student, n?o houve diferen?a significativa para a VHN antes e depois dos clareamentos (p>0,05). Segundo ANOVA, os valores de resist?ncia de uni?o n?o indicaram diferen?a estat?stica entre os grupos teste e seus controles para os dois tipos de adesivos testados (p>0,05), sendo o padr?o de fratura mais freq?ente o de falha mista. Houve altera??es na superf?cie do esmalte, todavia, n?o foram significativas a ponto de modificar a resist?ncia de uni?o dos sistemas adesivos. Conclu?-se que todos os protocolos realizados nesta pesquisa foram eficazes para o clareamento dos esp?cimes, bem como para o procedimento restaurador ap?s o tratamento
34

Compara??o da distribui??o de tens?es em dois tipos de conex?o prot?tica de implantes com parafusos diferentes utilizando o m?todo de an?lise por elementos finitos com modelo tridimensional

Herbstrith Segundo, Reg?nio Mahfuz 12 December 2006 (has links)
Made available in DSpace on 2015-04-14T13:30:17Z (GMT). No. of bitstreams: 1 388162.pdf: 14806898 bytes, checksum: 307d9a5db880718206e03f9e7a7c7223 (MD5) Previous issue date: 2006-12-12 / O objetivo deste estudo foi avaliar e comparar qualitativamente, atrav?s de an?lise por elementos finitos com modelo 3D, a distribui??o das tens?es geradas por cargas simuladas sob modelos de implantes, pilares, coroas prot?ticas metalocer?micas na regi?o de primeiros molares. As an?lises foram executadas em 4 modelos tridimensionais: modelo 1 e modelo 2 com encaixe prot?tico tipo hex?gono externo e parafuso de pilar de ouro e tit?nio respectivamente, modelo 3 e modelo 4 com encaixe tipo hex?gono interno e parafuso de pilar de ouro e tit?nio respectivamente, a carga aplicada foi padronizada em 382N com duas angula??es diferentes, inclina??es de 90? com a superf?cie oclusal e de 15? em rela??o ao longo eixo dos implantes, em dois pontos distintos, 4 e 6 mm do centro do implante, em 10 pontos diferentes de observa??o no conjunto implante-pilar-parafuso. Os resultados obtidos sugeriram que de uma maneira geral, os modelos com encaixe interno (3 e 4) possuem um melhor comportamento mec?nico em rela??o a distribui??o de tens?es ao longo do complexo implante-pilar-parafuso. Nos modelos 1 e 2 o tipo de material que o parafuso de pilar ? feito influencia na distribui??o de tens?es, por outro lado, nos modelos 3 e 4 isto n?o foi observado
35

An?lise comparativa da microinfiltra??o marginal em ?pices retro-obturados com MTA e cimento Ion?mero de vidro

Hellwig, Ingeburg 13 December 2005 (has links)
Made available in DSpace on 2015-04-14T13:30:18Z (GMT). No. of bitstreams: 1 342794.pdf: 1868872 bytes, checksum: 69d37d7562fb1d7b65e4a9f9cb3dc939 (MD5) Previous issue date: 2005-12-13 / As cirurgias paraendod?nticas exp?em e removem ?pices dentais, promovem retrocavita??es no longo eixo dos canais radiculares e as retro-obturam com materiais que promovem seu selamento. Esta pesquisa avaliou in vitro, por interm?dio do teste de microinfiltra??o apical, por corante Rodamina B a 0,2 % e morfometria computadorizada, 30 dentes humanos permanentes unirradiculares, submetidos a tratamento endod?ntico e divididos em tr?s grupos: A apicectomia por broca em 90 graus, retrocavidade com ultra-som e retro-obtura??o com MTA Angelus? ; B apicectomia por broca em 90 graus, retrocavidade com ultra-som e retro-obtura??o com Vitremer?; C - apicectomia por broca em 90 graus, retrocavidade com ultra-som e retro-obtura??o com MTA ProRoot?. A an?lise comparativa, por meio dos testes estat?sticos de Kolmogorov-Smimov, Coeficiente de Correla??o de Pearson e An?lise de Vari?ncia, complementada pelo teste de Tukey, demonstrou que, com o Vitremer?, se obtiveram os melhores resultados, enquanto os dois materiais MTA apresentaram resultados equivalentes. Pode-se considerar os tr?s materiais testados satisfat?rios como retro-obturadores apicais.
36

Influ?ncia dos cimentos resinosos na deflex?o de c?spides de pr?-molares tratados endodonticamente e restaurados com inlays em resina composta

Rosa, Helen Cristina Vieira da 01 March 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:19Z (GMT). No. of bitstreams: 1 Helen Cristina Vieira da Rosa.pdf: 575465 bytes, checksum: 907bc1dd4c8788ff1bcb0479b1249fc5 (MD5) Previous issue date: 2013-03-01 / The aim of this study was to evaluate the influence of different resin cements in the cuspal deflection of teeth with endodontic treatment. Sixty superior premolars were randomly divided into five (n=12) groups: 1 sound teeth; 2 cavity; 3 - Rely X ARC; 4 RelyX U100; 5 SeT. The teeth from groups 2, 3, 4 and 5 received a MOD preparation and endodontic treatment. Impressions were made with vinyl polysiloxane and poured using type IV die stone in groups 3, 4 and 5. Inlays with Z250 composite resin were built over each cast and luted with the resin cements according manufacturer s instructions. The specimens were stored in distilled water at 37o C for 72 hours. The specimens were positioned in a universal testing machine and a load of 200 N was applied in the oclusal region with a steel rod with 8 mm in diameter. The cusp deflection was measured after and before the load by means a micrometer that contacted the buccal and palatine faces. After 24 h, the cuspal deflection was measured again using a load of 300 N. According to ANOVA and Tukey s test ( &#945;= 0.05), for both occlusal loads, the sound teeth presented the lowest mean cuspal deflection, differing statistically from the other groups. Intermediate values were obtained in RelyX ARC group and RelyX U100 group, differing statistically between them. The highest cuspal deflections were obtained in SeT group and cavity group, not differing statistically between them. According to the Student t-test, there was a statistically significant difference among the 200 N and 300 N occlusal loads for the cavity group (p = 0.002), RelyX U100 group (p = 0.000), and SeT group (p = 0.004). There was no statistical difference for the sound teeth group (p = 0.389), and RelyX ARC group (p = 0.188). The inlays luted with RelyX ARC obtained lower cuspal deflection in comparison with the self-adhesive resin cements; RelyX U100 showed lower cuspal deflection than SeT. / O objetivo desse trabalho foi avaliar a influ?ncia de diferentes cimentos resinosos na deflex?o de c?spides de dentes com tratamento endod?ntico. Sessenta pr?-molares superiores foram divididos aleatoriamente em cinco grupos (n=12): 1 - h?gidos; 2 - cavidades; 3 - RelyX ARC; 4 - RelyX U100; 5 - SeT. Os dentes dos grupos 2, 3, 4 e 5 receberam preparos MOD e tratamento endod?ntico. Os dentes dos grupos 3, 4 e 5 foram moldados com silicone por adi??o, seguido de vazamento de gesso tipo IV. Sobre cada modelo foi confeccionada uma restaura??o inlay em resina composta Z250. As restaura??es foram cimentadas com os cimentos resinosos, de acordo com cada grupo experimental, seguindo as instru??es dos fabricantes. Os corpos de prova foram armazenados em ?gua destilada a 37? C por 72 horas. Em m?quina de ensaio universal, uma carga de 200 N foi aplicada na regi?o oclusal com esfera de a?o de 8 mm de di?metro e, com o aux?lio de um micr?metro posicionado nas faces vestibular e palatina, a deflex?o das c?spides foi medida antes e ap?s a carga. Ap?s 24 horas, foi realizado o mesmo procedimento aplicando uma carga de 300 N na regi?o oclusal. De acordo com ANOVA e teste de Tukey (&#945;=0,05), para ambas as cargas, o menor valor m?dio de deflex?o de c?spides ocorreu no grupo dente h?gido, diferindo estatisticamente dos demais grupos. O segundo menor valor foi obtido para o grupo RelyX ARC, seguido do grupo RelyX U100, os quais diferiram estatisticamente entre si. As maiores m?dias de deflex?o de c?spides foram obtidas com o grupo SeT e o grupo dente com cavidade, n?o diferindo estatisticamente entre si. De acordo com o teste t-student para amostras pareadas (&#945;=0,05), houve diferen?a estat?stica para a m?dia de deflex?o de c?spides entre as cargas de 200 N e 300 N para o grupo cavidade (p = 0,002), o grupo RelyX U100 (p = 0,000), e o grupo SeT (p = 0,004). N?o houve diferen?a estat?stica para o grupo dente h?gido (p = 0,389) e para o grupo RelyX ARC (p = 0,188). As inlays fixadas com RelyX ARC tiveram deflex?o de c?spides inferior ? obtida com os cimentos resinosos autoadesivos, sendo que o RelyX U100 proporcionou menor deflex?o de c?spides em rela??o ao SeT.
37

Avalia??o da aplica??o de uma solu??o experimental inibidora de metaloproteinase na resist?ncia de uni?o mediata de sistemas adesivos

Melara, Rafael 21 March 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:20Z (GMT). No. of bitstreams: 1 447186.pdf: 2766501 bytes, checksum: a394900abd9b1fe55a4a5e1b39342bad (MD5) Previous issue date: 2013-03-21 / This study aimed to evaluate, in vitro, the mediate microtensile bond strength- &#956;TBS (12 months) of adhesive systems Adper Scotchbond SE / 3M/ESPE (Adper SE) and Adper Scotchbond Multi-Purpose / 3M/ESPE (Adper SMP) to sound dentin surface, treated or not with an experimental acid solution inhibitor of metalloproteinases (MMPs), as well as the predominant pattern of failure by fractography; and evaluate, in vitro, the inhibition of gelatinolytic activity by an experimental acid solution for dentin surface etching containing tetracycline compared with an experimental solution containing tetracycline. For mediate &#956;TBS evaluation, in Adper SE Control and Adper SMP Control groups, the adhesive system was applied according to the manufacturer's instructions. In Adper SE Experimental group was applied the experimental solution prior to the adhesive system, and in the Adper Experimental SMP group, the etching with 37% phosphoric acid was replaced by applying the experimental solution. After applying the adhesive systems, the teeth were prepared for &#956;TBS test, and the sticks were stored in an oven at 37?C. After 12 months &#956;TBS test was realized and the sticks were evaluated by SEM. For enzymatic activity evaluation, saliva samples were collected from healthy donors, centrifuged and the supernatant was used by technique of zymography. This technique was based on the use of electrophoresis, in which a protein substrate (gelatin) was co-polymerized with acrylamide. The enzymes were separated under non-reducing conditions, renatured and then incubated in suitable buffer, based on the association between the substrate digestion and verification of the molecular weight of proteases. To quantify the relative inhibition by the two solutions was used the Image J software (NIH, Bethesda, MD, USA) and compared with the control. For mediate &#956;TBS evaluation, according to the Tukey test (&#945; = 0.05), no difference between the control and experimental groups was found for each adhesive system. The predominant pattern of failure for the system Adper SE was cohesive in composite while for Adper SMP was cohesive in hybrid layer. In the enzymatic activity evaluation, the enzymes were characterized as matrix metalloproteinases, because its expression was inhibited by EDTA (a known inhibitor of MMPs), while NEM (an inhibitor of serine proteases) had no effect on enzymatic activity. The MMP identified in the study, was characterized as MMP-2, with a molecular weight of 62KDa. The experimental acid solution presented an inhibition of the gelatinolytic activity of 93.66% (concentration 0.05%) and 58.58% (0.01% concentration), while the experimental solution had a percentage inhibition of 31.28% and 6.83%, respectively. Based on these results we conclude that after 12 months of storage, the adhesive system Adper SE showed better performance that Adper SMP in the microtensile bond strength test, also seeming to be more effective in maintaining the integrity of the adhesive interface, under fractographic analysis; and that the experimental acid solution for dentin surface etching was capable of almost completely inhibits the enzymatic activity of MMP-2 in a dose dependent manner. / Este estudo teve por objetivo avaliar, in vitro, a resist?ncia de uni?o ? microtra??o (RUM) mediata (12 meses) dos sistemas adesivos Adper Scotchbond SE / 3M/ESPE (Adper SE) e Adper Scotchbond Multi-Uso / 3M/ESPE (Adper SMP) ? superf?cie dentin?ria sadia, tratada ou n?o com uma solu??o ?cida experimental inibidora de metaloproteinases (MMPs), bem como o padr?o predominante de falha por fractografia; e avaliar, in vitro, a inibi??o da atividade gelatinol?tica por uma solu??o ?cida experimental para condicionamento de superf?cie dentin?ria contendo tetraciclina em compara??o com uma solu??o experimental contendo tetraciclina. Para avalia??o da RUM mediata, nos grupos Adper SE Controle e Adper SMP Controle, o sistema adesivo foi aplicado de acordo com as instru??es do fabricante. No grupo Adper SE Experimental foi aplicada a solu??o experimental previamente ao sistema adesivo, e no grupo Adper SMP Experimental, o condicionamento com ?cido fosf?rico a 37% foi substitu?do pela aplica??o da solu??o experimental. Ap?s a aplica??o dos sistemas adesivos, os dentes foram preparados para o teste de RUM, e os palitos obtidos foram armazenados em estufa a 37oC. Ap?s 12 meses, foi realizado o teste RUM e os palitos foram avaliados em MEV. Para avalia??o da atividade enzim?tica, amostras salivares foram coletadas de doadores saud?veis, centrifugadas e o sobrenadante foi usado atrav?s da t?cnica zimogr?fica. Esta t?cnica baseou-se no uso da eletroforese, no qual um substrato proteico (gelatina) foi co-polimerizado com acrilamida. As enzimas foram separadas sob condi??es n?o redutoras, renaturadas e ent?o incubadas em tamp?o adequado, baseando-se na associa??o entre digest?o do substrato e verifica??o do peso molecular das proteases. Para quantificar a inibi??o relativa pelas duas solu??es foi usado o programa Image J (NIH, Bethesda, MD, USA) e comparadas com o controle. Em rela??o ? RUM mediata, de acordo com o teste de Tukey (&#945;=0.05), n?o houve diferen?a entre os grupos controle e experimental para cada sistema adesivo. O padr?o predominante de falha para o sistema adesivo Adper SE foi coesiva em resina composta enquanto que para o Adper SMP foi coesiva em camada h?brida. Na an?lise zimogr?fica, as enzimas foram caracterizadas como metaloproteinases da matriz, pois a sua express?o foi inibida pelo EDTA (um conhecido inibidor de MMPs), enquanto o NEM (um inibidor de proteases serinas) n?o teve nenhum efeito sobre a atividade enzim?tica. A MMP identificada no estudo, foi caracterizada como MMP-2, apresentando um peso molecular de 62KDa. A solu??o ?cida experimental apresentou um percentual de inibi??o da atividade gelatinol?tica de 93.66% (concentra??o de 0.05%) e de 58.58% (concentra??o de 0.01%), enquanto que a solu??o experimental teve um percentual de inibi??o de 31.28% e 6.83%, respectivamente. Com base nos resultados encontrados ? poss?vel concluir que ap?s 12 meses de armazenagem, o sistema adesivo Adper SE mostrou desempenho superior ao Adper SMP no teste de RUM, parecendo tamb?m ser mais efetivo na manuten??o da integridade da interface adesiva, sob an?lise fractogr?fica; e que a solu??o ?cida experimental condicionadora de superf?cie dentin?ria foi capaz de inibir quase completamente a atividade enzim?tica da MMP-2, de uma maneira dose dependente.
38

Efeito da vibra??o s?nica e ultrass?nica em um adesivo autocondicionante e de frasco ?nico na resist?ncia de uni?o em dentina

Cavazzola, Fernanda de C?ssia Mortari 11 March 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:22Z (GMT). No. of bitstreams: 1 447882.pdf: 1769645 bytes, checksum: 707e21b20055331c157549faf714a8c0 (MD5) Previous issue date: 2013-03-11 / Purpose: Investigate the influence of bonding systems application activated through a sonic and ultrasonic vibration and a sonic prototype on micro-tensile bond strength in dentin. Materials and Methods: Twenty-four extracted caries-free intact human molar teeth were embedded in a self-cured acrylic resin. The enamel was removed, using wet 220-, and 600-grit abrasive papers. Each adhesive system (self-etching primer and a single bottle total etch) was applied according to the manufacturer's instructions. Then, the groups were classified according to the type and method of application of bonding systems. After the adhesive technique, resin composite was condensed and light-cured for 20s. Afterwards, all specimens were completely included in a self-cured acrylic resin to stabilize the restorative material and the adhesive interface for the serial sections in a cutting machine. These cylinders were stored in distilled water at room temperature 37?C for 24h. The specimens were stressed in the interface between the composite and the dental surface until fracture occurred. The values were recorded in MPa, and submitted to statistical analysis. Data were submitted to Kolmogorov-Smirnov normality test. Two-way ANOVA and Tukey s Test for pairwise multiple comparisons were used (p<0.05). The failure modes were recorded in percentages.Results: The micro tensile bond strengths with sonic vibration were higher than the other groups, showing statistically significant differences. The sonic, ultrasonic and prototype group had more cohesive failure in resin compared to the control group, which had more cohesive failures of the hybrid layer. Conclusion: The application with a sonic vibration is an effective method for the optimization of bond strength in dentin / Objetivo: Verificar se a aplica??o dos sistemas adesivos, por meio da vibra??o do aparelho s?nico, ultrass?nico e de um prot?tipo s?nico aumenta a resist?ncia de uni?o em dentina. A hip?tese experimental ? que a resist?ncia de uni?o nos sistemas adesivos Adper Single Bond 2 e Clearfill SE Bond ? similar tanto nos grupos controle quanto nos grupos que receberem os diferentes tratamentos. Materiais e M?todo: Foram utilizados 24 terceiros molares h?gidos, onde foi realizada a remo??o do esmalte preparando uma superf?cie dentin?ria lisa. Os dentes foram divididos aleatoriamente em 8 grupos, onde cada sistema adesivo foi aplicado de acordo com as recomenda??es do fabricante (aplica??o din?mica manual) e com a vibra??o de aparelho s?nico , ultrass?nico e por um prot?tipo s?nico. Ap?s a t?cnica adesiva, foi aplicada resina charisma A2. As amostras foram inclu?das em resina acr?lica autopolimeriz?vel, preparando um cilindro para os cortes seriados. Estes foram armazenados em ?gua destilada em uma estufa de cultura a 37?C por 24 horas. Ap?s, confeccionou-se os corpos de prova em forma de barra para o ensaio de resist?ncia de uni?o por microtra??o. Os dados obtidos foram submetidos ao teste Kolmogorov-Smirnov para verifica??o de normalidade.A seguir, foram comparados com ANOVA de duas vias e teste de Tukey (p=0,05). A an?lise da fractografia foi realizada porcentualmente. Resultados: A resist?ncia de uni?o do grupo que recebeu a vibra??o s?nica foi maior, apresentando diferen?as estatisticamente significativas, em ambos os sistemas adesivos, comparada com aplica??o din?mica manual e os grupos que receberam tratamento ultrass?nico e do prot?tipo s?nico. Na an?lise fractografia observa-se que os grupos que receberam tratamento s?nico, ultrass?nico e do prot?tipo tiveram maior falha coesiva em resina em rela??o ao grupo controle, que obteve maiores falhas coesivas de camada h?brida. Conclus?o: A utiliza??o da aplica??o s?nica, ? um m?todo eficaz para a otimiza??o da resist?ncia de uni?o em dentina
39

Avalia??o cl?nica de restaura??es indiretas em resina composta cimentadas com material resinoso convencional e autoadesivo

Marcondes, Maurem Leit?o 28 March 2014 (has links)
Made available in DSpace on 2015-04-14T13:30:33Z (GMT). No. of bitstreams: 1 458471.pdf: 1434696 bytes, checksum: 1b82056bbee62d1935b0803e571f0c64 (MD5) Previous issue date: 2014-03-28 / The aim of this study was to clinically evaluate the performance of indirect composite resin restorations cemented with conventional and self-adhesive resin cement, during a 12-month period. Twenty-four composite resin restorations were performed through indirect technique and cemented with two resin cements: a conventional (RelyX ARC) and a self-adhesive (RelyX U100). Two independent evaluators analyzed the restorations using the criteria of the USPHS (United States Public Health Service) modified after two weeks, six months and 12 months. For the analysis of data from USPHS, between the cements at the same time, it was used the Wilcoxon statistical test and for evaluation at different times, it was used the Mann-Whiney test, at significance level of 5 %. The Fisher exact test was used to assess the occurrence of absolute failures. No statistically significant differences were found between groups in the same period and between groups at different times, one statistical difference was found only for the criteria color match. We conclude that indirect composite resin restorations cemented with self-adhesive resin cement showed a similar performance of restorations cemented with conventional resin cement after a year of analysis. / O objetivo deste estudo foi avaliar clinicamente o desempenho de restaura??es indiretas de resina composta cimentadas com cimento resinoso convencional e autoadesivo no per?odo de 12 meses. Foram realizadas 24 restaura??es em resina composta (Filtek Supreme XT), executadas pela t?cnica indireta e cimentadas com dois cimentos resinosos: um convencional (RelyX ARC) e um autoadesivo (RelyX U100). Dois avaliadores independentes analisaram as restaura??es atrav?s dos crit?rios do USPHS (United States Public Health Service) modificado ap?s duas semanas, seis meses e 12 meses. Para a an?lise dos dados do USPHS, entre os cimentos no mesmo tempo, foi utilizado o teste estat?stico de Wilcoxon e, para avalia??o nos diferentes tempos, o Mann-Whiney ao n?vel de signific?ncia de 5%. O teste exato de Fisher foi usado para avaliar a ocorr?ncia de falhas absolutas. N?o foram encontradas diferen?as estatisticamente significativas entre os grupos no mesmo per?odo e entre os grupos nos diferentes tempos, havendo diferen?a estat?stica apenas para o crit?rio combina??o de cor. Pode-se concluir que restaura??es de resina composta indireta cimentadas com cimento resinoso autoadesivo tiveram um desempenho similar ?s cimentadas com cimento resinoso convencional ap?s um ano de avalia??o.
40

Avalia??o da precis?o dos modelos de gesso obtidos por diferentes t?cnicas de moldagem para pr?teses m?ltiplas implanto suportadas

Becker, Anne Buss 09 May 2014 (has links)
Made available in DSpace on 2015-04-14T13:30:35Z (GMT). No. of bitstreams: 1 459308.pdf: 2403047 bytes, checksum: 9f617311a86d53fd907e33dfdebe0f05 (MD5) Previous issue date: 2014-05-09 / The aim of this study was to evaluate the accuracy of implants master casts obtained by pick- up techniques with an open custom tray using squared impression copings, using several union transfers on two, in vitro, experimental models. First, the dimensional accuracy of implants master cast was evaluated, and two impression techniques: G1- squared impression copings (S) and G2- splinted squared copings, using dental floss and acrylic resin for implant-supported prostheses. An aluminum block with 2 implant-abutment analogs were fabricated (one implant was made at right angle to the top surface A and the other was angulated 65 degrees sideway B and a frameworks in type NiCr was used. Impression was performed using acrylic resin tray and polyether impression material. Specimens were divided in two experimental groups: squared impression copings (S) and splinted squared copings. Five casts were made per group, in total of 10 casts. A software was used in order to analyze and to record the vertical gap between reference framework and analogs in duplicate casts, connected to a stereomicroscope. Results showed statistical differences between group 1 and 2, with lower levels of gaps in the splinted squared copings, using dental floss and acrylic resin compared to the squared impression copings (P=.021). On the implant evaluation, higher values were obtained for the implant angulated 65 degrees with squared impression copings technique (P=.013). A aluminum block with 2 parallel implant-abutment analogs were fabricated, in order to evaluated the accuracy of implants master cast, poured with die stone (GC Fujirock EP; GC Europe, Leuven, Belgium and Dentona AG, Europe, Dortmund, Germany) using 3 different impression techniques and two differents commercial trademarks of stone, compared to a control group. Polyether impression material was used for all impression with acrylic resin tray. Seven groups were formed: G1 control group; G2a Squared impression copings, poured with a die stone GC Fujirock EP; G2b Squared impression copings, poured with a die stone Zero Stone G3a Splinted squared copings using dental floss and acrylic resin poured with a die stone GC Fujirock EP; G3b- Splinted squared copings using dental floss and acrylic resin - poured with a die stone Zero Stone; G4a - Splinted squared copings using dental floss and bisacrilica resin - poured with a die stone GC Fujirock EP; G4b - Splinted squared copings using dental floss and bisacrilica resin poured with a die stone Zero Stone. The distances between the analogs of each specimen were measured, using a software, connected to the stereomicroscope. Results presented statistical differences between the distances of G1 and G2a (p=0.010), G2b (p=0.015), G4b (p=0.007). No statistical differences were found between G1 and G3a (p=0.178), G3b (p=0.288), G4a (p=0.531). Splinted squared copings poured with a die stone GC Fujirock EP produced cast most similar to the control Group. In conclusion, the accuracy of the SS impression technique was superior to squared impression copings (S), for implants presenting different angulation; the inaccuracy seen with the squared impression copings (S) method seemed to correlate with the nonparallel (< 65?) abutment relationship and the apparent deformation of the impression material / O objetivo deste estudo foi avaliar a precis?o dos modelos de gesso sobre implantes obtidos por meio da t?cnica de moldagem de arrasto, na qual utiliza transferentes quadrados, utilizando diferentes materiais para uni?o dos transferentes por meio de dois modelos experimentais in vitro. Inicialmente avaliou-se a precis?o dos modelos de gesso obtidos por meio de duas diferentes t?cnicas de moldagem: Grupo 1 Moldagem de arrasto sem uni?o dos transferentes e Grupo 2 Moldagem de arrasto com uni?o dos transferentes em resina acr?lica autopolimerizavel para pr?teses implanto suportadas. Um bloco de alum?nio com 2 an?logos do implante minipilar 4.1 (Neodent SA Curitiba, Parana, Brasil) foi fabricado, sendo um analogo posicionado em angulo reto com o topo da superficie e outro inclinado a 65 graus lateralmente. Uma infraestrutura em liga NiCr, foi fabricada. As moldagens foram realizadas com moldeira individual em resina acrilica e o material utilizado foi o polieter. Dois grupos foram formados: Grupo 1 sem uni?o e Grupo 2 com uni?o em resina acrilica. Foram obtidos 5 modelos de gesso por grupo totalizando 10 modelos. A dist?ncia entre a infraestrutura e os analogos foi mensurada (gap vertical) por meio do programa (AxionVision 4.8.1, Zeiss; Carl Zeiss, Jena, Germany) acoplado a lupa estereomicroscopia. Os resultados mostraram diferen?as significantes entre os grupos 1 e 2, com menores valores de gap para o grupo com uni?o em resina acrilica (p=0,021). Na avalia??o por implante, maiores valores foram obtidos para implantes inclinados (65 graus lateralmente) pela tecnica sem uni?o (p=0,013). Posteriormente, um bloco de alum?nio com dois implantes paralelos foi fabricado e foi investigado a precis?o dos modelos de gesso obtidos por meio de tr?s diferentes t?cnicas de moldagem e duas diferentes marcas comercias de gesso tipo IV (A - Fujirock EP; GC Europa, Leuven, Belgica e B - Zero Stone; Dentona AG, Europa, Dortmund, Alemanha), comparados com um grupo controle (bloco de alum?nio com dois an?logos do implantes minipilar 4.1 paralelos entre si). O material utilizado para as moldagens foi o poli?ter. Sete grupos foram formados: G1 grupo controle, G2a sem uni?o e gesso Fujirock, G2b sem uni?o e gesso Zero Stone, G3a uni?o com resina acrilica e gesso Fujirock, G3b uni?o com resina acrilica e gesso Zero Stone, G4a - uni?o com resina bisacrilica e gesso Fujirock, G4b - uni?o com resina bisacrilica e gesso Zero Stone. Foram avaliadas as distancias entre os implantes por meio do programa (AxionVision 4.8.1, Zeiss; Carl Zeiss, Jena, Germany) acoplado a lupa estereomicroscopia. Os resultados mostraram diferen?as significante entre as distancias do G1 - grupo controle e os grupos: G2a - sem uni?o e gesso Fujirock (p=0.010), G2b- sem uni?o e gesso Zero Stone (p=0.015) e G4b - uni?o com resina bisacrilica e gesso Zero Stone. (p=0.007). N?o houve diferen?as significantes entre o G1 - grupo controle e os grupos G3a - uni?o com resina acrilica e gesso Fujirock (p=0.178), G3b- uni?o com resina acrilica e gesso Zero Stone (p=0.288), G4a - uni?o com resina bisacrilica e gesso Fujirock (p=0.531). Conclui-se que os grupos sem uni?o dos componentes produziram maiores distor??es quando comparadas ao grupo controle. Em conclus?o, a moldagem sem uni?o dos transferentes, apresentou maiores distor??es. A desadapta??o entre infraestrutura e an?logo com a t?cnica sem uni?o parece estar correlacionada com a aus?ncia de paralelismo dos implantes dent?rios.

Page generated in 0.2824 seconds