• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 116
  • 49
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 168
  • 98
  • 76
  • 44
  • 35
  • 35
  • 33
  • 32
  • 30
  • 29
  • 29
  • 28
  • 27
  • 26
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Análise in vitro da estabilidade de próteses totais superiores implantossuportadas e implantorretidas / Analisys of the stability of maxillary overdentures An in vitro study

Aline Tany Posch 25 February 2014 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / Os sistemas de retenção utilizados em próteses totais sobre implante (sobredentaduras) tem sido discutidos ao longo das últimas décadas a fim de se obter uma padronização a respeito do tratamento clínico desses pacientes. Considerando o importante papel da estabilidade das próteses para a eficiência mastigatória, bem como para elaboração do plano de tratamento adequado, o objetivo deste estudo foi avaliar a estabilidade das próteses implantossuportadas e/ou implantorretidas, utilizando para isso um estudo in vitro que simulou a força de mordida. Materiais e Métodos: Foram testadas quatro tipo diferentes de próteses totais: 1) G1 Prótese Total Removível Convencional; 2) G2 - Próteses Total Removível sobre Implantes (Overdenture), retida pelo sistema ERA; 3) G3 Prótese Total Removível sobre Implantes (Overdenture), retida pelo sistema de Barra com clipes e Encaixes - ORCE; e 4) G4 - Prótese Total Fixa sobre Implantes, seguindo o protocolo Brånemark e utilizando o sistema de barras-distais da marca Neodent. Cada grupo foi submetido ao carregamento em pontos específicos, localizados sobre os elementos 16 (F=300N), 26 (F=300N) e na região anterior 11/21(F=100N). A aferição da estabilidade foi feita através da mensuração do deslocamento vertical da prótese durante o a aplicação da força e a distância do local do carregamento, sobre os elementos 16, 26 e na região anterior, nos elementos 11 e 21. Os dados passaram no teste de normalidade de Shapiro-Wilk e foram submetidos à análise de variância ANOVA e à comparação múltipla através do teste de Bonferroni (p<0.05) Resultados: O tipo de sistema utilizado influenciou na movimentação vertical da prótese na região posterior contralateral à aplicação de força, sendo a movimentação vertical G1 > G2 > G3 &#8805; G4. Na movimentação vertical da prótese nos dentes anteriores, quando a força foi aplicada nos dentes posteriores (rotação para posterior), a movimentação vertical foi de G1 > G2 > G3 &#8805; G4. Durante a rotação para posterior, quando a força foi aplicada nos dentes anteriores (rotação para anterior) e a movimentação medida nos dentes posteriores, o comportamento foi de G1 > G2 > G3 > G4. Conclusão: Em duas das três situações testadas não houve diferença estatística entre a movimentação vertical entre o G3 e o G4, sugerindo que a estabilidade da overdenture retida por barra com clipes e encaixes se comportou, em relação a estabilidade, semelhante a prótese fixa sobre implantes. / The retain systems used by the complete dentures have been discussed over the past decades in order to achieve a standardization regarding to the clinical treatment of the patients. Considering the important meaning of the stability of dentures for chewing efficiency and for planning appropriate treatment, the aim of this study was to evaluate the stability of the implant-supported and implant-retained prosthesis, using an in vitro study that simulated the bite force. Materials and Methods: Four different types of dentures were tested: 1) G1 - Conventional Denture; 2) G2 Overdenture retained by the ERA system ; 3) G3 - Overdenture retained by bar system using clipes and fittings; and 4) G4 - Total implant-supported Prosthesis, following the Brånemark protocol and using Neodent`s distal bar. Each group was subjected to loading at specific points, located on the elements 16, 26 (F = 300Ncm) and at the anterior region 11/21 (F = 100Ncm). The measurement of vertical displacement during the test was taken out-lying from the loading area and at the elements 16, 26 and in the anterior region, at the element 11/21. Results: The data was analyzed by Shapiro -Wilk normality Test and than by ANOVA and multiple comparisons using the Bonferroni test. Conclusions: The retention system have influenced the vertical movement of the prosthesis in the posterior region contralateral to force application point, with the vertical movement as G1 > G2 > G3 > G4. In the vertical movement of the prosthesis at anterior point, when the force was applied to the posterior teeth, the vertical movement was G1 > G2 > G3 > G4. When the load was applied to the anterior teeth and movement was measured ate the posterior teeth, the behavior was G1 > G2 > G3 > G4. In two of the three situations simulated, there was no statistical difference between the vertical movement between the G3 and G4, suggesting that the stability of overdentures retained by bar with clips and fittings performed like fixed prosthesis.
152

Análise da influência dos sistemas de retenção para overdentures implanto-retidas na distribuição interna das tensões, através do método de elementos finitos

Tabata, Lucas Fernando [UNESP] 05 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-05Bitstream added on 2014-06-13T20:37:56Z : No. of bitstreams: 1 tabata_lf_me_araca.pdf: 8309973 bytes, checksum: 5d726f976a2382ac0dc6e3d5eff78d89 (MD5) / Universidade Estadual Paulista (UNESP) / No tratamento com overdentures o mecanismo de transmissão e distribuição das tensões geradas por cargas funcionais através dos sistemas de retenção e implantes ao osso não está bem documentado. A intensidade e a forma como esta tensão é transmitida e distribuída ao osso determina os locais e a amplitude da reabsorção óssea. O objetivo deste estudo foi analisar, através do Método de Elementos Finitos (MEF) bidimensional, as tensões geradas pelas overdentures e transmitidas aos sistemas de retenção, implantes e tecido ósseo adjacente. Foram construídos em computador, através do programa AutoCAD, três modelos matemáticos representativos de cortes frontais da mandíbula na região inter-caninos, sendo: modelo A (Controle), mandíbula edêntula suporte de prótese total convencional; modelo B, mandíbula edêntula, suporte de overdenture com dois implantes ferulizados por meio de barra e clipe plástico; modelo C, mandíbula edêntula, suporte de overdenture com dois attachments esféricos O'rings em dois implantes isolados. Para análise, foi aplicada carga vertical de 100N em três regiões distintas: nos incisivos centrais inferiores, no canino inferior esquerdo e no primeiro molar inferior esquerdo. Os mapas de tensão evidenciaram as máximas e mínimas tensões e foram agrupados de acordo com as situações clínicas simuladas, para análise dos efeitos dos sistemas de retenção sobre as estruturas de suporte. O modelo A apresentou menores valores de tensão máxima (10,928MPa) que os modelos B (74,244MPa) e C (78,454MPa) em relação aos tecidos de suporte, sendo que os maiores valores foram obtidos no modelo C, na região peri-implantar do osso cortical para os três carregamentos aplicados. Os resultados sugerem a ferulização dos implantes e a utilização do sistema de retenção barra-clipe quando se pretende ter distribuição otimizada de tensões no tratamento com overdentures implanto-retidas. / on treatment with overdenture, the transfer and distribution mechanism of the stress generated by functional loads through retention system and implants to bone it is not well documented, The intensity and the manner how this stress is tranfered and distributed to bone determine the sites and amplitude of bone resorption. The objective of this study was to analyse, through Finite Element Analysis (FEA) bidimensional, the stress generated on overdentures and transfer to retention system, implants and surrounding bone tissue. Three mathematic models were made in computer, through AutoCAD software, representing a frontal mandibular slice of inter-canine... (Complete abstract click electronic access below)
153

Influência dos sistemas de retenção e da inclinação do rebordo residual em casos de próteses conjugadas Classe I mandibular: análise da distribuição das tensões pelo método da fotoelasticidade

Ferraço, Renato [UNESP] 24 April 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-04-24Bitstream added on 2014-06-13T19:37:37Z : No. of bitstreams: 1 ferraco_r_me_araca.pdf: 1898873 bytes, checksum: a4b549caf699d7868a711624716d6212 (MD5) / A reabilitação de pacientes classe I de Kennedy mandibular através de Prótese Parcial Removível é de difícil resolução devido a diferença de resiliência existente entre o ligamento periodontal dos dentes suportes e a mucosa do rebordo residual. A inclinação do rebordo residual no sentido sagital pode influenciar na distribuição das tensões transmitidas pela incidência de cargas em próteses parciais removíveis de extremidade livre associadas a próteses parciais fixas. Na associação da prótese parcial removível com próteses parciais fixas, o profissional tem como alternativa aos grampos tradicionais, o uso de encaixes extra-coronários que podem melhorar a estética e o funcionamento biomecânico do conjunto. Desse modo, o objetivo desse estudo foi avaliar a característica da distribuição de tensões em próteses parciais removíveis mandibulares de extremidade livre associadas a próteses parciais fixas nos dentes suporte com diferentes sistemas de retenção: (1) grampo por ação de pontas; (2) sistema ASC-52; (3) sistema ERA; e (4) encaixe de semi-precisão Score-PD, pela metodologia da fotoelasticidade. E, analisar a distribuição de tensões em próteses parciais removíveis mandibulares de extremidade livre associadas a próteses parciais fixas nos dentes suporte com diferentes sistemas de retenção: (1) grampo por ação de pontas e (2) sistema ERA, variando duas inclinações de rebordo residual: (1) horizontal e (2) descendente distal. Cargas axiais de 100N foram aplicadas sobre os dentes das próteses parciais removíveis. As imagens das aplicações foram capturadas e a distribuição das tensões foi avaliada, pela formação das franjas fotoelásticas. No primeiro estudo, a prótese com encaixes de semi-precisão produziu os maiores níveis de tensão na região de ápice, entre as raízes dos últimos dentes suporte e na porção mais distal do rebordo... / The rehabilitation of patients mandibular class I of Kennedy through Removable Partial Denture is difficult to solve because the difference in strength between the periodontal ligament of the abutment teeth and the residual ridge mucosa. The inclination of the residual ridge towards sagital may influence the distribution of stresses transmitted by the incidence of loads in distal extension removable partial dentures associated with fixed partial dentures. In association removable partial denture – fixed partial dentures, the professional has as alternative to the traditional clasps, the use of extra-coronary attachments that can improve the aesthetics and the biomechanics. Therefore, the objective of this study was to evaluate the characteristic distribution of tensions in mandibular distal extension removable partial dentures (1) “I” bar clasps, (2) ASC-52system, (3) ERA system, and (4) semi-precision Score-PD system, by the methodology of photoelasticity. And, analyze the distribution of tensions in mandibular distal extension removable partial dentures associated to the fixed partial dentures in the abutment teeth with different retention systems: (1) “I” bar clasps and (2) ERA system, ranging from two inclinations residual ridge: (1) horizontal and (2) distal descending. Axial loads of 100N were applied on the teeth of removable partial dentures. The images of the applications were captured and distribution of stress was assessed by the formation of the photoelastic fringes. In the first study, the prosthesis with semi-precision attachment produced the highest levels of tension in the region of apex, between the roots of the abutment teeth and in the more distal portion of the residual ridge. The prostheses with resilient attachments showed the largest fringes formations in the cervical-distal of the last abutment tooth. In the second study, horizontal ridge presented... (Complete abstract click electronic access below)
154

Análise fotoelástica da tensão entre diferentes tipos de sistemas de retenção em próteses obturadoras palatinas implanto-retidas ou não e com ou sem reembasamento “soft”

Ribeiro, Paula do Prado [UNESP] 13 April 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-04-13Bitstream added on 2014-06-13T20:18:39Z : No. of bitstreams: 1 ribeiro_pp_me_araca.pdf: 1296460 bytes, checksum: 0aa88d770aee2b3e8787125e444deac4 (MD5) / O câncer da região de cabeça e pescoço é uma doença muito prevalente no Brasil, e as principais formas de tratamento são a cirurgia acompanhada ou não da radioterapia e quimioterapia. Perdas parciais ou totais de osso maxilar podem comprometer seriamente a fisiologia bucal causando sequelas como comunicações buconasosinosal. Neste caso, podese optar como forma de tratamento pela reabilitação protética com a aplicação de implantes osseointegrados. A literatura odontológica tem mostrado inúmeros trabalhos que avaliam a distribuição de forças com a finalidade de recolher melhores subsídios para o planejamento de próteses bucomaxilofaciais, que ainda é pouquíssimo explorada. Dentre os métodos utilizados, o da fotoelasticidade tem sido aceito, especialmente por permitir uma análise fiel da distribuição de forças. Assim, a proposta deste trabalho foi verificar a tendência de distribuição de forças e estresse, através do método fotoelástico, que incidem sobre diferentes tipos de sistemas de retenção em implantes (o’ring, barra clipe e o’ring/barra clipe) associado a próteses obturadoras palatinas implantoretidas e também em próteses obturadoras mucossuportadas (sem implante), utilizandose ou não de silicone com reembasamento direto (Sofreliner). O conjunto (prótese e modelo fotoelástico) foi posicionado em polariscópio circular e recebeu aplicação de carga de 100 N a velocidade de 10 mm/s no primeiro molar de cada prótese. Após as aplicações de carga houve a formação franjas correspondentes à tensão registrada. Então, as imagens foram transferidas para um computador e analisadas no programa ADOBE Photoshop. Ao se comparar os três sistemas de retenção das próteses obturadoras palatinas implantoretidas com a prótese mucossuportada (sem implantes), podese observar que as tensões foram distribuídas de forma mais homogênea... / The head and neck cancer is a very prevalent disease in Brazil and the main treatment is the surgery with or without radiation therapy and chemotherapy. Partial or total bone maxillary defects could involve seriously oral physiology causing consequences as buconasosinosal communications. In this case could be applied other option of treatment as prosthetic rehabilitation associated with osseointegrated implants. Scientific literature demonstrated countless studies that evaluate the force distribution with the aim to provide better subsidies for the planning of bucomaxillofacial prostheses, which still have few researches. Between the methodologies, the photoelastic method has been accepted; especially by allow an accurate analysis of the force distribution. Thus, the aim of this study was to verify the tendency of force distribution and the stress on different types of retention system (o’ring, clip bar and o’ring/clip bar) associated with palatal obturator prostheses with implant retention and conventional obturator prostheses (without implants), with or without silicone soft lining(Sofreliner), by means of photoelastic method. The set (prosthesis and photoelastic model) was located in circular polariscope and was applied a load of 100 load N at 10 mm/s on the first molar of each prostheses. After the load applications was registered the tension fringes. The images was transferred to a computer and analyzed at ADOBE Photoshop software. When compared the three retention systems of the palatal obturator prostheses and mucosupported prostheses (without implants), it can be observed that the stress was distributed more homogeneous and in lesser amount that the conventional prostheses, when compared to the other prostheses that presented implants and retention systems. With relation to stress distribution in the different retention systems, the bar clip... (Complete abstract click electronic access below)
155

Avaliação in vitro da incorporação de clorexidina nas propriedades físico-químicas de resinas macias / In vitro incorporation of chlorhexidine on the physicochemical properties of soft resins

Camilla Alves Janott-Sarlo 30 January 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A incorporação do diacetato de clorexidina em resinas macias para reembasamento de próteses pode se tornar uma boa alternativa na terapia com antimicrobianos usados para candidíase oral, uma vez que é independente da cooperação do paciente. Este trabalho teve como objetivo analisar a hipótese que a incorporação de diacetato de clorexidina em resinas macias não alteraria as suas propriedades físico-químicas. Foram analisadas duas resinas macias, uma à base de polimetilmetacrilato (PMMA) e outra à base de polietilmetacrilato (PEMA), com a incorporação de 0,5%, 1,0% e 2,0% de diacetato de clorexidina, além do grupo controle sem diacetato de clorexidina. Os espécimes foram armazenadas em água destilada a 37 durante 2hrs, 48 hrs, 7, 14, 21 e 28 dias e analisados quanto a cristalinidade do polímero através da difração de Raios X, a dureza mensurada com durômetro na escala shore A, o grau de conversão dos monômeros pela Espectroscopia de Infravermelho Transformada de Fourier (FTIR), a lixiviação de monômeros residuais e a liberação da clorexidina por Cromatografia Líquida de Alta Performace (HPLC). Os resultados mostraram que quanto à cristalinidade dos polímeros nas resinas macias à base de PMMA e de PEMA não alteraram após a incorporação de clorexidina, o que está relacionado à dureza Shore A, que aumentou ao longo do tempo, mas sem alteração significativa para nenhuma das concentrações de diacetato de clorexidina testadas. Já quanto ao grau de conversão, após a incorporação de clorexidina, a resina macia à base de PMMA não apresentou diferença estatisticamente significativa (&#1088;>0,05), porém a resina macia à base de PEMA apresentou diminuição significativa do grau de conversão (p<0,05), o que refletiu no aumento significativo da lixiviação de monômeros residuais nas concentrações 0,5% e 1,0% de clorexidina (p<0,05), principalmente nas primeiras 48 horas nessa resina. A resina macia à base de PMMA não apresentou alterações do padrão de lixiviação desses monômeros (&#1088;>0,05) e para ambas as resinas a cinética de liberação de clorexidina foi relacionada à lixiviação de monômeros residuais, que para a resina macia à base de PEMA foi maior significativamente nas primeiras 48 horas (p<0,05) e para a resina macia à base de PMMA não teve alteração estatisticamente significativa (&#1088;>0,05) se mantendo até o último dia de análise. Desse modo, conclui-se que a incorporação do diacetato de clorexidina não afetou a cristalinidade dos polímeros, inalterando a dureza nas duas resinas, porém o grau de conversão sofreu diminuição após a incorporação de diacetato de clorexidina na resina macia à base de PEMA, o que levou ao aumento da lixiviação de monômeros residuais e curta liberação de clorexidina; enquanto que a resina macia à base de PMMA, devido a não alteração significativa do seu grau de conversão, ocorreu menor lixiviação de monômeros residuais e liberação prolongada de clorexidina. / Chlorhexidine incorporation in soft denture liners can become a good antimicrobial treatment alternative for oral candidiasis, since it is independent of patient compliance. Considering this, the present study evaluate the hypothesis that chlorhexidine diacetate (CDA) incorporation in soft denture liners would not change their physical-chemical properties. For this, two soft resins were tested, one based on poly methylmethacrylate (PMMA) and the other based on poly ethylmethacrylate (PEMA), which received 0.5%, 1.0% and 2.0% of CDA incorporation, in addition to a control group without CDA. Specimens were stored in distilled water at 37 C during 2 hrs, 48 hrs, 7, 14, 21 and 28 days, then analyzed for polymer crystallinity through X-Ray diffraction, Shore A hardness measured with a durometer, degree of monomers conversion by Fourier transform infrared spectroscopy (FTIR), the leaching of residual monomers and release of CDA by high performance liquid chromatography (HPLC). Results showed that polymer crystallinity of PEMA and PMMA were not changed after CDA incorporation, this results is related to Shore A hardness, which increased over time, but not for any CDA concentrations tested. Considering the degree of monomers conversion, PMMA based resin did not present significant statistic difference (&#1088;>0.05), however the PEMA based resin had a significantly decrease on its degree of conversion (p<0.05), which was reflected in a significant increase of residual monomers leaching from PEMA based resin with 0.5% and 1.0% CDA incorporation (p<0.05), mainly in the firsts 48 hours. PMMA based resin had no alteration on its monomers leaching (&#1088;>0.05) and for both resins their CDA release kinetics was related to the monomers leaching, which for PEMA based resin was significantly greater in the first 48 hours (p<0.05) and for PMMA based resin was more sustained up to the last day of analysis. Thus, it is concluded that CDA incorporation do not affect polymers crystallinity and do not change their hardness, but the monomers conversion degree decrease for PEMA based resin, leading to an increase of residual monomers leaching and shorter CDA release, while for PMMA based resin, because of no change on their monomers conversion degree, there was less residual monomers leaching and prolonged CDA release.
156

Análise in vitro da estabilidade de próteses totais superiores implantossuportadas e implantorretidas / Analisys of the stability of maxillary overdentures An in vitro study

Aline Tany Posch 25 February 2014 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / Os sistemas de retenção utilizados em próteses totais sobre implante (sobredentaduras) tem sido discutidos ao longo das últimas décadas a fim de se obter uma padronização a respeito do tratamento clínico desses pacientes. Considerando o importante papel da estabilidade das próteses para a eficiência mastigatória, bem como para elaboração do plano de tratamento adequado, o objetivo deste estudo foi avaliar a estabilidade das próteses implantossuportadas e/ou implantorretidas, utilizando para isso um estudo in vitro que simulou a força de mordida. Materiais e Métodos: Foram testadas quatro tipo diferentes de próteses totais: 1) G1 Prótese Total Removível Convencional; 2) G2 - Próteses Total Removível sobre Implantes (Overdenture), retida pelo sistema ERA; 3) G3 Prótese Total Removível sobre Implantes (Overdenture), retida pelo sistema de Barra com clipes e Encaixes - ORCE; e 4) G4 - Prótese Total Fixa sobre Implantes, seguindo o protocolo Brånemark e utilizando o sistema de barras-distais da marca Neodent. Cada grupo foi submetido ao carregamento em pontos específicos, localizados sobre os elementos 16 (F=300N), 26 (F=300N) e na região anterior 11/21(F=100N). A aferição da estabilidade foi feita através da mensuração do deslocamento vertical da prótese durante o a aplicação da força e a distância do local do carregamento, sobre os elementos 16, 26 e na região anterior, nos elementos 11 e 21. Os dados passaram no teste de normalidade de Shapiro-Wilk e foram submetidos à análise de variância ANOVA e à comparação múltipla através do teste de Bonferroni (p<0.05) Resultados: O tipo de sistema utilizado influenciou na movimentação vertical da prótese na região posterior contralateral à aplicação de força, sendo a movimentação vertical G1 > G2 > G3 &#8805; G4. Na movimentação vertical da prótese nos dentes anteriores, quando a força foi aplicada nos dentes posteriores (rotação para posterior), a movimentação vertical foi de G1 > G2 > G3 &#8805; G4. Durante a rotação para posterior, quando a força foi aplicada nos dentes anteriores (rotação para anterior) e a movimentação medida nos dentes posteriores, o comportamento foi de G1 > G2 > G3 > G4. Conclusão: Em duas das três situações testadas não houve diferença estatística entre a movimentação vertical entre o G3 e o G4, sugerindo que a estabilidade da overdenture retida por barra com clipes e encaixes se comportou, em relação a estabilidade, semelhante a prótese fixa sobre implantes. / The retain systems used by the complete dentures have been discussed over the past decades in order to achieve a standardization regarding to the clinical treatment of the patients. Considering the important meaning of the stability of dentures for chewing efficiency and for planning appropriate treatment, the aim of this study was to evaluate the stability of the implant-supported and implant-retained prosthesis, using an in vitro study that simulated the bite force. Materials and Methods: Four different types of dentures were tested: 1) G1 - Conventional Denture; 2) G2 Overdenture retained by the ERA system ; 3) G3 - Overdenture retained by bar system using clipes and fittings; and 4) G4 - Total implant-supported Prosthesis, following the Brånemark protocol and using Neodent`s distal bar. Each group was subjected to loading at specific points, located on the elements 16, 26 (F = 300Ncm) and at the anterior region 11/21 (F = 100Ncm). The measurement of vertical displacement during the test was taken out-lying from the loading area and at the elements 16, 26 and in the anterior region, at the element 11/21. Results: The data was analyzed by Shapiro -Wilk normality Test and than by ANOVA and multiple comparisons using the Bonferroni test. Conclusions: The retention system have influenced the vertical movement of the prosthesis in the posterior region contralateral to force application point, with the vertical movement as G1 > G2 > G3 > G4. In the vertical movement of the prosthesis at anterior point, when the force was applied to the posterior teeth, the vertical movement was G1 > G2 > G3 > G4. When the load was applied to the anterior teeth and movement was measured ate the posterior teeth, the behavior was G1 > G2 > G3 > G4. In two of the three situations simulated, there was no statistical difference between the vertical movement between the G3 and G4, suggesting that the stability of overdentures retained by bar with clips and fittings performed like fixed prosthesis.
157

Avalia??o da desadapta??o das selas de pr?teses parciais remov?veis ap?s 1 a 5 anos de uso

Aquino, Luana Maria Martins de 03 February 2009 (has links)
Made available in DSpace on 2014-12-17T15:30:52Z (GMT). No. of bitstreams: 1 LuanaMMA.pdf: 2018250 bytes, checksum: 40d3a2d59df5edbadcdae3ffaf599eb2 (MD5) Previous issue date: 2009-02-03 / The non-adaptation of the removable partial prosthesis (RPP) base to fibromucosal tissue is caused by resorption of residual ridges (RRR). The onset of bone resorption, which occurs after tooth extraction and continues throughout life, is accelerated by local or systemic factors. Aim: Assess the degree of non-adaptation of removable partial prosthesis saddles and the factors that influence it. Methodology: A sectional study was conducted with 81 patients using RPP who had their prostheses installed between 2003 and 2007 (1 to 5 years of use) at the Faculty of Dentistry of the Universidade Federal do Rio Grande do Norte (UFRN). After anamnese and clinical examination, a cast was made with polyether-based material, using the base of the prosthesis to make the impression. The base of the saddle was loaded with the casting material and positioned in the mouth, applying pressure on the supports. After polymerization, the material was removed from the saddle and measurements were taken at 3 different points using a pachymeter. Results: The non-adaptation of the saddle increased significantly with years of use (p = 0.005). The tooth-tissue supported prostheses obtained higher mean non-adaptation values than those of tooth supported prostheses (p < 0.001). Flaccid mucosa showed the worst non-adaptation results, which were statistically different from resilient mucosa (p < 0.001). The greater the extension of the saddle, the greater the non-adaptation (p < 0.001). The natural tooth antagonistic arch yielded better results than did RPP and total prosthesis (p < 0.001). Saddle non-adaptation at the free end was less near the pillar tooth and greater in the more posterior region (p < 0.001). When adaptation of the supports to the niches was poor, greater saddle non-adaptation occurred than when it was good or fair (p < 0.001). Saddles located in the posterior region of the arch had greater non-adaptation than those in the anterior region (p = 0.023). Conclusion: The mean non-adaptation of the saddle to the residual ridges was 0.27 mm. It can be concluded that, even with the use of RPP, bone height reduction was slight within the 1-5-year period of use. The following are factors that influence adaptation of the RPP saddle base: years of use, age, force transmission path to the alveolar bone, location of the toothless area, antagonistic arch, type of mucosa, adaptation of supports to the niche and extension of the saddle / A desadapta??o da base das pr?teses parciais remov?veis (PPR) com o tecido fibromucoso ? causada pela reabsor??o dos rebordos residuais (RRR). A reabsor??o ?ssea inicia logo ap?s a exodontia de um elemento dent?rio e continua por toda a vida, sendo acelerada por fatores locais ou sist?micos. Objetivo: Avaliar o grau de desadapta??o das selas de pr?teses parciais remov?veis e os fatores que a influenciam. Metodologia: Foi realizado um estudo seccional com 81 pacientes usu?rios de PPR que instalaram suas pr?teses no per?odo de 2003 a 2007 (1 a 5 anos de uso) no Departamento de Odontologia da UFRN. Ap?s a anamnese e do exame f?sico, foi realizada uma moldagem com material a base de poli?ter, utilizando a base da pr?tese como moldeira, para copiar o espa?o existente entre a base da sela e o rebordo residual. A base da sela foi carregada com o material de moldagem e levada em posi??o na boca, fazendo-se press?o sobre os apoios. Ap?s a polimeriza??o, removeu-se o material de moldagem da sela e realizou-se a medi??o da espessura do molde com o aux?lio de um paqu?metro manual. Resultados: A desadapta??o da sela aumentou significativamente a medida que aumentavam os anos de uso (p=0,005). Indiv?duos com 50 anos ou mais, apresentaram maior desadapta??o do que indiv?duos mais jovens (p<0,001). As pr?teses dentomucossuportadas obtiveram maiores m?dias de desadapta??o do que as dentossuportadas (p<0,001). O tipo de mucosa fl?cida apresentou piores resultados de adapta??o sendo estatisticamente diferente da mucosa resiliente (p<0,001). Quanto maior a extens?o da sela, maior a desadapta??o (p<0,001). O arco antagonista dente natural apresentou melhores resultados em rela??o a PPR e pr?tese total (p<0,001). A desadapta??o da sela em extremidade livre foi menor pr?ximo ao dente pilar e maior na regi?o mais posterior da sela (p<0,001). A adapta??o dos apoios aos nichos quando se encontrava ruim obteve maior desadapta??o da sela comparadas as adapta??es do tipo boa e regular (p<0,001). Selas localizadas em regi?o posterior do arco obtiveram maiores desadapta??o que as selas em regi?o anterior (p=0,023). Conclus?o: A m?dia de desadapta??o da sela sobre os rebordos residuais foi de 0,27mm, podendo-se concluir que, mesmo com o uso da PPR, a redu??o da altura ?ssea foi pequena dentro do per?odo de 1 a 5 anos de uso. S?o fatores que influenciam na adapta??o da base da sela de PPR: tempo de uso da pr?tese, idade, via de transmiss?o de for?a para o osso alveolar, local da ?rea desdentada, arco antagonista, tipo de mucosa, adapta??o dos apoios nos nichos e extens?o da sela
158

Avaliação in vitro da incorporação de clorexidina nas propriedades físico-químicas de resinas macias / In vitro incorporation of chlorhexidine on the physicochemical properties of soft resins

Camilla Alves Janott-Sarlo 30 January 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A incorporação do diacetato de clorexidina em resinas macias para reembasamento de próteses pode se tornar uma boa alternativa na terapia com antimicrobianos usados para candidíase oral, uma vez que é independente da cooperação do paciente. Este trabalho teve como objetivo analisar a hipótese que a incorporação de diacetato de clorexidina em resinas macias não alteraria as suas propriedades físico-químicas. Foram analisadas duas resinas macias, uma à base de polimetilmetacrilato (PMMA) e outra à base de polietilmetacrilato (PEMA), com a incorporação de 0,5%, 1,0% e 2,0% de diacetato de clorexidina, além do grupo controle sem diacetato de clorexidina. Os espécimes foram armazenadas em água destilada a 37 durante 2hrs, 48 hrs, 7, 14, 21 e 28 dias e analisados quanto a cristalinidade do polímero através da difração de Raios X, a dureza mensurada com durômetro na escala shore A, o grau de conversão dos monômeros pela Espectroscopia de Infravermelho Transformada de Fourier (FTIR), a lixiviação de monômeros residuais e a liberação da clorexidina por Cromatografia Líquida de Alta Performace (HPLC). Os resultados mostraram que quanto à cristalinidade dos polímeros nas resinas macias à base de PMMA e de PEMA não alteraram após a incorporação de clorexidina, o que está relacionado à dureza Shore A, que aumentou ao longo do tempo, mas sem alteração significativa para nenhuma das concentrações de diacetato de clorexidina testadas. Já quanto ao grau de conversão, após a incorporação de clorexidina, a resina macia à base de PMMA não apresentou diferença estatisticamente significativa (&#1088;>0,05), porém a resina macia à base de PEMA apresentou diminuição significativa do grau de conversão (p<0,05), o que refletiu no aumento significativo da lixiviação de monômeros residuais nas concentrações 0,5% e 1,0% de clorexidina (p<0,05), principalmente nas primeiras 48 horas nessa resina. A resina macia à base de PMMA não apresentou alterações do padrão de lixiviação desses monômeros (&#1088;>0,05) e para ambas as resinas a cinética de liberação de clorexidina foi relacionada à lixiviação de monômeros residuais, que para a resina macia à base de PEMA foi maior significativamente nas primeiras 48 horas (p<0,05) e para a resina macia à base de PMMA não teve alteração estatisticamente significativa (&#1088;>0,05) se mantendo até o último dia de análise. Desse modo, conclui-se que a incorporação do diacetato de clorexidina não afetou a cristalinidade dos polímeros, inalterando a dureza nas duas resinas, porém o grau de conversão sofreu diminuição após a incorporação de diacetato de clorexidina na resina macia à base de PEMA, o que levou ao aumento da lixiviação de monômeros residuais e curta liberação de clorexidina; enquanto que a resina macia à base de PMMA, devido a não alteração significativa do seu grau de conversão, ocorreu menor lixiviação de monômeros residuais e liberação prolongada de clorexidina. / Chlorhexidine incorporation in soft denture liners can become a good antimicrobial treatment alternative for oral candidiasis, since it is independent of patient compliance. Considering this, the present study evaluate the hypothesis that chlorhexidine diacetate (CDA) incorporation in soft denture liners would not change their physical-chemical properties. For this, two soft resins were tested, one based on poly methylmethacrylate (PMMA) and the other based on poly ethylmethacrylate (PEMA), which received 0.5%, 1.0% and 2.0% of CDA incorporation, in addition to a control group without CDA. Specimens were stored in distilled water at 37 C during 2 hrs, 48 hrs, 7, 14, 21 and 28 days, then analyzed for polymer crystallinity through X-Ray diffraction, Shore A hardness measured with a durometer, degree of monomers conversion by Fourier transform infrared spectroscopy (FTIR), the leaching of residual monomers and release of CDA by high performance liquid chromatography (HPLC). Results showed that polymer crystallinity of PEMA and PMMA were not changed after CDA incorporation, this results is related to Shore A hardness, which increased over time, but not for any CDA concentrations tested. Considering the degree of monomers conversion, PMMA based resin did not present significant statistic difference (&#1088;>0.05), however the PEMA based resin had a significantly decrease on its degree of conversion (p<0.05), which was reflected in a significant increase of residual monomers leaching from PEMA based resin with 0.5% and 1.0% CDA incorporation (p<0.05), mainly in the firsts 48 hours. PMMA based resin had no alteration on its monomers leaching (&#1088;>0.05) and for both resins their CDA release kinetics was related to the monomers leaching, which for PEMA based resin was significantly greater in the first 48 hours (p<0.05) and for PMMA based resin was more sustained up to the last day of analysis. Thus, it is concluded that CDA incorporation do not affect polymers crystallinity and do not change their hardness, but the monomers conversion degree decrease for PEMA based resin, leading to an increase of residual monomers leaching and shorter CDA release, while for PMMA based resin, because of no change on their monomers conversion degree, there was less residual monomers leaching and prolonged CDA release.
159

Retenção de grampos cirucenferenciais associados a retentores intra-radiculares com encaixe era utilizados em overdentures parciais removíveis / Retention clips cirucenferenciais associated with CuAlZn with docking was used in removable partial overdentures

SOUZA, José Everaldo de Aquino 18 July 2008 (has links)
Made available in DSpace on 2014-07-29T15:21:59Z (GMT). No. of bitstreams: 1 dissertacao everaldo.pdf: 1049399 bytes, checksum: fe0d5a65718b57ccb2f6a6d2bf11cb9a (MD5) Previous issue date: 2008-07-18 / The overdentures can be defined as total or partial removable dentures that cover root or osseo integrated implants rehabilitating the whole dentition. The mechanical retention in the removable partial overdentures (RPOs) is obtained through the use of cast clasps and attachments. This biomechanical principle has a great importance, since is inwardly associated with long term behavior and clinical performance of prosthesis and consequently, with comfort and satisfaction of the patients. So, the aim of this study was to assess the retention of metallic framework with simple circumferential claps associated intraradicular retainer with attachment type ERA (Extra coronal Resilient Attachment, Sterngold Implamed, Attleboro, EUA) in function of the metals based cobalt-chromium alloy (Co-Cr), titanium commercially pure (Ti cp) and nickel-chromium with titanium alloy (Ni-Cr with Ti), of the retentive undercuts of 0,25mm and 0,75mm and in function of the time of use in each simulated period (initial, 6 months, 1, 2, 3, 4 e 5 years). Through of metallic matrices representing a partially edentulous mandibular right hemi-arch segment constituted by the crown of the first molar, root of the inferior canine and with the absent of the premolars, were made 60 metallic frameworks being obtained 03 groups of each metal and subgroups representative of the 0,25mm and 0,75mm retentive undercuts of the circumferential clasp (totalizing 10 samples in each subgroup). Acrylic denture bases were constructed on the denture space and on the canine root that anchored the attachments and these received retentive capsules in the gray color of the system. Previously the mechanic tests, radiographic exams of the Ti cp frameworks were realized with the aim of detecting possible casting defects that could avert the posterior use. Next, the samples were mechanically tested simulating the insertion and removal of the framework using the testing apparatus designed at the Ribeirão Preto School of Dentistry (Testing apparatus, São Paulo University, Ribeirão Preto, Brazil), representing 5 years of simulated used. To simulate the intraoral conditions and realize the tests, a gadget fulfilled with artificial saliva was adapted in the testing apparatus. The retentive force data were recorded and submitted linear regression analysis and analysis of variance (ANOVA) to gauge a presence or not of significant differences and applied the Tukey complementary test 5% to comparison of the differences between the groups and subgroups. The groups of Ni-Cr with Ti and Co-Cr samples obtained most retentive mean with significant differences to group of Ti cp samples that obtained least retentive mean in every periods of time analyzed. To groups Ni-Cr with Ti and Co-Cr samples there was not significant difference of retention between the times analyzed free-standing of retentive undercuts (p > 0,05). In the group Ti cp samples there was significant difference of retention between the times analyzed just to subgroup samples with 0,75mm undercuts (p < 0,05). The Ni-Cr with Ti and Co-Cr samples with 0,75mm undercuts presented the most retentive mean and the Co-Cr samples with 0,25mm undercuts presented retention mean intermediate between biomechanical design in every periods of time analyzed. The Ti cp samples with 0,25mm undercuts presented the least retentive mean until second year of the analyze and the Ti cp samples with 0,75mm undercuts presented the least retentive mean of third until fifth year of the analyse. The circumferential claps casting in Ti cp used in 0,75mm undercuts have potential risk of fractures, mainly after the 2o year of use / As overdentures (sobredentaduras) podem ser definidas como próteses removíveis totais ou parciais, que cobrem raízes ou implantes osseointegrados reabilitando toda a dentição. A retenção mecânica nas overdentures parciais removíveis (OPRs) é obtida por meio da utilização combinada de grampos fundidos e encaixes. Este princípio biomecânico é de grande importância, visto que está intimamente relacionado com o comportamento e o desempenho clínico em longo prazo das próteses e conseqüentemente, com o conforto e satisfação dos pacientes. Assim, o objetivo deste estudo foi avaliar a retenção de estruturas com grampos circunferenciais simples associadas a retentores intra-radiculares com encaixe do tipo ERA (Extra coronal Resilient Attachment, Sterngold Implamed, Attleboro, EUA) em função dos metais à base de cobalto-cromo (Co-Cr), titânio comercialmente puro (Ti cp) e níquel-cromo com titânio (Ni-Cr com Ti), dos contornos retentivos de 0,25mm e 0,75mm e em função do tempo de uso em cada período simulatório (inicial, 6 meses, 1, 2, 3, 4 e 5 anos). A partir de matrizes metálicas representativas de uma hemi-arcada inferior direita parcialmente desdentada com as presenças da coroa do primeiro molar, raiz do canino e com os pré-molares ausentes, foram confeccionadas 60 estruturas metálicas sendo obtidos 3 grupos de cada metal e subgrupos representativos dos contornos retentivos de 0,25mm e 0,75mm do grampo circunferencial (perfazendo 10 amostras por subgrupo). Foram confeccionadas bases protéticas sobre o espaço protético e raiz do canino que ancoraram os encaixes e estes receberam as cápsulas retentivas de cor cinza do sistema. Previamente aos ensaios mecânicos, exames radiográficos das estruturas em Ti cp foram realizados para detectar possíveis defeitos de fundição que pudessem inviabilizar o uso posterior. Em seguida, as amostras foram ensaiadas mecanicamente simulando movimentos de inserção e remoção da estrutura utilizando uma máquina de ensaios projetada na Faculdade de Odontologia de Ribeirão Preto (Máquina de Ensaios, Universidade de São Paulo, Ribeirão Preto, Brasil), representando o uso simulado de 5 anos. Para simular as condições intrabucais e realizar os ensaios, um dispositivo preenchido com saliva artificial foi adaptado ao simulador. Os dados de força retentiva foram registrados e submetidos à análise de regressão linear e à análise de variância (ANOVA) para aferir a presença ou não de diferenças estatisticamente significativas e aplicado o teste de Tukey à 5% de probabilidade para comparação das diferenças entre os grupos e subgrupos. As amostras dos grupos em Ni-Cr com Ti e Co-Cr obtiveram as maiores médias de retenção com diferenças estatisticamente significantes para as amostras do grupo em Ti cp que obtiveram as menores médias de retenção em todos os períodos de tempo analisados. Para os grupos das amostras em Ni-Cr com Ti e Co-Cr não houve diferença de retenção estatisticamente significante entre os tempos analisados independente dos contornos retentivos (p > 0,05). No grupo das amostras em Ti cp houve diferença de retenção estatisticamente significante entre os tempos analisados apenas para as amostras do subgrupo com contorno retentivo de 0,75mm (p < 0,05). As amostras em Ni-Cr com Ti e em Co-Cr com contorno retentivo de 0,75mm apresentaram as maiores médias de retenção e as amostras em Co-Cr com contorno retentivo de 0,25mm apresentaram retenções médias intermediárias entre os desenhos biomecânicos em todos os períodos de tempo analisados. As amostras em Ti cp com contorno retentivo de 0,25mm apresentaram as menores médias de retenção até o segundo ano de análise e as amostras em Ti cp com contorno retentivo de 0,75mm apresentaram as menores médias de retenção do terceiro ao quinto ano de análise. Os grampos circunferenciais fundidos em Ti cp utilizados em contornos retentivos de 0,75mm tem um risco potencial de fraturas, principalmente após o 2o ano de uso
160

Avaliação in vitro das variações posicionais da cabeça da mandíbula na fossa articular decorrentes da alteração dimensional de resinas acrílicas para base de prótese total submetidas a diferentes técnicas de processamento / In vitro evaluation of changes in the position of the mandibular condyle in consequence of dimensional changes in denture base acrylic resins submitted to different processing methods

Tatiana de Carvalho Guarnieri 11 September 2006 (has links)
Este estudo teve o objetivo de avaliar in vitro a influência da alteração dimensional de resinas acrílicas para base de prótese total submetidas a diferentes formas de processamento sobre a posição da cabeça da mandíbula, buscando estabelecer uma possível relação com a etiologia das disfunções crânio-mandibulares nos pacientes usuários desse tipo de prótese. Foram duas etapas: a primeira parte enfocou o papel do tipo de prensa (Getom ou de cozimento) e da força de prensagem para fechamento da mufla (1000 ou 1500 kgf) utilizados no processamento de duas resinas: Lucitone 550 e QC–20 e somente da força de prensagem para a resina Acron MC. Já a segunda parte do estudo teve o intuito de avaliar a influência dos ciclos de polimerização curtos e longos na alteração dimensional de cinco resinas: as mesmas três da primeira parte, além da Clássico e Ondacryl. As próteses superiores acrilizadas foram remontadas em articulador totalmente ajustável, tendo como referência a posição de máxima intercuspidação (MIC). Nessa posição de maior estabilidade oclusal, foi vazado gesso tipo IV no espaço entre as esferas condilares do articulador e as paredes dos estojos condilares. Após a cristalização, esses corpos-de-prova de gesso foram removidos do estojo condilar e suas dimensões medidas e submetidas à análise estatística por meio de um modelo de análise de variância com medidas repetidas que permitiu concluir que houve variações na posição da “cabeça da mandíbula” em 625 das 630 medidas efetuadas; as médias de movimentação condilar variaram de 0,118 (DP = 0,0968) a 1,956 mm (DP = 0,414) e ocorreram principalmente no sentido posterior do lado esquerdo; na maioria dos casos em que a força de prensagem agiu como fator devariação, os deslocamentos obtidos com 1500 kgf foram menores do que aqueles obtidos com 1000 kgf; nos casos em que o tipo de prensa agiu como fator de variação, ora os menores deslocamentos foram obtidos com a prensa de cozimento, ora com a Getom; o ciclo empregado na polimerização não influenciou significativamente na estabilidade dimensional das próteses totais e a única diferença encontrada envolveu a resina Clássico, que levou aos maiores deslocamentos no sentido posterior do lado esquerdo. / The purpose of this study was to evaluate in vitro the influence of dimensional changes in denture base acrylic resins submitted to different processing methods on the position of the mandibular condyle. This was done to establish a relation between these dimensional changes and the etiology of temporomandibular disorders in complete denture wearers. This research was divided into two parts. The first part focused on the type of press (conventional water bath or Getom), on the pressing force for flask closure (1000 or 1500 kgf) when processing Lucitone 550 and QC-20 resins, and on the pressing force when processing Acron MC resin. The purpose of the second part was to evaluate the influence of polymerization time on the dimensional stability of five resins, namely Lucitone 550, QC-20, Acron MC, Clássico and Ondacryl. The polymerized upper prostheses were remounted on a fully adjustable articulator, using the maximal intercuspal position (MIP) as reference. Type IV dental stone was poured into the space between the condylar spheres and the condylar walls. After the dental stone dried, the samples were removed from the articulator and their dimensions were measured and submitted to analysis of variance with repeated measures. The following conclusions were drawn: 625 from 630 measurements done showed changes in the position of the “mandibular condyle” and mean values for condylar movement ranged from 0.118 (SD = 0.0968) to 1.956 mm (SD = 0.414) and occurred mainly in the posterior direction on the left side; in most cases where the pressing force influenced the condylar position, the changes were smaller in 1500 kgf group than in the 1000 kgf group; in the cases where the type of press influenced the changes in condylar position, the smallest values were found in both groups, sometimes with Getom and other times with conventional water bath press; polymerization time did not significantly affect the dimensional stability of the dentures and the greatest changes occurred in the posterior direction on the left side with Clássico resin.

Page generated in 0.0683 seconds