Spelling suggestions: "subject:"ditadura"" "subject:"dictadura""
111 |
Comparación en la resistencia a la fractura del sistema espiga-muñón de fibroresina entre dientes con remanencia de paredes opuestas proximales vs. caras libres restaurados con provisorios de acrílico mejorado de autopolimerización : (in vitro))Balmaceda Mengozzi, Rocío Davinia January 2016 (has links)
Trabajo de Investigación Requisito para optar al Título de Cirujano Dentista / Introducción
Los dientes tratados endodónticamente con extensa destrucción coronaria se
pueden rehabilitar empleando un sistema espiga-muñón. Durante los últimos años
se ha incrementado el uso de postes prefabricados debido a sus buenas
propiedades mecánicas, especialmente los de fibra de vidrio que, además, brindan
buena estética. Diversos estudios establecen que a mayor cantidad de dentina
remanente el diente tendrá mayor resistencia a la fractura. Eventualmente un
diente puede conservar sólo dos paredes coronales en posición opuesta. Este
estudio determinó y comparó la resistencia a la fractura del sistema espiga-muñón
de fibroresina entre dientes con remanencia de paredes opuestas proximales vs.
caras libres restaurados con provisorios de acrílico mejorado de
autopolimerización (in vitro).
Materiales y métodos
Se seleccionaron 30 dientes anteriores humanos recientemente extraídos a
los cuales se les realizó tratamiento endodóntico y posterior desobturación parcial
de 2/3 del canal radicular. Se les hizo un tallado periférico tipo chamfer a nivel de
límite amelo-cementario, dejando las paredes remanentes de corona de 1 mm de
grosor aproximado. Fueron clasificados al azar en tres grupos de 10 dientes cada
uno: grupo A (control, conservó cuatro paredes coronarias), grupo B (se eliminaron
paredes vestibular y palatina/lingual) y grupo C (se eliminaron paredes mesial y
distal). Los canales radiculares fueron preparados para cementar un poste de fibra
de vidrio con cemento de resina autoadhesivo. Se reconstruyeron los muñones
con resina. A cada diente se fabricó un provisorio de 1 mm de grosor con acrílico
mejorado de autopolimerización. Cada diente recibió carga de una máquina
Instron hasta fracturarse, con una inclinación de 130° respecto del eje mayor del
diente. Se utilizaron los tests Shapiro-Wilk y ANOVA para análisis estadístico.
Resultados
La media de resistencia a la fractura en los grupos de dientes A, B y C fue de
526 N, 487 N y 485 N respectivamente, no habiendo diferencia estadísticamente
significativa entre sí. Además, la mayoría de las fracturas fue de tipo irreparable.
Conclusiones
La posición de las paredes opuestas coronarias, ya sean de caras libres o
proximales, no tiene importancia en la resistencia a la fractura del diente, si se
rehabilita con poste de fibra de vidrio y provisorio acrílico. Tampoco tiene
significancia el número de paredes remantes del muñón, si son dos o cuatro,
estando cubiertas por un provisorio de acrílico. / Adscrito a Proyecto PRI-ODO 14/009
|
112 |
Evaluación clínica de 6 meses de restauraciones clase i de resina compuesta en la clínica docente UPCArnáez Talavera, Daniela 03 November 2016 (has links)
Objetivo: Evaluar el comportamiento clínico de las resinas compuestas clase I realizadas por alumnos de pregrado en la Clínica Docente UPC después de 6 meses. Materiales y métodos: Se evaluaron, luego de 6 meses, 47 resinas Clase I. Se utilizó la metodología USPHS, describiendo el color, adaptación marginal, rugosidad, tinción marginal, forma anatómica y caries secundaria mediante la codificación Alfa, Bravo y Charlie, es decir, restauraciones en condición excelente, aceptable e inaceptable respectivamente. Resultados: Los pacientes fueron contactados a los 6 meses de haber realizado las restauraciones Clase I. Se encontró que el 100% de las restauraciones se mantuvieron iguales. Al no presentarse variación alguna durante ese periodo, se concluye que tanto en la medida del baseline como en la comparativa a los 6 meses se obtuvo Alfa al 100% (n = 47) para el color, adaptación marginal, rugosidad, tinción marginal y caries secundaria; y se obtuvo Alfa al 87.23% (n = 41) y Bravo al 12.77% (n = 6), para la forma anatómica. Conclusión: Para la evaluación clínica de 6 meses de restauraciones Clase I de resina compuesta, las restauraciones mantuvieron el 100% de similitud durante ese periodo de tiempo, es decir tanto en la medida del baseline como en la comparativa. / Objective: The aim of this study was to evaluate the clinical performance Class I composites performed by undergraduate students at the Teaching Clinic UPC after 6 months. Material and Methods: A total of 47 class I restorations were clinically evaluated 6 months after placement, using USPHS criteria, describing color match, marginal adaptation, roughness, marginal staining, anatomy and secondary caries. Alpha, Bravo and Charlie where the coding, being excellent restorations, acceptable and unacceptable condition respectively. Results: At the 6-month follow-up, all restorations received the same initial scores with respect to each evaluation criterion. Color match, marginal adaptation, roughness, marginal staining and secondary caries scored Alfa at 100% (n = 47), and anatomical shape scored Alfa at 87.23 % (n = 41) and Bravo at 12.77 % (n = 6). Conclusion: All composites were clinically functional after 6 month and received the same initial scores with respect to each evaluation criterion. / Tesis
|
113 |
Calidad del diseño de los componentes de la prótesis parcial removible base metálica en modelos de trabajo en un laboratorio dental de la ciudad de Chiclayo, 2014Agurto Rodríguez, Rodolfo Yunior, Coronado Falen, Martin Manuel, Herrera Paz, Luis Fernando January 2015 (has links)
El propósito de la presente investigación fue determinar la calidad del diseño de los componentes de la Prótesis Parcial Removible (PPR) de base metálica en modelos de trabajo en un laboratorio dental de la ciudad de Chiclayo. El diseño de la investigación es de tipo descriptivo, participaron el total de modelos de trabajo que se recepcionaron en un laboratorio dental, representados con un grupo de estudio de 85 modelos. Se aplicó un instrumento evaluativo que sirvió para la evaluación del diseño de los componentes de la PPR y una ficha de recolección de datos. Los valores obtenidos se analizaron mediante estadística descriptiva, frecuencias y porcentajes. Los resultados evidenciaron que el 51.76 % del diseño de apoyos fue ejecutado de forma correcta, Los retenedores fueron diseñados correctamente en un 50.59%, los conectores mayores en un 41.18%, los conectores menores 47.06 %, mientras que el diseño de las bases fueron ejecutados de manera correcta en un 70.59 %. Se concluyó que los componentes de la PPR diseñados fueron en su mayor porcentaje incorrectos, evidenciando un déficit en el diseño de PPR por parte del Cirujano Dentista. Se recomienda constante capacitación y apoyo de las instituciones, de esta manera fortalecer conocimientos y destrezas en este campo tan descuidado de la rehabilitación oral.
|
114 |
Relación entre el grado de satisfacción de los pacientes rehabilitados con prótesis total y la calidad de la prótesis, en el Centro Especializado en Formación Odontológica de la Universidad Católica Santo Toribio de Mogrovejo de Chiclayo, 2016Flores Rivera, Gaby Fiorella, Nuñez Jimenez, Breigy Aranza January 2018 (has links)
El propósito de esta investigación fue evaluar la relación entre el grado de satisfacción de los pacientes rehabilitados con prótesis total y la calidad de la prótesis, en el Centro Especializado en Formación Odontológica de la Universidad Católica Santo Toribio de Mogrovejo de Chiclayo, 2016. El diseño del estudio fue de tipo analítico, observacional y transversal. La población de estudio fue de 52 pacientes que cumplieron con los criterios de inclusión y exclusión. Los instrumentos para la evaluación de las variables del estudio fueron: ficha de recolección de datos, cuestionario de Perfil de impacto de la salud oral en pacientes desdentados (OHIP-EDENT-Sp) y una ficha evaluativa de prótesis total. Los pacientes portadores de prótesis total mostraron estar satisfechos (88.5 %) y poco satisfechos (11.5%). También se evidenció que la calidad en las prótesis fue buena (13.5%), regular (76.9%) y mala (9.6%). La mayoría de pacientes satisfechos son los portadores de prótesis de regular calidad (69.2 %). Se concluyó que no existe relación entre la satisfacción y calidad de la prótesis mediante la prueba Chi-cuadrado (p-valor= 0.083).
|
115 |
Capacidade de remoção de biofilme e ação antimicrobiana de soluções químicas na higienização de próteses totais e escovas específicas / Ability of biofilm removal and antimicrobial action of chemical solutions in the hygiene of dentures and specific brushesArruda, Carolina Noronha Ferraz de 24 May 2018 (has links)
Este estudo clínico randomizado avaliou o efeito de soluções químicas, quanto à remoção de biofilme e ação antimicrobiana, na higienização das próteses totais superiores e escovas específicas. Quarenta e cinco participantes foram orientados a escovar suas próteses (escova específica para prótese e sabonete neutro) três vezes ao dia e imergí-las, uma vez ao dia, nas soluções: Grupo I- Solução salina (controle negativo); Grupo II- Hipoclorito de sódio 0,2% (controle positivo); Grupo III- Peróxido Alcalino (Efferdent® Power Clean Crystals); Grupo IV- Ricinus communis a 6,25%. Além disso, os participantes também foram randomizados para a imersão (n=23) ou não imersão (n=22) das escovas específicas nas soluções, juntamente às próteses, para avaliação das escovas quanto à ação antimicrobiana e degradação das cerdas. As avaliações foram realizadas antes (Baseline) e após os 7 dias de uso de cada solução. Para a remoção de biofilme, as próteses foram evidenciadas (vermelho neutro 1%), fotografadas e a área de biofilme foi mensurada (Image Tool 3.00). A ação antimicrobiana foi avaliada por meio da contagem de Candida spp. e Streptococcus mutans. Para coleta do biofilme das próteses, as mesmas foram escovadas (escova Tek e solução salina) por 2 minutos, sendo a suspensão transferida para tubos de ensaio. As escovas foram preparadas, colocadas em meio de cultura Letheen Broth (20 mL) e levadas para cuba ultrassônica, seguido de agitação mecânica e centrifugação (6000 rpm, por 7 minutos). Diluições decimais (100 até 10-3) com alíquotas (50 L) de cada diluição foram cultivadas em placas de Petri contendo meio de cultura adequado, para posterior incubação (aerobiose) por 48hs e contagem do número de colônias. As diferenças entre imersão ou não imersão da escova foram avaliadas pelo teste de Mann-Whitney (α=0,05). As propriedades de remoção de biofilme e ação antimicrobiana foram avaliadas pelo teste de Friedman, seguido pelo teste de Wilcoxon (α=0,05). Os resultados mostraram que, para a propriedade de remoção de biofilme, em ambos os grupos (com e sem imersão da escova), as soluções de hipoclorito de sódio a 0,2% [com imersão: posto-médio (PM)=1,41; sem imersão: PM=1,48], Efferdent® (com imersão: PM =2,41; sem imersão: PM =2,25) e Ricinus communis a 6,25% (com imersão: PM=2,48; sem imersão: PM=2,77) foram eficazes e semelhantes (p<0,001). Para as próteses, foi verificada ação antimicrobiana frente a Candida spp. para todas as soluções (hipoclorito de sódio a 0,2%: com imersão PM=2,22, sem imersão PM=2,09; Efferdent®: com imersão PM=2,24, sem imersão PM=2,57; Introdução | 22 Ricinus communis a 6,25%: com imersão PM=2,20, sem imersão PM=2,75). Frente a S. mutans, as soluções de hipoclorito de sódio a 0,2% (com imersão: PM=2,13, sem imersão: PM=1,96) e Efferdent® (com imersão: PM=2,26, sem imersão: PM=2,18) foram as mais eficazes e a solução de Ricinus communis a 6,25% (com imersão: PM=2,39, sem imersão: PM=2,75) apresentou valores intermediários (p<0,001). Não houve diferença significante na contagem UFC/mL de Candida spp. para as escovas, tanto para o grupo que não realizou a imersão das escovas (p=0,108), como para os que realizaram o procedimento (p=0,467). Para S. mutans, não houve diferença significante entre as soluções (p<0,001) para o grupo que não realizou a imersão das escovas, enquanto que para o grupo com imersão da escova o Efferdent e hipoclorito de sódio a 0,2% mostraram redução na contagem UFC/mL de S. mutans quando comparado ao grupo Controle (p=0,001). A solução de Ricinus communis a 6,25% apresentou valores intermediários. As imagens em microscopia eletrônica mostraram grande deterioração das cerdas após 7 dias de uso, e a solução de hipoclorito de sódio promoveu um maior número de ranhuras nas cerdas quando imersas. Concluiu-se que todas as soluções foram efetivas na remoção do biofilme e frente a Candida spp., no entanto, frente a S. mutans, as soluções de hipoclorito de sódio a 0,2% e Efferdent® foram efetivas, enquanto a solução de Ricinus communis a 6,25% promoveu ação intermediária. Em relação as escovas, não houve diferença entre os grupos em relação ao protocolo de imersão e na redução de UFC/mL de Candida spp. e S. mutans / This randomized clinical study evaluated the effect of chemical hygiene solutions on biofilm removal and antimicrobial action of denture and specific brushes. Forty-five participants were instructed to brush their dentures (specific brush and liquid soap) three times a day and to soak them, once a day, in the solutions: Group I- Saline solution (negative control); Group II - Sodium hypochlorite 0.2% (positive control); Group III - Alkaline Peroxide (Efferdent® Power Clean Crystals); Group IV Ricinus communis 6.25%. In addition, the participants were also randomized to immersion (n=23) or non-immersion (n=22) of the specific brushes in the solutions, with the dentures, to evaluate the brushes for antimicrobial action and bristle degradation. Evaluations were performed before (Baseline) and after 7 days of use of each solution. For the biofilm removal, the dentures were disclosed (1% neutral red), photographed and the biofilm area was measured (Image Tool 3.00). The antimicrobial action was evaluated by counting Candida spp. and Streptococcus mutans. To collect denture biofilm, dentures were brushed (Tek brush and saline solution) for 2 minutes, and the suspension transferred to test tubes. The brushes were prepared and placed at Letheen Broth (20 mL) and taken to ultrasonic vessel, followed by mechanical shaking and centrifugation (6000 rpm for 7 minutes). Decimal dilutions (100 to 10-3) with aliquots (50 L) of each dilution were grown in Petri dishes containing suitable culture medium, for further incubation (aerobiose) for 48 h and counting the number of colonies. The differences between brushes immersion or non-immersion by the Mann-Whitney test (α=0.05). The properties of biofilm removal and antimicrobial action were evaluated by Friedman test, followed by the Wilcoxon test ( α= 0.05). The results showed that, for the biofilm removal property, in both groups (brush immersion or non-immersion), 0.2% sodium hypochlorite [immersion: Mean-Rank (MR)=1.41; non-immersion: MR=1.48], Efferdent® (immersion: MR=2.41, non-immersion: MR=2.25) and 6.25% Ricinus communis (immersion: MR=2.48; non-immersion: MR=2.77) were effective and similar (p <0.001). For dentures, was founded antimicrobial action against Candida spp. for all solutions (0.2% sodium hypochlorite: immersion: MR=2.22, non-immersion: MR=2.09; Efferdent ®: immersion: MR=2.24, non-immersion: MR=2.57; 6.25% Ricinus communis: immersion: MR=2.20, non-immersion: MR=2.75). Against S. mutans, 0.2% sodium hypochlorite (immersion: MR=2.13, Introdução | 26 non-immersion MR=1.96) and Efferdent® (immersion: MR=2.26, non-immersion: MR=2.18) were the most effective and 6.25% Ricinus communis (immersion: MR=2.39, non-immersion: MR=2.75) showed intermediate values. There was no significant difference in the brushes CFU/mL of Candida spp. for group that did not perform brush immersion (p=0.108), as well as for those who performed the procedure (p=0.467). For S. mutans, there was no significant difference between the solutions (p <0.001) for the group that did not immerse the brushes, whereas for the brush-immersion group, Efferdent and 0.2% sodium hypochlorite showed a reduction in the UFC / mL count of S. mutans when compared to the Control group (p=0.001). 6.25% Ricinus communis presented intermediate values. The electron microscopy images showed a great deterioration of the bristles after 7 days of use, and the sodium hypochlorite solution promoted a greater number of grooves in the bristles. It was concluded that all solutions were effective for biofilm removal and Candida spp.. However, for S. mutans 0.2% sodium hypochlorite and Efferdent® were effective, whereas 6.25% Ricinus communis showed intermediate action. Regarding the brushes, there was no difference between the groups in relation to the immersion protocol and in the reduction of CFU/mL of Candida spp. and S. mutans
|
116 |
Avaliação in vitro da suscetibilidade de biofilme multiespécies às soluções de peróxidos / In vitro evaluation of the susceptibility of multispecies biofilms to peroxides solutionsCoimbra, Flávia Cristina Targa 26 June 2018 (has links)
O objetivo desse estudo in vitro foi avaliar a efetividade antimicrobiana de higienizadores à base de peróxidos frente a biofilme multiespécies e o impacto dessas soluções na redução da carga microbiana, atividade metabólica e do biofilme agregado. A partir de matrizes circulares metálicas (15 x 3 mm), foram confeccionados corpos de prova de resina acrílica termopolimerizável os quais foram esterilizados em micro-ondas (650W, por 6 minutos) e inoculados com suspensão de 105 UFC/mL de Candida albicans (Ca) e 106 UFC/mL de Staphylococcus aureus (Sa) e de Pseudomonas aeruginosa (Pa). Após contaminação, os corpos de prova foram incubados a 37 ºC por 20 h e, em seguida, por meio de uma cesta de aço inoxidável, foram imersos em Béquer com as seguintes soluções, de acordo com as instruções do fabricante (n=9): Grupo CP (Controle positivo) - imersão em PBS (Phosphate-Buffered Saline); Grupo MI NitrAdine e Grupo FX Fixodent. Em seguida, foram lavados (PBS) e imersos em meio de cultura Letheen, para a avaliação da esterilidade e obtenção de diluições seriadas (100 a 10-3), as quais foram semeadas em meios de cultura específicos: CHROMagar Candida para C. albicans, Manitol Salt Agar para S. aureus e Agar Cetrimide para P. aeruginosa. Após incubação, de acordo com morfologia típica, o número de colônias características foi mensurado e o número de UFC/mL calculado. A avaliação da atividade metabólica foi realizada pelo método de redução do XTT e a viabilidade celular foi avaliada por microscopia de epifluorescência (n=2). Os dados obtidos para as variáveis de UFC/mL (Sa e Pa), Unidades de Absorbância e Percentual de Área, foram avaliados pelo teste de Kruskal-Wallis, seguido pelo teste de Dunn (=0,05). Para comparação entre os dados vinculados (Percentual de área de células vivas e totais) empregou-se também o teste de Wilcoxon. Os dados da variável de UFC/mL para C. albicans foram avaliados pelo teste de ANOVA e pós-teste de Tukey, uma vez que apresentaram distribuição normal. Os resultados de UFC/mL mostraram diferença significativa entre os grupos (Ca p=0,002, Pa p<0,001e Sa p<0,001) havendo redução significante do número de UFC/mL de C. albicans [MI: 2,13 (1,17)], de P. aeruginosa [FX: 2,96 (1,76 4,17) e MI: 0,00 (-0,43 2,06)] e S. aureus [FX: 3,59 (2,97 4,31) e MI: 1,90 (0,40 3,01)], quando comparado aos grupos controles [CP:Ca: 4,02 (0,85), CP:Pa: 6,43 (6,02 6,61) e CP:Sa: 5,67 (5,41 6,31)]. Houve redução da atividade metabólica do biofilme multiespécies (p<0,001), em ambas as soluções higienizadoras [FX: 0,001 (-0,006 0,058) e MI: 0,000 (- 0,002 0,066)] quando comparadas ao Grupo Controle [CP: 0,068 (0,046 0,190)]. As imagens da microscopia de epifluorescência revelaram redução significativa da área de biofilme agregado sobre os corpos de prova após a imersão nos higienizadores [FX: 85,19 (77,23 86,42) e MI: 78,42 (70,91 81,65)] quando comparados ao grupo controle (p<0,001). Na comparação entre as áreas de biofilme vivo e total pode-se observar diferenças entre as áreas do biofilme multiespécies (p<0,001), após a imersão nos higienizadores avaliados. Conclui-se que os higienizadores de prótese conseguiram reduzir a atividade metabólica bem como o biofilme agregado, embora nenhum higienizador tenha conseguido remover completamente o biofilme multiespécies. O higienizador NitrAdine foi o mais efetivo na redução da carga microbiana do biofilme multiespécies. A P. aeruginosa foi mais suscetível a ação dos higienizadores do que o S. aurueus e C. albicans, quando associada em biofilme multiespécies / The objective of this in vitro study was to evaluate the peroxides soluions antimicrobial effectiveness of against the viability of multispecies biofilm and the impact of these solutions on the reduction of microbial load, metabolic activity and biofilm aggregate. Acrylic resin specimens were obtained by a circular metal matrix (15 × 3 mm), sterilized with microwave irradiation (650 W, 6 min) and contaminated with contaminated with 105 CFU/mL suspension of Candida albicans (Ca) and 106 CFU/mL suspensions of Staphylococcus aureus (Sa) and Pseudomonas aeruginosa (Pa). After contamination, the specimens were incubated at 37 ° C for 20 hours and then immersed in Becker through a stainless-steel basket, on the following solutions according to the manufacturer\'s instructions (n=9): Group CP (positive control) immersion in PBS (Phosphate-Buffered Saline); Group MI NitrAdine and Group FX - Fixodent. The specimens were washed (PBS) and immersed in Letheen culture medium, to evaluate sterility and obtain serial dilutions (100 to 10-3), that were seed into specific medium: CHROMagar Candida for C. albicans, Manitol Salt Agar for S. aureus and Agar Cetrimide for P. aeruginosa. After incubation, in accordance with characteristic morphology, the number of characteristic colonies was counted and the number of CFU/mL calculated. The evaluation of metabolic activity was performed by the XTT reduction assay and cell viability was evaluated by epifluorescence microscopy. The data obtained for the variables of CFU (Sa and Pa), Absorption Units and Area Percentage were evaluated by the Kruskal-Wallis test, followed by the Dunn test (=0.05). The Wilcoxon test was used to compare the paired data (percentage of live and total cell area). Data from the variable of UFC/mL for C. albicans were evaluated by the Anova test and Tukey\'s post-test, since they presented a normal distribution. The results of UFC/mL showed significant differences between groups (Ca p=0.002, Pa p<0.001e Sa p<0.001) with significant reduction in the number of CFU/mL of C. albicans [MI: 2.13 (1.17)], P. aeruginosa [FX: 2.96 (1.76 4.17); MI: 0.00 (-0.43 2.06)] and S. aureus [FX: 3.59 (2.97 4.31); MI: 1.90 (0.40 3.01)], when compared with control group [CP:Ca: 4.02 (0.85), CP:Pa: 6.43 (6.02 6.61) e CP:Sa: 5.67 (5.41 6.31)]. There was reduction in the metabolic activity of the multispecies biofilm in both denture cleanser [FX: 0.001 (-0.006 0.058) e MI: 0.000 (- 0.002 0.066)] when compared with control group [CP: 0.068 (0.046 0.190)]. The epifluorescence microscopy images revealed a significant reduction of the biofilm area on the specimens after immersion in the denture cleansers [FX: 85.19 (77.23 86.42) e MI: 78.42 (70.91 81.65)] when compared with control group (p<0.001). In live and total biofilm areas comparison it was possible to observe differences between the areas of the multispecies biofilm (p<0,001), after immersion in the denture cleansers evaluated. It was concluded that the denture cleansers were able to reduce metabolic activity as well as the aggregate biofilm, although none of the cleansers was able to completely remove the multispecies biofilm. NitrAdine was the most effective in reducing the microbial load of multispecies biofilm. P. aeruginosa was more susceptible to the action of denture clenasers than S. aureus and C. albicans, when associated with multispecies biofilms
|
117 |
Efeito da incorporação de agentes antifúngicos na resistência à tração e porosidade de materiais resilientes temporários para base de próteses / Effect of incorporation of antifungal agents on the ultimate tensile strength and porosity of temporary soft denture linersLima, Jozely Francisca Mello 10 February 2017 (has links)
Este estudo investigou a resistência à tração (ou limite de resistência à tração- LRT) e a porosidade de reembasadores resilientes temporários modificados por concentrações inibitórias mínimas (CIMs) de agentes antifúngicos para o biofilme Candida albicans (SC5314). Para os testes de LRT, corpos de prova em forma de halteres (n=7) com uma área transversal de 33 mm x 6 mm x 3 mm foram produzidos para os materiais resilientes (Trusoft e Softone) sem (controle) ou com incorporação de cinco fármacos em suas CIMs: nistatina- 0,032 g; diacetato de clorexidina- 0,064; cetoconazol- 0,128 g; miconazol- 0,256 g; itraconazol-0,256 g (grama de fármaco por grama de pó de material resiliente). Após a plastificação, as amostras foram imersas em água destilada a 37°C durante 24 h, 7 e 14 dias e, então, testadas em tensão em uma máquina universal de ensaios (EMIC DL-500 MF) a 40 mm/min. A porosidade foi mensurada por absorção de água, com base na exclusão do efeito plastificante. Inicialmente, determinou-se por isotermas de sorção, que a solução de armazenagem adequada para os corpos de prova (65 mm x 10 mm x 3,3 mm) de ambos os materiais foi o cloreto de cálcio anidro a 50% (S50). Assim, o fator de porosidade (FP) foi calculado para os grupos de estudo (n=10) formados por espécimes sem (controle) ou com incorporação de fármaco em suas CIMs (nistatina, clorexidina ou cetoconazol) após a armazenagem em água destilada ou S50 por 24 h, 7 e 14 dias. Os dados de resistência à tração (MPa) e percentagem de alongamento (%) foram submetidos à ANOVA de 3 fatores seguida pelo teste de Tukey (=0,05). Os dados de porosidade foram analisados estatisticamente por ANOVA de medidas repetidas para 4 fatores e teste de Tukey (=0,05). Ao final de 14 dias, a resistência à tração para ambos os materiais foi significativamente menor nos grupos modificados pelo miconazol e itraconazol em relação aos outros grupos (P<0,0001), que não mostraram diferenças significativas entre si (P>0,05). Após 7 e 14 dias em água, o miconazol e itraconazol adicionados a ambos os materiais resultaram em percentagens significativamente menores de alongamento em comparação com os outros fármacos e ao controle (P<0,0001), que foram semelhantes entre si (P>0,05). O cetoconazol não resultou em alterações significativas no FP para ambos os materiais resilientes em água ao longo de 14 dias (P>0,05). Em comparação aos controles, houve aumento dos FPs do Softone e Trusoft aos 14 dias de imersão em água somente após a adição de nistatina e clorexidina e de clorexidina, respectivamente (P<0,05). Ambos os materiais não apresentaram alterações significativas no FP em até 14 dias de imersão na S50, em comparação aos controles (P>0,05). Em todas as condições experimentais, os FPs do Softone e Trusoft foram significativamente menores quando imersos em S50 em comparação com a água destilada (P<0,05). Concluiu-se que a adição de nistatina, clorexidina e cetoconazol nas CIMs para o biofilme de C. albicans não resultou em efeitos deletérios na resistência à tração e na percentagem de alongamento dos materiais resilientes temporários para base de prótese até o período de 14 dias. A adição de antifúngicos nas CIMs não resultou em efeitos adversos à porosidade de ambos os materiais resilientes temporários em diferentes períodos de imersão em água, com exceção da clorexidina e nistatina no Softone e clorexidina no Trusoft aos 14 dias. Não foram observados efeitos deletérios para a porosidade de ambos os materiais resilientes modificados com as CIMs dos fármacos durante os 14 dias de imersão na S50. / This study investigated the tensile strength (ultimate tensile strength- UTS) and porosity of temporary soft denture liners modified by minimum inhibitory concentrations (MICs) of antifungal agents for Candida albicans biofilm (SC5314). For UTS tests, dumbbell-shaped specimens (n=7) with a central cross-sectional area of 33 mm x 6 mm x 3 mm were produced by resilient materials (Trusoft and Softone) without (control) or with incorporation of five drugs at MICs: nystatin- 0.032 g; chlorhexidine diacetate-0.064 g; ketoconazole- 0.128 g; miconazole- 0.256 g; itraconazole- 0.256 g (each per gram of soft liner powder). After plasticization, specimens were immersed in distilled water at 37°C for 24 h, 7 and 14 days, and then tested in tension in a universal testing machine (EMIC DL-500 MF) at 40 mm/min. The porosity was measured by water absorption, based on exclusion of the plasticizer effect. Initially, it was determined by sorption isotherms that the adequate storage solution for specimens (65 mm x 10 mm x 3.3 mm) of both materials was 50% anhydrous calcium chloride (S50). Then, the porosity factor (PF) was calculated for the study groups (n=10) formed by specimens without (control) or with drug incorporation at MICs (nystatin, chlorhexidine or ketoconazole) after storage in distilled water or S50 for 24 h, 7 and 14 days. Data of tensile strength (MPa) and elongation percentage (%) were submitted to 3-way ANOVA followed by Tukey\'s test (=0.05). Data of porosity were statistically analyzed by 4-way repeated measures ANOVA and Tukeys test (=0.05). At the end of 14 days, the tensile strength for both materials was significantly lower in the groups modified by miconazole and itraconazole compared to the other groups (P<0.0001), which showed no significant difference between them (P>0.05). After 7 and 14 days in water, miconazole and itraconazole added into both materials result in significant lower elongation percentages compared to the other drugs and control (P<.0001), which were similar to each other (P>0.05). Ketoconazole resulted in no significant changes in PF for both liners in water over 14 days (P>0.05). Compared to the controls, Softone and Trusoft PFs were increased at 14-day water immersion only after addition of nystatin and chlorhexidine, and chlorhexidine, respectively (P<0.05). Both materials showed no significant changes in PF in up to 14 days of S50 immersion, compared to the controls (P>0.05). In all experimental conditions, Softone and Trusoft PFs were significantly lower when immersed in S50 compared to distilled water (P<0.05). It was concluded that the addition of the nystatin, chlorhexidine and ketoconazole at MICs for C. albicans biofilm resulted in no harmful effects on the ultimate tensile strength and elongation percentage of the temporary soft denture liners up to 14-day period. The addition of antifungals at MICs resulted in no detrimental effects for the porosity of both temporary soft liners in different periods of water immersion, except for chlorhexidine and nystatin in Softone and chlorhexidine in Trusoft at 14 days. No deleterious effect was observed for the porosity of both soft liners modified by the drugs at MICs over 14 days of S50 immersion.
|
118 |
Efeito de soluções higienizadoras na retenção de cápsulas do tipo o\'ring / Effect of denture cleansers on the retention of capsules type o-ringPacheco, Thereza Cristina Lira 04 September 2015 (has links)
Soluções higienizadoras podem acarretar efeitos prejudiciais para as próteses, como deterioração da base da prótese e pigmentação. Porém, pouco se conhece sobre os efeitos destas na vida útil dos sistemas de retenção de uma overdenture. Deste modo, este estudo buscou avaliar se imersões diárias em clorexidina 2%, hipoclorito de sódio 1%, Corega® Tabs e água (controle) poderia acelerar a perda de retenção em attachments do tipo o´ring (S.I.N sistema de implantes®). Foram confeccionados 40 corpos de prova contendo cápsulas com anéis de borracha, simulando uma overdenture, e apenas 01 contendo o implante com o pilar o´ring. Eles foram separados em quatro grupos (n=10) e simulados noventa dias de imersões. Após, foram realizados testes de resistência à tração em uma máquina de ensaios mecânicos (MTS 810), antes e após a ciclagem com 270 ciclos, equivalentes a remoção e inserção da prótese três vezes ao dia, durante um período de três meses. Os resultados foram avaliados estatisticamente através dos testes ANOVA a dois critérios e do teste de Tukey (p≤0.05). Os valores médios (Newton) encontrados antes e após a imersão foram, respectivamente: Água - 9,482 / 6,081; Clorexidina - 9,972 / 7,390; Hipoclorito: 6,954 / 6,265 e Corega® Tabs: 12,464 / 11,121. Entre os grupos Clorexidina, Hipoclorito de sódio e Água não houve diferenças significativas. Houve diferenças estatisticamente significativas entre o grupo Corega® Tabs e os grupos controle e Hipoclorito de sódio, mas não com a Clorexidina. Assim, pôde-se concluir que soluções higienizadoras tiveram efeitos significativos na capacidade de retenção dos o´rings após o período simulado de três meses de imersão. / Denture cleansers can cause adverse effects on the prostheses, as deterioration of the denture base and pigmentation. However, little is known about its impacts on the life of an overdenture retention systems. Thus, this study sought to evaluate whether daily immersion in chlorhexidine 2%, sodium hypochlorite 1%, Corega® Tabs and water (control) would increase the retention loss in the O-ring type attachments (SIN implantes® system). Forty specimens containing capsules were made with rubber rings, simulating an overdenture, and only one containing the implant with the O-ring abutment. They were divided into four groups (n = 10) and ninety days in immersion were simulated, thereafter, conducted tensile strength tests on a testing machine (MTS - 810) before and after cycling of 270 cycles, equivalent to removal and insertion of the prosthesis three times a day for a period of three months. The results were statistically evaluated by the ANOVA two criteria and the Tukey test (p≤0.05). The mean values (Newton) found before and after immersion were: Water - 9,482 / 6,081; Chlorhexidine - 9,972 / 7,390; Hypochlorite: 6,954 / 6,265 and Corega® Tabs: 12.464 / 11.121. Among the groups chlorhexidine, sodium hypochlorite and water there were no significant differences. There were statistically significant differences between the group Corega® Tabs and controls and sodium hypochlorite groups, but not with the chlorhexidine. Thus, it concluded that denture cleansers had significant effects on retention capacity of orings after the simulated period of three months of immersion.
|
119 |
Efeito do etil-cianoacrilato (Super Bonder®) e do polidor líquido de baixa viscosidade (Biscover®) sobre biofilme de Candida albicans em resina acrílica para reembasamento / Effect of ethyl-cyanoacrylate (Super Bonder®) and a liquid polish of low viscosity (Biscover®) on Candida albicans biofilms on denture reline resinTávora, Flora Freitas Fernandes 10 July 2012 (has links)
A proposta desse trabalho foi verificar através de microscopia confocal de varredura a laser, se a utilização de uma resina fotopolimerizável de baixa viscosidade (Biscover®) e do etil-cianoacrilato (Super Bonder®) seriam eficientes em prevenir ou reduzir a formação de biofilme de Candida albicans. Cinqüenta e seis corpos de prova em resina acrílica para reembasamento (New Truliner) foram divididos aleatoriamente em 7 grupos: G1 (C)- Controle; G2 (SBAE)- Recebeu uma camada de Super Bonder® em sua superfície antes de esterilizar; G3 (SBDE)- Recebeu uma camada de Super Bonder® em sua superfície depois de esterilizar; G4 (SB3G)- 3 gotas de Super Bonder® incorporadas na resina; G5 (SB4G)- 4 gotas de Super Bonder® incorporadas na resina; G6 (BCDE)- Recebeu uma camada de Biscover® em sua superfície depois de esterilizar e G7 (BCAE) Recebeu uma camada de Biscover® em sua superfície antes de esterilizar. Todos os corpos de prova foram inoculados com Candida albicans para formação de biofilme. Os biofilmes remanescentes sobre os corpos de prova foram corados através dos fluorocromos SYTO-9 e iodeto de propídeo para análise no microscópio confocal. Os dados foram analisados através dos testes estatísticos de Kruskal-Wallis e Dunn, a um nível de significância de 5%. Os resultados obtidos pelo microscópio confocal mostraram que, de todos os corpos de prova modificados, os que receberam a Super Bonder® em sua superfície, G2(SBAE) e G3(SBDE) foram os únicos que significativamente reduziram a formação de biofilme de Candida albicans. Através da análise das imagens geradas pelo microscópio confocal, pôde-se observar que nos grupos G2(SBAE) e G3(SBDE) os campos apresentaram um reduzido número de células fúngicas e a maioria se encontrava na forma de levedura (inócua), enquanto que, para os demais grupos, além de observado um elevado número de células, a maioria destas se apresentava em forma de hifa (patogênica). Desse modo, a partir das condições experimentais desse estudo pôde-se concluir que as modificações do material testado com a Super Bonder® aplicada em sua superfície podem ser uma abordagem potencialmente útil para reduzir ou controlar a formação do biofilme em resinas acrílicas. / The purpose of this study was to verify, using the confocal laser scanning microscopy (CLSM), if the use of a photoactivated resin of low viscosity (Biscover®) and a ethyl-cyanoacrylate (Super Bonder®) could be efficient in the prevention or reduction of Candida albicans biofilms. Fifty six reline resin specimens (New Truliner) were fabricated and randomly divided into 7 groups: G1 (C)- Control; G2 (SBAE)- a Super Bonder® layer was applied on the surface before sterilization; G3 (SBDE)- the surface received a Super Bonder® layer after sterilization; G4 (SB3G)- 3 drops of Super Bonder® were incorporated in the structure of the resin; G5 (SB4G)- 4 drops of Super Bonder® were incorporated in the structure of the resin; G6 (BCDE)- a Biscover® layer was applied on the surface after sterilization; G7 (BCAE) the surface received a Biscover® layer before sterilization. All the specimens were inoculated with Candida albicans for biofilm dvelopment. The remaining biofilms on the specimens were stained with fluorochromes SYTO-9 and propidium iodide to be analyzed by CLSM. The data were statistically analyzed using the Kruskal-Wallis and Dunn test, considering a significance level of 5%. The data obtained by CLSM revealed that of all specimens modified, those that received a Super Bonder® layer on their surface, G2(SBAE) e G3(SBDE), presented the better results, reducing Candida albicans biofilm formation. Analyzing the images produced by CLSM it was possible to see that groups G2(SBAE) e G3(SBDE) showed a reduced number of cells, and they were in a less phatogenetic form (Yeast), while the other groups showed a high number of cells in a more pathogenetic form (Hyphae). Considering the experimental conditions of this study we can conclude that the material modifications done with Super Bonder® on the surface could be an interesting way to prevent or control biofilm formation on acrylic resin.
|
120 |
Avaliação clínica do efeito de dois métodos de desinfecção sobre a rugosidade, estabilidade de cor e formação de biofilme de próteses reembasadas /Moffa, Eduardo Buozi. January 2010 (has links)
Orientador: Eunice Teresinha Giampaolo / Banca: Ana Cláudia Pavarina / Banca: Janaina Habib Jorge / Resumo: Este estudo avaliou clinicamente o efeito de dois métodos para limpeza de próteses sobre a rugosidade, estabilidade de cor e a quantificação de micro-organismos de um reembasador rígido em diferentes intervalos de tempo. Foram selecionados 30 pacientes de ambos os gêneros com idade entre 40 e 80 anos, portadores de prótese total superior com necessidade de reembasamento. Essas próteses foram reembasadas com o material Tokuyama Rebase II Fast segundo as recomendações do fabricante. Em seguida, a amostra foi dividida em três grupos (n=10): GC (Grupo Controle) - os pacientes higienizaram suas próteses três vezes ao dia por meio de escovação com sabão de coco; GP (Grupo Perborato) - os pacientes realizaram escovação com sabão de coco e imersão diária da prótese em solução de perborato de sódio durante 5 minutos; GChx (Grupo Clorexidina) - nesse grupo, além da escovação com sabão de coco, foi realizada diariamente a imersão da prótese por 5 minutos em solução de digluconato de clorexidina 2%. Antes da colocação da prótese, os pacientes foram orientados a enxaguá-la adequadamente. A rugosidade superficial e estabilidade de cor do material reembasador foram avaliadas pelo profissional imediatamente após o reembasamento e após 7, 15, 30, 90, e 180 dias. A coleta de microoganismos foi realizada após 7, 15, 30, 90, e 180 dias. A rugosidade superficial foi mensurada através da utilização de um rugosímetro, que fornece valores em Ra-μm. A estabilidade de cor foi avaliada por meio de um espectrofotômetro portátil (BYK - Gardner). Os valores de ΔE obtidos foram comparados utilizando-se a classificação determinada pelo National Bureau of Standards (NBS). Análise de variância de medidas repetidas no tempo (p=0,05) foi empregada na avaliação dos métodos de desinfecção sobre a rugosidade superficial, estabilidade de cor e contagem... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of two disinfection methods for dentures on the clinical performance and quantification of microorganisms of a hard chairside reline resin in different time period. Thirty patients aged between 40 and 80 who required denture reline treatment, participated in this study. Tokuyama Rebase II was used to reline the complete dentures. After that, the edentulous subjects were ramdomly divided into three groups (n=10) and dentures were cleansed according to three methods: CG (control group) - brushing with coconut soap and soft toothbrush; PG (Perborate group) - brushing according to previous methods and disinfection with sodium perborate for 5 minutes once a day during the entire evaluation period (180 days) and ChxG (Chlorhexidine Group) - brushing according to CG and disinfection with chlorhexidine digluconate 2% for 5 minutes once a day during the entire evaluation period (180 days). Surface roughness and color stability were assessed immediately after the relining and after 7, 15, 30, 90 and 180 days of treatment. Quantitative microbial cultures were taken from the tissue side of each maxillary denture after 7, 15, 30, 90 and 180 days of dentures disinfection. The surface roughness was measured using a roughnes meter, which provides values in Ramicrometers. The color stability was evaluated by means of a portable espctrofotômetro (BYK - Gardner). The ΔE values were compared using the classification determined by the National Bureau of Standards (NBS). Analysis of variance for repeated measures (p = 0.05) were used in the evaluation of disinfection methods on the surface roughness, color stability and microbial counts (cfu / ml). The analysis of variance with repeated measures identified a significant effect only on the time factor (p <0.001) for the values of surface roughness, discoloration and microbial quantification... (Complete abstract click electronic access below) / Mestre
|
Page generated in 0.0492 seconds