• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • 1
  • Tagged with
  • 16
  • 16
  • 10
  • 10
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Comportamento de contaminantes metálicos em eventos de ressuspensão de sedimentos portuários e estuarinos tropicais

Monte, Christiane do Nascimento 06 February 2018 (has links)
Submitted by Biblioteca de Pós-Graduação em Geoquímica BGQ (bgq@ndc.uff.br) on 2018-02-06T14:17:14Z No. of bitstreams: 1 Tese Christiane Monte 2017.pdf: 1803168 bytes, checksum: fcf5354cecebc3cc273db52007aaab5e (MD5) / Made available in DSpace on 2018-02-06T14:17:14Z (GMT). No. of bitstreams: 1 Tese Christiane Monte 2017.pdf: 1803168 bytes, checksum: fcf5354cecebc3cc273db52007aaab5e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Universidade Federal Fluminense. Instituto de Química. Programa de Pós-Graduação em Geoquímica, Niterói, RJ / RESUMO A ressuspensão sedimentos pode alterar a biodisponibilidade dos contaminantes metálicos, podendo colocar em risco a biota. Esta hipótese foi testada em duas Baías – Guanabara e Sepetiba, no Rio de Janeiro, sendo a Guanabara dividida em cinco áreas. Em ambas as Baías há contaminação por metais-traço, na Guanabara um dos principais problemas é a contaminação dos sedimentos por Hg, enquanto na de Sepetiba é por Cd e Zn, ambas a Baías recebem efluentes domésticos e industriais. Assim, o objetivo geral deste estudo foi avaliar os efeitos da ressuspensão de sedimentos na região do Saco do Engenho (Baía de Sepetiba) e os estuários dos rios Meriti e Iguaçu, os Portos do Rio e de Niterói e a APA de Guapimirim (Baía de Guanabara) e o possível aumento da biodisponibilidade de metais-traço (Cd, Cu,Fe, Hg, MeHg, Mn, Ni, Pb e Zn). Em Sepetiba foram coletadas 12 amostras próximas ao Saco do Engenho, e foram submetidas a dois intervalos de tempo de ressuspensão (1h e 24h). Grandes concentrações de Zn e Cd foram encontradas na região, com o resultado da extração sequencial HCl 1 mol L-1 e após o método US EPA 3051 foi aplicado o índice de mudança na biodisponibilidade (BCI) que mostrou-se ser uma boa ferramenta no monitoramento do risco de sedimentos contaminados por metais associados à atividade de dragagem. Na Baía de Guanabara foram cinco pontos, um para cada área com três réplicas e foram submetidas a seis intervalos de ressuspensão ( 30min, 1h, 3h, 6h,12h e 24h). O Hg e o MeHg foram determinados em duas áreas da Baía (Meriti e Porto do Rio) e apesar das concentrações serem maiores no Meriti, o percentual de metilação foi quatro vezes maior no Porto Rio em relação ao Meriti, sendo a matéria orgânica e a granulometria, os reguladores da dinâmica do Hg. No estuário do Rio Iguaçu, foi aplicado o mesmo tipo de extração sequencial aplicado em Sepetiba e com apenas dois intervalos de ressuspensão (1h e 24h), e os resultados mostraram variação no gradiente estuarino e aumento na biodisponibilidade dos contaminantes metálicos após a ressuspensão. Foram realizados bioensaios terrestres com os sedimentos das cinco áreas da Baía de Guanabara com oligoquetas terrestres da espécie Eiseinia andrei , os bioensaios mostraram que os metais regulam a mortalidade das oligoquetas para quatro áreas, e há a influência da sazonalidade na mortalidade das oligoquetas, assim como a influência da espacialização dentro da Baía. Entretanto, na área menos contaminada houve a menor concentração letal 50% (CL50), que provavelmente foi provocada por outro fator, assim como houve o engordamento dos animais após a exposição, que pode estar relacionado à salinidade da região o outro fator desconhecido. Em Sepetiba, os resultados evidenciam que a ressuspensão afeta a biodisponibilidade de diferentes metais, principalmente no primeiro intervalo de tempo (1 hora), refletindo mudanças abruptas em função da exposição a condições oxidantes. Na Guanabara, houve uma oscilação entre os intervalos, entretanto para o MeHg no Porto do Rio houve metilação a partir do intervalo de 3h. / The resuspension of sediments can change the bioavailability of mettalic contaminants, could increase risk to biota. This hypothesis was tested in two bays- Gananbara and Sepetiba, in Rio de Janeiro, being the Guanabara divided into five areas. In both Bays there is contamination by trace metals, in the Guanabara, one of the main is the contamination of sediments by Hg, while Sepetiba, it’s for Cd and Zn, both bays receives domestics and industrial sewage. Therefore, the general aims of this study was evaluate the effects of resuspension of sediments in Saco do Engenho area (Sepetiba Bay) e and estuaries of Meriti and Iguaçu river, the ports of Rio and Niterói and Protect Area of Guapimirim ( Guanabara Bay) and the possible increase of bioavailability of trace metals(Cd, Cu,Fe, Hg, MeHg, Mn, Ni, Pb e Zn).In Sepetiba were collected 12 samples near to Saco do Engenho, and were submitted to 2 time intervals of resuspension (1h and 24h). Higher concentrations of Zn and Cd were found in the area, with result of sequential extraction HCl 1 mol L-1 and after US EPA 3051 method was applied the bioavailability change index (BCI), which showed to be a good tool to monitoring of risk of contaminated sediments by metals associated to dredging activity. In the Gaunabara Bay were five points, one for each areawith 3 replicated e and were submitted to six time intervals of resuspension( 30min, 1h, 3h, 6h,12h e 24h). The Hg and MeHg were analyzes in two areas of Bay (Meriti and Porto do Rio), and although of concentrations were higher in Meriti, the percentage of methylation was four times higher in port of Rio than Meriti, being, the organic matter and grain size the regulators of Hg dynamics. In the estuary of Iguaçu River, was applied the same type of extraction sequence applied in Sepetiba and with only two time intervals of resuspension(1h e 24h), and the results showed variation in estuarine gradient and increase bioavailabilityof mettalic contaminats after resuspension. Were performed terrestrial bioassays with sediments of five areas of Guanabara Bay with earthworms Eiseinia andrei, the bioassays showed which metals regulates the earthworms mortality for 4 areas, and there is the influence of seasonal in mortality, as influence of specialization into Bay. However, in the area the less contaminated area there was the lowest lethal concentration 50% (LC 50), probably was caused another factor, as there was fattening of animal after exposition, can be associated to salinity of region or unknown another factor. In Sepetiba, the results evidenced the resupension affected the bioavailability of different metals, mainly in the first interval (1 hour), reflecting abrupt changes due to exposure to oxidizing conditions. In the Guanabara, there was one oscillation between time intervals, however for MeHg in port of Rio there was methylation from 3 hours time interval.
12

Avaliação da biodisponibilidade de uma nova formulação de micofenolato mofetil e de um método para sua monitorização terapêutica / Assessment of the bioavailability of a new micophenolate mofetil formulation and a method for therapeutic monitoring

Romano, Paschoalina 08 March 2007 (has links)
O Micofenolato Mofetil (MMF) é amplamente utilizado em transplantes de órgãos sólidos e tem como seu metabólito ativo o ácido micofenólico (MPA). A alta variabilidade intra e interindividual dos níveis plasmáticos de MPA em pacientes transplantados renais que recebem a mesma dose de MMF, a combinação com diferentes imunossupressores que afetam seu metabolismo e a oscilação destes níveis com o tempo decorrido após o transplante justificam a sua monitorização. Pequenas mudanças na dose de MMF podem comprometer a eficácia terapêutica. O objetivo deste trabalho foi avaliar a farmacocinética de duas formulações de MMF. Estudouse um ensaio para a dosagem de ácido micofenólico (MPA) plasmático (EMIT® 2000, Dade Behring) e a seguir, a biodisponibilidade da nova formulação de MMF disponibilizada por Strides Arcolab (MMF-SA), comparativamente ao CellCept® em pacientes transplantados renais estáveis. A metodologia de imunoensaio enzimático (EMIT) apresenta resultados relativamente mais elevados em relação à cromatografia líquida de alta resolução, devido à reação cruzada do metabólito acil glucoronídeo de MPA (AcMPAG) com o anticorpo presente no reagente. O método é capaz de detectar não só o MPA, mas também o seu metabólito ativo AcMPAG, o que pode representar uma vantagem. Comparamos o método EMIT com cromatografia líquida de alta resolução acoplada à espectrometria de massas (LC-MS/MS) e obtivemos r2 = 0,9612. O método apresentou: sensibilidade analítica de 0,02 ± 0,0016ug/mL; limite de detecção de 0,01 ± 0,0015ug/mL; linearidade de 14,58 ± 0,3300ug/mL; coeficientes de variação, intraensaio de 2,14% - 5,09% e interensaio de 4,18% - 5,02%. A estabilidade da amostra foi de 90 dias em temperatura de -20°C. Concluiu-se que a metodologia EMIT para dosagem de MPA é de fácil execução e apresenta boa precisão analítica. Participaram do estudo de biodisponibilidade, vinte e quatro pacientes adultos, transplantados renais, que já recebiam o CellCept® em combinação com Tacrolimus (n = 14), ciclosporina (n= 7) ou sem inibidores de calcineurina (n=3). Todos recebiam prednisona. As duas drogas foram administradas em esquema cruzado, com intervalo de uma semana entre as farmacocinéticas. Neste intervalo, os pacientes continuaram recebendo CellCept®. Foram analisadas as curvas farmacocinéticas de 12 horas para cada uma das duas formulações, nas mesmas doses equimolares. As médias ± SE das medidas de concentração máxima (Cmax) e da área sob a curva (AUC), para CellCept®, não foram estatisticamente diferentes das médias ± SE para MMF-SA (11,29 ± 1,35ug/mL versus 11,05 ± 1,08ug/mL e 49,11 ± 5,15ug.h/mL versus 47,59 ± 3,99 ug.h/mL), respectivamente. Da mesma forma, o intervalo de confiança 90% de MMF-SA / CellCept® para Cmax (93,57% - 121,73%) e para AUC 0-12h (93,75% - 108,90%) ficaram dentro do intervalo de bioequivalência (80% - 125%). Concluímos que CellCept® pode ser substituído com segurança pela formulação MMF-SA genérica em pacientes transplantados renais estáveis. / Mycophenolate mofetil (MMF) is largely used in solid organ transplantation. Mycophenolic Acid (MPA) is the active metabolite of MMF. The high intra and interpatients variability of the MPA plasma levels in transplant recipients under the same dose of MMF, the association with immunosuppressant drugs that change the MPA metabolism and pharmacokinetic parameters over time may cause impact in the optimal dose of MMF. The therapeutic monitoring of MPA may improve the efficacy and safety. The aim of this study was to: 1 -to validate the EMIT assay for MPA monitoring and 2: to assess the bioavailability of two MMF formulations. The performance of the EMIT® 2000 Dade Behring Mycophenolic acid enzimatic immunoassay was evaluated. There was a high correlation between the LC-MS/MS and EMIT (r2 = 0.9612). Because of the cross-reactivity of the antibody used in the EMIT assay with the active acyl glucuronide metabolite (AcMPAG), the EMIT concentrations are higher than those from high performance liquid chromatography (HPLC).The analytic sensitivity was 0.02 ± 0.0016ug/mL; detection limit 0.01 ± 0.0015ug/mL; linearity 14.58 ± 0.3300ug/mL. The CV of within-day precision was 2.14% - 5.09% and the CV of between-days precision was 4.18% - 5.02%. The sample stability was 90 days at - 20°C. The EMIT assay is easily performed and fulfills all the requirements for an assay. We studied the MMF formulation from Strides Arcolab (MMF-SA) and CellCept® in twenty-four adult, renal transplanted patients, receiving MMF (CellCept®), before the bioavailability study, combined with tacrolimus (n = 14), cyclosporine (n = 7) or without CNI (n = 3). All patients received prednisone. They had a 12 hours pharmacokinetics (PK) of total MPA measured after the same equimolar doses for the two formulations. The PK analysis revealed two mean PK curves that overlaid over each other. Mean ± SE of maximum concentration (Cmax) and area under the time-concentration curve (AUC) of CellCept® were not statistically different from the generic MMF-SA (11.29 ± 1.35 ug/mL vs 11.05 ± 1.05 ug/mL and 49.11 ± 5.15 ug.h/mL vs 47.59 ± 3.99 ug.h/mL, respectively). In the same way the MMF-SA/CellCept® 90% confidence interval for both: Cmax (93.57% -121.73%) and AUC0-12h (93.75% - 108.90%) was within the bioequivalence interval (80%-125%). In renal transplanted patients, CellCept® can be switched by the generic MMF formulation.
13

Avaliação de risco informatizado e prevenção primária na assistência à saúde das mulheres da cidade de São Paulo / Evaluation of informed risk and primary prevention in assistance to healthy in women in Sao Paulo

Romano, Patrícia 27 March 2007 (has links)
Introdução: O Programa Global de Avaliação de Risco Informatizado - PAISM, através de um questionário com 91 perguntas, permite prever o risco de 9 grupos importantes de doenças, que afetam as mulheres. O Programa examinou 15.538 mulheres determinando o risco para: câncer de mama, endométrio, colo de útero, ovário e pulmão; osteoporose; endometriose; DST/AIDS e dislipidemias e foram classificadas em baixo, médio e alto risco para estas doenças. Baseado no risco de avaliação, o programa ofereceu para as mulheres conselho individualizado com relação a hábitos e comportamentos. Objetivos: Avaliar os fatores sócio-demográficos, de acordo com diferentes grupos de risco para cada doença; o estilo e hábitos de vida para os riscos de determinadas doenças e o conhecimento da importância da educação para a saúde, o desempenho e a aceitação do programa. Pacientes e Métodos: Foram estudadas retrospectivamente 320 mulheres selecionadas, sem critérios previamente estabelecidos apenas com a condição de ter participado do Programa Global de Avaliação de Risco Informatizado e não ter câncer. A coleta de dados foi realizada a partir de um outro questionário, constituído de 30 questões que foi aplicado no Ambulatório de Ginecologia do Hospital das Clínicas da FMUSP e em ações existentes nas comunidades carentes da região da Cidade de São Paulo. Esta pesquisa foi delineada inicialmente com base em um modelo conceitual-operativo de natureza quantitativa e, posteriormente, qualitativa. Resultados e conclusões: Existem fatores sócio-demográficos e as variáveis atitudinais, que demonstram o estilo de vida da paciente, também, traçam os grupos de alto risco e colaboram para a observação de determinadas doenças. O nível de conscientização das entrevistadas em relação a algumas variáveis de risco é alto, no entanto, essa conscientização nem sempre se reflete em atitudes e esses fatores acabam influenciando o alto risco nas doenças pesquisadas. As entrevistadas afirmam: o programa é bom, o questionário de avaliação é fácil, a interpretação do risco e as orientações de qualidade de vida são muito boas, demonstrando a importância da educação para a saúde. / Introduction: The Global Program of Evaluation of Informed Risks - GPEIR, through one questionnaire with 91 questions, allows foresee the risk of 9 important groups of disease, which affects women. The Program examined 15.538 women determining the risk to: breast cancer, endometrium, uterus col, ovarian and lung; osteoporosis, endometriosis; DST/AIDS and dislipidemias and were classified below, medium and high risk to those illnesses. Based on the risk of the evaluation, this program offered to women individual advises related to habits and behavior. Objectives: Evaluate the socio-demographic factors, in agreement with different groups of risks to each illness; the stile and habits of life to risks of determined illness and the knowledge of the importance of education to healthy, development and acceptation of the program. Patients and methods: 320 women selected had been studied, without criteria established only with the condition of these women have participated in the Global Program of Evaluation of Informed Risks and don\'t have cancer. The collects of data was realized on base of another questionnaire, with 30 questions that were applied in the \"Ambulatório de Ginecologia do Hospital das Clínicas da FMUSP\" and in actions in devoid communities in São Paulo. This research was delineated initially with base on a conceptual-operative model of nature quantity and lately, quality. Results and conclusion: there are socio-demographic factors and variable attitudinal, which demonstrate the stile of life of patients, also, trace the groups of high risk and collaborate to observe determined illness. The level of awareness of the interviewed in relation to some variable of risk is high, however, this awareness nor always reflects in attitudes and this factors finish influencing a high risk on the illness that have been researched. The interviewed affirm: the program is good, the questionnaire is easy, the interpretation of risk and orientations of quality of life are very good, showing the importance of education to healthy.
14

Avaliação de risco informatizado e prevenção primária na assistência à saúde das mulheres da cidade de São Paulo / Evaluation of informed risk and primary prevention in assistance to healthy in women in Sao Paulo

Patrícia Romano 27 March 2007 (has links)
Introdução: O Programa Global de Avaliação de Risco Informatizado - PAISM, através de um questionário com 91 perguntas, permite prever o risco de 9 grupos importantes de doenças, que afetam as mulheres. O Programa examinou 15.538 mulheres determinando o risco para: câncer de mama, endométrio, colo de útero, ovário e pulmão; osteoporose; endometriose; DST/AIDS e dislipidemias e foram classificadas em baixo, médio e alto risco para estas doenças. Baseado no risco de avaliação, o programa ofereceu para as mulheres conselho individualizado com relação a hábitos e comportamentos. Objetivos: Avaliar os fatores sócio-demográficos, de acordo com diferentes grupos de risco para cada doença; o estilo e hábitos de vida para os riscos de determinadas doenças e o conhecimento da importância da educação para a saúde, o desempenho e a aceitação do programa. Pacientes e Métodos: Foram estudadas retrospectivamente 320 mulheres selecionadas, sem critérios previamente estabelecidos apenas com a condição de ter participado do Programa Global de Avaliação de Risco Informatizado e não ter câncer. A coleta de dados foi realizada a partir de um outro questionário, constituído de 30 questões que foi aplicado no Ambulatório de Ginecologia do Hospital das Clínicas da FMUSP e em ações existentes nas comunidades carentes da região da Cidade de São Paulo. Esta pesquisa foi delineada inicialmente com base em um modelo conceitual-operativo de natureza quantitativa e, posteriormente, qualitativa. Resultados e conclusões: Existem fatores sócio-demográficos e as variáveis atitudinais, que demonstram o estilo de vida da paciente, também, traçam os grupos de alto risco e colaboram para a observação de determinadas doenças. O nível de conscientização das entrevistadas em relação a algumas variáveis de risco é alto, no entanto, essa conscientização nem sempre se reflete em atitudes e esses fatores acabam influenciando o alto risco nas doenças pesquisadas. As entrevistadas afirmam: o programa é bom, o questionário de avaliação é fácil, a interpretação do risco e as orientações de qualidade de vida são muito boas, demonstrando a importância da educação para a saúde. / Introduction: The Global Program of Evaluation of Informed Risks - GPEIR, through one questionnaire with 91 questions, allows foresee the risk of 9 important groups of disease, which affects women. The Program examined 15.538 women determining the risk to: breast cancer, endometrium, uterus col, ovarian and lung; osteoporosis, endometriosis; DST/AIDS and dislipidemias and were classified below, medium and high risk to those illnesses. Based on the risk of the evaluation, this program offered to women individual advises related to habits and behavior. Objectives: Evaluate the socio-demographic factors, in agreement with different groups of risks to each illness; the stile and habits of life to risks of determined illness and the knowledge of the importance of education to healthy, development and acceptation of the program. Patients and methods: 320 women selected had been studied, without criteria established only with the condition of these women have participated in the Global Program of Evaluation of Informed Risks and don\'t have cancer. The collects of data was realized on base of another questionnaire, with 30 questions that were applied in the \"Ambulatório de Ginecologia do Hospital das Clínicas da FMUSP\" and in actions in devoid communities in São Paulo. This research was delineated initially with base on a conceptual-operative model of nature quantity and lately, quality. Results and conclusion: there are socio-demographic factors and variable attitudinal, which demonstrate the stile of life of patients, also, trace the groups of high risk and collaborate to observe determined illness. The level of awareness of the interviewed in relation to some variable of risk is high, however, this awareness nor always reflects in attitudes and this factors finish influencing a high risk on the illness that have been researched. The interviewed affirm: the program is good, the questionnaire is easy, the interpretation of risk and orientations of quality of life are very good, showing the importance of education to healthy.
15

Avaliação do perfil de dissolução de comprimidos de prednisona bioequivalentes ao longo do estudo de estabilidade / Evaluation of the dissolution profile of prednisolone tablets bioequivalent throughout the stability study

Toehwé, Leonardo Henrique January 2013 (has links)
Made available in DSpace on 2015-08-19T13:52:54Z (GMT). No. of bitstreams: 2 11.pdf: 3707565 bytes, checksum: 12296eaba653f97c49408b84cc04f255 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2013 / Fundação Oswaldo Cruz. Instituto de Tecnologia em Fármacos/Farmanguinhos. Rio de Janeiro, RJ, Brasil. / As formas farmacêuticas sólidas de uso oral, sobretudo os comprimidos, são as mais utilizadas na terapêutica, pois são de fácil administração e apresentam alta produtividade e um custo relativamente baixo, além de proporcionarem ao fármaco um meio mais estável em relação às formas semi-sólidas e líquidas. No entanto, um medicamento na forma sólida pode sofrer alterações devido à ação de vários fatores como umidade, temperatura, luz e oxigênio do ambiente e pelas características do próprio estado sólido da substância ativa e dos excipientes empregados na formulação. A instabilidade de um fármaco, na forma isolada ou em uma formulação, pode alterar vários parâmetros de qualidade como aspecto, teor, dissolução e perfil de dissolução. O perfil de dissolução de um medicamento é um parâmetro de qualidade que deve ser avaliado durante a produção e estabilidade das formas farmacêuticas sólidas orais, pois a alteração do mesmo durante o período de armazenamento pode alterar a quantidade de fármaco disponível para absorção, podendo comprometer a sua biodisponibilidade e eficácia terapêutica. Nesse estudo o perfil de dissolução de comprimidos de prednisona 20mg bioequivalentes do medicamento referencia e de três formulações teste foram avaliadas, ao longo do estudo de estabilidade. Durante o estudo os comprimidos de prednisona e o insumo farmacêutico ativo(IFA) prednisona de dois diferentes fabricantes foram caracterizado quanto às suas propriedades físicas e físico-químicas. O IFA também foi avaliado quanto a sua permeabilidade em células Caco-2. Os dados obtidos foram utilizados para elaborar um estudo de correlação in vitro-in silico-in vivo e desenvolver estudos de predição de biodisponibilidade in silico. Os resultadospermitiram verificar que os perfis de dissolução entre os comprimidos do medicamento referência e dos lotes teste não se mantiveram equivalentes ao longo do estudo. Verificou-se também que ambas as amostras do IFA prednisona tratavam-se na mesma forma cristalina e que essa não sofreu transição durante o estudo, que uma correlação CIVIV não pode ser obtida e que A simulação da biodisponibilidade realizada para a prednisona utilizando o software GastroPlus TM foi bem sucedida comparada os resultados obtidos in vivo. / The solid dosage forms for oral use, especially tablets are the most used in therapy because they are easily adminis tered and have high productivity relatively low cost and to provide a more stable drug to the forms semi-solid net. However, a drug in solid form may change due to the action of various factors such as humidity, temperature, light and oxygen from the envir onment and the characteristics of the solid state of the active substance and the excipients used in the formulation. The instability of a drug, in alone or in a formulation can change various quality parameters such as aspect, content, dissolution and dis solution profile. The dissolution profile of a drug is a quality parameter that must be evaluated during the production and stability of solid oral dosage forms, for the same change during the storage period can change the amount of drug available for absorption, which may compromise the the bioavailability and therapeutic efficacy. In this study the dissolution profile of 20 mg prednisone tablets bioequivalent to the reference product and three test formulations were evaluated throughout the stability testing. During the study,prednisone tablets and the active pharmaceutical ingredient (API) prednisone,two different manufacturers were characterized with respect to their physical properties and physicochemical. The API was also evaluated for their permeability in Caco-2 cells. The data were used to develop a correlation study in vitro-in silico-vivo studies and develop in silico prediction of bioavailability. The results showed that the dissolution profiles of the drug from the tablets and the reference test batches did not remain equal throughout the study. It was also noted that both samples API prednisone treated in the same crystal form and that the transition has not suffered during the study, a correlation IVIVC can’t be obtained and bioavailability of simulation performed for prednisone using software GastroPlus TM was successful compared the results obtained in vivo.
16

Avaliação da biodisponibilidade de uma nova formulação de micofenolato mofetil e de um método para sua monitorização terapêutica / Assessment of the bioavailability of a new micophenolate mofetil formulation and a method for therapeutic monitoring

Paschoalina Romano 08 March 2007 (has links)
O Micofenolato Mofetil (MMF) é amplamente utilizado em transplantes de órgãos sólidos e tem como seu metabólito ativo o ácido micofenólico (MPA). A alta variabilidade intra e interindividual dos níveis plasmáticos de MPA em pacientes transplantados renais que recebem a mesma dose de MMF, a combinação com diferentes imunossupressores que afetam seu metabolismo e a oscilação destes níveis com o tempo decorrido após o transplante justificam a sua monitorização. Pequenas mudanças na dose de MMF podem comprometer a eficácia terapêutica. O objetivo deste trabalho foi avaliar a farmacocinética de duas formulações de MMF. Estudouse um ensaio para a dosagem de ácido micofenólico (MPA) plasmático (EMIT® 2000, Dade Behring) e a seguir, a biodisponibilidade da nova formulação de MMF disponibilizada por Strides Arcolab (MMF-SA), comparativamente ao CellCept® em pacientes transplantados renais estáveis. A metodologia de imunoensaio enzimático (EMIT) apresenta resultados relativamente mais elevados em relação à cromatografia líquida de alta resolução, devido à reação cruzada do metabólito acil glucoronídeo de MPA (AcMPAG) com o anticorpo presente no reagente. O método é capaz de detectar não só o MPA, mas também o seu metabólito ativo AcMPAG, o que pode representar uma vantagem. Comparamos o método EMIT com cromatografia líquida de alta resolução acoplada à espectrometria de massas (LC-MS/MS) e obtivemos r2 = 0,9612. O método apresentou: sensibilidade analítica de 0,02 ± 0,0016ug/mL; limite de detecção de 0,01 ± 0,0015ug/mL; linearidade de 14,58 ± 0,3300ug/mL; coeficientes de variação, intraensaio de 2,14% - 5,09% e interensaio de 4,18% - 5,02%. A estabilidade da amostra foi de 90 dias em temperatura de -20°C. Concluiu-se que a metodologia EMIT para dosagem de MPA é de fácil execução e apresenta boa precisão analítica. Participaram do estudo de biodisponibilidade, vinte e quatro pacientes adultos, transplantados renais, que já recebiam o CellCept® em combinação com Tacrolimus (n = 14), ciclosporina (n= 7) ou sem inibidores de calcineurina (n=3). Todos recebiam prednisona. As duas drogas foram administradas em esquema cruzado, com intervalo de uma semana entre as farmacocinéticas. Neste intervalo, os pacientes continuaram recebendo CellCept®. Foram analisadas as curvas farmacocinéticas de 12 horas para cada uma das duas formulações, nas mesmas doses equimolares. As médias ± SE das medidas de concentração máxima (Cmax) e da área sob a curva (AUC), para CellCept®, não foram estatisticamente diferentes das médias ± SE para MMF-SA (11,29 ± 1,35ug/mL versus 11,05 ± 1,08ug/mL e 49,11 ± 5,15ug.h/mL versus 47,59 ± 3,99 ug.h/mL), respectivamente. Da mesma forma, o intervalo de confiança 90% de MMF-SA / CellCept® para Cmax (93,57% - 121,73%) e para AUC 0-12h (93,75% - 108,90%) ficaram dentro do intervalo de bioequivalência (80% - 125%). Concluímos que CellCept® pode ser substituído com segurança pela formulação MMF-SA genérica em pacientes transplantados renais estáveis. / Mycophenolate mofetil (MMF) is largely used in solid organ transplantation. Mycophenolic Acid (MPA) is the active metabolite of MMF. The high intra and interpatients variability of the MPA plasma levels in transplant recipients under the same dose of MMF, the association with immunosuppressant drugs that change the MPA metabolism and pharmacokinetic parameters over time may cause impact in the optimal dose of MMF. The therapeutic monitoring of MPA may improve the efficacy and safety. The aim of this study was to: 1 -to validate the EMIT assay for MPA monitoring and 2: to assess the bioavailability of two MMF formulations. The performance of the EMIT® 2000 Dade Behring Mycophenolic acid enzimatic immunoassay was evaluated. There was a high correlation between the LC-MS/MS and EMIT (r2 = 0.9612). Because of the cross-reactivity of the antibody used in the EMIT assay with the active acyl glucuronide metabolite (AcMPAG), the EMIT concentrations are higher than those from high performance liquid chromatography (HPLC).The analytic sensitivity was 0.02 ± 0.0016ug/mL; detection limit 0.01 ± 0.0015ug/mL; linearity 14.58 ± 0.3300ug/mL. The CV of within-day precision was 2.14% - 5.09% and the CV of between-days precision was 4.18% - 5.02%. The sample stability was 90 days at - 20°C. The EMIT assay is easily performed and fulfills all the requirements for an assay. We studied the MMF formulation from Strides Arcolab (MMF-SA) and CellCept® in twenty-four adult, renal transplanted patients, receiving MMF (CellCept®), before the bioavailability study, combined with tacrolimus (n = 14), cyclosporine (n = 7) or without CNI (n = 3). All patients received prednisone. They had a 12 hours pharmacokinetics (PK) of total MPA measured after the same equimolar doses for the two formulations. The PK analysis revealed two mean PK curves that overlaid over each other. Mean ± SE of maximum concentration (Cmax) and area under the time-concentration curve (AUC) of CellCept® were not statistically different from the generic MMF-SA (11.29 ± 1.35 ug/mL vs 11.05 ± 1.05 ug/mL and 49.11 ± 5.15 ug.h/mL vs 47.59 ± 3.99 ug.h/mL, respectively). In the same way the MMF-SA/CellCept® 90% confidence interval for both: Cmax (93.57% -121.73%) and AUC0-12h (93.75% - 108.90%) was within the bioequivalence interval (80%-125%). In renal transplanted patients, CellCept® can be switched by the generic MMF formulation.

Page generated in 0.0669 seconds