• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 138
  • 31
  • 4
  • 2
  • 1
  • Tagged with
  • 176
  • 62
  • 42
  • 42
  • 34
  • 30
  • 28
  • 27
  • 26
  • 23
  • 20
  • 19
  • 17
  • 16
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Investigação de negligência espacial unilateral após Acidente Vascular Cerebral

Luvizutto, Gustavo José. January 2016 (has links)
Orientador: Luiz Antônio de Lima Resende / Resumo: Introdução: A negligência espacial unilateral (NEU) é caracterizada pela incapacidade de reportar ou responder pessoas ou objetos do lado contralateral à lesão cerebral, e ocorre principalmente após Acidente Vascular Cerebral (AVC) do lobo parietal direito, sendo associada à pior desfecho funcional à longo prazo. Objetivo: Os objetivos desta tese foram: normatizar os principais testes diagnósticos de NEU e verificar a relação com fatores sócio-demográficos na população brasileira; avaliar as variáveis bioquímicas que interferem na NEU na fase aguda do AVC; e revisar sistematicamente os principais tratamentos farmacológicos na NEU em pacientes após AVC. Método: Para o primeiro objetivo foi realizado estudo transversal em 150 indivíduos sem alterações neurológicas, sendo aplicados: teste face-mão (TFM), testes de cancelamento de linhas (TCL), cancelamento de estrelas (TCE) e bisseção de linhas (TBL). Os resultados dos testes foram relacionados com o perfil sócio demográfico da população, sendo estipulado pontos de cortes para a normalidade; para o objetivo 2 foi realizado estudo observacional em 40 indivíduos com diagnostico de NEU após AVC. Foram aplicados os TCL, TCE e TBL, sendo relacionado com o nível de hemoglobina na fase aguda do AVC corrigido para potenciais confundidores; para o objetivo 3 foi realizado revisão sistemática de literatura por meio de ensaios clínicos randomizados e quasi-randomizados para determinar o melhor tratamento farmacológico. Resultados: os resul... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
142

"Emissão Eletrociclotrônica no Tokamak TCABR: Um Estudo Experimental" / Electron Cyclotron Emission in the TCABR Tokamak: An Experimental Study.

António Manuel Marques Fonseca 15 August 2005 (has links)
Descreve-se neste trabalho um estudo experimental da Emissão Eletrociclotrônica (EEC) no tokamak TCABR. Um radiômetro de EEC foi instalado, calibrado e utilizado para o estudo do plasma em descargas térmicas. O radiômetro é do tipo heteródino de varredura operando na faixa de 50-85 GHz, no modo extraordinário e na segunda harmônica. Determinou-se a temperatura de ruído do radiômetro e também sua estabilidade em amplitude e freqüência. Foi medida a largura de banda em freqüência do radiômetro (resolução espacial horizontal). A antena utilizada é do tipo gaussiana sendo que o raio da cintura do feixe gaussiano e a posição do foco foram experimentalmente determinados (W0 ~ 1 cm e d ~ 37 cm, respectivamente). A posição da cintura da antena foi posicionada próxima do centro geométrico do vaso. Foi feita a calibração absoluta do equipamento considerando-se os efeitos das janelas de diagnóstico (reflexão e absorção). O sistema pode operar em modo varredura, para a obtenção de perfis radiais de Te ou modo freqüência única onde se tem alta resolução temporal. As medidas da radiação EC foram feitas, na sua maioria, em descargas com densidade eletrônica média entre 1.10+19 m-3 e 1,5.1019 m-3 de forma a se ter acessibilidade da radiação EC e também minimizar-se a presença de elétrons fugitivos. Para ne > 1,5.1019 m-3 (com B0 = 1,14 T) verifica-se o corte parcial da radiação EC. Nesta condição, o corte na EEC foi utilizado na determinação do perfil radial da densidade eletrônica e aplicado em três diferentes situações: descargas com injeção adicional de gás, com a aplicação do eletrodo de polarização e em descargas com injeção de ondas de radiofreqüência na região das ondas de Alfvén para o TCABR. Usando um perfil parabólico típico para a densidade eletrônica, observou-se que, para descargas com injeção adicional de gás ou em descargas com a aplicação de ondas de radiofreqüência tem-se 0,85 < alfa < 1, e para descargas com aplicação do eletrodo de polarização obteve-se alfa ~ 0,6. Foram feitas observações simultâneas da temperatura eletrônica, a partir do sinal da EEC, e das oscilações de Mirnov (freqüência ~ 11,7 kHz) em descargas térmicas com q(r=0) > 1. Os resultados indicam a presença de um modo de ruptura dominante em rs ~ 9,5 cm com a largura da ilha magnética de W ~ 2,0-2,5 cm. Estes resultados experimentais obtidos estão em acordo com os resultados indicados por teorias de transporte na região das ilhas magnéticas. Observou-se também que a localização da ilha magnética coincide com uma região onde o perfil radial da temperatura de plasma é aproximadamente plano. Num outro cenário, com q(r=0) < 1, observaram-se oscilações dente de serra com período de ~ 0,44 ms, tempo de queda de ~ 0,12 ms, e raio de inversão em r ~ 4 cm. Neste tipo de descargas observou-se que, no perfil radial da amplitude das oscilações da Te, |DeltaTe|, devido à propagação dos pulsos dente de serra, apresentavam posições de mínimos e que estes coincidiam com as posições onde ocorrem patamares no perfil radial da temperatura eletrônica. Partindo destes resultados, juntamente com o perfil de q(r), dão-nos os modos racionais (m/n), posições (r) e larguras(W) para as ilhas magnéticas, presentes nestas descargas, a saber: m/n = 4/3 (r ~ 9 cm, W4/3 ~ 0,9 cm), m/n = 3/2 (r ~ 11,8 cm, W3/2 ~ 0,9 cm) e m/n = 2/1 (r ~ 13,7 cm, W2/1 ~ 1,4 cm). Este novo método, aqui proposto, permite a determinação direta da posição e da largura das ilhas magnéticas, em descargas onde a instabilidade dente de serra encontra-se presente.¶ / In this work, an experimental study of the Electron Cyclotron Emission (ECE) in the TCABR Tokamak, is described. An ECE sweeping heterodyne radiometer, operating in the 50-85 GHz frequency range, was installed, calibrated and used to detect ECE radiation in the second harmonic extraordinary mode from thermal plasma discharges. The noise temperature, amplitude and frequency stability of the radiometer were determined. The frequency bandwidth (horizontal space resolution) was measured. A Gaussian Antenna is used and the gaussian beam waist radius (W0 ~ 1 cm) and the focus position (d ~ 37 cm) were experimentally determined. The focus of the antenna was positioned close to the center of the vacuum vessel. The absolute calibration of the equipment was done and the effect of the diagnostic window was considered (reflections and absorptions). The system can operate in sweeping mode, in order to obtain the radial electron temperature profiles, and also in the single frequency mode to obtain temporal electron temperature profiles with high time resolution. Due to the TCABR accessibility conditions and also to avoid runaway electrons, most of the ECE measurements were obtained in discharges with line electron density between 1.0x10+19 m-3 and 1.5x1019 m-3. For ne > 1.5x1019 m-3 (with B0 = 1.14 T) the cutoff in the ECE radiation was observed. The ECE cutoff was used to determine the radial profile of the electron density and applied to three different situations: discharges with additional gas puffing, with the application of a biasing electrode and in discharges with radio-frequency wave injection. Using a parabolic profile it was observed that, 0.85 < alfa < 1.0 for discharges with additional gas injection or with RF injection, and alfa ~ 0.6 for the electrode biasing experiments. The electron temperature profiles and Mirnov oscillations (f ~ 11.7 kHz) were simultaneously measured in discharges with q (r=0) > 1. The position and the width of the magnetic island were therefore calculated. The results indicate the presence of a dominant tearing mode in rs ~ 9.5 cm and the magnetic island width W ~ 2.0-2.5 cm. These experimental results are in agreement with the theoretical results foreseen by models of heat transport in the presence of magnetic islands. It was also observed that, the position of the magnetic island coincided with the region where the temperature radial profile is approximately flat. In another plasma scenario, with q(r=0) < 1, sawteeth oscillations with a period ~ 0.44 ms, crash time ~ 0.12 ms, inversion radius r ~ 4 cm, were measured. Peculiarities in the Te radial profile associated with the amplitude of Te oscillations, |DeltaTe|, due to the sawtooth instability, were observed. It was verified that the minimum values of the |DeltaTe| profile coincided with the region where the temperature radial profile was approximately flat. These results together with the q(r) profile yielded the following mode numbers (m/n), positions (r) and widths (W) of the magnetic islands: m/n = 4/3 (r ~ 9 cm, W4/3 ~ 0.9 cm), m/n = 3/2 (r ~ 11.8 cm, W3/2 ~ 0.9 cm) and m/n = 2/1 (r ~ 13.7 cm, W2/1; ~ 1.4 cm). A novel method to determine the position and width of the magnetic islands, in discharges with the presence of sawtooth instability, is presented here.
143

Comparação entre a prova tuberculínica e a detecção dos níveis de interferon-gama no diagnóstico da tuberculose latente em receptores de transplante de células-tronco hematopoiéticas / Comparison between tuberculin test and detection of interferon gamma levels in the detection of latent tuberculosis in hematopoietic stem cell transplant recipients

Marina de Oliveira e Souza 10 August 2017 (has links)
O principal fator de risco para tuberculose (TB) em receptores de transplante de células-tronco hematopoiéticas (TCTH) é viver em regiões de alta endemicidade da doença, uma vez que a imunossupressão favorece a reativação da tuberculose latente (TBL). O diagnóstico da TBL pela prova tuberculínica (PT) tem limitações nos imunocomprometidos e testes de detecção de interferon gama podem ser vantajosos. Os objetivos do presente estudo foram comparar a PT com o QuantiFERON® TB-Gold In-Tube (QFT-GIT) no diagnóstico da TBL e determinar a incidência de TB em duas coortes de pacientes submetidos ao TCTH. Duas coortes foram analisadas prospectivamente. Coorte1: receptores de TCTH incluídos desde o período pré-transplante. Coorte 2: receptores de TCTH com doença do enxerto contra o hospedeiro (DECH) crônica em atividade. A PT e o QFT-GIT foram realizados imediatamente após a inclusão em ambas as coortes. Pacientes na coorte 1 com diagnóstico de TBL receberam profilaxia com isoniazida (INH) por nove meses. Na coorte 2, os pacientes foram acompanhados clinicamente, sem receber profilaxia. TB ativa foi investigada prospectivamente de acordo com definição de caso e por coletas periódicas de escarro. Entre os candidatos ao TCTH, a prevalência de TBL detectada pela PT foi de 4,7% e de 7,1% pelo QFT-GIT. Entre os receptores com DECH crônica a prevalência de TBL detectada pela PT foi de 5,3% e de 12,5% pelo QFT-GIT. A comparação entre as técnicas revelou boa concordância (kappa=0.60). Não houve casos de TB na coorte 1. A incidência cumulativa de TB na coorte 2 foi de 3%. Em comparação com alguns estudos, nossos resultados apresentaram menor prevalência de TB, com menos resultados indeterminados pelo QFT-GIT e melhor concordância entre ambos os testes. É provável que a introdução de profilaxia com INH seja benéfica também para os pacientes com DECH crônica. / The main risk factor for tuberculosis (TB) in hematopoietic stem cell transplant recipients (HSCT) is to live in regions of high endemicity of the disease, since immunosuppression favors the reactivation of latent tuberculosis infection (LTBI). The diagnosis of LTBI by the tuberculin test (TT) has limitations in the immunocompromised hosts and the interferon gamma release assays (IGRAs) may be advantageous. The objectives of the present study were to compare the TT with QuantiFERON® TB-Gold In-Tube (QFT-GIT) in the diagnosis of LTBI and to determine the incidence of TB in two cohorts of patients undergoing HSCT. Two cohorts were analyzed prospectively. Cohort 1: HSCT recipients included since the pre-transplant period. Cohort 2: TCTH recipients with active chronic graft versus host disease (GVHD). TT and QFT-GIT were performed immediately after inclusion in both cohorts. Patients in cohort 1 with diagnosis of LTBI received prophylaxis with isoniazid (INH) for 9 months. In cohort 2, the patients were followed up clinically, without receiving prophylaxis. Active TB was investigated prospectively according to a case definition criteria and periodic sputum sampling. Among the HSCT candidates, the prevalence of LTBI detected by TT was 4.7% and 7.1% by QFT-GIT. Among the recipients with chronic GVHD, the prevalence of LTBI detected by TT was 5.3% and 12.5% by QFT-GIT. The comparison between the techniques showed good agreement (kappa = 0.60). There were no cases of TB in cohort 1. The cumulative incidence of TB in cohort 2 was 3%. Compared with some studies, our results showed a lower prevalence of LTBI, with less indeterminate results by QFT-GIT and better agreement between both tests. It is likely that prophylaxis with INH is also beneficial for patients with chronic GVHD.
144

Contraste iodado em tomografia computadorizada : reações adversas imediatas em pacientes hospitalizados

Juchem, Beatriz Cavalcanti January 2005 (has links)
Pesquisa quantitativa do tipo exploratório-descritivo, prospectivo, de caráter não experimental. O objetivo consistiu em conhecer as reações adversas imediatas ao contraste iodado intravenoso em pacientes internados, submetidos a tomografia computadorizada num hospital escola, sendo campo do estudo a Unidade de Tomografia do Hospital de Clínicas de Porto Alegre. A coleta de dados ocorreu através de planilha de registros preenchida pela equipe de enfermagem atuante na Unidade, durante as 24 horas de funcionamento do setor, no período entre outubro e dezembro de 2004, totalizando 351 pacientes observados. Os registros incluíram dados relativos à dinâmica do exame, características da clientela e ocorrência dos eventos em estudo. Para o tratamento dos dados, recorreu-se à estatística descritiva e descritiva, com emprego dos softwares SPSS, EPI INFO e PEPI. Os eventos adversos foram considerados imediatos quando ocorreram até 30 minutos após a injeção do contraste. Durante o período do estudo, todas as reações adversas apresentaram intensidade leve, manifestando-se com freqüência de 12,5% entre os 160 pacientes que receberam contraste iodado iônico e 1,0% entre os 191 pacientes que receberam contraste não iônico (p=0,000). O emprego do meio não iônico mostrou-se eficaz na prevenção de reações adversas ao contraste iodado, mesmo na presença de condições clínicas que aumentam o risco para ocorrência desses eventos. A administração intravenosa do contraste através de bomba injetora aumentou significativamente o percentual de reações adversas, em comparação com a injeção manual (p=0,013). O extravasamento de contraste, considerado um evento adverso local, ocorreu em 2,2% das 317 injeções em veia periférica, e os volumes extravasados oscilaram entre 1 e 15 mililitros, com média equivalente a 4,4 mililitros, não ocasionando complicações em nenhum dos casos. A administração intravenosa de contraste através de cateter plástico ocasionou freqüência significativamente menor de extravasamentos do que o emprego de agulha metálica (p=0,041). Os índices evidenciados no presente estudo encontram-se dentro dos limites que constam na revisão de literatura, apesar das pesquisas internacionais apresentarem diferenças entre si na seleção das amostras ou critérios para definição das reações adversas imediatas. Entre as recomendações, sugere-se que os serviços de tomografia conheçam as próprias taxas de reações adversas ao contraste iodado e as condições em que elas ocorrem, a fim de obter evidências para avaliação dos respectivos processos assistenciais. / Investigación cuantitativa del tipo exploratorio-descriptivo, prospectivo, de carácter no experimental. El objetivo consistía en conocer las reacciones adversas inmediatas al contraste yodado intravenoso en pacientes internados, sometidos a tomografía computarizada en un hospital escuela, siendo el campo de estudio la Unidad de Tomografía del Hospital de Clínicas de Porto Alegre. La recolección de datos ocurrió a través de planilla de registros completada por el equipo de enfermería que actúa en la Unidad, durante las 24 horas de funcionamiento del sector, en el período entre octubre y diciembre de 2004, totalizando 351 pacientes observados. Los registros incluían datos relativos a la dinámica del examen, características de la clientela y ocurrencia de los eventos en estudio. Para el tratamiento de los datos, se utilizó la estadística descriptiva y analítica, con empleo de los softwares SPSS, EPI INFO e PEPI. Los eventos adversos fueron considerados inmediatos cuando tuvieron lugar hasta 30 minutos después de la inyección del contraste. Durante el período del estudio, todas las reacciones adversas presentaron intensidad leve, manifestándose con una frecuencia del 12,5% entre los 160 pacientes que recibieron contraste yodado iónico y del 1,0% entre los 191 pacientes que recibieron contraste no iónico (p=0,000). La utilización del medio no iónico se mostró eficaz en la prevención de reacciones adversas al contraste yodado, aún en la presencia de condiciones clínicas que aumentan el riesgo para ocurrencia de esos eventos. La administración intravenosa del contraste a través de bomba inyectora aumentó significativamente el porcentaje de reacciones adversas, en comparación con la inyección manual (p=0,013). La extravasación del contraste, vena periférica, y los volúmenes extravasados oscilaron entre 1 y 15 mililitros, con promedio equivalente a 4,4 mililitros, no ocasionando complicaciones en ninguno de los casos. La administración intravenosa de contraste a través de catéter plástico ocasionó frecuencia significativamente menor de extravasaciones que el empleo de aguja metálica (p=0,041). Los índices evidenciados en el presente estudio se mantuvieron dentro de los límites que constan en la revisión de literatura, a pesar de que las investigaciones internacionales presentan diferencias entre sí en la selección de las muestras o criterios para definición de las reacciones adversas inmediatas. Entre las recomendaciones, se sugiere que los servicios de tomografía conozcan los propios índices de reacciones adversas al contraste yodado y las condiciones en que ocurren, con la finalidad de obtener evidencias para evaluación de los respectivos procesos asistenciales.
145

Modelos Não Lineares Generalizados com Superdispersão

Terra, Maria Lídia Coco, Cysneiros, Audrey Helen A 31 January 2013 (has links)
Submitted by Danielle Karla Martins Silva (danielle.martins@ufpe.br) on 2015-03-12T14:03:12Z No. of bitstreams: 2 TeseDoutoradoMariaLidia.pdf: 1307418 bytes, checksum: f88f918ecc9fbd62d6fddde58ecb741f (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-12T14:03:12Z (GMT). No. of bitstreams: 2 TeseDoutoradoMariaLidia.pdf: 1307418 bytes, checksum: f88f918ecc9fbd62d6fddde58ecb741f (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2013 / CAPES / Dey et al. (1997) propuseram uma classe de modelos que permite a introdução de um segundo parâmetro que controla a variância independentemente da média através de um modelo de regressão, chamada modelos lineares generalizados com superdispersão. Nesta tese, estendemos a classe de modelos proposta por Dey et al. (1997) permitindo que as funções de ligações da média e da dispersão possam ser funções não lineares obtendo expressões matriciais para os fatores de correção Bartlett e tipo-Bartlett para as estatísticas da razão da verossimilhanças e escore, respectivamente, na classe dos modelos não lineares generalizados com superdispersão (MNLGSs). Foi realizado um estudo de simulação para avaliar os desempenhos dos testes baseados nas estatísticas da razão de verossimilhanças e escore com suas respectivas versões corrigidas (Bartlett e tipo-Bartlett) com relação ao tamanho e poder em amostras de tamanhos finitos. Propomos também técnicas de diagnósticos para os MNLGSs, tais como: Alavancagem generalizada, Distância de Cook e Influência local. Finalmente, um conjunto de dados reais é utilizado para avaliar nossos resultados teóricos
146

Aquisição eletrocardiográfica em equinos: definindo uma nova e mais adequada metodologia para a espécie / Equine electrocardiographic acquisition: defining a new and most adequate methodology for the species

Cássia Fré da Costa 05 December 2017 (has links)
INTRODUÇÃO: Vários sistemas de derivações eletrocardiográficas são utilizados na espécie equina e os principais incluem o método de Einthoven, o Ápice-base e o Dubois. O intuito desses sistemas é de captar ondas e complexos de modo que o processo de condução elétrica seja avaliado de maneira eficaz. A disposição dos eletrodos pela metodologia de Dubois tenta posicionar o coração do equino no meio de um triângulo virtual dentro do tórax, assim como descrito por Einthoven, que se baseou no modelo humano. Entretanto, ao se fazer um paralelo com o posicionamento desses eletrodos no ser humano é possível verificar que, apesar da centralização do coração do equino no triangulo virtual, as referências de direita e de esquerda não são respeitadas. Este fato é explicado pela relação entre o ventrículo direito e o ventrículo esquerdo, que nos equinos e outros animais domésticos (na maioria quadrúpedes) se faz no sentido crânio-caudal, enquanto que a posição do coração dentro do tórax do ser humano (bípede) é predominantemente no sentido ântero-súpero-póstero-inferior. OBJETIVOS: O objetivo primário desta tese é o estabelecimento de uma nova e mais adequada metodologia de aquisição eletrocardiográfica para a espécie equina e o objetivo secundário é usar as medidas das variáveis eletrocardiográficas aqui encontradas como valores de referência para essa espécie. MATERIAIS E MÉTODOS: Foram utilizados 22 cavalos da raça Puro Sangue Inglês, sendo 11 fêmeas e 11 machos, com idades variando entre 2 e 5 anos, residentes do Jockey Club de São Paulo, Brasil. Foram realizados 2 eletrocardiogramas sequenciais em cada animal, sendo o primeiro pelo método de Dubois e o segundo de acordo com a nova metodologia aqui instituída, a qual foi nomeada de método Fré. Foi realizado ecocardiograma prévio em todos os equinos e estudo Holter em quatro animais do experimento, os quais foram submetidos à análise de TWA. RESULTADOS: Pelo eletrocardiograma, foi constatado que as derivações esquerdas do plano frontal (DI e aVL) apresentaram complexo QRS de maior duração e amplitude pela nova metodologia e o inverso ocorreu nas derivações inferiores (DII, DIII e aVF), com p < 0,0001. CONCLUSÃO: O método Fré proposto neste estudo mostrou ser mais adequado, quando comparado ao método de Dubois, na obtenção dos fenômenos elétricos cardíacos que ocorrem nos animais da espécie equina. As medidas eletrocardiográficas obtidas pelo método Fré podem ser usados como referência de valores normais para a espécie equina / INTRODUCTION: Many electrocardiographic methods are used for the equine species, among which the most used include Einthoven, Base-apex and Dubois lead systems. They aim to capture waves and complexes to evaluate the process of electric heart conduction in the most effective way. Placement of the electrodes by the Dubois lead system attempts to position the equine heart at the center of a virtual triangle inside the animal\'s thorax, as described by Einthoven, who based his system on the human model. However, in attempting to make a parallel with the positioning of electrodes in the human torso, it is possible to find out that, despite the centralization of the equine heart inside the virtual triangle, the references of right and left are not respected. This can be explained by the relationship between the right and left ventricles, which in the equines and pets (mostly quadrupeds) is done in the cranio-caudal direction, while the position of the heart inside the human thorax (biped) determines that this relationship is predominantly in the anterior-superior-posterior-inferior direction. OBJECTIVES: The primary objective of this thesis is the establishment of a new and most suitable methodology of electrocardiographic acquisition in equines and the secondary objective is the establishment of the electrocardiographic variables thus obtained as reference for this species. MATERIALS AND METHODS: Twenty-two Thoroughbred horses were used, 11 females and 11 males, aged 2 to 5 years old, all reared at the São Paulo Jockey Club, Brazil. Two sequential electrocardiograms were recorded from each animal, the first according to the Dubois lead system and the second according to the new methodology here suggested, which was denominated Fré lead system. All the horses had a previous echocardiogram recorded, in addition to a Holter-ECG obtained from four animals of this experiment, which were subjected to TWA analysis. RESULTS: Through the electrocardiogram it was observed that the values obtained in the left leads of the frontal plane (DI and aVL) showed a larger and taller QRS complex by the new methodology, the reverse happening with the inferior leads such as DII, DIII and aVF, with p < 0,0001. CONCLUSION: The Fré lead system proposed here is more suitable when compared to the Dubois lead system to acquire the cardiac electric phenomena in equines. Electrocardiographic measurements obtained by the Fré lead system can be used as normal reference values for equines
147

Análises genéticas em sistemas microfabricados / Genetic analysis in microfabricated systems

Gabriela Rodrigues Mendes Duarte 30 July 2010 (has links)
A produção de microssistemas de análises totais (&micro;TAS) tem sido objeto de esforços intensos pela comunidade científica. A necessidade de produção de uma plataforma que realize extração, amplificação e separação de DNA--um verdadeiro \"lab on a chip\"--é impulsionada pelas vantagens associadas com as análises em plataformas miniaturizadas. Esta Tese foca no desenvolvimento de métodos para análises de DNA em dispositivos microfluídicos que podem ser associados em &micro;TAS. Inicialmente, foi feito o desenvolvimento de um novo método de extração em fase sólida em que a eficiência de extração depende da manipulação magnética das partículas e não do fluxo da solução através da fase sólida. A utilidade desta técnica em isolar DNA puro de alta qualidade (amplificável) a partir de uma amostra biológica complexa foi demonstrada através da purificação de DNA a partir de sangue total e a subsequente amplificação do fragmento do gene &beta;-globina. A técnica descrita é rápida, simples e eficiente, permitindo uma recuperação de mais de 60% de DNA a partir de 600 nL de sangue em concentração suficiente para amplificação via reação em cadeia da polimerase (PCR). Após o desenvolvimento da extração dinâmica de DNA em fase sólida (dSPE) em microchip de vidro, o método foi adaptado para o uso em microchips de poliéster-toner (PT). Além da extração, a amplificação e separação de DNA também foram realizadas em microchips de PT. O processo convencional de fabricação dos dispositivos de PT produz canais com 12 &micro;m de profundidade. Este trabalho descreve um novo processo de fabricação dos microchips de PT com canais mais profundos. Uma cortadora a laser de CO2 é usada para definir a estrutura desejada no filme de poliéster recoberto com toner. Estes filmes de poliéster recobertos com toner e os canais recortados são utilizados com partes intermediárias no microchip. A tampa e a base (filmes de poliéster) são laminadas juntamente com as partes intermediárias. Desta forma microchips com canais mais profundos podem ser criados. Microchips com 4 filmes de poliéster (base, tampa, e dois filmes centrais) foram utilizados para realizar dSPE. Estes microchips possuem canais com ~270 &micro;m de profundidade. A dSPE adaptada para os microchips de PT demonstrou ser capaz de extrair eficientemente DNA (~65%), e o DNA purificado apresentou qualidade suficiente para PCR. A PCR realizada em microchips de PT demonstrou que os dispositivos de PT são compatíveis com os reagentes da PCR e o sucesso da reação de PCR foi demonstrado através da amplificação do fragmento de 520 pares de bases do &lambda;-DNA. A possibilidade de manipular diferentes soluções que são necessárias para realizar a extração e a PCR demonstra o grande potencial desta plataforma para realizar análises genéticas. Além da extração e amplificação, a separação também foi demonstrada nos dispositivos de PT. Duas integrações foram feitas nos microchips de PT, dSPE-PCR e PCR-separação. Na primeira integração a dSPE e PCR foram realizadas em uma única câmara, e a amplificação do fragmento de 520 pb do &lambda;-DNA foi demonstrada. Na segunda integração, o dispositivo foi fabricado com espessuras diferentes para os diferentes domínios. No domínio da PCR as câmaras possuem profundidade de ~270 &micro;m de profundidade, e para o domínio da eletroforese os canais apresentam 12 &micro;m de profundidade. A integração realizada sem válvulas foi demonstrada através da amplificação e detecção do fragmento de 520 pb do &lambda;-DNA em um mesmo microchip. Este trabalho demonstra o grande potencial dos microchips de PT para produzir dispositivos descartáveis totalmente integrados para análise genética. / Efforts to develop a microfluidic-based total analysis system (&micro;TAS) have been intense in the scientific community. The goal of achieving a device comprising DNA extraction, amplification, and detection in a single device, a true \"lab on a chip,\" is driven by the substantial advantages associated with such a device. This Thesis focus on development of methods for DNA analysis on microdevices, that can be associated with &micro;TAS. Sequentially, the first step was the development of a novel solid-phase extraction technique in which DNA is bound and eluted from magnetic silica beads in a manner that efficiency is dependent on the magnetic manipulation of the beads and not on the flow of solution through a packed bed. The utility of this technique in the isolation of reasonably pure, PCR-amplifiable DNA from complex samples is shown by isolating DNA from whole human blood, and subsequently amplifying a fragment of the &beta;-globin gene. The technique described here is rapid, simple, and efficient, allowing for recovery of more than 60% of DNA from 600 nL of blood at a concentration which is suitable for PCR amplification. The second step was the use of polyester-toner (PT) microchips for DNA analysis (extraction, PCR and separation). The laser-printing of toner onto polyester films has been shown to be effective for generating PT microfluidic devices with channel depths on the order of 12 &micro;m. We describe a novel and innovative process that allows for the production of multilayer PT microdevices with substantially larger channel depths. Utilizing a CO2 laser to create the microchannel in polyester sheets containing a uniform layer of printed toner, multilayer devices can easily be constructed by sandwiching the channel layer between uncoated cover sheets of polyester containing precut access holes. The process allows for the fabrication of channels several hundred microns in depth, with ~270 &micro;m deep microchannels utilized here to demonstrate the effectiveness of multilayer PT microchips for dynamic solid phase extraction (dSPE) and PCR amplification. Dynamic SPE adapted for PT microchip was able to recover more than 65% of DNA from 600 nL of blood and the DNA was compatible with downstream microchip-based PCR amplification. The compatibility of PT microchips was demonstrated by successful amplification of a 520 bp fragment of &lambda;-phage DNA. The ability to handle the diverse chemistries associated with DNA purtification and extraction is a testimony to potential utility of PT microchips beyond separations, and presents a promising new platform for genetic analysis that is low cost and easy to fabricate. Two integrations were carrying out on PT microchip, dSPE - PCR and PCR-ME. The first integration was made in a single chamber and the amplification of 520 bp fragment of &lambda;-phage was demonstrated. The second integration describes a process that allows the production of a multidomain microchip with different channel depths for the different domains for genetic analysis. The final device was made by the conventional sandwiching of the four polyester films of the PCR domain with the two polyester films for the electrophoresis domain. The successful valveless integration of PCR and separation was demonstrated by amplification and detection of a 520 bp fragment of &lambda;-phage DNA. This work shows the enormous potential of PT microchips to be used for total genetic analysis.
148

Métodos de diagnóstico em modelos logísticos trinomiais / Methods of dignóstics in trinomials Logistic models

Jose Alberto Pereira da Silva 10 October 2003 (has links)
Os modelos logísticos trinomiais podem ser interpretados como uma extensão natural do modelo logístico binomial para situações em que a resposta admite apenas três resultados. Introduzimos inicialmente os modelos logísticos trinomiais e discutiremos em seguida alguns aspectos inferenciais, tais como estimação e testes. Medidas de qualidade do ajuste são também apresentadas. Contudo, o principal foco deste trabalho é a apresentação de métodos de diagnóstico. Mostramos que as técnicas usuais de diagnóstico desenvolvidas para o modelo logístico binomial podem ser adaptadas para o caso trinomial. O desenvolvimento de métodos diretos para o modelo logístico trinomial é mais complexo do ponto de vista computacional, embora seja sempre possível. Discutimos alguns desses métodos, dentre os quais, o desenvolvimento de resíduos, de métodos para detectar pontos de alavanca, métodos de deleção de pontos e influência local. Comparamos os métodos adaptados com alguns métodos diretos através de exemplos. / The trinomial logistic models can be interpreted as a natural extension of the traditional binomial logistic model to situations in which the response allows only three possible results. We firts introduce the trinomial logistic modles and then some inferential aspects, such as estimation and hypothesis testing are discussed. Good-of-fit measures are also given. However, the aim of this work is the presentation of some diagnostic procedures for trinomial logistic models. We show that methods developed for binomial logistic models can adapted straightforward for trinomial models. The developement of direct methods, even though possible, in general requires more complex calculation. Some of these direct methods, suchs as evaluation of residuals, measures of high leverage points, deletion methods and local influence are apresented. Coparisons between adapted and direct methods are made via examples with real data.
149

Avaliação dos ruidos articulares como diagnóstico complementar de desordens temporomandibulares / Assessment of temporomandibular joint sounds as a complementary diagnosis in temporomandibular disorders

Marcus Vinicius Yamazato Kanashiro 02 September 2011 (has links)
O ruído articular é comumente reconhecido como um sinal de desarranjo articular, e a sua análise faz parte do conjunto de dados coletados em vários sistemas de classificação e diagnóstico, tanto em pesquisas como nas atividades clínicas. Apesar desta importância, existe ainda dificuldade na interpretação dos sons, em virtude da variação natural do fenômeno, do subjetivismo por parte de examinadores e dos métodos e equipamentos empregados para o diagnóstico. Visando uma análise mais objetiva, foi desenvolvido um dispositivo para gravar e analisar graficamente os sons. Este método permite o armazenamento e sucessivas análises, eliminando ainda diferenças de percepção de sons entre os examinadores. O objetivo da pesquisa é verificar a eficácia do dispositivo desenvolvido efetuando a comparação com exames de ressonância magnética (RM). A concordância entre os examinadores e as análises das gravações também foram feitas, para se verificar o subjetivismo das percepções. Pacientes com idade entre 14 a 75 anos e que reportaram dor muscular e/ou a presença de sons articulares foram incluídos na pesquisa. Foram excluídos aqueles que já tivessem recebido tratamento prévio, apresentassem dores de cabeça, infecções, traumas faciais recentes, patologias sistêmicas, gravidez ou marca passos. De acordo com estes critérios, uma amostra de 18 pacientes foi selecionada para a pesquisa. Os pacientes tiveram os ruídos articulares detectados com o método de palpação e por estetoscópios , por quatro examinadores, e os sons então foram gravados e analisados, com o dispositivo desenvolvido. Por fim, as percepções dos sons por todos os métodos realizados na pesquisa foram aplicadas ao protocolo RDC/TMD, e diagnósticos para cada paciente foram obtidos. Desta forma, foi feita a comparação com os exames de ressonância magnética (RM), adotado como padrão ouro na pesquisa. O critério estatístico de Altman mostrou uma concordância em termos de valores de kappa muito baixa entre os quatro examinadores. Nos ciclos de abertura, de acordo com os resultados obtidos no estudo, o examinador 2 (método de palpação) apresentou uma fraca concordância com os examinadores 3 e 4, (método de estetoscópios), (k=0.272 e k=0.397, respectivamente). O examinador 3 apresentou uma boa concordância com o examinador 4 (k=0.698). Nos ciclos de fechamento, o examinador 3 apresentou uma fraca concordância com o examinador 4 (k=0.398). Na comparação entre as gravações e os examinadores, verificou-se a falta de concordância entre estes, com valores de kappa muito baixos, quando possíveis de serem calculados (k=0.021 até k=0.147). Quando os diagnósticos obtidos pelo RDC/TMD por todos os métodos foram comparados com os laudos de RM, a gravação apresentou melhor percentual de concordância (55,6%), em relação à percepção de som pelos examinadores (36,1% a 52,8%). O dispositivo desenvolvido para análise e gravação dos ruídos articulares mostrou ser um método de fácil manuseio e visualização, conseguindo uma superior detecção de ruídos. A comparação com exames de RM confirmou esta melhora. / The joint noise is commonly recognized as a sign of an articular derangement, and its analysis is part of the data set collected in many systems of classification and diagnosis, both in research and clinical activities. Despite this importance, there is some difficulty in interpreting the sounds due to the natural variability of the phenomenon, subjectivism by examiners and the methods and equipments used for diagnosis. In order to get a more objective analysis, we developed a device to record and graphically analyze the sounds. This method allows the storage and subsequent analysis, even eliminating differences in perception of sound between the examiners. The present research aims to verify the effectiveness of the device developed by comparisons with magnetic resonance imaging (MRI). The agreement between the examiners and the analysis of the recordings were also made to verify the subjectivity of perception. Patients aged 14 to 75 years who reported muscle pain and / or the presence of joint sounds were included in the survey. We excluded those who had already received previous treatment, experience headaches, infections, recent facial trauma, systemic diseases, and pregnancy or pacemakers users. According to these criteria, a sample of 18 subjects was selected for the survey. The patients had joint noises detected with the methods of palpation and stethoscope by four examiners, and the sounds were recorded and then analyzed with the developed device. Finally, perceptions of the sounds made by all methods were applied in the research protocol RDC / TMD, and diagnoses for each patient were obtained. Finally, the comparison was made with magnetic resonance imaging (MRI), adopted as the gold standard in research. From the results, according to Altman criteria, there was an agreement in terms of very low kappa values among the four examiners. In cycles of opening, according to the results obtained in the study, the examiner 2 (palpation method) showed a poor agreement with the examiners 3 and 4 (method of stethoscopes), (k = 0272 k = 0397, respectively). The examiner 3 had good agreement with the examiner 4 (k = 0698). In closing cycles, the examiner 3 had a poor agreement with the examiner 4 (k = 0398). In the comparison between the recordings and the examiners, there was a lack of agreement among these, with very low kappa values when possible to be calculated (k = k = 0021 to 0147). When the diagnoses obtained by RDC / TMD by all methods were compared with the findings of MRI, the recording method showed the best percentage of agreement (55.6%) compared to the perception of sound by the examiners (36.1 to 52%, 8%). The device developed for recording and analyzing the joint sounds proved to be an easy method of handling and display, achieving a better detection of the noise. The comparison with MRI confirmed this improvement.
150

Estudos experimentais em configuração a campo reverso no T.C.-I / Experimental Studies Configuration Reversed Field T.C.-I

Emilia Akemi Aramaki 11 December 1992 (has links)
Neste trabalho, foi realizado um estudo experimental detalhado sobre a fase de formação da configuração a campo reverso, no dispositivo denominado T.C.-I da UNICAMP, com a utilização de dignósticos ópticos passivos em plasmas de hélio e hidrogênio. Para cada tipo de gás, os valores do campo de polarização, pré-ionização com temporização do crowbar e pressão de trabalho foram variados para estudar os mecanismos de formação da configuração reversa de campo, através dos diagnósticos da emissão do plasma, complementados com sondas elétricas e magnéticas, externas e internas. Para a obtenção das condições ótimas de operação da máquina, a chave crowbar, construída no próprio Laboratório de Plasma da UNICAMP, demonstrou ser bastante confiável para essa finalidade, pois o tempo entre o final da pré-ionização e o início da descarga principal era um fator importante para uma boa dinâmica de implosão, sem a interferência das oscilações da pré-ionização sobre a fase principal. Nas operações com o plasma de hélio, a melhor pressão de operação do gás foi de 18 mTorr, obtida através das intensidades da linha de HeII (4686 Â), fotodiodos, copo de Faraday e diagnósticos de fluxo excluído. Os valores típicos da densidade e temperatura obtidos foram de 3.2 x 1015cm-3 e 77 eV respectivamente . O raio da separatriz foi de 2.5 cm, durante 1.5us, decaindo rapidamente após a formação da CCR. As medidas espectrais de HeII e OII(4699Â) no plasma de hélio levaram às temperaturas iônicas de 73 a 180 eV, para uma varredura de pressão de 3.8 a 18 mTorr . Em alguns casos, parece provável ter ocorrido efeitos Stark devido a aquecimentos turbulentos atribuídos a campos elétricos microscópicos de 58 kV/cm. Nas operações com hidrogênio , basicamente todos os processos usados para o plasma de hélio foram mantidos. As linhas espectrais analisadas foram Ha, OII, NII, NIII, CIII, CIV e SiIV, tendo sido obtido, a partir das linhas de impurezas, temperaturas iônicas no centro do plasma , mais altas que as do plasma de hélio . Além disso, as temperaturas fornecidas pelas linhas de potencial de ionização mais altos, como o CIII, CIV, SiIV foram maiores que as obtidas com NII ou NIII. Nesta fase, a temperatura e densidades obtidas para a pressão de 3.3 mTorr foram respectivamente 220 eV e 2.9 X1015cm-3. Semelhantemente ao caso do hélio, algumas descargas apresentaram fenômenos prováveis de efeito Stark, tendo sido estimado um campo elétrico microscópico de 21.8 kV/cm . Verificou-se que a influência de sondas magnéticas no interior do plasma é bastante crítica, produzindo uma queda de temperatura de 235 eV para 139 eV na presença da sonda, quando medido com a linha do NIII e de 532 eV para 253 eV quando obtidas com linhas de CIII e SilV. O raio de separatriz estimado para a pressão de operação de 3.3 mTorr foi de 2.2 em com tempo de vida de 3.0 us. Foi ainda observado um novo modo de operação, com a obtenção de modos rotacionais n=4, observados usualmente em pressões de operação mais altas, de 6 a 35 mTorr. / A detailed experimental study of the formation phase in field reversed configuration device T.C.-I at UNICAMP has been carried out for the first time, using passive optical diagnostics on helium and hidrogen gas plasmas. For each type of gas, the values of bias polarization field, pre-ionization with crowbar timing and gas fill pressure have been varied to study field reversed configuration formation mechanism by using plasma emission diagnostics supported by magnetic and electric external and internal multi array probes. For the machine operation condition results, the use of crowbar switch, built at UNICAMP Plasma Laboratory, has shown very reliable operation, where the interval timing between the end of pre-ionization and main discharge phase played important role on good implosion dynamics with no influence of the pre-ionization bank RLC oscillation into the main phase. In the helium plasma operation, the best fill pressure of 18mTorr was obtained using HeII ( 4686Â) spectrum line, photodiode Faraday cup, IMACON, excluded flux diagnostics. The typical density and temperature estimated were 3.2x1015cm-3 e 75 eV respectively. The separatrix radius of 2.5 cm was obtained for 1.5us, decaying soon after the FRC formation. The spectral measurements of HeII, 0II (4699Â) in helium plasma have shown ion temperatures from 73 eV to 180 eV when the pressure is varied from 3.8 to 35 mTorr. In some cases, probable Stark effects due to turbulent heating during implosion also were observed, attributed to 58 kV/cm microscopic electric field. In the hydrogen plasma operation, basically all the process used in helium plasma also were carried out. The spectral line analyzed were Ha\' OII,NII, NIII, eIII, eIV, SiIV, having been obtained temperatures higher than helium plasma in the center of the plasma, using the impurities line. Furthermore, the ion temperatures from higher ionization potential lines (eIII, eIV, SiIV) were higher than temperatures obtained by NII or NIII lines. The average temperature calculated from NII and NIII spectral line was 220 eV and the density for hydrogen plasma was 15 -3 of 2.9 x 10 cm. The influence of internal magnetic probes was very critical, dropping the ion temperature from 235 eV to 139 eV in the presence of probe, when the temperature is calculated through NIII line or from 532 to 253 eV for eIII and SiIV line calculation. Like the helium plasma, in this case also one has been observed a probable Stark effect, attributed to 21.8 kV/cm microscopic electric field. The separatrix radius estimated for fill pressure of 3.3 mTorr was 2.2 cm with the life time of 3.0us interrupted by decaying of external field. We also observed a new plasma mode operation of n=4, usually present at high fill pressure, from 6 mTorr to 35m Torr.

Page generated in 0.0872 seconds